51 |
Adaptação marginal de restaurações em resina composta expostas a diferentes agentes clareadores / Marginal adaptation of resin composite restorations exposed to bleaching agentsAbe, Andréa Tami 09 April 2018 (has links)
Este estudo teve como objetivo avaliar a adaptação marginal de restaurações em resina composta confeccionadas utilizando-se como agentes adesivos sistemas de diferentes estratégias de interação, expostas a agentes clareadores e submetidas a ciclagem mecânica, por meio de avaliação em tomografia por coerência óptica (OCT). Para este estudo foram utilizados 90 molares humanos hígidos recém-extraídos. Uma cavidade classe V foi confeccionada na face vestibular de cada dente com a margem oclusal localizada em esmalte e a margem cervical em cemento/ dentina. Os espécimes foram divididos em 3 grupos experimentais, de acordo com o sistema adesivo utilizado (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). As cavidades foram então preenchidas com a resina composta nanoparticulada Filtek Z350XT, e em seguida o acabamento e o polimento foram realizados. Os espécimes foram submetidos a duas ciclagens mecânicas, sendo a primeira antes e a segunda após o clareamento. Ao final da primeira ciclagem, os espécimes foram subdivididos em 3 grupos (n=10) de acordo com o tratamento realizado (controle - água destilada, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). As imagens em OCT das restaurações foram obtidas em 4 momentos diferentes (antes da primeira ciclagem, depois da primeira ciclagem, após o tratamento e depois da segunda ciclagem). A interface dente-restauração foi analisada de duas formas, por meio de classificação das fendas por escore e mensuração da profundidade da fenda em micrômetros (?m), para esmalte e dentina separadamente. Os valores de escore foram analisados com o teste estatístico não-paramétrico de Kruskal-Wallis (p<0.05), e para os dados de profundidade de fenda em ?m, a ANOVA dois fatores (p<0.05) e teste de Tukey foram empregados. A correlação de Spearman foi empregada para correlacionar esses dois dados e foi observada uma correlação forte entre os dados de escore e de profundidade em ?m (r=0.85 p<0.0001). A comparação entre os grupos, tanto por escores quanto por profundidade em ?m, demonstraram que as fendas observadas após a primeira ciclagem foram estatisticamente maiores (p<=0.05) do que as fendas observadas inicialmente, exceto para a análise por escores, onde essa diferença foi detectada apenas para o adesivo SB2. O adesivo SBU apresentou as menores fendas marginais tanto em esmalte quanto em dentina. Em esmalte o adesivo CSE mostrou-se mais estável à degradação e em dentina não foi observada diferença estatisticamente significante entre os adesivos CSE e SB2. Entre os diferentes tratamentos, nenhuma diferença foi observada, independente do tempo de análise e do adesivo utilizado. Pode-se concluir que os clareadores utilizados não promoveram alteração da integridade marginal das restaurações em resina composta, sendo que as fendas marginais observadas estão mais relacionadas ao efeito do envelhecimento por ciclagem mecânica e são dependentes do sistema adesivo utilizado. Foi observada correlação direta entre os dois métodos de análise para mensuração da fenda marginal, contudo a análise da profundidade em ?m, utilizando teste paramétrico, mostrou-se mais sensível para a detecção de diferenças. / The aim of this study was to evaluate the marginal adaptation of resin composite restorations using different dental adhesive systems, exposed to dental bleaching agents and mechanical load cycling, by evaluation using optical coherence tomography (OCT). For this study 90 sound recently extracted human molars were used. One class V cavity was prepared in the buccal surface of each tooth with occlusal margin in enamel and cervical margin in dentin. The specimens were divided into 3 experimental groups, according to the adhesive system used (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). The cavities were restored with the nanocomposite Filtek Z350XT, and then the finishing and polishing were done. The specimens were submitted to two mechanical load cycling, the first one before bleaching and the second one after it. By the end of the first load cycling, the specimens were subdivided into 3 groups (n=10) according to the treatment accomplished (control - distilled water, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). The OCT images of the restorations were obtained in 4 distinct moments (before the first load cycling, after the first load cycling, after the treatment, and after the second load cycling). The tooth-restoration interface was analyzed by two ways: analyzing the gap by score and measurement of the gap depth in micrometer (?m), for enamel and dentin separately. The scores were analyzed with the non-parametric statistic test Kruskal-Wallis (p<0.05), and for the gap depth data, the two-way ANOVA (p<0.05) and Tukey test were used. The Spearman correlation were done to correlate these two data and a strong correlation between the score analysis an depth in ?m was observed (r=0.85 p<0.0001). The comparison between the groups, as by score as by depth in ?m, demonstrated that the gaps observed after the first load cycling were statistically deeper (p<=0.05) than the gaps observed initially, except for score analysis, when this difference was detected only for the adhesive SB2. The adhesive SBU showed less deep marginal gaps both in enamel and dentin. In enamel, the adhesive CSE was more stable to degradation and in the dentin no statistically difference was observed between the adhesives CSE and SB2. Between the different treatments, no difference was observed, regardless the evaluation time and the dental adhesive used. In conclusion, the bleaching agents used in this study did not affect the marginal integrity of resin composite restorations, thus the marginal gaps observed were more related to the aging by mechanical load cycling and were dependent of the dental adhesive system used. There was a direct correlation between both methods for marginal gap analysis, however the depth in ?m analysis, using parametric statistical test, showed more sensitive to detect differences.
