141

[en] METROLOGICAL ANALYSIS OF THE PERFORMANCE OF LIQUID FLOWRATE ULTRA-SONIC METERS AS A DIAGNOSTIC FOR CALIBRATION, INSTALLATION AND OPERATION / [pt] ANÁLISE METROLÓGICA DO DESEMPENHO DE MEDIDORES ULTRA-SÔNICOS DE VAZÃO DE LÍQUIDOS COMO DIAGNÓSTICO DE CALIBRAÇÃO, INSTALAÇÃO E OPERAÇÃO

HELMITOM APARECIDO DA SILVA 28 October 2008 (has links)
[pt] Medidores ultra-sônicos de vazão de líquidos têm sido utilizados cada vez mais em medições fiscais devido à sua baixa incerteza de medição. Esse medidor utiliza a metodologia do tempo de trânsito, o relacionamento entre a velocidade medida e a vazão do escoamento se dá através da garantia de um perfil conhecido de escoamento, normalmente o perfil denominado de completamente desenvolvido. Como na prática existem distorções deste perfil, o uso de vários feixes acústicos pode compensar as discrepâncias, fazendo com que a medição de vazão tenha uma incerteza mais baixa. O Regulamento Nacional, apresentado pela ANP junto com o INMETRO, estipula que os medidores fiscais de vazão de líquidos devem ser calibrados pelo menos a cada 60 dias, a menos que o histórico de medição com os mesmos demonstre que outro intervalo entre calibrações é factível. Recentemente, foi proposto para o medidor ultra- sônico de 5 canais, um intervalo maior (4 anos), associado à garantia de desempenho do medidor e da manutenção do perfil do escoamento entre calibrações. Desse modo, o objetivo desse trabalho é a comprovação experimental de que o diagnóstico de medição e de manutenção do perfil de escoamento é uma ferramenta importante para a garantia de que a vazão de líquido está sendo medida corretamente e dentro dos critérios de medição fiscal estipulados pela legislação em vigor. Para tal, um sistema de aquisição de dados foi acoplado ao medidor ultrasônico de 05 canais, sendo então o medidor calibrado em dois laboratórios acreditados pelo INMETRO e pertencentes à Rede Brasileira de Calibração, respectivamente com água e óleo mineral registrando estes valores de referência, utilizados também para uma comparação entre as características metrológicas dos dois laboratórios. A seguir, o medidor foi instalado numa plataforma, demonstrando que as características metrológicas eram preservadas após sua instalação. Finalmente, um dia de produção da plataforma de origem do medidor foi monitorado, obtendo-se informações sobre a confiabilidade das medições e de sua incerteza. / [en] Ultrasonic flowmeters of liquids have been used each more time in fiscal measurements due to it low uncertainty of measure. That meter uses the methodology of transit time, the relationship between the measured speed and the flow was made through the warranty of flow profile, usually denominated profile of completely developed. As in practice distortions of this profile exist, the use of several acoustic bunches can compensate the discrepancies, doing with that the flow measurement has a lower uncertainty. The Oficial Document of ANP/INMETRO determinated that the fiscal flowmeters of liquids should be calibrated at least every 60 days, unless the measurement report demonstrate that other interval among calibrations is feasible. Recently, a larger interval was proposed for the ultrasonic flowmeter of 5 channels (4 years), associate to the warranty of acting of the meter and of the maintenance of the flow profile among calibrations. The aim of this work is the proof experimental that the measurement diagnosis and maintenance of flow profile is an important tool for the warranty that the liquid flow is being measured correctly and inside of the requirements of fiscal measurement determinated by the actual legislation. This way, a system of acquisition of data was coupled to the ultrasonic flowmeter of 5 channels, then the meter calibrated in two laboratories certified by INMETRO and belong Brazilian Calibration Network, respectively with water and mineral oil registering these reference values, also used for a comparison among the metrological characteristics of the two laboratories. After, the meter was install in a platform, demonstrating that the metrological characteristics was maintains after it installation. Finally, a day of production of the platform was monitored, being obtained information about the reliability of the measurements and of it uncertainty.
142

Monitoração in vivo - análise de incertezas / In vivo monitoring analysis of uncertainties

