• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 223
  • 50
  • 19
  • 1
  • Tagged with
  • 291
  • 128
  • 73
  • 70
  • 57
  • 56
  • 42
  • 37
  • 32
  • 31
  • 28
  • 26
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Mesure et caractérisation du transfert de chaleur dans les colonnes à bulles type slurry / Measure and characterisation of heat transfer in slurry bubble column reactors

Béliard, Pierre-Emmanuel 14 January 2011 (has links)
Ce travail concerne la mesure et la caractérisation du transfert thermique à la paroi externe d’un faisceau de tube de refroidissement inséré dans des colonnes à bulles type « slurry ». La valeur du coefficient de transfert de chaleur est estimée à partir des équations de la chaleur. Une colonne de 0,15 m de diamètre et de 4 m de haut, équipée de deux tubes en U (3 cm de diamètre externe), a été utilisée pour mettre au point la métrologie nécessaire. L’eau a servi de fluide de refroidissement. Le mélange diphasique air-huile Syltherm XLT®, puis le mélange triphasique air-huile Syltherm XLT®-microbilles d’alumine poreuses (dS ~ 80 μm), ont servi de fluides modèles. L’incertitude de nos mesures a été estimée à environ 8 %. En système diphasique, les variations du coefficient de transfert de chaleur avec la vitesse superficielle du gaz ont pu être corrélées par une loi semblable à celle de Deckwer (1980). Cependant, la valeur de la constante de corrélation semble dépendre de l’orientation du faisceau de tubes par rapport à l’axe de la colonne. Un tel comportement n’a jamais été rapporté dans la littérature. L’écart du faisceau à un faisceau idéal (i.e. parfaitement droit et symétrique) peut être un paramètre crucial pour le transfert de chaleur. En système triphasique, la valeur du coefficient ne varie pas de façon significative jusqu’à une concentration massique d’environ 18,8 %, avant de diminuer d’environ 10 % pour une concentration massique de 21,3 %. Ce résultat est surprenant. Les variations rapportées dans la littérature sont en effet souvent contradictoires, mais toujours continues dans la gamme de concentrations testée. La métrologie mise au point a été implantée dans une colonne de 1 m de diamètre et de 5 m de haut, équipée de 24 tubes en U (6 cm de diamètre externe). Celle-ci est jugée représentative d’un réacteur pour le procédé Fischer-Tropsch. Les premiers résultats indiquent que la caractérisation thermique de l’installation sera plus délicate que pour la petite colonne / This work investigates the measure and characterisation of heat transfer in slurry bubble column reactors equipped with a bundle of cooling tubes. The value of the shell-tube heat transfer coefficient is estimated at thermal steady-state regime using heat transfer equations. A 15 cm in diameter, 4 m high bubble column, equipped with a two U-tubes (3 cm O.D.) bundle has been used to assess the metrology selected. The cooling fluid was water. Air-Syltherm XLT® heat transfer fluid and air-Syltherm XLT® heat transfer fluid-porous alumina particles (dS ~ 80 μm) were successively used as shell fluids. The uncertainty of our measures has been estimated to be around 8 %. The variations of the shell-tube heat transfer coefficient with superficial gas velocity can be modelled using the well-known correlation by Deckwer (1980). However, a smaller constant value than indicated by Deckwer et al. (1980) was obtained and it was found to be dependent upon the orientation of the tube bundle relatively to the column axis. This has never been reported in the literature and implies that any difference relatively to the ideal tube bundle – perfectly straight and symmetric – might be critical for heat transfer. Addition of solid particles has little effect on heat transfer for solid concentrations below 18.8 %w/w. A further increase up to 21.3 %w/w induced a 10 % decrease of the value of the shell-tube heat transfer coefficient. This was surprising, as existing literature results display continuous variations of the heat transfer coefficient values in the range of solid concentrations tested, even though trends of variation could be opposite. The assessed metrology was implemented into a 1 m in diameter, 5 m high bubble column equipped with a 24 U-tubes (6 cm O.D.) bundle. This pilot plant was considered to be large enough to mock up a slurry bubble column reactor for the Fischer-Tropsch process. First results indicate that thermal characterisation will be more complex than for the smaller diameter column
132

