• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 246
  • 234
  • 87
  • 57
  • 42
  • 37
  • 11
  • 11
  • 11
  • 10
  • 10
  • 8
  • 4
  • 4
  • 4
  • Tagged with
  • 949
  • 480
  • 216
  • 128
  • 119
  • 103
  • 99
  • 98
  • 76
  • 71
  • 68
  • 65
  • 64
  • 64
  • 64
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Otimização e validação de metodologia analítica para determinação de metais e semimetais em efluentes líquidos por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Optimization and validation of analytical methodology for determination of metals and semimetals in wastewater by inductively coupled plasma optical emission spectrometry (ICP-OES)

Joyce Rodrigues Marques 24 November 2015 (has links)
Além da Resolução CONAMA 430/11 definir limites para o lançamento de efluentes, também define que os laboratórios que realizam análises ambientais devem ser acreditados pelo INMETRO e também devem ter sistema de controle de qualidade implantado. Para o atendimento destes requisitos legais, o presente trabalho visa otimizar, validar e implantar a metodologia analítica desenvolvida e aplicada no Centro de Química e Meio Ambiente (CQMA) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/ CNEN SP) para a quantificação dos elementos cádmio, chumbo, cobre, prata, crômio, zinco, estanho, níquel, ferro, bário, manganês e boro em amostras de efluentes líquidos por Espectrometria de Emissão Óptica com Plasma Acoplado Indutivamente (ICP-OES). Esta metodologia é utilizada para a determinação de metais e semimetais em amostras coletadas no Programa de Monitoramento Ambiental PMA-Q do IPEN. Todo o processo de validação desta dissertação foi baseado no guia Orientativo do INMETRO DOQ-CGCRE-008 - Orientação sobre Validação de Métodos Analíticos. No estudo de seletividade verificou-se que a matriz não interfere nas curvas analíticas do método em estudo; a faixa de trabalho foi determinada com base nos valores máximos permitidos (VMP) pelas legislações ambientais vigentes (Resolução CONAMA 430/11, DE 8.468/76 e DE 15.425/80) e no histórico de dados do PMA-Q e todas as curvas analíticas apresentam comportamento linear na faixa de trabalho abrangida pelo método; os limites de detecção e quantificação do método atendem aos limites definidos pelas legislações ambientais vigentes e à precisão e exatidão necessárias; a precisão e exatidão apresentaram resultados satisfatórios para a finalidade do método analítico; além do método demonstrar-se robusto, embora seja necessário que o analista se atente à variação de alguns fatores no momento da realização das análises. Também foi possível realizar a estimativa de incerteza do método de modo que fosse alcançado nível de confiança de 95% dos resultados, foram levadas em consideração todas as etapas de preparo e análise das amostras e foi possível obter incerteza global entre 4,6% e 12,23%. Através dos resultados obtidos nos testes estatísticos e pela avaliação do analista foi possível verificar que o método desenvolvido e aplicado no CQMA é adequado para o fim pretendido. / Beyond define limits to wastewater release, CONAMA Resolution n° 430/11 also define that laboratories, which perform environmental analysis, have to be accredited by INMETRO and must have quality control system deployed. In order to meet this legal requirements, this work aims to optimize, validate and deploy the analytical methodology developed and applied at the Centre of Environmental Science and Technology (CQMA) at Nuclear and Energy Research Institute (IPEN/ CNEN - SP), to the determination of the elements: cadmium, lead, copper, chromium, zinc, tin, nickel, iron, barium, manganese and boron in wastewater samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This methodology is used to the determination of metals and semimetals in samples collected in the IPENs Environmental Monitoring Program PMA-Q. The entire process of validation in this dissertation relied on INMETRO guide DOQ-CGCRE- 008 Guidance for Validation of Analytical Methods. In the selectivity test it was possible to verify that the matrix cause no interferences in the calibration curves of the studied method; the working range determined was based on the Maximum Allowed Values (VMP) defined by the current environmental legislations (CONAMA Resolution 430/11, State Decree 8.468/76 and State Decree 15.425/80) and in the historical data from PMA-Q and all calibration curves presented linear behavior; the detection and quantification limits of this method also attend to the requirements of the current environmental legislation and to the required precision and accuracy; the precision and accuracy presented suitable results for the methodology objective; additionally, the analytical method presented satisfactory robustness, although the responsible for the test have to have attention to any instabilities in some factors. The measurement uncertainty was estimated as well, in order to obtain results with 95% of confidence, all steps of preparation and analysis of the samples were considered and was possible to reach global uncertainty between 4,6% and 12,23%. Through the results obtained in the statistics tests and the analyst evaluation, was possible to conclude that the analytical methodology developed at CQMA is adequate to the intended purpose.
122

Desenvolvimento e validação de metodologia para determinação de metais em amostras de água por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Development and validation of methodology for determination of metals in water samples by optical emission with argon plasma spectrometry (ICP-OES)

