21 |
Fibrinogenio, FVII, FVIII, FIX, FX e FXI como fatores de risco para tromboembolismo venoso em pacientes de uma população brasileira / Fibrinogen, FVII, FVIII, FIX, FX and FXI as risk factors for venous throembolism among patients of a Brazilian populationMello, Tayana Bezerra Teixeira 07 May 2006 (has links)
Orientador: Joyce Maria Annichinno-Bizzacchi / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-08T02:29:39Z (GMT). No. of bitstreams: 1
Mello_TayanaBezerraTeixeira_D.pdf: 2343820 bytes, checksum: be3d8e4b057cd84ec6771c67b8b1407d (MD5)
Previous issue date: 2006 / Resumo: Nos últimos anos tem sido demonstrada uma associação entre níveis elevados de certos fatores da coagulação e risco de tromboembolismo venoso (TEV). Entretanto, o número de estudos é pequeno e a maioria estão restritos a populações caucasóides. Neste estudo caso-controle emparelhado por idade, sexo e etnia investigamos os níveis plasmáticos do fibrinogênio, FVII, FVIII, FIX, FX, FXI, FvW e grupo sanguíneo (GS) ABO no risco trombótico. Foram analisados 175 pacientes com TEV (122 mulheres e 53 homens), com idade mediana de 36 anos (13-63), acompanhados no Ambulatório de Hemostasia da Unicamp no período de julho de 2002 a julho de 2005. Na análise univariada, níveis elevados de FVIII (OR: 5,3 IC95% 2,9-9,6), FvW (OR: 4,9 IC95% 2,7-8,9), FIX (OR: 2,4 IC95% 1,3-4,4), FXI (OR: 2,1 IC95% 1,1-4,0) e GS não O (OR: 3,0 IC95% 1,9-4,6) foram fatores de risco para TEV. O FVIII, FvW e GS não O foram associados ao risco tanto em membro inferior como em sítio incomum da doença. A análise de todas estas variáveis, segundo critério de seleção ¿stepwise¿, mostrou o FVIII (OR: 3,1 IC95% 1,6-6,0), FvW (OR:2,8 IC95% 1,4-5,4) e o GS não-O (OR:2,2 IC95% 1,3-3,5) como fatores de risco independentes para TEV e que o FIX e FXI agiram sinergicamente a estas variáveis no acréscimo do risco trombótico. Risco de recorrência foi conferido por elevações do FIX (OR: 4,7 IC95% 1,8-11,9) e FXI (OR: 3,4 IC95% 1,8-8,7). Os determinantes dos níveis plasmáticos do FVIII não estão totalmente esclarecidos. Como a LRP (Low density lipoprotein receptor related protein) tem um papel no catabolismo do FVIII, foram pesquisados os polimorfimos C200T, o A775P e o D2080N no gene codificador dessa proteína, como fator de risco para TEV e a influência dos mesmos sobre os níveis do FVIII e FvW. Não houve diferença nas prevalências destes polimorfismos entre pacientes e controles. No entanto, no grupo-controle, o genótipo DN, do polimorfismo D2080N, foi associado a menores concentrações do FVIII (77,4 UI/dl) e FvW (70,2 UI/dl), quando comparado ao genótipo DD (127 UI/dl e 108,4 UI/dl, respectivamente p<0,05). Em conclusão, nesta população brasileira miscigenada, o FVIII, FvW , FIX, FXI e GS não O foram associados ao risco de TEV e o polimorfismo D2080N, no gene da LRP, interferiu com os níveis plasmáticos de FVIII e FvW / Abstract: During the last years an association between high levels of certain coagulation factors and the risk for venous thromboembolism (VTE) has been demonstrated. The number of studies, however, is small, and most of them are restricted to Caucasian populations. In this case control study, matched for age, sex and ethnicity, we investigated the plasma levels of fibrinogen, FVII, FVIII, FIX, FX, FXI, vWF and the ABO blood group (BG) in the thrombotic risk. It was analyzed 175 patients with VTE (122 women and 53 men), median age 36 years (13-63), followed at the hemostasis outpatient clinic at the State University of Campinas ¿ UNICAMP, between July 2002 and July 2005. In univariate analysis, elevated levels of FVIII (OR: 5.3 95%CI 2.9-9.6), FvW (OR: 4.9 95%CI 2.7-8.9), FIX (OR: 2.4 95%CI 1.3-4.4), FXI (OR: 2.1 95%CI 1.1-4.0) and non O BG (OR: 3.0 95%CI 1.9-4.6) were risk factors for VTE. FVIII, FvW and non O BG were associated with the risk both in lower limbs and unusual sites of disease. Analysis of all these variables by stepwise selection criteria showed FVIII (OR:3.1 95%CI 1.6-6.0), FvW (OR:2.8 95%CI 1.4-5.4) and non O BG (OR:2.2 95%CI 1.3-3.5) as independent risk factors for VTE, and FIX and FXI increased synergistically the risk of thrombosis of these variables. Risk of recurrence was conferred by FIX (OR:4.7 IC95% 1.8-11.9) and FXI (OR:3.4 