Nouvelle métrologie large bande à grande dynamique pour la mesure des flux transmis, réfléchis et diffusés par des filtres optiques à hautes performances / Innovative broad-spectrum width and wide dynamic range instrument for measurements of reflected, transmitted and scattered flux by complex optical filters

Liukaityte, Simona 17 November 2016 (has links)
De nombreux efforts fournis sur l’avancement de la technologie de dépôt afin de répondre au besoin des utilisateurs des filtres interférentiels ont donné la naissance à la nouvelle génération des composants optiques. Les progrès techniques permettent de fabriquer les filtres avec la structure particulièrement complexe et atteindre les performances spectrales remarquables, mais aussi soulèvent de nouveaux problèmes au niveau de la diffusion. Les indicatrices de diffusion de ces filtres présentent les variations extrêmement rapides en fonction de l’angle de reprise et de la longueur d’onde, ce qui amoindrit sérieusement les performances des composants. Il est donc d’essentiel d’être capable de caractériser la diffusion lumineuse angulairement et spectralement résolue. L’objectif de cette thèse a alors été de développer l’outil expérimental, déduit pour la métrologie fine de la réponse spectrale et de la diffusion lumineuse. Le travail réalisé a donné naissance au banc SALSA (pour Spectral and Angular Light Scattering characterization Apparatus), un nouveau diffusomètre spectralement et angulairement résolu. Grâce au banc SALSA nous pouvons effectuer les mesures de diffusion sur large gamme spectrale [400 nm -1000 nm] avec la dynamique de 8 décades et la précision meilleure que 1%. Par ailleurs, le banc peut être utilisé pour la mesure de la transmission avec la dynamique de 12 décades, ce qui est performance unique sur l’échèle mondiale. / Due to market demand and technical progresses, a new generation of optical components requires much more sophisticated structures with a great number of layers. These complex structures enable to achieve severe optical performances but, at the same time, enhance light scattering processes. For these reasons, it is essential to develop a metrological tool which provides an accurate quantification of the spectral and angular behavior of scattering losses, with sufficient angular and spectral resolution. In order to face this issue, new investigations were performed during this PhD thesis and led to the development of the new scatterometer SALSA (Spectral and Angular Light Scattering characterization Apparatus). The use of both a broad-band source and a tunable filter allows to accurately select the illumination wavelength and the spectral bandwidth on the whole spectral range of CCD detectivity. Set-up SALSA allows us to perform the measurements of scattering losses on a wide spectral range (400-1000 nm), with high dynamics (>8 decades), high accuracy and low detectivity (a few 10-8 sr-1). Moreover, with set-up SALSA we are able to measure the transmission of interferential filters on the same spectral range, with high accuracy (1%) and a high dynamic (>10 decades, which is a unique performance).
133

Quantum sensing with Rydberg Schrödinger cat states / Sensibilité quantique avec des états chats de Rydberg Schrödinger

