• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 10
  • 3
  • 1
  • 1
  • Tagged with
  • 464
  • 319
  • 247
  • 98
  • 75
  • 68
  • 67
  • 55
  • 55
  • 40
  • 37
  • 35
  • 31
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
261

[en] ANALYSIS AND FORECASTING OF TIME SERIES USING MULTIPLE SEASONAL EXPONENTIAL SMOOTHING AND SIMULATION TECHNIQUES IN THE WIND ENERGY PRODUCTION / [pt] ANÁLISE E PREVISÃO DE SÉRIES TEMPORAIS UTILIZANDO AMORTECIMENTO EXPONENCIAL COM MÚLTIPLOS CICLOS E TÉCNICAS DE SIMULAÇÃO NA PRODUÇÃO DE ENERGIA EÓLICA

MATHEUS FERREIRA DE BARROS 17 May 2016 (has links)
[pt] A presente dissertação se insere no contexto da energia eólica, que é a fonte de energia que mais cresce na matriz elétrica brasileira, segundo dados da Empresa de Pesquisa de Energia (EPE), com projeções para que esse crescimento se mantenha. Com isso, a principal motivação do presente trabalho é o fato de que desenvolver e aplicar métodos de previsão cada vez mais precisos para as variáveis determinantes na produção de energia eólica em um aerogerador, como a velocidade do vento, é de crucial importância para o planejamento da operação do sistema elétrico nacional. Logo, o objetivo principal do trabalho é adaptar e aplicar uma metodologia de previsão de séries temporais em um banco de dados formado por medições de velocidade de vento. A metodologia se constrói a partir da análise exploratória dos dados, onde pode se observar características importantes, como estacionariedade na média e uma estrutura sazonal complexa, que envolve um ciclo diário e uma sazonalidade mensal. Com isso, foi adaptado um modelo de amortecimento exponencial com múltiplos ciclos que incorpora simulação de Monte Carlo e decomposição da série através do método TBATS, para realizar as previsões. Como resultados e conclusões, é possível observar que modelo adaptado se mostrou adequado para tratar o problema proposto, quando comparado com os modelos de previsão estabelecidos pela literatura, resultando em um aumento na precisão das previsões realizadas. / [en] This work is in the context of wind energy, which is the energy source that grows more in the Brazilian energy matrix, according to the Energy Research Company (EPE), with projections that this growth will continue. Thus, the main motivation of this work is the fact that developing and implementing increasingly precise forecasting methods for the key variables in the production of wind energy in a wind turbine, such as wind speed, is of crucial importance for planning of the national electric system operation. Therefore, the main objective of this work is to adapt and apply a time series forecasting methodology in a database formed by wind speed measurements. The methodology is built from the exploratory analysis of data, which can be observed important features such as stationary mean and a complex seasonal structure, which involves a daily cycle and monthly seasonality. Thus, it was adapted an exponential smoothing model that incorporates multiple cycles, Monte Carlo simulation and decomposition of the series through the TBATS method, to make forecasts. As results and conclusions, it is possible to observe that model adapted was adequate to address the proposed issue, compared with the forecast models established in the literature, resulting in an increase in the accuracy of forecasts made.
262

[en] MEASUREMENT OF ELECTRIC ENERGY CONSUMPTION: ALGORITHM FOR DETECTING POTENTIAL USERS OF THERMO-ACCUMULATION AS AN ALTERNATIVE FOR LOAD SHIFT / [pt] MENSURAÇÃO DO CONSUMO DE ENERGIA ELÉTRICA: ALGORITMO PARA DETECÇÃO DE POTENCIAIS USUÁRIOS DA TERMOACUMULAÇÃO COMO ALTERNATIVA PARA DESLOCAMENTO DE CARGA

