• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 311
  • 40
  • 40
  • 39
  • 39
  • 24
  • 16
  • 6
  • 6
  • 6
  • 2
  • 1
  • 1
  • Tagged with
  • 314
  • 314
  • 99
  • 73
  • 56
  • 46
  • 40
  • 39
  • 35
  • 35
  • 34
  • 34
  • 33
  • 32
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Desenvolvimento e caracterização de novas ligas do sistema Ti-Ta-Zr para aplicações biomédicas /

Kuroda, Pedro Akira Bazaglia. January 2019 (has links)
Orientador: Carlos Roberto Grandini / Resumo: Titânio e suas ligas, atualmente, são utilizados como implantes por possuírem excelente resistência à corrosão e propriedades mecânicas mais adequadas que os implantes de aço inoxidável e de Co-Cr. A liga de titânio mais utilizada para aplicações biomédicas é a liga Ti-6Al-4V, porém estudos mostraram que os elementos vanádio e alumínio são elementos nocivos à saúde humana. Assim, para contornar este problema, novas ligas de titânio sem a presença desses elementos estão sendo estudadas. O objetivo desse trabalho foi preparar ligas do sistema Ti-25Ta-Zr (onde o teor de zircônio foi variado de 0 a 75% em peso), e analisar a influência do soluto substitucional zircônio na estrutura cristalina, microestrutura, microdureza, módulo de elasticidade e biocompatibilidade das ligas. Paralelamente, diversos tratamentos de recozimento, laminação e solubilização foram realizados com o intuito de modificar as fases, microestrutura e módulo de elasticidade dos materiais. A caracterização química dos materiais foi realizada por espectroscopia de energia dispersiva, espectrometria de emissão óptica por plasma acoplado indutivamente, análise de gases e medidas de densidade. A análise estrutural foi efetuada por difração de raios X. A análise microestrutural foi realizada por microscopia ótica, microscopia eletrônica de varredura e de transmissão. Uma análise preliminar das propriedades mecânicas da liga foi obtida por intermédio de medidas de microdureza Vickers e módulo de elasticidade dinâmic... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and alloys currently are used as implants possessing excellent corrosion resistance and mechanical properties more suited to stainless steel implants and Co-Cr. The titanium alloy used for most biomedical applications is Ti-6Al-4V, however studies showed that vanadium and aluminum are harmful to human health. The objective of this study was to prepare Ti-25Ta-Zr system alloys, where the zirconium content was varied from 0 to 75 % in weight, and to analyze the influence of zirconium substitutional solute in the structure, microstructure, hardness and elastic modulus. At the same time, several annealing, lamination and solubilization treatments were carried out to modify the phases, structures, microstructure and elastic modulus of the materials. The chemical characterization of materials was performed by energy-dispersion spectroscopy, inductively coupled plasma optical emission spectrometry, gas analysis, and density measurements. The structural analysis was performed by x-ray diffraction measurements. Microstructural analysis was performed by optical, scanning and transmission electron microscopy. To verify the initial biocompatibility of the alloys, cytotoxic tests were performed. A preliminary analysis of the mechanical properties of the alloy was obtained by means of microhardness and dynamic elastic modulus measurements. The chemical composition results showed that the samples produced are of good quality, close to proposed stoichiometry. The results showed the ... (Complete abstract click electronic access below) / Doutor
72

Deposição por sputtering de filmes finos resistentes à tribocorrosão, sobre titânio, visando aplicações biológicas. /