Dietsche, Eva-Katharina 14 September 2017 (has links)
Les atomes de Rydberg sont des états très excités, dans lesquels un électron est placé sur une orbite éloignée du noyau. Leur grand dipôle électrique les rend très sensibles à leur environnement électromagnétique. En utilisant des champs microondes et radiofréquences, nous préparons des états quantiques non-classiques spécialement conçus pour exploiter au mieux cette sensibilité et mesurer des champs électriques et magnétiques avec une grande précision. Dans la première partie, nous préparons des états chats de Schrödinger, superpositions d'orbitales de polarisabilités très différentes, qui nous permettent de mesurer de petites variations du champ électrique statique avec une sensibilité bien supérieure à la limite quantique standard et proche de la limite Heisenberg fondamentale. Nous atteignons une sensibilité par atome de 30mV/m pour un temps d'interrogation de 200ns, faisant de notre système l'un des électromètres les plus sensibles à ce jour. Nous implémentons ensuite des manipulations plus complexes de l'atome. Grâce à une technique d'écho de spin qui exploite la richesse de la multiplicité Rydberg, nous mesurons les corrélations temporelles du champ électrique avec une bande passante de l'ordre du MHz. Dans la partie finale, nous préparons une superposition quantique de deux états circulaires de nombres quantiques magnétiques opposés. Cet état très non-classique correspond à un électron tournant à la fois dans des directions opposées sur la même orbite. La grande différence de moment magnétique entre les deux composantes de la superposition, de l'ordre de 100muB, ouvre la voie à la mesure de petites variations du champ magnétique avec une grande bande passante. / Rydberg atoms are highly excited states, in which the electron is orbiting far from the nucleus. Their large electric dipole makes them very sensitive to their electromagnetic environment. Using a combination of microwave and radio-frequency fields, we engineer non-classical quantum states specifically designed to exploit at best this sensitivity for electric and magnetic field metrology. In the first part, we prepare non-classical states, similar to Schrödinger cat states, superpositions of two orbitals with very different polarizabilities, that allow us to measure small variations of the static electric field with a sensitivity well beyond the standard quantum limit and close to the fundamental Heisenberg limit. We reach a single atom sensitivity of 30mV/m for a 200ns interrogation time. It makes our system one of the most sensitive electrometers to date. We then implement more complex manipulations of the atom. Using a spin-echo technique taking advantage of the full extent of the Rydberg manifold, we perform a correlation function measurement of the electric field with a MHz bandwidth.In the final part, we prepare a quantum superposition of two circular states with opposite magnetic quantum numbers. It corresponds to an electron rotating at the same time in opposite directions on the same orbit, a rather non-classical situation. The huge difference of magnetic moment between the two components of the superposition, in the order of 100muB, opens the way to the measurement of small variations of the magnetic field with a high bandwidth.
134

Développement de méthodes instrumentales en vue de l'étude Lagrangienne de l'évaporation dans une turbulence homogène isotrope / Digital holography measurements of Lagrangian trajectories and diameters of evaporating droplets in homogeneous and isotropic turbulence

Chareyron, Delphine 16 December 2009 (has links)
Cette thèse est centrée sur le développement d’outils expérimentaux permettant de mieux caractériser l’étude du couplage entre l’évaporation de gouttelettes et un écoulement turbulent gazeux environnant. Dans notre étude on cherche à se placer dans un régime de couplage fort entre les gouttelettes évaporantes et la turbulence. Dans ce régime peu renseigné dans la littérature, les gouttelettes se trouvent dans un régime intermédiaire entre le régime de traceur et le régime inertiel. Dans un premier temps nous présentons un dispositif expérimental capable de générer une turbulence homogène isotrope avec de fortes fluctuations de vitesse, ainsi que la réalisation de l’injection de gouttelettes initialement monodisperses. Puis, l’instrumentation Lagrangienne développée (en collaboration avec le laboratoire Hubert Curien de St Etienne) : l’holographie numérique en ligne, est ensuite testée et validée pour un fluide non évaporant. Une méthode de tracking des gouttelettes a été mise au point afin de reconstruire les trajectoires des gouttelettes dans le volume turbulent homogène isotrope. La précision obtenue sur les diamètres (2% pour des gouttes de 60 μm) vient complètement valider cette métrologie pour l’étude de l’évaporation. Les premiers résultats obtenus avec des gouttelettes évaporantes de fréon R114 font apparaître la visualisation, à notre connaissance inédite, des sillages évaporants. Une première reconstruction de trajectoire avec l’évolution du diamètre de la goutte au cours du temps est enfin présentée. / This experimental thesis is based on the developpement of experimental tools in order to better understand the coupling between evaporation process and turbulent flow. Our studies focuses on evaporating droplets with strong interaction with turbulent flow, i.e. droplets between fluid particles behaviour and inertial behaviour. This pecular situation is hardly studied regarding to scientific litterature. We first present experimental set up generating homogeneous isotropic turbulence with high Reynolds number and strong fluctuations. Then we present injection process of initially monodisperse droplets in the turbulent flow. Lagrangian instrumentation consists of the use of digital in-line holography (in collaboration with Laboratoire Hubert Curien à St Etienne). This metrology is definitely validated regarding to the accuracy on the droplet diameter measurements. Tracking algorithm is then proposed in order to reconstruct Lagrangian droplet trajectories. First results obtained with evaporating droplets are finally presented like evaporating trails, and time evolution of the diameter of a freon droplet.
135

