• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 41
  • 10
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 120
  • 52
  • 52
  • 46
  • 37
  • 26
  • 26
  • 22
  • 16
  • 16
  • 16
  • 13
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Luminiscenční vlastnosti fosforů ve vysoce výkonných LED aplikacích / Luminescence properties of phosphors for highpower LED applications

Rejman, Martin January 2016 (has links)
For selected YAG:Ce sample the temperature dependent absorbtion and emission spectra were measured and used to simulate white LED behavior. Various CIE-xy dependencies were observed. Sample surface scaterring parameters were calibrated using a custom-made automated goniospektrometer, which provided measured data with fine accuracy. Finally, the measured data were used to construct a Geant4 simulation to optimize two light devices for output intensity and target CIE-xy coordinates. Powered by TCPDF (www.tcpdf.org)
22

Improving tau decay simulations for detecting tau neutrinos at IceCube / Förbättringar av simuleringar av tausönderfall för att detektera tauneutriner vid IceCube

Thor, Simon January 2024 (has links)
Tau neutrinos are one of the least understood elementary particles, as they are difficult to detect. One of the few detectors that can detect them is the IceCube neutrino observatory, located on the south pole. When tau neutrinos interact with a nucleus in the ice at IceCube, a tau lepton can form, which decays almost instantaneously. The decay products of the tau lepton will then emit light, which can be detected at IceCube. To gain a better understanding of tau neutrinos, it is therefore crucial to accurately simulate tau lepton decays. In this thesis, the tau lepton decays within the IceCube simulation framework are evaluated by comparing the simulations to TAUOLA, a high-precision tau decay simulation library, Through this work, several issues with the current simulations were discovered. Specifically, the polarization of the tau lepton is neglected, hadronic resonances are not implemented for tau decays, and several decay modes are missing. These issues result in an overestimate of the energy of the visible decay products, which means that the light emitted from the tau decay is dimmer in reality than what is predicted by the current IceCube simulations. To address this, TAUOLA was integrated into the IceCube simulations, thereby enabling high-precision tau decay simulations for future studies. / Tauneutriner är en av de allra minst studerade partiklarna på grund av att de är svåra att detektera. En av få detektorer som han observera tau neutriner är neutrinoteleskopet IceCube vid sydpolen. När tauneutriner interagerar med isen kan en taulepton skapas, som snabbt sönderfaller. De partiklar som bildas vid sönderfallet avger ljus som kan mätas i IceCube. För att kunna studera tauneutriner är det därför fundamentalt att simulera korrekta och noggranna tausönderfall. Under detta examensarbete jämfördes IceCubes simuleringar av tausönderfall mot mjukvarubiblioteket TAUOLA, som är ämnat för högprecisionssimuleringar av tausönderfall. Genom detta upptäcktes ett flertal problem med IceCubes simuleringar: ingen hänsyn tas till polariseringen av tauleptonen, hadroniska resonanser är inte implementerade, och det finns ett flertal sätt som tauleptonen kan sönderfalla på som inte är implementerade. Dessa problem leder till att energin hos de observerbara partiklarna som produceras vid sönderfallet överskattas, vilket innebär att ljuset som avges i verkligheten är mindre än vad simuleringarna förutspår. För att lösa dessa problem integrerades TAUOLA i IceCubes simuleringsramverk, vilket möjliggör precisa tausönderfallssimuleringar för framtida analyser inom IceCube.
23

Extension et validation de l’outil Geant4 dans le cadre du projet Geant4-DNA pour la prédiction des dommages biologiques radio-induits à l’échelle cellulaire