Santos, Lucas Rodrigues dos 10 April 2012 (has links)
Este trabalho teve como objetivos estabelecer os protocolos para o cálculo de incertezas de medição e a interpretação dos resultados de monitoração do Laboratório de Monitoração In Vivo (LMIV). Especificamente, o trabalho visou quantificar a contribuição dos fatores de influência para o cálculo de incertezas, e estabelecer a incerteza nas medidas. Foram utilizados dois detectores cintiladores de iodeto de sódio ativados com tálio (NaI:Tl) que possuem dimensões de 8x4\" (detector de corpo inteiro) e 3x3\" (detector de tireóide), um analisador multicanal EG&G Ortec, modelo 920E, e um microcomputador onde os espectros são adquiridos, analisados e armazenados com o auxílio do programa Renascence32, Ortec. As medições foram realizadas utilizando-se o objeto simulador antropomórfico do Alderson Research Labs. O radionuclídeo de interesse adotado para este estudo foi o 137Cs. Foram estudadas as influências dos fatores operador, geometria de medição, condições ambientais, flutuações eletrônicas com o tempo e baixa atividade. A análise das incertezas resultou em uma incerteza combinada relativa de 15,7% para o sistema 8x4\" e 9,8% para o sistema 3x3\". Estes valores foram obtidos seguindo os princípios recomendados no Guia para Expressão da Incerteza de Medição (GUM) da Joint Committee for Guides in Metrology (JCGM). / This work aimed to quantify the contribution of influence factors for the calculation of uncertainties and establish the uncertainties in the measurements of the In Vivo Monitoring Laboratory (LMIV). The materials used were used: two scintillator detectors of sodium iodine activated with thallium (NaI:Tl), with the dimension of 8x4\" (whole body detector) and 3x3\" (thyroid detector), an EG&G Ortec, model 920E multichannel analyzer and a microcomputer, where the spectra are acquired, analyzed and stored, with the support of Ortecs software, Renascence32. The measurements were carried out using the anthropomorphic simulating object from Alderson Research Labs. The targeted radionuclide adopted for this study was 137Cs. The influence factors were operator, measurement geometry, environmental conditions and Electronic fluctuations over time. The analysis of the uncertainties resulted in a relative combined uncertainty of 15.7% for the 8x4\" system and 9.8% for the 3x3\" system. These values were obtained following the Guide for Expression of Uncertainty in the Measurement, (GUM) of Joint Committee for Guides in Metrology (JCGM).
143

Sistema de laser de diodo de cavidade estendida para padrões de frequência / Extended cavity diode laser system for primary frequency standards

De Martin Junior, Jair 10 May 2013 (has links)
Este trabalho tem como objetivo principal desenvolver uma nova fonte de laser de diodo compacta e robusta, além de um novo drive de controle para serem utilizados em padrões primário de tempo e frequência tipo chafariz de átomo de Césio e padrões compacto baseados em átomos frios. Um dos requisitos para utilização de laser de diodo em padrões primários de tempo e frequência é sua estabilidade em frequência e baixíssimo ruído espectral. Além disto, dada à aplicação embarcada, o laser deve ser extremamente robusto com relação às condições adversas: mecânicas, térmicas e elétricas. Tanto a parte optomecânica, quanto os controles eletrônicos do novo laser foram desenvolvidos neste trabalho. Vale salientar que tal sistema, em sua concepção, é de grande interesse para diversos outros tipos de aplicação, como espectroscopia de gases (LIDAR), referências em outras frequências e experimentos de física atômica e molecular, que possuem elevados níveis de exigência com relação a ruídos espectrais. / This work has as main objective to develop a new source of diode laser compact and robust, beyond a new drive control for use in primary of time and frequency standards type cesium atom fountain and compact standards-based cold atoms. One of the requirements for the use of diode laser in primary of time and frequency standards are their stability in frequency and are very low spectral noise. Furthermore, given the embedded application, the laser must be extremely robust with respect to adverse conditions: mechanical, thermal and electrical. Both opto-mechanical part, as the electronic controls of the new laser were developed in this work. It is noteworthy that such a system, in its conception, is of great interest to many other types of applications such as spectroscopy of gases (LIDAR), references in other frequencies and experiments of atomic and molecular physics, which have high levels of demand with respect to spectral noise.
144

Estabelecimento de parâmetros operacionais, implementação de ensaio de proficiência e avaliação crítica de métodos analíticos empregados em nutrição animal / Establishment of operationally parameters, proficiency test implementation and analytical methods using in animal nutrition critical evaluation

