• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • 2
  • 1
  • Tagged with
  • 11
  • 11
  • 11
  • 7
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Study of Limited-Diffraction Array Beam and Steered Plane Wave Imaging

Wang, Jing 20 June 2006 (has links)
No description available.
2

High Speed CMOS Image Sensor

January 2016 (has links)
abstract: High speed image sensors are used as a diagnostic tool to analyze high speed processes for industrial, automotive, defense and biomedical application. The high fame rate of these sensors, capture a series of images that enables the viewer to understand and analyze the high speed phenomena. However, the pixel readout circuits designed for these sensors with a high frame rate (100fps to 1 Mfps) have a very low fill factor which are less than 58%. For high speed operation, the exposure time is less and (or) the light intensity incident on the image sensor is less. This makes it difficult for the sensor to detect faint light signals and gives a lower limit on the signal levels being detected by the sensor. Moreover, the leakage paths in the pixel readout circuit also sets a limit on the signal level being detected. Therefore, the fill factor of the pixel should be maximized and the leakage currents in the readout circuits should be minimized. This thesis work presents the design of the pixel readout circuit suitable for high speed and low light imaging application. The circuit is an improvement to the 6T pixel readout architecture. The designed readout circuit minimizes the leakage currents in the circuit and detects light producing a signal level of 350µV at the cathode of the photodiode. A novel layout technique is used for the pixel, which improves the fill factor of the pixel to 64.625%. The read out circuit designed is an integral part of high speed image sensor, which is fabricated using a 0.18 µm CMOS technology with the die size of 3.1mm x 3.4 mm, the pixel size of 20µm x 20 µm, number of pixel of 96 x 96 and four 10-bit pipelined ADC’s. The image sensor achieves a high frame rate of 10508 fps and readout speed of 96 M pixels / sec. / Dissertation/Thesis / Masters Thesis Electrical Engineering 2016
3

Development of novel ultrasound techniques for imaging and elastography : from simulation to real-time implementation / Sviluppo di tecniche originali ad ultrasuoni per applicazioni di imaging ed elastografia : dalla simulazione all'implementazione in tempo reale / Développement de nouvelles techniques ultrasonores pour des applications d’imagerie ou d’élastographie : de la simulation à l'implémentation temps-réel

