• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 43
  • 41
  • 10
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 120
  • 52
  • 52
  • 46
  • 37
  • 26
  • 26
  • 22
  • 16
  • 16
  • 16
  • 13
  • 13
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Détection des événements de "Minimum Bias" et neutrons avec les détecteurs ATLAS-MPX par simulations

Macana Goia, Jorge Andres 08 1900 (has links)
Un réseau de seize détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Les détecteurs ATLAS-MPX sont sensibles au champ mixte de radiation de photons et d’électrons dans la caverne d’ATLAS et sont recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons thermiques et des neutrons rapides respectivement. Les collisions à haute énergie sont dominées par des interactions partoniques avec petit moment transverse pT , associés à des événements de “minimum bias”. Dans notre cas la collision proton-proton se produit avec une énergie de 7 TeV dans le centre de masse avec une luminosité de 10³⁴cm⁻²s⁻¹ telle que fixée dans les simulations. On utilise la simulation des événements de "minimum bias" générés par PYTHIA en utilisant le cadre Athena qui fait une simulation GEANT4 complète du détecteur ATLAS pour mesurer le nombre de photons, d’électrons, des muons qui peuvent atteindre les détecteurs ATLASMPX dont les positions de chaque détecteur sont incluses dans les algorithmes d’Athena. Nous mesurons les flux de neutrons thermiques et rapides, générés par GCALOR, dans les régions de fluorure de lithium et de polyéthylène respectivement. Les résultats des événements de “minimum bias” et les flux de neutrons thermiques et rapides obtenus des simulations sont comparés aux mesures réelles des détecteurs ATLAS-MPX. / A network of sixteen ATLAS-MPX detectors has been put in operation in the ATLAS detector at CERN-LHC. ATLAS-MPX detectors are sensitive to a mixed radiation field of photons and electrons in the ATLAS cavern and are covered with lithium fluoride and polyethylene converters in order to increase the detection sensitivity of thermal neutrons and fast neutrons respectively. High energy collisions are dominated by partonic interactions with small transverse moment pT , associated with "minimum bias" events. In our case, the proton-proton collision occurs with an center-of-mass energy of 7 TeV with a fixed luminosity of 10³⁴cm⁻²s⁻¹ in the simulations. We use "minimum bias" events simulation generated by PYTHIA using the framework Athena. Athena’s framework makes a full GEANT4 simulation of the ATLAS detector. We include the positions of each detector in the Athena algorithms for measuring the number of photons, electrons and muons that can reach the detectors ATLAS-MPX. We measure the fluxes of thermal and fast neutrons generated by GCALOR in lithium fluoride and polyethylene regions respectively. The "minimum bias" events results and the flow of thermal and fast neutrons obtained by simulations are compared with real measurements of the ATLAS-MPX detectors.
72

Implémentation de la répartition de charge et du mode TOT pour la simulation d’un détecteur Timepix à pixels