|
52 |
Avaliação in vitro do efeito do clareamento dental prévio a cimentação de restaurações indiretas / In vitro evaluation of the effect of dental bleaching prior to cementation of indirect restorationsFogli, Silvia Stuber 05 June 2017 (has links)
O presente trabalho experimental, tem como objetivo avaliar \"in vitro\" possíveis falhas na cimentação de fragmentos cerâmicos sobre substrato de esmalte dentário previamente submetido ao clareamento dental e analisados pelo sistema de tomografia por coerência ótica. O ensaio experimental foi realizado in vitro, fazendo uso de trinta pré-molares superiores humanos. Cada elemento dental teve sua porção de esmalte vestibular aplainada por meio de disco de sílica na granulação 120, foram cimentados fragmentos cerâmicos retangulares de 1.5mm de espessura. Os dentes foram distribuídos aleatoriamente em 3 grupos de 10 dentes cada (n=10), Grupo 1: Fragmentos cimentados sem serem submetidos ao tratamento clareador; Grupo 2: Fragmentos cimentados 24 hrs. Após serem submetidos ao clareamento dental; Grupo 3: Fragmentos cimentados 7 dias após serem submetidos ao clareamento dental. Os espécimes foram transferidos para o sistema de tomografia por coerência óptica para seus respectivos monitoramentos após exposição ao agente clareador e cimentação da restauração indireta e ao final dos ensaios de envelhecimento artificial por termociclagem. A variável de resposta, falhas na interface esmalte e cimento resinoso, foi avaliada por escores (0,1 e 2) que representam em ordem crescente as falhas entre o substrato dental e a restauração indireta. Os valores obtidos foram analisados por meio de testes não paramétricos (Kruskal-Wallis e Wilcoxon). Os resultados constituíram de 60 escores de fendas referentes aos 3 grupos (G1;G2;G3) analisados imediatamente após a cimentação e após a termociclagem. A comparação entre os 3 grupos após termociclagem demonstrou haver diferença estatisticamente significante (p<0,0001) pela comparação dois a dois pelo teste complementar de Dunn e detectou-se que o G2 cimentado após 24 horas do clareamento apresentou mais fendas que G1 e G3. Com base nestes resultados e na metodologia utilizada pode-se concluir que, dentes submetidos ao tratamento clareador, o protocolo clinico de cimentação de restaurações cerâmicas indiretas, quando realizado 7 dias após o clareamento gerou menor quantidade de fendas na interface, propondo assim melhor qualidade na adaptação dente/restauração. / The present experimental study has the objective of evaluating in vitro possible failures in the cementation of ceramic fragments over dental enamel substrate previously submitted to dental bleaching and analyzed by optical coherence tomography system. The experimental trial was performed in vitro using thirty human maxillary premolars. Each dental element had have it\'s portion of vestibular enamel planed by a silic disk in granulation 120, ceramic fragments with a diameter of 1.5mm thickness were cemented. The teeth were randomly distributed in 3 groups of 10 teeth each (n = 10), Group 1: Bonded Veneer without being subjected to bleaching treatment Group 2: Bonded Veneer 24 hours after being submitted to dental bleaching Group 3: Bonded Veneer 7 days after being submitted to dental bleaching. The specimens were transferred to the optical coherence tomography system for their respective monitoring after being exposured to the whitening agent and cementation of the indirect restoration and at the end of the artificial aging tests by thermocycling. The variable of response, at faults in the interface enamel and resin cement, was evaluated by scores (0,1 and 2) that represent in increasing order the failures between dental substrate and indirect restoration. The values obtained were analyzed by non-parametric tests (Kruskal-Wallis and Wilcoxon). The results consisted of 60 gaps scores for the three groups (G1, G2, G3) analyzed immediately after bonding and after thermocycling. The comparison between the 3 groups after thermocycling, showed a statistically significant difference (p <0.0001) by the two-to-two comparison by Dunn\'s complementary test and it was detected that G2 after 24 hours of bleaching, showed more gaps than G1 and G3. Based on these results and the methodology used, it was concluded that, when teeth were submitted to the bleaching treatment, the clinical cementation protocol of indirect ceramic restorations, when performed 7 days after bleaching, generated fewer gaps at the interface, thus proposing a better quality in the relation Tooth / restoration.
