• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 81
  • 81
  • 62
  • 52
  • 31
  • 19
  • 16
  • 15
  • 15
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Qualidade marginal de restaurações cervicais, feitas com materiais de diferentes módulos de elasticidade, em pré-molares submetidos a carregamento oclusal excêntrico / Marginal quality of cervical restorations, made with materials of different moduli of elasticity, in premolars subject to eccentric occlusal loading

Brunna Haddad Anhesini 01 July 2016 (has links)
Os materiais restauradores utilizados na região cervical dos dentes podem ser afetados por resultantes de forças oclusais excêntricas, que já podem ter contribuído à formação da lesão, e deveriam ser capazes de resistir às tensões. Não há consenso, porém, quanto ao papel de diferentes materiais, quiçá especialmente no tocante a seus módulos de elasticidade, no sucesso das respectivas restaurações. Avaliou-se, pois, a influência do uso desses materiais, com módulos de elasticidade (E) distintos em essência, e da associação entre eles, na qualidade marginal de restaurações cervicais em pré-molares submetidos a carregamento oclusal excêntrico. Cavidades cervicais em forma de cunha, preparadas em pré-molares unirradiculares superiores humanos, hígidos e extraídos, foram restauradas com uma resina composta (RC: Z250 XT, n=20); com a resina em associação a um ionômero modificado por resina para forramento (Mista/M: Vitrebond, n=20); ou com um ionômero modificado por resina para restauração (CIV: Vitremer, n=20). Metade dos dentes de cada grupo foi submetida a carregamento oclusal excêntrico (coe: inclusão em resina acrílica e ligamento periodontal artificial, 150 N, 106 ciclos, 2,5 Hz), e a outra metade, apenas armazenada por período de tempo equivalente (Controle/c: água destilada, 37º C). Um sistema adesivo marcado por fluoresceína foi utilizado para delimitação dos defeitos formados, que foram avaliados por meio de Microscopia Confocal de Varredura a Laser. Para a presença ou ausência de fendas marginais aplicou-se, num contexto geral, para cada fator em estudo (carregamento oclusal excêntrico - coe / c; material restaurador - RC / M / CIV), o teste do qui-quadrado (?=0,05). Em específico, aplicaram-se, individualmente, em cada nível do fator carregamento oclusal excêntrico, e em cada nível do fator material restaurador, respectivamente, o teste do qui-quadrado e o teste exato de Fisher (?=0,05). Para a localização das fendas em relação às paredes cavitárias (O: oclusal / C: cervical / OC: ambas) aplicou-se, para cada fator em estudo, o teste do qui-quadrado (?=0,05). O teste de Mann-Whitney foi aplicado para a largura e a profundidade das fendas marginais, para comparar os diferentes níveis do fator carregamento oclusal excêntrico, e o teste de Kruskal-Wallis, para comparar os diferentes níveis do fator material restaurador (?=0,05). Numa conjuntura abrangente, nenhum dos fatores associou-se significativamente com as variáveis de resposta qualitativas nominais ou exerceu influência sobre as quantitativas. Mais especificamente, por exclusivo quando da aplicação do carregamento oclusal excêntrico, o uso dos diferentes materiais restauradores associou-se significativamente com a frequência de fendas marginais (RC>M>CIV). Ainda que a qualidade marginal de restaurações cervicais possa não ser influenciada, de maneira geral, pelo carregamento oclusal ou pelo uso de diferentes materiais, inclusive em associação, o aspecto desfavorável do emprego da resina composta pode tornar-se relevante, em particular, quando da existência de carga oclusal excêntrica. / Restorative materials used in the cervical region of teeth may be impacted by resultants of eccentric occlusal loads that have already contributed to the formation of the lesion, and should be capable of withstanding the stresses. There is no consensus, however, about the role of different materials, maybe especially regarding their moduli of elasticity, in the success of respective restorations. The influence of the use of these materials, with different moduli of elasticity (E) in essence, and of their association, on marginal quality of cervical restorations in premolars subjected to eccentric occlusal loading was evaluated thus. Cervical wedge-shaped cavities, prepared in human upper single-rooted premolars, healthy and extracted, were restored with a resin composite (RC: Z250 XT, n=20); with the composite in combination with a resin-modified lining ionomer (Mixed/M: Vitrebond, n=20), or with a resin-modified restorative ionomer (GIC: Vitremer, n=20). Half of the teeth of each group was subjected to eccentric occlusal loading (eol: embedment in acrylic resin, artificial periodontal ligament, 150 N, 106 cycles, 2.5 Hz), and the other, only stored for an equivalent period of time (Control/c: distilled water, 37°C). A fluorescein-marked adhesive system was used for delimitation of formed defects, which were evaluated by means of Laser Scanning Confocal Microscopy. For the presence or absence of marginal gaps, in a general context and for each factor under study (eccentric occlusal loading - eol / c; restorative material - RC / M / GIC), chi-square test was applied (?=0.05). In specific, individually, at each level of the factor eccentric occlusal loading, and at each level of the factor restorative material, chi-square test and Fisher\'s exact test were respectively applied (?=0.05). For the location of the gaps in relation to the cavity walls (O: occlusal / C: cervical / OC: both), for each factor under study, chi-square test was applied (?=0.05). The Mann-Whitney test was applied to the width and depth of marginal gaps, to compare the different levels of the factor eccentric occlusal loading, and the Kruskal-Wallis test, to compare the different levels of the factor restorative material (?=0.05). In a comprehensive view, none of the factors was significantly associated with qualitative response variables or wielded any influence on the quantitative ones. More specifically, for exclusive when eccentric occlusal loading was applied, the use of the different restorative materials was significantly associated with the frequency of marginal gaps (RC>M>GIC). Though marginal quality of cervical restorations may not be in general influenced by the occlusal loading or the use of different materials, even in association, the unfavorable aspect of the use of the resin composite may become relevant particularly in face of the existence of eccentric occlusal load.
72

Adaptação marginal de restaurações em resina composta expostas a diferentes agentes clareadores / Marginal adaptation of resin composite restorations exposed to bleaching agents