PATRÍCIA VALÉRIA SATHLER DE QUEIROZ 30 July 2018 (has links)
[pt] Esta dissertação desenvolveu-se de forma articulada com o projeto de PeD LIGH-ANEEL, coordenado pelo Programa de Pós-Graduação em Metrologia (PósMQI), Projeto Ref. PeD 003/2008, intitulado Racionalização do uso de energia e aplicação da termoacumulação como estratégia para proposição de tarifa diferenciada voltada a clientes comerciais de alto consumo. A dissertação teve como objetivo o desenvolvimento e validação de um algoritmo para identificação de clientes potenciais ao uso da tecnologia de termoacumulação. O trabalho orientou-se no contexto da crescente demanda por energia imposta ao setor elétrico pela expansão da economia, notadamente em horários de alta demanda. A motivação deste trabalho, atendendo aos interesses do PósMQI na área de energia, é oferecer uma ferramenta de auxílio à decisão para o planejamento energético das concessionárias. Como resultado obteve-se o mapeamento das curvas de cargas, obtidas por meio do sistema computacional desenvolvido (SIMCAR). Este sistema (amigável) permite enquadrar os clientes potenciais, segundo características de consumo estruturadas em três categorias indicativas do uso da termoacumulação: muito potencial, potencial e já modula. Dentre as conclusões, o algoritmo desenvolvido mostrou-se ferramenta eficaz de auxílio ao planejamento energético e a termoacumulação uma alternativa sustentável para adequação da matriz energética do país, podendo gerar economias de até 40 porcento. / [en] An algorithm to measure and detect potential thermo-accumulation customers among the clients of a distributing utility was proposed in this work. Such algorithm uses statistical methods for the treatment of missing data and is applied to the measured hourly demands of medium and high voltage customers of the utility. Basically, the thermo-accumulation technique can be defined as a strategy to shift load from peak hours to off-peak hours. The algorithm allows the construction of load curves from the observed load series after the removal of outliers and/or missing values. From the profile of such curves, the algorithm produces the classification of the clients into three possible categories: higly potential, just potential and non potential (i.e. an already modulated client). Also important to mention this dissertation, is part of an R&D project developed for a brazilian southern utility. A friendly computer system named SIMCAR, developed in Visual Basic, implemented the proposed algorithm. As a final word, in surveys conducted with users of this technology, it was mentioned that the savings on energy consumption can be as high as 40 per cent.
263

Metrologia de instrumentos endodônticos por microscopia eletrônica de varredura e análise digital de imagens: uma proposta metodológica / Endodontic instruments metrology by scanning electron microscopy and digital image analysis: a methodological proposal

