• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 64
  • 48
  • Tagged with
  • 195
  • 195
  • 145
  • 132
  • 128
  • 128
  • 54
  • 47
  • 47
  • 47
  • 46
  • 40
  • 30
  • 28
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Segmentation et quantification des couches rétiniennes dans des images de tomographie de cohérence optique, dans le cas de sujets sains et pathologiques

Ghorbel, Itebeddine 12 April 2012 (has links) (PDF)
La tomographie de cohérence optique (OCT) est une technique d'imagerie non invasive, fondée sur le principe de l'interférométrie. Elle est maintenant un examen classique pour le dépistage et le suivi des affections rétiniennes, notamment des dégénérescences maculaires. C'est dans ce cadre que s'inscrit le premier objectif de ces travaux de thèse, où nous proposons une nouvelle méthode de segmentation des images OCT de sujets sains. Les principales difficultés sont liées au bruit des images, à la variabilité de la morphologie d'un patient à l'autre et aux interfaces mal définies entre les différentes couches. Notre nouvelle approche est fondée sur des algorithmes de segmentation plus globaux. Ainsi, huit couches rétiniennes peuvent être détectées, y compris les segments internes (IS) des photorécepteurs. L'évolution lente des maladies rétiniennes pose le problème de l'évaluation de ces thérapeutiques. C'est dans ce cadre que s'inscrit le second objectif de cette thèse, où nous étendons le champ d'application des méthodes développées pour les sujets sains aux sujets atteints de rétinopathie pigmentaire. Nous avons ainsi développé un nouveau modèle paramétrique déformable qui intègre les informations a priori en ajoutant une contrainte de parallélisme. Dans les cas sains et pathologiques, nous avons réalisé une évaluation exhaustive qualitative et quantitative. Les résultats de segmentation automatique ont été comparés avec les segmentations manuelles réalisées par différents experts. Ces évaluations montrent une très bonne concordance et une forte corrélation entre les segmentations automatiques et les segmentations faites manuellement par un expert.
82

Urologie & Gestes Médico-Chirurgicaux Assistés par Ordinateur (GMCAO)

Mozer, Pierre 14 June 2007 (has links) (PDF)
Cette thèse, ayant comme thème scientifique le recalage qu'il soit géométrique ou iconique, décrit trois applications cliniques dans le domaine de l'urologie. Elle s'appuie en grande partie sur l'utilisation de l'échographie comme capteur peropératoire.<br />Elle présente trois chapitres :<br />1. La ponction du rein dont le but est d'atteindre par voie percutanée une cible à l'intérieur du rein. Dans un premier temps, une approche de recalage par une mise en correspondance de nuages de points d'image échographiques et scanner est décrite avant l'évaluation d'une approche iconique sur fantôme et sur un sujet sain. Dans un second temps, une approche consistant à mettre en correspondance de façon automatique, à l'aide d'un localisateur externe, le trajet de ponction échographique dans des images de fluoroscopie est décrite puis validée sur fantôme et 11 patients.<br />2. La ponction des trous sacrés dans le but de placer une aiguille au contact des racines de nerfs sacrés. Nous décrivons une approche consistant à recaler par une approche géométrique des images scanner et échograpiques en détectant dans les images scanner l'interface os/muscle visible en échographie. Nous décrivons les expériences sur un fantôme et un sujet anatomique.<br />3. Le dernier chapitre décrit le développement de deux applications concernant le cancer de la prostate. La première est la reconstruction d'images 3D anatomopathologique de la prostate et leur recalage avec des images IRM dans le but de développer un atlas statistique de la distribution du cancer et d'améliorer la sémiologie radiologique. La méthode est décrite à partir de données de sujets anatomiques et d'un patient. La seconde est la localisation des biopsies de prostate par voie endorectale en employant une approche de recalage iconique échographique 3D monomodale afin d'améliorer la cartographie biopsique qui est essentielle pour le diagnostic et la prise en charge du cancer. Contrairement aux méthodes précédentes de recalage peropératoire décrite dans cette thèse, celle-ci est uniquement basée sur les images et permet donc de s'affranchir de l'utilisation d'un localisateur externe. Notre approche est validée par une étude clinique sur 14 patients.
83

