1 |
High frequency chest wall oscillation as a prophylactic to upper respiratory infections for a patient in a long term care settingMull, Robert Dayton. January 1900 (has links) (PDF)
Thesis (D.PT.)--Sage Colleges, 2009. / "May 2009." "A Capstone project for PTY 768 presented to the Faculty of the Physical Therapy Department Sage Graduate School in partial fulfillment of the requirements for the degree of Doctor of Physical Therapy." Includes bibliographical references.
|
2 |
Estudo de três estratégias de ventilação artificial protetora: alta freqüência, baixa freqüência e baixa freqüência associada à insuflação de gás traqueal, em modelo experimental de SARA / Comparing three protective mechanical ventilation strategies, HFOV, low-frequency-ventilation, and low-frequency-ventilation with TGI, in an ARDS experimental modelVolpe, Márcia Souza 09 February 2007 (has links)
Introdução: Um dos principais objetivos na SARA é encontrar a melhor estratégia protetora de ventilação mecânica que minimize o stress pulmonar e otimize as trocas gasosas. Teoricamente, estas duas metas podem ser obtidas simultaneamente, evitando-se a hiperdistensão e colapso cíclico de unidades alveolares instáveis. Numa tentativa de radicalizar a minimização da hiperdistensão e da pressão motriz inspiratória, duas estratégias podem ser propostas: o uso da ventilação de alta freqüência oscilatória (HFOV) e o uso da insuflação intra-traqueal de gás (TGI), esta última associada à hipercapnia permissiva e baixas freqüências respiratórias. Objetivo: identificar qual (quais) entre as três estratégias de ventilação mecânica, HFOV, TGI e ventilação protetora de baixa freqüência (VP: volume corrente ~6 mL/kg), foi (foram) a (s) mais protetora (s) em um modelo de SARA em coelhos, durante seis horas de ventilação mecânica. Material e métodos: Os animais (n = 45) foram submetidos a repetidas lavagens pulmonar até uma PaO2 < 100 mmHg. Imediatamente após a injuria pulmonar, foi obtida uma curva P/V para calculo do trabalho inspiratório e energia dissipada durante insuflação pulmonar. Em seguida, os animais foram randomizados em um dos três grupos: HFOV, VP ou TGI. O PEEP ou PMEAN ideais foram obtidos através de uma curva PEEP/PaO2 (ou PMEAN/PaO2) que foi precedida por uma manobra de recrutamento. Os animais dos grupos VP e TGI foram inicialmente ventilados em PCV com um delta de pressão = 8 cmH2O e freqüência = 60 resp/min. A única diferença inicial entre os dois foi que o grupo TGI possuía um fluxo traqueal continuo = 1 L/min. Os animais do grupo HFOV foram inicialmente ventilados com uma amplitude de pressão = 45 cmH2O e freqüência = 10 Hz. Todos os animais foram ventilados com uma FiO2 = 1.0. Os deltas de pressão (ou pressão motriz) nos grupos VP e TGI foram reajustados para manter uma PaCO2 = 90-110 mmHg, enquanto no HFOV a amplitude de pressão foi reajustada para manter uma PaCO2 = 45-55 mmHg. No final do experimento, outra curva P/V foi obtida. Amostras do LBA e sangue foram coletados antes e após o período de ventilação para determinar os níveis de IL-8. Amostras do pulmão esquerdo foram processadas para análise histológica e para cálculo da relação peso-úmido/ peso-seco. Resultados: Não foi observada diferença na PaO2 entre os grupos. A PaCO2 foi significantemente menor no grupo HFOV (59 ± 3 mmHg) quando comparado aos grupos VP (99 ± 4 mmHg) e TGI (80 ± 3 mmHg). O volume corrente foi significantemente menor nos grupos TGI e HFOV quando comparado ao grupo VP. Logo após a lesão pulmonar, todos os grupos necessitaram de trabalhos similares para a insuflação pulmonar, mas o grupo VP foi o único que não apresentou melhora (diminuição) deste trabalho expiratório, a estratégia VP foi a única que apresentou aumento ao longo das 6 horas (P<0,001). Os grupos TGI e HFOV também apresentaram maiores concentrações de polimorfonucleares no tecido pulmonar (P=0,008) e tendências a favorecer um maior índice superfície/volume (P=0,14), maior gradiente IL-8 (diferença ente IL-8 no LBA e plasma - P=0,08) e menor relação peso-úmido/peso-seco (P=0,17) ao final das 6 horas de ventilação. Discussão: O menor trabalho requerido na insuflação pulmonar depois de 6 horas de ventilação refletiu uma redução nas pressões críticas de abertura e, provavelmente, uma melhora do edema pulmonar e do sistema surfactante nas estratégias HFOV e TGI. O aumento do trabalho expiratório no grupo VP sugere, inclusive, uma deterioração na qualidade do surfactante neste grupo. Nos grupos TGI e HFO, a maior concentração de polimorfonucleares no tecido pulmonar e a tendência a apresentar maior gradiente de IL8 poderiam se interpretados como uma melhor membrana alvéolo-capilar, resultando na menor liberação de mediadores compartimentalizados no interior dos alvéolos. Além de necessitar volumes correntes mais altos, a estratégia VP necessitou de pressões inspiratórias