• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 41
  • 10
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 120
  • 52
  • 52
  • 46
  • 37
  • 26
  • 26
  • 22
  • 16
  • 16
  • 16
  • 13
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Simulation de l'imagerie à 3γ avec un télescope Compton au xénon liquide / Simulation of the 3γ imaging using liquid xenon Compton telescope

Mohamad Hadi, Abdul Fattah 17 June 2013 (has links)
L’imagerie 3γ est une technique innovante d’imagerie médicale nucléaire qui est étudiée au laboratoire SUBATECH. Elle repose sur la localisation tridimensionnelle d’un radioisotope émetteur (β+, γ), le 44Sc, à l’aide d’un télescope Compton au xénon liquide. Le lieu de désintégration de ce radioisotope est obtenu par l’intersection de la ligne de réponse, construite à partir de la détection des deux photons de 511 keV issus de l’annihilation d’un positron, et du cône déterminé à partir du troisième photon. Un prototype de petite dimension XEMIS1 (XEnon Medical Imaging System) a été développé afin de faire la preuve expérimentale de la faisabilité de l’imagerie à 3γ. Les résultats de ce prototype sont très promoteurs en terme de résolution en énergie, de pureté du xénon liquide et de faible bruit électronique. La simulation Monte Carlo est un outil indispensable pour accompagner la R&D et évaluer les performances de la nouvelle technique d’imagerie proposée. Les travaux rapportés dans cette thèse concernent le développement de la simulation du système d’imagerie 3γ avec GATE (Geant4 Application for Tomographic Emission). De nouvelles fonctionnalités ont été implémentées dans GATE afin de simuler un détecteur de type TPC (Time Projection Chamber). Nous avons effectué une simulation du prototype XEMIS1 et obtenu des résultats en bon accord avec nos données expérimentales. La prochaine étape du projet consiste à construire une caméra cylindrique au xénon liquide pour l’imagerie du petit animal. Les résultats des simulations de cette caméra présentés dans cette thèse montrent la possibilité de localiser chaque désintégration le long de la ligne de réponse avec une très bonne précision et une bonne sensibilité de détection. Des premières images de fantômes simples, réalisées évènements par événements, et après reconstruction tomographiques ont également présentées. / Nuclear medical 3γ imaging is an innovative technique which is studied at the SUBATECH laboratory. It isbased on the three-dimensional localization of a (β+, γ) radioisotope emitter, the 44Sc, by using a liquid xenon Compton telescope. The position of the disintegration of this radioisotope is obtained by the intersection of the line of response, built by the detection of two 511 keVphotons from the annihilation of a positron, and the cone determined by the third photon. A small prototype XEMIS1 (XEnon Medical Imaging System) was developed to demonstrate experimentally the feasibility of 3γ imaging. The results of this prototype are quite encouraging in terms of energy resolution, purity of liquid xenon and electronic noise. The Monte Carlo simulation is an indispensable tool to support the R&D and to evaluate the new proposed technique of imaging ; this thesis work is to develop the simulation of 3γ imaging system by using GATE (Geant4 Application for Tomographic Emission). New functionalities have been added to GATE to simulate a TPC (Time Projection Chamber) detector. We performed a simulation of XEMIS1 prototype and obtained results in good agreement with our experimental data. The next step of the project is to build a full liquid xenon cylindrical camera for the small animal imaging. The results presented in this thesis of the simulations of this camera demonstrate the ability to locate every decayalong the line of response with very good accuracy and good detection sensitivity. The first direct images of simple phantoms, realized event by event, and after tomographic reconstruction are also presented.
32

Simulação com o código GEANT4 de medida de espessura de revestimento metálico em metal por XRF / GEANT4 simulation of measure thickness of metallic coating on metal by XRF