Tran, Ngoc Hoang 24 September 2012 (has links)
L’étude des effets biologiques des radiations ionisantes à l’échelle de la cellule individuelle et en particulier sur l’ADN du noyau cellulaire reste un enjeu majeur de la radiobiologie actuelle. L’objectif principal des recherches actuelles est de déterminer quels peuvent être les effets biologiques délétères des radiations ionisantes pour la santé humaine, en particulier dans le domaine des faibles doses de radiation. Afin d’étudier précisément la réponse des cellules aux radiations ionisantes, de nombreuses études expérimentales des effets des radiations ionisantes sur les cellules, tissus et organismes biologiques aux basses énergies ont accumulées de grandes quantités de données de qualité sur la réponse de cellules aux radiations. Il existe également de nombreux modèles semi-empiriques de survie cellulaire qui incorporent des paramètres biologiques et physiques. En parallèle, des stochastiques basées sur la technique « Monte Carlo » pour modéliser les processus élémentaires en physique, chimie et biologie sont en cours de développement. L’outil Geant4 développé dès 1993 (CERN et KEK) en utilisant des techniques informatiques de dernière génération (C++) permet à l’utilisateur de construire une simulation complète grâce à de nombreuses fonctionnalités : formes géométriques, matériaux, particules élémentaires, processus physiques électromagnétiques et hadroniques, visualisation, analyse de données, interactivité et extensibilité… Cependant, Geant4 présente un certain nombre de limitations pour la simulation des effets biologiques des radiations ionisants à l’échelle subcellulaire : les modèles standard ne prennent pas compte le technique « pas-à-pas », les modèles physique sont limités à basse énergie, il n’a pas des descriptions des cibles moléculaires et Geant4 n’est pas capable de simuler les étapes physico-chimique et chimique nécessaire pour déterminer l’oxydation des bases et les éventuelles cassures d’ADN.Dans ce contexte, le projet Geant4-DNA propose d’étendre Geant4 afin de modéliser les interactions des radiations ionisantes à l’échelle de la cellule biologique et la molécule d’ADN et aux basses énergies. Au cours du travail de thèse, j’ai tout d’abord validé les modèles physiques en comparant les résultats de simulation à une grande collection de données expérimentales disponibles dans la littérature. L’accord entre les valeurs de sections efficaces totales et différentielles et les mesures expérimentales a été quantifié à l’aide du test statistique Kolmogorov-Smirnov. J’ai par la suite amélioré les classes des processus de diffusion élastique des électrons et travailler sur les calculs théoriques du modèle de diffusion élastique des protons et des alphas dans l’eau liquide auparavant inexistant dans Geant4-DNA. J’ai effectué une combinaison des processus multi-échelles des modèles de Geant4-DNA (à l’échelle microscopique) avec les modèles électromagnétiques disponibles dans l’outil Geant4 (les processus d’interaction des photons et autres modèles de Geant4). A la fin de mon travail, j’ai participé à l’estimation des performances de Geant4-DNA pour la dosimétrie dans des géométries de petite taille (jusqu’à l’échelle du nanomètre) dans l’eau liquide à l’aide des distributions « Dose Point Kernel ». J’ai ensuite calculé les fréquences de dépôts d’énergie dans des petits cylindres de dimensions nanométriques correspondant à des cibles biologiques et des modèles de noyau cellulaire humain simplifié pour l’estimation des cassures directes simple et double. Mon travail de thèse a fournit les premiers résultats de Geant4-DNA pour la prédiction de cassure de brin d’ADN combinant physique et géométries à l’échelle de l’ADN. Enfin, nous avons développé des classes de processus et modèles basés sur l’approche CTMC-COB (Classical Trajetory Monte Carlo avec critère d’Over Barrier) spécifique aux bases de la molécule d’ADN et à l’eau liquide. / A large experimental and modeling activity is currently taking place, aimed at better understanding the biological effects of ionizing radiation at the molecular scales. Considerable amounts of experimental data have been accumulated over the past decades in order to measure quantities such as macroscopic cellular survival curves and DNA strand damages after irradiation. In parallel, computer codes have been proposed to use a stochastic approach based on Monte Carlo technique to model physical interaction in the irradiated medium. The Geant4 toolkit uses the object-oriented technology (C++) to describing particle-matter interactions, such as bio-medical physics and space physics, from sub-micrometer cells up to planetary scales. Geant4-DNA project is included in the Geant4 toolkit and benefits from the easy accessibility of the Geant4 code for the development of a computing platform allowing estimation effects of ionizing radiations. In my thesis, firstly, I have contributed in the project the validation of various models with the experimental data collections extracted from the recent literature. A good agreement between total and differential cross section values corresponding to each available Geant4-DNA model and experimental data is validated by Kolmogorov-Smirnov testing. Secondly, I have improved elastic scattering process and working on the calculation of the DDCS for proton elastic scattering in water in the Geant4-DNA. In addition, I have combined Geant4 electromagnetic processes with the Geant4-DNA. This combination brought additional Geant4 simulation capabilities in complement of the possibility to combine Geant4-DNA models with other Geant4 electromagnetic models at different sizes and energy scales in a single simulation application. Finally, we have presented the usage of Geant4-DNA physics processes in nanometer-size targets fully implemented in a single Geant4 application. The frequencies of the deposited energy and number of direct DNA single strand break and double strand break in the simplified nucleus model are compared with other codes results and with a collection of experimental data on direct DNA dimensions on plasmid DNA. Furthermore I have implemented in Geant4-DNA theoretical cross sections of physics processes based on a Classical Trajectory Monte Carlo (CTMC) approach for modeling the detailed transport of protons and neutral hydrogen atoms in liquid water and in DNA nucleobases.
24