Ramalli, Alessandro 02 April 2012 (has links)
Les techniques ultrasonores offrent de nombreux avantages, à la fois par leur utilisation facile et la sécurité du patient. De plus, la recherche, visant à étendre les possibles champs d’applications, est particulièrement active. Cependant, l’accès à des équipements adaptés et supportant des logiciels est conditio sine qua non pour l’expérimentation de nouvelles techniques. Ce projet de thèse traite des problématiques de traitement du signal et d'image dans un contexte d'imagerie médicale et vise à répondre à deux objectifs scientifiques: le premier consiste à contribuer au développement d'une puissante plateforme de recherche (ULA-OP) alors que le second a pour objectif d'introduire et de valider, grâce à cette plateforme, des méthodes de traitement non-standard qui ne pourraient pas être évaluées avec des équipements médicaux commerciaux. ULA-OP, un équipement recherche qui donne accès aux développeurs à une grande liberté de contrôle et de configuration l’ensemble des parties actives du système, de la transmission aux traitements des signaux échographiques. Il offre aussi la possibilité d’accéder aux signaux bruts à n’importe quel niveau de la chaîne de réception. Durant cette thèse, les capacités du système ont été améliorées en implémentant des outils logiciels comme des simulateurs de champ acoustique (propagation linéaire et non-linéaire), et en développant des programmes de génération de signaux post-échographique. L’ULA-OP a été crucial pour développer et tester différentes techniques non-standard telles qu’un schéma adaptatif de formation de voie et une méthode d’imagerie Doppler couleur/vecteur, qui seront détaillés dans le manuscrit. En particulier, une nouvelle méthode a été développée pour des applications d’élastographie quasi-statique. Cette méthode, basée sur un algorithme d’estimation du mouvement dans le domaine fréquentiel et combinée à une méthode d’imagerie haute fréquence, a permis d’améliorer la qualité des élastogrammes obtenus. Cette nouvelle méthode a d’abord été testée in-vitro par des traitements hors ligne des signaux reçus et pour ensuite être implémentée en temps réel sur le ULA-OP. Les résultats obtenus montrent que cette technique est performante et que les élastogrammes présentent une qualité supérieure comparée à ceux obtenues avec les méthodes connues de la littérature / Ultrasound techniques offer many advantages, in terms of both ease of realization and patients’ safety. The research aimed at expanding the fields of application, is nowadays particularly active. The availability of suitable hardware and supporting software tools is condicio sine qua non for the experimentation of new techniques. This Ph.D project addresses signal/image processing issues in medical ultrasound and seeks to achieve two major scientific goals: the first is to contribute to the development of a powerful ultrasound research platform (ULA¬OP), while the second is introducing and validating, through this platform, non-standard methods which could not be tested with commercial equipment. ULA-OP is a research system, which gives developers great freedom in terms of management and control of every section, from signal transmission to echo-signal processing; it also offers the possibility to access raw data at any point in the receive chain. During the thesis, the capabilities of the system were improved by creating advanced software tools, such as acoustic field simulators (for linear and nonlinear propagation), and by developing echo-signals post-elaboration programs. ULA-OP was crucial to develop and test various non-standard techniques such as an adaptive beamforming scheme and a color/vector Doppler imaging method, which will be detailed in this thesis. In particular, a novel technique was developed for quasi-static elastography applications. This technique, based on a frequency domain displacement estimation algorithm, combined with a high-frame-rate averaging method, aims at improving the quality of the elastograms. The new method was first tested in-vitro by offline processing the received signals, and then it was implemented in real-time on ULA-OP. The results show that this technique is effective and that the obtained elastograms present higher quality compared with those obtained with standard algorithms
4

Ultrafast ultrasound imaging for simultaneous extraction of flow and arterial wall motion with linear array probe / Imagerie ultrasonore rapide pour l'extraction simultanée du flux et du mouvement pariétal en géométrie linéaire