Marcelo Rolla de Souza 12 February 2008 (has links)
A padronização para a fabricação de instrumentos endodônticos em aço inoxidável contribuiu para o desenvolvimento de novos aspectos geométricos. Surgiram propostas de alterações no desenho da haste helicoidal, da seção reta transversal, da ponta, da conicidade e do diâmetro na extremidade (D0). Concomitantemente, o emprego de ligas em Níquel-Titânio possibilitou a produção de instrumentos acionados a motor, largamente empregados hoje. A cada ano a indústria lança instrumentos com diversas modificações, sem, contudo, disponibilizar informações suficientes quanto às implicações clínicas destas modificações. Existe um crescente interesse no estudo dos diferentes aspectos geométricos e sua precisa metrologia. Tradicionalmente, a aferição de aspectos geométricos de instrumentos endodônticos é realizada visualmente através de microscopia ótica. Entretanto, esse procedimento visual é lento e subjetivo. Este trabalho propõe um novo método para a metrologia de instrumentos endodônticos baseado no microscópio eletrônico de varredura e na análise digital das imagens. A profundidade de campo do MEV permite obter a imagem de todo o relevo do instrumento endodôntico a uma distância de trabalho constante. Além disso, as imagens obtidas pelo detector de elétrons retro-espalhados possuem menos artefatos e sombras, tornando a obtenção e análise das imagens mais fáceis. Adicionalmente a análise das imagens permite formas de mensuração mais eficientes, com maior velocidade e qualidade. Um porta-amostras específico foi adaptado para obtenção das imagens dos instrumentos endodônticos. Ele é composto de um conector elétrico múltiplo com terminais parafusados de 12 pólos com 4 mm de diâmetro, numa base de alumínio coberta por discos de ouro. Os nichos do conector (terminais fêmeas) têm diâmetro apropriado (2,5 mm) para o encaixe dos instrumentos endodônticos. Outrossim, o posicionamento ordenado dos referidos instrumentos no conector elétrico permite a aquisição automatizada das imagens no MEV. Os alvos de ouro produzem, nas imagens de elétrons retro-espalhados, melhor contraste de número atômico entre o fundo em ouro e os instrumentos. No porta-amostras desenvolvido, os discos que compõem o fundo em ouro são na verdade, alvos do aparelho metalizador, comumente encontrados em laboratórios de MEV. Para cada instrumento, imagens de quatro a seis campos adjacentes de 100X de aumento são automaticamente obtidas para cobrir todo o comprimento do instrumento com a magnificação e resolução requeridas (3,12 m/pixel). As imagens obtidas são processadas e analisadas pelos programas Axiovision e KS400. Primeiro elas são dispostas num campo único estendido de cada instrumento por um procedimento de alinhamento semi-automático baseado na inter-relação com o Axiovision. Então a imagem de cada instrumento passa por uma rotina automatizada de análise de imagens no KS400. A rotina segue uma sequência padrão: pré-processamento, segmentação, pós-processamento e mensuração dos aspectos geométricos. / The standardization of stainless steel endodontic instruments has contributed to the development of new geometric features. Many design changes in tip shape, cross section, tapering and diameters have come out. At the same time, the use of Ni-Ti alloys enabled the production of rotary instruments, which are widely employed nowadays. In fact, the industry continuously releases novel instruments with different designs. Nevertheless, not enough information is provided about these modifications and their clinical impacts. Thus, there is a growing interest in the study of these different geometric features and their accurate metrology. Traditionally, the measurement of geometric aspects in endodontic instruments is made visually under an optical microscope. However, this visual procedure is subjective and slow. This work proposes a new method for the metrology of endodontic instruments based on scanning electron microscope (SEM) and digital image analysis. The superior depth of field of the SEM allows the whole relief of an endodontic instrument to be imaged at a constant working distance. Moreover, the images from the back-scattered electrons (BSE) detector have less artifacts and shadows, making the image analysis task easier. In addition, image analysis provides efficient ways of measuring with greater speed and statistical quality. A specific sample holder was adapted for the task of imaging endodontic files. It is composed of a multiple electrical connector, a 12 pole screw terminal strip (4 mm), on an aluminum base covered by gold plates. The holes (female terminals) in the electrical connector have an appropriate diameter (2.5 mm) to fix the endodontic instruments. Besides, the ordered placement of endodontic instruments on the electrical connector allows automating image acquisition in the SEM. The gold plates produce, in BSE images, greater atomic number contrast between the gold background and the instruments. In the built sample holder, the gold plates are in fact gold targets of a sputter coater, because it is a material commonly present in SEM labs. For each file, 4 to 6 adjacent fields at 100X are automatically imaged, to cover its entire length with the required magnification and resolution (3.12 m/pixel). These acquired images are processed and analyzed by AxioVision and KS400 softwares. First, they are assembled in a single extended field image of each instrument by a semi-automated alignment procedure based on cross-correlation in AxioVision. Then, the image of each entire instrument passes through a fully automated image analysis routine in KS400. This routine follows the image analysis standard sequence: pre-processing, segmentation, post-processing and measurement of geometric aspects. The obtained results are consistent with manual measurements but the proposed method is faster. Since assembling 4 to 6 BSE images in an extended field image is the only step that is not fully automated, the proposed method depends much less on the subjectivity of the human operator.
264

