Quantitative ultrasound imaging during shear wave propagation for application related to breast cancer diagnosis

Alavi Dorcheh, Marzieh 04 1900 (has links)
Dans le contexte de la caractérisation des tissus mammaires, on peut se demander ce que l’examen d’un attribut en échographie quantitative (« quantitative ultrasound » - QUS) d’un milieu diffusant (tel un tissu biologique mou) pendant la propagation d’une onde de cisaillement ajoute à son pouvoir discriminant. Ce travail présente une étude du comportement variable temporel de trois paramètres statistiques (l’intensité moyenne, le paramètre de structure et le paramètre de regroupement des diffuseurs) d’un modèle général pour l’enveloppe écho de l’onde ultrasonore rétrodiffusée (c.-à-d., la K-distribution homodyne) sous la propagation des ondes de cisaillement. Des ondes de cisaillement transitoires ont été générés en utilisant la mèthode d’ imagerie de cisaillement supersonique ( «supersonic shear imaging » - SSI) dans trois fantômes in-vitro macroscopiquement homogènes imitant le sein avec des propriétés mécaniques différentes, et deux fantômes ex-vivo hétérogénes avec tumeurs de souris incluses dans un milieu environnant d’agargélatine. Une comparaison de l’étendue des trois paramètres de la K-distribution homodyne avec et sans propagation d’ondes de cisaillement a montré que les paramètres étaient significativement (p < 0,001) affectès par la propagation d’ondes de cisaillement dans les expériences in-vitro et ex-vivo. Les résultats ont également démontré que la plage dynamique des paramétres statistiques au cours de la propagation des ondes de cisaillement peut aider à discriminer (avec p < 0,001) les trois fantômes homogènes in-vitro les uns des autres, ainsi que les tumeurs de souris de leur milieu environnant dans les fantômes hétérogénes ex-vivo. De plus, un modéle de régression linéaire a été appliqué pour corréler la plage de l’intensité moyenne sous la propagation des ondes de cisaillement avec l’amplitude maximale de déplacement du « speckle » ultrasonore. La régression linéaire obtenue a été significative : fantômes in vitro : R2 = 0.98, p < 0,001 ; tumeurs ex-vivo : R2 = 0,56, p = 0,013 ; milieu environnant ex-vivo : R2 = 0,59, p = 0,009. En revanche, la régression linéaire n’a pas été aussi significative entre l’intensité moyenne sans propagation d’ondes de cisaillement et les propriétés mécaniques du milieu : fantômes in vitro : R2 = 0,07, p = 0,328, tumeurs ex-vivo : R2 = 0,55, p = 0,022 ; milieu environnant ex-vivo : R2 = 0,45, p = 0,047. Cette nouvelle approche peut fournir des informations supplémentaires à l’échographie quantitative statistique traditionnellement réalisée dans un cadre statique (c.-à-d., sans propagation d’ondes de cisaillement), par exemple, dans le contexte de l’imagerie ultrasonore en vue de la classification du cancer du sein. / In the context of breast tissue characterization, one may wonder what the consideration of a quantitative ultrasound (QUS) feature of a scattering medium (such as a soft biological tissue) under propagation of a shear wave adds to its discriminant power. This work presents a study of the time varying behavior of three statistical parameters (the mean intensity, the structure parameter and the clustering parameter of scatterers) of a general model for the ultrasound backscattering echo envelope (i.e., the homodyned K-distribution) under shear wave propagation. Transient shear waves were generated using the supersonic shear imaging (SSI) method in three in-vitro macroscopically homogenous breast mimicking phantoms with different mechanical properties, and two ex-vivo heterogeneous phantoms with mice tumors included in an agar gelatin surrounding medium. A comparison of the range of the three homodyned K-distribution parameters with and without shear wave propagation showed that the parameters were significantly (p < 0.001) affected by shear wave propagation in the in-vitro and ex-vivo experiments. The results also demonstrated that the dynamic range of the statistical parameters during shear wave propagation may help discriminate (with p < 0.001) the three in-vitro homogenous phantoms from each other, and also the mice tumors from their surrounding medium in the ex-vivo heterogeneous phantoms. Furthermore, a linear regression model was applied to relate the range of the mean intensity under shear wave propagation with the maximum displacement amplitude of speckle. The linear regression was found to be significant : in-vitro phantoms : R2 = 0.98, p < 0.001 ; ex-vivo tumors : R2 = 0.56, p = 0.013 ; ex-vivo surrounding medium : R2 = 0.59, p = 0.009. In contrast, the linear regression was not as significant between the mean intensity without shear wave propagation and mechanical properties of the medium : in-vitro phantoms : R2 = 0.07, p = 0.328, ex-vivo tumors : R2 =0.55, p = 0.022 ; ex-vivo surrounding medium : R2 = 0.45, p = 0.047. This novel approach may provide additional information to statistical QUS traditionally performed in a static framework (i.e., without shear wave propagation), for instance, in the context of ultrasound imaging for breast cancer classification.
42