Méthode numérique d'estimation du mouvement des masses molles

Thouzé, Arsène 10 1900 (has links)
L’analyse biomécanique du mouvement humain en utilisant des systèmes optoélectroniques et des marqueurs cutanés considère les segments du corps comme des corps rigides. Cependant, le mouvement des tissus mous par rapport à l'os, c’est à dire les muscles et le tissu adipeux, provoque le déplacement des marqueurs. Ce déplacement est le fait de deux composantes, une composante propre correspondant au mouvement aléatoire de chaque marqueur et une composante à l’unisson provoquant le déplacement commun des marqueurs cutanés lié au mouvement des masses sous-jacentes. Si nombre d’études visent à minimiser ces déplacements, des simulations ont montré que le mouvement des masses molles réduit la dynamique articulaire. Cette observation est faite uniquement par la simulation, car il n'existe pas de méthodes capables de dissocier la cinématique des masses molles de celle de l’os. L’objectif principal de cette thèse consiste à développer une méthode numérique capable de distinguer ces deux cinématiques. Le premier objectif était d'évaluer une méthode d'optimisation locale pour estimer le mouvement des masses molles par rapport à l’humérus obtenu avec une tige intra-corticale vissée chez trois sujets. Les résultats montrent que l'optimisation locale sous-estime de 50% le déplacement des marqueurs et qu’elle conduit à un classement de marqueurs différents en fonction de leur déplacement. La limite de cette méthode vient du fait qu'elle ne tient pas compte de l’ensemble des composantes du mouvement des tissus mous, notamment la composante en unisson. Le second objectif était de développer une méthode numérique qui considère toutes les composantes du mouvement des tissus mous. Plus précisément, cette méthode devait fournir une cinématique similaire et une plus grande estimation du déplacement des marqueurs par rapport aux méthodes classiques et dissocier ces composantes. Le membre inférieur est modélisé avec une chaine cinématique de 10 degrés de liberté reconstruite par optimisation globale en utilisant seulement les marqueurs placés sur le pelvis et la face médiale du tibia. L’estimation de la cinématique sans considérer les marqueurs placés sur la cuisse et le mollet permet d'éviter l’influence de leur déplacement sur la reconstruction du modèle cinématique. Cette méthode testée sur 13 sujets lors de sauts a obtenu jusqu’à 2,1 fois plus de déplacement des marqueurs en fonction de la méthode considérée en assurant des cinématiques similaires. Une approche vectorielle a montré que le déplacement des marqueurs est surtout dû à la composante à l’unisson. Une approche matricielle associant l’optimisation locale à la chaine cinématique a montré que les masses molles se déplacent principalement autour de l'axe longitudinal et le long de l'axe antéro-postérieur de l'os. L'originalité de cette thèse est de dissocier numériquement la cinématique os de celle des masses molles et les composantes de ce mouvement. Les méthodes développées dans cette thèse augmentent les connaissances sur le mouvement des masses molles et permettent d’envisager l’étude de leur effet sur la dynamique articulaire. / Biomechanical analysis of human movement using optoelectronic system and skin markers considers body segments as rigid bodies. However the soft tissue motion relative to the bone, including muscles, fat mass, results in relative displacement of markers. This displacement is the results of two components, an own component which corresponds to a random motion of each marker and an in-unison component corresponding to the common movement of skin markers resulting from the movement of the underlying wobbling mass. While most studies aim to minimize these displacements, computer simulation models have shown that the movement of the soft tissue motion relative to the bones reduces the joint kinetics. This observation is only available using computer simulations because there are no methods able to distinguish the kinematics of wobbling mass of the bones kinematics. The main objective of this thesis is to develop a numerical method able to distinguish this different kinematics. The first aim of this thesis was to assess a local optimisation method for estimating the soft tissue motion using intra-cortical pins screwed into the humerus in three subjects. The results show that local optimisation underestimates of 50% the marker displacements. Also it leads to a different marker ranking in terms of displacement. The limit of local optimisation comes from the fact that it does not consider all the components of the soft tissue motion, especially the in-unison component. The second aim of this thesis was to develop a numerical method that accounts for all the component of the soft tissue motion. More specifically, this method should provide similar kinematics and estimate large marker displacement and distinguish the two components to conventional approaches. The lower limb is modeled using a 10 degree of freedom chain model reconstructed using global optimisation and the markers placed only on the pelvis and the medial face of the shank. The original estimate of joint kinematics without considering the markers placed on the thigh and on the calf avoids the influences of these markers displacement on the kinematic model reconstruction. This method was tested on 13 subjects who performed hopping trials and obtained up to 2.1 times of marker displacement depending the method considered ensuring similar joint-kinematics. A vector approach shown that marker displacements is more induce by the in-unison component. A matrix approach combining the local optimisation and the kinematic model shown that the wobbling mass moves around the longitudinal axis and along the antero-posterior axis of the bone. The originality of this thesis is to numerically distinguish the bone kinematics from the wobbling mass kinematics and the two components of the soft tissue motion. The methods developed in this thesis increases the knowledge on soft tissue motion and allow future studies to consider their movement in joint kinetics calculation.
84