progressivamente mais altas durante as seis horas de protocolo, devido a reajustes freqüentes, necessários à manutenção das trocas gasosas. Conclusão: Uma redução mais radical das pressões motrizes demonstrou efeitos benéficos num modelo de lesão pulmonar aguda experimental, mesmo quando associada a uma estratégia que já prioriza o recrutamento pulmonar ótimo. O TGI mostrou ser uma alternativa viável à HFOV, apresentando algumas vantagens práticas de implementação e em termos de previsibilidade de resposta nas trocas gasosas. / Introduction: One of the major goals in ARDS is to find the best protective mechanical ventilation strategy, which minimizes lung stress and optimizes gas exchange. Theoretically, these two goals can be accomplished by simultaneously avoiding alveolar overdistension and cyclic collapse of unstable alveolar units. Pushing further the rationale of this strategy, two new strategies have been proposed: high frequency oscillatory mechanical ventilation (HFOV) and intra-tracheal gas insufflation (TGI) associated with permissive hypercapnia and conventional frequencies. Objective: To determine which of the three protective modalities of mechanical ventilation, HFOV, low-frequency-protective ventilation (LFV), or LFV associated with tracheal gas insufflation (TGI), was the most protective strategy in an ARDS rabbit model during six hours of mechanical ventilation. Material and methods: The animals (n = 45) were submitted to repeated saline lavage until PaO2 < 100 mmHg. Immediately after lung injury, a P/V curve was obtained to calculate inspiratory/expiratory work and energy dissipated during lung inflation. Thereafter, the animals were randomized into one of three groups: LFV, HFOV or TGI. The optimal PEEP or PMEAN was obtained during a PEEP/PaO2 (or PMEAN/PaO2) curve which was preceded by a recruiting maneuver. The animals of the LFV and TGI groups were initially ventilated in PCV with diving pressure = 8 cmH2O and frequency = 60 b/m. The only initial difference between these two arms was that the TGI group had a continuous tracheal flow = 1 L/min. The animals in the HFOV were initially ventilated with an oscillatory pressure amplitude = 45 cmH2O and frequency = 10 Hz. All animals were ventilated with FiO2 = 1.0. Driving pressure was then adjusted in LFV and TGI groups to maintain a PaCO2 = 90-110 mmHg, while in HFO the pressure amplitude was adjusted to maintain a PaCO2 = 45-55 mmHg. At the end of the experiment, after 6 hours of ventilation, another P/V curve was obtained. BAL and bloods samples were drawn before and after the period of ventilation to determine IL-8 levels. The left lung was processed for histological analysis and for wet weight/dry weight (ww/dw) ratio. Results: We observed no differences in PaO2 among the groups. PaCO2 was significantly lower at HFO (59 ± 3 mmHg) when compared with LFV (99 ± 4 mmHg) and TGI (80 ± 3 mmHg) groups. Tidal volume was significantly lower in TGI and HFO groups when compared with LFV group. Soon after injury, all groups required similar energy for lung inflation (inspiratory work), but the VP group was the only one not presenting any improvement in this parameter after 6 hours (P<0.001). Concerning the expiratory work, the VP strategy was the only one presenting an increase in the expiratory work along the 6 hours (P<0.001). The TGI and HFOV groups showed the highest polymorphonuclear cell concentration in lung tissue (P=0.008) and trends towards a higher surface/volume index (P=0.14), higher IL8 gradient (difference between IL8 in BAL and plasma) and lower ww/dw ratio at the end of 6 hours of ventilation (P=0.17). Discussion: The lower energy for lung inflation after six hours of ventilation reflected the reduction of opening pressures and better surfactant function during ventilation under TGI and HFOV strategies. The increase in expiratory work during the VP strategy further suggests that the surfactant quality deteriorated under this strategy. In the TGI and HFOV groups, the higher concentration of polymorphonuclear cells and the trend towards a higher IL8 gradient between the lung and blood may suggest a better integrity of the alveolar-capillary membrane, leading to less release of compartmentalized mediators within the alveolar space. Besides the higher tidal volumes used during VP, this strategy required inspiratory pressures progressively higher along the hours, due to frequent and necessary adjustments of tidal volumes or pressures according to the gas-exchange requirements. Conclusion: An aggressive reduction of tidal volume and driving pressures was beneficial during protective strategies, even when an optimization of lung recruitment was already in place. The TGI strategy showed to be an attractive alternative to HFOV, presenting some advantages in terms of implementation and predictability of response.