Évaluation de la biomécanique cardiovasculaire par élastographie ultrasonore non-invasive

Porée, Jonathan 09 1900 (has links)
L’élastographie est une technique d’imagerie qui vise à cartographier in vivo les propriétés mécaniques des tissus biologiques dans le but de fournir des informations diagnostiques additionnelles. Depuis son introduction en imagerie ultrasonore dans les années 1990, l’élastographie a trouvé de nombreuses applications. Cette modalité a notamment été utilisée pour l’étude du sein, du foie, de la prostate et des artères par imagerie ultrasonore, par résonance magnétique ou en tomographie par cohérence optique. Dans le contexte des maladies cardiovasculaires, cette modalité a un fort potentiel diagnostique puisque l’athérosclérose modifie la structure des tissus biologiques et leurs propriétés mécaniques bien avant l’apparition de tout symptôme. Quelle que soit la modalité d’imagerie utilisée, l’élastographie repose sur : l’excitation mécanique du tissu (statique ou dynamique), la mesure de déplacements et de déformations induites, et l’inversion qui permet de recouvrir les propriétés mécaniques des tissus sous-jacents. Cette thèse présente un ensemble de travaux d’élastographie dédiés à l’évaluation des tissus de l’appareil cardiovasculaire. Elle est scindée en deux parties. La première partie intitulée « Élastographie vasculaire » s’intéresse aux pathologies affectant les artères périphériques. La seconde, intitulée « Élastographie cardiaque », s’adresse aux pathologies du muscle cardiaque. Dans le contexte vasculaire, l’athérosclérose modifie la physiologie de la paroi artérielle et, de ce fait, ses propriétés biomécaniques. La première partie de cette thèse a pour objectif principal le développement d’un outil de segmentation et de caractérisation mécanique des composantes tissulaires (coeur lipidique, tissus fibreux et inclusions calciques) de la paroi artérielle, en imagerie ultrasonore non invasive, afin de prédire la vulnérabilité des plaques. Dans une première étude (Chapitre 5), nous présentons un nouvel estimateur de déformations, associé à de l’imagerie ultrarapide par ondes planes. Cette nouvelle méthode d’imagerie permet d’augmenter les performances de l’élastographie non invasive. Dans la continuité de cette étude, on propose une nouvelle méthode d’inversion mécanique dédiée à l’identification et à la quantification des propriétés mécaniques des tissus de la paroi (Chapitre 6). Ces deux méthodes sont validées in silico et in vitro sur des fantômes d’artères en polymère. Dans le contexte cardiaque, les ischémies et les infarctus causés par l’athérosclérose altèrent la contractilité du myocarde et, de ce fait, sa capacité à pomper le sang dans le corps (fonction myocardique). En échocardiographie conventionnelle, on évalue généralement la fonction myocardique en analysant la dynamique des mouvements ventriculaires (vitesses et déformations du myocarde). L’abscence de contraintes physiologiques agissant sur le myocarde (contrairement à la pression sanguine qui contraint la paroi vasculaire) ne permet pas de résoudre le problème inverse et de retrouver les propriétés mécaniques du tissu. Le terme d’élastographie fait donc ici référence à l’évaluation de la dynamique des mouvements et des déformations et non à l’évaluation des propriétés mécanique du tissu. La seconde partie de cette thèse a pour principal objectif le développement de nouveaux outils d’imagerie ultrarapide permettant une meilleure évaluation de la dynamique du myocarde. Dans une première étude (Chapitre 7), nous proposons une nouvelle approche d’échocardiographie ultrarapide et de haute résolution, par ondes divergentes, couplée à de l'imagerie Doppler tissulaire. Cette combinaison, validée in vitro et in vivo, permet d’optimiser le contraste des images mode B ainsi que l’estimation des vitesses Doppler tissulaires. Dans la continuité de cette première étude, nous proposons une nouvelle méthode d’imagerie des vecteurs de vitesses tissulaires (Chapitre 8). Cette approche, validée in vitro et in vivo, associe les informations de vitesses Doppler tissulaires et le mode B ultrarapide de l’étude précédente pour estimer l’ensemble du champ des vitesses 2D à l’intérieur du myocarde. / Elastography is an imaging technique that aims to map the in vivo mechanical properties of biological tissues in order to provide additional diagnostic information. Since its introduction in ultrasound imaging in the 1990s, elastography has found many applications. This method has been used for the study of the breast, liver, prostate and arteries by ultrasound imaging, magnetic resonance imaging (MRI) or optical coherence tomography (OCT). In the context of cardiovascular diseases (CVD), this modality has a high diagnostic potential as atherosclerosis, a common pathology causing cardiovascular diseases, changes the structure of biological tissues and their mechanical properties well before any symptoms appear. Whatever the imaging modality, elastography is based on: the mechanical excitation of the tissue (static or dynamic), the measurement of induced displacements and strains, and the inverse problem allowing the quantification of the mechanical properties of underlying tissues. This thesis presents a series of works in elastography for the evaluation of cardiovascular tissues. It is divided into two parts. The first part, entitled « Vascular elastography » focuses on diseases affecting peripheral arteries. The second, entitled « Cardiac elastography » targets heart muscle pathologies. In the vascular context, atherosclerosis changes the physiology of the arterial wall and thereby its biomechanical properties. The main objective of the first part of this thesis is to develop a tool that enables the segmentation and the mechanical characterization of tissues (necrotic core, fibrous tissues and calcium inclusions) in the vascular wall of the peripheral arteries, to predict the vulnerability of plaques. In a first study (Chapter 5), we propose a new strain estimator, associated with ultrafast plane wave imaging. This new imaging technique can increase the performance of the noninvasive elastography. Building on this first study, we propose a new inverse problem method dedicated to the identification and quantification of the mechanical properties of the vascular wall tissues (Chapter 6). These two methods are validated in silico and in vitro on polymer phantom mimicking arteries. In the cardiac context, myocardial infarctions and ischemia caused by atherosclerosis alter myocardial contractility. In conventional echocardiography, the myocardial function is generally evaluated by analyzing the dynamics of ventricular motions (myocardial velocities and deformations). The abscence of physiological stress acting on the myocardium (as opposed to the blood pressure which acts the vascular wall) do not allow the solving the inverse problem and to find the mechanical properties of the fabric. Elastography thus here refers to the assessment of motion dynamics and deformations and not to the evaluation of mechanical properties of the tissue. The main objective of the second part of this thesis is to develop new ultrafast imaging tools for a better evaluation of the myocardial dynamics. In a first study (Chapter 7), we propose a new approach for ultrafast and high-resolution echocardiography using diverging waves and tissue Doppler. This combination, validated in vitro and in vivo, optimize the contrast in B-mode images and the estimation of myocardial velocities with tissue Doppler. Building on this study, we propose a new velocity vector imaging method (Chapter 8). This approach combines tissue Doppler and ultrafast B-mode of the previous study to estimate 2D velocity fields within the myocardium. This original method was validated in vitro and in vivo on six healthy volunteers.
43

