Spelling suggestions: "subject:"imprint.""
91 |
Desenvolvimento de polímeros de impressão molecular para microextração em ponteiras de bisfenol A em amostras de urina e análise por GC-MS / Development of molecularly imprinted polymer for disposable pipette extraction of bisphenol A in biological samples and analysis by GC-MSBrigante, Tamires Amabile Valim 26 October 2015 (has links)
O Bisfenol A (BPA, acrônimo da língua inglesa - bisphenol A) é uma substância utilizada na fabricação de embalagens alimentícias e resinas odontológicas. Sua toxicidade deve-se ao fato de que, como disruptor endócrino, afeta o sistema reprodutor, cardiovascular, neuro-endócrino e pode apresentar potencial carcinogênico. Em métodos bioanalíticos, o preparo da amostra tem sido requerido para aumentar a seletividade e sensibilidade analítica, através da remoção dos interferentes da amostra biológica e concentração dos analitos, quase sempre presentes em níveis de traços. A microextração em ponteiras (DPX, acrônimo das iniciais em língua inglesa - Disposable Pipette Extraction), baseada no equilíbrio de sorção do soluto com a fase extratora, consiste em uma ponteira padrão de micropipeta modificada, na qual o sorvente está contido livremente entre dois filtros, permitindo rápida extração do analito em diferentes matrizes complexas. Os polímeros de impressão molecular (MIP acrônimo das iniciais em língua inglesa - Molecularly Imprinted Polymer) consistem em uma rede polimérica tridimensional que possui cavidades seletivas para o reconhecimento molecular do analito ou de substâncias de estrutura análoga. Essa rede polimérica é sintetizada ao redor da substância molde (analito), e a cavidade seletiva é formada após a remoção do molde. As vantagens do processo sol-gel para a síntese do MIP são o controle do tamanho e forma das partículas, ajuste da hidrofobicidade e alta estabilidade térmica. No presente trabalho, o MIP foi sintetizado e utilizado como sorvente para a técnica DPX para a determinação de bisfenol A em amostras de urina por cromatografia em fase gasosa acoplada à espectrometria de massas (GC-MS, acrônimo das iniciais em língua inglesa - Gas Chromatography coupled to Mass Spectrometry). O MIP foi sintetizado pela via sol-gel utilizando aminopropiltrietoxisilano (APTES) como mônomero funcional e tetraetil-orto-silicato (TEOS) como reagente de ligação cruzada. Como molde foram avaliados o BPA para o MIP, e o tetrabromobisfenol A (TBBPA) para o polímero molecularmente impresso com molécula análoga ao analito (DMIP, acrônimo das iniciais em língua inglesa - Dummy Molecularly Imprinted Polymer). Para avaliar a seletividade do MIP, o polímero não impresso (NIP, acrônimo das iniciais em língua inglesa - Non-imprinted Polymer) foi sintetizado seguindo o mesmo procedimento de síntese do MIP com exceção da adição da molécula molde. Apesar de a capacidade de sorção do MIP ser ligeiramente maior, o DMIP foi selecionado como sorvente para minimizar o efeito de memória. O DMIP foi caracterizado por microscopia eletrônica de varredura (MEV) e por espectroscopia vibracional na região do infravermelho por transformada de Fourier (FTIR, acrônico das inicias em língua inglesa - Fourier Transform Infrared). Os parâmetros da técnica DPX, tais como, o tempo de equilíbrio de sorção entre a amostra e o sorvente e condições de dessorção foram otimizadas por técnicas quimiométricas. A robustez do DMIP sintetizado via sol-gel foi comprovada pela reutilização deste sorvente por mais de 100 vezes, sem perda da eficiência da extração. O método desenvolvido DPX/GC-MS apresentou linearidade na faixa de 50 a 500 ng mL-1, precisão com CV (coeficientes de variação) entre 4 e 14% e de exatidão com valores de erro padrão relativo (EPR) de -13,6 a 12,3%. O método de referência utilizando a extração líquido-líquido e GC-MS (LLE/GC-MS), faixa de linearidade de 5 a 50 ng mL-1, foi desenvolvido e validado. Embora o método DPX/GC-MS inovador, quando comparado ao LLE/GC-MS, tenha apresentado maior limite de quantificação, apresentou as seguintes vantagens: simplicidade, rapidez e utilização de menores volumes de amostra e de solventes orgânicos na etapa do preparo da amostra / Bisphenol A (BPA) is widely used in food package and dental resins manufacturing. Its toxicity is due to its endocrine disruptor activity that affects the reproductive, cardiovascular, neurological system and may have carcinogenic potential. In bioanalytical methods the sample preparation has been required to increase the selectivity and analytical sensibility by removing the interfering from the biological matrix and concentration of the analytes that are in trace levels most of the times. The disposable pipette extraction (DPX) is based on sorption equilibrium of the analyte between the sample and the extraction phase. It consists in a pipette that contais the sorbent phase freely between two filters. Then, the extraction of the solute from the complex sample occurs quickly. Molecularly imprinted polymer is a tridimensional polimeric network that has selectivity cavities that can recognize an analyte or a substance with a similar structure. The polimeric network is synthesized around to a template molecule and after removing this template, a