Andréa Tami Abe 09 April 2018 (has links)
Este estudo teve como objetivo avaliar a adaptação marginal de restaurações em resina composta confeccionadas utilizando-se como agentes adesivos sistemas de diferentes estratégias de interação, expostas a agentes clareadores e submetidas a ciclagem mecânica, por meio de avaliação em tomografia por coerência óptica (OCT). Para este estudo foram utilizados 90 molares humanos hígidos recém-extraídos. Uma cavidade classe V foi confeccionada na face vestibular de cada dente com a margem oclusal localizada em esmalte e a margem cervical em cemento/ dentina. Os espécimes foram divididos em 3 grupos experimentais, de acordo com o sistema adesivo utilizado (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). As cavidades foram então preenchidas com a resina composta nanoparticulada Filtek Z350XT, e em seguida o acabamento e o polimento foram realizados. Os espécimes foram submetidos a duas ciclagens mecânicas, sendo a primeira antes e a segunda após o clareamento. Ao final da primeira ciclagem, os espécimes foram subdivididos em 3 grupos (n=10) de acordo com o tratamento realizado (controle - água destilada, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). As imagens em OCT das restaurações foram obtidas em 4 momentos diferentes (antes da primeira ciclagem, depois da primeira ciclagem, após o tratamento e depois da segunda ciclagem). A interface dente-restauração foi analisada de duas formas, por meio de classificação das fendas por escore e mensuração da profundidade da fenda em micrômetros (?m), para esmalte e dentina separadamente. Os valores de escore foram analisados com o teste estatístico não-paramétrico de Kruskal-Wallis (p<0.05), e para os dados de profundidade de fenda em ?m, a ANOVA dois fatores (p<0.05) e teste de Tukey foram empregados. A correlação de Spearman foi empregada para correlacionar esses dois dados e foi observada uma correlação forte entre os dados de escore e de profundidade em ?m (r=0.85 p<0.0001). A comparação entre os grupos, tanto por escores quanto por profundidade em ?m, demonstraram que as fendas observadas após a primeira ciclagem foram estatisticamente maiores (p<=0.05) do que as fendas observadas inicialmente, exceto para a análise por escores, onde essa diferença foi detectada apenas para o adesivo SB2. O adesivo SBU apresentou as menores fendas marginais tanto em esmalte quanto em dentina. Em esmalte o adesivo CSE mostrou-se mais estável à degradação e em dentina não foi observada diferença estatisticamente significante entre os adesivos CSE e SB2. Entre os diferentes tratamentos, nenhuma diferença foi observada, independente do tempo de análise e do adesivo utilizado. Pode-se concluir que os clareadores utilizados não promoveram alteração da integridade marginal das restaurações em resina composta, sendo que as fendas marginais observadas estão mais relacionadas ao efeito do envelhecimento por ciclagem mecânica e são dependentes do sistema adesivo utilizado. Foi observada correlação direta entre os dois métodos de análise para mensuração da fenda marginal, contudo a análise da profundidade em ?m, utilizando teste paramétrico, mostrou-se mais sensível para a detecção de diferenças. / The aim of this study was to evaluate the marginal adaptation of resin composite restorations using different dental adhesive systems, exposed to dental bleaching agents and mechanical load cycling, by evaluation using optical coherence tomography (OCT). For this study 90 sound recently extracted human molars were used. One class V cavity was prepared in the buccal surface of each tooth with occlusal margin in enamel and cervical margin in dentin. The specimens were divided into 3 experimental groups, according to the adhesive system used (SB2: Single Bond 2, SBU: Single Bond Universal e CSE: Clearfil SE Bond). The cavities were restored with the nanocomposite Filtek Z350XT, and then the finishing and polishing were done. The specimens were submitted to two mechanical load cycling, the first one before bleaching and the second one after it. By the end of the first load cycling, the specimens were subdivided into 3 groups (n=10) according to the treatment accomplished (control - distilled water, HPB: Whiteness HP Blue - pH 8.8, PO: Pola Office - pH 3.6). The OCT images of the restorations were obtained in 4 distinct moments (before the first load cycling, after the first load cycling, after the treatment, and after the second load cycling). The tooth-restoration interface was analyzed by two ways: analyzing the gap by score and measurement of the gap depth in micrometer (?m), for enamel and dentin separately. The scores were analyzed with the non-parametric statistic test Kruskal-Wallis (p<0.05), and for the gap depth data, the two-way ANOVA (p<0.05) and Tukey test were used. The Spearman correlation were done to correlate these two data and a strong correlation between the score analysis an depth in ?m was observed (r=0.85 p<0.0001). The comparison between the groups, as by score as by depth in ?m, demonstrated that the gaps observed after the first load cycling were statistically deeper (p<=0.05) than the gaps observed initially, except for score analysis, when this difference was detected only for the adhesive SB2. The adhesive SBU showed less deep marginal gaps both in enamel and dentin. In enamel, the adhesive CSE was more stable to degradation and in the dentin no statistically difference was observed between the adhesives CSE and SB2. Between the different treatments, no difference was observed, regardless the evaluation time and the dental adhesive used. In conclusion, the bleaching agents used in this study did not affect the marginal integrity of resin composite restorations, thus the marginal gaps observed were more related to the aging by mechanical load cycling and were dependent of the dental adhesive system used. There was a direct correlation between both methods for marginal gap analysis, however the depth in ?m analysis, using parametric statistical test, showed more sensitive to detect differences.
73

Comparación in vitro de la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado / In vitro comparison of the marginal adaptation of ceramic glass porcelain crowns manufactured with three processing systems

