• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 16
  • Tagged with
  • 51
  • 33
  • 16
  • 16
  • 12
  • 11
  • 11
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Spatial variation of radio frequency magnetic field exposure from clinical pulse sequences in 1.5T MRI / Spatial variation av radiofrekvent magnetfältsexponering från kliniska pulssekvenser i 1,5T MRT

Forsberg, Andreas January 2014 (has links)
Cell biological exposure studies in magnetic resonance imaging (MRI) environment, where a complex mixture of strong magnetic fields are present, have attracted considerable interest in recent years. The outcome of such studies might depend strongly on the conditions, for example exposure parameters and spatial variations of exposure. The aim of this thesis has been to give a detailed description of how the radio frequency (RF) magnetic field varies with position and sequence choice within an MRI bore from a patient perspective and to highlight the need of better consistency in future research. Method: A straightforward theoretical description on the contribution to the RF magnetic field from a birdcage coil is given. A one dimensional coaxial loop antenna has been used as a probe to measure spatial variations of the RF magnetic field in a 1.5T MRI scanner. An exposure matrix containing RF magnetic field strength (H1-field) amplitudes in three dimensions was constructed and used to study several clinical protocols and sequences. A qualified correspondence measurement was also made on a 3T MRI scanner. Results: Around isocenter, for a common field-of-view (FOV), changes in exposure conditions were small; however, rapid changes of exposure conditions occurred upon approaching the end rings. The dominating H1-field component switched from lying in the xy-plane to pointing the z-direction and was roughly 3 times larger than in isocenter. Practical difficulties indicate even larger differences at positions not measurable with the equipment at hand. The strongest H1-field component was 32.6 A/m at position (x,y,z)=(-24,8,24) cm from the isocenter. Conclusions: Machine parameters such as repetition time, echo time and flip angle have little to do with actual exposure. Specic absorption rate (SAR) values correlated well with the square of measured root-mean-square (RMS) values of the magnetic field (B1,RMS) but not with peak values of the magnetic field (B1,peak), indicating that peak values are not unlikely to be part of compromising factors in previous contradictory exposure research on genotoxicity. Furthermore exposure conditions depend strongly on position and unfavorable situations may occur in the periphery of the birdcage coil. Potentially elevated risks for conducting surfaces, for example arms or external fixations, in the proximity of the end rings, are proposed. Aside from spatial variation consideration on which type of geometry exposed cell-biological samples are placed in should be held since eddy currents, hot-spots and proper SAR depend on geometry. Conditions may vary considerably between in-vitro, ex-vivo and in-vivo studies since geometries of test tubes, petri dishes and humans differ.
12

Petrophysic of the Host-rock to the Ore in the Lovisa Mine, Bergslagen / Petrofysik hos det malmnära sidoberget i Lovisagruvan, Bergslagen