Souza, Gilberto Batista de 05 September 2007 (has links)
Ensaio de Proficiência para Laboratórios de Nutrição Animal (EPLNA) foi implementado com o objetivo de avaliar a variabilidade dos resultados analíticos e o desempenho de laboratórios de nutrição animal instalados no Brasil. A estrutura e a normatização foram planejadas em conformidade com protocolos internacionais para laboratórios analíticos. São reportados e discutidos os resultados referentes a três anos consecutivos. Participaram do ensaio 43 laboratórios provenientes de instituições de pesquisas estaduais, universidades federais e estaduais e empresas privadas. Foram avaliados os resultados referentes aos ensaios de matéria seca, digestibilidade \"in vitro\" da matéria seca, fibra em detergente ácido, fibra em detergente neutro, proteína bruta, extrato etéreo, lignina, cinzas, nitrogênio não protéico, nitrogênio insolúvel em detergente neutro, nitrogênio insolúvel em detergente ácido e os macro e micro nutrientes (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn e Na). O grupo de amostras utilizadas, com diferentes características físicas e químicas, foi constituído de forrageiras, alimentos concentrados e mistura mineral. Para o estudo dos valores designados foram considerados os valores de consenso dos laboratórios participantes, sendo utilizada a estatística clássica ou robusta para a definição destes parâmetros. Baseado no índice z, o projeto estatístico mostrou-se eficaz para identificar o desempenho dos laboratórios, sendo observado o valor 76,9% como índice de desempenho médio dos laboratórios com conceito satisfatório. Os ensaios referentes às determinações de extrato etéreo, lignina e Na apresentaram maior variabilidade interlaboratorial (cvEE = 42,7%, cvLignina = 59,1% e cvNa = 121,2%), considerando todas as amostras estudadas durante os três anos de avaliação. / Proficiency Testing for Animal Nutrition Laboratories was implemented with the objective to evaluate the variability of the analytical results and the performance of Brazilian animal nutrition laboratories. The structure and normalization were planning in accordance with analytical laboratories international protocols. Three years results are reported and discussed. A number of 43 laboratories, from state researches institutes, federal and state universities, and private companies participated of the trial. The performance of the next trial were evaluated: dry material, digestibility \"in vitro\" of the dry material, acid detergent fiber, neutron detergent fiber, crude protein, ether extract, lignin, ash, non protein nitrogen, insoluble nitrogen in neutron detergent, insoluble nitrogen in acid detergent, and the macro and micronutrients (Ca, P, Mg, K, S, Cu, Fe, Mn, Zn, and Na). The studied sample group, with different physical and chemical characteristics, was composed by forage, concentrate feed, and mineral mixing. To study the designated values, the consensus values provided by the laboratories were considered, and classical or robust statistic was used to define these parameters. The statistical design, based on z score, proved to be adequate to identify the laboratories performance, and the 76.9% value was observed as medium score of the laboratories with satisfactory concept. The ether extract, lignin and Na trials presented higher laboratorial varieties (cvEE = 42.7%, cvLignin = 59.1% e cvNa = 121%), considering the evaluated samples during the considered three years.
145

Desenvolvimento de uma metodologia para calibração de câmaras de ionização de placas paralelas em feixes de raios X de energia baixa em termos de dose absorvida em água / Development of a methodology for calibration of parallel plate ionization chambers for X-ray beams of low energy in terms of absorbed dose to water