|
53 |
Qualidade marginal de restaurações cervicais, feitas com materiais de diferentes módulos de elasticidade, em pré-molares submetidos a carregamento oclusal excêntrico / Marginal quality of cervical restorations, made with materials of different moduli of elasticity, in premolars subject to eccentric occlusal loadingAnhesini, Brunna Haddad 01 July 2016 (has links)
Os materiais restauradores utilizados na região cervical dos dentes podem ser afetados por resultantes de forças oclusais excêntricas, que já podem ter contribuído à formação da lesão, e deveriam ser capazes de resistir às tensões. Não há consenso, porém, quanto ao papel de diferentes materiais, quiçá especialmente no tocante a seus módulos de elasticidade, no sucesso das respectivas restaurações. Avaliou-se, pois, a influência do uso desses materiais, com módulos de elasticidade (E) distintos em essência, e da associação entre eles, na qualidade marginal de restaurações cervicais em pré-molares submetidos a carregamento oclusal excêntrico. Cavidades cervicais em forma de cunha, preparadas em pré-molares unirradiculares superiores humanos, hígidos e extraídos, foram restauradas com uma resina composta (RC: Z250 XT, n=20); com a resina em associação a um ionômero modificado por resina para forramento (Mista/M: Vitrebond, n=20); ou com um ionômero modificado por resina para restauração (CIV: Vitremer, n=20). Metade dos dentes de cada grupo foi submetida a carregamento oclusal excêntrico (coe: inclusão em resina acrílica e ligamento periodontal artificial, 150 N, 106 ciclos, 2,5 Hz), e a outra metade, apenas armazenada por período de tempo equivalente (Controle/c: água destilada, 37º C). Um sistema adesivo marcado por fluoresceína foi utilizado para delimitação dos defeitos formados, que foram avaliados por meio de Microscopia Confocal de Varredura a Laser. Para a presença ou ausência de fendas marginais aplicou-se, num contexto geral, para cada fator em estudo (carregamento oclusal excêntrico - coe / c; material restaurador - RC / M / CIV), o teste do qui-quadrado (?=0,05). Em específico, aplicaram-se, individualmente, em cada nível do fator carregamento oclusal excêntrico, e em cada nível do fator material restaurador, respectivamente, o teste do qui-quadrado e o teste exato de Fisher (?=0,05). Para a localização das fendas em relação às paredes cavitárias (O: oclusal / C: cervical / OC: ambas) aplicou-se, para cada fator em estudo, o teste do qui-quadrado (?=0,05). O teste de Mann-Whitney foi aplicado para a largura e a profundidade das fendas marginais, para comparar os diferentes níveis do fator carregamento oclusal excêntrico, e o teste de Kruskal-Wallis, para comparar os diferentes níveis do fator material restaurador (?=0,05). Numa conjuntura abrangente, nenhum dos fatores associou-se significativamente com as variáveis de resposta qualitativas nominais ou exerceu influência sobre as quantitativas. Mais especificamente, por exclusivo quando da aplicação do carregamento oclusal excêntrico, o uso dos diferentes materiais restauradores associou-se significativamente com a frequência de fendas marginais (RC>M>CIV). Ainda que a qualidade marginal de restaurações cervicais possa não ser influenciada, de maneira geral, pelo carregamento oclusal ou pelo uso de diferentes materiais, inclusive em associação, o aspecto desfavorável do emprego da resina composta pode tornar-se relevante, em particular, quando da existência de carga oclusal excêntrica. / Restorative materials used in the cervical region of teeth may be impacted by resultants of eccentric occlusal loads that have already contributed to the formation of the lesion, and should be capable of withstanding the stresses. There is no consensus, however, about the role of different materials, maybe especially regarding their moduli of elasticity, in the success of respective restorations. The influence of the use of these materials, with different moduli of elasticity (E) in essence, and of their association, on marginal quality of cervical restorations in premolars subjected to eccentric occlusal loading was evaluated thus. Cervical wedge-shaped cavities, prepared in human upper single-rooted premolars, healthy and extracted, were restored with a resin composite (RC: Z250 XT, n=20); with the composite in combination with a resin-modified lining ionomer (Mixed/M: Vitrebond, n=20), or with a resin-modified restorative ionomer (GIC: Vitremer, n=20). Half of the teeth of each group was subjected to eccentric occlusal loading (eol: embedment in acrylic resin, artificial periodontal ligament, 150 N, 106 cycles, 2.5 Hz), and the other, only stored for an equivalent period of time (Control/c: distilled water, 37°C). A fluorescein-marked adhesive system was used for delimitation of formed defects, which were evaluated by means of Laser Scanning Confocal Microscopy. For the presence or absence of marginal gaps, in a general context and for each factor under study (eccentric occlusal loading - eol / c; restorative material - RC / M / GIC), chi-square test was applied (?=0.05). In specific, individually, at each level of the factor eccentric occlusal loading, and at each level of the factor restorative material, chi-square test and Fisher\'s exact test were respectively applied (?=0.05). For the location of the gaps in relation to the cavity walls (O: occlusal / C: cervical / OC: both), for each factor under study, chi-square test was applied (?=0.05). The Mann-Whitney test was applied to the width and depth of marginal gaps, to compare the different levels of the factor eccentric occlusal loading, and the Kruskal-Wallis test, to compare the different levels of the factor restorative material (?=0.05). In a comprehensive view, none of the factors was significantly associated with qualitative response variables or wielded any influence on the quantitative ones. More specifically, for exclusive when eccentric occlusal loading was applied, the use of the different restorative materials was significantly associated with the frequency of marginal gaps (RC>M>GIC). Though marginal quality of cervical restorations may not be in general influenced by the occlusal loading or the use of different materials, even in association, the unfavorable aspect of the use of the resin composite may become relevant particularly in face of the existence of eccentric occlusal load.