Mainara Generoso Faustino 05 November 2015 (has links)
Para atender a legislação ambiental do Conselho Nacional do Meio Ambiente (CONAMA), a Resolução CONAMA 357/2005, é necessário desenvolver metodologias que se aplicam na medição analítica de forma correta e para um controle de qualidade é necessário a aplicação da validação de metodologia. Para atender as exigências legais, o presente trabalho desenvolveu uma metodologia para a identificação de 12 elementos metálicos, tais como: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na e Ni em águas, avaliando 14 pontos, sendo eles GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distribuídos pela Represa Guarapiranga, situada no Estado de São Paulo, aplicando a metodologia validade, realizada com base no guia do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), Orientação sobre Validação de Métodos Analíticos - DOQ-CGCE-008. Foram avaliados os parâmetros: seletividade, faixa de trabalho/linearidade, limites de detecção e quantificação, tendência/recuperação, precisão, robustez e incerteza de medição. Foi utilizado a técnica de espectrometria de Emissão Óptica com Plasma de Argônio (ICP-OES). O teste de seletividade comprovou que a matriz não interfere nas curvas analíticas elaborada; a faixa de trabalho apresentou um comportamento linear, para as amostras com e sem a matriz de interesse, com um coeficiente de correlação (r), entre 0,9965 a 1,0; os limites de detecção e quantificação do método atendem aos valores máximos permitidos pela Resolução CONAMA 357/2005; com os testes de repetitividade e de recuperação o método demonstrou ser preciso e exato, além de robusto. Posteriormente foi estimado uma incerteza de medição do método. A incerteza expandida estimada variou entre 3 e 18% da concentração encontrada. A validação da metodologia permitiu a sua aplicação para a avaliação da distribuição dos 12 elementos, nas águas da represa Guarapiranga. Foram observados valores altos para Ca, Na e K, em todos os pontos de coletas analisados, evidenciando que são os elementos que fazem parte da característica geológica da área. Os elementos Fe e Al obtiveram valores acima da legislação nos pontos da Represa (G000-01, G000-02 e G000-03). Com os testes dos parâmetros para a validação, com os cálculos estatísticos aplicados, foi possível desenvolver e aplicar uma metodologia adequada para o uso pretendido. / To attend the environmental legislation of the National Environmental Council (CONAMA) CONAMAs Resolution 357/2005, it is necessary to develop methodologies that apply the analytical measurement correctly and to a quality control application of the methodology validation is required. To attend legal requirements, this study developed a methodology for identifying 12 metals, such as: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na and Ni in water in 14 points, being them GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distributed by Guarapiranga dam, in the State of São Paulo, applying the methodology of validation based on the National Institute of Metrology, Quality and Technology (INMETRO) guide, \"Guidance on Analytical Methods Validation - DOQCGCE- 008\". The parameters analyzed were: selectivity, working range/linearity, limits of detection and quantification, tendency/recovery, accuracy, robustness and measurement uncertainty. Was used the optical emission with argon plasma spectrometry (ICP-OES) technique. The selectivity test proved that the matrix does not interfere with elaborate analytical curves; the elaborate working range obtained demonstrate a linear behavior for samples with and without the matrix of interest, with a coefficient of correlation (r) between 0,9965 and 1,0; limits of detection and quantification of this method meet the maximum values allowed by CONAMA Resolution 357/2005; with repeatability of tests and recovery method proved to be precise and accurate, and robust. It was subsequently estimated uncertainty of measurement method. The estimated expanded uncertainty varied between 3 and 18% of the concentration found. The validation of the methodology allowed the application for the evaluation of the distribution of 12 elements in Guarapiranga dam waters. Were observed high values for Ca, Na and K, at every point analyzed collections, showing, which are, the elements that are part of the geological characteristic of the area. The iron and aluminum elements obtained values above the law in points Dam (G000-01, G000-02 and G000-03). With the parameters for the validation tests, with the statistical calculations applied, it was possible to develop and apply a methodology appropriate for the intended use.
123