Vector flow mapping using plane wave ultrasound imaging

Dort, Sarah 12 1900 (has links)
Les diagnostics cliniques des maladies cardio-vasculaires sont principalement effectués à l’aide d’échographies Doppler-couleur malgré ses restrictions : mesures de vélocité dépendantes de l’angle ainsi qu’une fréquence d’images plus faible à cause de focalisation traditionnelle. Deux études, utilisant des approches différentes, adressent ces restrictions en utilisant l’imagerie à onde-plane, post-traitée avec des méthodes de délai et sommation et d’autocorrélation. L’objectif de la présente étude est de ré-implémenté ces méthodes pour analyser certains paramètres qui affecte la précision des estimations de la vélocité du flux sanguin en utilisant le Doppler vectoriel 2D. À l’aide d’expériences in vitro sur des flux paraboliques stationnaires effectuées avec un système Verasonics, l’impact de quatre paramètres sur la précision de la cartographie a été évalué : le nombre d’inclinaisons par orientation, la longueur d’ensemble pour les images à orientation unique, le nombre de cycles par pulsation, ainsi que l’angle de l’orientation pour différents flux. Les valeurs optimales sont de 7 inclinaisons par orientation, une orientation de ±15° avec 6 cycles par pulsation. La précision de la reconstruction est comparable à l’échographie Doppler conventionnelle, tout en ayant une fréquence d’image 10 à 20 fois supérieure, permettant une meilleure caractérisation des transitions rapides qui requiert une résolution temporelle élevée. / Clinical diagnosis of cardiovascular disease is dominated by colour-Doppler ultrasound despite its limitations: angle-dependent velocity measurements and low frame-rate from conventional focusing. Two studies, varying in their approach, address these limitations using plane-wave imaging, post-processed with the delay-and-sum and autocorrelation methods. The aim of this study is to re-implement these methods, investigating some parameters which affect blood velocity estimation accuracy using 2D vector-Doppler. Through in vitro experimentation on stationary parabolic flow, using a Verasonics system, four parameters were tested on mapping accuracy: number of tilts per orientation, ensemble length for single titled images, cycles per transmit pulse, and orientation angle at various flow-rates. The optimal estimates were found for 7 compounded tilts per image, oriented at ±15° with 6 cycles per pulse. Reconstruction accuracies were comparable to conventional Doppler; however, maintaining frame-rates more than 10 to 20 times faster, allowing better characterization of fast transient events requiring higher temporal resolution.
85