selective cavity is formed. The advantages of the sol-gel process for the synthesis of MIP are the control of the size and shape of the particles, hydrophobicity adjustment and high thermal stability. In the present study MIP was synthesized and used as sorbent to DPX method for determination of BPA in urine samples by gas chromatography coupled to mass spectrometry (GC-MS). Sol-gel methodoly was used to synthesize the polymers. Aminopropyltriethoxysilane (APTES) was used as a functional monomer and tetraethyl orthosilicate (TEOS) as crosslinking reagent. BPA and tetrabromobisphenol A (TBBPA) were evaluated as template to the synthesis of MIP and dummy molecularly imprinted polymer (DMIP) which is a molecularly imprinted polymer that uses a template structurally similar to the analyte. The non-imprinted polymer (NIP) was synthesized following the same procedure that MIP, except for the addition of template. It was made to verify the improvement of selectivity and sensibility of molecularly imprinted polymers. Although the sorption capacity of the MIP is slightly larger, DMIP has been selected as a sorbent in order to minimize the memory effect. The DMIP was characterized by Scanning Electron Microscopy (SEM) and Fourier Transform Infrared spectroscopy (FTIR). The parameters of DPX, such as time sorption equilibrium between the sample and the sorbent and desorption conditions were optimized by chemometrics. Robustness of DMIP sinthesized by sol-gel process was evidenciated for the reuse of DMIP for more than a 100 times. The developed method DPX/GC-MS showed linearity on the range from 50 to 500 ng ml-1, precision values with coefficient of variation (CV) betweeen 4 and 14% and accuracy with relative standard deviation values (RSD) from -13.6 to 12.3%. The reference method using liquid- liquid extraction and GC-MS (LLE/GC-MS) was developed and validated, showing linearity from 0.5 to 50 ng mL-1. Althout the innovative method DPX/GC-MS has showed limit of quantification larger than LLE/GC-MS, it presents the following advantages: simplicity, rapidy and utilization of smaller volumes of organic solvents on the sample preparation step
|
92 |
Estudo e fabricação de dispositivos inteligentes (línguas e narizes eletrônicos) visando à discriminação de contaminação em alimentos / Study and development of smart devices (electronic nose and tongues) aiming at discrimination of contamination in food samplesBueno, Lígia 05 April 2016 (has links)
A proposta da presente tese foi desenvolver dispositivos inteligentes (língua e nariz eletrônicos/ colorimétrico) de baixo custo para discriminar amostras de alimentos contaminados quimicamente e biologicamente. Um dispositivo \"optoeletrônico\" à base de membranas poliméricas coloridas com indicadores de pH foi utilizado para discriminar compostos voláteis emitidos por micro-organismos (aminas liberadas pelos processos de deterioração dos alimentos e que são produto da descarboxilação de aminoácidos em alimentos predominantemente proteicos). As aminas avaliadas nesse estudo foram: isobutilamina, isopentilamina e trietilamina. O limite de detecção de 5 ppm das aminas foi alcançado utilizando o dispositivo \"optoeletrônico\" e, esse sistema, também foi testado em amostras reais de carne contaminadas obtendo uma boa discriminação das amostras com e sem as aminas. Aminas biogênicas (cadaverina, tiramina e putrescina) também foram testadas obtendo uma separação pelo gráfico de escores. Em uma segunda etapa o dispositivo também foi avaliado para discriminar quatro espécies de bactérias (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis e Escherichia coli) incubadas a 37°C e 25°C. Em ambos os casos o dispositivo inteligente utilizou um smartphone para registrar as imagens que atuou como detector para extração dos dados de RGB das imagens. A partir dessas informações (valores de RGB), as ferramentas quimiométricas PCA (do inglês Principal Component Analysis, Análise de Componentes Principais) e HCA (do inglês Hierarchical Cluster Analysis, Análise de Agrupamentos Hierárquicos) foram utilizadas para discriminar as amostras e a k-NN (do inglês kth Nearest Neighbor, k- vizinhos mais próximos) para validar o método. Em uma terceira etapa, uma língua eletrônica voltamétrica foi fabricada para discriminar amostras de leite adulteradas com melamina, ureia e formaldeído contendo concentrações finais de 0,95; 4,16 e 10,0 mmol L-1, respectivamente. Essa língua voltamétrica foi composta por três eletrodos metálicos: platina, ouro e cobre e dados voltamétricos foram utilizados como dados de entrada para as ferramentas quimiométricas (PCA e HCA). Foram testados três tipos de leite (integral, desnatado e semidesnatado) de três diferentes marcas e todos eles puderam ser discriminados com sucesso. O trabalho também apresenta a utilização de MIPs (polímeros molecularmente impressos - do inglês, molecularly imprinted polymers) como alternativa para detecção e discriminação de alimentos contaminados fazendo uso da impressão (cavidades) de substâncias químicas contaminantes ou das proteínas específicas de cada micro-organismo presente no processo de deterioração dos alimentos / The present thesis aimed at development of low cost smart