Corrêa, Patrícia January 2020 (has links)
Orientador: Luís Augusto Sousa Marques da Rocha / Resumo: O titânio (Ti) é um material que apresenta boa resistência à fadiga e à corrosão. Ainda que seja utilizado na fabricação de próteses ortopédicas e implantes dentários, o titânio metálico não é bioativo, ou seja, não é capaz de provocar reações que favoreçam a fixação de implantes, biocolonização ou a regeneração de tecidos, além de apresentar alguns inconvenientes relacionados a propriedades de superfície, que podem levar à sua degradação. Para fins biomédicos, essa degradação se dá principalmente por processos de tribocorrosão, que ocorre quando ações mecânicas e químicas acontecem de formas concomitantes. Diante deste cenário, superfícies de titânio (Ti) foram recobertas com filmes finos de óxido de titânio (TiO2) por meio da técnica de Sputtering reativo. O principal objetivo do trabalho foi entender como as fases anatase e rutilo dos filmes de TiO2, produzidos por sputtering reativo, podem influenciar na resistência dessas superfícies de titânio, recobertas, à tribocorrosão. São apresentadas análises estruturais e de composição desses filmes, a partir de difração de raios-X e espectroscopia Raman, que confirmam a obtenção de filmes finos compostos de diferentes proporções entre as fases anatase e rutilo, além de uma análise detalhada da forma de crescimento, a partir de microscopia eletrônica de transmissão (MET). O trabalho apresenta uma análise da resistência dos filmes finos de TiO2 no que diz respeito aos mecanismos de tribocorrosão, em meios fisiológicos. Nesse senti... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium (Ti) is a material that has good resistance to fatigue and corrosion. Although it is used in the manufacture of orthopedic prostheses and dental implants, metallic titanium is not bioactive, that is, it is not capable of causing reactions that favor the fixation of implants, biocolonization or tissue regeneration, in addition to presenting some inconveniences related to surface properties, which can lead to its degradation. For biomedical purposes, this degradation occurs mainly through tribocorrosion processes, which occur when mechanical and chemical actions occur in concomitant ways. In view of this scenario, titanium (Ti) surfaces were covered with thin films of titanium oxide (TiO2) using the reactive Sputtering technique. The main objective ofthe work was to understand how the different phases present in TiO2films, anatase and rutile, can influence the resistance of these surfaces relatedto tribocorrosion.Structural and composition analyzes of these films are presented, using X-ray diffraction and Raman spectroscopy, which confirm the achievement of thin films composed of different proportions between the anatase and rutile phases. Inaddition, a detailed analysis of the growth morphology was performed using transmission electron microscopy (TEM). The work presents an analysis of the resistance of TiO2thin films with respect to tribocorrosion mechanisms, in physiological media. In this sense, the tribocorrosion tests were carried out, the electrochemical data ar... (Complete abstract click electronic access below) / Doutor
73

Utilização da fibrina rica em plaquetas e leucócitos (L-PRF) em procedimentos cirúrgicos de elevação do assoalho do seio maxilar /

Malzoni, Carolina Mendonça de Almeida. January 2020 (has links)
Orientador: Daniela Leal Zandim-Barcelos / Resumo: A fibrina rica em plaquetas e leucócitos (L-PRF) é um derivado plaquetário autógeno capaz de liberar citocinas e fatores de crescimento favoráveis ao reparo tecidual. Por esta razão a L-PRF vem sendo utilizada em diversos procedimentos odontológicos. Uma das aplicabilidades clínicas da L-PRF é em procedimentos de levantamento do seio maxilar, uma técnica já consagrada na odontologia que permite a colocação de implantes dentários em região posterior de maxilas atróficas. Para avaliar a efetividade do uso da L-PRF, dois estudos clínicos independentes foram realizados utilizando a L-PRF em seios maxilares. Um deles teve o propósito de avaliar a influência da L-PRF na regeneração óssea quando associada ao osso mineral bovino desproteinizado (OBD) em procedimentos de elevação do assoalho do seio maxilar, e o outro teve o propósito de avaliar a efetividade da L-PRF no reparo de membranas de Schneider acidentalmente perfuradas durante o procedimento de levantamento do seio maxilar. Para isso, o primeiro trabalho foi um estudo clínico randomizado controlado envolvendo 19 pacientes com edentulismo na região posterior de maxila. De forma aleatória, 24 seios maxilares destes 19 pacientes foram distribuídos entre os grupos teste e controle. O grupo teste abordou 12 seios maxilares que foram enxertados com OBD associado à L-PRF, já o grupo controle abordou outros 12 seios maxilares enxertados apenas com OBD. Após 8 meses de reparo, uma biópsia foi obtida por meio de broca trefina no mesmo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Platelet and leukocyte-rich fibrin (L-PRF) is an autogenous platelet derivative capable of releasing cytokines and growth factors favorable to tissue repair. For this reason, LPRF has been used in several dental procedures. One of the clinical applicabilities of L-PRF is in maxillary sinus lifting procedures, a technique already established in dentistry that allows the placement of dental implants in the posterior region of atrophic jaws. To assess the effectiveness of using L-PRF, two independent clinical studies were conducted using L-PRF in maxillary sinuses. One of them had the purpose of evaluating the influence of L-PRF in bone regeneration when associated with deproteinized bovine mineral bone (DBB) in maxillary sinus floor elevation procedures, and the other had the purpose of evaluating the effectiveness of L-PRF in the repair of Schneider membranes accidentally perforated during the maxillary sinus lifting procedure. For this, the first study was a randomized controlled clinical study involving 19 patients with edentulism in the posterior region of the maxilla. At random, 24 maxillary sinuses of these 19 patients were distributed between the test and control groups. The test group involved 12 maxillary sinuses that were grafted with DBB associated with L-PRF, whereas the control group addressed 12 other maxillary sinuses grafted only with DBB. After 8 months of repair, a biopsy was obtained using a drill bit on the same axis of insertion of the implants. The biopsie... (Complete abstract click electronic access below) / Mestre
74