Oliveira, Camila Trindade de 10 December 2015 (has links)
O objetivo deste trabalho foi estabelecer uma metodologia de calibração em termos de dose absorvida na água para câmaras de ionização de placas paralelas a serem utilizadas em feixes de radiação X de energia baixa (10 kV a 100 kV) para fins terapêuticos. Atualmente, no Brasil nenhum laboratório de calibração está oferecendo este tipo de serviço. Para o estabelecimento desta metodologia de calibração foram utilizadas duas câmaras de ionização PTW modelos 23344. Ambas as câmaras foram caracterizadas e testadas qualitativamente segundo recomendações de normas internacionais. Os testes de caracterização realizados foram: a medição da taxa de dose mínima efetiva, a curva de saturação, a eficiência da coleção de íons, a resposta quanto ao efeito da polaridade e a linearidade da câmara com a resposta. Os testes de controle de qualidade aplicados foram: estabilidade em curto e longo prazos, fuga de corrente sem irradiação, fuga de corrente após-irradiação e tempo de estabilização. Para a implantação da metodologia, foram estabelecidas as qualidades de radiação de T-10 a T-100, seguindo as recomendações do código de prática da AIEA. Desta forma, foi possível determinar a grandeza de referência, dose absorvida na água, utilizando-se as duas câmaras de ionizações e em todas as qualidades estabelecidas. / The objective of this study was to establish a calibration methodology in terms of absorbed dose to water for parallel plate ionization chambers to be used in low energy X rays beams (10kV to 100kV) for therapy purposes. Currently, in Brazil no calibration laboratory is offering this type of service. In order to establish this calibration methodology was used two ionization chambers PTW models 23344. Both chambers were characterized and tested qualitatively according to recommendations of international standards. The characterization tests performed were: measuring the effective minimum dose rate, the saturation curve, the efficiency of ions collection, polarity effect and the linearity of the ionization chamber with the response. The quality control tests applied were: stability in the short and long term, leakage current without irradiation, leakage current after irradiation and settling time. For the implementation of the methodology, the radiation qualities the T- 10 to T-100 were established, following the recommendations of the IAEA code of practice. Thus, it was possible to determine the magnitude of reference absorbed dose in water, using the two ionization chambers in the all established qualities.
146

Desenvolvimento e caracterização de câmaras de ionização especiais para feixes de tomografia computadorizada / Development and characterization of special ionization chambers for computed tomography beams

Castro, Maysa Costa de 02 May 2016 (has links)
O uso de Tomografia Computadorizada (CT) para procedimentos de imagiologia vem crescendo cada vez mais devido aos avanços da tecnologia dos equipamentos de CT, que permitem a obtenção de imagens com melhor resolução do que por outras técnicas, sendo consequentemente responsável pelo aumento da dose de radiação no paciente durante o procedimento. Isso acarretou uma maior preocupação com as doses recebidas pelos pacientes que se submetem a esse tipo de exame. Para a realização da dosimetria de feixes de CT, o instrumento mais utilizado é a câmara de ionização do tipo lápis, pois este dosímetro apresenta uma resposta uniforme ao feixe de radiação incidente em todos os ângulos. A câmara convencional que se encontra disponível no mercado apresenta um comprimento de volume sensível de 10 cm; entretanto, alguns estudos têm mostrado que esse dosímetro tem subestimado os valores de dose. Portanto, neste trabalho optou-se por desenvolver no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI-IPEN/CNEN) duas câmaras de ionização, fazendo uso de materiais nacionais de baixo custo, com comprimentos de volume sensível de 10 cm e 30 cm. A caracterização destas câmaras foi realizada e os resultados se apresentaram dentro dos limites recomendáveis internacionais. Como uma aplicação, as câmaras desenvolvidas, juntamente com uma câmara comercial, foram testadas em um tomógrafo clínico. As câmaras de ionização desenvolvidas foram analisadas de maneira completa, para os seus possíveis usos. / The use of computed tomography (CT) for imaging procedures is growing due to advances in the CT equipment technology, because they allow the obtention of images with better resolution than through other techniques. Therefore, they are responsible for increasing the dose radiation of patients during the procedure. This fact led to a greater concern about the doses received by patients who undergo this type of examination. To perform the dosimetry in CT beams, the most widely used instrument is the pencil type ionization chamber, because this dosimeter has a uniform response to the incident radiation beam for all angles. The conventional ionization chamber, which is available on the market, has a sensitive volume length of 10 cm; however, some studies have shown that this dosimeter has underestimated the dose values. Therefore, in this study two ionization chambers with sensitive volume lengths of 10 cm and 30 cm, making use of low cost national materials, were developed at the Calibration Laboratory of Instruments (LCI-IPEN/CNEN). The characterization of these chambers was performed, and the results were obtained within the international recommended limits. As an application, the developed ionization chambers and a commercial chamber were tested in a clinical tomographer. The developed ionization chambers were analyzed in a complete way for their possible uses.
147

Análise de incerteza de um sistema automatizado para ensaios de aspersores de irrigação / Analysis of uncertainty of an automated system for testing irrigation sprinklers