devices (electronic tongue and colorimetric nose) to discriminate chemically and biologically contamination in food samples. An \"optoelectronic\" plastic-based device with colored membranes contained pH indicator was used to discriminate volatile compounds released by microorganisms, due to the deterioration process of protein in food by the organisms. The amines evaluated in this study were: isobutylamine, isopentylamine and triethylamine, achieving a detection limit of 5 ppm. Such system was also tested in real meat samples contaminated with individual amines obtained a good discrimination of samples with and without studied compounds. Biogenic amines (cadaverine, tyramine and putrescine) were also tested and discriminated. In a second step, the device was also evaluated to discriminate four bacteria species (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis and Escherichia coli) incubated at 37 ° C and 25 ° C. In both cases, a smartphone was used as detector to extract RGB values of the samples. From extracted information (RGB values), the chemometric tools PCA (Principal Component Analysis) and HCA (Hierarchical Cluster Analysis) were used to discriminate samples and k-NN (kth Nearest Neighbor) was evaluated to validate the method. In a third stage, a voltammetric electronic tongue was developed to discriminate adulterated milk samples with melamine, urea and formaldehyde. This voltammetric electronic tongue was fabricated using three working electrodes: platinum, gold and copper and the voltammetric data was used as input data for chemometric tools (PCA and HCA). Three types of milk (whole, skimmed and semi-skimmed) from three different brands were tested and all of them could be successfully discriminated
|
93 |
Development of molecularly imprinted polymers for chemical sensors / Développement de polymères à empreintes moléculaires pour capteurs chimiquesLeibl, Nadja 07 December 2018 (has links)
Cette thèse propose une approche rationnelle pour le design de polymères à empreintes moléculaires (MIPs) pour la détection de nitro-explosifs. Les polymères à empreintes moléculaires qui miment la reconnaissance moléculaire biologique, ont l’avantage d’être stables dans des environnements sévères et peuvent adopter différentes formes physiques pour le couplage avec des transducteurs. Leur synthèse est basée sur la co-polymérisation de monomères fonctionnels et réticulants en présence de la molécule cible, ou comme dans cette thèse, d’un analogue ayant une structure proche de celle de la molécule cible. Cela conduit à la formation d’un réseau polymérique tridimensionnel rigide avec des sites de liaison complémentaires en taille, forme et position des groupes fonctionnels de la molécule cible ou de l’analogue. Pour identifier le meilleur monomère fonctionnel pour notre molécule cible, une approche rationnelle basée sur la modélisation moléculaire, la résonance magnétique nucléaire (RMN) et le titrage par calorimétrie isotherme (ITC) a été utilisée. Elle permet d’optimiser le mélange de pré-polymérisation pour identifier le monomère fonctionnel interagissant le plus fortement avec la molécule cible. Les résultats obtenus ont été confrontés à des études de liaison à partir de polymères synthétisés. La formulation polymérique ainsi conçue est intégrée aux surfaces du transducteur sous forme de nanoparticules, de films et de nanoparticules incorporés dans des films de polydopamine électropolymérisés. En plus des polymères traditionnels obtenus par polymérisation radicalaire classique sous forme de particules, des films de MIP à base de polydopamine électropolymérisés ont été étudiés en tant qu'approche alternative pour la détection électrochimique de nitro-explosifs. / This thesis proposes a rational design approach towards molecularly imprinted polymers (MIPs) for sensing nitro-explosives. Molecularly imprinted polymers are mimicking biological molecular recognition. They have the advantage to be stable in harsh environments and can be tailored into different physical forms for interfacing with transducers. Their synthesis is based on the co-polymerization of functional and cross-linking monomers in the presence of the target analyte or, as in this thesis, with a structural analogue leading to a rigid three-dimensional polymer network with binding sites complementary to the template in size, shape and position of the functional groups. The choice of the functional monomer was carried out with a rational design approach combining molecular modelling, nuclear magnetic resonance (NMR) and isothermal calorimetry (ITC) studies. This allows to optimize the pre-polymerization mixture in order to get strong complexation between the functional monomer and the template. The obtained results were confronted with binding studies performed on synthesized polymers. The thus designed polymer formulation was interfaced with transducer surfaces in form of nanoparticles, films and nanoparticles embedded into electro-polymerized polydopamine films. In addition to the traditional MIPs by free radical polymerization, molecularly imprinted in-situ electro-polymerized polydopamine films were investigated as an alternative approach for sensing nitro-explosives electrochemically.