|
3 |
Estudo de três estratégias de ventilação artificial protetora: alta freqüência, baixa freqüência e baixa freqüência associada à insuflação de gás traqueal, em modelo experimental de SARA / Comparing three protective mechanical ventilation strategies, HFOV, low-frequency-ventilation, and low-frequency-ventilation with TGI, in an ARDS experimental modelMárcia Souza Volpe 09 February 2007 (has links)
Introdução: Um dos principais objetivos na SARA é encontrar a melhor estratégia protetora de ventilação mecânica que minimize o stress pulmonar e otimize as trocas gasosas. Teoricamente, estas duas metas podem ser obtidas simultaneamente, evitando-se a hiperdistensão e colapso cíclico de unidades alveolares instáveis. Numa tentativa de radicalizar a minimização da hiperdistensão e da pressão motriz inspiratória, duas estratégias podem ser propostas: o uso da ventilação de alta freqüência oscilatória (HFOV) e o uso da insuflação intra-traqueal de gás (TGI), esta última associada à hipercapnia permissiva e baixas freqüências respiratórias. Objetivo: identificar qual (quais) entre as três estratégias de ventilação mecânica, HFOV, TGI e ventilação protetora de baixa freqüência (VP: volume corrente ~6 mL/kg), foi (foram) a (s) mais protetora (s) em um modelo de SARA em coelhos, durante seis horas de ventilação mecânica. Material e métodos: Os animais (n = 45) foram submetidos a repetidas lavagens pulmonar até uma PaO2 < 100 mmHg. Imediatamente após a injuria pulmonar, foi obtida uma curva P/V para calculo do trabalho inspiratório e energia dissipada durante insuflação pulmonar. Em seguida, os animais foram randomizados em um dos três grupos: HFOV, VP ou TGI. O PEEP ou PMEAN ideais foram obtidos através de uma curva PEEP/PaO2 (ou PMEAN/PaO2) que foi precedida por uma manobra de recrutamento. Os animais dos grupos VP e TGI foram inicialmente ventilados em PCV com um delta de pressão = 8 cmH2O e freqüência = 60 resp/min. A única diferença inicial entre os dois foi que o grupo TGI possuía um fluxo traqueal continuo = 1 L/min. Os animais do grupo HFOV foram inicialmente ventilados com uma amplitude de pressão = 45 cmH2O e freqüência = 10 Hz. Todos os animais foram ventilados com uma FiO2 = 1.0. Os deltas de pressão (ou pressão motriz) nos grupos VP e TGI foram reajustados para manter uma PaCO2 = 90-110 mmHg, enquanto no HFOV a amplitude de pressão foi reajustada para manter uma PaCO2 = 45-55 mmHg. No final do experimento, outra curva P/V foi obtida. Amostras do LBA e sangue foram coletados antes e após o período de ventilação para determinar os níveis de IL-8. Amostras do pulmão esquerdo foram processadas para análise histológica e para cálculo da relação peso-úmido/ peso-seco. Resultados: Não foi observada diferença na PaO2 entre os grupos. A PaCO2 foi significantemente menor no grupo HFOV (59 ± 3 mmHg) quando comparado aos grupos VP (99 ± 4 mmHg) e TGI (80 ± 3 mmHg). O volume corrente foi significantemente menor nos grupos TGI e HFOV quando comparado ao grupo VP. Logo após a lesão pulmonar, todos os grupos necessitaram de trabalhos similares para a insuflação pulmonar, mas o grupo VP foi o único que não apresentou melhora (diminuição) deste trabalho expiratório, a estratégia VP foi a única que apresentou aumento ao longo das 6 horas (P<0,001). Os grupos TGI e HFOV também apresentaram maiores concentrações de polimorfonucleares no tecido pulmonar (P=0,008) e tendências a favorecer um maior índice superfície/volume (P=0,14), maior gradiente IL-8 (diferença ente IL-8 no LBA e plasma - P=0,08) e menor relação peso-úmido/peso-seco (P=0,17) ao final das 6 horas de ventilação. Discussão: O menor trabalho requerido na insuflação pulmonar depois de 6 horas de ventilação refletiu uma redução nas pressões críticas de abertura e, provavelmente, uma melhora do edema pulmonar e do sistema surfactante nas estratégias HFOV e TGI. O aumento do trabalho expiratório no grupo VP sugere, inclusive, uma deterioração na qualidade do surfactante neste grupo. Nos grupos TGI e HFO, a maior concentração de polimorfonucleares no tecido pulmonar e a tendência a apresentar maior gradiente de IL8 poderiam se interpretados como uma melhor membrana alvéolo-capilar, resultando na menor liberação de mediadores compartimentalizados no interior dos alvéolos. Além de necessitar volumes correntes mais altos, a estratégia VP necessitou de pressões inspiratórias progressivamente mais altas durante as seis horas de protocolo, devido a reajustes freqüentes, necessários à manutenção das trocas gasosas. Conclusão: Uma redução mais radical das pressões motrizes demonstrou efeitos benéficos num modelo