Ievgeniia Ievsieieva 17 September 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nesta dissertação são apresentados resultados de simulações Monte Carlo de fluorescência de raios X (XRF), utilizando o programa GEANT4, para medidas de espessura de revestimento metálico (Ni e Zn) em base metálica (Fe). As simulações foram feitas para dois tamanhos de espessura para cada metal de revestimento, (5μm e 10μm), com passos de 0,1 μm e 0,001 μm e com 106 histórias. No cálculo da espessura do revestimento foram feitas as aproximações de feixe de raios X monoenegético, com a análise da transmissão apenas da energia do K-alfa e para uma geometria compatível com um sistema real de medição (ARTAX-200). Os resultados mostraram a eficiência da metodologia de simulação e do cálculo da espessura do revestimento, o que permitirá futuros cálculos, inclusive para multirevestimentos metálicos em base metálica. / This dissertation is presented results of x-ray fluorescence (XRF) Monte Carlo simulations) using GEANT4 for metallic coating (Ni and Zn) thickness determination on metallic base (Fe). The simulations were made for two values of coating thickness for each covering (5 μm and 10 μm), with steps of 0.1 μm and 0.001 μm, and with 106 stories. The monoenergetic x-ray approach was used assuming the transmission of only K-alpha line. The experiment and geometry was similar to the real system of measurement (ARTAX-200 ). The results showed the efficiency of the simulation methodology, as well as the ability to measure the thickness of coating by XRF. Thus, a continuation of this study for multilayer metal coating could be promising.
33

Simulação com o código GEANT4 de medida de espessura de revestimento metálico em metal por XRF / GEANT4 simulation of measure thickness of metallic coating on metal by XRF

Ievgeniia Ievsieieva 17 September 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nesta dissertação são apresentados resultados de simulações Monte Carlo de fluorescência de raios X (XRF), utilizando o programa GEANT4, para medidas de espessura de revestimento metálico (Ni e Zn) em base metálica (Fe). As simulações foram feitas para dois tamanhos de espessura para cada metal de revestimento, (5μm e 10μm), com passos de 0,1 μm e 0,001 μm e com 106 histórias. No cálculo da espessura do revestimento foram feitas as aproximações de feixe de raios X monoenegético, com a análise da transmissão apenas da energia do K-alfa e para uma geometria compatível com um sistema real de medição (ARTAX-200). Os resultados mostraram a eficiência da metodologia de simulação e do cálculo da espessura do revestimento, o que permitirá futuros cálculos, inclusive para multirevestimentos metálicos em base metálica. / This dissertation is presented results of x-ray fluorescence (XRF) Monte Carlo simulations) using GEANT4 for metallic coating (Ni and Zn) thickness determination on metallic base (Fe). The simulations were made for two values of coating thickness for each covering (5 μm and 10 μm), with steps of 0.1 μm and 0.001 μm, and with 106 stories. The monoenergetic x-ray approach was used assuming the transmission of only K-alpha line. The experiment and geometry was similar to the real system of measurement (ARTAX-200 ). The results showed the efficiency of the simulation methodology, as well as the ability to measure the thickness of coating by XRF. Thus, a continuation of this study for multilayer metal coating could be promising.
34

Études théoriques et expérimentales des effets singuliers induits par les muons atmosphériques sur les technologies numériques d’échelle nanométrique / Theoretical and experimental studies of the Single Event Effect induced by atmospheric muons on numerical technologies of nanometric scales