|
94 |
Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymersJosé Eduardo dos Santos Clarindo 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
|
95 |
Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenacPereira, Abigail Vasconcelos 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 µmol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin®, Afopic® e Folifolim®, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac®, Medley® e Voltaren® e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 µmol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 µmol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin®, Afopic® and Folifolim®,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac®, Medley® and Voltaren® and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
|
96 |
Estudo e fabricação de dispositivos inteligentes (línguas e narizes eletrônicos) visando à discriminação de contaminação em alimentos / Study and development of smart devices (electronic nose and tongues) aiming at discrimination of contamination in food samplesLígia Bueno 05 April 2016 (has links)
A proposta da presente tese foi desenvolver dispositivos inteligentes (língua e nariz eletrônicos/ colorimétrico) de baixo custo para discriminar amostras de alimentos contaminados quimicamente e biologicamente. Um dispositivo \"optoeletrônico\" à base de membranas poliméricas coloridas com indicadores de pH foi utilizado para discriminar compostos voláteis emitidos por micro-organismos (aminas liberadas pelos processos de deterioração dos alimentos e que são produto da descarboxilação de aminoácidos em alimentos predominantemente proteicos). As aminas avaliadas nesse estudo foram: isobutilamina, isopentilamina e trietilamina. O limite de detecção de 5 ppm das aminas foi alcançado utilizando o dispositivo \"optoeletrônico\" e, esse sistema, também foi testado em amostras reais de carne contaminadas obtendo uma boa discriminação das amostras com e sem as aminas. Aminas biogênicas (cadaverina, tiramina e putrescina) também foram testadas obtendo uma separação pelo gráfico de escores. Em uma segunda etapa o dispositivo também foi avaliado para discriminar quatro espécies de bactérias (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis e Escherichia coli) incubadas a 37°C e 25°C. Em ambos os casos o dispositivo inteligente utilizou um smartphone para registrar as imagens que atuou como detector para extração dos dados de RGB das imagens. A partir dessas informações (valores de RGB), as ferramentas quimiométricas PCA (do inglês Principal Component Analysis, Análise de Componentes Principais) e HCA (do inglês Hierarchical Cluster Analysis, Análise de Agrupamentos Hierárquicos) foram utilizadas para discriminar as amostras e a k-NN (do inglês kth Nearest Neighbor, k- vizinhos mais próximos) para validar o método. Em uma terceira etapa, uma língua eletrônica voltamétrica foi fabricada para discriminar amostras de leite adulteradas com melamina, ureia e formaldeído contendo concentrações finais de 0,95; 4,16 e 10,0 mmol L-1, respectivamente. Essa língua voltamétrica foi composta por três eletrodos metálicos: platina, ouro e cobre e dados voltamétricos foram utilizados como dados de entrada para as ferramentas quimiométricas (PCA e HCA). Foram testados três tipos de leite (integral, desnatado e semidesnatado) de três diferentes marcas e todos eles puderam ser discriminados com sucesso. O trabalho também apresenta a utilização de MIPs (polímeros molecularmente impressos - do inglês, molecularly imprinted polymers) como alternativa para detecção e discriminação de alimentos contaminados fazendo uso da impressão (cavidades) de substâncias químicas contaminantes ou das proteínas específicas de cada micro-organismo presente no processo de deterioração dos alimentos / The present thesis aimed at development of low cost smart devices (electronic tongue and colorimetric nose) to discriminate chemically and biologically contamination in food samples. An \"optoelectronic\" plastic-based device with colored membranes contained pH indicator was used to discriminate volatile compounds released by microorganisms, due to the deterioration process of protein in food by the organisms. The amines evaluated in this study were: isobutylamine, isopentylamine and triethylamine, achieving a detection limit of 5 ppm. Such system was also tested in real meat samples contaminated with individual amines obtained a good discrimination of samples with and without studied compounds. Biogenic amines (cadaverine, tyramine and putrescine) were also tested and discriminated. In a second step, the device was also evaluated to discriminate four bacteria species (Klebsiella pneumoniae, Proteus vulgaris, Proteus mirabilis and Escherichia coli) incubated at 37 ° C and 25 ° C. In both cases, a smartphone was used as detector to extract RGB values of the samples. From extracted information (RGB values), the chemometric tools PCA (Principal Component Analysis) and HCA (Hierarchical Cluster Analysis) were used to discriminate samples and k-NN (kth Nearest Neighbor) was evaluated to validate the method. In a third stage, a voltammetric electronic tongue was developed to discriminate adulterated milk samples with melamine, urea and formaldehyde. This voltammetric electronic tongue was fabricated using three working electrodes: platinum, gold and copper and the voltammetric data was used as input data for chemometric tools (PCA and HCA). Three types of milk (whole, skimmed and semi-skimmed) from three different brands were tested and all of them could be successfully discriminated