Développement d’un système d’administration de l’anesthésie en boucle fermée

Charabati, Samer 03 1900 (has links)
En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle. / In the operating room, the anaesthetist performs numerous tasks. New technological tools better inform him about the state of the patient but render his task more demanding. To alleviate the anaesthetist workload, we have considered the automatic administration of anesthetic drugs using closed-loop control. In this respect, we have developed a system for the administration of an anesthetic agent (propofol) in order to maintain loss of consciousness at an optimal level throughout a surgery. The system comprises a computer, an anaesthesia monitor and an infusion pump. A control algorithm installed on the computer determines the infusion rate of the hypnotic drug based on the Bispectral IndexTM (BIS) provided by the monitor. At first, the anaesthetist chooses a target value for the control variable BIS and the algorithm, which consists of an expert system, calculates the infusion doses of propofol in order to steer the measured BIS value closer to the target value. For the user-interface of a novel anaesthesia monitor, four display types were considered: purely numeric, purely graphical, a mixed graphical and numerical and a bi-dimensional integrated graphical display. Based on 20 different scenarios where normal and abnormal anaesthesia parameters were presented to anaesthetists and residents, the study of the reaction time, response accuracy and user-friendliness (assessed by the NASA-TLX) showed that a mixed graphical and numerical display is the best preferred for the interface of the system. A clinical study was conducted in order to compare the behaviour of the system of administering propofol in closed-loop to manually controlled anaesthesia guided by BIS. After Institutional Review Board approval and written consent, 40 patients undergoing orthopaedic or general surgery were randomly assigned to 2 groups of equal size. After manual propofol induction (1.5 mg/kg), closed loop control was used to maintain anesthesia at a target BIS of 45 (Closed-loop group); in the other group, propofol was administered manually using a syringe pump by an experienced anaesthesiologist in order to maintain a target BIS of 45 as closely as possible (Control group). The performance of the system was defined as excellent, good, poor or inadequate, when the BIS was within 10%, between 10 and 20%, between 20 and 30% or outside 30% of the target BIS, respectively. In the Closed-loop group, the system showed excellent control during 55% of the total anaesthesia time, good control during 29% of the time and poor control during 9% of the time. The time from the end of infusion to extubation was 9 ± 3.7 min. In the Control group, excellent, good and poor control were noted during 33%, 33% and 15% of the time, respectively and doses were changed 9.5 ± 4 times per h. Extubation was achieved after 11.9 ± 3.3 min from the end of infusion. In the Closed-loop group, excellent control of anesthesia occurred significantly more often (P<0.0001) and inadequate control less often than in the Control group (P=0.001). The present system of administering propofol in closed-loop maintains the anesthesia level closer to a given target than manual administration.
44