Variações morfológicas e estruturais nos filmes de TiO2 formados pela anodização de titânio /

Palma, Dener Pedro da Silva January 2019 (has links)
Orientador: Heloisa Andréa Acciari / Resumo: Nas últimas décadas houve um enorme crescimento do uso titânio comercialmente puro nos mais variados setores da economia como por exemplo na indústria petrolífera, aeroespacial e biomédica. Na indústria biomédica o uso desse metal se caracteriza por ter propriedades mecânicas semelhantes às do osso do corpo humano, por apresentar excelente resistência à corrosão quando comparado com outros metais, e também por ser biocompatível. A biocompatibilidade do titânio ocorre em função da camada de óxido que é formada sobre a superfície deste metal quando exposto a uma atmosfera em que há a presença de oxigênio. Esta camada pode ser amorfa ou cristalina, geralmente quando formada espontaneamente os filmes são amorfos, porém para o uso biomédico é interessante que a fase cristalina anatase se forme sobre a superfície do titânio, pois de acordo com a literatura esta fase favorece a osseointegração. Sendo assim várias técnicas de modificação de superfície, como por exemplo, anodização, tratamento térmico, eletrodeposição, são estudadas para melhorar as propriedades da camada de TiO2. Por tanto, o objetivo desse trabalho foi investigar como os parâmetros de anodização e características de filmes anódicos estão relacionados. Os filmes foram obtidos por anodização em soluções de 0,25 e 2,5 mol L-1 de H3PO4 em três tempos de anodização (3, 6 e 12 horas), comparando dois tipos de substratos: superfícies de titânio eletropolidas e polidas com alumina, com a finalidade de obter uma superfície m... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In the last decades, there has been a great growth in the use of commercially pure titanium in the most varied sectors of the economy, such as in the aerospace and biomedical industries. In the biomedical industry the use of this metal is due to its properties, such as mechanical strength, which is similar to human bone, as well as its excellent corrosion resistance compared to other metals, and also because of it is a biocompatible element. The biocompatibility of titanium occurs as a function of the oxide layer formed on the surface of this metal when it is exposed to an atmosphere where there is the presence of oxygen. This layer can be amorphous or crystalline, usually when it is formed spontaneously the films are amorphous, but for biomedical use it is interesting that the morphology of the anodic film is composed by the Crystalline phase of the anatase, because according to the literature this phase favors osseointegration. In order to improve the properties of the titanium oxide layer, various surface modification techniques have been studied, such as anodizing, heat treatment and electrodeposition. Thus, the proposal of this work was to investigate how the anodization parameters and the characteristics of anodic films are related. The films were obtained by anodization in 0.25 and 2.5 mol L-1 H3PO4 solutions in three anodization times (3, 6 and 12 hours), comparing two types of substrates: electropolished and non-electropolished titanium surfaces, aimed to create a mo... (Complete abstract click electronic access below) / Mestre
75

Incorporação de óxido de ferro em superfície nanoporosa de TiO2 crescida sobre a liga Ti10Mo8Nb visando aplicação biomédica /