|
97 |
Enzymatically initiated synthesis of biomimetic receptors based on molecularly imprinted polymers by free radical polymerization / Synthèse de récepteurs biomimétiques basés sur les polymères à empreintes moléculaires par polymérisation radicalaire libre initiée par catalyse enzymatiqueDaoud Attieh, Mira 01 April 2016 (has links)
Depuis de nombreuses années, l’utilisation d’enzyme pour la synthèse de polymères naturels ou synthétiques a largement été développée en tant que procédé alternatif plus vert et plus respectueux de l’environnement. En effet, comparée aux méthodes conventionnelles de synthèse, les enzymes offrent une sélectivité élevée, une capacité à réagir dans des conditions de réaction douces, ainsi que la possibilité de recyclage du biocatalyseur. D’autre part, les polymères à empreintes moléculaires (MIPs) sont des matériaux synthétiques avec des propriétés de reconnaissance moléculaire spécifique envers une molécule cible. Récemment, les MIPs ont été utilisés dans les applications environnementales et biomédicales de part leur propriétés de reconnaissance moléculaire, leur spécificité et sélectivité. Cependant, leur application reste limitée en raison de leur faible biocompatibilité et de la présence de résidu de polymérisation potentiellement nocif. Ce travail de thèse a pour objectif de proposer une méthode alternative pour la synthèse de MIPs basée sur le concept de chimie verte. La peroxydase de raifort (HRP) est utilisée pour initier la co-polymérisation en milieux aqueux de monomères fonctionnels méthacrylates et d’agents réticulants en catalysant la génération des radicaux libres. Différents hydrogels ont été synthétisés et caractérisés, en particulier une cytotoxicité plus faible a été obtenue comparée à celle des polymères synthétisés traditionnellement. La synthèse a été optimisée afin de pouvoir contrôler la taille des particules et le rendement de polymérisation. Des MIPs sous forme de nanoparticules ont été préparés en milieu aqueux pour plusieurs molécules de faible poids moléculaire ainsi que pour des protéines par polymérisation radicalaire libre initiée par HRP. L’effet de la méthode d’initiation a été évalué en comparant les propriétés de ces MIPs à ceux préparées par les méthodes traditionnellement. L’immobilisation de l’HRP a été aussi effectuée pour synthétiser des hydrogels et des MIPs. L’enzyme immobilisée a pu être réutilisée pour synthétiser des MIPs avec les mêmes performances en termes de morphologie, rendement, spécificité et sélectivité. Ces nouveaux matériaux offrent de nombreuses perspectives pour des applications environnementales et biomédicales. / Enzyme-catalyzed synthesis of natural and synthetic polymers has been developed since several decades, as an eco-friendly process. Compared to the conventional methods, enzymes offer high selectivity, ability to operate under mild conditions and to recycle the catalyst. On the other hand, molecularly imprinted polymers (MIPs) are synthetic materials with specific recognition properties for target molecules. They have recently attracted increasing attention in environmental and newly in biomedical applications for their specificity and selectivity. However, concerns about MIP toxicity for human and environment safety are of great importance. Herein, carrying forward the concept of green chemistry, an enzyme-mediated synthesis approach is described to prepare molecularly imprinted nanoparticles (MIP-NPs) in aqueous media. Horseradish peroxidase (HRP) is used to initiate the polymerization of methacrylate-based monomers and cross-linkers by catalyzing the generation of free radicals. Different hydrogels are synthesized and characterized. “Greener” hydrogels are obtained with lower cytotoxicity than that of polymers synthesized by traditional way. The hydrogels synthesis is optimized in order to control the particles sizes and polymerization yields. Moreover, water-compatible MIP nanoparticles for the recognition of different small molecules and proteins are prepared in aqueous media by HRP-initiated free radical polymerization and compared to MIPs prepared by the thermal or photopolymerization methods. HRP immobilization is also performed for hydrogels synthesis as well as MIP preparation. The reusability of immobilized enzyme is investigated for the preparation of several MIP batches with the same morphology, yield as well as good specificity and selectivity. We believe that this new synthesis method for MIPs will provide new opportunities to enlarge the use of molecular imprinting technology in biomedical and environmental applications.