Zegarra Cavero-Blumenfeld, Fernanda, Meza Huamán, Katya Valeria 02 December 2020 (has links)
Objetivo: Comparar in vitro la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado. Materiales y métodos: El presente estudio fue de tipo experimental in vitro. La muestra estuvo conformada por 69 coronas de porcelana vitrocerámica fabricadas con los sistemas: CAD-CAM, inyección de porcelana y condensación sobre muñón refractario. Para la evaluación de la discrepancia marginal vertical se realizó un registro fotográfico con una cámara digital y un lente macroscópico de 100 milímetros. Las imágenes fueron medidas digitalmente (ImageJ) y se utilizaron 52 puntos aleatorios de discrepancia marginal vertical alrededor de las coronas para obtener el promedio de cada una de ellas. Se utilizó la prueba de Kruskal-Wallis para realizar la comparación entre los grupos de estudio con un nivel de significancia estadística de p<0.05. Resultados: El presente estudio encontró diferencias estadísticamente significativas al comparar los tres sistemas de procesado (<0.001). El sistema CAD-CAM tuvo una discrepancia marginal vertical menor (53 µm) en comparación con el sistema de inyección de porcelana (85 µm) y el de condensación sobre muñón refractario (113 µm). Conclusiones: Se encontraron diferencias estadísticamente significativas entre los tres grupos de estudio. Asimismo, el sistema CAD-CAM tuvo una mayor adaptación marginal en comparación con los otros dos métodos de fabricación. Finalmente, los tres sistemas de confección utilizados tuvieron una discrepancia marginal vertical por debajo del límite establecido por la Asociación Americana de Odontología (<120 µm). / Objective: To compare in vitro the marginal adaptation of ceramic glass porcelain single crowns made with three processing systems. Materials and methods: The present study was experimental in vitro. The sample consisted of 69 glass ceramic porcelain crowns manufactured with the following three systems: CAD-CAM, porcelain injection and powder condensation. For de measurement of the vertical marginal discrepancy, the crowns were photographed using a digital camera with a macroscopic lens of 100 millimeters. The images were imported into image processing software (ImageJ) and 52 points were randomly selected around the crown to measure the vertical marginal discrepancy. For each crown, the 52 measurements were combined into a single average marginal discrepancy. Kruskal-Wallis was used to test differences in the observed marginal discrepancies between the study groups. (p <0.05) Results: This study found statistically significant differences when comparing the three different processing systems (<0.001). The CAD-CAM system had a smaller vertical marginal discrepancy (53 µm) compared to the porcelain injection (85 µm) and the powder condensation techniques (113 µm). Conclusions: Statistically significant differences were found between the three study groups. Also, the CAD-CAM system had a greater marginal adaptation compared to the other two manufacturing techniques. Finally, the three fabrication methods used in this study had a vertical marginal discrepancy within the limit established by the American Dental Association (<120 µm). / Tesis
74

Avaliação da adaptação de estruturas em Y-TZP entre diferentes sistemas CAD/CAM / Adaptation assessment of Y-TZP frameworks between different CAD / CAM systems

Koren, Andreas Raphael Ribas 04 March 2013 (has links)
OBJETIVOS: comparar dois sistemas CAD-CAM de diferentes gerações quanto ao grau de adaptação de infraestruturas estéticas de próteses fixas de três elementos para verificar se existe alguma evolução no quesito diminuição do gap marginal e se existe diferença de contração entre blocos de conformações diferentes que podem afetar diretamente a adaptação das mesmas. MATERIAL E MÉTODOS: para isso foi confeccionado um preparo de prótese fixa de três elementos em manequim odontológico simulando a ausência do elemento dental 25; posteriormente aos preparos foi reproduzido um modelo mestre em liga metálica Co-Cr para serem realizados os testes. O modelo mestre foi submetido a escaneamento em cada sistema comercial para a infraestrutura ser desenhada e fresada. Para serem confrontados, em cada sistema CAD/CAM foi confeccionado cinco infraestruturas em Y-TZP (n=5), sendo que no grupo CT1 foi utilizado um disco (ronde) com dimensões de 98x20 mm capaz de ser fresada até seis infraestruturas de uma só vez enquanto que no grupo CT2 cada infraestrutura foi confeccionada individualmente em um bloco com dimensões de 40x15x19 mm. Uma vez concluídas as infraestruturas, as mesmas foram submetidas a teste de adaptação com a técnica do dedal de silicone e posteriormente em cada preparo, tanto do molar quanto do pré-molar, foi retirada uma fatia de 2 mm de espessura em cada face (mesial, distal, lingual e vestibular) para se analisar a espessura de desadaptação na região de término através da análise de imagem (fotografia das fatias realizado por estereomicroscópio e medição com o software ImageJ). Os resultados foram submetidos aos testes de Normalidade e Homocedasticidade (p=0,05) e posteriormente analisados por ANOVA e Tukey (p=0,05). RESULTADOS: as medições foram divididas em dois grupos: 1. Adaptação geral ( medidas por face) e 2. Adaptação circunferencial (média das medidas das quatro faces). Em ambas as medições não houve diferenças estatisticamente significantes, permanecendo o gap marginal de ambos os materiais com resultados estatisticamente uniformes. CONCLUSÕES: ambos os sistemas CAD/CAM testados apresentaram resultados semelhantes e satisfatórios, dentro dos padrões clínicos aceitáveis e não houve diferença de contração de sinterização entre o disco (ronde) e o bloco. / OBJECTIVES: compare two CAD-CAM systems of different generations according to the adaptation level of three elements aesthetic FPD to discover if there are any changes in the item \"gap marginal decrease\" and if there is contraction differences between blocks of different conformations that may directly affect the adaptation. MATERIAL AND METHODS: it was made a FPD preparation (total crown preparation in each pillar tooth) in a dental mannequin, simulating the absence of the tooth 25; later was made a master template in Co-Cr alloy to be performed the tests, according to the mannequin preparations. The master model was subjected to scanning in each trading system to be designed the infrastructure and posteriorly milled. It was made five infrastructure in Y-TZP (n = 5) to be compared in every CAD / CAM system, and in the CT1 group was used a disc (ronde) with dimensions of 98x20 millimeters, where it can be milled up to six infrastructure of a once, while in the group CT2 each structure was fabricated into a single block with dimensions of 40x15x19 millimeters. After the infrastructure was milled, they were subjected to the adaptive technique of \"silicone replica\" and subsequently in each preparation (molar and premolar) was withdrawn from a 2 mm thickness slice on each side (mesial, distal, lingual and buccal) to analyze the mismatch thickness in the end region via image analysis (slices photography performed by a stereomicroscope and measured by the ImageJ software). The results were submited by Normality and Homoscedasticity test (p=0.05) and subsequently analyzed by ANOVA and Tukey test (p=0.05). RESULTS: the measurements were divided into two groups: 1. General adaptation (measures per side) and 2. Circumferential adaptation (average measure of the four faces). In both measurements there were no statistically significant differences, remaining both materials with statistically uniform marginal gap. CONCLUSIONS: both CAD / CAM systems tested showed similar and satisfactory results within the acceptable clinical standards and there was no sintering contraction difference between the disk (ronde) and block.
75