Reactive Hyperemia as endothelial function determinant using plethysmography methods

Olamaei, Nina 01 1900 (has links)
L’atteinte de la fonction endothéliale représente une phase précoce de l’athérosclérose, un stade où les patients sont généralement asymptomatiques. Il existe donc un intérêt certain à détecter la dysfonction endothéliale. Nous avons développé une technique de mesure des variations de flot artériel au niveau des membres supérieurs, basée sur la spectroscopie proche infrarouge (NIRS). Cette approche permettrait d’étudier le niveau d’atteinte vasculaire et probablement de quantifier le degré de dysfonction endothéliale périphérique lors d’une hyperémie réactive. L'expérience a été exécutée sur deux cohortes de 13 et de 15 patients et a été comparée à la pléthysmographie par jauge de contrainte (SGP) qui est considérée comme une méthode de référence. Par la suite, nous avons caractérisé la réponse endothéliale par modélisation de la courbe hyperémique du flot artériel. Des études préliminaires avaient démontré que la réponse hyperémique adoptait majoritairement une forme bi-modale. Nous avons tenté de séparer les composantes endothéliales-dépendantes et endothéliales-indépendantes de l’hyperémie. La quantification des deux composantes de la réaction hyperémique permet de calculer un indice de la ‘santé’ du système endothélial local. Cet indice est nommé le ηfactor. Les résultats montrent une forte corrélation des mesures de flots entre la technique développée et la méthode de référence (r=0.91). Nous avons conclu que NIRS est une approche précise pour la mesure non-invasive du flot artériel. Nous avons obtenu une bonne répétabilité (ICC = 0.9313) pour le ηfactor indiquant sa robustesse. Cependant des études supplémentaires sont nécessaires pour valider la valeur de diagnostic du facteur défini. Mots clés: hyperémie réactive, réponse myogénique, oxyde nitrique, athérosclérose, spectroscopie proche infrarouge / Atherosclerotic diseases are mainly caused by coronary and peripheral blood vessel disorders. Endothelial dysfunction represents an early phase in these diseases, when patients are generally asymptomatic. We developed a technique, based on near infrared spectroscopy (NIRS), for measurement of arterial blood flow variations in limbs during reactive hyperemia. The technique allows the study of the level of vascular impairment and probably quantifying the level of endothelial dysfunction at peripheral arteries. The experiment was performed on two cohorts of 13 and 15 patients and was compared to strain gauge plethysmography (SGP) which is considered as gold standard. Afterward, we characterized endothelial reaction during reactive hyperemia through blood flow variations by modeling the hyperemic curve. Preliminary studies have shown that the hyperemic response generally adopts a bimodal form. The first peak was attributed to myogenic reaction that is endothelial independent and the second one to local endothelial cells reaction. The quantification of the two hyperemic response components makes it possible to calculate an index of ‘health’ for local endothelial cells, named ηfactor. The results showed a strong correlation (r = 0.91) of blood flow measurements between the developed method and the gold standard. We concluded that NIRS is a precise technique for non-invasive measurement of blood flow. Moreover, we found a high repeatability (ICC = 0.9313) of the ηfactor in repeated measurements indicating its robustness. Nonetheless, more studies are required to validate the diagnosis value of the defined factor. Key words: reactive hyperemia, myogenic response, endothelial dependent vasodilatation, nitric oxide, atherosclerosis, near infrared spectroscopy (NIRS)
45

Automaticité dans le coeur ischémique : analyse de bifurcation d’un modèle mathématique de cellule ventriculaire humaine