Measurement of the positron polarization at an helical undulator based positron source for the International Linear Collider ILC

Laihem, Karim 25 August 2009 (has links)
Als Basis der Positronenquelle zur Erzeugung polarisierter Positronen bei einem zukuunftigen internationalen Linearkollider ist ein helikaler Undulator vorgesehen. Das E-166 Experiment testete diese Methode unter Benutzung eines ein Meter langen, kurzperiodischen, gepulsten helikalen Undulators im Final Focus Test Beam (FFTB) am SLAC. Ein 46.6 GeV Elektronenstrahl mit geringer Emittanz wurde durch diesen Undulator gefuehrt und erzeugte zirkular polarisierte Photonen mit einer Energie bis zu ungefaehr 8 MeV. Diese wiederum konvertierten in einem relativ duennen Target zu longitudinal polarisierten Positronen. Die Polarisation der Positronen wurde bei 5 verschieden Positronenergien gemessen. Zusaetzlich ist die Polarisation von Elektronen fuer einen Energiepunkt gemessen worden. Um die gemessenen Asymmetrien mit den Erwartungen vergleichen zu koennen, waren detaillierte Simulationen noetig. Dies erforderte die Erweiterung von von GEANT4 um die wichtigsten polarisationsabhaengigen Wechselwirkungen von Elektronen, Positronen und Photonen mit Materie. Die gemessene Positronpolarisation stimmt mit den Erwartungen ueberein und betraegt fuer den Energiepunkt mit der hoechsten Polarisation von 6 MeV mehr als 80 prozent. / A helical undulator based polarized positron source is forseen at a future International Linear Collider. The E-166 experiment has tested this scheme using a one meter long, short-period, pulsed helical undulator installed in the Final Focus Test Beam (FFTB) at SLAC. A low-emittance 46.6 GeV electron beam passing through this undulator generated circularly polarized photons with energies up to about 8 MeV. The generated photons of several MeV with circular polarization are then converted in a relatively thin target to generate longitudinally polarized positrons. Measurements of the positron polarization have been performed at 5 different energies of the positrons. In addition electron polarization has been determined for one energy point. For a comparison of the measured asymmetries with the expectations detailed simulations were necessary. This required upgrading GEANT4 to include the dominant polarization dependent interactions of electrons, positrons and photons in matter. The measured polarization of the positrons agrees with the expectations and is for the energy point with the highest polarization at 6 MeV about 80 percent.
25

Etude de la production, de la propagation et de la focalisation d'un faisceau d'électrons impulsionnel intense / Study of the production, the propagation and the focusing of an electron beam

