81 |
Influencia da redução medicamentosa da pressão intra-ocular na medida da espessura da camada de fibras nervosas da retina de olhos hipertensos e glaucomatosos pela polarimetria de varredura a laser / The influence of intraocular pessure reduction with medication on retinal nerve fiber layer thickness measurements obtained with scanning laser polarimetry in glaucomatous and hypertensive eyesAvelino, Rodrigo Rezende Gomes 27 August 2007 (has links)
Orientador: Vital Paulino Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T04:54:16Z (GMT). No. of bitstreams: 1
Avelino_RodrigoRezendeGomes_M.pdf: 2930957 bytes, checksum: c66d1b04f0e830ee3e2b0a2e3897981b (MD5)
Previous issue date: 2007 / Resumo: Objetivo: Avaliar o efeito da redução da pressão intra-ocular (PIO) obtido com o uso de terapia medicamentosa na espessura da camada de fibras nervosas da retina medida pela Polarimetria de Varredura a Laser (PVL) em pacientes glaucomatosos ou hipertensos oculares. Métodos: Trinta e sete olhos de 37 pacientes foram prospectivamente incluídos no estudo e avaliados com a PVL sem uso de medicação ocular hipotensora e num período entre 15 e 30 dias após a instituição de medicação ocular hipotensora, que resultou em redução da PIO de pelo menos 25%. Os parâmetros medidos pela PVL antes e após a redução da PIO foram comparados com o teste t de Student pareado. Resultados: A PIO média dos 37 pacientes diminuiu significativamente de 26,57 ± 4,23 mmHg para 16,54 ± 2,92 mmHg (p<0,05) após terapia medicamentosa. Não houve diferença estatisticamente significativa entre os valores dos 10 parâmetros do PVL medidos antes e após a administração de medicação ocular hipotensora (p>0,05). Conclusão: A redução da PIO com o uso de medicação ocular hipotensora não altera a medida da espessura da camada de fibras nervosas da retina pela PVL em pacientes com glaucoma ou hipertensão ocular / Abstract: Purpose: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. Methods: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student¿s t Test. Results: The mean IOP was significantly reduced from 26.57 ± 4.23 mmHg to 16.54 ± 2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). Conclusion: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension / Mestrado / Oftalmologia / Mestre em Ciências Médicas
|
82 |
Identificação de genes associados ao glaucoma primário de ângulo aberto / Identification of genes associated with primary open angle glaucomaSantos, Bibiana Amelia Cosim dos, 1985- 23 August 2018 (has links)
Orientadores: José Paulo Cabral de Vasconcellos, Mônica Barbosa de Melo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-23T22:51:05Z (GMT). No. of bitstreams: 1
Santos_BibianaAmeliaCosimdos_M.pdf: 2658658 bytes, checksum: ff5d14370ccba56de1fdd33e8d363ac9 (MD5)
Previous issue date: 2012 / Resumo: O glaucoma primário de ângulo aberto (GPAA) é uma doença neurodegenerativa. Suas características clínicas incluem lesão progressiva do disco óptico com perda de campo visual correspondente. Vários fatores de risco estão associados para sua instalação e desenvolvimento¸ o principal é o aumento da pressão intra-ocular (PIO). Apesar de ser uma doença de herança complexa, foi possível, através da biologia molecular, identificar quatro genes associados a esta forma de glaucoma por meio de estudos de ligação em famílias com esta afecção. O primeiro foi o gene MYOC, descrito em 1997, seguido pelos genes OPTN, WDR36 e NTF4, identificados em 2002, 2005 e 2009, respectivamente. Existem outros 14 loci já descritos em famílias com GPAA com padrão de herança autossômico dominante, cujos genes associados ao glaucoma não foram ainda identificados. Desta forma, através de marcadores do tipo microssatélites - escolhidos a partir do mapa genético humano Généthon serão avaliados os loci candidatos (GLC1A e GLC1J - GLC1N) associados ao glaucoma primário de ângulo aberto em duas famílias informativas portadoras de GPAA. Simultaneamente, será realizada a análise de ligação nestas mesmas famílias por meio de lâminas ou microarrrays de single nucleotide polymorphisms (SNPs) utilizando-se o GeneChip® Mapping 10K 2.0. Na primeira abordagem por meio de microssatélites foram avaliados 33 indivíduos da família 1 e 18 indivíduos da família 2 enquanto que na análise por meio das lâminas de SNPs foram investigados 19 membros da família 1 e 11 membros da família 2. Não houve ligação dos loci investigados: GLC1A, GLC1J - GLC1N em ambas as famílias com o GPAA. Entretanto, na análise de ligação por meio de lâminas de SNPs sugeriu possíveis regiões candidatas associadas ao GPAA (lod score maior do que 2) nos cromossomos 5q31.2 - 31.3 e 2p22.3 - 23.1 / Abstract: Primary open-angle glaucoma is a neurodegenerative disease. Clinical features include progressive damage of the optic disc with corresponding visual field loss. Several