Bouchard, Sylvain 04 1900 (has links)
L’ischémie aigüe (restriction de la perfusion suite à l’infarctus du myocarde) induit des changements majeurs des propriétés électrophysiologique du tissu ventriculaire. Dans la zone ischémique, on observe une augmentation du potassium extracellulaire qui provoque l’élévation du potentiel membranaire et induit un "courant de lésion" circulant entre la zone affectée et saine. Le manque d’oxygène modifie le métabolisme des cellules et diminue la production d’ATP, ce qui entraîne l’ouverture de canaux potassique ATP-dépendant. La tachycardie, la fibrillation ventriculaire et la mort subite sont des conséquences possibles de l’ischémie. Cependant les mécanismes responsables de ces complications ne sont pas clairement établis. La création de foyer ectopique (automaticité), constitue une hypothèse intéressante expliquant la création de ses arythmies. Nous étudions l’effet de l’ischémie sur l’automaticité à l’aide d’un modèle mathématique de la cellule ventriculaire humaine (Ten Tusscher, 2006) et d’une analyse exhaustive des bifurcations en fonction de trois paramètres : la concentration de potassium extracellulaire, le "courant de lésion" et l’ouverture de canaux potassiques ATP-dépendant. Dans ce modèle, nous trouvons que seule la présence du courant de lésion peut entrainer une activité automatique. Les changements de potassium extracellulaire et du courant potassique ATP-dépendant altèrent toutefois la structure de bifurcation. / Acute ischemia (restriction in blood supply to part of the heart which can result in myocardial infarction) induces major changes in the electrophysiological properties of the ventricular tissue. Extracellular potassium concentration increases in the ischemic zone, leading to an elevation of the resting membrane potential that creates an “injury current” between the infarcted and the healthy zone. In addition, the lack of oxygen impairs the metabolic activity of the myocytes and decreases ATP production, thereby affecting ATP-sensitive potassium channels. A frequent complication of myocardial infarction is tachycardia, fibrillation and sudden cardiac death, but the mechanisms underlying their initiation are still debated. One hypothesis is that these arrhythmias may be triggered by abnormal automaticity. We have investigated the effect of ischemia on myocyte automaticity by performing a comprehensive bifurcation analysi(fixed points, cycles and their stability) of a human ventricular myocyte model (Ten Tusscher, 2006) as a function of three ischemia-relevant parameters: extracellular potassium, injury current, and ATP-sensitive potassium current. In this single-cell model, we found that automatic activity was possible only in the presence of an injury current. Changes in extracellular potassium and ATP-sensitive potassium current significantly altered the bifurcation structure as a function of IS, including the occurrence of early-after-depolarization. The results provide a sound basis for studying higher-dimensional tissue structures representing an ischemic heart.
46

Évaluation in silico des pompes d’assistance ventriculaire de type écoulement mixte

Nandlall, Ian 03 1900 (has links)
L'insuffisance cardiaque est une maladie à grande incidence dont le traitement définitif est difficile. Les pompes d'assistance ventriculaire ont été proposées comme thérapie alternative à long terme, mais la technologie est relativement jeune et selon son design, axial ou centrifuge, le dispositif favorise soit l'hémolyse, soit la stagnation de l'écoulement sanguin. Les pompes à écoulement mixte, combinant certaines propriétés des deux types, ont été proposées comme solution intermédiaire. Pour évaluer leurs performances, nous avons effectué des comparaisons numériques entre huit pompes, deux axiales, deux centrifuges, et quatre mixtes, en employant un modèle Windkessel du système cardiovasculaire avec paramètres optimisés pour l'insuffisance cardiaque résolu avec une méthode Radau IIA3, une méthode de résolution de système d'équations différentielles ordinaires L-stable appartenant à la famille des méthodes Runge-Kutta implicites. Nos résultats semblent suggérer que les pompes d'assistance mixtes ne démontrent qu'un léger avantage comparativement aux autres types en terme de performance optimale dans le cas de l'insuffisance cardiaque, mais il faudrait effectuer plus d'essais numériques avec un modèle plus complet, entre autres avec contrôles nerveux implémentés. / Heart failure is a disease with a high incidence rate that is difficult to treat definitively. Ventricular assist devices have been proposed as alternative long-term therapeutic options, but the technology is fairly recent and depending on the design, axial or centrifugal, the device will favor hemolysis or blood flow stagnation. Mixed flow devices, which combine properties of the two previous types, have therefore been proposed as intermediate solutions. To evaluate their performance, we did a numerical comparison between eight pumps (two axial, two centrifugal, and four mixed) using a Windkessel model of the cardiovascular system with parameters optimised for heart failure and solved using a Radau IIA3 method, an L-stable method used to numerically solve systems of ordinary differential equations that belongs to the family of implicit Runge-Kutta methods. Our results suggest that in terms of optimal performance, mixed flow pumps are modest improvements over the other two types, and more tests would have to be performed using a more complete model with, among other modifications, neural control systems implemented.
47

Développement d’un système de spectroscopie infrarouge résolue temporellement pour la quantification des concentrations d’hémoglobine cérébrale