|
98 |
Aplicação de eletrodos compósitos à base de grafite-poliuretana modificados com polímeros com impressão molecular, na determinação de ácido fólico e diclofenaco / Application of graphite-polyurethane composite electrodes modified with molecularly imprinted polymers in the determination of folic acid and diclofenacAbigail Vasconcelos Pereira 14 August 2015 (has links)
Neste trabalho foram preparados eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (EGPU-MIP) visando a determinação de ácido fólico (FA) e forma ácida do diclofenaco (DCF), os quais foram usados como moléculas molde. O objetivo principal era avaliar o desempenho dos MIPs em relação à seletividade e sensibilidade, além da inovação em relação ao uso dos compósitos como material de eletrodo, relativamente a esses analitos. No caso do FA, os MIP foram preparados com essa molécula, relativamente grande e contendo vários grupos funcionais, para avaliar o efeito dessas características no desempenho do sensor. Inicialmente foram feitos estudos exploratórios usando voltametria cíclica (CV), nos quais o FA apresentou pico irreversível de oxidação em +0,80 V (vs. SCE) e picos reversíveis de redução em -0,40 e -0,65 V (vs. SCE), com respectivos processos de oxidação em -0,33 e -0,49 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco usando voltametria de pulso diferencial (DPV), após otimizar parâmetros tais como composição de MIP no sensor de (2,5%, m/m), amplitude de pulso (a = 50 mV), velocidade de varredura (ν = 10 mV s-1) e meio eletrolítico (tampão acetato, pH = 4,5). Nesse procedimento, determinou-se uma mesma região linear de resposta entre 0,6 e 2,0 µmol L-1 para os dois picos de redução em -0,52 e -0,58 V (vs. SCE), com limites de detecção (LOD) de 0,17 e de 0,03 µmol L-1, respectivamente. O pico em -0,58 V mostrou-se mais sensível e foi escolhido para determinar o FA nas formulações farmacêuticas Folacin®, Afopic® e Folifolim®, com resultados concordantes com o método oficial baseado na Cromatografia líquida de alta eficiência (HPLC), em 95% de confiança, segundo o teste t-Student. O MIP-FA mostrou-se mais seletivo que o polímero sem impressão molecular (NIP-DCF) frente às interferências do metotrexato (MTX), porem o ácido ascórbico (AA), ácido úrico (UA) e dopamina (DA) mostraram interferências, em relação aos grupos funcionais presentes nessas espécies, com forte influência da rigidez estrutural e da mobilidade rotacional de tais grupos. Outro MIP foi sintetizado com impressão para DCF. A voltametria cíclica mostrou que o DCF apresenta pico irreversível de oxidação em + 0,83 V (vs. SCE), na primeira varredura e picos reversíveis de redução em +0,40 e +0,65 V (vs. SCE), a partir da segunda varredura, com respectivos processos de oxidação em +0,27 e +0,58 V (vs. SCE). Foi desenvolvido um procedimento analítico para determinação do fármaco em formulações comerciais, usando DPAdASV, após otimização dos parâmetros tais como composição de MIP no sensor (2,5%, m/m), tempo de acumulação (300 s) e potencial de pré-concentração (+0,2 V), a = 50 mV, ν = 10 mV s-1 em ácido perclórico pH condicional (pHcond) = 1,6, com uma região linear entre 0,010 e 0,20 nmol L-1 e LOD de 0,99 nmol L-1 para o pico anódico em +0,8 V (vs. SCE). O DCF foi determinado nas formulações farmacêuticas Biofenac®, Medley® e Voltaren® e em urina sintética. O MIP-DCF se mostrou relativamente seletivo ao sinal do DCF, mesmo na presença dos interferentes como ácido meclofenâmico (AMCFN) e ácido mefenâmico (AMFN), os quais apresentam grande semelhança estrutural e funcional em relação ao analito. Deve-se tomar cuidado ao estender o intervalo de potencial operacional para o GPU, neste meio de ácido perclórico, para evitar ativação de grupos funcionais do grafite e/ou da PU. / In this work methacrylate molecularly imprinted polymers (MIP) were prepared using folic acid (FA) as well as diclofenac (DCF) templates. These MIPs were used in the modification of graphite-polyurethane (GPU) composites in order to evaluate the performance of the resulting electrodes in the determination of the templates in pharmaceutical formulations and to estimate the sensitivity and selectivity of the resulting devices joined to the innovation of using the composites in such development regarding these analytes. In the case of FA, MIPs were prepared with this relatively large and containing multiple functional groups, to evaluate the effect of such characteristics in the performance of the sensor. First of all exploratory experiments were performed using cyclic votammetry (CV) in which the FA presented an irreversible oxidation peak at + 0.80 V (vs. SCE) and reversible reductions peaks at -0.40 and -0.65 V (vs. SCE) with respective oxidation at -0.33 and -0.49 V (vs. SCE). An analytical procedure was developed based on differential pulse voltammetry (DPV), after optimizing parameters such