risk factors are associated with installation and development, the main is a increased of intraocular pressure (IOP). Although a disease of complex inheritance, it was possible, through molecular biology, identify four genes associated with this form of glaucoma through linkage studies in families with this disease. The first was the MYOC gene, described in 1997, followed by the OPTN genes, WDR36 and NTF4, identified in 2002, 2005 and 2009, respectively. There are 14 other loci already described in POAG families with autosomal dominant, whose genes associated with glaucoma have not yet been identified. Thus, through microsatellite markers - chosen from the human genetic map Généthon will evaluate candidate loci (GLC1A and GLC1J - GLC1N) associated with primary open-angle glaucoma in two informative families carriers from POAG. Simultaneously, will be performed a linkage analysis in these same families through "microarrrays" of "single nucleotide polymorphisms" (SNPs) using the GeneChip Mapping 10K 2.0 ®. In the first approach through microsatellites were evaluated 33 individuals of Family 1 and 18 individuals of Family 2 while the analysis through SNPs were investigated in 19 member of family 1 and 11 members of family 2. There was no linkage of investigated loci: GLC1A, GLC1J - GLC1N in both families with POAG. However, in linkage analysis through SNPs suggested possible candidate regions associated with POAG (lod score greater than two) in the chromosome 5q31.2 - 2p22.3 and 31.3 - 23.1 / Mestrado / Ciencias Basicas / Mestra em Clínica Médica
|
83 |
Goldmann tonometer error correcting prism: clinical evaluationMcCafferty, Sean, Lim, Garrett, Duncan, William, Enikov, Eniko, Schwiegerling, Jim, Levine, Jason, Kew, Corin 05 1900 (has links)
Purpose: Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics. Methods: A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms. The IOP measurement differences between the CATS and Goldmann prisms were correlated to corneal thickness, hysteresis, and curvature. Results: The CATS tonometer prism in correcting for Goldmann central corneal thickness (CCT) error demonstrated a reduction to <+/- 2 mmHg in 97% of a standard CCT population. This compares to only 54% with CCT error <+/- 2 mmHg using the Goldmann prism. Equal reductions of similar to 50% in errors due to corneal rigidity and curvature were also demonstrated. Conclusion: The results validate the CATS prism's improved accuracy and expected reduced sensitivity to Goldmann errors without IOP bias as predicted by mathematical modeling. The CATS replacement for the Goldmann prism does not change Goldmann measurement technique or interpretation.
|
84 |
Applications des ultrasons focalisés de haute intensité au traitement du glaucome / High intensity focused ultrasound for the treatment of glaucomaAptel, Florent 08 December 2011 (has links)
Le glaucome est une pathologie fréquente principalement due à une élévation de la pression intraoculaire. La pression intraoculaire est le fruit d’un équilibre entre la production du liquide qui remplit la portion antérieure de l’œil - l’humeur aqueuse - et son élimination. Les traitements du glaucome peuvent donc agir selon deux mécanismes : la réduction de la production d’humeur aqueuse par la destruction partielle ou l’inhibition pharmacologique du corps ciliaire, structure responsable de la production de l’humeur aqueuse, ou la facilitation de l’évacuation de l’humeur aqueuse en dehors de l’oeil. De nombreuses méthodes physiques peuvent être utilisées pour détruire le corps ciliaire : lasers, cryothérapie, micro-ondes, etc. Néanmoins, toutes ces méthodes ont deux inconvénients majeurs qui limitent leur utilisation : elles sont peu sélectives de l’organe à traiter, entraînant souvent des dommages des structures adjacentes, et elles présentent une relation effet-dose très inconstante, empêchant de prévoir avec précision l’effet du traitement. L’objectif de ce travail de thèse est le développement d’un dispositif ultrasonore de coagulation du corps ciliaire circulaire, comprenant 6 transducteurs piézoélectriques en forme de segments de cylindre, et générant 6 lésions segmentaires s’inscrivant dans un anneau de diamètre similaire à celui formé par le corps ciliaire. Les expérimentations animales ont montré une nécrose de coagulation sélective des zones du corps ciliaire traitées par le dispositif. Le premier essai clinique a montré que cette méthode était bien tolérée et permettait une réduction importante, prédictible et maintenue dans le temps de la pression intraoculaire / Glaucoma is a common disease mainly due to an increase of the pressure inside the eye. Intraocular pressure is the result of a balance between the production of liquid that fills the anterior part of eye - aqueous humor - and its elimination. All treatments