[en] DESIGN AND DEVELOPMENT OF A CONTACTLESS AMMETER BASED ON GMR MAGNETOMETERS / [pt] PROJETO E DESENVOLVIMENTO DE UM AMPERÍMETRO SEM CONTATO, POR APROXIMAÇÃO, BASEADO EM MAGNETÔMETROS GMR

CAMILA SCHUINA NEVES 02 October 2018 (has links)
[pt] Amperímetros convencionais devem ser inseridos em série com o elemento no qual se deseja medir a corrente, constituindo uma forma de medição invasiva. Amperímetros alicate, baseados em bobinas, realizam medições de forma não invasiva, mas são limitados a correntes alternadas. Para medição de correntes contínuas, amperímetros baseados no efeito Hall são utilizados, mas possuem baixo nível de tensões de saída e pouca estabilidade em relação à temperatura. O objetivo desta dissertação foi desenvolver um protótipo de amperímetro baseado em magnetômetros de magnetorresistência gigante (GMR) capaz de medir correntes contínuas, de forma não invasiva e com alta resolução em relação aos amperímetros alicate. A metodologia dividiu-se em: (i) utilização de dois magnetômetros GMR para medir o campo magnético gerado pela corrente elétrica em um condutor; (ii) projeto e implementação de um solenoide para polarizar os sensores na faixa de operação linear; (iii) aprimoramento e desenvolvimento de circuitos eletrônicos dedicados à excitação e leitura dos GMRs; (iv) implementação de algoritmos para solução do problema inverso, isto é, a partir da saída do circuito, em mV, estimar a corrente que passa pelo condutor e a distância entre este e o amperímetro. Foram realizados 60 testes, com correntes variando de -3 A a 3 A, com passos de 0,1 A. O protótipo foi capaz de estimar a corrente elétrica com incerteza expandida, do tipo A, de 0,091 A e 0,07 cm para a distância. Os resultados comprovam a viabilidade da realização de medições de corrente, por aproximação, utilizando sensores GMR. / [en] Conventional ammeters should be inserted in series with the element in which the current is to be measured, thus constituting an invasive measurement form. Clamp ammeters, based on coils, are able to measure non-invasively but are limited to alternating currents. For measurement of direct currents, Hall-based ammeters are used, but have low output voltages and little temperature stability. Thus, the objective of this dissertation was to develop a prototype based on giant magnetoresistance (GMR) magnetometers capable of measuring direct currents, non-invasively and with high resolution in relation to clamp ammeters. The methodology was divided into: (i) the use of two GMR magnetometers to measure the magnetic field generated by the electric current in a conductor; (ii) design and implementation of a solenoid to polarize the sensors in the linear operating range; (iii) improvement and development of electronic circuits dedicated to the excitation and reading the GMRs; (iv) implementation of algorithms to solve the inverse problem, that is, from the outputs of the circuit, in mV, estimate the current passing through the conductor and the distance between it and the ammeter. Sixty tests were performed, with currents varying from -3 A to 3 A, with steps of 0.1 A. The prototype was able to estimate the electrical current with type A expanded uncertainty of 0.091 A and 0.07 cm for the distance. The results demonstrate the feasibility of conducting current measurements by approximation using GMR sensors.
265