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using icp-oes technique

Tavares, Angélica Tamião 29 November 2013 (has links)
Os radiofármacos são preparações farmacêuticas, que contém radionuclídeo, utilizados em medicina nuclear. O objetivo desse trabalho foi estudar as concentrações de elementos químicos, principalmente metais, em amostras de radiofármacos ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDATEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-Flúor-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. As análises foram realizadas em equipamento Vista MPX simultâneo ICP-OES (Agilent, Australia). A validação do método foi realizado segundo os critérios descritos na RDC n° 899: Guia para validação de métodos analíticos e bioanalíticos de 29 de maio de 2003. De acordo com a Farmacopeia Americana (USP), as impurezas elementares com potencial toxicidade devem ser quantificados. Uma proposta de revisão USP 35 introduz a técnica de espectrometria de emissão atômica para a análise de elementos. Os resultados de validação das análises no ICP-OES indicam a necesidade de controle da limpeza e manutenção do equipamento, alterações do sample uptake delay e avaliação da robustez com as linhas do Mg. As curvas analíticas e faixas de concentracões analisadas foram lineares com r > 0,99. Os resultados de DPR foram abaixo de 5%. Todos os resultados dos parâmetros avaliados estão de acordo com os estabelecidos pela ANVISA. / Radiopharmaceuticals are pharmaceutical preparations containing radionuclide used in nuclear medicine. The aim of this work was to study the concentrations of chemical elements, especially metals, in samples of radiopharmaceuticals ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDA-TEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-FLÚOR-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. The analyses were carried out simultaneously in an ICP-OES Vista MPX (Agilent). The method validation was performed according to the criteria defined in RDC No. 899 : Guide for validation of analytical and bioanalytical methods for May 29, 2003 of the ANVISA. According to the U.S. Pharmacopeia (USP), the elemental impurities with potential toxicity must be quantified. A proposed revision to USP 35 introduces the technique of atomic emission spectrometry for the analysis of elements. The validation results of the ICP- OES analyzes indicated the necessary to control the cleaning and maintenance of equipment, changes in sample uptake delay and robustness evaluation with the lines of Mg. The analytical curves and concentration ranges analyzed were linear with r > 0.99. The results of DPR were below 5%. All the parameters were below the established by ANVISA .
124

Otimização e validação de metodologia analítica para determinação de metais e semimetais em efluentes líquidos por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Optimization and validation of analytical methodology for determination of metals and semimetals in wastewater by inductively coupled plasma optical emission spectrometry (ICP-OES)

Marques, Joyce Rodrigues 24 November 2015 (has links)
Além da Resolução CONAMA 430/11 definir limites para o lançamento de efluentes, também define que os laboratórios que realizam análises ambientais devem ser acreditados pelo INMETRO e também devem ter sistema de controle de qualidade implantado. Para o atendimento destes requisitos legais, o presente trabalho visa otimizar, validar e implantar a metodologia analítica desenvolvida e aplicada no Centro de Química e Meio Ambiente (CQMA) do Instituto de Pesquisas Energéticas e Nucleares (IPEN/ CNEN SP) para a quantificação dos elementos cádmio, chumbo, cobre, prata, crômio, zinco, estanho, níquel, ferro, bário, manganês e boro em amostras de efluentes líquidos por Espectrometria de Emissão Óptica com Plasma Acoplado Indutivamente (ICP-OES). Esta metodologia é utilizada para a determinação de metais e semimetais em amostras coletadas no Programa de Monitoramento Ambiental PMA-Q do IPEN. Todo o processo de validação desta dissertação foi baseado no guia Orientativo do INMETRO DOQ-CGCRE-008 - Orientação sobre Validação de Métodos Analíticos. No estudo de seletividade verificou-se que a matriz não interfere nas curvas analíticas do método em estudo; a faixa de trabalho foi determinada com base nos valores máximos permitidos (VMP) pelas legislações ambientais vigentes (Resolução CONAMA 430/11, DE 8.468/76 e DE 15.425/80) e no histórico de dados do PMA-Q e todas as curvas analíticas apresentam comportamento linear na faixa de trabalho abrangida pelo método; os limites de detecção e quantificação do método atendem aos limites definidos pelas legislações ambientais vigentes e à precisão e exatidão necessárias; a precisão e exatidão apresentaram resultados satisfatórios para a finalidade do método analítico; além do método demonstrar-se robusto, embora seja necessário que o analista se atente à variação de alguns fatores no momento da realização das análises. Também foi possível realizar a estimativa de incerteza do método de modo que fosse alcançado nível de confiança de 95% dos resultados, foram levadas em consideração todas as etapas de preparo e análise das amostras e foi possível obter incerteza global entre 4,6% e 12,23%. Através dos resultados obtidos nos testes estatísticos e pela avaliação do analista foi possível verificar que o método desenvolvido e aplicado no CQMA é adequado para o fim pretendido. / Beyond define limits to wastewater release, CONAMA Resolution n° 430/11 also define that laboratories, which perform environmental analysis, have to be accredited by INMETRO and must have quality control system deployed. In order to meet this legal requirements, this work aims to optimize, validate and deploy the analytical methodology developed and applied at the Centre of Environmental Science and Technology (CQMA) at Nuclear and Energy Research Institute (IPEN/ CNEN - SP), to the determination of the elements: cadmium, lead, copper, chromium, zinc, tin, nickel, iron, barium, manganese and boron in wastewater samples by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES). This methodology is used to the determination of metals and semimetals in samples collected in the IPENs Environmental Monitoring Program PMA-Q. The entire process of validation in this dissertation relied on INMETRO guide DOQ-CGCRE- 008 Guidance for Validation of Analytical Methods. In the selectivity test it was possible to verify that the matrix cause no interferences in the calibration curves of the studied method; the working range determined was based on the Maximum Allowed Values (VMP) defined by the current environmental legislations (CONAMA Resolution 430/11, State Decree 8.468/76 and State Decree 15.425/80) and in the historical data from PMA-Q and all calibration curves presented linear behavior; the detection and quantification limits of this method also attend to the requirements of the current environmental legislation and to the required precision and accuracy; the precision and accuracy presented suitable results for the methodology objective; additionally, the analytical method presented satisfactory robustness, although the responsible for the test have to have attention to any instabilities in some factors. The measurement uncertainty was estimated as well, in order to obtain results with 95% of confidence, all steps of preparation and analysis of the samples were considered and was possible to reach global uncertainty between 4,6% and 12,23%. Through the results obtained in the statistics tests and the analyst evaluation, was possible to conclude that the analytical methodology developed at CQMA is adequate to the intended purpose.
125