Análise da adaptação marginal de barras Ni-Cr tipo protocolo de Branemark pelo microscópio óptico e pelo microscópico confocal a laser / Marginal adaptation analysis of Ni-Cr bars Branemark protocol type from optical microscope and laser Confocal microscope

Jaccoud, Régis Eduardo Oliveira 28 September 2016 (has links)
A ausência de adaptação passiva em prótese sobre implantes pode sobrecarregar implantes, componentes protéticos e tecido ósseo, levando à perda óssea marginal e até da osseointegração. A soldagem é utilizada com frequência para melhorar o assentamento de estruturas metálicas de próteses em geral e de próteses sobre implantes. Além disso, a precisão no assentamento da peça protética pode estar relacionada com os cuidados na técnica de confecção da mesma. Assim, o objetivo deste trabalho foi avaliar, por meio de microscopia óptica e confocal a laser, a adaptação marginal de barras metálicas tipo protocolo de Branemark, de ligas de niquel-cromo (NiCr) em monobloco e soldadas, confeccionadas a partir de enceramento convencional. Para isso, foi confeccionado um modelo mestre, simulando quatro implantes sobre o qual foram adaptados transferentes e análogos que serviram para transferir a posição dos implantes para o modelo de gesso. Os enceramentos obtidos pelo método convencional foram fundidos em monobloco e em partes separadas (seccionados), sendo os últimos, posteriormente soldados utilizando as técnicas convencional a maçarico e TIG (Tungsten Inert Gas). As leituras da adaptação da barra em cada implante foram feitas nas peças em monobloco (n=5) e nas peças seccionadas (n=10), antes e após as diferentes técnicas de soldagem. Pelo método de medição de microscopia óptica, foram realizadas as medições em duas regiões pré-determinadas ( Vestibular e Lingual ), com três repetições, totalizando 6 leituras por implante. Já no método de microscopia Confocal a laser, foi realizada somente na Vestibular. Para comparar os dados obtidos quanto ao desajuste marginal entre componente protético/implante, considerando-se as peças em monobloco, as peças soldadas, as técnicas de soldagem (maçarico e TIG), os métodos de medição e a posição dos implantes, foram realizados testes estatísticos, onde para cada uma das análises realizadas foi determinada a aplicação do Teste de Normalidade (Shapiro-Wilk ou Kolmogorov-Smirnov (alfa = 5%)) para determinação da distribuição da amostra. Para a amostra com distribuição normal foi determinada a utilização do teste paramétrico, Análise de Variância, enquanto que a amostra com distribuição não normal, determinou-se a utilização do teste não paramétrico de Kruskal Wallis. Os resultados encontrados foram estatisticamente significantes para comparação método e técnica, sugerindo que as peças em monobloco apresentaram maior desadaptação que as peças soldadas, e que as peças soldadas pela técnica convencional não apresentaram diferença estatística, em relação as soldadas pela técnica TIG. Em relação a comparação dos métodos de medição, houve diferença estaticamente significante, onde a microscopia Confocal a laser obteve os maiores valores de desadaptação. A interação técnica e método não houve diferenças estatísticas. Na comparação de diferentes secções e soldada, para os 2 métodos de medição, em relação ao fator Secção, não houve diferença significante onde 3 secções apresentam os menores resultados e as soldadas tiveram igualdade em relação a 1 secção. Pelo fator Técnica houve diferença estatisticamente significante, onde a técnica convencional obteve as maiores médias. A interação Secção e Técnica, não teve efeito significante. A adaptação marginal da peça em relação a posição do implante na arcada, não houve diferença estatística, para ambos os métodos. Houve diferença apenas no fator Técnica, pela microscopia óptica, onde a Monobloco teve os maiores resultados e a Solda Convencional e TIG, tiveram igualdade nos resultados. A investigação de sistemas de confecção de estruturas da prótese e de técnicas de soldagem é importante na busca pela produção de próteses sobre dente ou sobre implante com precisão no ajuste marginal que possa ser comprovado visual e numericamente utilizando-se recursos tecnológicos que assegurem a utilização clínica das peças protéticas. / The lack of passive adaptation in prosthesis over implant can overload implants, prosthetics components and bone tissue, leading to marginal bone loss and even osseointegration. Weldering is used frequently to improve the settlement of metal structures of prosthetic in general and prosthesis over implants. In addition, the settlement precision of the workpiece may be related to the care in the technique of manufacturing the same. The objective of this study was to evaluate, through optical and confocal Laser microscopy, the marginal adaptation of metal bars Branemark protocol type alloy nickel-chromium (NiCr) monoblock and welded, made from conventional waxing .For this, a master model was made to simulate four implants were adapted over which transferents and analogs that served to transfer the position of the implants for the cast model. Waxing obtained by the conventional method were cast in one-piece and separate parts (sectioned), the latter being subsequently welded using the conventional techniques blowtorch and TIG (Tungsten Inert Gas).The bar adjustment of readings in each implant were made in monoblock pieces (n = 5) and the severed pieces (n = 10) before and after different weldering techniques. By optical microscopy measurement method, measurements were performed in two predetermined regions (Vestibular and lingual), with three replications, totaling 6 readings per implant. However in the methodology of Confocal laser microscope, was done only on Vestibular. To compare the data obtained on the misfit between prosthetic/implant component, considering the pieces monoblock, the welded parts, the weldering techniques (torch and TIG), measurement methods and the position of the implants, tests were performed statistical where for each of the analyzes determined the application of Normality Test (Shapiro-Wilk test and Kolmogorov-Smirnov test (alpha = 5%)) to determine the distribution of the sample. For the sample of normal distribution was determined using the parametric test, analysis of variance, while the sample with non-normal distribution was determined using the nonparametric Kruskal-Wallis test. The results found were statistically significant for method and technique comparison, suggesting that the monoblock parts showed higher misfit than welded parts, and the parts welded by conventional technique showed no statistical difference in relation welded by TIG technique. Regarding the comparison of measurement methods, there was no statistically significant difference, where the Laser Confocal microscopy obtained the greatest misfit. The technical interaction and method there were no statistical differences. When comparing different sections and welded to the two measurement methods, in relation to Section factor, there was no significant difference where 3 sections have the lowest results and welded had equality with 1 section. The technical factor was no statistically significant difference, the conventional technique had the highest averages. The interaction and Technical Section had no significant effect. The marginal adaptation of the play in relation to the implant in the arch position, there was no statistical difference for both methods. There was a difference only in the technical factor, by optical microscopy, where Monoblock had the greatest results and Conventional Welding and TIG, had equality in results. The research of making the prosthesis structures systems and weldering techniques is important in the search for production of prosthetic tooth or on precisely implant the marginal adjustment that can be verified visually and numerically using technological resources to ensure clinical use of prosthetic pieces.
76