Li Cavoli, Pierre 13 December 2016 (has links)
Cette étude s’inscrit dans le domaine de la microélectronique. Elle consiste à étudier l’impact de la morphologie 3D du dépôt d’énergie sur la modélisation des événements singuliers (SEE) induits par les muons atmosphériques. La démarche a consisté dans un premier temps à modéliser le dépôt d’énergie induits par des protons dans des volumes nanométriques. Pour cela, le code Monte-Carlo GEANT4 a permis de simuler et de stocker dans une base de données, les caractéristiques des traces des dépôts d’énergie des protons. Une fois la démarche validée pour les protons, des simulations du dépôt d’énergie induit par des muons ont été réalisées. Une caméra CCD a été utilisée afin de réaliser des mesures de l’environnement radiatif atmosphérique et de contraindre la modélisation des dépôts d’énergie induits par les muons. Cette étude met en évidence et quantifie l’apport de considérer la distribution radiale du dépôt d’énergie induit par des protons pour des volumes nanométriques, dans les calculs de prédiction des SEE. En revanche, l’étude montre que la considération de la distribution radiale du dépôt d’énergie induit par des muons dans des volumes nanométriques a un impact négligeable sur la modélisation des SEE. Il serait intéressant de réaliser des mesures du dépôt d’énergie induit par des muons dans des technologies nanométriques sous accélérateur. Cela permettrait d’apporter des données expérimentales encore inexistantes, nécessaires au développement de nouveaux modèles physiques plus précis sur la modélisationdu dépôt d’énergie induit par des muons. / This study concerns the domain of the microelectronics. It consists in the studyof the impact of the 3D morphology of the energy deposit on the Single EventEffect (SEE) modeling, induced by atmospheric muons. Over a first phase, theapproach has consisted in the modeling of the energy deposit induced by protonsin nanometric volumes. For that purpose the use of the Monte Carlo code GEANT4has allowed to simulate and stock in a database the tracks characteristics of theenergy deposit induced by protons. Once the approach validated for the protons,simulations of the energy deposit induced by muons have been realized. A CCDcamera has been used in order to measure the radiative atmospheric environmentand to constrain the modeling of the energy deposit induced by muons. This studyhighlights and quantify the contribution of the radial distribution of the energydeposit incuced by protons in nanometric volumes for the SEE prediction. On theother hand, the study shows that the contribution of the radial distribution of theenergy deposit induced by muons in nanometric volumes has a negligeable impacton the SEE modeling. It will be interesting to realize measurements of the energydeposit induced by muons in nanometric technologies under accelerator. This willallow to bring experimental data still nonexistant necessary to the developpmentof new physical models more accurate on the modelization of the energy depositinduced by muons.
35

Mesure de la dose physique par lms radiochromiques et simulation Monte Carlo pour l'hadronthérapie / Dose measurement using radiochromic lms and Monte Carlo simulation for hadrontherapy

Zahra, Nabil 25 June 2010 (has links)
En raison des forts gradients de dose générés par les interactions des particules avec la matière, les traitements par hadronthérapie nécessitent un contrôle très précis de la dose délivrée au patient. Les codes Monte Carlo représentent des outils indispensables dans la validation des systèmes de planification de traitement utilisé en clinique. Nous nous intéressons dans cette thèse au calcul de la dose physique à l'aide des simulations Monte Carlo Geant4/Gate. Nous étudions l'ajustement de plusieurs paramètres qui peuvent influencer la précision du calcul de dose requise en clinique (2%, 2mm) pour un faisceau d'ions carbone de 300 MeV/u dans l'eau. Ces paramètres sont : le seuil de production des particules secondaires et la taille maximale d'un segment de la trace de particule. Les critères de tolérance sur la valeur et la localisation de la dose sont fixés de manière à avoir le meilleur compromis en termes de distribution spatiale et de temps de calcul. Nous proposons ici des paramètres permettant d'atteindre ces critères de précision. Dans la deuxième partie du travail, nous étudions la réponse des films radiochromiques MDv2-55 pour le contrôle qualité des faisceaux d'ions carbone et protons. Nous avons en particulier observé et étudié l'effet de saturation de ces films dosimétriques pour les irradiations à TEL élevés (≥ 20 KeV/µm) dans des milieux homogènes et hétérogènes. Cet effet est dû à la forte densité d'ionisation autour de la trace de particule. Nous avons proposé et développé un modèle appelé « RADIS RAdiochromic films Dosimetry for Ions using Simulations » qui permet de prédire la réponse de ces films avec la prise en compte de cet effet de saturation. Ce modèle est basé sur la réponse des films en photons et la saturation des films à des dépôts d'énergies linéïques élevés calculée par Monte Carlo. Plusieurs types de faisceaux ont été étudiés : ions carbone, protons et photons à différentes énergies. Ces expérimentations ont été menées au Grand Accélérateur National d'Ions Lourds (GANIL), au Centre de protonthérapie d'Orsay (CPO), au Centre A. Lacassagne (CAL) et au Centre Léon Bérard (CLB). A l'aide du modèle, nous pouvons ainsi reproduire la densité optique des films le long du profil de Bragg pour tous les faisceaux avec une précision meilleure que 2%. / Because of the increase in dose at the end of the range of ions, dose delivery during patient treatment with hadrontherapy should be controlled with high precision. Monte Carlo codes are now considered mandatory for validation of clinical treatment planing and as a new tool for dosimetry of ion beams. In this work, we aimed to calculate the absorbed dose using Monte Carlo simulation Geant4/Gate. The ejffect on the dose calculation accuracy of dierent Geant4 parameters has been studied for mono-energetic carbon ion beams of 300 MeV/u in water. The parameters are : the production threshold of secandary particules and the maximum step limiter of the particle track. Tolerated criterion were choosen to meet the precision required in radiotherapy (2%, 2mm) and to obtain the best compromise on dose distribution and computational time.We propose here the values of parameters in order to satisfy the precision required. In the second part of this work, we will study the response of radiochromic lms MD-v2-55 for quality control in proton and carbon ion beams. We have particularly observed and studie the quenching effect of dosimetric lms for high LET (20 KeV/m) irradiations in homogeneous and heterogeneous medium. This eject is due to the high ionization density around the track of the particule. We have developped a method to predict the response of radiochromic lms taking into account the saturation effect. This model is called the RADIS model forRAdiochromic films. Dosimetry for Ions using Simulations". It is based on the response of lms under photon irradiations and the saturation of lms due to high linear energy deposit calculated by Monte Carlo. Four beams were used in this study and aimed to validate the model for hadrontherapy applications : carbon ions, protons and photons at different energies. Experiments were performed at Grand Accélérateur National d'Ions Lourds (GANIL), Proton therpay center of Orsay (CPO), A. Lacassagne proton center (CAL) and Leon Berard cancer center (CLB). The model showed very good agreement between the measured and calculated optical density with an error less than 2%.
36