Perrot, Vincent 23 October 2019 (has links)
Cette thèse présente un ensemble de travaux qui s'inscrivent dans le domaine du génie biomédical pour des applications cliniques. L'objectif principal de ce travail est de fournir aux cliniciens un mode d'imagerie ultrasonore pour extraire simultanément la vitesse du flux et le mouvement de la paroi à des cadences d'imagerie élevées dans les artères. Les pathologies cardiovasculaires sont une cause majeure de décès et d'invalidité dans le monde. Bien que l'origine de ces maladies ne soit pas encore entièrement comprise, il semble que certains marqueurs pathologiques de la paroi et du flux pourraient permettre une détection plus précoce. Parce que les tissus artériels sont sujets à des phénomènes rapides et complexes, une modalité d'imagerie à haute cadence semble très pertinente pour étudier les pathologies du système cardiovasculaire. Malheureusement, aucune technique n'est actuellement utilisée cliniquement ni même approuvée pour l'extraction de marqueurs pathologiques du sang et de la paroi à des cadences d'imagerie élevées. C'est pourquoi, dans cette thèse, je propose de concevoir une séquence et un algorithme ultrasonore permettant d'extraire ces deux aspects, à des cadences d'imagerie élevées sur les artères, pour une application clinique potentielle. Trois contributions scientifiques principales sont présentées cette thèse : i) la conception de la séquence ultrasonore avec un estimateur de mouvement 2D, ii) une nouvelle approche adaptative de filtrage de paroi, et iii) un essai clinique. La séquence d'imagerie ultrasonore est basée sur la transmission d'ondes planes permettant d'obtenir des cadences d'imagerie allant jusqu'à 10 000 Hz sur la carotide. La méthode d'estimation de mouvement est basée sur une approche introduisant une oscillation latérale virtuelle dans les images qui, couplée à un estimateur de phase 2D basé sur des travaux antérieurs de la littérature, permet d'extraire des champs vectoriels de vitesses. Les validations pour l'estimation des vitesses du flux et du mouvement des parois ont été effectuées à l'aide d'un fantôme d'écoulement Doppler commercial et d'un fantôme de carotide réaliste conçu pour les expériences. Une technique de filtrage adaptatif de paroi a été développée et validée sur des volontaires à l'aide des estimations de vitesses tissulaires, ce qui permet d'éliminer précisément le signal du tissu des signaux du sang. Enfin, l'essai clinique a été réalisé à l'hôpital avec un groupe de volontaires et un groupe de patients. La séquence ultrasonore, l'algorithme d'estimation de mouvement et les approches adaptatives de filtrage de paroi ont été validés dans la thèse. La méthode permet d'extraire les vitesses du flux et de la paroi à haute cadence d'imagerie, avec de faibles erreurs et écarts-types. L'approche adaptative du filtrage de paroi permet de mieux extraire le flux par rapport à d'autres approches standard. Cette amélioration est particulièrement perceptible à proximité de la paroi, ce qui permettrait des mesures précises de l'écoulement et des contraintes le long des parois artérielles où les plaques peuvent se former et se développer. Pour conclure, l'essai clinique a démontré la faisabilité de notre approche dans un environnement clinique avec l'extraction des mouvements tissulaires, du flux et de paramètres artériels qui ont montré des différences entre et au sein des groupes. Cette thèse est donc un pas en avant vers l'utilisation clinique de l'imagerie ultrasonore à haute cadence pour la quantification du mouvement tissulaire et du flux pour la détection et le diagnostic des maladies cardiovasculaires / This thesis is focused on biomedical engineering for clinical applications. The main goal of this work is to provide to clinicians an ultrasound mode to simultaneously extract wall motion and flow at high frame rates in arteries. Cardiovascular pathologies are a major cause of death and disability worldwide. Although the formation of such diseases is still not fully understood, it appears that some pathological markers from both wall and flow could allow an earlier detection. Because tissues are subject to fast and complex phenomena in the arteries, a high frame rate imaging modality seems highly relevant to extract as much information as possible on the condition of the cardiovascular system. Unfortunately, no technique is currently clinically used or even approved for the extraction of both flow and wall pathological markers at high frame rates. Therefore, in this thesis, I propose to design an ultrasound sequence and algorithm permitting to extract both aspects, at high frame rates on arteries, for a potential clinical application. There are three main scientific contributions in this thesis: i) the design of the ultrasound sequence with a 2D motion estimator, ii) a new adaptive clutter filtering approach, and iii) a clinical trial. The ultrasound sequence is based on plane wave acquisition permitting to yield frame rates up to 10 000 Hz in the carotid. The pipeline used an approach introducing a virtual lateral oscillation in ultrasound images which, coupled with a 2D phase-based estimator based on previous works from the literature, allows to extract vectorial velocity fields. Validations for both flow and wall motion estimation were performed on a commercial Doppler flow phantom and an in-house realistic carotid phantom was designed for the experiments. An adaptive clutter filtering technique was also developed and validated on volunteers based on tissue estimates, which permit to precisely remove tissue clutter from flow signals. Finally, the clinical trial was performed at the hospital with a group of volunteers and a group of patients. The ultrasound sequence, motion estimation algorithm, and adaptive clutter filtering approaches were well validated in the thesis. The method can provide both wall motion and flow estimates at high frame rates, with low errors and standard deviations. The adaptive clutter filtering approach permits to better extract the flow compared to other standard approaches. This improvement is especially noticeable close to the wall, which would allow accurate flow and stress measurements along arterial walls where plaques can form and develop. To conclude, the clinical trial has demonstrated the feasibility in a clinical environment with the extraction of wall motion, flow, and arterial parameters that showed differences between and within groups. This thesis is then a step toward clinical use of high frame rate ultrasound imaging for quantification of both wall motion and flow for pathological detection of cardiovascular diseases
5

Imagerie ultrasonore ultra-rapide dédiée à la quantification 3D du mouvement cardiaque / Ultrafast ultrasound imaging for 3-D cardiac motion estimation