Leclerc, Paul-Olivier 11 1900 (has links)
L’étude du cerveau humain est un domaine en plein essor et les techniques non-invasives de l’étudier sont très prometteuses. Afin de l’étudier de manière non-invasive, notre laboratoire utilise principalement l’imagerie par résonance magnétique fonctionnelle (IRMf) et l’imagerie optique diffuse (IOD) continue pour mesurer et localiser l’activité cérébrale induite par une tâche visuelle, cognitive ou motrice. Le signal de ces deux techniques repose, entre autres, sur les concentrations d’hémoglobine cérébrale à cause du couplage qui existe entre l’activité neuronale et le flux sanguin local dans le cerveau. Pour être en mesure de comparer les deux signaux (et éventuellement calibrer le signal d’IRMf par l’IOD), où chaque signal est relatif à son propre niveau de base physiologique inconnu, une nouvelle technique ayant la capacité de mesurer le niveau de base physiologique est nécessaire. Cette nouvelle technique est l’IOD résolue temporellement qui permet d’estimer les concentrations d’hémoglobine cérébrale. Ce nouveau système permet donc de quantifier le niveau de base physiologique en termes de concentrations d’hémoglobine cérébrale absolue. L’objectif général de ma maîtrise était de développer un tel système afin de l’utiliser dans une large étude portant sur la condition cardiovasculaire, le vieillissement, la neuroimagerie ainsi que les performances cognitives. Il a fallu tout d’abord construire le système, le caractériser puis valider les résultats avant de pouvoir l’utiliser sur les sujets de recherche. La validation s’est premièrement réalisée sur des fantômes homogènes ainsi qu’hétérogènes (deux couches) qui ont été développés. La validation des concentrations d’hémoglobine cérébrale a été réalisée via une tâche cognitive et appuyée par les tests sanguins des sujets de recherche. Finalement, on présente les résultats obtenus dans une large étude employant le système d’IOD résolue temporellement en se concentrant sur les différences reliées au vieillissement. / Our understanding of the functional organization of the human brain has been greatly influenced by the development of new medical imaging techniques. Pr. Hoge’s research has focused on the use of functional magnetic resonance imaging (fMRI) and continuous diffuse optical imaging (DOI) for non-invasive localization and quantification of brain activity associated with behavioral stimuli or tasks (e.g. cognitive, motor or visual). The respective signals of both techniques are based on cerebral haemoglobin concentrations because of the coupling that exists between neuronal activity and cerebral blood flow. Relating BOLD fMRI signals with those acquired using DOI has been complicated by the fact that fMRI yields fractional change values, while the majority of DOI methods have provided absolute changes from an unknown baseline. To address this, we adopted a newer technique known as time-resolved DOI, which allows absolute quantification of cerebral haemoglobin concentrations. Time-resolved DOI thus has the capacity to quantify the subject’s resting hemoglobin concentrations in absolute micromolar units. The main objective of my masters’ project was to implement and optimize a time-resolved DOI system for use in a large study exploring the links between cardiovascular fitness, aging, neuroimaging markers, and cognitive performance. In this thesis we describe the fabrication of the system, followed by its characterisation and validation using solid optical phantoms (homogeneous and heterogeneous) developed for this purpose. Haemoglobin concentrations obtained non-invasively with the system are validated against blood draws, while the sensitivity to variations in concentration are assessed during a cognitive task. Finally, we present the results of a large study in which the time-resolved DOI system was used to characterize age-related vascular changes in the brain.
48

Study on the activation of the biceps brachii compartments in normal subjects

Nejat, Nahal 08 1900 (has links)
Les prothèses myoélectriques modernes peuvent être dotées de plusieurs degrés de liberté ce qui nécessite plusieurs signaux musculaires pour en exploiter pleinement les capacités. Pour obtenir plus de signaux, il nous a semblé prometteur d'expérimenter si les 6 compartiments du biceps brachial pouvaient être mis sous tension de façon volontaire et obtenir ainsi 6 signaux de contrôle au lieu d'un seul comme actuellement. Des expériences ont donc été réalisées avec 10 sujets normaux. Des matrices d'électrodes ont été placées en surface au-dessus du chef court et long du biceps pour recueillir les signaux électromyographiques (EMG) générés par le muscle lors de contractions effectuées alors que les sujets étaient soit assis, le coude droit fléchi ~ 100 ° ou debout avec le bras droit tendu à l'horizontale dans le plan coronal (sur le côté). Dans ces deux positions, la main était soit en supination, soit en position neutre, soit en pronation. L'amplitude des signaux captés au-dessus du chef court du muscle a été comparée à ceux obtenus à partir du chef long. Pour visualiser la forme du biceps sous les électrodes l'imagerie ultrasonore a été utilisée. En fonction de la tâche à accomplir, l'activité EMG a était plus importante soit dans un chef ou dans l'autre. Le fait de pouvoir activer préférentiellement l'un des 2 chefs du biceps, même si ce n'est pas encore de façon complètement indépendante, suggère que l'utilisation sélective des compartiments pourrait être une avenue possible pour faciliter le contrôle des prothèses myoélectriques du membre supérieur. / The latest myoelectric prostheses have several degrees of freedom and therefore require a large number of myoelectric signals to fully exploit their capabilities. Muscle compartments, which are intra-muscular subdivisions innervated by an individual muscle nerve branch, can be exploited to provide additional independent muscle control sites to operate such prostheses. This research presents a work to investigate the activation of the 6 biceps brachii compartments in healthy subjects to see if they have the ability to activate those compartments voluntarily. Therefore, electromyographic (EMG) signals were recorded from an array of seven and ten pairs of equally spaced surface electrodes positioned across the short and long head of the biceps of ten healthy subjects. The EMG signals are collected in two positions: 1) with the subject seated, right elbow flexed ~100°, and 2) with the subject standing with the right arm extended horizontally in the coronal plane (90°shoulder abduction). In both positions, the hand is either fully supinated, neutral, or fully pronated. The average root mean square value of the EMG signals obtained from the pairs of electrodes positioned over the short head are compared with the average obtained for the other pairs placed over the biceps long head. Ultrasound imaging also used to visualize the long and short heads of the biceps in flexed and extended arm while the hand was in different postures. Depending on the task to be accomplished, activity was larger in one head or in the other. Being able to activate either head of the biceps, while not yet completely independently, suggests that the selective use of compartments could be a possible avenue for controlling upper limb myoelectric prostheses.
49