Dallaire, Frédérick 03 1900 (has links)
Les détecteurs à pixels Medipix ont été développés par la collaboration Medipix et permettent de faire de l'imagerie en temps réel. Leur surface active de près de $2\cm^2$ est divisée en 65536~pixels de $55\times 55\um^2$ chacun. Seize de ces détecteurs, les Medipix2, sont installés dans l'expérience ATLAS au CERN afin de mesurer en temps réel les champs de radiation produits par les collisions de hadrons au LHC. Ils seront prochainement remplacés par des Timepix, la plus récente version de ces détecteurs, qui permettent de mesurer directement l'énergie déposée dans chaque pixel en mode \textit{time-over-threshold} (TOT) lors du passage d'une particule dans le semi-conducteur. En vue d'améliorer l'analyse des données recueillies avec ces détecteurs Timepix dans ATLAS, un projet de simulation Geant4 a été amorcé par John Id\'rraga à l'Université de Montréal. Dans le cadre de l'expérience ATLAS, cette simulation pourra être utilisée conjointement avec Athena, le programme d'analyse d'ATLAS, et la simulation complète du détecteur ATLAS. Sous l'effet de leur propre répulsion, les porteurs de charge créés dans le semi-conducteur sont diffusés vers les pixels adjacents causant un dépôt d'énergie dans plusieurs pixels sous l'effet du partage de charges. Un modèle effectif de cette diffusion latérale a été développé pour reproduire ce phénomène sans résoudre d'équation différentielle de transport de charge. Ce modèle, ainsi que le mode TOT du Timepix, qui permet de mesurer l'énergie déposée dans le détecteur, ont été inclus dans la simulation afin de reproduire adéquatement les traces laissées par les particules dans le semi-conducteur. On a d'abord étalonné le détecteur pixel par pixel à l'aide d'une source de $\Am$ et de $\Ba$. Ensuite, on a validé la simulation à l'aide de mesures d'interactions de protons et de particules $\alpha$ produits au générateur Tandem van de Graaff du Laboratoire René-J.-A.-Lévesque de l'Université de Montréal. / The pixelated Medipix detectors have been developed by the Medipix Collaboration to perform real-time imaging. The semiconducting chip is divided into 65536 pixels of $55\times 55\um^2$ for a total active area of nearly $2\cm^2$. Because of their sensitivity to all kinds of particles, sixteen Medipix2 detectors (ATLAS-MPX) have been placed in the ATLAS detector and its cavern to measure for the radiation produced by the head-on proton collisions produced at the LHC. At the next ATLAS upgrade, the ATLAS-MPX network will be extended to include the Timepix detectors, the latest version that allows one to measure the total energy deposited in the semiconductor. To improve data analysis, a Geant4 simulation project of a Timepix detector was initiated by John Id\'arraga at the Université de Montréal. In the framework of the ATLAS experiment, this simulation could be used with Athena, the ATLAS analysis software, and the full ATLAS simulation. Due to their repulsivity, the charge carriers created by an incoming particle in the pixelated detector are spread over the surrounding pixels causing a charge sharing effect. An effective model has been developed to reproduce this effect without resolving the charge drift's differential equation. This model and the \textit{time-over-threshold} mode of the Timepix have been included in the simulation to reproduce the tracks left by the striking particles. First, one had to individually calibrate each pixel of the device with $\Am$ and $\Ba$ sources. The simulation's validation has been performed with low energy protons and $\alpha$ particles delivered by the van de Graaff Tandem at the Laboratoire René-J.-A.-Lévesque of the Université de Montréal.
73