Domingues, Danielle Duque. January 2019 (has links)
Orientador: Miguel Angel Ramirez Gil / Resumo: O titânio e as suas ligas são utilizados em aplicações biomédicas devido às suas excelentes propriedades, tais como resistência mecânica e biocompatibilidade. As técnicas de modificação de superfície são utilizadas nestas ligas para alterar as propriedades de superfície, aumentar a osseointegração e evitar falhas em implantes. Além destas técnicas, a incorporação de nanopartículas na superfície do implante têm sido grande aliada dos biomateriais, em especial às do óxido de ferro, devido às suas propriedades físico-químicas, sua biocompatibilidade e biodegradabilidade. O objetivo dessa dissertação foi propor método de incorporação de óxido de ferro na superfície nanoporosa da liga experimental Ti10Mo8Nb modificada por oxidação anódica, visando aplicações biomédicas. Os lingotes da liga experimental Ti10Mo8Nb foram obtidos a partir da fusão dos metais puros em forno a arco voltaico. A anodização foi realizada para obtenção das nanoestruturas de TiO2 (tensão de 20 V por 3 h), resultando em diâmetro interno dos nanoporos igual a aproximadamente 24 nm. A síntese do óxido de ferro foi realizada usando o método dos precursores poliméricos, sendo avaliado o comportamento reológico (viscosidade de 22,65 mPa.s) e a temperatura de cristalização para formação de nanopartículas de óxido de ferro. A partir da difratometria de raios X e da microscopia eletrônica de varredura, a temperatura de calcinação mais adequada para a formação da fase pura de hematita foi 600°C. A incorporação do óxid... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium and its alloys are used in biomedical applications because of their excellent properties, such as mechanical resistance and biocompatibility. Surface modification techniques are used to alter the surface properties, increase osseointegration and avoid implant failure. Beside these techniques, nanoparticles incorporation on implant surface are great biomaterials allies, specially iron oxides, due to their physicochemical properties, biocompatibility and biodegradability. The objective of this dissertation was to propose a method of iron oxide incorporation on the surface of experimental alloy Ti10Mo8Nb modified by anodization. The ingots of experimental alloy Ti10Mo8Nb were obtained from melting pure metals in an arc furnace. Anodization process was performed to obtain the TiO2 nanostructures, with internal diameter 24 nm. Iron oxide synthesis was carried out using the method of the polymeric precursors, assessing rheological behavior (22,65 mPa.s viscosity) and crystallization temperature ideal to produce iron oxide nanoparticles. Results from X Ray Diffratogram and Scanning Electron Microscopy presented that the most adequated annealing temperature to pure phase hematite was 600°C. Iron oxide incorporation on alloy surface was performed by immersion and spin coating, and in the second method the deposition was uniform and widespread. Spin coating was performed with 3 and 5 layers of iron oxide deposition, implying that with 5 layers is most appropriate because it do... (Complete abstract click electronic access below) / Mestre
76

Tratamento biomimético de discos e implantes de titânio com alendronato : caracterização topográfica, estudo histométrico e imunoistoquímico em coelhos /