Análise da adaptação marginal de barras Ni-Cr tipo protocolo de Branemark pelo microscópio óptico e pelo microscópico confocal a laser / Marginal adaptation analysis of Ni-Cr bars Branemark protocol type from optical microscope and laser Confocal microscope

Régis Eduardo Oliveira Jaccoud 28 September 2016 (has links)
A ausência de adaptação passiva em prótese sobre implantes pode sobrecarregar implantes, componentes protéticos e tecido ósseo, levando à perda óssea marginal e até da osseointegração. A soldagem é utilizada com frequência para melhorar o assentamento de estruturas metálicas de próteses em geral e de próteses sobre implantes. Além disso, a precisão no assentamento da peça protética pode estar relacionada com os cuidados na técnica de confecção da mesma. Assim, o objetivo deste trabalho foi avaliar, por meio de microscopia óptica e confocal a laser, a adaptação marginal de barras metálicas tipo protocolo de Branemark, de ligas de niquel-cromo (NiCr) em monobloco e soldadas, confeccionadas a partir de enceramento convencional. Para isso, foi confeccionado um modelo mestre, simulando quatro implantes sobre o qual foram adaptados transferentes e análogos que serviram para transferir a posição dos implantes para o modelo de gesso. Os enceramentos obtidos pelo método convencional foram fundidos em monobloco e em partes separadas (seccionados), sendo os últimos, posteriormente soldados utilizando as técnicas convencional a maçarico e TIG (Tungsten Inert Gas). As leituras da adaptação da barra em cada implante foram feitas nas peças em monobloco (n=5) e nas peças seccionadas (n=10), antes e após as diferentes técnicas de soldagem. Pelo método de medição de microscopia óptica, foram realizadas as medições em duas regiões pré-determinadas ( Vestibular e Lingual ), com três repetições, totalizando 6 leituras por implante. Já no método de microscopia Confocal a laser, foi realizada somente na Vestibular. Para comparar os dados obtidos quanto ao desajuste marginal entre componente protético/implante, considerando-se as peças em monobloco, as peças soldadas, as técnicas de soldagem (maçarico e TIG), os métodos de medição e a posição dos implantes, foram realizados testes estatísticos, onde para cada uma das análises realizadas foi determinada a aplicação do Teste de Normalidade (Shapiro-Wilk ou Kolmogorov-Smirnov (alfa = 5%)) para determinação da distribuição da amostra. Para a amostra com distribuição normal foi determinada a utilização do teste paramétrico, Análise de Variância, enquanto que a amostra com distribuição não normal, determinou-se a utilização do teste não paramétrico de Kruskal Wallis. Os resultados encontrados foram estatisticamente significantes para comparação método e técnica, sugerindo que as peças em monobloco apresentaram maior desadaptação que as peças soldadas, e que as peças soldadas pela técnica convencional não apresentaram diferença estatística, em relação as soldadas pela técnica TIG. Em relação a comparação dos métodos de medição, houve diferença estaticamente significante, onde a microscopia Confocal a laser obteve os maiores valores de desadaptação. A interação técnica e método não houve diferenças estatísticas. Na comparação de diferentes secções e soldada, para os 2 métodos de medição, em relação ao fator Secção, não houve diferença significante onde 3 secções apresentam os menores resultados e as soldadas tiveram igualdade em relação a 1 secção. Pelo fator Técnica houve diferença estatisticamente significante, onde a técnica convencional obteve as maiores médias. A interação Secção e Técnica, não teve efeito significante. A adaptação marginal da peça em relação a posição do implante na arcada, não houve diferença estatística, para ambos os métodos. Houve diferença apenas no fator Técnica, pela microscopia óptica, onde a Monobloco teve os maiores resultados e a Solda Convencional e TIG, tiveram igualdade nos resultados. A investigação de sistemas de confecção de estruturas da prótese e de técnicas de soldagem é importante na busca pela produção de próteses sobre dente ou sobre implante com precisão no ajuste marginal que possa ser comprovado visual e numericamente utilizando-se recursos tecnológicos que assegurem a utilização clínica das peças protéticas. / The lack of passive adaptation in prosthesis over implant can overload implants, prosthetics components and bone tissue, leading to marginal bone loss and even osseointegration. Weldering is used frequently to improve the settlement of metal structures of prosthetic in general and prosthesis over implants. In addition, the settlement precision of the workpiece may be related to the care in the technique of manufacturing the same. The objective of this study was to evaluate, through optical and confocal Laser microscopy, the marginal adaptation of metal bars Branemark protocol type alloy nickel-chromium (NiCr) monoblock and welded, made from conventional waxing .For this, a master model was made to simulate four implants were adapted over which transferents and analogs that served to transfer the position of the implants for the cast model. Waxing obtained by the conventional method were cast in one-piece and separate parts (sectioned), the latter being subsequently welded using the conventional techniques blowtorch and TIG (Tungsten Inert Gas).The bar adjustment of readings in each implant were made in monoblock pieces (n = 5) and the severed pieces (n = 10) before and after different weldering techniques. By optical microscopy measurement method, measurements were performed in two predetermined regions (Vestibular and lingual), with three replications, totaling 6 readings per implant. However in the methodology of Confocal laser microscope, was done only on Vestibular. To compare the data obtained on the misfit between prosthetic/implant component, considering the pieces monoblock, the welded parts, the weldering techniques (torch and TIG), measurement methods and the position of the implants, tests were performed statistical where for each of the analyzes determined the application of Normality Test (Shapiro-Wilk test and Kolmogorov-Smirnov test (alpha = 5%)) to determine the distribution of the sample. For the sample of normal distribution was determined using the parametric test, analysis of variance, while the sample with non-normal distribution was determined using the nonparametric Kruskal-Wallis test. The results found were statistically significant for method and technique comparison, suggesting that the monoblock parts showed higher misfit than welded parts, and the parts welded by conventional technique showed no statistical difference in relation welded by TIG technique. Regarding the comparison of measurement methods, there was no statistically significant difference, where the Laser Confocal microscopy obtained the greatest misfit. The technical interaction and method there were no statistical differences. When comparing different sections and welded to the two measurement methods, in relation to Section factor, there was no significant difference where 3 sections have the lowest results and welded had equality with 1 section. The technical factor was no statistically significant difference, the conventional technique had the highest averages. The interaction and Technical Section had no significant effect. The marginal adaptation of the play in relation to the implant in the arch position, there was no statistical difference for both methods. There was a difference only in the technical factor, by optical microscopy, where Monoblock had the greatest results and Conventional Welding and TIG, had equality in results. The research of making the prosthesis structures systems and weldering techniques is important in the search for production of prosthetic tooth or on precisely implant the marginal adjustment that can be verified visually and numerically using technological resources to ensure clinical use of prosthetic pieces.
77