Search for dark matter with EDELWEISS-III excluding background from muon-induced neutrons / Recherche de matière noire avec l'expérience EDELWEISS-III excluant le bruit de fond neutron induit par les muons

Kéfélian, Cécile 05 February 2016 (has links)
Le but de l'expérience EDELWEISS est la détection directe de matière noire sousforme de WIMPs, par l'étude de leur diffusion élastique sur les noyaux de germanium des détecteurs bolomètriques. Le plus problématique des bruits de fond provient des neutrons pouvant mimer l'interaction d'un WIMP dans un détecteur. Ces neutrons sont notamment produits par les rares muons cosmiques de haute énergie qui atteignent le laboratoire souterrain malgré les 4800 m w.e. de roche. Les muons résiduels sont détectés par un système veto de 46 modules de scintillateur plastique entourant l'expérience, qui permet de rejeter la plupart du bruit de fond associé. La détermination précise du bruit de fond neutron résiduel induit par ces muons dans EDELWEISS-III, essentielle pour l'identification des WIMPs, est le but de cette thèse. Le taux de bruit de fond dépend de la géométrie de l'expérience ainsi que des matériaux utilisés, qui ont subi d'importantes modifications depuis EDELWEISS-II. Des simulations GEANT4 du passage des muons dans la nouvelle géométrie ont été réalisées afin d'extraire le taux d'événements induits par les muons dans les bolomètres. Ce taux est en bon accord avec le taux mesuré extrait des données du Run308. En parallèle, une limite inférieure sur l'efficacité du veto muon a été extraite à partir des données bolomètres. Une nouvelle méthode basée sur l'utilisation d'une source d'AmBe a été développée afin d'extraire l'efficacité de chaque module de la simulation. À partir de ces résultats, il a été montré que le bruit de fond attendu est négligeable pour la recherche de WIMPs avec les données du Run308 et ne limitera pas la sensibilité future d'EDELWEISS-III / The aim of the EDELWEISS-III experiment is to detect the elastic scattering of WIMPs from the galactic dark matter halo on germanium bolometers. The most problematic background arises from neutrons, which can mimic a WIMP interaction in a detector. Neutrons are notably induced by high energy cosmic ray muons reaching the underground laboratory despite the 4800 m w.e. of rock overburdened. Remaining muons are tagged using an active muon-veto system of 46 plastic scintillator modules surrounding the experiment, which allows to reject most of the associated background. The goal of this thesis was to give a precise estimation of the irreducible muon-induced neutron background, needed to identify a potential WIMP signal. The expected background depends on the geometry of the experiment as well as on the used materials, both strongly modified since EDELWEISS-II. Geant4-based simulations of muons through the modified geometry were performed to derive the rate of events induced by muons in the bolometer array. This rate has been shown to be in good agreement with the measured one extracted from the Run308 data. In parallel, a lower limit on the muon-veto efficiency was derived using bolometer data only. A new method based on an AmBe source was developed to extract precisely the detection efficiency of individual modules from the simulation. From these results, it was shown that the expected background is negligible for the WIMP search analyses performed with the Run308 data and won't limit the future sensitivity of the EDELWEISS-III experiment
37