|
54 |
Avaliação de dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e barra articulada / Evaluation of two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated BarSilva, Rafael Cândido Pedroso e 27 January 2016 (has links)
O objetivo deste estudo foi avaliar dois diferentes planejamentos de próteses totais fixas implantossuportadas, comparando as técnicas de fabricação das infraestruturas: tecnologia CAD-CAM, fundição convencional e Barra Articulada. Após ciclagem termomecânica, foram analisadas a perda de torque dos parafusos protéticos e adaptação marginal vertical e horizontal. Ao final, as próteses foram submetidas a ensaios de fadiga acelerada progressiva e resistência à fratura. Foram confeccionadas 48 próteses totais fixas implantossuportadas, as quais foram divididas inicialmente em dois grupos, G1 protocolo convencional; G2 - “All-on-4”. De acordo com a técnica de fabricação das infraestruturas, estes grupos foram divididos em três subgrupos, A - tecnologia CAD-CAM; B - fundição convencional; C - Barra Articulada, proporcionando seis amostragens diferentes: G1A, G1B, G1C, G2A, G2B e G2C (n=8). Todas as próteses foram avaliadas em relação à adaptação marginal vertical e horizontal, utilizando MicroCT, antes e após a ciclagem termomecânica (2.000.000 de ciclos). A perda de torque dos parafusos protéticos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). Após este ensaio, as próteses foram submetidas ao teste de fadiga acelerada progressiva (n=8) e em sequência, ensaio de resistência à fratura (n=6). A perda de torque teve diferença significante para todos os tempos comparados (p<0,01), exceto em G2B, onde a comparação entre T1 - T2 não mostrou diferença significante (p=0,72). A comparação entre G1 e G2 não foi significante. A comparação entre os subgrupos A, B e C teve diferenças significantes em G1T1, G1T2, G2T1 e G2T2 quando comparados os subgrupos A - B e B - C, todos com (p<0,01). Não houve diferenças significantes para a adaptação marginal vertical e horizontal antes e depois da ciclagem em todos os grupos. Na comparação de G1 e G2, houve diferença significante para a adaptação vertical e horizontal apenas no subgrupo B, nos dois tempos, ambos com (p <0,01). Na comparação dos subgrupos A, B e C, houve diferenças significantes em G1 antes e depois; e G2 antes e depois, quando comparados os subgrupos A - B e B - C, todos com (p<0,01) para a adaptação vertical e horizontal. Já para a adaptação horizontal, esta comparação foi significante apenas em G2 antes e depois, ambos com (p=0,02). Em relação à resistência à fratura, a comparação entre G1 e G2, foi significante em todos os subgrupos, A e C (p<0,01), B (p=0,02). A comparação dos subgrupos A, B e C, também foi significante em relação à resistência à fratura das próteses em todos os grupos (p<0,01). Pode-se concluir que a simulação de ciclos mastigatórios teve influência significante sobre a perda de torque dos parafusos protéticos, porém não influenciou significativamente a adaptação marginal vertical e horizontal das próteses; desadaptações marginais influenciaram significativamente no afrouxamento dos parafusos protéticos; as próteses dos subgrupos A e C obtiveram resultados significantemente melhores para a adaptação marginal vertical e horizontal quando comparadas às do subgrupo B, sendo que na adaptação horizontal, as do subgrupo A tiveram resultados melhores que as do C; a quantidade e distribuição dos implantes não influenciou na perda de torque dos parafusos protéticos em todas as situações, porém teve influência significativa na adaptação marginal vertical e horizontal das próteses do subgrupo B; todas as próteses sobreviveram ao ensaio de fadiga acelerada progressiva; em relação ao ensaio de resistência à fratura, as próteses do G2, tiveram resultados significantemente melhores que as do G1, o subgrupo B obteve valores significantemente maiores de resistência na região do cantilever, quando comparadas ao subgrupos A e C; o subgrupo A obteve os menores valores de resistência. / The objective of this study was evaluate two different designs of full-arch implant-supported fixed dentures, comparing the infrastructure manufacturing techniques: CAD-CAM technology, conventional casting and Articulated Bar. After thermomechanical cycling, were analyzed prosthetic screws loosening and vertical and horizontal marginal adaptation. In the end, the prostheses were submitted to tests of progressive accelerated fatigue and fracture resistance. Were made 48 implant-supported fixed dentures, which initially were divided into two groups, G1 - conventional protocol; G2 - \"All-on-4\". According to the technique of manufacturing infrastructure, these groups were divided into three subgroups: A - CAD-CAM technology; B - conventional casting; C - Articulated bar, providing six different samples: G1A, G1B, G1C, G2A, G2B e G2C (n=8). All samples were evaluated in the vertical and horizontal marginal adaptation using MicroCT before and after the thermomechanical cycling (2,000,000 cycles). The loosening of the prosthetic screws was analyzed before (T0), 1,000,000 (T1) and 2,000,000 cycles (T2). After this test, the prostheses were submitted to progressive accelerated fatigue test (n = 8) and sequentially fracture resistance test (n = 6). The prosthetic screw loosening has significant difference for all time compared (p <0.01), except in G2B where the comparison between T1 - T2 showed no significant difference (p = 0.72). The comparison between G1 and G2 was not significant. The comparison between subgroups A, B and C had significant differences in G1T1, G1T2, G2T1 and G2T2 compared subgroups A - B, B - C, all of (p <0.01). There were no significant differences for vertical and horizontal marginal adaptation before and after cycling in all groups. Compared to G1 and G2, there was a significant difference for vertical and horizontal adjustment only in the subgroup B in two stages, both (p <0.01). In the comparison of subgroups A, B and C, there were significant differences G1 before and after; and G2 before and after, when compared subgroups A - B, B - C, all of (p <0.01) for vertical and horizontal adaptation. As for the horizontal adaptation, this comparison was significant only in G2 before and after, with both (p = 0.02). With regard to fracture resistance, the comparison between G1 and G2 was significant in all subgroups, A and C (p <0.01), B (p = 0.02). The comparison of subgroups A, B and C was also significant compared to the fracture resistance of the prosthesis in all groups (p <0.01). It can be concluded that the simulation of mechanical cycling had significant influence on the loosening of prosthetic screws, but did not significantly influence the vertical and horizontal marginal fit of the prosthesis; marginal adaptation significantly influenced the loosening of prosthetic screws; the prostheses of the subgroups A and C had significantly better results for the vertical and horizontal marginal adaptation when compared to the subgroup B, and in the horizontal adaptation, the sub-group A had better results than those of C; the amount and distribution of the implants did not affect the prosthetic screws loosening in all situations, but had significantly influence in vertical and horizontal marginal adaptation of subgroup B prostheses; all samples survived in progressive accelerated fatigue test; in relation to the fracture resistance test, the prosthesis G2, had significantly better results than the G1, the B subgroup achieved significantly higher values of resistance in the cantilever region, when compared to subgroups A and C; the subgroup C obtained the smallest resistance.