Localisation absolue centimétrique par photogrammétrie aéroportée et GPS embarqués sur drone / Centimetric absolute localization using Unmanned Aerial Vehicles with airborne photogrammetry and on-board GPS

Daakir, Mehdi 11 December 2017 (has links)
Au cours de la dernière décennie, les drones ont été largement utilisés dans les domaines des applications civiles. La photogrammétrie aéroportée a trouvé place dans ces applications comme une solution efficace de modélisation 3D mais aussi comme un outil de mesure. Vinci-Construction-Terrassement est une entreprise privée spécialisée dans le secteur des Travaux Publics qui intègre les drones et la photogrammétrie comme une solution de cartographie et de métrologie de ses chantiers. Cet outil est très efficace, par exemple, pour le calcul des volumes de stocks ou pour le suivi temporel de zones spécifiques avec un risque de glissement de terrain. Le but de ce travail est d’arriver à un géo-référencement direct des images acquises par la caméra lors du vol en s’appuyant uniquement sur un récepteur GPS embarqué. Le système utilisé doit être de faible coût et par conséquent le traitement des données est adapté à cette contrainte / Over the last decade, drones have been largely used for civil applications. Airborne photogrammetry has found place in these applications as a modeling and a measuring tool. Vinci-Construction-Terrassement is a private company of public building and works sector that integrates drones and photogrammetry as a mapping solution and metrology investigation on its sites. This tool is very efficient for the calculation of stock volumes for instance, or for time tracking of specific areas with risk of landslides. The aim of the present work is to do direct georeferencing of images acquired by the camera leaning on an embedded GPS receiver. The UAS used needs to be low cost and therefore data processing is adapted to this constraint
136

Métrologie de la fréquence de transition 1S-3S dans l'hydrogène : contribution au débat sur le rayon de charge du proton / Frequency metrology of the 1S-3S transition of hydrogen : contribution to the proton charge radius puzzle

Fleurbaey, Hélène 26 October 2017 (has links)
La mesure précise de la fréquence de la transition 1S-3S de l'atome d'hydrogène est d'un grand intérêt pour l'énigme du rayon de charge du proton, qui a pour origine les résultats récents de la spectroscopie de l'hydrogène muonique. Nous excitons la transition à deux photons 1S-3S, dans un jet d'atomes d'hydrogène, à l'aide d'un laser continu à 205 nm obtenu par somme de fréquences dans un cristal non-linéaire. La fréquence de la transition est mesurée par rapport à l'horloge à césium du LNE-SYRTE à l'aide d'un peigne de fréquence. L'enregistrement du signal pour différentes valeurs d'un champ magnétique appliqué permet d'estimer la distribution de vitesse des atomes du jet et d'en déduire l'effet Doppler du deuxième ordre. Les autres effets systématiques qui déplacent la transition ont été pris en compte : interférence quantique, déplacement lumineux, collisions. Une étude systématique en fonction de la pression a permis de montrer que la distribution de vitesse ne dépend pas de la pression et de déterminer le déplacement collisionnel. Finalement, une valeur de la fréquence de transition 1S-3S est obtenue avec une incertitude d'environ 5 kHz, ou 1,7 10^-12 en valeur relative. Elle est en très bon accord avec la valeur recommandée par le CODATA. Cette nouvelle mesure contribue à la recherche autour de l'énigme du rayon du proton. / The precise measurement of the 1S-3S transition frequency of hydrogen could have a great impact on the proton charge radius puzzle, which results from the recent spectroscopy of muonic hydrogen. In our experiment, the two-photon 1S-3S transition is excited in a hydrogen atomic beam, with a continuous-wave 205-nm laser which is obtained by sum frequency generation in a non-linear crystal. The transition frequency is measured with respect to the LNE-SYRTE Cs clock by means of a frequency comb. Recording the signal for several values of an applied magnetic field allows to estimate the velocity distribution of the atoms in the beam and deduce the second-order Doppler shift. Other frequency-shifting systematic effects have been taken into account: cross-damping, light shift, collisions. A complete study has shown that the velocity distribution does not depend significantly on the pressure, and allowed to determine the collisional shift. Eventually, a value of the 1S-3S transition frequency is obtained with an uncertainty of about 5 kHz, or a relative uncertainty of 1.7 10^-12. It is in very good agreement with the CODATA recommended value. This new measurement contributes to the ongoing search to solve the proton radius puzzle.
137