Caractérisation et modélisation d'objets archéologiques en vue de leur datation par des méthodes paléo-dosimétriques : simulation des paramètres dosimétriques sous Geant4 / Characterization and modeling of archaeological objects for their dating by Paleo-dosimetric methods : simulation of the dosimetric parameters with Geant4

Martin, Loïc 07 December 2015 (has links)
Les méthodes paléodosimétriques permettent d’obtenir l’âge de certains matériaux de nature minérale qui se comportent comme des dosimètres naturels, l’âge étant alors donné par le rapport de la dose accumulée depuis l’événement à dater, au débit de dose naturel auquel l'échantillon a été soumis. La détermination du débit de dose repose le plus souvent sur des modèles simples, qui seuls permettent des calculs explicites, mais ces modèles ne reproduisent que très imparfaitement la diversité des situations rencontrées. La modélisation informatique permet d’envisager des modèles plus complexes et plus réalistes, qui conduisent à simuler numériquement le débit de dose. Dans ce travail, la boite à outils Geant4, qui permet de simuler les interactions particule-matière selon la méthode de Monte-Carlo, a été utilisée pour créer des modèles complexes, ainsi que des outils de modélisation accessibles et adaptables aux différents types d'échantillons et situations dosimétriques. Des simulations ont tout d'abord été faites à partir de modèles basiques afin d'étudier l’origine des variations du débit de dose dans des sédiments, mettant en évidence les limites des modèles simples utilisés couramment. Ces informations ont permis d'orienter le développement d'outils de modélisation basés sur les codes de Geant4, et aussi de préciser les protocoles d'analyse des échantillons permettant de réunir les données nécessaires aux simulations numériques. Le programme DosiVox permet de modéliser simplement une grande variété d'échantillons grâce à une représentation voxélisée de l’objet et de son environnement, et de simuler la radioactivité pour calculer la distribution spatiale du débit de dose. Il a été développé dans une optique d'accessibilité et d'usage courant. Des comparaisons avec des situations dosimétriques préalablement étudiées, ou mesurées, ont montré la pertinence des modélisations, et les possibilités de cet outil informatique sont exposées au travers d’une série d'exemples et d'applications. La caractérisation de la distribution des débits de dose bêta dans les sédiments hétérogènes constitue l'une des problématiques les plus complexes à traiter. En plus d'une étude destinée à évaluer le potentiel de DosiVox à considérer ces situations, le programme DosiSed a été développé pour modéliser spécifiquement des ensembles polyminéraux de grains. Cet outil a permis d'étudier l'hétérogénéité du débit de dose dans des échantillons réels, ainsi que d'inclure certains résultats dans une problématique de datation. / The paleodosimetric dating methods allow to obtain the age of some mineral materials which behave as natural dosimeters, the age being derived as the ratio of the dose accumulated from the dated event and the natural dose rate to which the sample was subjected.. The determination of the dose rate is usually based on simple models which only allow explicit calculations, but these models reproduce very imperfectly the diversity of situations encountered. Computer modeling allows to represent more complex and more realistic models, which lead to numerically simulate the dose rate. In this work, the toolbox Geant4, allowing to simulate particle-matter interactions by the Monte-Carlo method, was used to create complex models , as well as modeling tools accessible and adaptable to different types of samples and dosimetric situations. Simulations were first made with basic models in order to study the origin of dose rate variations in sediments, highlighting the limits of the simple models commonly used. This information was used to guide the development of modeling tools based on the Geant4 codes, and also to specify the protocols of samples analysis for gathering the data needed for numerical simulations. The DosiVox software allows to easily model a wide variety of samples through a voxelised representation of the object and its environment, and to simulate the radioactivity for calculating the spatial distribution of the dose rate. It was developed with a view of accessibility and current use. Comparisons with dosimetric situations previously studied or measured showed the relevance of the modelings, and the possibilities of this computer tool are exposed through a series of examples and applications. The characterization of the beta dose rate distribution in heterogeneous sediment is one of the most complex problems to be treated. In addition to a study aims at assessing the potential of DosiVox to consider these situations, the DosiSed software was developed specifically for modeling poly-mineral sets of grains. This tool was used to study the heterogeneity of the dose rate in real samples and allowed to include some of the results in a dating problematic.
38

