• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 207
  • 65
  • 40
  • 23
  • 9
  • 7
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 434
  • 98
  • 62
  • 47
  • 46
  • 43
  • 39
  • 35
  • 30
  • 30
  • 29
  • 28
  • 26
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Micro-concentrateurs de lumière à base de métamatériaux polymères pour la détection infrarouge / Wavelength-scale light concentrators made of polymer metamaterials for infrared applications

Moughames, Johnny 13 July 2016 (has links)
Dans cette thèse, nous développons des micro-concentrateurs de lumière en vue d’applications dans l’infrarouge. Les optiques, plates, de dimensions comparables à la longueur d’onde, sont formées d’une couche micronique de métamatériau, constituée de polymère structuré par des trous d’air. Une focalisation dans la zone de Fresnel des structures est recherchée en réalisant un gradient d’indice, obtenu en variant le diamètre des inclusions d’air (de λ//20 à λ/8). Des simulations électromagnétiques sont d’abord effectuées pour valider un design. La fabrication de ces concentrateurs repose sur la structuration d’une couche de photorésine à l’aide d’une technique de lithographie optique 3D à deux photons. Les mesures obtenues par l’imagerie infrarouge des structures montrent l’obtention d’une focalisation en accord avec les simulations pour un volume de concentrateur de 1,5 λ³, en dépit de l’absorption résiduelle de la résine choisie. Les structures proposées sont invariantes dans la direction axiale et peu épaisses, et peuvent donc être transférées dans d’autres types de matériaux ayant des indices de réfraction plus importants, comme le silicium. Les structures proposées peuvent également servir de plateforme pour réaliser un confinement sub-longueur d’onde par l’ajout d’antennes plasmoniques / In this thesis, we develop flat light concentrators for infrared applications. The structures have dimensions comparable with the wavelength and are made of a metamaterial layer (few microns) made of polymer with air holes inclusions. Light focusing in the Fresnel zone of the structures is achieved by a gradient index profile obained by chirping the holes diameter (from λ//20 to λ/8). Electromagnetic simulations are first performed to validate a design. The fabrication of these concentrators is then made by direct laser writing using a 3D two-photon lithography technique. Infrared imaging of the structures reveals a clear focusing of the infrared light for concentrators volume as small as 1,5 λ³, in agreement with the electromagnetic simulations. Considering that the metamaterial concentrator slabs are invariant in the axial direction and not too thick, similar structures can be transferred in transparent substrates such as silicon using deep reactive ion etching. A subwavelength light confinement can also be exploited by adding plasmonic antenna on the top surface of the flat concentrators
192

Conception, fabrication et caractérisation d'un biocapteur SPR à base de guides d'ondes photoniques sur substrat de verre / Design, fabrication and characterization of an SPR biosensor based on integrated waveguides in a glass substrate