Padrão de frequência compacto / Compact frequency standard

Stella Torres Muller 30 April 2010 (has links)
Apresentamos os aspectos mais relevantes para a construção e caracterização de um padrão primário de tempo e frequência compacto. Nesse sistema a amostra de átomos de referência é preparada a partir de uma armadilha magneto-óptica. Após a obtenção de uma amostra significativa de átomos os feixes laser são desligados e, durante a expansão livre, a nuvem atômica é submetida a uma sequência de pulsos de micro-ondas que caracterizam o método de Ramsey. Os pulsos de micro-ondas são aplicados em uma cavidade de micro-ondas, esculpida dentro da câmara de vácuo. Todo o ciclo de funcionamento é implementado dentro dessa cavidade e por esse motivo o padrão é considerado compacto. Quando os átomos são interrogados com pulsos de τ = 1 ms separados por Τ = 8 ms obtemos uma largura a meia altura da franja central de 52 Hz e uma estabilidade a curto prazo de 10-13. Alguns causadores de deslocamentos de frequência foram avaliados. / We present some relevant aspects for the construction and characterization of a compact primary frequency standard. In this system, the atomic ensemble is prepared with a magnetooptical trap. Once a significant number of cold atoms is obtained, the laser beams are turned off and, during the free expansion, the cloud is submitted to a sequence of two microwave pulses, characterizing the well-known Ramsey method. The microwave pulses are applied in a microwave cavity that was sculpted inside the vacuum chamber. All the working cycle takes place into this cavity. When the atoms are interrogated by two pulses of τ = 1 ms separated by Τ = 8 ms, the linewidth of the central fringe is 52 Hz and a short-term stability 10-13 is observed. Some frequency shifts were evaluated.
266

Chafariz atômico de Cs 133 / Cs 133 Atomic Fountain

Renato Ferracini Alves 30 March 2012 (has links)
Esta dissertação descreve os recentes desenvolvimentos do Chafariz Atômico localizado no Instituto de Física de São Carlos. Ele consiste de um aparato experimental que provê uma referência de freqüência (e tempo) de altíssima precisão. Para conseguir tal qualidade metrológica, esse sistema trava a freqüência de um oscilador eletrônico, baseado em um cristal de quartzo, na freqüência relativa a uma transição atômica, de uma amostra de átomos resfriados. O átomo utilizado é o 133Cs e a transição utilizada corresponde aos dois níveis hiperfínos do seu estado fundamental. O ciclo de funcionamento é composto por uma etapa de aprisionamento a laser dos átomos e bombeamento óptico, para que todos os átomos se encontrem num mesmo e determinado nível de energia. Esses átomos são então lançados opticamente contra a gravidade através de uma cavidade de microondas. Em trajetória balística e livre de interferências externas, o conjunto de átomos sofre uma possível mudança de estado, dependendo das características de potência e freqüência do sinal de microondas injetado na cavidade. Esta probabilidade de transição é o sinal de erro utilizado para travar em malha fechada o gerador de microondas que alimenta a cavidade. Os melhores resultados obtidos neste experimento foram uma estabilidade de 5x10-12τ-1/2 resultante de um sinal com 3Hz de largura a meia altura (FWHM) da franja central. Fizemos também uma avaliação preliminar dos principais deslocamentos de freqüência e uma análise de interação espacial dos átomos com o campo de microondas. / This paper describes the recent developments of the Atomic Fountain located at the São Carlos Physics Institute. It provides a very high resolution frequency (and time) reference. This is achieved locking an electronic oscillator, based on a quartz crystal, to an atomic resonance of a cold atomic sample. Our laboratory uses the 133Cs atom, using as the referenced transition that corresponds to the two hyperfine energy levels of the ground state. The operating cycle comprises a stage of laser trapping atoms or optical pumping, so that all atoms are within the same atomic state. These atoms are then launched optically against gravity through a microwave cavity. In ballistic trajectory and free from external interference, the set of atoms undergoes a change of state, depending on the power and frequency of the microwave signal injected into the cavity. This transition probability is the error signal used to lock the microwave generator supplying the cavity in a closed loop. The best result obtained in this experiment was a stability of 5x10-12τ-1/2 resulting from signal with a 3 Hz half width (FWHM) of the central fringe. We also provide a preliminary assessment of the main frequency shifts and an analysis of spatial interaction of atoms with the microwave field.
267

Espectroscopia Ramsey em um chafariz atômico / Ramsey Spectroscopy in an atomic fountain