Gilljam Päärt, Oscar January 2019 (has links)
The Bergslagen region has three base-metal mines operating today, and one of them is the Lovisa mine, which host a Zn-Pb-Ag deposit. The Lovisa mine is located in the Guldsmedshyttan area north of Lindesberg. The mine is part of in the X-Mine H2020 project that includes four different mines with the aim of an improved environmental resource management. The project aims at reducing the environmental impact from transport, ore processing and chemical handling as well as result in lowering the costs per produced amount of metal. The purpose for this thesis is to determine the petrophysical characteristics of the host rocks to the thin tabular mineralised units in the Lovisa mine with petrophysics. Petrophysics is used to obtain information about the physical properties of rocks, which is then is integrated with geophysics and the geology, to obtain an improved understanding about the different geophysical anomalies. The petrophysic methods used here, reviled three different physical properties of the rocks: density, magnetic volume susceptibility and natural remanent magnetization. These properties were measured on five different drill cores and correlated with the literature data and lithologies of the core. The lithologies close to the ore correspond to literature data for volcanic siltstone, volcanic sandstone, massive rhyolite, skarn (calc-silicates) and dolomite. Dolomite is not present in the cores and corresponds to breccia, volcanic sandstone and skarn. My conclusion for this method, is that in order to do a lithological interpretation based on the measured petrophysical properties, is that a good knowledge of the lithologies as well as a good understanding of the geological processes that have affected the rocks in the investigated area are required. / I Bergslagen finns det idag tre aktiva gruvor som bryter sulfidmalm, och en av dem är Lovisagruva som är en malmkropp Zn-Pb-(Ag)-malm. Lovisagruvan ligger i Guldsmedshytteområdet, norr om Lindesberg. Gruvan är en del av X-Mine-projektet som bl.a. undersöker små, komplexa malmkroppar i syfte att reducera miljöpåverkan och effektivisera produktionen. Syftet med detta kandidatarbete är att bestämma petrofysiska egenskaper hos lithologin i det malmnära sidoberget vid Lovisagruva. Petrofysik används för att ta reda på bergets fysikaliska egenskaper, och dessa egenskaper används sedan inom geofysik, för att få en förståelse för de olika avvikelser som visas i andra geofysiska mätningar. De petrofysiska mätningarna som utfördes, gav tre fysikaliska egenskaper hos varje prov, densitet, magnetisk susceptibilitet och den naturliga magnetiska remanensen. Resultaten från varje prov korrelerades sedan med litteraturdata och jämfördes med borrkärneloggar från Lovisa. De petrofysiska mätningarna utfördes på prover från fem olika borrhål. Resultatet visar att det malmnära sidoberget korrelerar med litteraturdata på vulkanisk siltsten, vulkanisk sandsten, kalksilikat, ryolit, skarn och dolomit. Dolomit finns inte i kärnorna utan representeras av bl.a. breccia, vulkanisk sandsten och skarn. Min slutsats är att det går att bestämma lithologin med dessa fysikaliska egenskaper, men man måste ha en god kännedom om vilka bergarter som förväntas att förekomma i området samt vilka geologiska processer som påverkat dem. / H2020 X-mine
13

Rock Magnetic Studies of Magnetite and Quartzite: Results at Ambient Conditions and From Diamond Anvil Pressure Experiments (~2 GPa) / Magnetiska studier av magnetit och kvartsit:Resultat vid rumsförhållanden och från diamantstädcell (DAC) högtrycksexperiment

Daniil, Dimitra January 2021 (has links)
Numerous techniques are used to study the magnetic history and properties of rocks, which provides important data on the Earth’s interior. In this study we conducted a series of experiments on two different sample sets, comprising pure magnetite (Set1) and a mixture of magnetite-hemoilmenite-bearing quartzite (Set2), in order to gather information about their magnetic susceptibility and remanent magnetization. A miniature diamond anvil cell (mDAC) constructed from hardened non-magnetic alloy (40HNU) was used for high pressure experiments. With the help of high sensitivity susceptibility bridge (MFK1-FA Kappabridge, AGICO), we measured the susceptibility of three samples and of the mDAC. Consequently, we loaded one of the samples in the mDAC and acquired susceptibility measurements during the compression and decompression of the system. For remanence measurements we used a 2G Enterprises SQUID magnetometer. We measured the natural remanent magnetization (NRM) and performed alternating field (AF) demagnetization on ten samples and on the mDAC. Additionally, isothermal and anhysteretic remanent magnetization (IRM and ARM) acquisition were performed on nine and one samples, respectively and demagnetization on three and one samples, respectively. Results showed that Set1 samples consist of both SD and MD magnetite grains. Regarding Set2 samples, the main magnetic carriers are SD and MD magnetite or titanium bearing magnetite grains, while there are indications that hematite and ferrimagnetic titanohematite might be present as well. The presence of eddy currents, due to the conducting materials of the mDAC, resulted in masking the signal of the sample making it difficult to draw any safe conclusions regarding how the susceptibility of the sample changes with pressure. All in all, there was a satisfactory response of the instruments working with very small amounts of material and an adequate signal stability of both the samples and the mDAC. Our study provided us with an insight into high pressure experiments and showed possible directions for future studies. / Många metoder används för att studera magnetiska egenskaper i berg, vilket ger viktig information om Jordens inre. I denna studie genomförde vi en rad experiment på två olika uppsättningar prov, innefattande ren magnetit (Set1) och en blandning av magnetit-hemoilmenit-bärande kvartsit (Set2), för att samla information om deras magnetisk susceptibilitet och magnetiska remanens. En miniatyr diamantstädcell (mDAC) konstruerad av en härdad icke-magnetisk legering (40HNU) användes för högtrycksexperiment. Susceptibilitetet av tre prover och av mDAC mättes en MFK1-FA Kappabridge, AGICO. Följaktligen monterade vi ett av proverna i mDAC och vi genomförde susceptibilitetsmätningar under kompression och dekompression. Vi använde en 2G Enterprises SQUID magnetometer för remanensmätningar. Den naturlig remanentmagnetiseringen (NRM) mättes och vi utförde alternerande fält (AF) demagnetisering på tio prover och på mDAC. Dessutom genomfördes isotermisk och anhysteretisk remanentmagnetisering (IRM och ARM) på nio respektive ett prover, och demagnetisering på tre respektive ett prover. Resultaten visade att Set1-prover består av både enkeldomän (SD) och multidomän (MD) magnetit. SD och MD magnetit- och titanomagnetitkorn är de viktigaste magnetiska mineral av Set2-prover, medan finns det indikationer på att hematit och ferrimagnetisk titanohematit också bidrar till signal. Virvelströmmar, som skapats av mDACs ledande material, maskerade provets magnetiska susceptibilitet och det var svårt att kommentera på hur provets susceptibilitet förändras med tryck. Sammantaget var instrumentens prestanda tillfredsställande, även vid små mängder material. Prov och mDACs signalstabilitet var också adekvat. Vår studie gav oss en inblick i högtrycksexperiment och magnetiska egenskaper och den visade möjliga riktningar för framtida studier.
14