|
55 |
Microinfiltração e adaptação marginal de restaurações classe V simulando lesões de abfração / Microleakage and marginal adaptation of class v restorations simulating the abfraction lesionsPereira, Adriana de Fátima Vasconcelos 10 December 2007 (has links)
Avaliou-se in vitro restaurações classe V, simulando a configuração cavitária de lesões de abfração, quanto à microinfiltração e adaptação marginal. Sessenta pré-molares superiores foram divididos em seis grupos (n = 10), variando a combinação restauradora: G1 = Ketac Molar Liquid/Ketac Molar Easymix, G2 = Primer/Vitremer, G3 = Adper Single Bond 2/Durafill, G4 = Adper Single Bond 2/Z100, G5 = Clearfil SE Bond/Durafill e G6 = Clearfil SE Bond/Z100. Réplicas à base de resina poliéster foram obtidas como controle positivo para avaliação da adaptação após os ensaios laboratoriais. Todos os dentes foram submetidos à ciclagem térmica (1000 ciclos/5º-55ºC), ciclagem mecânica (100.000 ciclos/8kgf) e imersos em solução aquosa de azul de metileno 0,5% (pH 7,2) por 4h. Os espécimes foram seccionados longitudinal e transversalmente, obtendo-se duas partes. O grau de microinfiltração foi avaliado através de dois métodos, um qualitativo, por meio de escores atribuídos por três observadores, e outro quantitativo, usando o software Imagelab 2000. A análise de elementos finitos foi realizada para verificar a concentração de tensões na região cervical por meio da confecção de três modelos 3D de pré-molares, com o objetivo de representar o ensaio de ciclagem mecânica. Os resultados tratados pelo teste Kruskal-Wallis mostraram diferença estatística significativa (p < 0,05) para a margem em dentina, obtendo os menores valores de microinfiltração em ambos os métodos para G2, G5 e G6, respectivamente. Não houve diferença significante para a margem em esmalte. Para a adaptação marginal, os achados não revelaram diferença estatisticamente significante entre os substratos dentários (p < 0,05). O coeficiente de Spearman demonstrou correlação direta entre os métodos de avaliação para esmalte e dentina (p < 0,0001). As freqüências de ocorrência de desadaptação marginal foram comparadas pelo teste do Qui-quadrado para esmalte e dentina. Os dados não demonstraram diferença estatisticamente significante. A análise de elementos finitos constatou maior concentração de tensões de tração na dentina radicular no mesmo lado da aplicação da carga e no modelo restaurado com Z100. Concluiu-se que o cimento de ionômero de vidro modificado por resina, seguido das combinações restauradoras Clearfil SE Bond/Z100 e Clearfil SE Bond/Durafill VS, são os mais indicados para restaurações em áreas de abfração quando comparados aos outros materiais testados. / This in vitro study evaluated class V restorations simulating the wedge-shaped lesions as a function of the microleakage and marginal adaptation. Sixty upper premolars were divided into six groups (n = 10) using such restorative combinations: G1 = Ketac Molar Liquid/Ketac Molar Easymix, G2 = Primer/Vitremer, G3 = Adper Single Bond 2/Durafill, G4 = Adper Single Bond 2/Z100, G5 = Clearfil SE Bond/Durafill, G6 = Clearfil SE Bond/Z100. The poliester resin replicas were obtained as positive control for adaptation assessment after laboratory essays. All the teeth were subjected to thermocycling (1000 cycles/5°-55°C), mechanical load cycling (100.000 cycles/8Kgf), and immersed in 0,5% methylene blue dye (pH 7,2) for 4 hours. Then the specimens were sectioned longitudinally and transversally to obtain two parts of them. The microleakage degrees were assessed by qualitative and quantitative methods. The finite element analysis was performed in order to verify stress concentration at the cervical region. For this purpose, three 3D finite element models of premolars were created and then compared to mechanical load cycling. The results were submitted to Kruskal-Wallis test being statistically significant for the cervical dentin margin with lower microleakage values in both methods for G2, G5 and G6, respectively (p < 0, 05). The cervical enamel margin had no significant difference for microleakage values. For marginal adaptation, there was no statistically difference among the substrates (p < 0, 05). Spearman coefficient has showed a direct correlation between enamel and dentin (p < 0, 0001). The frequency of loss of marginal fit was calculated by Qui-square test. The data have shown no significant difference. The finite element analysis has presented higher tensile stresses at the root dentin at the same side of load direction and in the model restored by Z100. It has concluded that resin-modified glass ionomer cements, followed by Clearfil SE Bond/Durafill and Clearfil SE Bond/Z100 are the most indicated dental materials to restore abfraction lesions with comparison to other ones tested.