de lesão pulmonar aguda experimental, mesmo quando associada a uma estratégia que já prioriza o recrutamento pulmonar ótimo. O TGI mostrou ser uma alternativa viável à HFOV, apresentando algumas vantagens práticas de implementação e em termos de previsibilidade de resposta nas trocas gasosas. / Introduction: One of the major goals in ARDS is to find the best protective mechanical ventilation strategy, which minimizes lung stress and optimizes gas exchange. Theoretically, these two goals can be accomplished by simultaneously avoiding alveolar overdistension and cyclic collapse of unstable alveolar units. Pushing further the rationale of this strategy, two new strategies have been proposed: high frequency oscillatory mechanical ventilation (HFOV) and intra-tracheal gas insufflation (TGI) associated with permissive hypercapnia and conventional frequencies. Objective: To determine which of the three protective modalities of mechanical ventilation, HFOV, low-frequency-protective ventilation (LFV), or LFV associated with tracheal gas insufflation (TGI), was the most protective strategy in an ARDS rabbit model during six hours of mechanical ventilation. Material and methods: The animals (n = 45) were submitted to repeated saline lavage until PaO2 < 100 mmHg. Immediately after lung injury, a P/V curve was obtained to calculate inspiratory/expiratory work and energy dissipated during lung inflation. Thereafter, the animals were randomized into one of three groups: LFV, HFOV or TGI. The optimal PEEP or PMEAN was obtained during a PEEP/PaO2 (or PMEAN/PaO2) curve which was preceded by a recruiting maneuver. The animals of the LFV and TGI groups were initially ventilated in PCV with diving pressure = 8 cmH2O and frequency = 60 b/m. The only initial difference between these two arms was that the TGI group had a continuous tracheal flow = 1 L/min. The animals in the HFOV were initially ventilated with an oscillatory pressure amplitude = 45 cmH2O and frequency = 10 Hz. All animals were ventilated with FiO2 = 1.0. Driving pressure was then adjusted in LFV and TGI groups to maintain a PaCO2 = 90-110 mmHg, while in HFO the pressure amplitude was adjusted to maintain a PaCO2 = 45-55 mmHg. At the end of the experiment, after 6 hours of ventilation, another P/V curve was obtained. BAL and bloods samples were drawn before and after the period of ventilation to determine IL-8 levels. The left lung was processed for histological analysis and for wet weight/dry weight (ww/dw) ratio. Results: We observed no differences in PaO2 among the groups. PaCO2 was significantly lower at HFO (59 ± 3 mmHg) when compared with LFV (99 ± 4 mmHg) and TGI (80 ± 3 mmHg) groups. Tidal volume was significantly lower in TGI and HFO groups when compared with LFV group. Soon after injury, all groups required similar energy for lung inflation (inspiratory work), but the VP group was the only one not presenting any improvement in this parameter after 6 hours (P<0.001). Concerning the expiratory work, the VP strategy was the only one presenting an increase in the expiratory work along the 6 hours (P<0.001). The TGI and HFOV groups showed the highest polymorphonuclear cell concentration in lung tissue (P=0.008) and trends towards a higher surface/volume index (P=0.14), higher IL8 gradient (difference between IL8 in BAL and plasma) and lower ww/dw ratio at the end of 6 hours of ventilation (P=0.17). Discussion: The lower energy for lung inflation after six hours of ventilation reflected the reduction of opening pressures and better surfactant function during ventilation under TGI and HFOV strategies. The increase in expiratory work during the VP strategy further suggests that the surfactant quality deteriorated under this strategy. In the TGI and HFOV groups, the higher concentration of polymorphonuclear cells and the trend towards a higher IL8 gradient between the lung and blood may suggest a better integrity of the alveolar-capillary membrane, leading to less release of compartmentalized mediators within the alveolar space. Besides the higher tidal volumes used during VP, this strategy required inspiratory pressures progressively higher along the hours, due to frequent and necessary adjustments of tidal volumes or pressures according to the gas-exchange requirements. Conclusion: An aggressive reduction of tidal volume and driving pressures was beneficial during protective strategies, even when an optimization of lung recruitment was already in place. The TGI strategy showed to be an attractive alternative to HFOV, presenting some advantages in terms of implementation and predictability of response.