Pepitone, Kévin 08 October 2014 (has links)
Le faisceau d’électrons (500 keV, 30 kA, 100 ns) produit par le générateur RKA (Relativistic Klystron Amplifier) est utilisé pour étudier des matériaux soumis à des chocs de basse fluence (< 10 cal/cm²). Leur réponse dépend des caractéristiques du faisceau, principalement en termes d’homogénéité spatiale lors de l’impact. Dans ce but, nous avons utilisé des diagnostics électriques et un diagnostic optique basé sur l’émission Cerenkov. Les photons visibles produits sont détectables par des caméras rapides. Nous avons ainsi pu étudier l’homogénéité du faisceau émis dans la diode sous vide en fonction des matériaux utilisés pour la cathode et pour l’anode, mais aussi pu suivre sa propagation dans une enceinte contenant un gaz à basse pression.Chaque partie de l’installation a été optimisée lors de cette thèse. Nous avons constaté qu’une cathode en velours avec des fibres bien ordonnées était le meilleur émetteur. Une anode d’une dizaine de micromètres d’épaisseur permet de diffuser le faisceau avant qu’il n’impacte la cible, améliorant encore son homogénéité. Ces travaux sur la diode ont été complétés par une étude de la propagation du faisceau dans une enceinte remplie d’air ou d’argon à différentes pressions, avec ou sans focalisation produite par un champ magnétique externe. D’après les résultats expérimentaux, un faisceau d’électrons de 400 keV, 4,2 kA peut être propagé, avec un rayon constant, dans 0,7 mbar d’argon. Enfin, pour interpréter les expériences, des simulations ont été réalisées à l’aide du code Monte Carlo Geant4 pour calculer l’interaction du faisceau avec la cible Cerenkov et l’anode. Au niveau de l’émission et du transport du faisceau, le bon accord obtenu avec les prédictions du code PIC Magic permet d’estimer les distributions des électrons par la simulation et d’initialiser correctement les calculs de réponse des matériaux. / The electron beam (500 keV, 30 kA, 100 ns) of the RKA (Relativistic Klystron Amplifier) generator is used to study materials under shocks at low fluences (< 10 cal/cm²). Their response depends on the beam characteristics at the impact location, mainly in terms of spatial homogeneity. We have used electrical diagnostics as well as an optical diagnostics where the visible photons produced by Cerenkov emission in a silica target are collected by fast cameras. Beam homogeneity has been studied in the vacuum diode as a function of the materials used for the cathode and the anode. Beam propagation and focusing in a chamber filled with a low-pressure gas has also been investigated.Each part of the installation has been optimized during this work. We found that, among the tested materials, a velvet cathode with well-aligned fibers is the best emitter. An anode of thickness about ten micrometers improves the beam homogeneity by scattering of electrons. Next, we focused on beam propagation and focusing in the chamber. For example, a 400 keV, 4.2 kA electron beam can be propagated at constant radius in argon at 0.7 mbar. We performed simulations with the Monte Carlo code Geant4 in order to compute the beam interaction with the Cerenkov target as well as with the anode. Beam emission and propagation were simulated with the PIC code Magic. The good agreement with the experimental results allows us to estimate the electron distributions at any position along the beam path in order to initialize correctly the computation of the beam-material interaction.
26

Evaluation de la dose déposée par des faisceaux d'électrons en radiothérapie dans des fantômes voxelisés en utilisant la plateforme de simulation Monte Carlo GATE fondée sur GEANT4 dans un environnement de grille / Evaluation of the dose deposited by electron beams in radiotherapy in voxelized phantoms using the Monte Carlo GATE simulation platform based on GEANT4 in a grid environment

Perrot, Yann 08 December 2011 (has links)
La planification de traitement en radiothérapie nécessite un calcul précis de la dose délivrée au patient. La méthode la plus fiable pour y parvenir est la simulation du transport des particules par technique Monte Carlo. Cette thèse constitue la première étude concernant la validation de la plateforme de simulation Monte Carlo GATE (GEANT4 Application for Tomographic Emission), basée sur les librairies de GEANT4 (GEometry ANd Tracking), pour le calcul de la dose absorbée déposée par des faisceaux d’électrons. L’objectif de cette thèse est de montrer que GATE/GEANT4 est capable d’atteindre le niveau d’exigences requis pour le calcul de la dose absorbée lors d’une planification de traitement, dans des situations où les algorithmes analytiques, actuellement utilisés dans les services de radiothérapie, n’atteignent pas un niveau de précision satisfaisant. L’enjeu est de prouver que GATE/GEANT4 est adapté pour la planification de traitement utilisant des électrons et capable de rivaliser avec d’autres codes Monte Carlo reconnus. Cet enjeu a été démontré par la simulation avec GATE/GEANT4 de faisceaux et des sources d’électrons réalistes utilisées en radiothérapie externe ou en radiothérapie moléculaire et la production de distributions de dose absorbée en accord avec les mesures expérimentales et avec d’autres codes Monte Carlo de référence pour la physique médicale. Par ailleurs, des recommandations quant à l’utilisation des paramètres de simulation à fixer, assurant un calcul de la distribution de dose absorbée satisfaisant les spécifications en radiothérapie, sont proposées. / Radiation therapy treatment planning requires accurate determination of absorbed dose in the patient. Monte Carlo simulation is the most accurate method for solving the transport problem of particles in matter. This thesis is the first study dealing with the validation of the Monte Carlo simulation plateform GATE (GEANT4 Application for Tomographic Emission), based on GEANT4 (GEometry And Tracking) libraries, for the computation of absorbed dose deposited by electron beams. This thesis aims at demonstrating that GATE/GEANT4 calculations are able to reach treatment planning requirements in situations where analatycal algorithms are not satisfactory. The goal is to prove that GATE/GEANT4 is useful for treatment planning using electrons and competes with well validated Monte Carlo codes. This is demonstrated by the simulations with GATE/GEANT4 of realistic electron beams and electron sources used for external radiation therapy or targeted radiation therapy. The computed absorbed dose distributions are in agreement with experimental measurements and/or calculations from other Monte Carlo codes. Furthermore, guidelines are proposed to fix the physics parameters of the GATE/GEANT4 simulations in order to ensure the accuracy of absorbed dose calculations according to radiation therapy requirements.
27