Joos, Philippe 22 December 2017 (has links)
Cette thèse porte sur le développement et l’évaluation de techniques d’imagerie en échocardiographie. L’objectif est de proposer des méthodes d’imagerie ultrasonore ultrarapide pour estimer le mouvement cardiaque 2-D et 3-D.Première modalité d’imagerie du cœur, l’échocardiographie conventionnelle permet la mesure des déformations myocardiques à 80 images/s. Cette cadence d’imagerie est insuffisante pour quantifier les mouvements de la totalité du myocarde lors de tests d’efforts, utiles en évaluation clinique, au cours desquels le rythme cardiaque est augmenté. De plus, la résolution temporelle actuelle en échocardiographie 3-D limite ses applications, pourtant essentielles pour une caractérisation complète du cœur.Les contributions présentées ici sont 1) le développement et l’évaluation, pour l’application cardiaque, d’une méthode originale d’estimation de mouvement 2-D par imagerie ultrarapide et marquage des images, 2) l’étude de faisabilité de la mesure globale des déformations cardiaques avec une méthode innovante d’imagerie ultrasonore ultrarapide 2-D et 3) la généralisation de cette approche en 3-D pour l’imagerie des volumes cardiaques à haute résolution temporelle. Cette technique est basée sur l’émission d’ondes divergentes, et l’intégration d’une compensation de mouvement dans le processus de formation des volumes cardiaques.La méthode proposée permet l’estimation des mouvements cardiaques 2-D et l’échocardiographie ultrarapide 3-D. L’évaluation de notre approche pour la quantification des déformations myocardiques locales 2-D et 3-D pourrait permettre de proposer des pistes innovantes pour poursuivre nos études et améliorer le diagnostic en routine clinique / This PhD work focuses on the development and the evaluation of imaging techniques in echocardiography. Our objective is to propose ultrafast ultrasound imaging methods for 2-D and 3-D cardiac motion estimations.Echocardiography is one of the most widespread modality for cardiovascular imaging. Conventional clinical scanners allow measurement of myocardial velocities and deformations at 80 images / s. In some situations, it can be recommended to increase the heart rate during a stress echocardiographic examination. Motion estimation of the whole myocardium at such heart rates is challenging with the conventional imaging systems. In addition, the low temporal resolution of the current conventional 3-D echocardiography limits quantitative applications, which would be needed for a complete characterization of the heart.The three contributions presented here are 1) the development and evaluation of an original method for 2-D cardiac motion estimation, with ultrafast imaging and image tagging, 2) the feasibility study of the global myocardial deformation measurement using an innovative 2-D ultrafast ultrasound imaging method and 3) the generalization of this approach in three dimensions for high frame-rate 3-D echocardiography. This method is based on the transmission of divergent waves and the integration of motion compensation, during the imaging process, to produce high-quality volumetric images of the heart.The proposed method allows 2-D cardiac motion estimation and 3-D echocardiography at high frame-rate. The evaluation of our approach for local 2-D and 3-D myocardial deformation measurements should permit to conduct further study in order to improve medical diagnosis
6

Development and validation of innovative ultrasound flow imaging methods / Développement et validation de nouvelles méthodes d'imagerie du flux par ultrasons