Analyse d’information tridimensionnelle issue de systèmes multi-caméras pour la détection de la chute et l’analyse de la marche

Auvinet, Edouard 11 1900 (has links)
Réalisé en cotutelle avec le laboratoire M2S de Rennes 2 / Cette thèse s’intéresse à définir de nouvelles méthodes cliniques d’investigation permettant de juger de l’impact de l’avance en âge sur la motricité. En particulier, cette thèse se focalise sur deux principales perturbations possibles lors de l’avance en âge : la chute et l’altération de la marche.Ces deux perturbations motrices restent encore mal connues et leur analyse en clinique pose de véritables défis technologiques et scientifiques. Dans cette thèse, nous proposons des méthodes originales de détection qui peuvent être utilisées dans la vie courante ou en clinique, avec un minimum de contraintes techniques. Dans une première partie, nous abordons le problème de la détection de la chute à domicile, qui a été largement traité dans les années précédentes. En particulier, nous proposons une approche permettant d’exploiter le volume du sujet, reconstruit à partir de plusieurs caméras calibrées. Ces méthodes sont généralement très sensibles aux occultations qui interviennent inévitablement dans le domicile et nous proposons donc une approche originale beaucoup plus robuste à ces occultations. L’efficacité et le fonctionnement en temps réel ont été validés sur plus d’une vingtaine de vidéos de chutes et de leurres, avec des résultats approchant les 100% de sensibilité et de spécificité en utilisant 4 caméras ou plus. Dans une deuxième partie, nous allons un peu plus loin dans l’exploitation des volumes reconstruits d’une personne, lors d’une tâche motrice particulière : la marche sur tapis roulant, dans un cadre de diagnostic clinique. Dans cette partie, nous analysons plus particulièrement la qualité de la marche. Pour cela nous développons le concept d’utilisation de caméras de profondeur pour la quantification de l’asymétrie spatiale au cours du mouvement des membres inférieurs pendant la marche. Après avoir détecté chaque pas dans le temps, cette méthode réalise une comparaison de surfaces de chaque jambe avec sa correspondante symétrique du pas opposé. La validation effectuée sur une cohorte de 20 sujets montre la viabilité de la démarche. / This thesis is concerned with defining new clinical investigation method to assess the impact of ageing on motricity. In particular, this thesis focuses on two main possible disturbance during ageing : the fall and walk impairment. This two motricity disturbances still remain unclear and their clinical analysis presents real scientist and technological challenges. In this thesis, we propose novel measuring methods usable in everyday life or in the walking clinic, with a minimum of technical constraints. In the first part, we address the problem of fall detection at home, which was widely discussed in previous years. In particular, we propose an approach to exploit the subject’s volume, reconstructed from multiple calibrated cameras. These methods are generally very sensitive to occlusions that inevitably occur in the home and we therefore propose an original approach much more robust to these occultations. The efficiency and real-time operation has been validated on more than two dozen videos of falls and lures, with results approaching 100 % sensitivity and specificity with at least four or more cameras. In the second part, we go a little further in the exploitation of reconstructed volumes of a person at a particular motor task : the treadmill, in a clinical diagnostic. In this section we analyze more specifically the quality of walking. For this we develop the concept of using depth camera for the quantification of the spatial and temporal asymmetry of lower limb movement during walking. After detecting each step in time, this method makes a comparison of surfaces of each leg with its corresponding symmetric leg in the opposite step. The validation performed on a cohort of 20 subjects showed the viability of the approach.
50