Influ?ncia da t?cnica de fabrica??o e dos materiais sobre o ajuste da interface pilar/implante em infraestruturas implantossuportadas

Franca, Danilo Gonzaga Bernardo de 22 March 2013 (has links)
Made available in DSpace on 2014-12-17T15:43:52Z (GMT). No. of bitstreams: 1 DaniloGBF_DISSERT.pdf: 1485726 bytes, checksum: 4640fbe2db551567fc003e0585ff8950 (MD5) Previous issue date: 2013-03-22 / The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Br?nemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ? 3.6, 107.2 ? 36), CoCrcad (1.2 ? 2.2, 107.5 ? 26 ), CoCrUCci (11.8 ? 9.8, 124.7 ? 74), CoCrUCc (12.9 ? 11.0, 108.8 ? 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology / O objetivo deste estudo foi comparar o desajuste vertical, horizontal e a passividade de infraestruturas fabricadas em zirc?nia e cobalto-cromo por tecnologia CAD/CAM e pelo m?todo da fundi??o convencional. Dezesseis infraestruturas em monobloco, foram obtidas a partir de uma matriz met?lica contendo tr?s implantes Br?nemark compat?veis de plataforma regular (Titamax Cortical Ti, Neodent). Oito infraestruturas foram confeccionadas pelo sistema CAD/CAM (NeoShape, Neodent): quatro em zirc?nia (Zircad) e quatro em cobalto-cromo (CoCrcad). Outras oito infraestruturas foram obtidas pelo m?todo da fundi??o convencional: quatro em cobalto-cromo com pilar UCLA cinta Co-Cr (CoCrUCci) e quatro em cobalto-cromo com pilar UCLA calcin?vel (CoCrUCc). O ajuste vertical, horizontal e a passividade pelo teste do parafuso ?nico foram mensurados usando microscopia eletr?nica de varredura com aumento de 250x. Inicialmente avaliou-se a passividade pelo teste do parafuso ?nico e posteriormente para avaliar o desajuste vertical e horizontal, apertou-se todos os parafusos, com torque de 20Ncm. M?dia, desvio padr?o, valor m?nimo e m?ximo foram calculados para cada grupo. As medidas de desajuste horizontal foram transformadas em frequ?ncia cumulativa para categoriza??o da vari?vel e posterior compara??o grupos a grupo. Para avaliar a exist?ncia de diferen?as quantitativas entre os grupos testados para desajuste vertical e passividade, foi usado o teste Kruskal-Wallis. O teste Mann-Whitney foi usado para comparar as diferen?as estat?sticas grupo a grupo (p<0,05). Foram observados os respectivos valores de m?dia e desvio padr?o em micr?metros para desajuste vertical e passividade: Zircad (5,9 ? 3,6; 107,2? 36), CoCrcad (1,2 ? 2,2; 107,5? 26), CoCrUCci (11,8 ? 9,8; 124,7? 74), CoCrUCc (12,9 ? 11,0; 108,8? 85). Observaram-se diferen?as estat?sticas para medidas de desajuste vertical (p=0,000). O teste Mann-Whitney revelou diferen?as estat?sticas (p<0,05) entre todos os grupos, exceto entre CoCrUCci e CoCrUCc (p=0,619). Nenhuma diferen?a estat?stica foi observada para a passividade das infraestruturas. Em rela??o ao desajuste horizontal, os grupos ZirCAD e CoCrcad n?o apresentaram melhores valores em rela??o a CoCrUCci e CoCrUCc. Baseado nos resultados pode-se concluir que infraestruturas confeccionadas por tecnologia CAD/CAM obtiveram melhores valores de ajuste vertical que aquelas fabricadas pelo m?todo da fundi??o, apesar disso, a passividade das infraestruturas n?o foi influenciada pela t?cnica de fabrica??o e material utilizado. O ajuste horizontal obtido pelas infraestruturas fabricadas por CAD/CAM n?o foi superior ?quelas fabricadas por fundi??o. Uma menor variabilidade no ajuste vertical e na passividade foi observada quando infraestruturas foram fabricadas por tecnologia CAD/CAM
78

Avaliação da adaptação de estruturas em Y-TZP entre diferentes sistemas CAD/CAM / Adaptation assessment of Y-TZP frameworks between different CAD / CAM systems