|
4 |
Dynamic Modelling of the Patient Circuit for High Frequency Ventilation / Modellering av patientkretsen för högfrekvent mekanisk ventilationEriksson, Samuel January 2022 (has links)
Artificial breathing is vital when it comes to treatment of critically ill patients where the natural breathing mechanism is insufficient. With the help of mechanical ventilators, the natural breathing mechanism of the patient can be assisted or even exchanged with the artificial breathing from the machine. Small errors and unexpected events in these systems may lead to serious damages on the patients, causing even more harm than good. Therefore, these systems require a lot of testing and monitoring to ensure functionality. With the use of accurate simulation models, testing time can be reduced by running test in the simulation environment instead of on the actual machine. The simulation models can also be used for monitoring functions in real time, making sure the ventilation of the patient is working as expected. When it comes to simulating a ventilator system controlled with high frequency ventilation techniques, the existing simulation models fail to reproduce the high frequency dynamics that appear during high frequency ventilation. This paper proposes a modelling approach for mechanical ventilator systems exposed to high frequency dynamics. Focus is placed on modeling the patient circuit including the inspiratory and expiratory tubes, the humidifier with the dry line tube, the Y-piece, the tracheal tube and the patient lungs. The model is based on mathematical models representing the thermodynamic and pneumatic behaviour of the system. It is built using Simulink with regular and customized building blocks from Simscape. Compared to pre-existing simulation models, this model includes the inertia effects of the gas which is crucial when it comes to accurately modeling the system while being exposed to fast changes in flow and pressure. To evaluate the model performance, the simulated pressure and flow at the patient port are compared to measured data from an experimental setup. From the results of this thesis it was seen that the model is very sensitive to the patient model used in the simulation environment, which means that the patient model has to be remodeled in order to archive a better model performance. Compared to the pre-existing model used for comparison in this thesis, it is seen that an increased parameter model produces more accurate results. / Konstgjord andning är livsavgörande när det kommer till behandling av kritiskt sjuka patienter där den naturliga andningsmekanismen inte fungerar som den ska. Med hjälp av mekanisk ventilation kan den naturliga andningsmekanismen hos patienten assisteras eller helt ersättas av denna konstgjorda andning. Små fel eller oväntade händelser i dessa system kan vara livsfarliga för patienten och kan orsaka mer skada än nytta. Detta gör att dessa system kräver mycket testning och övervakning för att säkerställa att allt fungerar som tänkt. Med hjälp av noggranna simuleringsmodeller kan testtiden minskas samtidigt som dessa simuleringsmodeller kan användas för övervakning av systemet i realtid, detta för att säkerställa systemets funktion. När det kommer till simulering av ventilatorsystem som ventileras med högfrekventa ventilationstekniker, misslyckas de befintliga simuleringsmodellerna att återskapa den högfrekventa dynamik som uppstår under högfrekvent ventilation. Denna uppsatts föreslår en modelleringsmetod för att kunna modellera mekaniska ventilatorsystem som utsätts för högfrekvent dynamik. Fokus för projektet har varit att modellera patientkretsen inklusive inandnings- och utandningsslangarna, luftfuktaren med torrlinjeslangen, Y-kopplingen, trakealtuben och patientens lungor. Modellen är baserad på matematiska modeller som representerar systemets termodynamiska och pneumatiska beteende. Den är byggd i Simulink med existerande och anpassade block från Simscape. Jämfört med redan existerande simuleringsmodeller inkluderar denna modell gasens tröghetseffekter, vilket är avgörande när det gäller att noggrant modellera systemet samtidigt som det utsätts för snabba förändringar i flöde och tryck. För att utvärdera modellens prestanda jämförs det simulerade trycket och flödet vid patientporten med uppmätta data från en experimentell uppställning i labbmiljö. Resultaten från detta projekt visar att modellen är väldigt känslig för patientmodellen som används i simuleringsmiljön, vilket innebär att patientmodellen måste rekonstrueras för att uppnå en bättre prestanda för modellen. Jämfört med den redan existerande modellen som används för jämförelse i denna avhandling, syns det att en ökad parametermodell ger ett resultat närmare de uppmätta signalerna från det verkliga systemet.
|
5 |
Efeitos fisiológicos da ventilação de alta frequência usando ventilador convencional em um modelo experimental de insuficiência respiratória grave / Physiological effects of high frequency ventilation with conventional ventilator in an experimental model of severe respiratory failureCordioli, Ricardo Luiz 30 July 2012 (has links)