Oscillations de Bloch d'atomes ultra-froids : application aux mesures de haute précision / Bloch oscillations of ultra-cold atoms : application to high-precision measurements

Andia, Manuel 25 September 2015 (has links)
Ce travail de thèse se développe autour de trois expériences. La première concerne la mesure du rapport h/m entre la constante de Planck et la masse d'un atome de rubidium. Dans le cadre de l'étude détaillée des effets systématiques, tels que la phase de Gouy ou l'effet Zeeman quadratique, nous avons développé une nouvelle source laser compacte et puissante (12W@780nm) permettant de réduire l'effet de la phase de Gouy d'un facteur 4. La deuxième expérience a porté sur la démonstration d'un nouveau schéma de gravimètre compact, s'appuyant sur les oscillations de Bloch pour faire léviter les atomes. Une mesure de l'accélération locale de la pesanteur a été réalisée avec une sensibilité préliminaire très prometteuse de 4.7E-7 g en 1s. La troisième expérience a permis d'obtenir un interféromètre atomique symétrique grâce à la technique de double diffraction Raman. Nous avons réalisé la chaîne de fréquences et le montage optique pour l'intégration de séparatrices à grand transfert d'impulsion (LMTBS) à base d'oscillations de Bloch. / This work developed around three experiments. The first one concerned the measurement of the ratio h/m between Planck's constant and rubidium atomic mass. We have carried out a thorough study of systematic effects, such as the Gouy phase or the quadratic Zeeman effect. The development of a new compact and high-power laser source (12W@780nm) allowed to decrease the effect of Gouy phase by a factor of 4. The second experiment revolved around the realization of a compact and precise gravimeter, using Bloch oscillations to maintain atoms against gravity. This allowed for a measurement of local gravity acceleration with a promising preliminary sensitivity of 4.7E-7 g in 1s. Finally, the third experiment consisted in the realization of the double diffraction technique, with the aim of implementing Bloch-oscillation-based large momentum transfer beamsplitters.
138

Condensat de Bose-Einstein par refroidissement évaporatif dans un piège dipolaire pour la métrologie par interférométrie atomique / Bose-Einstein condensate by evaporative cooling in a dipole trap applied to metrology by atom interferometry