IC95% 1.8-8.7). The FVIII plasma levels determinants are not well established. Since LRP (Low density lipoprotein receptor related protein) has a role in the catabolism of FVIII, we evaluated the C200T, A775P and, D2080N polymorphisms in the gene coding of this protein, as risk factor for VTE and their influence upon the levels of FVIII and vWF. There was no difference regarding the prevalence of these polymorphisms between patients and controls. However, in the control group, the DN genotype, of the D2080N polymorphism, was associated with lower concentrations of FVIII (77.4 UI/dl) and vWF (70.2 UI/dl), when compared to DD genotype (127 UI/dl e 108.4 UI/dl, respectively p<0.05). In conclusion, in these Brazilian miscigenous population, increased levels of FVIII, FvW, FIX, FXI and non O BG were associated with VTE risk and the D2080N polymorphism, in the LRP gene, influenced plasma levels of FVIII and vWF / Doutorado / Biologia Estrutural, Celular, Molecular e do Desenvolvimento / Doutor em Fisiopatologia Medica
|
22 |
Determinação do genótipo RHD fetal no plasma materno: acurácia do teste semiautomatizado / Fetal RHD genotype determination in maternal plasma: Accuracy of a semi-automated testZiza, Karen Nogueira Chinoca 18 November 2015 (has links)
INTRODUÇÃO: A determinação do genótipo RHD fetal no plasma materno é um teste de diagnóstico pré-natal não invasivo oferecido a gestantes RhD negativo que apresentam potencial de sensibilização e/ou Doença Hemolítica Perinatal. Atualmente, este exame é realizado de rotina em diversos países, mas não no Brasil. A Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) oferece atendimento terciário a gestantes RhD negativo, com monitorização dos títulos de anticorpos irregulares, administração da imunoglobulina anti-D e/ou terapêutica fetal, quando necessários. OBJETIVO: Avaliar a acurácia do teste semiautomatizado para determinação do genótipo RHD fetal no plasma materno. METODOLOGIA: Foram coletadas prospectivamente amostras de sangue de 220 gestantes RhD negativo, com idade gestacional entre 8-28 semanas. O plasma foi obtido em no máximo 2 horas após a coleta, e uma alíquota de 1 mL foi submetida à extração de ácidos nucléicos no equipamento automatizado MagNA Pure Compact (Roche), empregando o kit Large Volume. O DNA extraído foi submetido a PCR em tempo real (Step One Plus - Applied Biosystems), usando o protocolo do grupo SAFE, que tem como alvos os éxons 5 e 7 do gene RHD. RESULTADOS: Ocorreu exclusão de 35 amostras devido a problemas pré-analíticos, aborto ou desconhecimento do fenótipo do recém-nascido. Entre as 185 amostras analisadas, 130 (70,2%) foram genotipadas como RHD+ e 55 (29,8%) RHD-. Os resultados obtidos foram comparados com a fenotipagem do cordão umbilical, e houve concordância completa (100%). Sete amostras exibiram amplificação exclusiva para o éxon 7. Essas amostras foram submetidas aos protocolos em PCR convencional, e PCR em tempo real específico para o pseudogene RHD. Ambos os ensaios apresentaram os mesmos resultados: cinco positivos e dois negativos. Nesses mesmos 7 casos, após extração da camada de leucócitos materna, os protocolos foram repetidos, e o resultado confirmou que cinco mães eram RHD. As duas amostras com resultado negativo foram submetidas ao protocolo Multiplex, envolvendo os éxons 3-9 do gene RHD, com resultados negativos, confirmando que as mães são verdadeiramente RHD- portanto o sinal do éxon 7 é provindo dos fetos que são D variantes. CONCLUSÃO: O método para a determinação do RHD fetal no plasma materno descrito demonstrou ser rápido, de fácil execução, alta precisão e reprodutível, além de indicar possíveis variantes RHD em nossa população / BACKGROUND: Fetal RHD genotype determination in maternal plasma is a noninvasive prenatal diagnostic test performed in RhD negative pregnant women at risk of alloimmunization and/or Hemolytic Disease of Fetus and Newborn. Currently, this test is routinely performed in many countries but not in Brazil. The Department of Obstetrics at Hospital das Clínicas, São Paulo University Medical School provides tertiary antenatal care for RhD negative pregnant women including anti-D immunoglobulin administration, antibody levels monitoring and intrauterine treatment if