for glaucoma aim to reduce the intraocular pressure and can therefore have two mechanisms of action: reducing aqueous humor production by the partial destruction or medical inhibition of the ciliary body - anatomical structure responsible for the production of aqueous humor - or facilitating the evacuation of aqueous humor out of the eye. Several physical methods can be used to destroy the ciliary body: laser, cryotherapy, microwave, etc. However, all these methods have two major drawbacks limiting their use: they are non-selective of the organ to be treated, often resulting in damage to the adjacent structures, and they have an unpredictable dose-effect relationship, preventing to accurately predict the treatment effect. The objective of this thesis is the development of a circular ultrasonic device incorporating six transducers producing high-intensity focused ultrasound for a selective coagulation of the ciliary body. A circular device with 6 piezoelectric transducers having a geometry of a segment of a cylinder was used to generate six segmental lesions entering in a ring of diameter similar to that formed by the ciliary body. Animal experiments have shown a selective coagulation necrosis of the treated ciliary body. The first clinical trial in humans showed that this method was well tolerated and allowed a significant, predictable and sustained reduction of the intraocular pressure
|
85 |
Estudo sobre a deformação da córnea utilizando o sistema de tonometria de não contato integrado a uma câmera de Scheimpflug em olhos saudáveis / Evaluation of corneal deformation analyzed with non-contact tonometer system integrated with an ultra-high-speed (UHS) Scheimpflug camera in healthy eyesBruno de Freitas Valbon 23 September 2016 (has links)
OBJETIVOS: 1) Avaliar os parâmetros de biomecânica ocular provenientes do Corvis ST (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) obtidos de olhos saudáveis de uma população de pacientes brasileiros. 2) Correlacionar os parâmetros derivados do Corvis ST com a idade de pacientes jovens saudáveis. 3) Verificar se as técnicas de facoemulsificação (FC) e do laser de femtosegundo (LFS), empregadas na correção cirúrgica de catatara, influenciam os parâmetros de biomecânica ocular provenientes do Corvis ST. 4) Analisar as alterações da deformação da córnea observadas em um caso de ectasia pós LASIK com flap espesso. MÉTODOS: 1) Estudo clínico transversal conduzido em 90 pacientes (90 olhos saudáveis). Foram avaliados 11 parâmetros derivados do sistema de tonometria de não contato integrado com a câmera ultrarrápida de Scheimpflug (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany), a saber: deformidade de amplitude (DA); pressão intraocular; 1st A time; tempo de concavidade máxima; 2nd A time; 1st A Length (tempo da primeira aplanação); 2nd A Length (tempo da segunda aplanação); raio de curvatura de maior alcance; raio de curvatura normal; velocidade de entrada (Vin) e de saída (Vout). Estes parâmetros foram correlacionados com a espessura central corneana mensurada pela Tomografia de Córnea e Segmento Anterior (Pentacam® - Oculus, Wetzlar, Germany). 2) Estudo clínico observacional, retrospectivo, conduzido em 89 pacientes (89 olhos saudáveis). Os parâmetros derivados do Corvis ST foram correlacionados com a idade dos pacientes. 3) Estudo clínico prospectivo, envolvendo 151 olhos de 127 pacientes com diagnóstico de catarata nuclear. Setenta e cinco olhos de 65 pacientes foram submetidos à técnica do laser de femtosegundo (AlconLenSx, Aliso Viejo, USA) e 76 olhos de 62 pacientes à facoemulsificação convencional (Alcon Infinit, Fort Worth, USA). Foram avaliados os 11 parâmetros de biomecânica ocular derivados do Corvis ST antes (Pré) e após as cirurgias de catarata (D1, primeiro dia de pósoperatório). A densitometria do cristalino (scattering) foi realizada pelo PNS (Pentacam Nucleus Staging). 4) Avaliação com tomografia de coerência óptica de espessura dos flaps corneanos pós Lasik e análise dos parâmetros biomecânicos provenientes do Corvis ST em uma córnea com ectasia pós Lasik. RESULTADOS: 1) A média de idade dos pacientes foi de 35,80 ± 12,83 anos. A média do equivalente esférico foi de -3,29 ± 3,69 dioptrias. A média da espessura central corneana foi de 547,50 ± 32,00 ?m Os valores dos 11 parâmetros biomecânicos obtidos de olhos saudáveis, foram os seguintes: deformidade de amplitude 1,05 ± 0,08 mm; tempo de concavidade máxima 18,38 ± 0,93 ms; pressão intraocular 16,43 ± 2,15 mmHg; tempo da primeira aplanação (1st A time) 8,32 ± 0,33 ms; tempo da segunda aplanação 23,80 ± 0,44 ms; raio de curvatura de maior alcance 11,09 ± 2,06 mm; raio de curvatura normal 7,59 ± 0,67 mm; tempo da primeira aplanação (1st A Length) 2,07 ± 0,38 mm; tempo da segunda aplanação (2nd A Length) 2,37 ± 0,47 mm; velocidade de entrada (Vin) 0,21 ± 0,05 m/s e velocidade de saída (Vout) -0,33 ± 0,07 m/s. 2) A média de idade dos pacientes foi de 27,50 ± 6,30 anos. O tempo de concavidade máxima alcançada da córnea (HC-time) foi o único dos 11 parâmetros que apresentou correlação significativa com a idade (p=0,04, rs=0,18). 