Lenge, Matteo 17 March 2015 (has links)
L'échographie est largement utilisée pour l'imagerie du flux sanguin pour ses nombreux avantages tels que son inocuité, son cout réduit, sa facilité d'utilisation et ses performances. Cette thèse a pour objectif de proposer de nouvelles méthodes ultrasonores d'imagerie du flux sanguin. Après une étude bibliographique, plusieurs approches ont été étudiées en détail jusqu'à leur implémentation sur l'échographe de recherche ULA-OP développé au sein du laboratoire et ont été validées en laboratoire et en clinique. La transmission d'ondes planes a été proposée pour améliorer la technique d'imagerie utilisant les oscillations transverses. Des champs de pression ultrasonores présentant des oscillations transverses sont générés dans de larges régions et exploités pour l'estimation vectorielle du flux sanguin à une haute cadence d'imagerie. Des cartes du flux sanguin sont obtenues grâce à une technique s'appuyant sur la transmission d'ondes planes couplées à un nouvel algorithme d'estimation de la vitesse dans le domaine fréquentiel. Les méthodes vectorielles implémentées en temps réel dans le ULA-OP ont été comparées à la méthode Doppler classique lors d'une étude clinique. Les résultats ont montré le bénéfice des méthodes vectorielles en termes de précision et de répétabilité. La nouvelle méthode proposée a démontré sa grande précision ainsi que son gain en termes de temps de calcul aussi bien en simulations qu'en acquisitions en laboratoire ou lors d'essais in vivo. Une solution logicielle temps réel implémentée sur une carte GPU a été proposée et testée afin de réduire encore le temps de calcul et permettre l'emploi de la méthode en clinique / Ultrasound is widely used for blood flow imaging because of the considerable advantages for the clinician, in terms of performance, costs, portability, and ease of use, and for the patient, in terms of safety and rapid checkup. The undesired limitations of conventional methods (1-D estimations and low frame-rate) are widely overtaken by new vector approaches that offer detailed descriptions of the flow for a more accurate diagnosis of cardiovascular system diseases. This PhD project concerns the development of novel methods for blood flow imaging. After studying the state-of-the-art in the field, a few approaches have been examined in depth up to their experimental validation, both in technical and clinical environments, on a powerful ultrasound research platform (ULA-OP). Real-time novel vector methods implemented on ULA-OP were compared to standard Doppler methods in a clinical study. The results attest the benefits of the vector methods in terms of accuracy and repeatability. Plane-wave transmissions were exploited to improve the transverse oscillation imaging method. Double oscillating fields were produced in large regions and exploited for the vectorial description of blood flow at high frame rates. Blood flow maps were obtained by plane waves coupled to a novel velocity estimation algorithm operating in the frequency domain. The new method was demonstrated capable of high accuracy and reduced computational load by simulations and experiments (also in vivo). The investigation of blood flow inside the common carotid artery has revealed the hemodynamic details with unprecedented quality. A software solution implemented on a graphic processing unit (GPU) board was suggested and tested to reduce the computational time and support the clinical employment of the method
7

Dense Stereo Reconstruction in a Field Programmable Gate Array

Sabihuddin, Siraj 30 July 2008 (has links)
Estimation of depth within an imaged scene can be formulated as a stereo correspondence problem. Software solutions tend to be too slow for high frame rate (i.e. > 30 fps) performance. Hardware solutions can result in marked improvements. This thesis explores one such hardware implementation that generates dense binocular disparity estimates at frame rates of over 200 fps using a dynamic programming formulation (DPML) developed by Cox et. al. A highly parameterizable field programmable gate array implementation of this architecture demonstrates equivalent accuracy while executing at significantly higher frame rates to those of current approaches. Existing hardware implementations for dense disparity estimation often use sum of squared difference, sum of absolute difference or other similar algorithms that typically perform poorly in comparison to DPML. The presented system runs at 248 fps for a resolution of 320 x 240 pixels and disparity range of 128 pixels, a performance of 2.477 billion DPS.
8

Dense Stereo Reconstruction in a Field Programmable Gate Array

Sabihuddin, Siraj 30 July 2008 (has links)
Estimation of depth within an imaged scene can be formulated as a stereo correspondence problem. Software solutions tend to be too slow for high frame rate (i.e. > 30 fps) performance. Hardware solutions can result in marked improvements. This thesis explores one such hardware implementation that generates dense binocular disparity estimates at frame rates of over 200 fps using a dynamic programming formulation (DPML) developed by Cox et. al. A highly parameterizable field programmable gate array implementation of this architecture demonstrates equivalent accuracy while executing at significantly higher frame rates to those of current approaches. Existing hardware implementations for dense disparity estimation often use sum of squared difference, sum of absolute difference or other similar algorithms that typically perform poorly in comparison to DPML. The presented system runs at 248 fps for a resolution of 320 x 240 pixels and disparity range of 128 pixels, a performance of 2.477 billion DPS.
9