Polymerutvärdering med hänsyn till genomsläpplighet av radiofrekvensvågor / Polymer evaluation with consideration to radio wave transmittance

Odicho, Marwa January 2019 (has links)
No description available.
15

Tertiary Storage in Digital Video Archives / Bruk av tertiære lagringsmedia i digitale videoarkiv

Sandstå, Olav January 2004 (has links)
<p>In order to efficiently manage the large amounts of video data stored in a digital video archive, computerized management systems must be developed for storing and making the video available to users. In this thesis, we study tertiary storage technologies and storage architectures for storing and retrieving digital video in video archives.</p><p>We evaluate serpentine tape as a storage medium for digital video. In order to increase the performance of storage systems using serpentine tape, we present and evaluate a detailed access-time model for serpentine tape and a novel scheduling algorithm for optimizing concurrent accesses to the tape. The scheduling algorithm is used for evaluating serpentine tape for storing images and video sequences. The main conclusion is that by using the access-time model and the proposed scheduling algorithm, it is possible to achieve significant improvements in initial latency, average access time, and the number of requests that can be served by a single tape drive.</p><p>Tertiary storage technologies including magnetic tape and DVD are evaluated for use in digital video archives. The evaluation is performed using a simulator of the storage system of a video archive. The simulation model is based on the architecture of the Elvira~II video archive server. Different configurations for the storage system are evaluated with regards to performance and cost. In the evaluation different allocation strategies, access distributions, and user loads are studied. The effect of using a cache based on magnetic disks is investigated.</p><p>The main conclusion is that the choice of architecture and storage technology for a video archive depends on the user generated load, the size of the requested video sequences, and the access distribution for the stored videos. It also depends on whether throughput, response time, storage cost, or cost per retrieved video is the main evaluation criterion. Furthermore, we show that a video archive based on DVD as the main storage technology outperforms a video archive using magnetic tape, and that including a relatively small disk cache in most cases improves the performance and reduces the total cost of the archive. </p><p>The ideas and results presented in this thesis are also useful outside the video archive context. The strategies and results are beneficial for applications that require hierarchical storage management systems for managing large data volumes.</p>
16

Automatiserad provrörskarusell : Elektronikkonstruktion och utvärdering / Automated sample tube mover