Modulation de l'activité de structures cérébrales sous-corticales par optogénétique

Castonguay, Alexandre 03 1900 (has links)
L’optogénétique est une technique prometteuse pour la modulation de l’activité neuronale. Par l’insertion d’une opsine microbienne dans la membrane plasmique de neurones et par son activation photonique, il devient possible de réguler l’activité neuronale avec une grande résolution temporelle et spatiale. Beaucoup de travaux ont été faits pour caractériser et synthétiser de nouvelles opsines. Ainsi, plusieurs variétés d’opsines sont désormais disponibles, chacune présentant des cinétiques et sensibilités à des longueurs d’onde différentes. En effet, il existe des constructions optogénétiques permettant de moduler à la hausse ou à la baisse l’activité neuronale, telles la channelrhodopsine-2 (ChR2) ou la halorhodopsine (NpHR), respectivement. Les promesses de cette technologie incluent le potentiel de stimuler une région restreinte du cerveau, et ce, de façon réversible. Toutefois, peu d’applications en ce sens ont été réalisées, cette technique étant limitée par l’absorption et la diffusion de la lumière dans les tissus. Ce mémoire présente la conception d’une fibre optique illuminant à un angle de 90° à sa sortie, capable de guider la lumière à des structures bien précises dans le système nerveux central. Nous avons conduit des tests in vivo dans le système visuel de souris transgéniques exprimant la ChR2 dans l’ensemble du système nerveux central. Dans le système visuel, les signaux rétiniens sont conduits au corps genouillé latéral (CGL) avant d’être relayés au cortex visuel primaire (V1). Pour valider la capacité de mon montage optogénétique à stimuler spécifiquement une sous-population de neurones, nous avons tiré profit de l’organisation rétinotopique existant dans le système visuel. En stimulant optogénétiquement le CGL et en tournant la fibre optique sur elle-même à l’aide d’un moteur, il devient possible de stimuler séquentiellement différentes portions de cette structure thalamique et conséquemment, différentes représentations du champ visuel. L’activation des projections thalamiques sera enregistrée au niveau de l’aire V1 à l’aide de l’imagerie optique intrinsèque, une technique qui permet d’imager les variations de la concentration d’oxygène et du volume sanguin dans le tissu neuronal, sur une grande surface corticale. Comme l’organisation rétinotopique est maintenue au niveau de l’aire V1, l’espace activé au niveau du cortex révèlera l’étendue spatiale de notre stimulation optogénétique du CGL. Les expériences in vivo démontrèrent qu’en déplaçant la fibre optique dans le CGL, il nous était possible de stimuler différents sous- ensembles de neurones dans cette structure thalamique. En conclusion, cette étude montre notre capacité à développer un système à base de fibre optique capable de stimuler optogénétiquement une population de neurone avec une grande précision spatiale. / Optogentics is a promising technic for neuronal activity modulation. By inserting a microbial opsin in the plasma membrane and by its photonic activation, it is possible to regulate neuronal activity with high temporal and spatial resolution. A lot of work has been done to characterize and synthetize new opsins. Thus, a wide variety of opsins are now available, presenting different kinetics and sensibility to specific wavelengths. Indeed, different opsins can either increase or decrease neuronal activity such as channelrhodopsin-2 (ChR2) or halorhodopsin (NpHR), respectively. This technology has the potential to stimulate a specific region within the brain in a highly reversible manner. However, little work was accomplished in this way, because to limitations due to absorption and scattering of light in biological tissue. This master’s thesis presents the conception of a side-firing optical fiber, capable of guiding light to specific structures within the brain. We conducted in vivo experiments in the visual system of transgenic mice expressing ChR2 in the entire central nervous system. In the visual system, retinal inputs are relayed to the lateral geniculate nucleus (LGN) before reaching the primary visual cortex (V1). To validate the capacity of the designed optogenetic assembly to stimulate specific sub-populations of neurons, we took advantage of the retinotopic organization existing in the visual system. By optogenetically stimulating the LGN and rotating the optical fiber around its axis with a motor, it is possible to sequentially stimulate different portions of this thalamic structure and consequently, different portions of the visual field. Activation of thalamic projections will be recorded in area V1 using intrinsic optical imaging, a technic allowing to image variations of blood oxygenation and blood volume in neuronal tissue over large cortical areas. Activation at the level of the cortex will reveal the spatial extent of the optogenetic stimulation in the LGN as retinotopic organization is maintained in V1 cortical area. In vivo experiments showed that displacing the optical fiber in the LGN allowed stimulation of different neuronal populations within this thalamic structure. In conclusion, this study demonstrates our capacity to develop a fiber-based system capable of optogenetically stimulating neuronal tissue with high spatial precision.