Desenvolvimento e validação de metodologia para determinação de metais em amostras de água por espectrometria de emissão óptica com plasma de argônio (ICP-OES) / Development and validation of methodology for determination of metals in water samples by optical emission with argon plasma spectrometry (ICP-OES)

Faustino, Mainara Generoso 05 November 2015 (has links)
Para atender a legislação ambiental do Conselho Nacional do Meio Ambiente (CONAMA), a Resolução CONAMA 357/2005, é necessário desenvolver metodologias que se aplicam na medição analítica de forma correta e para um controle de qualidade é necessário a aplicação da validação de metodologia. Para atender as exigências legais, o presente trabalho desenvolveu uma metodologia para a identificação de 12 elementos metálicos, tais como: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na e Ni em águas, avaliando 14 pontos, sendo eles GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distribuídos pela Represa Guarapiranga, situada no Estado de São Paulo, aplicando a metodologia validade, realizada com base no guia do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO), Orientação sobre Validação de Métodos Analíticos - DOQ-CGCE-008. Foram avaliados os parâmetros: seletividade, faixa de trabalho/linearidade, limites de detecção e quantificação, tendência/recuperação, precisão, robustez e incerteza de medição. Foi utilizado a técnica de espectrometria de Emissão Óptica com Plasma de Argônio (ICP-OES). O teste de seletividade comprovou que a matriz não interfere nas curvas analíticas elaborada; a faixa de trabalho apresentou um comportamento linear, para as amostras com e sem a matriz de interesse, com um coeficiente de correlação (r), entre 0,9965 a 1,0; os limites de detecção e quantificação do método atendem aos valores máximos permitidos pela Resolução CONAMA 357/2005; com os testes de repetitividade e de recuperação o método demonstrou ser preciso e exato, além de robusto. Posteriormente foi estimado uma incerteza de medição do método. A incerteza expandida estimada variou entre 3 e 18% da concentração encontrada. A validação da metodologia permitiu a sua aplicação para a avaliação da distribuição dos 12 elementos, nas águas da represa Guarapiranga. Foram observados valores altos para Ca, Na e K, em todos os pontos de coletas analisados, evidenciando que são os elementos que fazem parte da característica geológica da área. Os elementos Fe e Al obtiveram valores acima da legislação nos pontos da Represa (G000-01, G000-02 e G000-03). Com os testes dos parâmetros para a validação, com os cálculos estatísticos aplicados, foi possível desenvolver e aplicar uma metodologia adequada para o uso pretendido. / To attend the environmental legislation of the National Environmental Council (CONAMA) CONAMAs Resolution 357/2005, it is necessary to develop methodologies that apply the analytical measurement correctly and to a quality control application of the methodology validation is required. To attend legal requirements, this study developed a methodology for identifying 12 metals, such as: Al, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na and Ni in water in 14 points, being them GU000-01 (23°46\'49.6\"S-46°47\'22\"0W), GU000-02 (23°45\'29.5\"S-46°46\'18.7\"W), GU000-03 (23°44\'52.2\"S-46°46\'13.6\"W), GU106-04 (23°44\'44.6\"S-46°45\'25.8\"W), GU000-05 (23°44\'57.5\"S-46°45\'24.2\"W), GU107-06 (23°45\'01.2\"S-46°43\'61.5\"W), GU108-07 (23°43\'64.7\"S-46°43\'42.3\"W), GU000-08 (23°42\'96.9\"S-46°43\'61.2\"W), GU109-09 (23°43\'04.6\"S-46°43\'34.0\"W), GU105-10 (23°42\'89.9\"S-46°44\'68.7\"W), GU108-11 (23°42\'53.4\"S-46°43\'44.9\"W), GU103-12 (23°41\'88.5\"S-46°44\'67.3\"W), GU102-13 (23°41\'58.0\"S-46°43\'57.3\"W), GU000-14 (23°40\'78.2\"S-46°43\'55.0\"W), distributed by Guarapiranga dam, in the State of São Paulo, applying the methodology of validation based on the National Institute of Metrology, Quality and Technology (INMETRO) guide, \"Guidance on Analytical Methods Validation - DOQCGCE- 008\". The parameters analyzed were: selectivity, working range/linearity, limits of detection and quantification, tendency/recovery, accuracy, robustness and measurement uncertainty. Was used the optical emission with argon plasma spectrometry (ICP-OES) technique. The selectivity test proved that the matrix does not interfere with elaborate analytical curves; the elaborate working range obtained demonstrate a linear behavior for samples with and without the matrix of interest, with a coefficient of correlation (r) between 0,9965 and 1,0; limits of detection and quantification of this method meet the maximum values allowed by CONAMA Resolution 357/2005; with repeatability of tests and recovery method proved to be precise and accurate, and robust. It was subsequently estimated uncertainty of measurement method. The estimated expanded uncertainty varied between 3 and 18% of the concentration found. The validation of the methodology allowed the application for the evaluation of the distribution of 12 elements in Guarapiranga dam waters. Were observed high values for Ca, Na and K, at every point analyzed collections, showing, which are, the elements that are part of the geological characteristic of the area. The iron and aluminum elements obtained values above the law in points Dam (G000-01, G000-02 and G000-03). With the parameters for the validation tests, with the statistical calculations applied, it was possible to develop and apply a methodology appropriate for the intended use.
126