Versatile low-energy electron source at the PHIL accelerator to characterise Micromegas with integrated Timepix CMOS readout and study dE/dx for low energy electrons / Source polyvalente d'électrons de basse énergie sur l'accélérateur PHIL pour caractériser des détecteurs Micromegas avec une lecture CMOS intégrée et étudier dE/dx pour les électrons de basse énergie

Krylov, Vladyslav 12 June 2018 (has links)
Dans le cadre de cette thèse, la conception, la construction et la mise en service de la plateforme de test LEETECH ont été réalisées. La performance de LEETECH, y compris le mode de fonctionnement à faible multiplicité a été démontrée. En fournissant des paquets d’électrons avec une énergie ajustable jusqu’à 3.5 MeV, une multiplicité ajustable à partir d’électrons simples et une durée des paquets jusqu’à 20ps, LEETECH prend sa place entre les faisceaux tests de hautes énergies et de coûts élevés d’un part et l’utilisation de sources radioactifs d’autre part. Dans la région, qui correspond à la particule d’ionisation minimale, la plateforme offre aux détecteurs de traces les conditions similaires aux celles de faisceaux des hautes énergies. Le mode de fonctionnement à faible multiplicité a été étudié en utilisant un détecteur diamant de grande surface. En plus une capacité d’un capteur diamant de résoudre des paquets à faible nombre des particules a été démontrée. Dans le cadre du développement de la chambre à projection temporelle (TPC) pour le projet ILC, une session de test a été dédiée à un détecteur Micromegas/InGrid de large surface. Pour la première fois les pertes d’énergie par un électron dans un mélange de gaz basée sur Helium ont été mesurées pour une énergie de quelques MeV. La résolution en dE/dx et un algorithme pour la reconstruction de traces ont été développés. Une caractérisation préliminaire du quartz barre lu par MCPPMT – un candidat pour le détecteur temps-de- vol (TOF) avec la mission de l’identification des hadrons chargés dans le futur usine tau-charm HIEPA – a été accomplie. La résolution temporelle de 50 ps obtenue pour le détecteur étudié met cette technologie prometteuse pour les études plus approfondies. / Within the present thesis the design, construction and commissioning of a new test beam facility LEETECH have been performed. Performance of the new facility, including low-multiplicity operation mode has been demonstrated. A number of interesting detector tests, including large-area diamond, Micromegas/InGrid and quartz bar detectors have been performed. Development of new detector technologies for future high-energy physics collider experiments calls for selection of versatile test beam facilities, permitting to choose or adjust beam parameters such as particles type, energy and beam intensity, are irreplaceable in characterization and tests of developed instruments. Major applications comprise generic detector R&D, conceptual design and choice of detector technologies, technical design, prototypes and full-scale detector construction and tests, detector calibration and commissioning. A new test beam facility LEETECH (Low Energy Electron TECHnique) was designed, constructed and commissioned in LAL (Orsay) as an extension of existing PHIL accelerator. Providing electron bunches of adjustable energy (up to 3.5 MeV), intensity (starting from a few particles per bunch) and bunch time duration (down to 20 ps), LEETECH fills the gap between high-cost high-energy test beam facilities and use of radioactive sources. Covering a minimum-ionization particles region (electrons of energy above 1.6 MeV), LEETECH provides for tracking detectors similar conditions as high-energy facilities. Using LEETECH as an electron source, several types of detectors were investigated in order to study their performance or applications, also providing a characterization of the LEETECH performance. First studies of the LEETECH facility were performed with a plastic scintillator coupled to the Micro-channel plate photomultiplier. A low-multiplicity mode was investigated using the diamond sensor, at the same time demonstrating its ability to resolve bunches consisting of a few particles. In framework of Time Projection Chamber development for the ILC project, a session dedicated to a large-area Micromegas/InGrid module was performed. For the first time the electron energy losses in Helium-based gas mixtures were measured for the energies of few MeV. The dE/dx resolution was obtained and track reconstruction algorithm was developed. Being a candidate for the time-of- flight detector of the BESIII upgrade and future HIEPA tau-charm factories, a preliminary characterization of the quartz bar performed. The time resolution of the detector module of 50 ps was obtained, giving a promising results for the further detector studies.
39