Courvoisier, Clément 07 October 2016 (has links)
Le travail de recherche réalisé dans le cadre de mon projet de doctorat a consisté à concevoir, construire et caractériser un nouveau dispositif expérimental fondé sur une source atomique refroidie par évaporation dans un piège dipolaire optique. Il vise à améliorer l’incertitude sur la mesure du rapport h/m entre la constante de Planck et la masse d’un atome de rubidium, en réduisant l’effet de la phase de Gouy et de courbure du front d’onde.Dans un premier temps, nous avons étudié différentes configurations optiques pour optimiser le taux de chargement du piège dipolaire : le faisceau de 50 W à 1070 nm est mis en forme pour constituer un double faisceau réservoir de 93 µm de waist, ainsi qu’un faisceau fin croisé de waist 20 µm. Après avoir optimisé et caractérisé le processus d’évaporation, nous avons obtenu un condensat de Bose-Einstein.Par ailleurs, nous avons mis en place, pour l’interférométrie Raman, un nouveau système laser utilisant des sources primaires à 1560 nm doublées en fréquence. Nous avons conçu un double asservissement : il permet d’une part d’asservir en phase les deux sources laser et, d’autre part, de corriger le bruit de phase accumulé dans les amplificateurs à fibres.Le nouveau dispositif expérimental est aujourd’hui prêt à réaliser l’interférométrie atomique sur le condensat de Bose-Einstein. / This research work fulfilled as part of my PhD project involved to design, build and characterise a new experimental setup based on an atom source by evaporative cooling in an optical dipole trap. It goes after the improvement of the uncertainty on the measurement of the ratio h/m between Planck’s constant and the rubidium atom mass, reducing the Gouy phase and wavefront curvature.In a first step we have studied several optical configurations to optimise the dipole trap loading: the 50 W beam at 1070 nm is shaped in a double 93 µm waist reservoir and one crossed 20 µm waist dimple. After having optimised and caracterised the evaporative process, we obtained one Bose-Einstein condensate.Furthermore, for Raman interferometry, we set up a new laser system at 1560 nm based on frequency doubling. We developed a double cervo loop: on the one hand, it allows to phase lock the two laser sources, and on the other hand to correct phase noise accumulated in fibered amplifiers.Today, our new experimental setup is ready to perform atom interferometry on a Bose-Einstein condensate.
139

Chats de Schrödinger d'un atome de Rydberg pour la métrologie quantique / Schrödinger cat states of a Rydberg atom for quantum metrology

Facon, Adrien 02 December 2015 (has links)
Il n'y a pas de limite fondamentale à une mesure classique : la position d'une aiguille sur un cadran peut être déterminée avec une incertitude arbitrairement faible. Au contraire, dans le monde quantique, la précision de toute mesure est limitée par le bruit quantique. Lorsque l'aiguille de mesure devient un système mésoscopique, tel un moment cinétique J qui évoluerait sur le cadran sphérique d'une sphère de Bloch, les fluctuations quantiques affectant les états cohérents conduisent alors à une incertitude de mesure en 1/√J appelée limite quantique standard. La métrologie quantique consiste à préparer l'aiguille dans un état quantique qui permet de dépasser cette limite et d'atteindre la précision ultime fondamentale, dite limite de Heisenberg, qui évolue en 1/J. Nous proposons et réalisons une approche innovante fondée sur la mesure de la phase relative d'une superposition d'états mésoscopiques du type Chat de Schrödinger. En utilisant un champ radiofréquence polarisé, nous avons en effet pu préparer un atome de Rydberg dans une superposition quantique du moment cinétique décrivant l'électron, dont la sensibilité au champ électrique approche la limite de Heisenberg. Cette méthode a permis la réalisation d'un électromètre à un seul atome mesurant de faibles champs de l'ordre du mV/cm en quelques dizaines de nanosecondes. La grande sensibilité de ces méthodes de mesure de champ résolue en temps et en espace ouvre la voie à de nombreuses applications. / There is no fundamental limit to the precision of a classical measurement. The position of a meter’s needle can be determined with an arbitrarily small uncertainty. In the quantum realm, fundamental fluctuations due to the Heisenberg principle limit the precision of any measurement. When the needle is replaced by a mesoscopic system, for instance a spin J evolving on a spherical dial, the Bloch sphere, the semi-classical spin coherent state quantum fluctuations lead to a measurement uncertainty scaling as 1/√J, the standard quantum limit (SQL). This is far from the ultimate Heisenberg limit (HL), which scales as 1/J. We present here an innovative approach, using interferometric measurements on mesoscopic Schrödinger-cat-like superpositions of Rydberg states to realize a single-atom electrometer measuring weak fields of the order of 1 mV/cm in a few tens of nanoseconds. The sensitivity of this method is beyond the SQL and we check that its uncertainty scales as the HL. The extreme sensitivity of this non-invasive space- and time-resolved field measurement could have many practical applications.
140