necessary. AIMS: To validate the accuracy of a semi-automated test for fetal RHD genotype determination in maternal plasma. METHODS: Two-hundred and twenty blood samples were prospectively collected between 8 and 28 weeks of gestational age. Plasma processing was performed within 2 hours after blood collection, and nucleic acids were extracted from 1mL aliquots with an automated extraction platform (MagNA Pure Compact Roche) and the Large Volume kit. RHD gene exons 5 and 7 were amplified with real-time PCR (Step One Plus - Applied Biosystems) using the SAFE group protocol. RESULTS: Thirty-five samples were excluded due to pre-analytical problems, miscarriage and missing follow-up. In the remaining 185 samples, 130 (70.2%) were genotyped as RhD+ and 55 (29.8%) RhD-. Comparison with umbilical cord blood group phenotype showed 100% concordance. Seven samples showed amplification for exon 7 only. These were further investigated with conventional and real-time PCR with an specific protocol for RHD? pseudogene: 5 were positive and 2, negative. In these 7 cases, maternal buffy-coat DNA analysis also confirmed that 5 women were RHD?. In the remaining 2 cases, a multiplex protocol directed at RHD gene exons 3-9 confirmed that both mothers were truly RhD negative so exon 7 signal comes from the fetuses, further found to harbor D variants. CONCLUSION: The present study demonstrates that fetal RHD determination in maternal plasma is a fast, easy-to-perform and reproducible technique with high accuracy in our population. Moreover, it helps in the identification of possible RHD variants in our population
|
23 |
Determinação do genótipo RHD fetal no plasma materno: acurácia do teste semiautomatizado / Fetal RHD genotype determination in maternal plasma: Accuracy of a semi-automated testKaren Nogueira Chinoca Ziza 18 November 2015 (has links)
INTRODUÇÃO: A determinação do genótipo RHD fetal no plasma materno é um teste de diagnóstico pré-natal não invasivo oferecido a gestantes RhD negativo que apresentam potencial de sensibilização e/ou Doença Hemolítica Perinatal. Atualmente, este exame é realizado de rotina em diversos países, mas não no Brasil. A Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HCFMUSP) oferece atendimento terciário a gestantes RhD negativo, com monitorização dos títulos de anticorpos irregulares, administração da imunoglobulina anti-D e/ou terapêutica fetal, quando necessários. OBJETIVO: Avaliar a acurácia do teste semiautomatizado para determinação do genótipo RHD fetal no plasma materno. METODOLOGIA: Foram coletadas prospectivamente amostras de sangue de 220 gestantes RhD negativo, com idade gestacional entre 8-28 semanas. O plasma foi obtido em no máximo 2 horas após a coleta, e uma alíquota de 1 mL foi submetida à extração de ácidos nucléicos no equipamento automatizado MagNA Pure Compact (Roche), empregando o kit Large Volume. O DNA extraído foi submetido a PCR em tempo real (Step One Plus - Applied Biosystems), usando o protocolo do grupo SAFE, que tem como alvos os éxons 5 e 7 do gene RHD. RESULTADOS: Ocorreu exclusão de 35 amostras devido a problemas pré-analíticos, aborto ou desconhecimento do fenótipo do recém-nascido. Entre as 185 amostras analisadas, 130 (70,2%) foram genotipadas como RHD+ e 55 (29,8%) RHD-. Os resultados obtidos foram comparados com a fenotipagem do cordão umbilical, e houve concordância completa (100%). Sete amostras exibiram amplificação exclusiva para o éxon 7. Essas amostras foram submetidas aos protocolos em PCR convencional, e PCR em tempo real específico para o pseudogene RHD. Ambos os ensaios apresentaram os mesmos resultados: cinco positivos e dois negativos. Nesses mesmos 7 casos, após extração da camada de leucócitos materna, os protocolos foram repetidos, e o resultado confirmou que cinco mães eram RHD. As duas amostras com resultado negativo foram submetidas ao protocolo Multiplex, envolvendo os éxons 3-9 do gene RHD, com resultados negativos, confirmando que as mães são verdadeiramente RHD- portanto o sinal do éxon 7 é provindo dos fetos que são D variantes. CONCLUSÃO: O método para a determinação do RHD fetal no plasma materno descrito demonstrou ser rápido, de fácil execução, alta precisão e reprodutível, além de indicar possíveis variantes