Back muscles activity and scoliosis in ataxic and dystrophic patients

Sleem, Fawzieh 12 1900 (has links)
To investigate the role of muscles in the development of adolescent idiopathic scoliosis (AIS), our group was initially interested in Duchenne muscular dystrophy (DMD) diseases where a muscular degeneration often leads to scoliosis. Few years ago the studies with those patients provided interesting results but were obtained only from few patients. To increase that number, the present project was initiated but recruitment of new DMD patients from Marie-Enfant hospital was found impossible. As an alternative, patients with Friedreich’s ataxia (FA) were recruited since they also suffer from a muscular deficiency which often induces a scoliosis. So, 4 FA patients and 4 healthy controls have been chosen to closely match the age, weight and body mass indexes (BMI) of the patients were enrolled in our experiments. As in the previous study, electromyography (EMG) activity of paraspinal muscles were recorded on each side of the spine during three types of contraction at 2 different maximum voluntary contractions (MVC). Moreover, the volume and skinfold thickness of these muscles were determined from ultrasound images (US) in order to facilitate the interpretation of EMG signals recorded on the skin surface. For the 3 FA right scoliotic patients, EMG activity was most of the time larger on the concave side of the deviation. The opposite was found for the 4th one (P4, left scoliosis, 32°) for whom EMG activity was larger on the convex side; it should however be noted that all his signals were of small amplitude. This was associated to a muscle weakness and a large skinfold thickness (12 mm) vs 7 mm for the 3 others. As for the paraspinal muscle volume, it was present on the convex side of P1, P3 and P4 and on the concave side for P2. As for skinfold thickness over this muscle, it was larger on the concave side for P1 and P2 and the opposite for P3 and P4. At the apex of each curve, the volume and skinfold thickness differences were the largest. Although the study covers only a small number of FA patients, the presence of larger EMG signals on the concave side of a spinal deformation is similar to pre-scoliotic DMD patients for whom the deformation is in its initial stage. It thus seems that our FA patients with more EMG activity on their concave side could see progression of their spinal deformation in the coming months in spite of their already important Cobb angle. / Pour étudier le rôle des muscles dans le développement de la scoliose idiopathique de l’adolescent (SIA), d’abord notre groupe était intéressé par la myopathie de Duchenne (DMD) où une dégénérescence musculaire conduit souvent à la scoliose. Il y a quelques années, des résultats intéressants étaient obtenus par les études avec ces patients, mais seulement de quelques patients. Pour augmenter ce nombre, le présent projet a été lancé, mais le recrutement de nouveaux patients atteints de DMD a été trouvé impossible dans l’hôpital de Marie-Enfant. Comme alternative, les patients atteints de l’ataxie de Friedriech (AF) ont recruté qui provoque un affaiblissement musculaire menant souvent à une scoliose. Ainsi, 4 patients AF et 4 jeunes sains asymptomatiques constituant le groupe contrôle ont été recruté dans nos expériences. Comme dans l’étude précédente, les signaux électromyographiques (EMG) des muscles paraspinaux ont été captés lors de 3 types de contraction à deux différentes contractions volontaires maximales. En outre, l'épaisseur du pli cutané et du volume de ces muscles ont été déterminées à partir des images échographiques en vue de faciliter l’interprétation des signaux EMG enregistrés à la surface de la peau. Pour les 3 patients présentaient une scoliose à droite, une activité EMG a été la plupart du temps plus grande sur le côté concave de la déviation. Le contraire a été trouvé chez le 4ième patient (scoliose à gauche, 32°) chez qui l’activité EMG était plus grande sur le côté convexe. Il est à noter que ses signaux EMG étaient très faibles dû à une faiblesse musculaire et à une épaisseur du pli cutané plus grande (12 mm vs 7 mm) pour les 3 autres. En ce qui concerne le volume des muscles paraspinaux, il était plus grand du côté convexe pour P1, P3 et P4 et du côté concave pour P2. Quant à l'épaisseur du pli cutané au-dessus des paraspinaux, il était plus grand du côté concave pour P1 et P2 et c’était l'inverse pour P3 et P4. Ces différences de volume et d'épaisseur du pli cutané étaient plus grandes au voisinage de l’apex des courbes scoliotiques. Bien que l'étude ne porte que sur un petit nombre de patients atteints de l’ataxie de Friedreich (AF), la présence de signaux EMG plus grands du côté concave de leur déformation vertébrale est à le semblable de ce que nous avons observé chez les patients DMD chez qui une scoliose débutait, une plus grande activité EMG a été détectée sur le côté concave. Il semble donc que les patients AF ayant une activité EMG plus grande du côté concave, pourraient voir leur déformation progresser au cours des prochains mois malgré le fait que leur angle de Cobb soit déjà important.
86

De la modélisation à la quantification par ultrasons de l'agrégation érythrocytaire