3) A média de idade dos pacientes dos grupos LFS (laser de femtosegundo) e FC (facoemulsificação convencional) foram, respectivamente, 67,6 ± 9,9 anos e 68,4 ± 11,8 anos. No grupo LFS, 9 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1; e no grupo FC, 7 dos 11 parâmetros foram estatisticamente significativos entre o Pré e D1. Entre os 11 parâmetros biomecânicos avaliados, somente o tempo de concavidade máxima da córnea (HC-time) foi significativamente diferente entre os dois grupos em D1 (p=0,0387). 4) Paciente do sexo feminino, 45 anos, submetida à Lasik em ambos os olhos. Com a utilização da tomografia de coerência óptica (OCT Rtvue, OptoVue, Fremont, CA,USA) foram identificados: um flap com espessura central de 392 ?m no OD e dois cortes, sendo um flap incompleto profundo e o outro mais fino superiormente, no OE. Os parâmetros derivados do Corvis ST como a deformidade de amplitude são diferentes em ambos os olhos. CONCLUSÕES: 1) Os valores de 8 dos 11 parâmetros derivados do Corvis ST foram influenciados pela espessura central da córnea, porém esta influência foi baixa. 2) Em olhos saudáveis de pacientes jovens foi obtida correlação significativa entre a idade e o tempo de concavidade máxima, que é o tempo do início de aplanação até a concavidade máxima alcançada da córnea. 3) O laser de femtosegundo para cirurgia de catarata e a técnica de facoemulsificação convencional induziram alterações nas propriedades biomecânicas da córnea no D1. Dos 11 parâmetros biomecânicos estudados apenas o tempo de concavidade máxima da córnea apresentou diferença significativa entre os grupos (LFS e FC) no D1. 4) A ectasia unilateral após LASIK pode ocorrer devido a flap espesso com falência biomecânica da córnea / PURPOSE: 1) To evaluate ocular biomechanical metrics given by the CorVis ST (Oculus, Inc., Berlin, Germany) in a population of healthy Brazilian patients. 2) To correlate parameters derived from corneal deformation resulting from non-contact tonometry integrated with an ultra-high-speed (UHS) Scheimpflug camera (Oculus Corvis ST, Scheimpflug Technology; Wetzlar, Germany) with age in normal eyes from young patients. 3) To evaluate the changes of corneal biomechanical after femtosecond laser - assisted cataract (FS) and to compare the parameters derived by Corvis ST between standard phacoemulsification (SP) and femtosecond laser - assisted in cataract surgery. 4) To report a case of post-LASIK corneal ectasia due to a thick flap, while the contralateral eye did not develop ectasia after an incomplete deep flap cut, followed by a thinner flap Lasik procedure. METHODS: 1) An observational and cross-sectional study involving 1 eye randomly selected from 90 healthy patients. Studied parameters (including deformation amplitude, first applanation time, highest concavity time, second applanation time, first applanation length, second applanation length, curvature radius highest concavity, curvature radius normal, velocity in, and velocity out) derived from the CorVis ST were correlated to central corneal thickness from the Pentacam (Oculus, Inc.). Differences between data on the basis of gender were evaluated. 2) Observational, retrospective study involving one eye randomly selected from study participants, totaling 89 healthy eyes. The Scheimpflug images were taken with an ultra-high-speed camera during each measurement by the Corvis ST. The deformation amplitude (DA) and other parameters (e.g., pachy apex, intraocular pressure, 1st A time, highest concavity-time, 2nd A time, 1st A Length, 2nd A Length, Wing-Dist, curvature radius highest concavity, curvature radius normal, Vin, Vout) measured by the corvis ST were correlated with age. 3) Prospective study: 151 eyes of 127 patients were underwent cataract surgery. 75 eyes of 65 patients were with femtosecond laser-assisted (FS)(Alcon Len Sx, Aliso Viejo,USA) and 76 eyes of 62 patients with standard phacoemulsification (SP) (Alcon Infinit, FortWorth, USA). 4) Case Report. RESULTS: 1) About the first study: Mean patient age was 35.80 ± 12.83 years (range: 21.07 to 78.84 years). Mean central corneal thickness was 547.50 ± 32.00 ?m (range: 490 to 647 ?m) and mean spherical equivalent refraction was -3.29 ± 3.69 diopters (range: -9.50 to +10.37 diopters). Mean deformation amplitude was 1.05 ± 0.08 mm (range: 0.91 to 1.26 mm). Highest concavity time was 18.38 ± 0.93 ms (range: 16.95 to 21.07 ms). Intraocular pressure was 16.43 ± 2.15 mm Hg (range: 11.50 to 21.0 mm Hg). First applanation time was 8.32 ± 0.33 ms (range: 7.53 to 9.12 ms) and second applanation time was 23.80 ± 0.44 ms (range: 22.76 to 24.95 ms). First applanation length (max) was 2.07 ± 0.38 mm (range: 1.20 to 3.10 mm) and second applanation length (max) was 2.37 ± 0.47 mm (range: 1.33 to 4.12 mm). Curvature radius highest concavity was 11.09 ± 2.06 mm (range: 7.58 to 15.98 mm) and curvature radius normal was 7.59 ± 0.67 mm (range: 6.82 to 11.02 mm). Velocity in was 0.21 ± 0.05 m/s (range: 0.16 to 0.72 m/s) and velocity out was -0.33 ± 0.07 m/s (range: - 0.72 to -0.20 m/s). Studied parameters were not associated with gender. 