Design study of a Compton camera for prompts-gamma imaging during ion beam therapy / Conception d'une caméra Compton pour le contrôle en ligne en hadronthérapie

Richard, Marie-Hélène 04 September 2012 (has links)
L'hadronthérapie est une technique innovante de radiothérapie par ions carbone ou protons visant à améliorer les traitements actuels. La précision balistique accrue renforce la nécessité d'un contrôle du dépôt de dose, si possible en temps réel. Une manière de réaliser ce contrôle est de détecter avec une caméra Compton le gamma prompt émis lors des fragmentations nucléaires pendant l'irradiation du patient. Dans un premier temps, la géométrie de deux types de caméra Compton (double diffusion puis simple diffusion) a été optimisée par simulation Monte Carlo. Cette optimisation a été réalisée en étudiant la réponse des caméras à une source ponctuelle de photons avec un spectre en énergie réaliste. La réponse de la caméra optimisée à l'irradiation d'un fantôme d'eau par un faisceau d'ions carbone ou de protons a ensuite été simulée. Ces simulations ont tout d'abord été confrontées à des mesures effectuées avec un prototype de taille réduite. Ces mesures ont ensuite été utilisées pour évaluer les taux de comptage dans les détecteurs attendus en conditions cliniques. Dans la configuration actuelle de la caméra, ces taux sont élevés et les phénomènes d'empilement risquent d'être problématiques. Enfin, il est démontré que le dispositif étudié est sensible à un déplacement du pic de Bragg de plus ou moins 5 mm malgré les problèmes de coïncidences fortuites et malgré le bruit introduit par l'algorithme de reconstruction utilisé. / Ion beam therapy is an innovative radiotherapy technique using mainly carbon ion and proton irradiations. Its aim is to improve the current treatment modalities. Because of the sharpness of the dose distributions, a control of the dose if possible in real time is highly desirable. A possibility is to detect the prompt gamma rays emitted subsequently to the nuclear fragmentations occurring during the treatment of the patient. In a first time two different Compton cameras (double and single scattering) have been optimised by means of Monte Carlo simulations. The response of the camera to a photon point source with a realistic energy spectrum was studied. Then, the response of the camera to the irradiation of a water phantom by a proton beam was simulated. It was first compared with measurement performed with small-size detectors. Then, using the previous measurements, we evaluated the counting rates expected in clinical conditions. In the current set-up of the camera, these counting rates are pretty high. Pile up and random coincidences will be problematic. Finally we demonstrate that the detection system is capable to detect a longitudinal shift in the Bragg peak of +or- 5 mm, even with the current reconstruction algorithm.
28

De l’impact à long terme des radiations ionisantes sur les systèmes vivants / The long term impact of ionising radiation on living systems