Bonnault, Sandie de 28 June 2016 (has links)
Malgré le nombre croissant de capteurs dans les domaines de la chimie et la biologie, de nombreuses réactions n’ont pas encore été correctement identifiées et étudiées. C’est entre autres le cas des interactions intermoléculaires à l’interface liquide/solide trouvées dans les chimies de surface utilisées pour les méthodes de diagnostics médicaux et l’identification de divers processus biologiques. Afin de correctement comprendre les mécanismes en jeux, il est important de pouvoir croiser différentes méthodes de détection pour obtenir des informations complémentaires.MuLe principal objectif de cette étude est de dimensionner, fabriquer et caractériser un détecteur optique intégré sur verre basé sur la résonance plasmonique de surface, destiné à terme à être combiné avec d’autres techniques de détection. La résonance plasmonique de surface est une technique reconnue pour sa sensibilité adaptée à la détection de surface, qui a l’avantage d’être sans marquage et permet de fournir un suivi en temps réel de la cinétique d’une réaction. L’avantage principal de ce capteur est qu’il a été dimensionné pour une large gamme d’indice de réfraction de l’analyte, allant de 1,33 à 1,48. Ces valeurs correspondent à la plupart des entités biologiques associées à leurs couches d’accroche, particulièrement les matrices de polymères. Ces matrices sont de plus en plus utilisées non seulement pour leur capacité à augmenter la densité d’analytes présents à la surface du capteur, mais aussi pour leurs propriétés favorisant l’adsorption spécifique et leur utilisation comme élément actif de reconnaissance biologique.Étant donné que beaucoup d’études biologiques nécessitent la comparaison de la mesure à une référence ou à une autre mesure, le second objectif du projet est d’étudier le potentiel du système SPR intégré sur verre pour la détection multianalyte.MuLes trois premiers chapitres se concentrent sur l’objectif principal du projet. Le dimensionnement du dispositif suivant un cahier des charges préétabli est présenté, ainsi que les outils de simulation. Le procédé de fabrication de la puce optique sur verre est ensuite décrit, ainsi que les instruments et protocoles de caractérisation. Une comparaison est faite entre les simulations et les résultats expérimentaux, et les performances des outils numériques ainsi que celles du dispositif sont évaluées.Le dernier chapitre de la thèse présente l’étude de plusieurs techniques de multiplexage spectral adaptées à un système SPR intégré, exploitant en particulier la technologie sur verre. L’objectif est de fournir au moins deux détections simultanées. Dans ce cadre, plusieurs solutions sont proposées et les dispositifs associés sont dimensionnés, fabriqués et testés. / In spite of the growing number of available biosensors, many biochemical reactions and biological components have not yet been studied in detail. Among them, some require the combination of several detection techniques in order to retrieve enough information to characterize them fully. An unknown reaction based, for example, on DNA hybridization could be characterized with an electrochemical sensor, a mechanical sensor and an optical sensor, each giving a different type of information.MuThe main objective of the work presented here is to design, fabricate and characterize a flexible integrated optical biosensor based on surface plasmon resonance, intended to be then combined with other detection techniques. Surface Plasmon Resonance (SPR) is well known to be a sensitive technique for surface-based biochemical detection. It has the advantage to be an unlabeled method and provides real time information on the kinetics of a reaction. The use of an integrated technology enables us to integrate several sensors on the same chip for the same sample, making them compact and low-cost. The flexibility of the proposed SPR biosensor comes from the fact that it is designed for a large range of analyte refractive indices, from 1.33 to 1.48 in the 600 nm-1000 nm wavelength range. These values are suitable for most biological entities and their ligand layers, and especially for hydrophilic polymer matrices used to trap DNA or protein entities. These biochemical matrices are used more and more for their ability to trap high densities of analyte, provide a strong binding and serve as an active detection medium with good anti-fouling properties.MuAs several biochemical studies require the simultaneous comparison of measurements to a reference or to another measurement, the second objective of this project is to study the potential of multianalyte detection in an integrated SPR device on glass.The first three chapters of the thesis are focused on the main objective. The design according to predefined specifications is presented, at the same time as the simulation tools. The fabrication process of the glass chip is introduced, as well as the characterization instruments and protocols. Simulation and experimental results are then compared, and the device performance is assessed.The last chapter describes the study of several spectral multiplexing techniques adapted to an integrated SPR system using the glass technology. The goal is to provide at least two simultaneous measurements. Several detection techniques are examined and the related devices are designed, fabricated and characterized.