2) Mean patient age was 27.50 ± 6.30 years. The highest concavity-time was the only studied parameter statistically significantly correlated to age (i.e., p=0.04, rs=0.18). 3) In relation the surgery of cataract: In group of FS, 9 of 11 parameters derived from Corvis ST were statistically significant (ss). In group of SP, 7 of 11 parameters derived from Corvis ST were ss. Only the HC - time was statistically significant between two groups (FS;SP) with p = 0.0387. 4) Corneal OCT identified a deep meniscos-shaped Lasik flap, with a central thickness of a 392 ?m in the right eye, and a incomplete deep peripheral cut in the left eye with a thinner meniscos-shaped LASIK flap. CONCLUSIONS: 1) Eight of 11 ocular biomechanical metrics given by the CorVis ST were associated with central corneal thickness, but the influence of central corneal thickness on these measurements was low. 2) In healthy eyes, age and pressure or biomechanics as derived from the Corvis ST parameters were not associated with exception to highestconcavity-time, i.e., the time from starting until the highest concavity is reached. 3) The use of the femtosecond laser- assisted system for cataract surgery and standard phacoemulsification induzed changes of biomechanical properties of the cornea by Corvis ST. Only 1 of 11 parameters studied was different statistically in two groups. 4) Unilateral ectasia after LASIK may occur due to a thick flap which leads to biomechanical failure of the cornea
|
86 |
Risk of elevated intraocular pressure after ranibizumab injection in patients with neovascular age-related macular degenerationMoghadaszadeh, Solmaz 01 1900 (has links)
Objectif : Nous avons voulu évaluer le risque d’élévation chronique de la pression intraoculaire suite à des injections de ranibizumab dans le traitement de la dégénérescence maculaire liée à l’âge de type néovasculaire. Méthode : Nous avons réalisé une étude rétrospective sur 161 patients ayant reçu des injections de ranibizumab dans un œil seulement. Les critères excluent les patients ayant du glaucome non contrôlé au départ (PIO>21mmHg) et ceux qui ont eu moins de 9 semaines de suivi après l’injection. L’élévation de la PIO est définie comme une augmentation de >5mmHg sur deux visites consécutives. Résultats : Nous n’avons pas déterminé de différence de pourcentage entre les yeux ayant reçus des injections pour lesquels il y a une élévation de la PIO (n=8.5%), comparé au pourcentage de yeux n’ayant pas reçus d’injections pour lesquels il y a une élévation de la PIO (n=9.6%). Cependant, un plus grand nombre d’injections d’anti-VEGF est associé avec une élévation chronique de la PIO (P=0.032). D’autres facteurs de risque de l’élévation chronique de la PIO sont le diabète, une PIO faible au départ, et une PIO maximale plus élevée (P<0.05). Conclusion : Un plus grand nombre d’injections semble augmenter le risque d’élévation de la PIO. Les patients atteints de diabète semblent être plus à risque et nécessiter une étroite surveillance. / Purpose: Conflicting evidence exists about the risk of chronic elevation of intraocular pressure (IOP) after ranibizumab injections for neovascular age-related macular degeneration. The goal of this study is to evaluate this risk.
Methods: A retrospective cohort study of 161 people. Inclusion criteria included receiving at least three ranibizumab injections in one eye only and having at least 9 weeks of follow-up. Exclusion criteria included the presence of uncontrolled glaucoma or ocular hypertension at baseline (IOP>=21mmHg). Chronic IOP elevation was defined as an increase >5mmHg of IOP on at least 2 consecutive visits.
Results: There was no difference in the percentage of injected eyes that experienced a chronic IOP increase (n=8, 5%) compared to the percentage of uninjected eyes that experienced an IOP increase (n=9, 6%). However, a greater number of anti-VEGF injections was associated with chronic IOP elevation (P=0.032). Other risk factors for chronic IOP elevation included diabetes, a lower baseline IOP, and a higher maximum IOP (P<0.05).
Conclusions: A greater number of injections appears to increase the risk of chronic IOP elevation. Also, diabetics appear to be more at risk and may need more careful follow-up or preventive pharmacological treatment.