Lampe, Nathanael 05 May 2017 (has links)
La vie sur Terre s’est adaptée à un environnement où il y a un faible et persistent bruit de fond radiatif qui interagit avec les cellules. Loin des effets clairement nocifs des radiations à haute dose, il est difficile d’évaluer et de comprendre les impacts des faibles doses de la radioactivité naturelle sur les systèmes vivants. Nous avons tenté d’étudier si le bruit de fond radiatif est un facteur important dans l’évolution, en menant des expériences évolutives identiques avec Escherichia coli au Laboratoire de Physique Corpusculaire de Clermont-Ferrand, et au Laboratoire Souterrain de Modane. Malgré une différence d’un facteur 7,3 entre les taux d’interaction des rayonnements ionisants avec les cellules dans les deux laboratoires, aucune différence significative n’a pu être trouvée dans le fitness compétitif des populations cellulaires évoluées dans chaque laboratoire. Par simulation, nous avons montré que le taux d’interaction entre le bruit de fond radiatif et E. coli est cent fois plus faible que le taux de mutations d’origine endémique, ce qui renforce l’hypothèse que les radiations naturelles ont peu d’effet sur l’évolution. Dans le cadre du projet Geant4-DNA, nous avons développé une application complète de simulation mécanistique des dommages radio-induits à l’ADN, afin d’explorer davantage cette hypothèse. Avec cette application, on a irradié un modèle du génome d’E. coli, montrant que pour l’irradiation par des électrons d’énergies > 10 keV, le rendement des cassures double brin est de 0,006 – 0,010 CDB Gy-1 Mbp-1, selon le modèle de piégeage des radicaux chimiques. Ce résultat est en accord avec des données expérimentales, et souligne plus encore que les radiations ionisantes d’origine naturelle n’ont qu’une contribution mineure aux mutations responsables de l’évolution. / All life on earth has adapted to an environment where there is a small, persistent, radiation background interacting with cells. Unlike evaluating the clearly harmful effects of high radiation doses, understanding the effects of this low persistent radiation dose on living systems is incredibly difficult. We have attempted to study whether background radiation is an important factor in evolution by conducting identical evolution experiments with Escherichia coli in the Clermont-Ferrand Particle Physics Laboratory and the Modane Underground Laboratory. Despite a 7.3 fold difference in the rate of interactions between the radiation background and cells between the two environments, no significant difference was found in the competitive fitness of the cell populations grown at each location. Using simulations, we showed that the rate at which ionising radiation interacts with cells is one hundred times less frequent than E. coli’s mutation rate in our experimental conditions, supporting the contention that natural radiation has no strong evolutionary effect. To further support this conclusion, we developed a mechanistic simulation for DNA damage as part of the Geant4-DNA project. Using this application, we irradiated a model of an E. coli genome, showing that for electron irradiation > 10 keV, the double strand break yield can be reasonably estimated to be between 0.006 – 0.010 DSB Gy-1 Mbp-1, depending upon the modelling of radical scavenging. This is in agreement with experimental data, further highlighting the small role natural ionising radation plays as a cause of mutations.
29

Imagerie tomograpbique d'un volcan à l'aide des muons atmosphériques / Tomographic imaging of volcanoes using atmospheric muons

Béné, Samuel 22 December 2016 (has links)
Les muons atmosphériques sont des particules élémentaires créées lors de l’interaction des rayons cosmiques de haute énergie avec les atomes de la haute atmosphère. Leur capacité à traverser de grandes quantités de matière et leur abondance au niveau du sol permet d’utiliser leur flux comme support à la radiographie de grands objets. Cette technique, la muographie, possède notamment comme sujet d’application possible l’étude de volcans. La collaboration Tomuvol, au sein de laquelle cette thèse s’est déroulée, vise à mettre au point un détecteur et les techniques d’analyse permettant la réalisation d’une telle mesure avec comme sujet d’étude un volcan auvergnat : le Puy de Dôme. Ce manuscrit présente les contributions à ce travail du point de vue instrumental tout d’abord, avec la calibration et l’optimisation des performances des chambres GRPC utilisées pour la mesure. Les performances du détecteur lors des diverses campagnes de prise de données qui se sont déroulées au pied du Puy de Dôme sont également résumées. Dans une deuxième partie, l’accent est porté sur l’analyse physique des données obtenues avec, dans un premier temps, la description des travaux de simulation Monte-Carlo mis en œuvre avec le logiciel GEANT4. Puis, une technique d’estimation du flux transmis de muons atmosphériques à l’aide d’une méthode de type noyaux est présentée, et la carte de densité estimée du Puy de Dôme qui en découle est comparée aux résultats issus de techniques géophysiques. / Atmospheric muons are elementary particles originating from the interaction of high energy cosmic rays with atoms in the upper atmosphere. Their ability to travel through a large amount of matter and their abundance at ground level allows for their flux to be used as a probe for the radiography of big objects. This technique, muography, can in particular be of interest for the study of volcanoes. The Tomuvol collaboration, within which this thesis took place, aims at developing a detector and analysis techniques allowing to perform such a measurment, using a volcano from Auvergne as a case study : the Puy de Dôme. This document describes the author’s contributions to this work, focusing on the intrumentation aspect first, with the calibration and optimisation of the GRPC chambers used to perform the measurment. The performances of the detector during the various campaigns of data acquisition at the base of the Puy de Dôme are also sumed up. A second part is dedicated to the physical analysis of the data with, firstly, the description of the Monte-Carlo simulations that were developed using the GEANT4 software. Then, a kernel-like estimation method of the transmitted flux of atmospheric muons is described, and the density map of the Puy de Dôme thus obtained is compared to results coming from geophysical techniques.
30