Figueira Júnior, Heldo Cesar. January 2018 (has links)
Orientador: Idelmo Rangel Garcia Junior / Coorientadora: Roberta Okamoto / Banca: Francisley Ávila Souza / Banca: Leonardo Perez Faverani / Banca: Vilmar Devanir Gottardo / Banca: André Luís da Silva Fabris / Resumo: Tratamentos de superfície de materiais implantáveis no corpo humano são analisados incansavelmente dentro das áreas da saúde. É comum ser observado em artigos científicos o emprego de um recente e desconhecido biomaterial sendo analisado para este fim. O objetivo deste estudo foi avaliar o emprego do alendronato sobre a caracterização topográfica de implantes e discos de titânio in vitro, e sobre a superfície de implantes de titânio inseridos em coelhos após levantamento de seio maxilar, correlacionando as respostas biológicas e físicas do tratamento comparadas a protocolos bem estabelecidos da implantodontia. Utilizou-se seis discos e vinte e seis implantes dentários ambos de titânio comercialmente puro. Para as análises topográficas, discos e implantes se dividiram em 2 grupos de 3 amostras: Grupo CTL, submetidos a subtração ácida e grupo ALD, submetidos a tratamento biomimético com alendronato. Para os testes em animais, 5 implantes foram distribuídos por grupo, CTL e ALD, com intervalos de eutanásia de 7 e 40 dias. Após microscopia eletrônica de varredura, análise de espectroscopia por energia dispersiva, análise do ângulo de contato com a água, de energia livre de superfície e da presença de sítios doares de elétrons (base de Lewis), os grupos ALD apresentaram resposta satisfatória frente aos processos aceitos em saúde, sendo superiores em todas as análises. A resposta histométrica também foi mensurada resultando em maior tecido ósseo nas análises ELCOI e AON nos grupos ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Surface treatments of implantable materials in the human body are analyzed tirelessly within the health areas. It is common to observe in scientific articles the use of a recent and unknown biomaterial being analyzed for this purpose. The objective of this study was to evaluate the use of alendronate on the t opographic c haracterization of implants and titanium discs in vitro, and over the surface of titanium implants inserted into rabbits after maxillary sinus lift, correlating the biological and physical responses of the treatment compared to well established implantology protocols. It was used six disks and twenty - six commercially pure titanium dental implants. For the topographic analyzes, disks and implants were divided into 2 groups of 3 samples: CTL group, submitted to acid subtraction and ALD group, submi tted to biomimetic treatment with alendronate. For the animal tests, 5 implants were distributed per group, CTL and ALD, with euthanasia intervals of 7 and 40 days. After scanning electron microscopy, analysis of energy dispersive spectroscopy, analysis of the water contact angle, free surface energy and the presence of electron ́s donor sites (Lewis base), the ALD groups showed a satisfactory response to the accepted processes in health, being superior in all the analyzes. The histometric response was also measured resulting in increased bone tissue in the ELCOI and AON analyzes in the ALD 40 days' group. The discrete presence of TRAP at 40 days refers to low bo... (Complete abstract click electronic access below) / Doutor
77

Nanocompósitos naturais de celulose bacteriana para medicina regenerativa /

Olyveira, Gabriel Molina de. January 2016 (has links)
Orientador: Antônio Carlos Guastaldi / Banca: Sandra Helena Pulcinelli / Banca: Luis Geraldo Vaz / Banca: Jorge Enrique Rodriguez Chanfrau / Banca: Gildásio de Cerqueira Daltro / Resumo: A engenharia de tecidos é um campo que aplica os princípios de engenharia e ciências biológicas para desenvolver substitutos biológicos que restauram, mantém ou melhoram o tecido ou a função do órgão por inteiro. A presente tese estudou arcabouços (scaffolds) produzidos com celulose bacteriana/fosfato de cálcio voltados para a regeneração óssea. Foram analisados a modificação do processo de fermentação da celulose bacteriana com moléculas naturais (sulfato de condroitina e ácido hilaurônico), modificações físicas superficiais empregando-se irradiação gamma na celulose bacteriana e método biomimético para formação de fosfato de cálcio na superfície da membrana, posteriormente foram testados os biomateriais com células do ovário de hamster chineses (CHO-K1 cells). A modificação com moléculas naturais alterou a carga superficial e a cristalinidade das membranas, a modificação física alterou também propriedades físico-químicas de superfície, interferindo no processo de deposição de fosfato de cálcio. Os fosfatos de cálcio testados pelo método biomimético (SBFs 1 e 3), tiveram resultados melhores quanto a sua incorporação na superfíce das membranas não irradiadas de celulose bacteriana e seus nanocompósitos. / Doutor
78

Interação de proteínas em superfícies de filmes finos de TiO2 e sua resposta biológica /