|
87 |
Reprodutibilidade do teste de sobrecarga hídrica em portadores de glaucoma de ângulo aberto sob tratamento clínico / Reproducibility of the water drinking test in treated glaucomatous patientsBabic, Mirko 28 April 2017 (has links)
OBJETIVO: avaliar a reprodutibilidade dos picos de pressão intraocular e a flutuação obtidas durante o teste de sobrecarga hídrica em pacientes glaucomatosos tratados com um longo intervalo de seguimento. MÉTODOS: análise retrospectiva de 34 pacientes portadores de glaucoma primário de ângulo aberto, sob tratamento clínico, atendidos durante o período de uma semana no ambulatório de um dos investigadores (RSJ). Os pacientes foram submetidos ao teste de sobrecarga hídrica, realizado em duas visitas consecutivas, sem alteração do regime terapêutico. O intervalo médio entre os testes foi de 4,85 (intervalo, 3-6) meses. A reprodutibilidade do pico e a flutuação durante o teste de sobrecarga hídrica foram avaliadas utilizando coeficientes de correlação intraclasse. A análise de Bland-Altman foi utilizada para avaliar a concordância entre os picos de pressão intraocular e a flutuação, medidos entre dois testes consecutivos. RESULTADOS: trinta e quatro olhos de 34 pacientes foram estudados. Não houve diferenças significativas nos valores de pressão intraocular basal (média ± desvio-padrão, 11,73 ± 2,36 e 11,61 ± 2,71 mmHg; p = 0,72) e picos (14,55 ± 3,41 e 15,02 ± 3,66 mmHg, respectivamente; p = 0,163) detectados durante o teste de sobrecarga hídrica entre a primeira e a segunda visitas. Também não houve diferença significativa entre os valores médios de flutuação da pressão intraocular (2,82 ± 1,99 e 3,41 ± 2,54 mmHg, respectivamente; p = 0,135). Os picos de pressão intraocular e a flutuação apresentaram coeficientes de correlação intraclasse de 0,85 (p < 0,001) e 0,50 (p < 0,001), respectivamente. CONCLUSÕES: neste estudo, os resultados demonstraram excelente reprodutibilidade dos picos de pressão intraocular durante o teste de sobrecarga hídrica. Entretanto, a flutuação da pressão intraocular não revelou boa reprodutibilidade / OBJECTIVE: To evaluate the reproducibility of intraocular pressure peaks and fluctuation elicited during the water drinking test in treated glaucomatous patients with a long follow-up interval. METHODS: 34 treated primary openangle glaucoma patients evaluated in retrospective cohort study in a tertiary care practice. All patients underwent the water drinking test performed in two consecutive visits without any change in the therapeutic regimen. The mean interval between tests was 4.85 (range, 3-6) months. Reproducibility of peak and fluctuation during the water drinking test was assessed using intraclass correlation coefficients. Bland-Altman analysis was used to assess the agreement of intraocular pressure peaks and fluctuation measured between two consecutive tests. RESULTS: There were no significant differences in baseline intraocular pressure values (mean ± standard deviation, 11.73 + 2.36 and 11.61+2.71 mmHg; p=0.72) and peaks (14.55+3.41 and 15.02 ± 3.66 mmHg, respectively; p=0.163) detected during the water drinking test between the first and second visits. There was also no significant difference between the average intraocular pressure fluctuation values (2.82 ± 1.99 and 3.41 ± 2.54 mmHg, respectively; p=0.135). Intraocular pressure peaks and fluctuation presented intraclass correlation coefficients of 0.85 (p < 0.001) and 0.50 (p < 0.001), respectively. CONCLUSIONS: Our results demonstrate excellent reproducibility of intraocular pressure peaks during the water drinking test. Intraocular pressure fluctuation did not reveal good reproducibility, though
|
88 |
Comparação prospectiva e randomizada entre DisCo Visc e hidroxipropilmetilcelulose 2% durante a facoemulsificação / Prospective randomized comparison of DisCoVisc and 2% hydroxypropylmethilcellulose in phacoemulsificationEspindola, Rodrigo França de 16 October 2015 (has links)
INTRODUÇÃO: Comparar duas soluções viscoelásticas, ácido hialurônico 1,6%/sulfato de condroitina 4% (DisCoVisc®, Alcon Laboratórios, EUA) e hidroxipropilmetilcelulose 2% (HPMC, Ophthalmos, Brasil), com relação ao desempenho durante a facoemulsificação (FACO) e o implante de lente intraocular. MÉTODOS: Foi realizado um ensaio clínico randomizado, envolvendo 78 olhos (39 pacientes) submetidos à FACO bilateral, por um único cirurgião. Os pacientes foram randomizados para receber DisCoVisc ou HPMC no primeiro olho. O olho contralateral foi operado mais tarde recebendo a outra solução viscoelástica em todas as etapas da cirurgia. Examinadores mascarados realizaram as avaliações pré e pósoperatórias (5, 24 e 48 horas; 7 e 14 dias; 3 e 6 meses), incluindo a medida da pressão intraocular (PIO), espessura cornena central (ECC) e acuidade visual corrigida. A densidade endotelial foi realizada no pré-operatório e ao final do seguimento (6 meses). Variáveis intraoperatórias incluíram medidas da quantidade total de solução viscoelástica, tempo de ultrassom durante a FACO e tempo para a retirada completa da solução do olho. RESULTADOS: A densidade endotelial foi estatisticamente superior com DisCoVisc (2.214 ± 372 cel/mm2) do que com HPMC (2.032 ± 460 cel/mm2) ao final do seguimento (p = 0,001). Uma redução média de 7% e de 15%, respectivamente. Não houve diferença