Confiabilidade metrológica da determinação de elementos tóxicos e essenciais em leite bovino de raças exploradas no Brasil / Metrological reliability in determining toxic and essential elements in bovine milk of breeds exploited in Brazil

Santos, Luís Gustavo Cofani dos 18 September 2009 (has links)
O leite é um alimento completo. Contém micronutrientes, aminoácidos, ácidos graxos em proporções adequadas à nutrição humana. Sua composição pode ser simplificadamente dividida em água, lipídios, glicídios, proteínas e sais minerais. Todavia, a composição do leite não é absoluta. Fatores como raça, sistema de produção, alimentação e clima podem influenciar a qualidade do produto final. Os reflexos da globalização na agropecuária leiteira brasileira resultaram na implantação da Rede Brasileira de Laboratórios Centralizados da Qualidade de Leite (RBQL). A Instrução Normativa nº 51 (IN51), que faz parte do Programa Nacional de Melhoria da Qualidade do Leite (PNMQL), aprovou os regulamentos técnicos de produção, identidade e qualidade do leite tipo A, do leite tipo B, do leite tipo C, do leite pasteurizado e do leite cru refrigerado e o regulamento técnico da coleta de leite cru refrigerado e seu transporte. Cabe à indústria leiteira brasileira, cujo leite é predominantemente oriundo das raças Holandesa, Gir, Girolanda, Jersey, Pardo Suíço e Guzerá, garantir a qualidade do produto comercializado. O desenvolvimento de um sistema de medição confiável é primordial no campo industrial, científico e comercial. Assim sendo, a proposta desse trabalho foi avaliar quimicamente marcas de leite comercial UHT bovino, com diferentes quantidades de gordura e de diferentes unidades federativas do Brasil comprados no comércio da cidade de Piracicaba SP e comparar os valores determinados com os reportados pelos fabricantes na tabela de \"Informações Nutricionais\" nas embalagens, além de investigar a potencialidade da INAA na quantificação química da matriz alimentar em questão. Outro objetivo desse trabalho foi comparar quimicamente o leite oriundo de tanques de resfriamento do estado de Minas Gerais com tanques de resfriamento do estado do Rio Grande do Sul e comparar quimicamente o leite amostrado diretamente de animais de quatro propriedades do estado de São Paulo, fazendo inferências aos limites estabelecidos pela IN51, as legislações vigentes nacional e internacionalmente. Realizou-se também análise exploratória de algumas fontes de nutrientes na alimentação de gado bovino. Com os resultados, observou-se que a preparação das amostras e os procedimentos para a INAA foram empregados com sucesso para a determinação de Br, Ca, Co, Cs, Fe, K, Na, Rb e Zn. Em relação ao comparativo dos valores determinados com os valores declarados pelos fabricantes, Ca apresentou uma tendência dos valores medidos serem menores que os informados, diferentemente do ocorrido com o Na. Dos 16 elementos químicos quantificados pela INAA e ICP-MS, 10 apresentaram diferenças significativas (p < 0,01) entre as propriedades rurais do estado de Minas Gerais e do estado do Rio Grande do Sul. Dos elementos químicos que foram quantificados pela INAA, Br, Cs, K e Rb já foram mencionados em trabalhos desenvolvidos no Laboratório de Radioisótopos como importantes para a discriminação de sistema de produção de diversas culturas. Para o estudo do leite oriundo dos animais, os valores médios determinados para os parâmetros da qualidade, atendiam os limites estabelecidos pela IN51. Para os 16 elementos químicos determinados pela INAA e ICP-MS, Co e Mn foram os únicos em que não se verificaram diferenças significativas (p < 0,05) entre as quatro propriedades pelo teste das comparações múltiplas de Tukey. Pela análise de agrupamento, constatou-se que a raça é primordial para a separação dos grupos, entretanto, o sistema de produção também deve ser levado em consideração. Em relação aos limites máximos de tolerância (LMT) estabelecidos pela legislação brasileira e que possuem valores específicos para leite, verificou-se que As não excedeu os limites máximos