Modes d’exposition au xénon-133 dans un bâtiment réacteur / Exposure mode study to xenon-133 in a reactor building

Perier, Aurélien 14 October 2014 (has links)
Le travail décrit dans cette thèse porte sur l’évaluation du mode d’exposition externe et interne au xénon-133. Ce radionucléide est un des principaux produits de fission du combustible des réacteurs nucléaires. En cas de défaut de gaine combustible, le xénon-133 peut potentiellement exposer le personnel lors de ses interventions dans le bâtiment réacteur. En dosimétrie, les simulations Monte-Carlo sont des outils adaptés pour simuler le transport des rayonnements ionisants dans la matière. A partir des critères de radioprotection actuels, nous avons développé de nouvelles méthodes afin d’améliorer notre compréhension de l’exposition externe et interne auxénon-133 à l’intérieur d’un bâtiment réacteur. Ces nouvelles approches sont basées sur l’utilisation d’un fantôme anthropomorphe, d’une géométrie réaliste de bâtiment réacteur, de simulations Monte-Carlo GEANT4 et de modèles en compartiments. L’exposition externe dans un bâtiment réacteur a été menée en retenant un scénario d’exposition réaliste et conservatif. Nous avons quantifié le débit de dose efficace et le débit de dose équivalente au cristallin. L’exposition interne se produit lorsque le xénon-133 est inhalé. Les poumons sont les premiers organes exposés par l’inhalation du xénon-133, leur débit de dose équivalente a été quantifié. Un modèle biocinétique a été utilisé pour évaluer l’exposition interne au xénon-133. Cette thèse a permis de quantifier les grandeurs dosimétriques liées aux modes d’exposition externe et interne au xénon-133, d’étudier l’impact des changements de limites dosimétriques introduits par la Commission Internationale de Radioprotection prochainement retranscrits dans la réglementation française, et de comprendre la cinétique du xénon-133 dans le corps humain. Nous avons montré que les grandeurs dosimétriques sont nettement inférieures aux limites dosimétriques de la réglementation actuelle et future. / The work described in this thesis focuses on the external and internal dose assessment to xenon-133. During the nuclear reactor operation, fission products and radioactive inert gases, as ¹³³Xe, are generated and might be responsible for the exposure of workers incase of clad defect.Particle Monte Carlo transport code is adapted inradioprotection to quantify dosimetric quantities.The study of exposure to xenon-133 is conducted byusing Monte-Carlo simulations based on GEANT4, ananthropomorphic phantom, a realistic geometry of thereactor building, and compartmental models.The external exposure inside a reactor building isconducted with a realistic and conservative exposurescenario. The effective dose rate and the eye lensequivalent dose rate are determined by Monte-Carlosimulations. Due to the particular emission spectrum ofxenon-133, the equivalent dose rate to the lens of eyesis discussed in the light of expected new eye doselimits.The internal exposure occurs while xenon-133 isinhaled. The lungs are firstly exposed by inhalation, andtheir equivalent dose rate is obtained by Monte-Carlosimulations. A biokinetic model is used to evaluate theinternal exposure to xenon-133.This thesis gives us a better understanding to thedosimetric quantities related to external and internalexposure to xenon-133. Moreover the impacts of thedosimetric changes are studied on the current andfuture dosimetric limits. The dosimetric quantities arelower than the current and future dosimetric limits.

Page generated in 0.029 seconds