estatística entre as soluções viscoelásticas com relação a densidade da catarata (p = 0,363) e o tempo de ultrassom (p = 0,456). O tempo de aspiração da HPMC (0,22 ± 0,09 min) foi significativamente maior que o DisCoVisc (0,17 ± 0,06 min) (p = 0,001) e a quantidade de viscoelástico utilizada foi maior com a HPMC (1,35 ± 0,20 ml) do que com DisCoVisc (0,89 ± 0,11 ml) (p < 0,001). Não houve diferença estatisticamente significativa entre as soluções quanto a ECC e a PIO durante o seguimento. CONCLUSÕES: A densidade endotelial ao final do estudo foi significativamente maior com o uso de DisCoVisc, o que pode representar uma melhor proteção endotelial. Foi necessário uma menor quantidade de DisCoVisc e um tempo de aspiração menor durante a FACO com essa solução viscoelástica / INTRODUCTION: To compare two ophthalmic viscosurgical devices (OVDs), 1.6% hyaluronic acid/4% chondroitin sulfate (DisCoVisc®, Alcon Lab., USA) and 2% hydroxypropylmethylcellulose (HPMC, Ophthalmos, Brazil), in terms of their overall performance during phacoemulsification (PHACO) and intraocular lens implantation. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that underwent PHACO by the same surgeon. Patients were randomly assigned to receive DisCoVisc or HPMC on the first eye. The other eye was treated later and received the other OVD. Masked examiners measured intraocular pressure (IOP), central corneal thickness (CCT) and best-corrected visual acuity. The corneal endothelial cell density was measured at baseline and at 6 months postoperatively. Intraoperative variables include the total amount of the OVD, ultrasound and washout times. RESULTS: Corneal endothelial cell density was significantly higher with DisCoVisc (2.214 ± 372 cell/mm2) than HPMC (2.032 ± 460 cell/mm2) at the end of follow-up (p = 0.001). A mean reduction of 7% and 15%, respectively. There were no statistically significant differences between OVDs in terms of cataract density (p = 0.363) or ultrasound time (p = 0.456). Regarding washout time, it took longer to remove HPMC (0.22 ± 0.09 min) than DisCoVisc (0.17 ± 0.06 min) (p = 0.001), and the amount of viscoelastic material used was greater with HPMC (1.35 ± 0.20 ml) than DisCoVisc (0.89 ± 0.11 ml) (p < 0.001). There were no statistically significant differences between the two OVDs regarding CCT or IOP measurements at any point in time. CONCLUSION: The corneal endothelial cell loss was significantly less with DisCoVisc than HPMC, which can improve corneal endothelium protection. DisCoVisc was easier to remove after IOL implantation and fewer amounts were necessary during PHACO
|
89 |
Avaliação dos efeitos da variabilidade da pressão arterial sistêmica sobre a pressão de perfusão ocular e suas repercussões sobre o estresse oxidativo em retinas de ratos normotensos e hipertensos / Assessment of the effects of the variability of blood pressure on the ocular perfusion pressure and its effects on oxidative stress in normotensive and hypertensive ratsCastro, Emerson Fernandes de Sousa e 21 August 2014 (has links)
Introdução: A hipertensão arterial sistêmica (HAS) é uma doença que pode determinar lesões em diversos órgãos inclusive nos olhos. As doenças vasculares oculares constituem a grande maioria das causas de cegueira na atualidade e a HAS tem contribuição importante nesta estatística. A variabilidade da pressão arterial tem sido implicada na gênese de uma série de lesões de órgãos-alvo. Na tentativa de compreender melhor a patogênese das doenças vasculares oculares testamos a hipótese de que não apenas os efeitos da HAS, mas também a variabilidade da pressão arterial (PA) poderia determinar lesão de órgão-alvo (ocular). Materiais e Métodos: A desnervação sino-aórtica (DSA), um modelo experimental de aumento da variabilidade da pressão arterial foi utilizado nos experimentos. Foram obtidas medidas da pressão intraocular e a partir destas medidas, a pressão de perfusão ocular. Foram analisados marcadores de estresse oxidativo (8-OHdG e nitrotirosina),VEGF e receptores AT1 na retina de animais normotensos e hipertensos com e sem DSA aguda (12 e 24 horas) e crônica (10 semanas). Resultados: Os animais desnervados apresentaram aumento da variabilidade da PA sem modificar a PA basal e redução da sensibilidade do barorreflexo. Houve aumento da modulação simpática vascular e da pressão de perfusão ocular (PPO), nos animais hipertensos, com aumento adicional da PPO nos hipertensos e desnervados crônicos.Observou-seestresse oxidativo retiniano nos animais desnervados agudos e noshipertensos desnervados crônicos, além do aumento da expressão de receptores AT1 da Angiotensina II nos animais hipertensos. Os níveis de VEGF retinianos dos animais desnervados crônicos, apresentaram comportamento inverso aos níveis de Caspase-3. Conclusão: Tais resultados indicam que só a HAS, mas também a variabilidade da PA podem determinar variações na pressão de perfusão ocular, assim como também podem induzir dano oxidativo às células retinianas. Além disso, pode-se sugerir efeito neuroprotetor retiniano do VEGF / Introduction: High blood pressure (HBP) is a disease that can determine lesions in many organs including the eyes. The ocular vascular diseases constitute the vast majority of causes of blindness and hypertension has important contribution in this statistic. Blood pressure