Gomes, Orisson Ponce. January 2019 (has links)
Orientador: Paulo Noronha Lisboa Filho / Banca: André Luis de Jesus Pereira / Banca: Willian Fernando Zambuzzi / Resumo: O dióxido de titânio (TiO2) nanoestruturado tem sido empregado como modificador de superfície em implantes médicos, promovendo melhoria na resistência à biocorrosão do material e aumento da bioatividade, apresentando resultados promissores na interação com o tecido vivo. Apesar da biocompatibilidade deste óxido ser reconhecida, ainda existem muitos aspectos dos mecanismos de adesão entre as proteínas e a superfície do material que não são totalmente compreendidos. Quimicamente, a superfície desses óxidos é principalmente terminada por grupos -OH que podem ser prontamente funcionalizados. Essa funcionalização química ou simplesmente uma alteração física da superfície do material, pode melhorar a interação do óxido com o ambiente biológico. Além disso, dióxido de titânio pode ter o número de grupos hidroxila aumentado por indução física sob exposição a luz ultravioleta. Embora os grupos gerados por esse processo sejam termodinamicamente menos estáveis, o número maior de sítios ativos disponíveis para serem ligados às moléculas orgânicas pode resultar em uma funcionalização mais eficiente. Nesse trabalho são apresentados os estudos conformacionais de adsorção de três moléculas bifuncionais diferentes, ácido 3-mercaptopropiônico (MPA), 3-aminopropiltrimetoxisilano (APTMS) e ácido 3-(4-aminofenil)propiônico (APPA), que atuam como espaçadoras no processo de imobilização de proteína nas superfícies fisicamente hidroxiladas dos filmes de TiO2. Os filmes de TiO2 foram crescidos sobre ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Nanostructured titanium dioxide (TiO2) has been used as a surface modifier in medical implants, promoting improved biocorrosion resistance of the material and increased bioactivity, presenting promising results in the interaction with the living tissue. Despite the biocompatibility of this oxide is recognized, there are still many aspects of the adhesion mechanisms between the proteins and the material surface that are not completely understood. Chemically, the surface of these oxides is mainly terminated by -OH groups which can be readily functionalized. This chemical functionalization or simply a physical modification of the material surface can improve the interaction between the oxide and the biological environment. In addition, titanium dioxide may have the number of hydroxyl groups increased by physical induction under exposure to ultraviolet light. Although this hydroxylation process is less stable, it is possible to increase the number of active sites for a more efficient functionalization. Although the groups generated by this process are thermodynamically less stable, the greater number of active sites available to bound to organic molecules can result in a more efficient functionalization. In this work, the adsorption conformational studies of three different bifunctional molecules, 3-mercaptopropionic acid (MPA), 3-aminopropyltrimethoxysilane (APTMS) and 3-(4-aminophenil) propionic acid (APPA), are presented. These molecules act as spacers in the protein immobiliz... (Complete abstract click electronic access below) / Mestre
79

Influência da incorporação de vidro bioativo em diferentes propriedades de sistemas adesivos /

Costa, Joatan Lucas de Sousa Gomes January 2019 (has links)
Orientador: Alessandra Nara de Souza Rastelli / Resumo: O presente estudo teve como objetivo avaliar o efeito da adição de micropartículas (MPs) de vidro bioativo F-18 em diferentes concentrações em três sistemas adesivos sobre o grau de conversão, a umectabilidade e a resistência adesiva dos mesmos, assim como o padrão de falha. Os sistemas adesivos AdperTM ScotchTM Bond Multi Purpose (A), AdperTM Single Bond (3M ESPE) (S), e Clearfil SE Bond (Kuraray) (C) foram modificados com concentrações de 0 (controle), 1, 2 e 5% de vidro bioativo F-18. Adicionalmente, a distribuição e dispersão das partículas do vidro bioativo foram verificadas por microscopia eletrônica de varredura (MEV). Para o grau de conversão, se obtiveram espectros de absorção dos sistemas adesivos curados e não curados. Para o teste da umectabilidade, os sistemas adesivos modificados ou não foram dispensados sobre as superfícies dentinárias de dentes bovinos, e os ângulos de contato foram mensurados por meio de goniômetro. Para o teste de microcisalhamento, foram confeccionados espécimes em resina composta em substrato bovino, sobre os quais os sistemas adesivos, modificados ou não, foram aplicados, sendo feitas as análises de resistência adesiva após 24 horas. O padrão de falha dos espécimes foi analisado em lupa estereoscópica e por microscopia eletrônica de varredura (MEV). Os resultados foram obtidos e analisados pelo teste de Análise de Variância ANOVA (2 fatores) com pós teste Tukey. Foi observado que não houve diferenças entre os grupos controle e modificados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the effect of the incorporation of F-18 bioactive glass microparticles (MPs) in different concentrations in three adhesive systems on the degree of conversion, wettability and adhesive strength, as well as the failure pattern. Adper™ Scotch™ Bond Multi Purpose, Adper™ Single Bond (3M ESPE), and Clearfil SE Bond (Kuraray) adhesive systems were modified with concentrations of 0 (control), 1, 2 and 5% F-18 bioactive glass. In addition, the distribution and dispersion of bioactive glass particles were verified by scanning electron microscopy (SEM). For the degree of conversion, absorption spectra of cured and uncured adhesive systems were obtained. For the wettability test, adhesive systems modified or not were dispensed on the dentin surfaces of bovine teeth, and the contact angles were measured by goniometer. For the microshear test, specimens were made in composite resin on bovine substrate, on which adhesive systems, modified or not, were applied, and the adhesive strength tests were done after 24 hours. The failure pattern of the specimens was analyzed in a stereoscopic magnifying glass and by scanning electron microscopy (SEM). The results were obtained and analyzed by ANOVA Variance Analysis (2 factors) with Tukey test. It was observed that there were no differences between the control and modified groups (p> 0.05). The predominant failure pattern was adhesive. It was concluded that the addition of F-18 bioactive glass microparticles did not in... (Complete abstract click electronic access below) / Mestre
80