Traoré-Dubuis, Ali 06 1900 (has links)
Plusieurs études ont démontré une association entre l’agrégation érythrocytaire du milieu sanguin et plusieurs anomalies hémorhéologiques. Cette agrégation peut être quantifiée à l'aide du coefficient de rétrodiffusion ultrasonore. Pour décrire l’interaction entre l'onde ultrasonore et les tissus biologiques, on se sert de modèles. Ainsi, le modèle de facteur de structure (MFS) est utilisé pour évaluer le coefficient de rétrodiffusion des globules rouges agrégés. Toutefois, ce modèle numérique ne permet pas des mesures en temps réel du niveau d’agrégation et n'informe pas sur la structure du milieu sanguin comme par exemple la taille de l’agrégat. Pour pallier à ces difficultés, nous proposons un modèle où la théorie du milieu effectif est combinée au modèle de facteur de structure. Tout en permettant une mesure en temps réel de l’agrégation, ce modèle nommé TMEMFS fournit en plus deux indices structuraux de l’agrégation: le rayon de l’agrégat ainsi que sa compacité. Par le biais de simulations numériques en 3D, on a comparé le coefficient de rétrodiffusion suivant les modèles MFS et TMEMFS. Ceci dans le but de vérifier que dans la solution du problème direct, les propriétés acoustiques des globules rouges et les propriétés structurales du milieu agrégeant correspondaient à la réalité. Pour simuler des agrégats de globules rouges, une disposition hexagonale compacte a été utilisée. Les effets du rayon et de la compacité sur le coefficient de rétrodiffusion ont été étudiés. Basé sur la microstructure sanguine considérée, les résultats obtenus avec le modèle TMEMFS sont semblables à ceux du modèle MFS. Ce travail constitue un support théorique pour une mesure quantitative in vivo de l’agrégation érythrocytaire à des fins diagnostics. / Many studies have reported that an enhanced level of red blood cell aggregation is associated with the presence of hemorheological disorders. Pathological aggregation has been characterized by quantitative ultrasound based on the backscattering coefficient. In order to describe the interaction between the incident ultrasound and the interrogated biological tissues, mathematical models are used. Mathematical modeling is known to be the optimal way to describe the interaction occurring between ultrasound and tissues at the cellular level. The structure factor model (SFM), considered as the exact scattering model has been developed to predict the backscattering coefficient from blood. However, the numerical SFM cannot be applied in real time for practical measurements and does not provide aggregate size to assess the level of aggregation. Therefore, we come up with a new model based on the effective medium theory in order to tackle this difficulty. The effective medium theory combined with the structure factor model (EMTSFM) can be applied in real time and contrary to the SFM provides two indices of the aggregate state in vivo: aggregate size and compactness. Based on a 3D simulation study, the backscattering coefficients (BSCs) predicted by the effective medium theory combined with the Structure Factor Model (EMTSFM) are compared to the BSCs computed with SFM. Our aim here is to assess the accuracy of the EMTSFM against the SFM by comparing their BSC in the framework of a forward problem, i.e., the calculation of the BSC from the known acoustic and structure aggregate parameters. This was done in order to validate the proposed model. To simulate aggregates, RBCs are stacked following a hexagonal close packing scheme. The influences of the aggregate radius and compactness on the BSC are studied as well. The results showed good agreement between the SFM and the EMTSFM based on our simulated microstructure of RBC aggregates. Our work provides thus the theoretical background to assess locally the aggregation level for diagnosis purposes. / Le travail a été réalisé en collaboration avec le laboratoire de mécanique acoustique de Marseille, France. Les simulations ont été menées avec les langages Matlab et C. Ce projet s'inscrit dans le champ de recherche dénommé caractérisation tissulaire par ultrasons.
87

Fabrication de microstructures pour le recrutement de protéines synaptiques par polymérisation à deux photons