Simulation studies for the in-vivo dose verification of particle therapy

Rohling, Heide 21 July 2015 (has links) (PDF)
An increasing number of cancer patients is treated with proton beams or other light ion beams which allow to deliver dose precisely to the tumor. However, the depth dose distribution of these particles, which enables this precision, is sensitive to deviations from the treatment plan, as e.g. anatomical changes. Thus, to assure the quality of the treatment, a non-invasive in-vivo dose verification is highly desired. This monitoring of particle therapy relies on the detection of secondary radiation which is produced by interactions between the beam particles and the nuclei of the patient’s tissue. Up to now, the only clinically applied method for in-vivo dosimetry is Positron Emission Tomography which makes use of the beta+-activity produced during the irradiation (PT-PET). Since from a PT-PET measurement the applied dose cannot be directly deduced, the simulated distribution of beta+-emitting nuclei is used as a basis for the analysis of the measured PT-PET data. Therefore, the reliable modeling of the production rates and the spatial distribution of the beta+-emitters is required. PT-PET applied during instead of after the treatment is referred to as in-beam PET. A challenge concerning in-beam PET is the design of the PET camera, because a standard full-ring scanner is not feasible. For instance, a double-head PET camera is applicable, but low count rates and the limited solid angle coverage can compromise the image quality. For this reason, a detector system which provides a time resolution allowing the incorporation of time-of-flight information (TOF) into the iterative reconstruction algorithm is desired to improve the quality of the reconstructed images. Secondly, Prompt Gamma Imaging (PGI), a technique based on the detection of prompt gamma-rays, is currently pursued. Concerning the emissions of prompt gamma-rays during particle irradiation, experimental data is not sufficiently available, making simulations necessary. Compton cameras are based on the detection of incoherently scattered photons and are investigated with respect to PGI. Monte Carlo simulations serve for the optimization of the camera design and the evaluation of criteria for the selection of measured events. Thus, for in-beam PET and PGI dedicated detection systems and, moreover, profound knowledge about the corresponding radiation fields are required. Using various simulation codes, this thesis contributes to the modelling of the beta+-emitters and photons produced during particle irradiation, as well as to the evaluation and optimization of hardware for both techniques. Concerning the modeling of the production of the relevant beta+-emitters, the abilities of the Monte Carlo simulation code PHITS and of the deterministic, one-dimensional code HIBRAC were assessed. The Monte Carlo tool GEANT4 was applied for an additional comparison. For irradiations with protons, helium, lithium, and carbon, the depth-dependent yields of the simulated beta+-emitters were compared to experimental data. In general, PHITS underestimated the yields of the considered beta+-emitters in contrast to GEANT4 which provided acceptable values. HIBRAC was substantially extended to enable the modeling of the depth-dependent yields of specific nuclides. For proton beams and carbon ion beams HIBRAC can compete with GEANT4 for this application. Since HIBRAC is fast, compact, and easy to modify, it could be a basis for the simulations of the beta+-emitters in clinical application. PHITS was also applied to the modeling of prompt gamma-rays during proton irradiation following an experimental setup. From this study, it can be concluded that PHITS could be an alternative to GEANT4 in this context. Another aim was the optimization of Compton camera prototypes. GEANT4 simulations were carried out with the focus on detection probabilities and the rate of valid events. Based on the results, the feasibility of a Compton camera setup consisting of a CZT detector and an LSO or BGO detector was confirmed. Several recommendations concerning the design and arrangement of the Compton camera prototype were derived. Furthermore, several promising event selection strategies were evaluated. The GEANT4 simulations were validated by comparing simulated to measured energy depositions in the detector layers. This comparison also led to the reconsideration of the efficiency of the prototype. A further study evaluated if electron-positron pairs resulting from pair productions could be detected with the existing prototype in addition to Compton events. Regarding the efficiency and the achievable angular resolution, the successful application of the considered prototype as pair production camera to the monitoring of particle therapy is questionable. Finally, the application of a PET camera consisting of Resistive Plate Chambers (RPCs) providing a good time resolution to in-beam PET was discussed. A scintillator-based PET camera based on a commercially available scanner was used as reference. This evaluation included simulations of the detector response, the image reconstructions using various procedures, and the analysis of image quality. Realistic activity distributions based on real treatment plans for carbon ion therapy were used. The low efficiency of the RPC-based PET camera led to images of poor quality. Neither visually nor with the semi-automatic tool YaPET a reliable detectability of range deviations was possible. The incorporation of TOF into the iterative reconstruction algorithm was especially advantageous for the considered RPC-based PET camera in terms of convergence and artifacts. The application of the real-time capable back projection method Direct TOF for the RPCbased PET camera resulted in an image quality comparable to the one achieved with the iterative algorihms. In total, this study does not indicate the further investigation of RPC-based PET cameras with similar efficiency for in-beam PET application. To sum up, simulation studies were performed aimed at the progress of in-vivo dosimetry. Regarding the modeling of the beta+-emitter production and prompt gamma-ray emissions, different simulation codes were evaluated. HIBRAC could be a basis for clinical PT-PET simulations, however, a detailed validation of the underlying cross section models is required. Several recommendations for the optimization of a Compton Camera prototype resulted from systematic variations of the setup. Nevertheless, the definite evaluation of the feasibility of a Compton camera for PGI can only be performed by further experiments. For PT-PET, the efficiency of the detector system is the crucial factor. Due to the obtained results for the considered RPC-based PET camera, the focus should be kept to scintillator-based PET cameras for this purpose.
74

Modelling and simulation of physics processes for in-beam imaging in hadrontherapy / Modélisation et simulation des processus physiques pour l’imagerie en ligne de l’hadronthérapie