as MIP composition in the sensor (2.5%, m/m), pulse amplitude (a = 50 mV), scan rate (ν = 10 mV s-1) and supporting electrolyte (acetate, pH = 4.5). In such procedure was obtained a linear dynamic range from 0.6 to 2.0 µmol L-1 for both DPV reduction peaks at -0.52 and -0.58 V (vs. SCE), with limit of detection (LOD) of 0.17 and 0.03 µmol L-1, respectively. As the second on was more sensitive it was chosen for the determination of FA in the commercial pharmaceutical formulation Folacin®, Afopic® and Folifolim®,with results that agreed with those from the official HPLC procedure within 95% confidence level according to the t-Student test. The MIP-FA was more selective than the non-imprinted polymer (NIP-DCF) in relation to the interference of metotrexate (MTX), however ascorbic acid (AA), uric acid (UA) and dopamine (DA) revealed significant interferences regarding the functional groups present in these species, with strong influence from the structural rigidity of the molecule that plays an important role in the rotational mobility of these groups. Another MIP was synthesized with DCF as a template. Cyclic voltammetry demonstrated that the DCF presented a single irreversible oxidation peak at + 0.83 V (vs. SCE) in the first scan, and two reversible reduction peaks at +0.40 and +0.65 V (vs. SCE) with respective oxidation at +0.27 and +0.58 V (vs. SCE), from the second scan. A DPAdASV procedure was also developed for the determination of DCF in commercial formulations after optimizing some experimental parameters such as MIP composition in the sensor (2.5%, m/m), accumulation time (300 s) and potential (+0.2 V), a = 50 mV, v = 10 mV s-1 and supporting electrolyte (perchloric acid pHcond = 1.6). A linear dynamic range from 0.010 to 0.20 nmol L-1 and a LOD of 0.99 nmol L-1 were observed for the anodic peak at +0.8 V (vs. SCE). Then the DCF was determined in the commercial formulations Biofenac®, Medley® and Voltaren® and also in synthetic urine samples. The MIP-DCF sensor showed to be selective regarding the DCF signal even in the presence of meclophenamic acid (AMCFN) and mefenamic acid (AMFN), which present structural and functional similarity when compared with the analyte. Care must be taken when using the GPU in extreme potential windows in the perchloric acid medium, to avoid activation of functional groups in the polymer.
|
99 |
Determinação de tetraciclina utilizando eletrodos compósitos grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular / Determination of tetracycline using graphite-polyuretane composites electrodes modified with methacrylate molecularly imprinted polymersClarindo, José Eduardo dos Santos 27 September 2017 (has links)
Neste trabalho propôs-se desenvolver eletrodos compósitos à base de grafite-poliuretana modificados com polímeros metacrilatos com impressão molecular (MIP-TC), visando a determinação do antibiótico tetraciclina em formulações farmacêuticas e urina sintética. O trabalho também visou contribuir no desenvolvimento de um sensor com melhor desempenho no que diz respeito à sensibilidade e seletividade do eletrodo compósito modificado, na quantificação do analito/molécula molde em matrizes complexas. Técnicas eletroanalíticas, tais como voltametria cíclica (CV) e voltametria de pulso diferencial (DPV) foram utilizadas para avaliar a resposta em termos de sensibilidade e seletividade do eletrodo compósito na detecção da tetraciclina (TC), proposto neste trabalho. A otimização dos parâmetros, tais como composição do MIP (5,0 %, m/m), amplitude de pulso (50 mV), velocidade de varredura (10 mV s-1), tempo (300 s) e potencial de acumulação [(+ 0,7 V (vs. SCE)] e faixa granulométrica do MIP (150 a 250 μm), usando voltametria de redissolução anódica por pulso diferencial foi realizada para maximizar a determinação da tetraciclina em tampão fosfato 0,10 mol L -1 (pH 2,5), permitindo obter limites de detecção de 0,555 μmol L-1, 2,70 μmol L-1 e 4,71 μmol L-1, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, sem necessidade de renovação da superfície do eletrodo entre as sucessivas medidas. Regiões lineares entre 4,0 e 60,0 μmol L-1, 8,0 e 60,0 μmol L-1 e 20,0 e 100,0 μmol L-1/sup> foram observadas, respectivamente, para o EGPU-MIP-TC, EGPU e EGPU-NIP, para o pico anódico em + 0,9 V (vs. SCE). Os EGPU também foram testados quanto à seletividade frente à possíveis interferentes, sendo utilizados clortetraciclina (CTC) e oxitetraciclina (OTC) para os testes de interferência. Em todos os casos, a interferência do EGPU-MIP-TC foi menor do que a obtida com o EGPU-NIP, confirmando que o EGPU-MIP-TC foi mais efetivo na capacidade de reconhecer seletivamente o analito na presença dos interferentes CTC e OTC. Após as etapas de síntese dos MIP/NIP e confecção dos eletrodos, otimização dos parâmetros, avaliações e testes de sensibilidade e seletividade dos EGPU, os eletrodos