Introdução: A Síndrome do Desconforto Respiratório Agudo (SDRA) apresenta alta incidência e mortalidade em pacientes de terapia intensiva. A ventilação mecânica é o principal suporte para os pacientes que apresentam-se com SDRA, entretanto ainda existe muito debate sobre a melhor estratégia ventilatória a ser adotada, pois a ventilação mecânica pode ser lesiva aos pulmões e aumentar a mortalidade se mal ajustada. Um dos principais mecanismos de lesão pulmonar induzida pela ventilação é o uso de volumes correntes altos, havendo evidência na literatura que a utilização de volumes correntes menores fornece uma ventilação dita protetora, a qual aumenta a probabilidade de sobrevivência. Objetivo: Explorar se uma estratégia ventilatória de alta frequência com pressão positiva (HFPPV) realizada através de um ventilador mecânico convencional (Servo-300) é capaz de permitir uma maior redução do volume corrente e estabilização da PaCO2 em um modelo de SDRA severa, inicialmente ventilado com uma estratégia protetora. Métodos: Estudo prospectivo, experimental que utilizou oito porcos que foram submetidos a uma lesão pulmonar através de lavagem pulmonar com soro fisiológico e ventilação mecânica lesiva. Em seguida, os animais foram ventilados com um volume corrente de 6 mL/kg, seguido de uma randomização de sequências diferentes de frequências respiratórias (30, 60, 60 com pausa inspiratória de 10 e 30%, 90, 120, 150, 60 com manobra de recrutamento alveolar mais titulação da PEEP e HFOV com 5 Hertz), até obter estabilização da PaCO2 entre 57 63 mmHg por 30 minutos. O ventilador Servo-300 foi utilizado para HFPPV e o ventilador SensorMedics 3100B utilizado para fornecer a ventilação oscilatória de alta frequência (HFOV). Dados são apresentados como mediana [P25th,P75th]. Principais Resultados: O peso dos animais foi de 34 [29,36] kg. Após a lesão pulmonar, a relação P/F, o shunt pulmonar e a complacência estática dos animais ficaram em 92 [63,118] mmHg, 26 [17,31] % e 11 [8,14] mL/cmH2O respectivamente. O PEEP total usado foi de 14 [10,17] cmH2O durante o experimento. Da frequência respiratória de 35 (e com volume corrente de 6 mL/kg) até a frequência ventilatória de 150 rpm, a PaCO2 foi 81 [78,92] mmHg para 60 [58,63] mmHg (P=0.001), o volume corrente (VT) progressivamente caiu de 6.1 [5.9,6.2] para 3.8 [3.7,4.2] mL/kg (P<0.001), a pressão de platô de 29 [26,30] para 27 [25,29] cmH2O (P=0.306) respectivamente. Não houve nenhum comprometimento hemodinâmico ou da oxigenação, enquanto os animais utilizaram a FiO2 = 1. Conclusões: Utilizando-se de uma ventilação mecânica protetora, a estratégia de HFPPV realizada com um ventilador mecânico convencional em um modelo animal de SDRA severa permitiu maior redução do volume corrente, bem como da pressão de platô. Esta estratégia também permitiu a manutenção de PaCO2 em níveis clinicamente aceitáveis / Introduction: Acute respiratory distress syndrome (ARDS) has a high incidence and mortality between critical ill patients. The mechanical ventilation is the most important support for these patients with ARDS. However, until now there is an important debate about how is the best ventilatory strategy to use, because the mechanical ventilation if not well set can cause lung injury and increase mortality. The use of high tidal volume is one of the most important mechanics of ventilation induced lung injury and there is evidence in the literature that using low tidal volume is a protective ventilation with better survival. Objective: To explore if high frequency positive pressure ventilation (HFPPV) delivered by a conventional ventilator (Servo-300) is able to allow further tidal volume reductions and to stabilize PaCO2 in a severe acute respiratory distress syndrome (ARDS) model initially ventilated with a protective ventilation. Methods: A prospective and experimental laboratory study where eight Agroceres pigs were instrumented and followed by induction of acute lung injury with sequential pulmonary lavages and injurious ventilation. Afterwards, the animals were ventilated with a tidal volume of 6 mL/kg, followed by a randomized sequence of respiratory rates (30, 60, 60 with pauses of 10 and 30% of the inspiratory time, 90, 120, 150, 60 with alveolar recruitment maneuver and PEEP titration and 5 Hertz of HFOV), until PaCO2 stabilization between 57 63 mmHg for 30 minutes. The Servo-300 ventilator was used for HFPPV and the ventilator SensorMedics 3100B was used for HFOV. Data are shown as median (P25th,P75th). Measurements and Main Results: Animals weight was 34 [29,36] kg. After lung injury, the P/F ratio, pulmonary shunt and static compliance of animals were 92 [63,118] mmHg, 26 [17,31] % and 11 [8,14] mL/cmH2O respectively. The total PEEP used was 14 [10,17] cmH2O throughout the experiment. From the respiratory rates of 35 (while ventilating with 6 mL/kg) to 150 breaths/ minute, the PaCO2 was 81 [78,92] mmHg and 60 [58,63] mmHg (P=0.001), the tidal volume progressively felt from 6.1 [5.9,6.2] to 3.8 [3.7,4.2] mL/kg (P<0.001), the plateau pressure was 29 [26,30] and 27[25,29] cmH2O (P=0.306) respectively. There were no detrimental effects in the hemodynamics and blood oxygenation, while the animals were using a FiO2 = 1. Conclusions: During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model allows further tidal volume reductions. This strategy also allowed the maintenance of PaCO2 in clinically acceptable levels
|
6 |
Efeitos fisiológicos da ventilação de alta frequência usando ventilador convencional em um modelo experimental de insuficiência respiratória grave / Physiological effects of high frequency ventilation with conventional ventilator in an experimental model of severe respiratory failureRicardo Luiz Cordioli 30 July 2012 (has links)