Rosenfeld, Carl January 2010 (has links)
<p>Den här rapporten beskriver arbetet med en automatiserad provrörsförflyttare. Det är ett examensarbete som har gjorts på företaget Q-linea AB. En karuselliknande konstruktion med en stegmotor användes för att flytta prover mellan ett antal positioner. En mikrokontroller som hanterar styrning och sensordata har programmerats i C. LabVIEW och en USB-kamera har använts som hjälp till att göra utvärderingar och tester av systemet. Målet var att konstruera en prototyp som uppfyllde de precisionskrav och tidskrav som ställdes, vilket också uppnåddes. Rapporten beskriver arbetsgången och avslutas med rekommendationer för fortsatt arbete. Rapporten innehåller en teoridel som kan användas till hjälp för att konstruera liknande system, d.v.s. roterande positioneringstillämpningar.</p> / <p>This thesis describes the work of an automated sample tube mover. This is a degree project and has been done at the company Q-linea AB. A carousel similar construction with a stepper motor has been designed for the task to move samples between a numbers of positions. A microcontroller has been programmed to control the movements and handle sensor data. LabVIEW have been used together with an USB-camera in order to do evaluations and tests of the system. The goal was to design a prototype that fulfills the demanded requirements of precision and timing, which also was achieved. The thesis describes the work process and concludes with recommendations for further work.</p>
17

Tertiary Storage in Digital Video Archives / Bruk av tertiære lagringsmedia i digitale videoarkiv

Sandstå, Olav January 2004 (has links)
In order to efficiently manage the large amounts of video data stored in a digital video archive, computerized management systems must be developed for storing and making the video available to users. In this thesis, we study tertiary storage technologies and storage architectures for storing and retrieving digital video in video archives. We evaluate serpentine tape as a storage medium for digital video. In order to increase the performance of storage systems using serpentine tape, we present and evaluate a detailed access-time model for serpentine tape and a novel scheduling algorithm for optimizing concurrent accesses to the tape. The scheduling algorithm is used for evaluating serpentine tape for storing images and video sequences. The main conclusion is that by using the access-time model and the proposed scheduling algorithm, it is possible to achieve significant improvements in initial latency, average access time, and the number of requests that can be served by a single tape drive. Tertiary storage technologies including magnetic tape and DVD are evaluated for use in digital video archives. The evaluation is performed using a simulator of the storage system of a video archive. The simulation model is based on the architecture of the Elvira~II video archive server. Different configurations for the storage system are evaluated with regards to performance and cost. In the evaluation different allocation strategies, access distributions, and user loads are studied. The effect of using a cache based on magnetic disks is investigated. The main conclusion is that the choice of architecture and storage technology for a video archive depends on the user generated load, the size of the requested video sequences, and the access distribution for the stored videos. It also depends on whether throughput, response time, storage cost, or cost per retrieved video is the main evaluation criterion. Furthermore, we show that a video archive based on DVD as the main storage technology outperforms a video archive using magnetic tape, and that including a relatively small disk cache in most cases improves the performance and reduces the total cost of the archive. The ideas and results presented in this thesis are also useful outside the video archive context. The strategies and results are beneficial for applications that require hierarchical storage management systems for managing large data volumes.
18

Automatiserad provrörskarusell : Elektronikkonstruktion och utvärdering / Automated sample tube mover

Rosenfeld, Carl January 2010 (has links)
Den här rapporten beskriver arbetet med en automatiserad provrörsförflyttare. Det är ett examensarbete som har gjorts på företaget Q-linea AB. En karuselliknande konstruktion med en stegmotor användes för att flytta prover mellan ett antal positioner. En mikrokontroller som hanterar styrning och sensordata har programmerats i C. LabVIEW och en USB-kamera har använts som hjälp till att göra utvärderingar och tester av systemet. Målet var att konstruera en prototyp som uppfyllde de precisionskrav och tidskrav som ställdes, vilket också uppnåddes. Rapporten beskriver arbetsgången och avslutas med rekommendationer för fortsatt arbete. Rapporten innehåller en teoridel som kan användas till hjälp för att konstruera liknande system, d.v.s. roterande positioneringstillämpningar. / This thesis describes the work of an automated sample tube mover. This is a degree project and has been done at the company Q-linea AB. A carousel similar construction with a stepper motor has been designed for the task to move samples between a numbers of positions. A microcontroller has been programmed to control the movements and handle sensor data. LabVIEW have been used together with an USB-camera in order to do evaluations and tests of the system. The goal was to design a prototype that fulfills the demanded requirements of precision and timing, which also was achieved. The thesis describes the work process and concludes with recommendations for further work.
19