Obtenção de corpos cerâmicos porosos de TiO2 para o emprego como biomateriais / Obtainment of porous ceramic objects of TiO2 for usage as biomaterials

BERTONI, Patrícia Maria Vieira 17 July 2014 (has links)
Este trabalho foi realizado com o objetivo de verificar a viabilidade de obtenção de material cerâmico poroso de TiO2, com características de porosidade específicas para o emprego como biomaterial, através do método de conformação por consolidação com amido. Para tanto, foram confeccionados amostras com diferentes teores de sólidos e com teores de amido variando de 10 a 50%. A escolha do dióxido de titânio deve-se as suas já conhecidas propriedades de biocompatibilidade, pela sua similaridade estrutural com o tecido ósseo, baixo custo e capacidade de esterilização. Os corpos cerâmicos foram pré-sinterizados à 1200°C e sinterizados à 1400°C. A caracterização das peças cerâmicas foi feita por meio do ensaio baseado no princípio de Arquimedes, onde se obteve a densidade aparente, a porosidade e capacidade de absorção das peças. As densidades reais a as perdas de massa foram determinadas durante o processamento do material, ou seja, do corpo à verde, do corpo pré-sinterizado e do corpo sinterizado. A porosidade também foi avaliada por meio de microscopia eletrônica de varredura e por meio do ensaio de líquido penetrante. A caracterização de resistência mecânica foi realizada por meio do ensaio de flexão de três pontos com o objetivo de se nortear o uso do material obtido. O material obtido apresentou porosidade entre 17% a 48%, variando de acordo com o percentual de amido na suspensão. A retração na pré-sinterização à 1200°C ficou em torno de 11% e após a sinterização à 1400°C apresentou valores em torno de 20%. Os poros do material obtido apresentaram diâmetros entre 100цm e 400 цm. Também a interconectividade dos poros pode ser verificada. Sendo assim, a técnica de obtenção adotada se mostrou eficiente na obtenção da porosidade específica para fins biomédicos. / This work was carried out in order to verify the feasibility of obtaining TiO2 porous ceramic material with specific characteristics of porosity for employment as a biomaterial, through the method of shaping by starch consolidation. Thus samples with different solids and starch contents ranging from 10 to 50% were fabricated. The choice of titanium dioxide is due to its well known properties of biocompatibility, due to its structural similarity with bone tissue, low cost and ability to sterilization. The ceramic bodies were pre-sintered at 1200 ° C and sintered at 1400 ° C. The characterization of the ceramic pieces was taken by the essay based on Archimedes' principle, where we got the bulk density, porosity and absorption capacity of the pieces. The actual densities of the mass losses were determined during processing of the material, ie the green body, the pre-sintered body and the sintered body. The porosity was also evaluated by scanning electron microscopy and by means of liquid piercing testing. The characterization of mechanical resistance was performed using the assay of three points in order to guide the use of the material obtained. The material presented porosity from 17 % to 48 %, varying according to the percentage of starch in the suspension. The decrease in pre-sintering at 1200 ° C was around 11 % and after sintering at 1400 ° C showed values ​​around 20 %. The pores of the material obtained had diameters from 100 to 400 цm. Also the pore interconnectivity can be verified. Thus, the technique adopted for obtaining proved effective in obtaining specific porosity for biomedical purposes.

Page generated in 0.1104 seconds