Pinto, Marco 19 December 2014 (has links)
L'hadronthérapie joue un rôle de plus en plus important au sein des techniques de radiothérapie grâce aux propriétés balistiques des ions et, dans le cas de ceux plus lourds que les protons, à une augmentation de l'efficacité biologique dans la région tumorale. Ces caractéristiques permettent une meilleure conformation de la dose délivrée au volume tumoral et elles permettent en particulier de traiter des tumeurs radio-résistantes. Elles conduisent cependant à une grande sensibilité du parcours des ions aux incertitudes du traitement. C'est dans ce contexte qu'a été proposée la détection de radiations secondaires émises lors des interactions nucléaires induites par les ions incidents dans le patient. La tomographie par émission de positons et la détection des rayons gamma prompts ont notamment fait l'objet d'une recherche intense ces dernières années. Le réseau de formation européen ENTERVISION, soutenu par la communauté ENLIGHT, a été crée fin 2009 pour développer ce type d'imagerie et, plus généralement, traiter les incertitudes de traitement en hadronthérapie. Le travail présenté dans ce manuscrit et intitulé ≪ Modélisation et simulation des processus physiques pour l'imagerie en ligne de l'hadronthérapie ≫ est l'un des nombreux travaux issus de ce projet. Bien que le sujet soit particulièrement large, le fil conducteur de ce travail a été une étude systématique visant in fine une implémentation d'un dispositif d'imagerie ≪ gamma prompts ≫ utilisable à la fois en faisceau de protons et d'ions carbone / Hadrontherapy is taking an increasingly important role in radiotherapy thanks to the ballistic properties of ions and, for those heavier than protons, an enhancement in the relative biological effectiveness in the tumour region. These features allow for a higher tumour conformality possible and gives the opportunity to tackle the problem of radioresistant tumours. However, they may lead to a great sensitivity of ion range to treatment uncertainties, namely to morphological changes along their path. In view of this, the detection of secondary radiations emitted after nuclear interactions between the incoming ions and the patient have been long proposed as ion range probes and, in this regard, positron emitters and prompt gammas have been the matter of intensive research. The European training network ENTERVISION, supported by the ENLIGHT community, was created in the end of 2009 in order to develop such imaging techniques and more generally to address treatment uncertainties during hadrontherapy. The present work is one of the many resulting from this project, under the subject “Modelling and simulation of physics processes for in-beam imaging in hadrontherapy”. Despite the extensive range of the topic, the purpose was always to make a systematic study towards the clinical implementation of a prompt-gamma imaging device to be used for both proton and carbon ion treatments
75

Charged particle diagnostics for PETAL, calibration of the detectors and development of the demonstrator / Diagnostics de particules chargées pour PETAL, étalonnage des détecteurs and développement d’un démonstrateur

Rabhi, Nesrine 06 December 2016 (has links)
Afin de protéger leurs systèmes de détection de l'impulsion électromagnétique géante générée par l'interaction du laser PETAL avec sa cible, les diagnostics de PETAL seront équipés de détecteurs passifs. Pour les ensembles SEPAGE et SESAME, une combinaison d'Imaging Plates (IP) et de couches de protection de matériaux de grand numéro atomique sera utilisée, qui permettra: 1) d'assurer que la réponse des détecteurs sera indépendante de son environnement mécanique proche dans les diagnostics et donc homogène sur toute la détection, 2) de blinder les détecteurs contre les photons de haute énergie produits dans la cible de PETAL. Dans le travail présenté ici, nous avons réalisé des expériences d'étalonnage avec les IPs auprès d'installations générant des électrons, des protons ou des ions, dans le but de couvrir le domaine en énergie cinétique de la détection des particules chargées de PETAL, de 0.1 à 200 MeV. L'introduction a pour but de décrire les méthodes et outils utilisés au cours de cette étude. Le second chapitre présente les résultats de deux expériences réalisées avec des électrons dans le domaine d'énergie cinétique [5-180] MeV. Le troisième chapitre décrit une expérience et ses résultats avec les protons entre 80 et 200 MeV étaient envoyés sur nos détecteurs. Le quatrième chapitre est consacré à une expérience utilisant des protons et des ions entre1 et 22 MeV en énergie de protons et dont l'objectif était l'étude de détecteurs et le test du démonstrateur de SEPAGE. Nous avons utilisé GEANT4 pour l'analyse de nos données et prédire la réponse de nos détecteurs dans le domaine 0.1 à 1000 MeV. / In order to protect their detection against the giant electromagnetic pulse generated by the interaction of the PETAL laser with its target, PETAL diagnostics will be equipped with passive detectors. For SESAME and SEPAGE systems, a combination of imaging plate (IP) detectors with high-Z material protection layers will be used to provide additional features such as: 1) Ensuring a response of the detector to be independent of its environment and hence homogeneous over the surface of the diagnostics; 2) Shielding the detectors against high-energy photons from the PETAL target. In this work, calibration experiments of such detectors based on IPs were performed at electron and proton facilities with the goal of covering the energy range of the particle detection at PETAL from 0.1 to 200 MeV. The introduction aims at providing the reader the methods and tools used for this study. The second chapter presents the results of two experiments performed with electrons in the range from 5 to 180 MeV. The third chapter describes an experiment and its results, where protons in the energy range between 80 and 200 MeV were sent onto detectors. The fourth chapter is dedicated to an experiment with protons and ions in the energy range from 1 to 22 MeV proton energy, which aimed at studying our detector responses and testing the demonstrator of the SEPAGE diagnostic. We used the GEANT4 toolkit to analyse our data and compute the detection responses on the whole energy range from 0.1 to 1000 MeV.
76