Aida Bebeachibuli 28 November 2007 (has links)
Apresentamos os aspectos mais relevantes para se realizar um chafariz a átomos frios de 133Cs, para operá-lo como um padrão primário de tempo e freqüência para realizar a definição do segundo. O objetivo principal desse trabalho foi a otimização do sistema experimental do chafariz de átomos em duas partes críticas: a região de interação e o sistema de detecção. Além disso, otimizamos as diversas fases da manipulação óptica que fazem parte do ciclo de operação de um chafariz com o intuito de aumentar a relação sinal ruído na região de detecção. Quando os átomos são lançados com uma velocidade de 3,39ms-1, atingem o ápice a 60cm acima da região de captura e passam 360ms na região de vôo livre. A temperatura dos átomos na região de detecção não ultrapassa 15,5K e a diferença de população observada através das Franjas de Ramsey, que são a assinatura característica de um padrão de freqüência atômico, tem a largura a meia altura de 1,4Hz. A largura de linha e a relação sinal ruído da franja implicam em uma estabilidade a curto prazo de 5,18×1012. Alguns causadores de deslocamentos de freqüência como a radiação de corpo negro, o efeito Doppler de segunda ordem, o efeito gravitacional e o efeito Zeeman de segunda ordem foram avaliados. / We present some relevant aspects for the realization of a 133Cs fountain, intended to operate as a primary frequency standard to realize the definition of the second. The main goal of this work is the optimization of the experimental setup of the atomic fountain in its most critical parts: the interaction region and the detection system. Furthermore, the several phases of the optical manipulation which concern the operation cycle of an atomic fountain were also optimized. These procedures allowed us to increase the signal to noise ratio in the detection signal. When the launching velocity is about 3.39 m/s, the atoms reach the apogee about 60 cm above the capture region and spend 360 ms in the free flight zone. The atomic ensemble temperature in the detection region is about 15.5K and the population difference between the two fundamental level is measured through the Ramsey fringe with a linewidth of 1.4 Hz. This linewidth, allied to the obtained S/N resulted in the measured short-term stability of 5.18×1012. Some frequency shift as the black body radiation shift, gravitational shift, second order Doppler shift and second order Zeeman shift were measured.
268

[en] METROLOGICAL CONTROL IN THE PHARMACEUTICAL INDUSTRY: CONTRIBUTION TO MANAGEMENT OF CALIBRATION LABORATORIES OF PROCESS INSTRUMENTS / [pt] CONTROLE METROLÓGICO NA INDÚSTRIA FARMACÊUTICA: UMA CONTRIBUIÇÃO À GESTÃO DE LABORATÓRIOS DE CALIBRAÇÃO DE INSTRUMENTOS DE PROCESSO