Etude de faisabilité d'un détecteur dédié à la discrimination bêta/gamma / Study of the feasibility of a detector dedicated to the beta/gamma discrimination

Luo, Yiyan 04 December 2018 (has links)
A des fins de propreté radiologique, les exploitants nucléaires doivent évaluer l'activité surfacique résiduelle, telle que la contamination bêta. Pour cela, les contaminamètres sont essentiels. Dans ce cadre, EDF R&D a proposé un projet de recherche visant à étudier la faisabilité d’un contaminamètre innovant permettant de détecter l’activité surfacique bêta in situ, alors qu’elle est actuellement mesurée ex-situ.L'objectif principal de ce travail est de détecter une contamination bêta surfacique de 0,4 Bq/cm^2 dans un environnement gamma élevé, jusqu'à 100 µSv/h. Cela exige un détecteur ayant une performance de discrimination bêta/gamma élevée. Plusieurs technologies basées sur un scintillateur et/ou un détecteur à gaz ont été étudiées. Des simulations Geant4 ont été effectuées pour optimiser la configuration des technologies retenues (géométrie, matériaux, etc.). Suite à ces simulations, deux prototypes, de type Phoswich, optimisés ont été fabriqués et testés à l’aide de sources bêta et gamma au laboratoire ( LPC Caen). En outre, deux campagnes d’essai ont été menées dans une centrale nucléaire (CNPE de Chinon) afin d'évaluer les performances des prototypes développés dans un bruit de fond gamma réaliste. Les simulations Geant4 et les tests sont discutés dans cette thèse. / For radiological cleanliness purpose, nuclear operators have to assess surface residual activity such as beta contamination. To this aim, contamination monitors are essential. In this context, EDF R&D proposed a research project in order to study the feasibility of an innovative contamination monitor to detect beta surface activity in situ which is until now performed ex situ. The main objective is to detect a 0.4 Bq/cm^2 beta surface contamination in a high gamma background up to 100 μSv/h. This demands the detector to have a high beta/gamma discrimination performance. Several technologies based on scintillator and/or gas filled detector have been investigated. Geant4 simulations have been carried out to optimise the configuration of the chosen detector such as geometry, materials, etc. Two simulation-optimised prototypes based on Phoswich detectors have been developed and tested with beta and gamma sources in a laboratory framework (LPC Caen). Furthermore, two experimental campaigns have been conducted in a nuclear power plant (NPP of Chinon) in order to evaluate the performance of the developed prototypes in a realistic gamma background environment. The Geant4 simulations and the experimental work are discussed in this thesis.
40

Monte Carlo microdosimetry of charged-particle microbeam irradiations / Micro-dosimétrie d'irradiations par microfaisceau d'ions par méthodes Monte-Carlo