estabelecidos, contudo, atenção deve ser dada aos elementos químicos Cr e Se por possuírem valores médios superiores aos LMT. Através dos resultados das frações de massa de volumosos e concentrados, destinados à alimentação de gado bovino, foi possível diferenciar a matriz da fonte de nutriente, bem como a origem / Milk is a complete food. It contains micronutrients, aminoacids, and fatty acids in adequate amounts for human intake. In a simple way, its composition can be divided into water, lipids, lactose, proteins and mineral salts. The composition of milk, however, is not an absolute one. Features such as breed, production system, nourishment and climate can affect the final product quality. The reflex of globalization on the Brazilian dairy husbandry resulted in the creation of the Brazilian Network of Milk Quality Central Laboratories (Rede Brasileira de Laboratórios Centralizados de Qualidade de Leite - RBQL). The Normative Instruction 51 (IN51), a constituent part of the National Milk Quality Improvement Program (PNMQL) has approved the technical regulations of production, identity and quality of type-A milk, type-B milk, type-C milk, pasteurized milk, and refrigerated raw milk as well as the technical regulation for refrigerated raw milk collecting and transportation. The Brazilian dairy industry, with milk mostly deriving from breeds Holandesa, Gir, Girolanda, Jersey, Pardo Suiço and Guzera, is in charge of insuring the quality of the commercialized product. Developing a reliable measuring system is essential in the industrial, scientific and commercial fields. Thus, the aim of this work is to chemically evaluate the brands of commercial UHT bovine milk with different amounts of fat and from different states of Brazil, purchased in the city of Piracicaba, state of São Paulo, and compare the established values with those informed by the manufacturers in the \"Nutritional Facts\" table in the packages labels, in addition to investigating the INAA potentiality in the chemical quantification of the respective feeding matrix. Another goal was to chemically compare the milk deriving from cooling tanks in the state of Minas Gerais and those from cooling tanks in the state of São Paulo, thus inferring on the limits established by the IN51, the national and international legislations in force. Also an exploratory analysis of a few nutrient sources of bovine cattle feeding was observed. The results indicated that the sample preparation and INAA procedures were successfully employed to determine Br, Ca, Co, Cs, Fe, K, Na, Rb and Zn. As to the comparison between the established values and those stated by the manufacturers, the Ca values tended to be lower than the informed ones, unlike what happened to Na. Out of 16 chemical elements quantified by INAA and ICP-MS, 10 showed significant differences (p < 0.01) between the rural properties in the state of Minas Gerais and those in the state of Rio Grande do Sul. Out of the chemical elements quantified by INAA, Br, Cs, K and Rb have already been pointed in works developed at the Laboratory of Radioisotopes as important to discriminate the production system of several crops. In the study of animal-derived milk, the mean values determined for the quality parameters met the limits established by the IN51. For the 16 chemical elements determined by INAA and ICP-MS, Co and Mn were the only ones showing no significant differences (p < 0.05) among all four properties by the Tukey multiple comparison test. Through the cluster analysis the breed was verified to be essential to the separation of groups, however, the production system is also to be taken into account. As to the maximum tolerance limits (MTL) established by the Brazilian legislation and having specific values for milk, the As did not exceed the maximum limits established, yet, attention must be paid to Cr and Se since their mean values are beyond the MTL. The mass fraction results determined in roughages and concentrates for bovine cattle feeding made possible the distinction of the nutrient source matrix and their origin
127