WILLIANS DOS ANJOS PINTO PORTELLA 01 August 2005 (has links)
[pt] Contribuindo para o desenvolvimento da confiabilidade metrológica, a presente dissertação de mestrado propõe um modelo integrado de gestão dos padrões metrológicos de referência utilizados na fabricação de medicamentos. Em sintonia às práticas laboratoriais e normas internacionais, o modelo proposto também incorpora o monitoramento de desempenho desses padrões e de instrumentos de processo utilizado entre calibrações sucessivas. O trabalho respalda-se em pesquisa relacionada às práticas correntes de gestão laboratorial conduzida junto a tradicionais laboratórios de calibração de instrumentos de processo da indústria farmacêutica. No contexto de distintas vertentes de análise, o modelo proposto incorpora os seguintes atributos considerados essenciais (i) gestão de padrões metrológicos; (ii) avaliação da relevância da instrumentação de processo para a qualidade; (iii) gestão para tratamento de não- conformidades; (iv) gestão da freqüência de calibração dos instrumentos de processo; (v) gestão da calibração na fabricação e (vi) gestão da calibração na validação de processos críticos de fabricação de medicamentos. A referida pesquisa realizada junto a esse setor de fabricação de medicamentos envolveu 36 laboratórios selecionados dentre aqueles com comprovada experiência e tradição no setor, localizados nos Estados do Rio de Janeiro e de São Paulo, pólo industrial onde se concentram expressiva produção nacional de medicamentos (cerca de 70%). Cada uma das linhas de análise relacionadas aos seis atributos de gestão laboratorial acima mencionados fundamenta-se nos critérios de avaliação: qualidade, produtividade e confiabilidade metrológica. / [en] The development of metrological reliability has received in recent years increasingly attention from metrologists. Confidence in measurements is a prerequisite in the manufacturing of pharmaceutical products The present Master`s Dissertation formulates an integrated managerial model for dealing with metrological reference measuring standards (étalons) used in the pharmaceutical sector. In full compliance with international standards and best laboratory practices, the proposed model incorporates the monitoring of performance of standards and instruments used during two successive calibrations. The work is based on a search related to the best current laboratorial practices developed in connection with laboratorial management in their relation with traditional calibration labs of process instruments operating in the pharmaceutical industry. In this context, the proposed model incorporates the following lines of analysis considered as essential ingredients in the proposed metrological reliability approach: (i) management of metrological standards; (ii) evaluation of the relevance of the process instrumentation for quality control; (iii) management for non-conformity treatment; (iv) management of the frequency of calibration of the process instruments; (v) management of the calibration in the manufacturing process and (vi) management of the calibration in the validation of the critical processes of the pharmaceutical industry. 36 among the most traditional pharmaceutical labs located in the states of Rio de Janeiro and São Paulo - responsible for nearly 70% of all pharmaceutical products in the country - were selected for the survey. For the sake of metrological analyses, each one of the 6 requisites listed above, was based on assessment criteria which included quality, productivity and metrological reliability.
269

[en] METROLOGICAL ASSESSMENT ON PLASMA SPECTROMETRY TECHNIQUE BY ELECTRIC SPARK IN ORDER TO CHARACTERIZE THE STEEL SAMPLES OF CST`S CONTROL PROCESS / [pt] AVALIAÇÃO METROLÓGICA DA TÉCNICA DE ESPECTROMETRIA DE PLASMA POR CENTELHAMENTO ELÉTRICO PARA CARACTERIZAÇÃO DE AMOSTRAS DE AÇO DO CONTROLE DO PROCESSO DA CST

MARCIA SPELTA DE OLIVEIRA 08 March 2006 (has links)
[pt] Esta dissertação de mestrado tem o seu foco no procedimento metodológico para análise de aço realizada no laboratório químico da aciaria da Companhia Siderúrgica de Tubarão para a certificação do produto e do processo. Neste procedimento, utiliza-se um equipamento de espectrometria baseado na emissão da radiação de átomos excitados presentes em um plasma gerado por uma centelha elétrica. O equipamento está configurado para analisar, simultaneamente teores de 18 elementos presentes em uma amostra de aço. O trabalho focou na estrutura de confiabilidade metrológica implantado no laboratório da CST, principalmente quanto ao procedimento de validação de métodos onde foram avaliadas as características de performance: Seletividade, Linearidade, Limite de detecção, sensibilidade, exatidão, precisão (repetitividade, reprodutibilidade) e robustez, conforme descrito no documento normativo do INMETRO (DOQCGCRE- 0008), mostrando assim que o método utilizado é adequado ao uso. Foi também dada uma especial atenção aos parâmetros de controle do equipamento analítico, a luz dos princípios básicos da técnica de espectroscopia de plasma, com o intuito de se avaliar o funcionamento dos sistemas de controle operacional do equipamento. / [en] This masters degree dissertation is focused on the methodological procedure for steel analysis in the chemical laboratory of CSTs steel making plant in order to certify the product and the process. In this procedure, spectrometry equipment is used based on the radiation emission of excited atoms present in plasma produced by electrical spark. The equipment is set to simultaneously analyze the contents of 18 elements present in a steel sample. The task is focused on the metrological reliability structure used by CSTs laboratory and mainly when it comes to the method validation procedure where the following performance characteristics were considered: Selectivity, Linearity, Detection Limit, Sensibility, Accuracy, Precision (repeatibility, reproducibility) and robustness, according to the INMETROs normative document (DOQ-CGCRE- 0008), thus showing that the method is adequate for its use. Special attention was given to the control parameters of the analytic equipment, based on basic principles of plasma spectrometry technique, in order to evaluate the functioning of the equipments operational control system.
270