Introdução: A Síndrome do Desconforto Respiratório Agudo (SDRA) apresenta alta incidência e mortalidade em pacientes de terapia intensiva. A ventilação mecânica é o principal suporte para os pacientes que apresentam-se com SDRA, entretanto ainda existe muito debate sobre a melhor estratégia ventilatória a ser adotada, pois a ventilação mecânica pode ser lesiva aos pulmões e aumentar a mortalidade se mal ajustada. Um dos principais mecanismos de lesão pulmonar induzida pela ventilação é o uso de volumes correntes altos, havendo evidência na literatura que a utilização de volumes correntes menores fornece uma ventilação dita protetora, a qual aumenta a probabilidade de sobrevivência. Objetivo: Explorar se uma estratégia ventilatória de alta frequência com pressão positiva (HFPPV) realizada através de um ventilador mecânico convencional (Servo-300) é capaz de permitir uma maior redução do volume corrente e estabilização da PaCO2 em um modelo de SDRA severa, inicialmente ventilado com uma estratégia protetora. Métodos: Estudo prospectivo, experimental que utilizou oito porcos que foram submetidos a uma lesão pulmonar através de lavagem pulmonar com soro fisiológico e ventilação mecânica lesiva. Em seguida, os animais foram ventilados com um volume corrente de 6 mL/kg, seguido de uma randomização de sequências diferentes de frequências respiratórias (30, 60, 60 com pausa inspiratória de 10 e 30%, 90, 120, 150, 60 com manobra de recrutamento alveolar mais titulação da PEEP e HFOV com 5 Hertz), até obter estabilização da PaCO2 entre 57 63 mmHg por 30 minutos. O ventilador Servo-300 foi utilizado para HFPPV e o ventilador SensorMedics 3100B utilizado para fornecer a ventilação oscilatória de alta frequência (HFOV). Dados são apresentados como mediana [P25th,P75th]. Principais Resultados: O peso dos animais foi de 34 [29,36] kg. Após a lesão pulmonar, a relação P/F, o shunt pulmonar e a complacência estática dos animais ficaram em 92 [63,118] mmHg, 26 [17,31] % e 11 [8,14] mL/cmH2O respectivamente. O PEEP total usado foi de 14 [10,17] cmH2O durante o experimento. Da frequência respiratória de 35 (e com volume corrente de 6 mL/kg) até a frequência ventilatória de 150 rpm, a PaCO2 foi 81 [78,92] mmHg para 60 [58,63] mmHg (P=0.001), o volume corrente (VT) progressivamente caiu de 6.1 [5.9,6.2] para 3.8 [3.7,4.2] mL/kg (P<0.001), a pressão de platô de 29 [26,30] para 27 [25,29] cmH2O (P=0.306) respectivamente. Não houve nenhum comprometimento hemodinâmico ou da oxigenação, enquanto os animais utilizaram a FiO2 = 1. Conclusões: Utilizando-se de uma ventilação mecânica protetora, a estratégia de HFPPV realizada com um ventilador mecânico convencional em um modelo animal de SDRA severa permitiu maior redução do volume corrente, bem como da pressão de platô. Esta estratégia também permitiu a manutenção de PaCO2 em níveis clinicamente aceitáveis / Introduction: Acute respiratory distress syndrome (ARDS) has a high incidence and mortality between critical ill patients. The mechanical ventilation is the most important support for these patients with ARDS. However, until now there is an important debate about how is the best ventilatory strategy to use, because the mechanical ventilation if not well set can cause lung injury and increase mortality. The use of high tidal volume is one of the most important mechanics of ventilation induced lung injury and there is evidence in the literature that using low tidal volume is a protective ventilation with better survival. Objective: To explore if high frequency positive pressure ventilation (HFPPV) delivered by a conventional ventilator (Servo-300) is able to allow further tidal volume reductions and to stabilize PaCO2 in a severe acute respiratory distress syndrome (ARDS) model initially ventilated with a protective ventilation. Methods: A prospective and experimental laboratory study where eight Agroceres pigs were instrumented and followed by induction of acute lung injury with sequential pulmonary lavages and injurious ventilation. Afterwards, the animals were ventilated with a tidal volume of 6 mL/kg, followed by a randomized sequence of respiratory rates (30, 60, 60 with pauses of 10 and 30% of the inspiratory time, 90, 120, 150, 60 with alveolar recruitment maneuver and PEEP titration and 5 Hertz of HFOV), until PaCO2 stabilization between 57 63 mmHg for 30 minutes. The Servo-300 ventilator was used for HFPPV and the ventilator SensorMedics 3100B was used for HFOV. Data are shown as median (P25th,P75th). Measurements and Main Results: Animals weight was 34 [29,36] kg. After lung injury, the P/F ratio, pulmonary shunt and static compliance of animals were 92 [63,118] mmHg, 26 [17,31] % and 11 [8,14] mL/cmH2O respectively. The total PEEP used was 14 [10,17] cmH2O throughout the experiment. From the respiratory rates of 35 (while ventilating with 6 mL/kg) to 150 breaths/ minute, the PaCO2 was 81 [78,92] mmHg and 60 [58,63] mmHg (P=0.001), the tidal volume progressively felt from 6.1 [5.9,6.2] to 3.8 [3.7,4.2] mL/kg (P<0.001), the plateau pressure was 29 [26,30] and 27[25,29] cmH2O (P=0.306) respectively. There were no detrimental effects in the hemodynamics and blood oxygenation, while the animals were using a FiO2 = 1. Conclusions: During protective mechanical ventilation, HFPPV delivered by a conventional ventilator in a severe ARDS swine model allows further tidal volume reductions. This strategy also allowed the maintenance of PaCO2 in clinically acceptable levels