Torfeh, Eva 01 October 2019 (has links)
L’interaction des particules chargées avec la matière conduit à un dépôt d’énergie très localisé dans des traces de dimensions sub-micrométriques. Cette propriété unique rend ce type de rayonnement ionisant particulièrement intéressant pour disséquer les mécanismes moléculaires radio-induits suite à l’échelle de la cellule. L’utilisation de microfaisceaux de particules chargées offre en outre la capacité d’irradier sélectivement à l’échelle du micromètre avec une dose contrôlée jusqu’à la particule unique. Mon travail a porté sur des irradiations réalisées avec le microfaisceau de particules chargées de la plateforme AIFIRA (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine) du CENBG. Ce microfaisceau délivre des protons et particules alpha et est dédié aux irradiations ciblées in vitro (cellules humains) et in vivo (C. elegans).En complément de l’intérêt qu’elles présentent pour des études expérimentales, les dépôts d’énergie et les interactions des particules chargées avec la matière peuvent être modélisés précisément tout au long de leur trajectoire en utilisant des codes de structures de traces basés sur des méthodes Monte Carlo. Ces outils de simulation permettent une caractérisation précise de la micro-dosimétrie des irradiations allant de la description détaillée des interactions physiques à l’échelle nanométrique jusqu’à la prédiction du nombre de dommages à l’ADN et leurs distributions dans l’espace.Au cours de ma thèse, j’ai développée des modèles micro-dosimétriques basés sur l’outil de modélisation Geant4-DNA dans deux cas. Le premier concerne la simulation de la distribution d’énergie déposée dans un noyau cellulaire et le calcul du nombre des différents types de dommages ADN (simple et double brin) aux échelles nanométrique et micrométrique, pour différents types et nombres de particules délivrées. Ces résultats sont confrontés à la mesure expérimentale de la cinétique de protéines de réparation de l’ADN marquées par GFP (Green Fluorescent Protein) dans des cellules humaines. Le second concerne la dosimétrie de l’irradiation d’un organisme multicellulaire dans le cadre d’études de l’instabilité génétique dans un organisme vivant au cours du développement (C. elegans). J’ai simulé la distribution de l’énergie déposée dans différents compartiments d’un modèle réaliste en 3D d’un embryon de C. elegans suite à des irradiations par protons. Enfin, et en parallèle de ces deux études, j’ai développé un protocole pour caractériser le microfaisceau d'AIFIRA à l’aide de détecteurs de traces fluorescent (FNTD) pour des irradiations par protons et par particules alpha. Ce type de détecteur permet en effet de visualiser les trajectoires des particules incidentes avec une résolution de l’ordre de 200 nm et d’examiner la qualité des irradiations cellulaires réalisées par le microfaisceau. / The interaction of charged particles with matter leads to a very localized energy deposits in sub-micrometric tracks. This unique property makes this type of ionizing radiation particularly interesting for deciphering the radiation-induced molecular mechanisms at the cell scale. Charged particle microbeams (CPMs) provide the ability to target a given cell compartment at the micrometer scale with a controlled dose down to single particle. My work focused on irradiations carried out with the CPM at the AIFIRA facility in the CENBG (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). This microbeam delivers protons and alpha particles and is dedicated to targeted irradiation in vitro (human cells) and in vivo (C. elegans).In addition to their interest for experimental studies, the energy deposits and the interactions of charged particles with matter can be modeled precisely along their trajectory using track structure codes based on Monte Carlo methods. These simulation tools allow a precise characterization of the micro-dosimetry of the irradations from the detailed description of the physical interactions at the nanoscale to the prediction of the number of DNA damage, their complexity and their distribution in space.During my thesis, I developed micro-dosimetric models based on the Geant4-DNA modeling toolkit in two cases. The first concerns the simulation of the energy distribution deposited in a cell nucleus and the calculation of the number of different types of DNA damage (single and double strand breaks) at the nanometric and micrometric scales, for different types and numbers of delivered particles. These simulations are compared with experimental measurements of the kinetics of GFP-labeled (Green Fluorescent Protein) DNA repair proteins in human cells. The second is the dosimetry of irradiation of a multicellular organism to study the genetic instability in a living organism during development (C. elegans). I simulated the distribution of the energy deposited in different compartments of a realistic 3D model of a C. elegans embryo following proton irradiations. Finally, and in parallel with these two studies, I developed a protocol to characterize the AIFIRA microbeam using fluorescent nuclear track detector (FNTD) for proton and alpha particle irradiations. This type of detector makes it possible to visualize in 3D the incident particle tracks with a resolution of about 200 nm and to examine the quality of the cellular irradiations carried out by the CPM.

Page generated in 0.4356 seconds