193

Développement d'un biocapteur couplant la résonance des plasmons de surface et la microcalorimétrie pour le suivi des interactions moléculaires à l'interface liquide/solide

Béland, Rémy 21 November 2013 (has links)
Dans un avenir proche, les dispositifs de détection médicaux miniaturisés en temps réels (lab-on-chip) seront au centre de la révolution des méthodes de diagnostics médicaux et d’identification des processus biologiques et cela, autant au niveau clinique qu’au niveau de la recherche. Pour y arriver, il est important de développer des chimies de surface stables et spécifiques, ce qui demande une compréhension des interactions intermoléculaires à l’interface liquide/solide. Pour bien comprendre ces interactions, il est important de développer des instruments adaptés à la mesure près de l’interface liquide/solide des différentes caractéristiques à identifier. Ce projet de recherche présente la conception, la fabrication et les expériences tests d’un capteur multimodal pour l’identification de processus biologiques à l’interface basés sur des technologies de résonance des plasmons de surface (SPR) et de microcalorimérie. Ces deux technologies mises ensemble vont permettre d’effectuer des mesures de la cinétique des interactions ainsi que des caractéristiques thermodynamiques. En premier lieu, les caractéristiques d’une interaction intermoléculaire à l’interface d’une réaction d’hybridation d’ADN furent définies afin d’en déduire un cahier des charges pour les transducteurs. Suite à cela, la conception des transducteurs microcalorimétrique et SPR furent réalisés en tenant compte des contraintes de chacun des transducteurs. Suite à la conception théorique des différentes parties du capteur, un procédé de fabrication compatible avec les méthodes de fabrication standard de la microélectronique fut défini et testé. Afin de s’assurer de la fonctionnalité des dispositifs ainsi fabriqués, des tests de fonctionnalisation de surface furent appliqués sur les échantillons afin de tester la compatibilité du procédé de fonctionnalisation avec les méthodes de fabrication et avec une chimie de surface type. Pour terminer, un système de mélange actif fut testé et caractérisé avec le dispositif de microcalorimétrie afin de s’assurer qu’il était possible de mélanger les fluides avec les produits biologiques pour s’assurer de la qualité de la réaction de surface. Le système développé pourra être utilisé pour effectuer la mesure d’hybridation d’ADN à l’interface. Le système intègre deux modalités permettant la caractérisation en temps réel des interactions intermoléculaires à l’interface liquide/solide. Ce type de système permet la mesure de la cinétique de différents modèles biologiques tels que les puces à sucre encore certains récepteurs cellulaires ou la mesure de conformation moléculaire à l’interface. Des mesures d’oxydation du glucose catalysée par la glucose oxydase sont montrées. / To begin with, the characteristics of a DNA hybridization intermolecular interaction at the interface were defined in order to deduce the specifications for our transducers. Following this, the SPR and microcalorimetric transducer will be design by taking into account the constraints of each one. Following the theoretical design of the sensor, a manufacturing process compatible with standard methods of microelectronics manufacturing was tested and identified. To ensure the functionality of the devices, a test of surface functionalization on the sensor was applied to test the compatibility of the manufacturing process with the surface functionalization methods. Finally, a system of active mixing was tested and characterized with a microcalorimetric device to ensure it was possible to mix fluids with organic products to be sure of the quality of the surface reaction. The system developed can be used to mesure DNA hybridization at the interface. This system incorporates two modalities for real-time characterization of intermolecular interactions near the solid/liquid interface. This type of system allows the kinetic measurement of different biological models such as cellular receptors or it is possible to have some molecular measure conformation near the interface. Oxidation of glucose with the enzyme glucose oxidase was shown to present the possibility to measure a biological interaction.
194