Photon elastic scattering background events in the SuperCDMS SNOLAB experiment

Hassan, Noah 10 1900 (has links)
Alors que la nouvelle génération de détecteurs directs de matière sombre est en cours de construction, dans l’espoir de trouver de la matière sombre avec une masse inférieure au GeV, il est important de comprendre comment le rayonnement naturel peut produire un fond d’interactions à faible énergie. Cette thèse s’intéressera à la simulation de la diffusion élastique des rayons γ, une source possible de fonds pour les détecteurs de matière sombre sub-GeV. La simulation utilise le logiciel SuperSim basé sur Geant4 afin de modéliser l’expérience SuperCDMS SNOLAB. Une version modifiée du G4JAEAElasticScatteringModel appelée CDMSJAEAElasticScatteringModel a été mise en oeuvre dans SuperSim afin de simuler les mécanismes de diffusion de photon élastiques Rayleigh, nucléaire Thomson et Delbrück. Le CDMSJAEAElasticScatteringModel ajoute la possibilité pour les particules γ de déposer de l’énergie après avoir été diffusées élastiquement. La validité de ces deux modèles a été vérifiée et des erreurs dans le logicielle ont été rencontrées dans leur traitement des distributions d’angle de diffusion des photons qui déterminent les spectres d’énergie déposée. Les sections efficaces totales sont en accord avec la documentation et d’autres sources. Malgré les erreurs logicielles, la simulation définit une limite inférieure sur le taux de diffusion élastique des rayons γ de ∼ 0,01 et ∼ 0,035 photon diffusé élastiquement par kg par an pour les détecteurs SuperCDMS SNOLAB au germanium et au silicium, respectivement. Ces limites inférieures sont définies à l’aide d’une coupure d’énergie de recul de 1 eV. Cela fait de la diffusion élastique des rayons γ une source importante de bruit de fond pour détecteurs SuperCDMS proposés avec des capacités de discrimination ER/NR à des énergies de recul à l’échelle eV. / While the new generation of direct dark matter detectors are being built in the hopes of finding sub-GeV dark matter, it is important to understand how natural radiation can produce a background of low-energy interactions. This thesis will analyze simulating γ-ray elastic scattering, a possible source of background for sub-GeV dark matter detectors. The simulation uses Geant4-based SuperSim software in order to model the SuperCDMS SNOLAB experiment. A modified version of the G4JAEAElasticScatteringModel called CDMSJAEAElasticScatteringModel was implemented into SuperSim in order to simulate the Rayleigh, nuclear Thomson and Delbrück γ-ray elastic scattering mechanisms. The CDMSJAEAElasticScatteringModel adds the ability for the γ particles to deposit energy after being elastically scattered. The validity of both these models was checked, and errors were encountered in their treatment of photon scattering angle distributions which determine the deposited energy spectra. The total cross sections are consistent with the documentation and other sources. Despite the bug, the simulation does set a lower bound on the γ-ray elastic scattering rate of ∼ 0.01 and ∼ 0.035 elastically scattered photon per kg per year for germanium and silicon SuperCDMS SNOLAB detectors, respectively. These lower bounds are set using a 1 eV recoil energy cutoff. In conclusion, γ-ray elastic scattering a significant source of background for proposed SuperCDMS detectors with ER/NR discrimination capabilities at eV-scale recoil energies.
77

Microdosimetric studies of Auger electrons from DNA-incorporated 123-I using the micronucleus assay and the Geant4 Monte Carlo simulation tookit