foram submetidos à aplicação em duas amostras de medicamentos comerciais, TetraMed® 500 mg e genérico de cloridrato de tetraciclina 500 mg e uma amostra sintética de urina. Os resultados foram comparados ao método oficial por HPLC, apresentando 95 % de confiança, de acordo com o teste t-Student. / In this work, graphite-polyurethane composites electrodes were modified with methacrylate molecularly imprinted polymers (MIP-TC) in order to evaluate the electrodes in the determination of tetracycline (TC) antibiotic in pharmaceutical formulations as well as in biological fluid. The work aimed to contribute in development of a sensor with better performance about the sensitivity and selectivity of the composites electrodes modified in quantification of this analyte. Electroanalytical techniques such as cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used to evaluate the selectivity and sensitivity of the composite electrodes in the detection of tetracycline. The parameters optimization, such as MIP composition (5.0 %, m/m), pulse amplitude (50 mV), scan rate (10 mV s-1), accumulation time (300 s), accumulation potential [+ 0.7 V (vs. SCE)], and MIP granulometry (150 to 250 μm), using differential pulse anodic stripping voltammetry was done to maximize the determination of tetracycline in phosphate buffer 0.1 mol·L-1 pH 2.5 resulting in LOD of 0.555 μmol L-1, 2.70 μmol L-1 and 4.71 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP, without the need for surface renovation between the measures. A linear dynamic range from 4.0 to 60.0 μmol L-1, 8.0 to 60.0 μmol L-1 and 20.0 to 100.0 μmol L-1, respectively for the EGPU-MIP-TC, EGPU and EGPU-NIP was observed for the anodic peak at + 0.9 V (vs. SCE). The EGPU were also tested regarding the selectivity compared to possible interferents, such as chlortetracycline (CTC) and oxytetracycline (OTC) for the interference study. In all cases, the interference of EGPU-MIP-TC was lower than the one that was got with EGPU-NIP, confirming that the EGPU-MIP-TC was more selective than the non-imprinted polymer in the capacity of recognizing, selectively, the analyte in presence of CTC and OTC interferents. After the steps of synthesis of MIP/NIP and electrodes confection, parameters optimization, evaluation and EGPU sensitivity and selectivity studies, the electrodes were submitted to the application in two commercial drugs containing 500 mg of tetracycline cloridrate, TetraMed® and generic; and a synthetic urine sample. The results were compared to the official method by HPLC, presenting 95 % confidence according to the t-Student test.
|
100 |
Molecularly imprinted polymer sensor systems for environmental estrogenic endocrine disrupting chemicalsNtshongontshi, Nomaphelo January 2018 (has links)
Philosophiae Doctor - PhD (Chemistry) / There is growing concern on endocrine disrupting compounds (EDCs). The presence of drugs
in water supplies was first realized in Germany in the early 1990s when environmental
scientists discovered clofibric acid. Clofibric acid has the ability to lower cholesterol in ground
water below a water treatment plant. Endocrine disrupting compounds can be defined as those
chemicals with the ability to alter daily functioning of the endocrine system in living organisms.
There are numerous molecules that are regarded or referred to as EDCs such as but not limited
to organochlorinated pesticides, industrial chemicals, plastics and plasticizers, fuels, estrogens
and many other chemicals that are found in the environment or are in widespread use. 17?-
estradiol is the principal estrogen found in mammals during reproductive years. Estriol is
produced in large quantities during pregnancy. 17?-estradiol is the strongest, estriol the
weakest. Estriol is water soluble, estrone and estradiol are not. Although estrogen is produced
in women they are also at risk of over exposure to estrogen. Pesticides are extensively used
today in agricultural settings to prevent and control pests. Various pesticides, including banned
organochlorines (OCs) and modern non-persistent pesticides, have shown the ability to disrupt
thyroid activity, disturbing the homeostasis of the thyroid system. Because these EDCs have
adverse effects on health of both human and wildlife, it is imperative to develop viable costeffective
analytical methods for the detection of these EDCs in complicated samples and at
very low concentrations. Very high selectivity towards particular compounds is a very
important property for the suitability of a detection method. This is because these compounds
mostly coexist in complex matrices which makes the detection of a specific compound very
challenging. It is paramount to develop highly sensitive and selective methods for the detection
of these estrogens and phosphoric acid-based pesticides at trace levels. / 2021-08-31
|
Page generated in 0.0957 seconds