[en] METROLOGICAL RELIABILITY OF HIGH FREQUENCY SURGICAL EQUIPMENT / [pt] CONFIABILIDADE METROLÓGICA DE UNIDADES ELETROCIRÚRGICAS DE ALTA FREQÜÊNCIA

ROSARIO DEL PILAR ALVA PALOMARES 28 March 2006 (has links)
[pt] A garantia da confiabilidade metrológica de equipamentos médicohospitalares, apesar de essencial para garantir a obtenção do efeito desejado e evitar efeitos adversos, em geral não é realizada durante o período de uso (pós-comercialização). Dentre as principais causas possíveis desta realidade se encontra a falta de informação por parte dos profissionais usuários quanto aos riscos, ou seja, a reduzida cultura metrológica no ambiente da saúde. A partir da identificação de alguns pontos vulneráveis e de graves repercussões na utilização inadequada de bisturis eletrônicos, esta dissertação avaliou parâmetros para a confiabilidade metrológica destes equipamentos, tanto em nível técnico e normativo, quanto em termos da utilização em ambientes hospitalar.Foi realizada uma busca e identificação da normalização nacional, e avaliada a abrangência das normas para garantir de forma completa a utilização dos equipamentos. Os trabalhos práticos para a avaliação metrológica das unidades eletrocirúrgicas foram realizados em três hospitais. Os resultados obtidos auxiliaram na avaliação da confiabilidade metrológica das unidades eletrocirúrgicas em uso, apontando para a necessidade não só de um controle metrológico periódico, como também da inserção de parâmetros de avaliação que não constam na norma aplicável ao equipamento em estudo. Parte desta dissertação foi financiada, através do Convênio referência FINEP n° 22.01.0692.00, pelo Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, um programa cooperativo universidade-empresa. / [en] The metrological reliability of electromedical equipment, although essential in order to guarantee the desired effects and to avoid adverse effects, is often not verified after the equipment is sold and being used (post-sale period). This is partially due to the fact that, usually, health-care takers that use the equipment are unaware of the risks involved, in other words, there is a low metrological culture in the healthcare environment. In this dissertation, vulnerable aspects regarding the inadequate use of high frequency surgical equipment, also known as electrosurgical unit (ESU), were identified, and their consequences evaluated. Based on these results, technical and standard parameters important for the metrological reliability of ESUs, were evaluated. This dissertation also includes a detailed bibliographical research of basic principles, technical specifications, and international procedures that guarantee the metrological reliability of electrosurgical units. The scope of national standards was evaluated in order to guarantee the correct use of all of the ESU´s functions and modes. Experimental data for the metrological evaluation of the EUSs were collected in three (3) hospitals, one (1) private and two (2) public. The results are helpful for evaluating their metrological reliability, and indicate that not only that there is a need for a periodical metrological evaluation, but also that other parameters should be included in existing standards. Part of this dissertation was financed by the Convênio referência FINEP n° 22.01.0692.00 of the Programa Tecnologia Industrial Básica e Serviços Tecnológicos para a Inovação e Competitividade MCT/FINEP/FNDCT/Fundo Verde Amarelo, a universitycompany cooperative program.

Page generated in 0.0474 seconds