Fourie, Hein 12 1900 (has links)
Thesis (MSc)--Stellenbosch University, 2014. / ENGLISH ABSTRACT: This study’s focus is on the determination and quantization of radiation damage on a cellular level due to the decay of the Auger electron-emitting 123I and the replication of this energy deposition using Geant4 Monte Carlo simulations. The relatively short half-life of 123I (13.2 hours) makes it ideal for studies of Auger electrons which induce biological damage similar to that of high linear energy transfer radiations, when permitted to deposit their energy in close proximity to DNA. Due to small cellular dimensions, direct dose measurements are impossible but estimates may be made from Monte Carlo simulations. In this investigation the thymidine analogue 5-[123I]-iodo-2-deoxyuridine (123IUdR) was used to incorporate the 123I into the cellular DNA of T-lymphocytes from two human donors. Radiation induced micronuclei were numerated in binucleated cells using fluorescence microscopy. The energy deposition per decay of 123I was calculated within a spherical geometry, having the same size and density as a human lymphocyte, using the open source Geant4 toolkit. The absorbed energy per disintegration was used to convert the incorporated 123I activity (Bq) into absorbed dose (Gy) values, in order to compare the biological damage caused by the radioactive iodine to 60Co γ-radiation. A linear relationship between micronuclei frequency and 123I activity could be established. The linear dose-response noted for Auger electrons in the study is indicative of the high-LET nature of these particles. Using the linear-quadratic dose-response curve for micronuclei frequencies following exposure to graded doses of 60Co γ-rays, the relative biological effectiveness (RBE) of the DNA incorporated 123I estimated in this work was found to range from 19 ± 10 to 32 ± 7 for lymphocyte donor 1 and 15 ± 6 to 42 ± 11 for donor 2. The dose limiting RBE (RBEM) for lymphocyte donor 1 and 2 are respectively 34 ± 8 and 50 ± 15 and follows the expected shift in terms of the inherent radiosensitivity of the donors. We also considered the inclusion of the S-phase fraction of the lymphocytes in the dosimetry calculations. The resultant RBEs of the dose points of lymphocyte donor 1 ranges from 4 ± 2 to 7 ± 2, and those of donor 2 ranges from 3 ± 1 to 9 ± 2. The RBEM for lymphocyte donor 1 and 2 are respectively 7 ± 2 and 11 ± 3. The inclusion of the S-phase fraction reduces the calculated RBEs significantly and these observed RBE values relate well to those obtained in studies with fibroblasts and 125IUdR. / AFRIKAANSE OPSOMMING: Hierdie studie fokus op die bepaling en kwantisering van stralingskade op 'n sellulêre vlak as gevolg van die verval van 123I wat Auger elektrone afgee, asook die simulering van hierdie energie afsetting met behulp van die Geant4 Monte Carlo program. Die relatiewe kort half-leeftyd van 123I (13.2 uur) maak dit ideaal vir studies van Auger elektrone wat biologiese skade soortgelyk aan dié van 'n hoë lineêre-energie-oordrag uitstraling veroorsaak, indien die energie van die elektrone naby sellulêre DNA geabsorbeer word. As gevolg van die klein sellulêre dimensies is direkte dosis metings egter onmoontlik, maar skattings kan gemaak word met behulp van Monte Carlo simulasies. Die timidien analoog 5-[123I]-jodo-2-deoxyuridien (123IUdR) was in hierdie ondersoek gebruik om die 123I in die DNA van menslike T-limfosiete in te bou. Mikrokerne in dubbel-kernige selle wat vorm as gevolg van die Auger elektrone was getel met behulp van fluoressensie mikroskopie. Die energie afsetting per 123I verval was bereken binne ‘n sferiese geometrie, met dieselfde grootte en digtheid as 'n menslike limfosiet, met behulp van die Geant4 sagteware. Die geabsorbeerde energie per verval was gebruik om die geïnkorporeerde 123I aktiwiteit (Bq) om te skakel na ‘n waarde van geabsorbeerde dosis (Gy), ten einde die biologiese skade wat veroorsaak word deur die radioaktiewe jodium-123 met kobalt-60 gamma straling te vergelyk. ‘n Lineêre verwantskap tussen die mikrokerne frekwensies en die 123I aktiwiteit is vasgestel. Hierdie verwantskap vir Auger elektrone is 'n aanduiding van die hoë lineêre-energie-oordrag van hierdie deeltjies. Die lineêr-kwadratiese dosis-effek krommes vir mikrokerne frekwensies na blootstelling aan 60Co γ-strale was gebruik om die relatiewe biologiese doeltreffendheid (RBE) van die DNA geïnkorporeerde 123I te beraam. RBE waardes wissel van 19 ± 10 tot 32 ± 7 vir limfosiete van skenker 1 en 15 ± 6 tot 42 ± 11 vir skenker 2. Die dosis beperkte RBE (RBEM) vir limfosiet skenker 1 en 2 is onderskeidelik 34 ± 8 en 50 ± 15 en volg die verwagte skuif in terme van die inherente radiogevoeligheid van die skenkers. Die fraksie van limfosiete wat in S-fase was tydens die blootstelling aan 125IUdR was ingesluit in verdere dosimetrie berekeninge. Die gevolglike RBEs van die dosispunte van limfosiete van skenker 1 wissel van 4 ± 2 tot 7 ± 2 en dié van skenker 2 wissel van 3 ± 1 tot 9 ± 2. Die RBEM vir limfosiet skenker 1 en 2 is onderskeidelik 7 ± 2 en 11 ± 3. Die insluiting van die S-fase fraksie verminder die berekende RBEs aansienlik en die RBE waardes waargeneem hou goed verband met die wat in studies met fibroblaste en 125IUdR verkry is.
78