Caractérisation de vortex intraventriculaires par échographie Doppler ultrarapide

Faurie, Julia 07 1900 (has links)
Les maladies cardiaques sont une cause majeure de mortalité dans le monde (la première cause en Amérique du nord [192]), et la prise en charge de ses maladies entraîne des coûts élevés pour la société. La prévalence de l’insuffisance cardiaque augmente fortement avec l’âge, et, avec une population vieillissante, elle va demeurer une préoccupation croissante dans le futur, non seulement pour les pays industrialisés mais aussi pour ceux en développement. Ainsi il est important d’avoir une bonne compréhension de son mécanisme pour obtenir des diagnostics précoces et un meilleur prognostic pour les patients. Parmi les différentes formes d’insuffisance cardiaque, on trouve la dysfonction diastolique qui se traduit par une déficience du remplissage du ventricule. Pour une meilleure compréhension de ce mécanisme, de nombreuses études se sont intéressées au mouvement du sang dans le ventricule. On sait notamment qu’au début de la diastole le flux entrant prend la forme d’un anneau vortical (ou vortex ring). La formation d’un vortex ring par le flux sanguin après le passage d’une valve a été décrite pour la première fois en 1513 par Léonard de Vinci (Fig. 0.1). En effet après avoir moulé l’aorte dans du verre et ajouter des graines pour observer le flux se déplaçant dans son fantôme, il a décrit l’apparition du vortex au passage de la valve aortique. Ces travaux ont pu être confirmés 500 ans plus tard avec l’apparition de l’IRM [66]. Dans le ventricule, le même phénomène se produit après la valve mitrale, c’est ce qu’on appelle le vortex diastolique. Or, le mouvement d’un fluide (ici le sang) est directement relié a son environnement : la forme du ventricule, la forme de la valve, la rigidité des parois... L’intérêt est donc grandissant pour étudier de manière plus approfondie ce vortex diastolique qui pourrait apporter de précieuses informations sur la fonction diastolique. Les modalités d’imagerie permettant de le visualiser sont l’IRM et l’échographie. Cette thèse présente l’ensemble des travaux effectués pour permettre une meilleure caractérisation du vortex diastolique dans le ventricule gauche par imagerie ultrasonore Doppler. Pour suivre la dynamique de ce vortex dans le temps, il est important d’obtenir une bonne résolution temporelle. En effet, la diastole ventriculaire dure en moyenne 0.5 s pour un coeur humain au repos, une cadence élevée est donc essentielle pour suivre les différentes étapes de la diastole. La qualité des signaux Doppler est également primordiale pour obtenir une bonne estimation des vitesses du flux sanguin dans le ventricule. Pour étudier ce vortex, nous nous sommes intéressés à la mesure de sa vorticité en son centre v et à l’évolution de cette dernière dans le temps. Le travail se divise ainsi en trois parties, pour chaque un article a été rédigé : 1. Développement d’une séquence Doppler ultrarapide : La séquence se base sur l’utilisation d’ondes divergentes qui permettent d’atteindre une cadence d’image élevée. Associée à la vortographie, une méthode pour localiser le centre du vortex diastolique et en déduire sa vorticité, nous avons pu suivre la dynamique de la vorticité dans le temps. Cette séquence a permis d’établir une preuve de concept grâce à des acquisitions in vitro et in vivo sur des sujets humains volontaires. 2. Développement d’une séquence triplex : En se basant sur la séquence ultrarapide Doppler, on cherche ici à ajouter des informations supplémentaires, notamment sur le mouvement des parois. La séquence triplex permet non seulement de récupérer le mouvement sanguin avec une haute cadence d’images mais aussi le Doppler tissulaire. Au final, nous avons pu déduire les Doppler couleur, tissulaire, et spectral, en plus d’un Bmode de qualité grâce à la compensation de mouvement. On peut alors observer l’interdépendance entre la dynamique du vortex et celle des parois, en récupérant tous les indices nécessaires sur le même cycle cardiaque avec une acquisition unique. 