|
56 |
Avaliação da desadaptação marginal de estruturas metálicas obtidas com variações quanto aos tipos de cera e às técnicas de inclusão e fundiçãoMarchiori, André Vinícius [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2004Bitstream added on 2014-06-13T20:18:36Z : No. of bitstreams: 1
marchiori_av_me_araca.pdf: 946522 bytes, checksum: ed4cd9e55e14d7d9431de58e44b8da02 (MD5) / Cng Solucoes Proteticas / Talladium do Brasil / O objetivo deste trabalho foi observar o comportamento de ceras para fundições, utilizando a técnica de fundição convencional, comparando-a a técnica de fundição rápida; utilizando em ambas a expansão higroscópica de um revestimento fosfatado (All Therm, CNG Soluções Protéticas). Utilizamos duas ceras: Cera para imersão GALILEO Dip Pot Wax (Talladium Inc.) e Cera Azul para fresagem (CNG Soluções Protéticas), que foram submetidas às duas técnicas de fundição propostas. Cada grupo experimental foi composto por 12 corpos de prova e, a verificação do desajuste marginal foi realizada através de um microscópio comparador digital Mitutoyo. Cada corpo de prova foi medido em quatro pontos pré-determinados no troquel metálico. A análise dos resultados demonstrou que, com a metodologia empregada, a técnica de fundição rápida apresentou desempenho favorável, quando comparado com a técnica convencional para ambas as ceras; e a cera Azul para fresagem, na técnica rápida, foi a que apresentou menor valor médio de desadaptação (sub-adaptação). Concluímos que utilizar a expansão higroscópica do revestimento fosfatado foi uma forma de viabilizar a técnica de fundição rápida, obtendo resultados favoráveis com ambas as ceras. / The purpose of this investigation was to observe and evaluate the behavior of dental casting wax in conventional and accelerated casting techniques, both using hygroscopic expansion of phosphate bonded investment, in order to determine which material or technique would provide better results about cervical fitting in the obtained metallic structure. The two casting waxes used, GALILEO Dip Pot Wax (Talladium Inc.) and Blue Wax of milling (CNG Soluções Protéticas), were submitted to both proposed casting techniques. Each experimental group was consisted of twelve specimens and, the assessment of marginal fitting was performed by means of a Mitutoyo comparator microscope. Each specimen was measured by using four pre-established points in stainless steel master die as references. From the employed methodology the analysis of the results showed that accelerated casting technique presented superior fitting in comparison with the conventional technique for both types of waxes. Besides, in the accelerated casting technique the Blue Wax of milling presented smaller mean value of unadaptation (underadaptation). We conclude that the use of the hygroscopic expansion of phosphate bonded investment was a way to viable the accelerated casting technique, obtaining favorable results with both casting waxes.
|
57 |
Comparação da desadaptação marginal de infra-estruturas metálicas obtidas com variações na técnica de fundição, revestimentos e material para obtenção dos padrõesZequetto, Michele Marques [UNESP] 07 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-12-07Bitstream added on 2014-06-13T20:37:53Z : No. of bitstreams: 1
zequetto_mm_me_araca.pdf: 764308 bytes, checksum: f9f1ab6ade3df1b1023440b60d0137eb (MD5) / Pro-Line Servicos Produtos Odontologicos Ortopedicos Ltda. / O presente trabalho avaliou a desadaptação marginal de infra-estruturas metálicas de coroas metalo-cerâmicas obtidas com técnicas de fundição convencional (T1) e rápida (T2), utilizando para inclusão os revestimentos: aglutinado por fosfato Termocast (R1) e a base de cerâmica granulada Micro Fine 1700 (R2), confeccionando padrões em cera escultura Galileo (P1) e padrões em resina acrílica Duralay (P2), com n=56, sobre um troquel metálico. Para a construção dos padrões, utilizou-se uma matriz de silicone e realizou-se a fundição com liga de Ni-Cr. Verificou-se a desadaptação marginal por meio de um microscópio comparador digital Mitutoyo em 12 diferentes pontos de cada infra-estrutura. Os dados obtidos foram submetidos à análise de variância (ANOVA) e teste de Tukey com p<0.05, demonstrando os menores valores de desadaptação marginal e, estatisticamente similares (p<0.05), em ordem crescente, para os grupos: P2R2T2 (55,4æm), P2R1T2 (55,6æm), P2R1T1 (57,4æm), P1R2T2 (59,4æm), P1R2T1 (86æm), P1R1T1(104,4æm); e os maiores valores para P1R1T2 (166,9æm) e P2R2T1 (185,3æm). Os resultados obtidos permitiram concluir que as infra-estruturas metálicas obtidas com padrões, tanto de cera quanto de resina acrílica, apresentaram valores aceitáveis em ambas as técnicas de fundição realizadas, desde que as interações e recomendações dos fabricantes dos revestimentos sejam respeitadas. / The present study evaluated the marginal unfit of metallic infrastructures of metallic-ceramic crowns obtained through the conventional (T1) and accelerated (T2) casting techniques, using for investing the investments: agglutinated by phosphate Termocast (R1) and the base of granulated ceramic Micro Fine 1700 (R2), making patterns in sculpture wax Galileo (P1) and patterns in acrylic resin Duralay (P2), with n=56, on a metallic die with shoulder in chamfer. For the construction of the patterns, a matrix of silicone was used and the casting was made with Ni-Cr alloy. The marginal unfit was verified through the comparing microscope Mitutoyo in 12 different points of each infrastructure. The values obtained were submitted to analysis of variance (ANOVA) and Tukey s test with p<0.05, showed smaller values and statistically similar, in increasing order, for the groups: P2R2T2 (55,4ìm), P2R1T2 (55,6ìm), P2R1T1 (57,4ìm), P1R2T2 (59,4ìm), P1R2T1 (86ìm), P1R1T1(104,4ìm); and the largest values for P1R1T2 (166,9ìm) and P2R2T1 (185,3ìm). Taking obtained results into account, it was possible to conclude that the metallic infrastructures obtained from patterns, of wax as well as of acrylic resin, presented acceptable values of marginal fit in both casting techniques, providing the interactions and the recommendations of the investments manufacturers are respected.