Saretta, Ezequiel 17 May 2016 (has links)
Ensaios de distribuição de água de aspersores são convencionalmente realizados manualmente, requerendo tempo e mão de obra treinada. A automação desses ensaios proporciona redução da demanda por esses recursos e apresenta potencial para minimizar falhas e/ou desvios de procedimento. Atualmente, laboratórios de ensaio e calibração acreditados junto a organismos legais devem apresentar em seus relatórios a incerteza de medição de seus instrumentos e sistemas de medição. Além disso, normas de ensaio e calibração apresentam especificação de incerteza aceitável, como a norma de ensaios de distribuição de água por aspersores, ISO 15886-3 (2012), a qual exige uma incerteza expandida de até 3% em 80% dos coletores. Os objetivos deste trabalho foram desenvolver um sistema automatizado para os ensaios de aspersores em laboratório e realizar a análise de incerteza de medição, para sua quantificação nos resultados de ensaio e para dar suporte ao dimensionamento dos tubos de coleta. O sistema automático foi constituído por um subsistema de gerenciamento, por meio de um aplicativo supervisório, um de pressurização e um de coleta, por meio de módulos eletrônicos microprocessados desenvolvidos. De acordo com instruções do sistema de gerenciamento o sistema de pressurização ajustava a pressão no aspersor por meio do controle da rotação da motobomba, e o sistema de coleta realizava a medição da intensidade de precipitação de água ao longo do raio de alcance do aspersor. A água captada por cada coletor drenava para um tubo de coleta, que estava conectado a uma das válvulas solenoides de um conjunto, onde havia um transmissor de pressão. Cada válvula era acionada individualmente numa sequência para a medição do nível de água em cada tubo de coleta, por meio do transmissor. Por meio das análises realizadas, as menores incertezas foram obtidas para os menores diâmetros de tubo de coleta, sendo que se deve utilizar o menor diâmetro possível. Quanto ao tempo de coleta, houve redução da incerteza de medição ao se aumentar a duração, devendo haver um tempo mínimo para se atingir a incerteza-alvo. Apesar de cada intensidade requer um tempo mínimo para garantir a incerteza, a diferença mínima de nível a ser medida foi a mesma. Portanto, para os ensaios visando atender a incerteza, realizou-se o monitoramento da diferença de nível nos tubos, ou diferença de nível, facilitando a realização do ensaio. Outra condição de ensaio considerou um tempo de coleta para 30 voltas do aspersor, também exigido pela norma ISO 15886-3 (2012). A terceira condição considerou 1 h de coleta, como tradicionalmente realizado. As curvas de distribuição de água obtidas por meio do sistema desenvolvido foram semelhantes às obtidas em ensaios convencionais, para as três situações avaliadas. Para tempos de coleta de 1 h ou 30 voltas do aspersor o sistema automático requereu menos tempo total de ensaio que o ensaio convencional. Entretanto, o sistema desenvolvido demandou mais tempo para atingir a incerteza-alvo, o que é uma limitação, mesmo sendo automatizado. De qualquer forma, o sistema necessitava apenas que um técnico informasse os parâmetros de ensaio e o acionasse, possibilitando que o mesmo alocasse seu tempo em outras atividades. / Sprinkler water distribution tests are usually done manually, requiring time and trained labor. Automation of these tests allows saving such resources, and offers potential to minimize failures and/or procedure deviations. Nowadays, calibration and testing laboratories accredited by legal bodies have to present the uncertainty of their instruments and measurement systems. Besides, testing and calibration standards specify acceptable uncertainty, as the standard for sprinkler water distribution test, ISO 15886-3 (2012), which requires an expanded uncertainty up to 3% for 80% of the collectors. The purposes of this work were to develop an automated system for testing sprinkler at laboratory, and perform the analysis uncertainty of measurement, to quantify its magnitude on the testing results, and to support the sizing of collection tubes. The automatic system consisted of a management system, by the supervisory program, a pressurization system, and a collection system, by microprocessed electronic modules developed. According to instructions of the management system, the pressurization system adjusted pressure at the sprinkler by controlling pump rotation, and the collection system measured water application rate through the sprinkler radius. The water from each collector drained to a collecting tube, which was connected to a manifold of valves that contained a pressure transmitter. Each valve was individually triggered in sequence to allow measuring water level within each collection tube, by the transmitter. The analysis of uncertainty showed that the lower diameters of collection tubes presented the lower uncertainty, hence lower diameters should be used when possible. For the collection time, uncertainty decreased as time increased, and should be a minimum value to reach the target uncertainty. Although each application rate requires a minimum time to reach uncertainty, the difference of pressure to be measured stayed the same. Thus, for the tests addressing uncertainty, the difference of pressure was monitored, facilitating the test. Another test condition considered the collection time for 30 laps of the sprinkler, also required by ISO 15886-3 (2012). The third condition considered 1 h of collection, as traditionally done. Water distribution curves obtained from the automated system were similar as those of the conventional tests, for the three situations evaluated. For durations of 1 h or 30 laps of the sprinkler, the automated system required lower total time than the conventional test. However, the system developed demanded more time to perform the test to reach the maximum uncertainty, which is a limitation, even been automatized. In any case, a technician was required just to set parameters and then start the system, so he could allocate his time for other activities.
148