Dynamique de la fermeture des trous épithéliaux en utilisant des techniques de micromécanique et de microfabrication / Dynamics of epithelial gap closure using microfabrication and micromechanical approaches

Anon, Ester 05 October 2012 (has links)
Les cellules peuvent migrer sous différentes conditions qui dépendent de l’environnement biochimique ou mécanique. Connaître les mécanismes de la migration, les protéines impliquées et leur régulation est essentiel pour comprendre les processus de morphogénèse ou certaines situations pathologiques. Dans ce contexte, la migration collective des cellules est un processus clé qui intervient pendant le développement ainsi que dans la vie adulte. Elle joue un rôle très important pour la formation et l’entretien des couches épithéliales, notamment au cours du développement embryonnaire et pendant la cicatrisation des trous épithéliaux résultant, par exemple, d’une blessure. Lorsque l’épithélium présente une discontinuité, des mécanismes actifs qui impliquent une migration coordonnée des cellules sont nécessaires pour préserver l’intégrité des tissus. Dans ce travail, nous avons étudié les mécanismes impliqués dans la fermeture des trous dans un épithélium. Pour des blessures de faible taille, le mode de fermeture dit de purse string est souvent évoqué, impliquant la contraction d’un anneau contractile d’acto-myosine qui ferme la blessure. Pour des blessures de tailles plus importantes, il est courant d’observer un mécanisme différent conduisant { la migration active des cellules du bord qui couvrent la surface “libre”.Pour étudier ces aspects de manière quantitative et reproductible, nous avons développé une nouvelle méthode basée sur des techniques de microfabrication et de lithographie dite « molle » qui permet de faire une étude quantitative de la fermeture des trous épithéliaux. Nous avons fabriqué des substrats de micropiliers de diamètre et de forme variés dans les quels les cellules sont libres de pousser entre les microstructures. Lorsqu’elles sont parvenues à confluence, on retire le substrat qui laisse apparaître des trous contrôlés.De cette manière, nous avons observé que les cellules épithéliales forment des lamellipodes pour la fermeture de ces trous. Le mécanisme de fermeture dépend de la taille des trous et nous avons pu observer différents régimes en fonction de diamètre des piliers. Les trous petits (de la taille d’une seule cellule) sont fermés par un mécanisme passif alors que la fermeture de trous plus larges nécessite un mécanisme actif de migration conduisant à la formation de lamellipodes et à des modes de migration collective. Par la suite, nous nous sommes intéressés à l’aspect mécanique de la fermeture des trous épithéliaux. Pour cela, nous avons utilisé un système d’ablation laser pour rompre quelques cellules dans une monocouche épithéliale. Nous avons alors mesuré les forces de traction que les cellules exercent au substrat et leur évolution temporelle et spatiale. Nous avons pu mettre en évidence différents modes de traction: au début, les cellules exercent des forces de traction importantes sur leur substrat pour laisser place à des contraintes mécaniques qui sont davantage issues d’un processus collectif au travers de la formation d’un câble multicellulaire qui les relie les cellules de bord entre elles. En conclusion, ce travail nous a permis d’obtenir des informations sur les mécanismes dynamiques de fermeture des tissus épithéliaux qui sont évidemment impliqués dans la cicatrisation des blessures mais aussi dans certains problèmes de malformations congénitales lors l’embryogenèse. / Most cells migrate under the appropriate conditions or stimuli; understanding the mechanisms of migration, the players involved, and their regulation, is pivotal to tackle the pathological situations where migration becomes an undesired effect. While largely overshadowed by the study of single cell migration, collective cell migration is a very relevant process that takes place during development as well as in adult life. Collective migration is very relevant for the formation and maintenance of epithelial layers: extensive migratory processes occur during the shape of the embryo, as well as during the healing of a skin incision in the adult. When openings or discontinuities appear in the epithelia, it is crucial that the appropriate mechanisms are activated.In the present work we attempt at deciphering what are the mechanisms involved in gap closure. Until now, most of the literature concerning the subject has reported contradictory results, mainly arising from the complexity of the process and the lack of systematic analysis. We have designed a novel approach to address epithelial gap closure under well-defined and controlled conditions. By using our gap patterning method, we have observed that epithelial cells extend lamellipodia when exposed to a newly available space. Interestingly, we found that the closure of such gap depends on the size: small gaps are closed by a passive physical mechanism, while large gaps are closed through a Rac-dependent cell crawling mechanism, in a collective migration-like manner. 11Abstract (English)Most cells migrate under the appropriate conditions or stimuli; understanding the mechanisms of migration, the players involved, and their regulation, is pivotal to tackle the pathological situations where migration becomes an undesired effect. While largely overshadowed by the study of single cell migration, collective cell migration is a very relevant process that takes place during development as well as in adult life. Collective migration is very relevant for the formation and maintenance of epithelial layers: extensive migratory processes occur during the shape of the embryo, as well as during the healing of a skin incision in the adult. When openings or discontinuities appear in the epithelia, it is crucial that the appropriate mechanisms are activated.In the present work we attempt at deciphering what are the mechanisms involved in gap closure. Until now, most of the literature concerning the subject has reported contradictory results, mainly arising from the complexity of the process and the lack of systematic analysis. We have designed a novel approach to address epithelial gap closure under well-defined and controlled conditions. By using our gap patterning method, we have observed that epithelial cells extend lamellipodia when exposed to a newly available space. Interestingly, we found that the closure of such gap depends on the size: small gaps are closed by a passive physical mechanism, while large gaps are closed through a Rac-dependent cell crawling mechanism, in a collective migration-like manner. Next, we also addressed the mechanical component of epithelial gap closure. In this study, we took advantage of a laser-ablation system to disrupt some cells within an epithelial monolayer, and study how the remaining cells sealed that gap. By measuring the traction forces that cells exert on the substrate along the closure, we observed that cells first pulled on the substrate to propel themselves. By the last steps of closure, there is a transition in the direction of the force, so that cells are pulled to the center of the gap due to the assembly of a supracellular actin cable. Altogether, this work provides valuable knowledge on the current understanding of the mechanisms accounting for epithelial gap closure. We believe that a better comprehension of these mechanisms can help to shed light in clinically relevant situations where epithelial gap closure is impaired.
195

Synthèse de générateurs de photoacides activables par absorption biphotonique pour la microfabrication à trois dimensions / Synthesis of two-photon activable photoacid generators for three dimensions microfabrication