3. Développement d’un filtre automatique : La quantification de la vorticité dépend directement des vitesses estimées par le Doppler. Or, en raison de leur faible amplitude, les signaux sanguins doivent être filtrés. En effet lors de l’acquisition les signaux sont en fait une addition des signaux sanguins et tissulaires. Le filtrage est une étape essentielle pour une estimation précise et non biaisée de la vitesse. La dernière partie de ce doctorat s’est donc concentrée sur la mise au point d’un filtre performant qui se base sur les dimensions spatiales et temporelles des acquisitions. On effectue ainsi un filtrage du tissu mais aussi du bruit. Une attention particulière a été portée à l’automatisation de ce filtre avec l’utilisation de critères d’information qui se basent sur la théorie de l’information. / Heart disease is one of the leading causes of death in the world (first cause in North America [192]), and causes high health care costs for society. The prevalence of heart failure increases dramatically with age and, due to the ageing of the population, will remain a major concern in the future, not only for developed countries, but also for developing countries. It is therefore crucial to have a good understanding of its mechanism to obtain an early diagnosis and a better prognosis for patients. Diastolic dysfunction is one of the variations of heart failure and leads to insufficient filling of the ventricle. To better understand the dysfunction, several studies have examined the blood motion in the ventricle. It is known that at the beginning of diastole, the filling flow creates a vortex pattern known as a vortex ring. This development of the ring by blood flow after passage through a valve was first described in 1513 by Leonardo Da Vinci (Fig. 0.1). After molding a glass phantom in an aorta and adding seeds to visually observe the flow through the phantom, he could describe the vortex ring development of the blood coming out of the aortic valve. His work was confirmed 500 years later with the emergence of MRI [66]. The same pattern can be observed in the left ventricle when the flow emerges from the mitral valve, referred to as the diastolic vortex. The flow motion (in our case the blood) is directly related to its environment : shape of the ventricle, shape of the valve, stiffness of the walls... There is therefore a growing interest in further studies on this diastolic vortex that could lead to valuable information on diastolic function. The imaging modalities which can be used to visualize the vortex are MRI and ultrasound. This thesis presents the work carried out to allow a better characterization of the diastolic vortex in the left ventricle by Doppler ultrasound imaging. For temporal monitoring of vortex dynamics, a high temporal resolution is required, since the ventricular diastole is about 0.5 s on average for a resting human heart. The quality of Doppler signals is also of utmost importance to get an accurate estimate of the blood flow velocity in the ventricle. To study this vortex, we focused on evaluating the core vorticity evaluation and especially on its evolution in time. The work is divided in three parts, and for each of them an article has been written : 1. Ultrafast Doppler sequence : The sequence is based on diverging waves, which resulted in a high frame rate. In combination with vortography, a method to locate the vortex core and derive its vorticity, the vortex dynamics could be tracked over time. This ix sequence could establish a proof of concept based on in vitro and in vivo acquisitions on healthy human volunteers. 2. Triplex sequence : Based on the ultrafast sequence, we were interested in adding information on the wall motion. The triplex sequence is able to recover not only the blood motion with a high framerate but also tissue Doppler. In the end, we could derive color, tissue, and spectral Doppler, along with a high quality Bmode by using motion compensation. The interdependence between vortex and walls dynamics could be highlighted by acquiring all the required parameters over a single cardiac cycle. 3. Automatic clutter filter : Vorticity quantification depends directly on the estimation of Doppler velocity. However, due to their low amplitude, blood signals must be filtered. Indeed, acquired signals are actually an addition of tissue and blood signals. Filtering is a critical step for an unbiased and accurate velocity estimation. The last part of this doctoral thesis has focused on the design of an efficient filter that takes advantage of the temporal and spatial dimensions of the acquisitions. Thus the tissue alongside the noise is removed. Particular care was taken to automatize the filter by applying information criteria based on information theory.
10

Evaluating and Correcting 3D Flash LiDAR Imagers

Reinhardt, Andrew David 09 August 2021 (has links)
No description available.

Page generated in 0.0579 seconds