Avaliação da base metrologica para calibração dos sistemas dosimétricos em tomografia computadorizada / Evaluation of a metrological framework for calibrating dosimetric systems of computed tomography

Juliana Viégas Pereira 19 August 2011 (has links)
As grandezas dosimétricas utilizadas em tomografia computadorizada (TC) foram definidas com o objectivo de avaliar as doses de radiação no paciente para fins de otimização e para verificar o desempenho dos equipamentos de TC. Neste trabalho foi estabelecida uma base metrológica para implantação de um procedimento de calibração de sistemas utilizados para dosimetria na área de tomografia computadorizada. Esta base metrológica consistiu na verificação da confiabilidade dos sistemas dosimétricos, na reprodução das qualidades de radiação de referência para feixes de tomografia computadorizada e na implantação da metodologia de calibração de câmaras do tipo lápis e de dosímetros termoluminescentes com a avaliação das incertezas associadas. O trabalho foi realizado no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear (LCD/CDTN), seguindo as indicações do Technical Report Series No. 457, Dosimetry in Diagnostic Radiology: An International Code of Practice TRS457 da Agência Internacional de Energia Atômica (AIEA) de 2007 e da International Electrotechnical Commission, Medical Diagnostic X-ray Equipment Radiation Conditions for use in the determination of characteristics - IEC 61267 de 2005. Os resultados da confiabilidade dos sistemas padrões sugerem que os limites estabelecidos pela IEC 61674 podem estar inadequados para o uso de câmaras de ionização tipo lápis. As radiações de referência RQR e RQT foram estabelecidas dentro dos limites de tolerância de 0,485 à 0,515. A caracterização metrológica de dosímetros termoluminescentes (TL) tem uma importante função na medição de doses em pacientes submetidos a exames de radiodiagnóstico. Os dosímetros termoluminescentes foram calibrados e apresentaram uma incerteza expandida inferior a 25% demonstrando que estão em condições de serem utilizados na dosimetria de pacientes. A câmara de ionização 10X5-3CT foi calibrada no Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares (LCI /IPEN) e no Laboratório do CDTN os resultados dos coeficientes de calibração variaram de 0,3% à 1,3%; isto evidencia a coerência metrológica entre os procedimentos de calibração adotados, já que as diferenças estão dentro das incertezas expandidas de 3,0% e 3,34%, respectivamente. Ao ser comparado o procedimento adotado no CDTN com o procedimento sugerido pelo Código de Prática TRS 457 os resultados dos coeficientes de calibração da câmara lápis apresentaram uma variação de até 6 % e uma incerteza expandia de 2,08%. Os dados obtidos permitem concluir que a base metrológica foi implantada, porém, antes de fornecer o serviço de calibração para a comunidade estudos detalhados no procedimento e comparações adicionais são necessários. / The dosimetric quantities used in computed tomography (CT) were defined to assess radiation doses to the patient for optimization purposes and to verify the performance of CT equipment. This work established a metrological framework for implementing a calibration procedure of systems used for CT dosimetry. The framework was evaluated through the verification of the metrological reliability of dosimetric systems, the reproduction of the reference radiation beam qualities for computed tomography and the implementation of the calibration methodology of the pencil type ionization chambers and thermoluninescent (TL) dosimeters including the evaluation of related uncertainties. The study was conducted at the Laboratory for Calibration of Dosimeters of the Development Center of Nuclear Technology (LCD / CDTN), following the recommendations of the Technical Report Series No. 457, "Dosimetry in Diagnostic Radiology: An International Code of Practice" - TRS457, 2007, of the Agency International Atomic Energy Agency and the International Electrotechnical Commission, "Medical Diagnostic X-ray Equipment - Radiation conditions for use in the determination of characteristics" - IEC 61267, 2005. The results of the reliability of the standard systems suggested that the limits set by IEC 61674 may be unsuitable for the use of pencil type ionization chambers. The reference radiations RQR and RQT were established within the limits of tolerance 0.485 - 0.515. The metrological characterization of TL dosimeters has an important role in the measurement of doses in patients undergoing radiological examinations. The dosimeters were calibrated and showed an expanded uncertainty of less than 25% indicating that they are able to be used in patient dosimetry. The 10X5-3CT ionization chamber was calibrated in the Laboratory Calibration of Instruments of the Institute of Energy and Nuclear Research (LCI / IPEN) and in the CDTN Calibration Laboratory; the difference between the calibration coefficients ranged from 0.3% to 1.3%; this highlights the consistency between the metrological calibration procedures adopted, since differences are within the expanded uncertainties of 3.0% and 3.34%, respectively. The comparison between the calibration procedures adopted by CDTN and suggested by the IAEA TRS 457 Code of Practice showed that the calibration coefficients of the pencil type chamber had a variation of up to 6% with an expanded uncertainty of 2.08%. The obtained data showed that the metrological framework was established; however, detailed studies of the procedure and additional comparisons are still needed before providing calibration service for the community.
149