|
58 |
Comparação da adaptação cervical de estruturas metálicas para metalo-cerâmica obtidas através de técnica de fundição rápida e convencional, utilizando três revestimentos comerciaisYamaguti, Paulo Fukashi [UNESP] January 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2002Bitstream added on 2014-06-13T19:58:25Z : No. of bitstreams: 1
yamaguti_pf_dr_araca.pdf: 1303704 bytes, checksum: c56df7e24d39dbb84e5211b463f57dd7 (MD5) / Rotineiramente, o processo de fundição odontológica envolve um tempo de espera de até três horas, porém, os novos revestimentos permitem que este seja realizado em aproximadamente 40 minutos, inclusive com ganho de qualidade. Um destes revestimentos é aglutinado por fosfato melhorado e outro é cerâmico. Pelo fato de não encontrarmos dados comparativos a respeito destes novos materiais, realizamos um estudo, verificando a sua eficácia frente à técnica de fundição rápida e a técnica de fundição convencional, comparando qual proporciona melhores resultados de adaptação cervical das estruturas metálicas obtidas. Utilizamos três revestimentos: Termocast (Polidental), Heat Shock (Polidental) e o Micro Fine 1700 (Talladium Inc.), que foram submetidos às duas técnicas propostas e cada grupo experimental foi composto por 5 corpos de prova. A verificação do desajuste cervical foi realizada através de um microscópio comparador digital. Cada corpo de prova foi medido em 4 pontos pré-determinados (V, L, M e D). A análise dos resultados demonstrou que a técnica de fundição rápida apresentou desempenho desfavorável, quando comparados com a técnica convencional para um mesmo revestimento, e a melhor adaptação; tanto na técnica de fundição convencional, como na rápida, foi a do revestimento cerâmico. Concluímos que a técnica de fundição rápida é viável para o revestimento cerâmico, mas é preciso obter resultados favoráveis também aos outros revestimentos, antes de se abandonar a técnica de fundição convencional. / Routinely, an up to three hours of waiting time is expected for dental casting process, however, new investments materials allow that this process may be performed in approximately forty minutes besides the improvement in the quality. One of the investments is agglutinated with improved phosphate and the other with ceramics. Due to the scarcity of comparative data regarding to these new materials, this study was performed to verify their behavior in accelerated and conventional casting techniques with the aim of finding out which material would provide better results of cervical fitting in the obtained metallic infra-structure. Three investments, Termocast (Polidental), Heat Shock (Polidental) and Micro Fine 1700 (Talladium, Inc.), were used, which were submitted to both casting techniques. Each experimental group was constituted by five specimens. The assessment of cervical fitting was performed by means of a comparator microscope. Each specimen was measured by using four pre-established points (V, L, M and D) as references. The results analysis showed that, for the same investment, accelerated casting technique presented worst fitting in comparison with the conventional technique, and best fitting, in both the conventional and accelerated techniques, was showed by ceramics investment. We conclude that the accelerated technique is viable for ceramic investment, but favorable results are needed with regard to other investments before the substitution of the conventional technique by the accelerated one.
|
59 |
Avaliação da adaptação marginal de restaurações cerâmicas inlay após a cimentaçãoCarvalho, Cristiane Fonseca de [UNESP] 19 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-06-19Bitstream added on 2014-06-13T20:58:53Z : No. of bitstreams: 1
carvalho_cf_me_sjc.pdf: 1809025 bytes, checksum: bd4ee4f9a60dfdd8304d67de208703e4 (MD5) / O objetivo deste estudo foi avaliar e comparar a adaptação marginal de restaurações, confeccionadas em dois tipos de sistemas cerâmicos: CEREC inLab (VITA) e IPS Empress 2 (Ivoclar-Vivadent) , após a cimentação com cimento resinoso RelyX (3M). Foram preparados 20 pré-molares humanos com cavidade MOD inlay, reproduzidos com silicone de adição, e obtidos modelos em gesso tipo IV, sobre os quais foram confeccionadas as restaurações conforme as recomendações dos fabricantes. Dez inlays no sistema IPS Empress 2 e 10 inlays no sistema CEREC inLab. As restaurações foram cimentadas sob pressão constante de 1,5 Kgf por 10 min, com cimento resinoso, com pré-tratamento. As desadaptações marginais foram avaliadas em MEV, com magnificação de 200x, em 50 pontos eqüidistantes. As médias foram analisadas pelo teste estatístico t(Student) de amostras dependentes.Resultando em uma diferenca estatisticamente significante entre as desadaptaçoes marginais no sistema IPS Empress (93,8'mais ou menos'15,5'mü'm)que se mostraram menores que no sistema CEREC inLab (114,4'mais ou menos'10,6'mü'm). Quando se comparou os valores médios entre as faces proximais (116,51.21,85'mü') e oclusal (112,26'mais ou menos'8,49'mü) do sistema Cerec Inlab, e faces proximais (87,12'mais ou menos'27,98,'mü') e oclusal (100,47'mais ou menos'22,23'mü')do sistema IPS Empress 2, verifica-se que esses valores não diferem estatisticamente. Ainda assim, conclui-se que as médias obtidas são aceitavéis clinicamente. / This study has the proposal to evaluate the marginal adaptation of two system all-ceramic class II inlays one of laboratory-made heat-pressed ceramics (IPS Empress 2) and other computer-aided manufacturing ( CEREC inLab) after cementation with resin cement . Extracted human premolars were prepared to receive mesio occluso distal (MOD) ceramic inlays for 10 IPS Empress restorations and 10 CEREC inLab restorations. The impression material used was a polivinilsyloxane addition silicone by the double impression technique. The impressions of prepared teeth were cast in type IV dental stone. The restaurations were made following the manufacturer's recommendations. The inlays were luted on human premolars with resin cement in accordance with the manufacturer's recommended pré-treatment. The marginal gaps were investigated scanning electron microscopy with magnification of 200x. The results were analyzed by t (student) statistic test.The means marginal gap for IPS Empress 2 wal 93,8'mais ou menos'15,5'mü'm significantly smaller than that od 114,4'mais ou menos'10,6'mü'm calculated a the CEREC in Lab system.The gaps of the inlays at the occlusal margin and of the approximal margin showed no significantly differences in two system. It may be concluded that mensuarement value are clinically acceptable.