Karaktärisering, utvärdering och avsättning av Stena Metalls magnetiska fines

Assarsson, Karin January 2014 (has links)
With a growing population on earth the amount of end-of-life vehicles (ELVs) and other scrap steel increases. The European Directive 2000/53/CE” requires a minimum of 95 % reuse and recovery and 85 % re-use and recycling no later than 1 January 2015, for end-of life vehicles. This imposes a need for more efficient recycling and recovery. Despite this shredder residue (SR) is commonly land filled. This report investigated the magnetic fines residue generated at Stena Metall shredder facility in Halmstad, Sweden. Magnetic fines is a complex material containing e.g. ferrous metals, non-ferrous metals, glass, plastic, rubber, polyurethane, sand, dirt, brominated flame retardants and PCB. Characterisation of the material and discussion around area of application resulted in suggestions for possible recycling alternatives. Characterisation included e.g. particle size, total organic content, x-ray fluorescence, x-ray powder diffraction and elemental analysis with a focus on the metals. The results indicated a higher organic content in larger particles and an increasing content of e.g. lead, cadmium and mercury in smaller particles. X-ray fluorescence can be used to measure lead in magnetic fines. The conclusion was that the combustible organic content needs to be separated before further metal recycling can be applied. If magnetic fines should be used in construction pollutants probably either needs to be removed or encapsulated to prevent exposure to humans and environment.
20

Variations in the target definition on CT and MR based treatment plans for radiotherapy / Skillnader mellan definition av targetvolym på CT och MR baserade behandlingsplaner för strålterapi

Svensson, Sara January 2014 (has links)
The introduction of Magnetic Resonance (MR) Imaging in treatment planning for radiotherapy of prostate cancer give rise to new challenges in defining the treatment volume, or the target. Imaging with MR have several advantages, especially better soft-tissue contrast, compared with the standard image modality, Computed Tomography (CT). The purpose of this project was to determine how the target definition varies with the choice of image modality and the systematic differences between them. The purpose was also to determine how the inter- and intra physician variability influences the delineation, depending on which image modality that is used. In the project, five physicians delineated the prostate gland on CT and MR images for nine patients. The physicians had no information of which image series that was connected, and were thus delineating independent. After the delineation, the CT and MR image series was set in the same geometrical coordinate system in the treatment planning system Oncentra. The target delineations were analysed by comparing the radial distances from the centre of mass in different directions, such as anterior, posterior, etc. The radial distances were later used to evaluate the variability of the delineations and to determine the inter and intra physician variability in different directions of the targets. ANOVA was also preformed to determine if there is a significant difference between the parameters, as the image modality and the image modalities influence on the physicians delineations. A model was made to investigate how the MR delineations differ from a CT defined volume that 95% of the delineations cover, called the ideal CT delineation. From this, the median deviation in different directions  was analysed and it was found that the median value of the MR delineations in different directions was between -0.10-2.27 mm larger than the ideal CT delineation. The fluctuations between the delineations was, however, large. The target volume was larger for CT defined volumes in 87% of the cases, compared with MR targets. The inter physician variability was found to be between 0.54-2.17 mm for the CT based delineations and 0.68-2.08 mm for the MR based target delineations. The intra physician variability was larger than the inter physician variability, between 0.74-2.51 mm for CT based delineations and 0.85-1.45 mm for MR based delineations. The median variability of the delineations were not uniform around the target volume but were larger for example in the superior and inferior directions and had its minimum in the posterior direction. The ANOVA tests showed a significant difference between MR and CT based target delineations, it also shows a relation between the delineating physician and the image modality, meaning that the physicians are delineating different on CT and MR images. Target volumes defined on MR images are in general smaller than the CT defined targets. The soft tissue contrast in MR images makes the delineating process easier, however, the analysis of the variability in this project indicates that the variations of MR based target delineations are larger than the CT based. The large variation of the delineations implies that clinical tests should be made to ensure a proper dose coverage before MR could be used as the only image modality in radiotherapy treatment planning of prostate cancer.

Page generated in 0.0325 seconds