variability has been implicated in the genesis of a series of end-organ damage. In an attempt to better understand the pathogenesis of ocular vascular diseases, we hypothesized that not only the effects of hypertension, but also the variability of blood pressure (BPV) could determine target end-organ damage (ocular). Materials and Methods: Sino-aortic denervation (SAD), an experimental model of increased blood pressure variability was used in the experiments. The intraocular pressure measurements were performed and from these measurements the ocular perfusion pressure was estimated. Oxidative stress markers (8-OHdG and nitrotyrosine), VEGF and AT1 receptor in rat retinas were analyzed inacute and chronic hypertensive and normotensiveSAD rats and in controls. Results: Denervated animals showed increased BP variability without altering the basal BP, while presenting reduced baroreflex sensitivity.There was an increase in sympatheticvascular modulation and in OPP,in hypertensive animals, that was additionally in chronic denervated hypertensive animals.Acute denervated and chronic hypertensive denervated animals showed retinal oxidative stress as well as hypertensive animals presented increased expression of AT1 receptors of angiotensin II. The levels of retinal VEGF of chronically denervated animals showed inverse behavior of levels of Caspase-3 Conclusion: These results suggest that, apart from the arterial hypertension, BP variability not only determines changes in ocular perfusion pressure, but also induces oxidative damage to retinal cells. Furthermore, one can suggest retinal neuroprotective effect of VEGF
|
90 |
Reprodutibilidade do teste de sobrecarga hídrica em portadores de glaucoma de ângulo aberto sob tratamento clínico / Reproducibility of the water drinking test in treated glaucomatous patientsMirko Babic 28 April 2017 (has links)
OBJETIVO: avaliar a reprodutibilidade dos picos de pressão intraocular e a flutuação obtidas durante o teste de sobrecarga hídrica em pacientes glaucomatosos tratados com um longo intervalo de seguimento. MÉTODOS: análise retrospectiva de 34 pacientes portadores de glaucoma primário de ângulo aberto, sob tratamento clínico, atendidos durante o período de uma semana no ambulatório de um dos investigadores (RSJ). Os pacientes foram submetidos ao teste de sobrecarga hídrica, realizado em duas visitas consecutivas, sem alteração do regime terapêutico. O intervalo médio entre os testes foi de 4,85 (intervalo, 3-6) meses. A reprodutibilidade do pico e a flutuação durante o teste de sobrecarga hídrica foram avaliadas utilizando coeficientes de correlação intraclasse. A análise de Bland-Altman foi utilizada para avaliar a concordância entre os picos de pressão intraocular e a flutuação, medidos entre dois testes consecutivos. RESULTADOS: trinta e quatro olhos de 34 pacientes foram estudados. Não houve diferenças significativas nos valores de pressão intraocular basal (média ± desvio-padrão, 11,73 ± 2,36 e 11,61 ± 2,71 mmHg; p = 0,72) e picos (14,55 ± 3,41 e 15,02 ± 3,66 mmHg, respectivamente; p = 0,163) detectados durante o teste de sobrecarga hídrica entre a primeira e a segunda visitas. Também não houve diferença significativa entre os valores médios de flutuação da pressão intraocular (2,82 ± 1,99 e 3,41 ± 2,54 mmHg, respectivamente; p = 0,135). Os picos de pressão intraocular e a flutuação apresentaram coeficientes de correlação intraclasse de 0,85 (p < 0,001) e 0,50 (p < 0,001), respectivamente. CONCLUSÕES: neste estudo, os resultados demonstraram excelente reprodutibilidade dos picos de pressão intraocular durante o teste de sobrecarga hídrica. Entretanto, a flutuação da pressão intraocular não revelou boa reprodutibilidade / OBJECTIVE: To evaluate the reproducibility of intraocular pressure peaks and fluctuation elicited during the water drinking test in treated glaucomatous patients with a long follow-up interval. METHODS: 34 treated primary openangle glaucoma patients evaluated in retrospective cohort study in a tertiary care practice. All patients underwent the water drinking test performed in two consecutive visits without any change in the therapeutic regimen. The mean interval between tests was 4.85 (range, 3-6) months. Reproducibility of peak and fluctuation during the water drinking test was assessed using intraclass correlation coefficients. Bland-Altman analysis was used to assess the agreement of intraocular pressure peaks and fluctuation measured between two consecutive tests. RESULTS: There were no significant differences in baseline intraocular pressure values (mean ± standard deviation, 11.73 + 2.36 and 11.61+2.71 mmHg; p=0.72) and peaks (14.55+3.41 and 15.02 ± 3.66 mmHg, respectively; p=0.163) detected during the water drinking test between the first and second visits. There was also no significant difference between the average intraocular pressure fluctuation values (2.82 ± 1.99 and 3.41 ± 2.54 mmHg, respectively; p=0.135). Intraocular pressure peaks and fluctuation presented intraclass correlation coefficients of 0.85 (p < 0.001) and 0.50 (p < 0.001), respectively. CONCLUSIONS: Our results demonstrate excellent reproducibility of intraocular pressure peaks during the water drinking test. Intraocular pressure fluctuation did not reveal good reproducibility, though
|
Page generated in 0.1038 seconds