|
7 |
Characterization of mass transport in the upper human airwaysBauer, Katrin 22 February 2012 (has links) (PDF)
Mechanical ventilation can be a life saving treatment. However, due to the inhomogeneous and anisotropic behavior of the lung tissue, ventilation can also lead to overdistensions of lung regions whereas other areas remain even collapsed. A first step is a more comprehensive understanding of the flow mechanics under normal breathing conditions in a healthy lung as well as for a diseased, collapsed lung. This is the aim of this work. Therefore, a realistic model of the upper human airways has been generated at which experimental and numerical investigations could be carried out. Experimentally, the flow was analyzed by means of Particle Image Velocimetry (PIV) measurements which revealed new details about the flow patterns occurring during different ventilation frequencies. Numerical results were in good agreement with the experimental results and could provide new details about the three-dimensional flow structure and emerging secondary flow within the upper airways. The study of reopening of collapsed airways has shown that larger frequencies lead to airway reopening without overdistension of already open parts. Higher frequencies also lead to homogenization of mass flow distribution within the human lung. / Künstliche Beatmung ist meist eine lebensrettende Maßnahme. Aufgrund der räumlich anisotropen und inhomogenen Eigenschaften der Lunge kann die Beatmung jedoch auch zu einer Schädigung der Lunge führen. Daraus ergibt sich die Forderung einer „Protektiven Beatmung“. Ein erster Schritt dahingehend ist ein verbessertes Verständnis der Atmung und Beatmung am Beispiel der gesunden sowie kranken, teilweise kollabierten Lunge. Dies ist das Ziel der Arbeit. Hierfür wurde ein realistisches Modell der oberen Atemwege (Tracheobronchialbaum) angefertigt. An diesem Modell können sowohl experimentelle als auch numerische Untersuchungen durchgeführt werden. Experimentell wurde die Strömung mittels Particle Image Velocimetry (PIV) untersucht, wobei neue Details bezüglich der auftretenden Strömungsmuster für unterschiedliche Frequenzen gefunden wurden. Numerische Strömungsberechnungen stimmen gut mit den experimentellen Ergebnissen überein. Dreidimensionale Strömungsstrukturen sowie die Entwicklung von Sekundärwirbeln in der Lunge konnten erklärt werden. Eine Studie am kranken, teilweise kollabierten Lungenmodell zeigte, dass mit steigender Frequenz kollabierte Bereiche wiedereröffnet werden können. Höhere Frequenzen führen weiterhin zu einer Homogenisierung der Massenstromverteilung in der Lunge.
|
8 |
Characterization of mass transport in the upper human airwaysBauer, Katrin 06 December 2011 (has links)
Mechanical ventilation can be a life saving treatment. However, due to the inhomogeneous and anisotropic behavior of the lung tissue, ventilation can also lead to overdistensions of lung regions whereas other areas remain even collapsed. A first step is a more comprehensive understanding of the flow mechanics under normal breathing conditions in a healthy lung as well as for a diseased, collapsed lung. This is the aim of this work. Therefore, a realistic model of the upper human airways has been generated at which experimental and numerical investigations could be carried out. Experimentally, the flow was analyzed by means of Particle Image Velocimetry (PIV) measurements which revealed new details about the flow patterns occurring during different ventilation frequencies. Numerical results were in good agreement with the experimental results and could provide new details about the three-dimensional flow structure and emerging secondary flow within the upper airways. The study of reopening of collapsed airways has shown that larger frequencies lead to airway reopening without overdistension of already open parts. Higher frequencies also lead to homogenization of mass flow distribution within the human lung. / Künstliche Beatmung ist meist eine lebensrettende Maßnahme. Aufgrund der räumlich anisotropen und inhomogenen Eigenschaften der Lunge kann die Beatmung jedoch auch zu einer Schädigung der Lunge führen. Daraus ergibt sich die Forderung einer „Protektiven Beatmung“. Ein erster Schritt dahingehend ist ein verbessertes Verständnis der Atmung und Beatmung am Beispiel der gesunden sowie kranken, teilweise kollabierten Lunge. Dies ist das Ziel der Arbeit. Hierfür wurde ein realistisches Modell der oberen Atemwege (Tracheobronchialbaum) angefertigt. An diesem Modell können sowohl experimentelle als auch numerische Untersuchungen durchgeführt werden. Experimentell wurde die Strömung mittels Particle Image Velocimetry (PIV) untersucht, wobei neue Details bezüglich der auftretenden Strömungsmuster für unterschiedliche Frequenzen gefunden wurden. Numerische Strömungsberechnungen stimmen gut mit den experimentellen Ergebnissen überein. Dreidimensionale Strömungsstrukturen sowie die Entwicklung von Sekundärwirbeln in der Lunge konnten erklärt werden. Eine Studie am kranken, teilweise kollabierten Lungenmodell zeigte, dass mit steigender Frequenz kollabierte Bereiche wiedereröffnet werden können. Höhere Frequenzen führen weiterhin zu einer Homogenisierung der Massenstromverteilung in der Lunge.
|
Page generated in 0.157 seconds