Elementos traço em soro sanguíneo medidos pelos métodos PIXE e ICP-MS / Trace elements in serum measured by PIXE and ICP-MS

Suene Bernardes dos Santos 02 May 2007 (has links)
O principal objetivo deste trabalho foi desenvolver uma metodologia de análise de soro sanguíneo utilizando os métodos Proton Induced X-ray Emission (PIXE) e Inductively Coupled Plasma Mass Spectrometry (ICP-MS). O PIXE é um método de análise multielementar baseado na detecção dos raios-X característicos emitidos pelas amostras, quando bombardeadas com feixes de íons (H+, He+, ...) com energia da ordem de alguns MeV. Já o ICP-MS é um espectrômetro de massa que analisa componentes de amostras ionizadas, separados de acordo com suas razões massa carga (m/z). Para a realização deste estudo, as amostras de sangue dos voluntários (30 jovens com idade entre 18 e 25 anos) foram coletadas no Hospital Universitário da USP utilizando tubos de vidro da BD VacutainerTM sem aditivos (Processo do Comitê de Ética: HU-615/05). O soro foi obtido pela centrifugação dos tubos a 3000 rpm. As amostras foram pipetadas sobre Nuclepore (10?m de espessura) e secas a temperatura ambiente, para o método PIXE, e diluídas de 1:10, para as análises com ICP-MS. A acurácia dos resultados foi verificada analisando materiais de referências de soro do National Institute of Public Health - Québec (ICP-03B-02 e ICP-02-S-05). A análise dos padrões apresentou 78% dos dados entre ±1?, 14% entre ±2? e 4% além de ±3?. Este estudo de elementos traço em soro humano revelou um total de 22 elementos: Be, Al, P, S, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Br, Mo, Cd, Sn, Tl e Pb, com concentrações entre 9 ng/l e 6 g/l, o que compreende 9 ordens de grandeza, e também permitiu o estudo das funções de distribuição de probabilidades dos elementos. As técnicas utilizadas foram eficientes e complementares na realização deste trabalho. Os resultados das concentrações elementares medidas neste trabalho concordaram com os valores da literatura. / The main objective of this work was to develop a methodology for the analysis of blood serum by Proton Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). PIXE is a multi elementary spectrometric method that relies on the detection of characteristics X-rays emitted by a sample bombarded with an energetic (~MeV) ion beam (H+, He+, ...). With the ICP-MS one measures the elementary components in an ionised sample, separated according to their mass to charge ratio (m/z). For this study, the blood samples were collected from 30 young healthy adult volunteers with age between 18 and 25 years, in the University Hospital using additiveless BD VacutainerTM tubes (Authorisation agreement HU-615/05). Blood serum was obtained by centrifugation of the tubes at 3000 rpm. For PIXE analysis, the serum samples were pipetted on Nuclepore film (10?m thick) and dried at room temperature. For the ICP-MS analysis, the serum samples were diluted 1:10. Accuracy of both methods was obtained analysing serum reference materials supplied by the National Institute of Public Health - Québec (ICP-03B-02 and ICP-02-S-05). The analysis of the reference materials presented results for the elementary concentrations within ±1? for 78% of the data, 14% of the data lied within ±1? and ±2?, and 4% above ±3?. The analysis of trace elements in human blood serum by PIXE and ICP-MS revealed a total of 22 elements, ranging over 9 orders of magnitude: Be, Al, P, S, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Se, Br, Mo, Cd, Sn, Tl e Pb, with concentrations between 9 ng/l and 6 g/l. The PIXE and ICP-MS techniques were efficient and complimentary for the accomplishment of this work. The elementary concentrations measured in this work agreed with overall data in literature.
128

"Estudo de assinaturas químicas em cerâmica da tradição Tupiguarani da região central do estado do Rio Grande do Sul, Brasil" / CHEMICAL SIGNATURE STUDY OF TUPIGUARANI CERAMIC TRADITION FROM CENTRAL REGION OF THE RIO GRANDE DO SUL STATE, BRAZIL.

Bona, Irene Akemy Tomiyoshi 23 June 2006 (has links)
O modelo aplicado neste trabalho está baseado em resultados experimentais usando dados de composição química dos fragmentos cerâmicos, aplicados à teste não paramétrico de Spearmann, análise de componente principal e análise discrimante. As amostras são fragmentos cerâmicos da Tradição Tupiguarani de sítios e amostras de solos da região central do Estado do Rio Grande do Sul. Os elementos químicos, Al, Ba, Ca, Cr, Fe, K Mn, Pb, Rb, S, Si, Sr, Ti, V e Zn foram determinados usando-se as técnicas de fluorescência de raios X por dispersão de energia (EDXFR). Os elementos, Ce, Cu, Gd, La, Nd, Pr, Sm, Th e Y por espectrometria de massas de alta resolução com fonte de plasma acoplado indutivamente (HR-ICP-MS). A partir destes resultados, foram propostas relações entre as características da cerâmica, os sítios estudados e a dispersão dos fragmentos nos diversos sítios. Observaram-se indícios de assinatura química da função da vasilha de ir ou não ao fogo. A maior dispersão é de vasilhas pequenas com tratamento de superfície não corrugada. Verificaram-se assinaturas químicas para o entorno dos rios Ijuí, Ibicuí-Vacacaí Mirim e Jacuí. / In this work a model based on experimental results using chemical composition data of the pottery sherds applied to Spearmann’s no parametric test, principal component analysis and discriminant analysis, was applied. The samples are soils and Tupiguarani Tradition pottery sherd from the central area of the Rio Grande do Sul State. The chemical elements , Al, Ba, Ca, Cr, Fe, K Mn, Pb, Rb, S, Si, Sr, Ti, V and Zn were determined by energy dispersive X-ray fluorescence (EDXFR) while Ce, Cu, Gd, La, Nd, Pr, Sm, Th and Y by high-resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) techniques. Relationships among the pottery characteristics, studied sites and sherd dispersion in the several sites were proposed. Indications of chemical signature of the small pottery with function to go or not to the fire were observed. The largest dispersion is of small pottery with surface treatment no corrugated. The potteries chemical fingerprints from Ijuí River, Ibicuí-Vacacaí Mirim River and Jacuí River were verified.
129

Apport de la spectrométrie de masse à la détermination de l'origine géographique et la caractérisation du sélénoproteome dans le riz / Mass spectrometry approaches to the determination of geographical origin and selenoproteomics of rice