RHD em nossa população / BACKGROUND: Fetal RHD genotype determination in maternal plasma is a noninvasive prenatal diagnostic test performed in RhD negative pregnant women at risk of alloimmunization and/or Hemolytic Disease of Fetus and Newborn. Currently, this test is routinely performed in many countries but not in Brazil. The Department of Obstetrics at Hospital das Clínicas, São Paulo University Medical School provides tertiary antenatal care for RhD negative pregnant women including anti-D immunoglobulin administration, antibody levels monitoring and intrauterine treatment if necessary. AIMS: To validate the accuracy of a semi-automated test for fetal RHD genotype determination in maternal plasma. METHODS: Two-hundred and twenty blood samples were prospectively collected between 8 and 28 weeks of gestational age. Plasma processing was performed within 2 hours after blood collection, and nucleic acids were extracted from 1mL aliquots with an automated extraction platform (MagNA Pure Compact Roche) and the Large Volume kit. RHD gene exons 5 and 7 were amplified with real-time PCR (Step One Plus - Applied Biosystems) using the SAFE group protocol. RESULTS: Thirty-five samples were excluded due to pre-analytical problems, miscarriage and missing follow-up. In the remaining 185 samples, 130 (70.2%) were genotyped as RhD+ and 55 (29.8%) RhD-. Comparison with umbilical cord blood group phenotype showed 100% concordance. Seven samples showed amplification for exon 7 only. These were further investigated with conventional and real-time PCR with an specific protocol for RHD? pseudogene: 5 were positive and 2, negative. In these 7 cases, maternal buffy-coat DNA analysis also confirmed that 5 women were RHD?. In the remaining 2 cases, a multiplex protocol directed at RHD gene exons 3-9 confirmed that both mothers were truly RhD negative so exon 7 signal comes from the fetuses, further found to harbor D variants. CONCLUSION: The present study demonstrates that fetal RHD determination in maternal plasma is a fast, easy-to-perform and reproducible technique with high accuracy in our population. Moreover, it helps in the identification of possible RHD variants in our population
|
24 |
Evolutionary genetics of homo neanderthalensis :adaptive traits and methodological problemsGigli, Elena 20 June 2011 (has links)
The evolutionary history of H. neanderthalensis, interwoven with that of H. sapiens, has always fascinated the scientific world. Recent adavncess in paleogenetics shedds new light on the phylogenetic relationship between Neandertals and modern humans. The studies developed in this thesis intend principally to control the contaminants through the development of an anti-contamination protocol for decreasing the human contamination in pre-laboratory phases. We designed a PCR-based method specific for reducing human contamination during the laboratory analysis, and we analyzed the fragmentation pattern of the ancient sequences by massively parallel sequencing technologies. Furthermore, we studied two nuclear genes, TAS2R38 -associated to bitter taste perception- and ABO blood group system –involved in natural immunity- that provide specific information on aspects of the Neanderthal phenotype and adaptation. / La historia evolutiva d’H. neanderthalensis, imbricada amb la d’H. sapiens, ha fascinat sempre el món científic. Avenços recents en paleogenètica aporten una nova llum sobre la rel•lació filogenètica entre els neandertals i els humans moderns. Els treballs d’aquesta tesi intenten principalment controlar els contaminants mitjançant el desenvolupament d’un protocol d’anti-contaminació que disminueixi la contaminació humana de les mostres en la fase de pre-laboratori. Hem desenvolupat un mètode basat en la PCR específic per a reduïr els contaminants humans durant l’anàlisi en el laboratori, i hem analitzat el patró de fragmentació de les seqüències antigues amb tècniques de seqüenciació massiva en paral•lel. A més a més, hem estudiat dos gens nuclears, el TAS2R38 –associat a la percepció del gust amarg- i el grup sanguini ABO –implicat en la immunitat natural- que proporcionen informació específca sobre aspectes del fenotip i de les adaptacions dels neandertals.
|
Page generated in 0.0564 seconds