|
60 |
Desajuste interno e desadaptação marginal de sistemas restauradores estéticos usados em restaurações inlays indiretas / Quantification of internal gap and marginal leakage área of aesthetic restorations systems used in indirect inlaysGleidson Rocha Arouca 09 December 2009 (has links)
O objetivo é comparar o ajuste interno e marginal cervical de dois sistemas de compósito e um de cerâmica prensada. O Material e Métodos foi elaborado a partir de um modelo mestre metálico com preparo para inlay MOD, 15 troquéis de gesso tipo IV foram obtidos e distribuídos randomicamente em três grupos (n=5), a saber: Grupo Empress, Grupo Sinfony e Grupo Z350. Após a confecção das restaurações, cada peça foi posicionada no modelo mestre e fotografada nas faces mesial e distal para através de um programa de computador fazer a análise da desadaptação marginal cervical. Depois, a peça foi cimentada no modelo mestre usando silicone de adição de ultrabaixa viscosidade para preencher o espaço entre as restaurações e o preparo. Após a remoção das inlays, cada réplica foi pesada em balança de precisão para posterior obtenção de seu volume. Nos Resultados temos a interface paredes do preparo/paredes da restauração: houve diferença estatística entre o grupo Empress, que apresentou volume até 137% maior que os demais grupos, que foram considerados iguais entre si. Área de desadaptação marginal cervical: Houve diferença entre todos os grupos com o grupo Empress apresentando os maiores valores, seguido pelo grupo Sinfony e pelo grupo Z350. Os grupos Empress e o Sinfony apresentaram respectivamente áreas de desadaptação 450% e 200% maiores que o grupo Z350. Maior distância entre as bordas da restauração e as margens do preparo os grupos Empress e Sinfony foram iguais estatisticamente e diferentes do grupo Z350 que apresentou os menores valores. Entretanto, o grupo Empress apresentou uma desadaptação linear 43% maior que o grupo Sinfony. Concluímos que quanto ao desajuste interno, o grupo Empress apresentou os maiores valores no volume da interface dente/restauração, com diferença estatística significativa (P<0,05) em relação aos demais grupos. Para o cálculo da área, a desadaptação marginal foi menor no grupo Z350, seguido dos grupos Sinfony e Empress, todos mostrando diferença estatística significativa entre si (P<0,05). Considerando a medida linear, a desadaptação marginal foi menor no grupo Z350, indicando diferença estatística significativa (P<0,05) deste para os demais grupos. / The objective is to compare the internal and marginal cervical adjustment of two systems of composite and another of pressed ceramic. The material and methods was made based on a metal pattern model with inlay MOD preparation, 15 plaster casts type IV were obtained and randomly distributed into three groups (n=5) as it follows: Empress Group, Sinfony Group, Z350 Group. After restorations were made, each piece was positioned in the pattern model and had its middle and distal faces photographed in order to analyze marginal cervical ill-fitting through a computer software program. Then the piece was cemented to the pattern model using ultra-low viscosity silicone to fill in the spaces between restoration and preparation. After removing the inlays, each replica was precisely weighed for future volume consideration. As results we have the preparation surface / restoration surface interface: there was statistical difference between the Empress Group and the other groups. While both the Sinfony and the Z350 Group had similar results, the Empress Group presented a volume 137% higher. Cervical Marginal ill-fitted area: all the three groups presented different outcome: the Empress Group presented the highest values, followed by the Sinfony and the Z350. The Empress and the Sinfony presented, respectively, ill-fitted area 450 and 200 times higher than Group Z350. Longest distance between restoration and preparation edges: Both the Empress and the Sinfony had similar statistical results, which were higher than the values presented by Z350 Group. Nevertheless, the Empress Group presented a linear lack of adaptation 43% higher than the Sinfony. We Concluded that Group Empress presented the best values of all evaluations while Group Z350 had the worst results. As long as inner and marginal cervical adaptations are concerned, results point Z350 as the most reliable group.
|
Page generated in 0.1012 seconds