Cheajesadagul, Pracha 16 December 2013 (has links)
La thèse a soulevé deux défis dans l’analyse des métaux dans le riz : (i) un dosage multiélémentaire dans le but de la classification du riz selon l’origine géographique, et (ii) la spéciation du sélénium, élément essentiel dans la nutrition, dans le but de l’identification des cibles moléculaires de son assimilation et stockage. Une méthode d’analyse multiélémentaire par l’ICP MS combinée avec des techniques chimiométriques a été proposée comme outil pour la discrimination des riz selon leurs origines géographiques. Les concentrations des 21 éléments ont été analysées par le diagramme en radar, l’analyse en composantes principales, et l’analyse discriminante linéaire. Le riz thaï (riz jasmin) a pu être discriminé des riz étrangers. De plus, l’analyse discriminante a permis de de différencier les riz produits dans les différentes régions de Thaïlande. L’approche de protéomique assistée par l’ICP MS a permis l’identification d’une douzaine de protéines accumulant préférentiellement le sélénium sous forme de sélénomethionine et de sélénocystéine (en proportion 2:1). / The PhD work is focused on two major analytical chemistry challenges concerning rice characterization: (i) the geographical origin classification of rice based on multi-element fingerprinting and (ii) speciation of selenium with the goal of the identification of molecular target of it assimilation and storage in rice. The methods based on the multi-element fingerprinting by inductively coupled plasma mass spectrometry (ICP-MS) in combination with multivariate statistical techniques were developed and validated as tools for authentication of rice. Twenty-one key variables were assessed by a radar plot technique and multivariate data analysis, including principal component analysis (PCA) and discriminant analysis (DA) enabling classification according to geographical origin. Thai jasmine rice could be clearly differentiated from foreign rice samples. In addition, the DA could be used to classify Thai jasmine rice obtained from different regions in Thailand. In the second part of the project, an analytical ICP-MS-assisted proteomic method was developed for the identification of Se-containing proteins in rice. Selenium was found to be present as both selenomethionine (SeMet) and selenocysteine (SeCys) in a dozen of rice proteins with the Se/S substitution ratio two times higher for SeMet than that for SeCys.
130

An?lise de sedimento de fundo: uma amostragem representativa do estu?rio Potengi/RN

Dantas, A?cia Seleide 02 September 2009 (has links)
Made available in DSpace on 2014-12-17T15:41:47Z (GMT). No. of bitstreams: 1 AeciaSD.pdf: 4171408 bytes, checksum: b9c9bc4aed8af7d73b5b0b74a8b69ab1 (MD5) Previous issue date: 2009-09-02 / The aim of this study is to quantify the presence of major and minor elements in the sediments of estuary Potengi. Four georeferenced sampling points were used in the study, at which sediment samples were collected in the channel of the river and on the right and left banks. In addition, dissolved oxygen, salinity and water conductivity were taken in situ at the time of sample collection. The percentage of organic matter, determined by gravimetry, and granulometric analysis of the sediment samples were conducted in the laboratory. To quantify the major and minor elements a prior test to open the sample was conducted with standard NIST 1646? estuarine sediment to choose the best methodology to be adopted. The sediment samples were dissolved in microwaves with nitric acid and chloridric acid, according to methodology proposed by US EPA 3051?. Quantitative analyses of the elements Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb and Zn were conducted by inductively coupled plasma optical emission spectrometry (ICPOES). The results showed that the partial concentrations of the elements analyzed are below average worldwide shale levels, the standard described by Turekian and Wedepohl (1961) / Esse trabalho objetiva avaliar, por meio da quantifica??o, a presen?a dos elementos maiores e menores nos sedimentos do estu?rio Potengi. Para o estudo, foram definidos quatro pontos de amostragem georeferenciados, onde em cada um deles foram coletadas amostras de sedimento na calha do rio e nas margens esquerda e direita. Al?m disso, foram realizadas medidas de pH, oxig?nio dissolvido, salinidade e condutividade da ?gua in situ no momento da coleta. Em laborat?rio foram feitas determina??es da porcentagem de mat?ria org?nica por Gravimetria e an?lise granulom?trica nas amostras de sedimento. Para quantifica??o dos elementos maiores e menores foi realizado um teste pr?vio para abertura da amostra com um padr?o de sedimento estuarino NIST 1646a para escolha da melhor metodologia a ser adotada. As amostras de sedimento foram digeridas em microondas com ?cido n?trico e ?cido lor?drico segundo metodologia proposta pela US EPA 3051A. As an?lises quantitativas dos elementos Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb e Zn foram realizadas por espectrometria de emiss?o ?tica com plasma acoplado indutivamente (ICP-OES). Atrav?s destas observou-se que as concentra??es parciais dos elementos analisados est?o abaixo do folhelho padr?o tomado como m?dia mundial descritas por Turekian e Wedepohl (1961)

Page generated in 0.0353 seconds