Desenvolvimento e implantação de um sistema automatizado para adequação do processo de calibração de monitores de radiação gama / Development and implementation of an automated system for adequation of the calibration process for gamma radiation monitors

Iremar Alves da Silva Junior 27 June 2012 (has links)
Esse trabalho foi desenvolvido com a finalidade de melhorar a qualidade dos serviços de calibração e testes de monitores de radiação gama, prestados pelo Laboratório de Calibração de Instrumentos do IPEN, assim como diminuir a dose ocupacional dos técnicos envolvidos no processo de calibração, seguindo os princípios de proteção radiológica. Foi realizado o desenvolvimento e a implantação de um sistema automatizado para o processo de calibração de monitores de radiação gama, constituido por (i) um dispositivo pneumático de troca dos atenuadores e (ii) uma mesa de posicionamento, ambos acionados remotamente por intermédio de um painel de comando. Também fez parte a implantação de um Sistema Irradiador Caesa-Gammatron, que aumentou o intervalo de taxa de kerma no ar, devido sua alta atividade em relação ao sistema atualmente em uso no laboratório de calibração com radiação gama. Para isso, foi necessária a instalação de um dispositivo atenuador controlado remotamente nesse sistema irradiador. Por último foi realizado uma avaliação da redução da dose ocupacional. / This work was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as reducing the occupational dose in technicians involved in the process of calibration, following the principles of radiation protection. In this study it was carried out the development and implementation of a system for adequation of the process of gamma radiation monitors calibration. It is constituted by (i) a pneumatic dispositive to exchange the attenuators and (ii) a positioning table, both actuated through a control panel. System was also implemented. A Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its activity higher than the current system of gamma radiation in use in the calibration laboratory. Hence, it was necessary the installation of remotely controlled in the attenuator dispositive in this irradiator system. Lastly, it was carried out an evaluation in the reduction of the occupational doses.
150

MENIR: método da menor incerteza da massa resultante - uma contribuição para a redução da incerteza da massa de um foguete.

Ricardo Luís da Rocha Carmona 09 December 2005 (has links)
A massa é uma propriedade bastante significativa para diversos cálculos do projeto de um foguete. O custo da massa de um satélite é muito alto e uma diminuição da massa de 1 % pode significar uma economia de milhares de dólares. Então, para se obter um resultado confiável é necessário conhecer as fontes de incerteza que podem influenciar este resultado. Neste trabalho, as principais fontes de incerteza são avaliadas e discutidas, para uma melhor compreensão da complexidade de uma medição de massa de um foguete. Para se obter o resultado com a menor incerteza foi desenvolvido um método de escolha, dentre vários parques de balanças, daquele parque do qual resulta a estimativa da menor incerteza da massa total de um foguete, a partir da medição das massas de seus componentes. O método foi implementado com o uso de planilhas Excel , que podem ser adaptadas para tantas balanças, parques e faixas de massas quantas sejam necessárias, funcionando como ferramenta de auxílio à decisão da estimativa incerteza final do foguete, e norteando decisões como novas aquisições de balanças e contratação de fornecedores de serviço de pesagem.