Andreas Raphael Ribas Koren 04 March 2013 (has links)
OBJETIVOS: comparar dois sistemas CAD-CAM de diferentes gerações quanto ao grau de adaptação de infraestruturas estéticas de próteses fixas de três elementos para verificar se existe alguma evolução no quesito diminuição do gap marginal e se existe diferença de contração entre blocos de conformações diferentes que podem afetar diretamente a adaptação das mesmas. MATERIAL E MÉTODOS: para isso foi confeccionado um preparo de prótese fixa de três elementos em manequim odontológico simulando a ausência do elemento dental 25; posteriormente aos preparos foi reproduzido um modelo mestre em liga metálica Co-Cr para serem realizados os testes. O modelo mestre foi submetido a escaneamento em cada sistema comercial para a infraestrutura ser desenhada e fresada. Para serem confrontados, em cada sistema CAD/CAM foi confeccionado cinco infraestruturas em Y-TZP (n=5), sendo que no grupo CT1 foi utilizado um disco (ronde) com dimensões de 98x20 mm capaz de ser fresada até seis infraestruturas de uma só vez enquanto que no grupo CT2 cada infraestrutura foi confeccionada individualmente em um bloco com dimensões de 40x15x19 mm. Uma vez concluídas as infraestruturas, as mesmas foram submetidas a teste de adaptação com a técnica do dedal de silicone e posteriormente em cada preparo, tanto do molar quanto do pré-molar, foi retirada uma fatia de 2 mm de espessura em cada face (mesial, distal, lingual e vestibular) para se analisar a espessura de desadaptação na região de término através da análise de imagem (fotografia das fatias realizado por estereomicroscópio e medição com o software ImageJ). Os resultados foram submetidos aos testes de Normalidade e Homocedasticidade (p=0,05) e posteriormente analisados por ANOVA e Tukey (p=0,05). RESULTADOS: as medições foram divididas em dois grupos: 1. Adaptação geral ( medidas por face) e 2. Adaptação circunferencial (média das medidas das quatro faces). Em ambas as medições não houve diferenças estatisticamente significantes, permanecendo o gap marginal de ambos os materiais com resultados estatisticamente uniformes. CONCLUSÕES: ambos os sistemas CAD/CAM testados apresentaram resultados semelhantes e satisfatórios, dentro dos padrões clínicos aceitáveis e não houve diferença de contração de sinterização entre o disco (ronde) e o bloco. / OBJECTIVES: compare two CAD-CAM systems of different generations according to the adaptation level of three elements aesthetic FPD to discover if there are any changes in the item \"gap marginal decrease\" and if there is contraction differences between blocks of different conformations that may directly affect the adaptation. MATERIAL AND METHODS: it was made a FPD preparation (total crown preparation in each pillar tooth) in a dental mannequin, simulating the absence of the tooth 25; later was made a master template in Co-Cr alloy to be performed the tests, according to the mannequin preparations. The master model was subjected to scanning in each trading system to be designed the infrastructure and posteriorly milled. It was made five infrastructure in Y-TZP (n = 5) to be compared in every CAD / CAM system, and in the CT1 group was used a disc (ronde) with dimensions of 98x20 millimeters, where it can be milled up to six infrastructure of a once, while in the group CT2 each structure was fabricated into a single block with dimensions of 40x15x19 millimeters. After the infrastructure was milled, they were subjected to the adaptive technique of \"silicone replica\" and subsequently in each preparation (molar and premolar) was withdrawn from a 2 mm thickness slice on each side (mesial, distal, lingual and buccal) to analyze the mismatch thickness in the end region via image analysis (slices photography performed by a stereomicroscope and measured by the ImageJ software). The results were submited by Normality and Homoscedasticity test (p=0.05) and subsequently analyzed by ANOVA and Tukey test (p=0.05). RESULTS: the measurements were divided into two groups: 1. General adaptation (measures per side) and 2. Circumferential adaptation (average measure of the four faces). In both measurements there were no statistically significant differences, remaining both materials with statistically uniform marginal gap. CONCLUSIONS: both CAD / CAM systems tested showed similar and satisfactory results within the acceptable clinical standards and there was no sintering contraction difference between the disk (ronde) and block.
79

Influência de técnicas de moldagem com e sem casquetes na exatidão dimensional de modelos de gesso e adaptação marginal de infraestruturas em zircônia / Influence of impression techniques with and without acrylic copings on the dimensional accuracy of gypsum casts and marginal fit of zirconia frameworks