Quantification des mouvements de la mimique faciale par motion capture sur une population de volontaires sains / Quantification of facial movements by motion capture on healthy volunteers

Sarhan, François-Régis 14 June 2017 (has links)
La prise en charge des déficits moteurs de la mimique faciale est complexe et nécessite un suivi sur le long terme. Il existe de nombreuses techniques d’évaluation de la mimique faciale déficitaire avec des degrés variables de sensibilité. Cependant, la plupart de ces techniques sont manuelles et qualitatives (testing musculaire et scores cliniques). Elles conduisent donc à des mesures subjectives et peu reproductibles dans le temps. Ces techniques d’évaluation reposent en outre sur l’appréciation de l’évaluateur qui est une source importante de biais. Ainsi, l’apport d’un outil de mesure objectif pour quantifier un déficit et optimiser le suivi et la prise en charge médicale, chirurgicale et rééducative des patients apparait comme nécessaire. L’objectif de ce travail de thèse était donc de développer un outil quantitatif permettant d’évaluer les troubles de la mimique faciale. Dans cette perspective, nous avons mis en place un protocole d’analyse du mouvement par motion capture et avons réalisé des mesures sur une population de référence. Une étude descriptive utilisant un système de capture de mouvement en 3 dimensions a été réalisée sur des volontaires sains (n = 30) âgés de 20 à 30 ans. Le système de capture du mouvement était constitué de 17 caméras optoélectroniques T160 et de 2 caméras vidéo Bonita (Vicon™). Les mouvements étudiés étaient : la fermeture « simple » (non forcée) des paupières, la fermeture forcée des paupières, la protrusion labiale sur le son « o » [o], la protrusion labiale sur le son « pou » [pμ], et un sourire volontaire découvrant les dents. Lors de ces mouvements, nous avons enregistré et analysé le déplacement de 111 marqueurs réfléchissants de 1.5mm placés sur la face des sujets. Pour les cinq mouvements réalisés, nous avons obtenu des données quantitatives. Celles-ci nous ont permis d’identifier les zones d’action pour chacun des mouvements, de mesurer l’amplitude des déplacements et d’obtenir des données comparables dans le temps. Par ailleurs, le protocole mis en place a été évalué et sa réalisation est compatible avec une application clinique. L’analyse de la cinématique de la face est donc une technique appropriée à la clinique qui pourrait faciliter le diagnostic, le suivi et la rééducation des patients. Ce travail a permis de définir des mesures de référence qui constitueront la base d’un outil diagnostic, qu’il convient désormais de mettre en œuvre sur des patients. / The care of facial paralysis is often complex and therefore requires monitoring over the long term. There are many clinical severity scores with varying levels of sensitivity to assess the deficit of facial movement, but most of them are qualitative. The number of assessment methods is an obstacle to monitor patients and treatment evaluation. We need an objective measurement tool to provide reliable measures of resting asymmetry, symmetry of voluntary movement and synkinesis. The aim of this study is to determine if the 3D motion capture of the face is compatible with these clinical criteria. A descriptive study using a 3-dimensional (3D) motion capture system were performed on healthy volunteers (n=30) age from 20 to 30 years. The motion capture system consists of 17 optoelectronic cameras at a frequency of 100Hz. We captured the movements of the face on healthy volunteers. We obtained absolute values: 3D coordinates and relative displacements. These data were free of manual measurements, and the use of 3D motion capture does not impede the facial movement. The average time of capture was less than 10 minutes. The measurements are painless for subjects. Data are collected in a computer and can be easily exported. These results show the feasibility of 3D motion capture of facial movement. The protocol used here could be standardized to be routinely relevant. lt was used in an experimental study to follow up recovery of a facial transplantation. This technique could help to overcome the uncertainty caused by subjective assessment and optimize therapeutic choices.

Page generated in 0.0459 seconds