Études Monte Carlo des mesures d'étalonnage aux neutrons et aux particules alpha du détecteur PICASSO

Faust, Rachel January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
79

Contribution à l'étalonnage en énergie du calorimètre du GLAST-LAT et qualification des modèles de cascades hadroniques disponibles sous GEANT4.

Bregeon, Johan 30 September 2005 (has links) (PDF)
GLAST est la nouvelle génération de télescope spatial pour l'étude des rayons gamma et devrait très largement améliorer notre connaissance du ciel à haute énergie, dès son lancement en août 2007.<br />Les données du faisceau-test mené au GANIL avec des ions de basse énergie, ont permis de contribuer à l'étalonnage en énergie du LAT. Ces données ont été analysées pour mesurer la non-linéarité de la production de lumière dans le CsI en réponse au dépôt d'énergie des ions, des protons au krypton et pour des énergies allant de 0 à 73MeV par nucléon. Les résultats obtenus se sont révélés complémentaires aux mesures de scintillation du CsI, réalisées lors du faisceau-test mené au GSI pour des ions lourds relativistes . La connaissance de la non-linéarité de la réponse des cristaux de CsI de GLAST aux ions de haute énergie est indispensable pour réaliser l'étalonnage en énergie en orbite des détecteurs à l'aide des rayons cosmiques.<br /><br />Le rejet des évènements hadroniques est un autre problème clé pour GLAST, or, l'élaboration des algorithmes repose sur la simulation Monte-Carlo officielle de GLAST, GlastRelease. Les cascades hadroniques mesurées lors du faisceau-test mené au GSI et lors d'un autre faisceau-test mené au CERN sur le SPS, sont utilisées pour confronter les codes de simulation, disponibles sur la plate-forme logicielle GEANT4 qui est à la base de GlastRelease. En vérifiant la bonne reproduction de certaines observables simples, pour des cascades hadroniques générées par des protons ou de pions de .7GeV , 3.4GeV, 10GeV et 20GeV, on conclue qu'à haute énergie le modèle par défaut, LHEP, est valable, alors qu'à basse énergie, le modèle de cascade intranucléaire de Bertini devrait être utilisé.
80

Un imageur Cherenkov pour la mesure de charge des éléments du rayonnement cosmique nucléaire

Sallaz-Damaz, Yoann 29 October 2008 (has links) (PDF)
Un imageur Cherenkov, CherCam (CHERenkov CAMera), a été développé et construit pour être intégré à l'expérience CREAM (Cosmic-Ray Energetic and Mass) embarquée en ballon. Cette instrument doit permettre de mesure le charge du rayonnement cosmique nucléaire allant du protron au fer dans une gamme d'énergie s'étendant de 1E10 à 1E15 eV.<br />La thèse s'est principalement orienté sur le développement de CherCam par la création d'une simulation et de la caractérisation du plan radiateur en aérogel de silice. Mais elle s'est aussi largement étendu sur les aspects technique par la construction du détecteur et ses différents tests, ainsi que par le développement des logiciel d'étalonnage et d'analyse.

Page generated in 0.0295 seconds