Silva, Stephania Caroline Rodolfo [UNESP] 20 June 2016 (has links)
Submitted by Stephania Caroline Rodolfo Silva null (stephaniacrsilva@foar.unesp.br) on 2016-08-18T20:52:01Z No. of bitstreams: 1 Dissertação Defesa Stephania C. R. Silva 18.08.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-08-19T20:19:26Z (GMT) No. of bitstreams: 1 silva_scr_me_arafo.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5) / Made available in DSpace on 2016-08-19T20:19:26Z (GMT). No. of bitstreams: 1 silva_scr_me_arafo.pdf: 885533 bytes, checksum: cf1bd5bf272a148a2e397dbde32c3029 (MD5) Previous issue date: 2016-06-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente estudo analisou a exatidão de modelos de gesso, obtidos a partir de diferentes técnicas de moldagem, incluindo casquetes individuais, isolados ou unidos, bem como mensurou o desajuste marginal cervical de infraestruturas de zircônia sobre preparos dentais para coroa total. Foi utilizado um modelo mestre (controle), com preparos nos dentes 14, 16, 21 e 25, sobre o qual infraestruturas de zircônia foram confeccionadas por tecnologia CAD/CAM. Para cada técnica de moldagem: simultânea com silicone de condensação (T1a), ou adição (T1b); casquetes individuais isolados (T2); unidos com cilindros de resina acrílica (T3); unidos com cilindros metálicos (T4); foram obtidos 8 moldes totais, por único operador calibrado, com moldeira de estoque. As moldagens com casquetes foram realizadas com poliéter e as transferências com silicone de condensação. Para a análise da adaptação marginal cervical das infraestruturas de zircônia, as mesmas foram passivamente adaptadas sobre os preparos nos modelos de gesso, sendo as mensurações do desajuste marginal cervical realizadas em estereomicroscópio (50x). Para a análise de exatidão dimensional linear oclusal global, os modelos foram escaneados e, a partir de três pontos pré-definidos, realizadas mensurações látero-laterais (LL) e anteroposteriores (AP) bilaterais do arco dental no programa ImageJ. Além disso, mensurações das dimensões áxio-cervicais de cada preparo e da distância entre os preparos do segmento 14-16 foram realizadas com paquímetro digital. Métodos estatísticos (α=0,05) foram empregados para avaliar a influência das técnicas de moldagem. Para o desajuste cervical, não houve diferença (p>0,05) para o dente 21. Para os dentes 14 e 16, apenas a técnica com casquetes individuais isolados apresentou diferença (p<0,05) em relação ao controle; enquanto para o dente 25 todas as técnicas com casquetes diferiram (p<0,05) do controle. Na mensuração da exatidão dimensional global, nenhuma técnica apresentou diferença (p>0,05) em relação ao controle. Para as mensurações áxio-cervicais do dente 25, todas as técnicas com casquete foram diferentes (p<0,05) do controle. Não houve diferença (p>0,05) nas dimensões do dente 21 e da distância interpreparos do segmento 14-16. De maneira geral, a técnica com casquetes isolados produziu modelos com maior desajuste marginal cervical. A forma de união dos casquetes, não apresentou influência sobre a exatidão dos modelos. / This study examined the accuracy of gypsum casts obtained from different impression techniques, including individual acrylic copings, and measured the cervical misfit of zirconia frameworks on dental preparations for fixed prosthodontics. A master cast with preparations in the teeth #14, 16, 21 and 25, on which zirconia frameworks were made by CAD/CAM technology, was used as control (baseline measurements). For each impression technique: single-step with condensation silicone (T1a), or vinyl polysiloxane (T1b); individual acrylic copings (T2); acrylic copings bonded with acrylic resin cylinders (T3) or metal cylinders (T4), 8 impressions were obtained by a single calibrated operator using stock trays. For the techniques T2, T3 and T4, polyether was used into the acrylic copings and condensation silicone was used for their pick-up. For the analysis of cervical marginal fit, zirconia frameworks were passively seated on the dental preparations of the gypsum casts, and measurements of cervical misfit calculated in stereo (50x). For the analysis of occlusal linear dimensional accuracy, the casts were scanned and, from three pre-defined points, side-to-side (LL) and bilateral anteroposterior (AP) measurements were performed by means of digitized images in the ImageJ software. Additionally, measurements of axio-cervical dimensions of each dental preparation and the distance between the preparations of the #14-16 fixed prosthodontics’ segment were taken with a digital caliper. Statistical analyzes (α=.05) were used to evaluate the influence of impression techniques. For cervical misfit, there was no difference (p>.05) for the tooth #21. For the teeth #14 and 16, only the technique T2 showed significant difference (p<.05) comparing to control; while for the tooth #25 all techniques with acrylic copings (T2, T3 and T4) differ (p<.05) from control. No significant differences were found among the techniques and the control (master cast) for the occlusal linear dimensions (p>.05). For axio-cervical measurements of tooth #25, all techniques using acrylic copings differ (p<.05) from control. There was no difference (p>.05) in the axio-cervical dimensions of tooth #21 and interpreparation distance of the #14-16 segment. In general, the technique with isolated acrylic copings (T2) produced casts with larger cervical misfit. The method for bonding the acrylic copings, by acrylic or metal cylinders, had no effect on the accuracy of the casts.
80

Comparación in vitro de la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado / In vitro comparison of the marginal adaptation of ceramic glass porcelain crowns manufactured with three processing systems

Zegarra Cavero-Blumenfeld, Fernanda, Meza Huamán, Katya Valeria 02 December 2020 (has links)
Objetivo: Comparar in vitro la adaptación marginal de coronas unitarias de porcelana vitrocerámica elaboradas con tres sistemas de procesado. Materiales y métodos: El presente estudio fue de tipo experimental in vitro. La muestra estuvo conformada por 69 coronas de porcelana vitrocerámica fabricadas con los sistemas: CAD-CAM, inyección de porcelana y condensación sobre muñón refractario. Para la evaluación de la discrepancia marginal vertical se realizó un registro fotográfico con una cámara digital y un lente macroscópico de 100 milímetros. Las imágenes fueron medidas digitalmente (ImageJ) y se utilizaron 52 puntos aleatorios de discrepancia marginal vertical alrededor de las coronas para obtener el promedio de cada una de ellas. Se utilizó la prueba de Kruskal-Wallis para realizar la comparación entre los grupos de estudio con un nivel de significancia estadística de p<0.05. Resultados: El presente estudio encontró diferencias estadísticamente significativas al comparar los tres sistemas de procesado (<0.001). El sistema CAD-CAM tuvo una discrepancia marginal vertical menor (53 µm) en comparación con el sistema de inyección de porcelana (85 µm) y el de condensación sobre muñón refractario (113 µm). Conclusiones: Se encontraron diferencias estadísticamente significativas entre los tres grupos de estudio. Asimismo, el sistema CAD-CAM tuvo una mayor adaptación marginal en comparación con los otros dos métodos de fabricación. Finalmente, los tres sistemas de confección utilizados tuvieron una discrepancia marginal vertical por debajo del límite establecido por la Asociación Americana de Odontología (<120 µm). / Objective: To compare in vitro the marginal adaptation of ceramic glass porcelain single crowns made with three processing systems. Materials and methods: The present study was experimental in vitro. The sample consisted of 69 glass ceramic porcelain crowns manufactured with the following three systems: CAD-CAM, porcelain injection and powder condensation. For de measurement of the vertical marginal discrepancy, the crowns were photographed using a digital camera with a macroscopic lens of 100 millimeters. The images were imported into image processing software (ImageJ) and 52 points were randomly selected around the crown to measure the vertical marginal discrepancy. For each crown, the 52 measurements were combined into a single average marginal discrepancy. Kruskal-Wallis was used to test differences in the observed marginal discrepancies between the study groups. (p <0.05) Results: This study found statistically significant differences when comparing the three different processing systems (<0.001). The CAD-CAM system had a smaller vertical marginal discrepancy (53 µm) compared to the porcelain injection (85 µm) and the powder condensation techniques (113 µm). Conclusions: Statistically significant differences were found between the three study groups. Also, the CAD-CAM system had a greater marginal adaptation compared to the other two manufacturing techniques. Finally, the three fabrication methods used in this study had a vertical marginal discrepancy within the limit established by the American Dental Association (<120 µm). / Tesis

Page generated in 0.1414 seconds