Gagnon, Maxime 12 1900 (has links)
No description available.
88

Dynamics underlying epileptic seizures: insights from a neural mass model

Fan, Xiaoya 17 December 2018 (has links) (PDF)
In this work, we propose an approach that allows to explore the potential pathophysiological mechanisms (at neuronal population level) of ictogenesis by combining clinical intracranial electroencephalographic (iEEG) recordings with a neural mass model. IEEG recordings from temporal lobe epilepsy (TLE) patients around seizure onset were investigated. Physiologically meaningful parameters (average synaptic gains of the excitatory, slow and fast inhibitory population, Ae, B and G) were identified during interictal to ictal transition. We analyzed the temporal evolution of four ratios, i.e. Ae/G, Ae/B, Ae/(B + G), and B/G. The excitation/inhibition ratio increased around seizure onset and decreased before seizure offset, suggesting the disturbance and restoration of balance between excitation and inhibition around seizure onset and before seizure offset, respectively. Moreover, the slow inhibition may have an earlier effect on the breakdown of excitation/inhibition balance. Results confirm the decrease in excitation/inhibition ratio upon seizure termination in human temporal lobe epilepsy, as revealed by optogenetic approaches both in vivo in animal models and in vitro. We further explored the distribution of the average synaptic gains in parameter space and their temporal evolution, i.e. the path through the model parameter space, in TLE patients. Results showed that the synaptic gain values located roughly on a plane before seizure onset, dispersed during ictal and returned when the seizure terminated. Cluster analysis was performed on seizure paths and demonstrated consistency in synaptic gain evolution across different seizures from individual patients. Furthermore, two patient groups were identified, each one corresponding to a specific synaptic gain evolution in the parameter space during a seizure. Results were validated by a bootstrapping approach based on comparison with random paths. The differences in the path revealed variations in EEG dynamics for patients despite showing an identical seizure onset pattern. Our approach may have the potential to classify the epileptic patients into subgroups based on different mechanisms revealed by subtle changes in synaptic gains and further enable more robust decisions regarding treatment strategy. The increase of excitation/inhibition ratios, i.e. Ae/G, Ae/B and Ae/(B+G), around seizure onset makes them potential cues for seizure detection. We explored the feasibility of a model based seizure detection algorithm. A simple thresholding method was employed. We evaluated the algorithm against the manual scoring of a human expert on iEEG samples from patients suffering from different types of epilepsy. Results suggest that Ae/(B+G), i.e. excitation/(slow + fast inhibition) ratio, allowed the best performance and that the algorithm best suited TLE patients. Leave-one-out cross-validation showed that the algorithm achieved 94.74% sensitivity for TLE patients. The median false positive rate was 0.16 per hour, and median detection delay was -1.0 s. Of interest, the values of the threshold determined by leave-one-out cross-validation for TLE patients were quite constant, suggesting a general excitation/inhibition balance baseline in background iEEG among TLE patients. Such a model-based seizure detection approach is of clinical interest and could also achieve good performance for other types of epilepsy provided that more appropriate model, i.e. better describe epileptic EEG waveforms for other types of epilepsy, is implemented. Altogether, this thesis contributes to the field of epilepsy research from two perspectives. Scientifically, it gives new insights into the mechanisms underlying interictal to ictal transition, and facilitates better understanding of epileptic seizures. Clinically, it provides a tool for reviewing EEG data in a more efficient and objective manner and offers an opportunity for on-demand therapeutic devices. / Doctorat en Sciences de l'ingénieur et technologie / info:eu-repo/semantics/nonPublished
89

Etude des bases neurales du couplage entre cinématique du mouvement et activités neuromagnétiques

Marty, Brice 27 February 2018 (has links)
Le but de ce travail a été d’étudier le couplage entre la cinématique du mouvement et l’activité neuromagnétique du cerveau humain, de comprendre les mécanismes neuronaux à la base de ce couplage, et d’essayer de répondre, notamment grâce à l’utilisation de la cohérence cortico-cinématique, à un certain nombre de questions posées par le traitement de la cinématique d’un mouvement des doigts (exécuté ou observé) par le cerveau.Ce travail de thèse de doctorat démontre en 5 études originales que(i) la fréquence de mouvement n’a pas d’impact sur le niveau de couplage ni sur la localisation de la source principale de ce couplage pendant des mouvements volontaires des doigts (étude I), (ii) la cinématique de mouvements (dirigés vers un but) observés de la main d’autrui est couplée à l’activité du cerveau de l’observateur dans la partie postérieure du gyrus temporal supérieur droit, les lobules supra temporaux et cortex SM1 bilatéraux de la même manière que durant l’exécution d’un mouvement similaire (étude II),(iii) l’amplitude de la bande β des cortex SM1 bilatéraux est modulée par la cinématique de mouvements répétitifs de la main dirigés vers un but, et ce, de la même manière lors de l’exécution où de l’observation de cette action. Cette modulation ne semble pas être liée au phénomène de CKC (étude III), (iv) Ce couplage est réduit de manière significative chez les patients souffrant d’ataxie de Friedreich et ce, tant pour des mouvements actifs que passifs, ce qui apporte de nouvelles évidences en faveur du rôle prépondérant des afférences proprioceptives dans le phénomène CKC. De plus, la CKC corrèle de manière significative avec l’expansion de triplet GAA1 et pas avec les scores cliniques SARA plaidant ainsi pour une altération génétiquement déterminée et stable des afférences proprioceptives dans la maladie de Friedreich (étude IV),(v) l’activité magnétique du lobe postérieur du cervelet ipsilatéral au mouvement est couplée avec la cinématique de ce mouvement sans influence de la fréquence du mouvement (étude V). / Doctorat en Sciences biomédicales et pharmaceutiques (Médecine) / info:eu-repo/semantics/nonPublished
90

Développement d’un système d’imagerie haute vitesse pour la surveillance en continue de cultures cardiaques

Belzil, Antoine 12 1900 (has links)
No description available.

Page generated in 0.1181 seconds