Vergote, Thomas 03 June 2014 (has links)
Depuis les années 60, la génération d’acide fort de Brönsted par un processus photoinduit à un photon est utilisée dans des nombreux domaines de recherche de plus en plus nombreux. Cependant, de tels acides peuvent-être facilement obtenus par voie biphotonique ce qui présente de nombreux avantages comme par exemple : une meilleure réactivité via une excitation direct du photoacide, l’utilisation possible d’une atmosphère non contrôlée, l’utilisation de microlasers à impulsions sub-nanosecondes peu couteux, mais aussi l’augmentation de la résolution spatiale des micro-objets 3D fabriqués. La génération d’acide se fait généralement par transfert d’électron entre un sensibilisateur et un générateur de photoacide (PAG). Une approche prometteuse consiste à associer, sur une même molécule, un PAG et un chromophore actif à deux photons. Il a donc semblé intéressant de développer de nouveaux PAG capables, par excitation biphotonique, d’amorcer directement la photopolymérisation. Nous avons choisi de préparer des systèmes capto-datifs stilbéniques, de nature neutre ou ionique. Aussi, une série de PAG neutres substitués par des groupements diphénylamino- donneur et iminosulfonates -cyanés accepteurs a été synthétisée. Nous avons également commencé, mais non achevé, la synthèse de PAG neutres portant des groupements iminosulfonates -trifluorométhylés. Puis, nous avons cherché à synthétiser des PAG ioniques substitués soit par un groupement éthoxy soit par un groupement diphénylamino soit par un groupement julolidine. Néanmoins, la dernière étape de la synthèse est pour l’instant un verrou synthétique. / Since the 60’s, the generation of strong Brönsted acids by a one-proton photoinduced process has been used in more and more research areas. Recently, it has been shown, that such acids are easily obtained by a two-photon process. This offers many advantages such as: i) a better reactivity owing to a direct excitation of the photoacid, ii) the possible use of a non-controlled atmosphere, iii) the use of inexpensive microlasers with sub-nanosecond impulsions, iv) the increase of spatial resolution in 3D microfabrication. The acid generation generally proceeds through a photo-induced electro transfer from an excited sensitizer to the photoacid generator (PAG). A promising approach should be the introduction on a single molecule of both a PAG and a two-photon active chromophore moiety. In this context, we have developed new PAGs able to initiate photopolymerisation through a two-photon activation process. The syntheses were focused on stilbenic push-pull systems having either a neutral or an ionic nature. A series of neutral PAGs bearing a diphenylamino donor group and an α-cyano iminosulfonate acceptor moiety has been synthesized. The preparation of neutral PAGs bearing iminosulfonate α-trifluoromethylated groups were not yet completed. The syntheses of ionic PAGs substituted by an ethoxy group, a diphenylamino group or a julolidine one, could not be completed either.
196

Perforated Hollow Core Waveguides for Alkali Vapor-cells and Slow Light Devices

Giraud Carrier, Matthieu C 01 February 2016 (has links) (PDF)
The focus of this work is the integration of alkali vapor atomic vapor cells into common silicon wafer microfabrication processes. Such integrated platforms enable the study of quantum coherence effects such as electromagnetically induced transparency, which can in turn be used to demonstrate slow light. Slow and stopped light devices have applications in the optical communications and quantum computing fields. This project uses hollow core anti-resonant reflecting optical waveguides (ARROWs) to build such slow light devices. An explanation of light-matter interactions and the physics of slow light is first provided, as well as a detailed overview of the fabrication process. Following the discovery of a vapor transport issue, a custom capillary-based testing platform is developed to quantify the effect of confinement, temperature, and wall coatings on rubidium transport. A mathematical model is derived from the experimental results and predicts long transport times. A new design methodology is presented that addresses the transport problem by increasing the number of rubidium entry points. This design also improves chip durability and decreases environmental susceptibility through the use of a single copper reservoir and buried channel waveguides (BCWs). New chips are successfully fabricated, loaded, and monitored for rubidium spectra. Absorption is observed in several chips and absorption peaks depths in excess of 10% are reported. The chip lifetime remains comparable to previous designs. This new design can be expanded to a multi-core platform suitable for slow and stopped light experimentation.
197

Deterministically engineered, high power density energy storage devices enabled by MEMS technologies

Armutlulu, Andac 07 January 2016 (has links)
This study focuses on the design, fabrication, and characterization of deterministically engineered, three-dimensional architectures to be used as high-performance electrodes in energy storage applications. These high-surface-area architectures are created by the robotically-assisted sequential electrodeposition of structural and sacrificial layers in an alternating fashion, followed by the removal of the sacrificial layers. The primary goal of this study is the incorporation of these highly laminated architectures into the battery electrodes to improve their power density without compromising their energy density. MEMS technologies, as well as electrochemical techniques, are utilized for the realization of these high-power electrodes with precisely controlled characteristic dimensions. Diffusion-limited models are adopted for the determination of the optimum characteristic dimensions of the electrodes, including the surface area, the thickness of the active material film, and the distance between the adjacent layers of the multilayer structure. The contribution of the resultant structures to the power performance is first demonstrated by a proof-of-concept Zn-air microbattery which is based on a multilayer Ni backbone coated with a conformal Zn film serving as the anode. This primary battery system demonstrates superior performance to its thin-film counterpart in terms of the energy density at high discharge rates. Another demonstration involves secondary battery chemistries, including Ni(OH)2 and Li-ion systems, both of which exhibit significant cycling stability and remarkable power capability by delivering more than 50% of their capacities after ultra-fast charge rates of 60 C. Areal capacities as high as 5.1 mAh cm-2 are reported. This multilayer fabrication approach is also proven successful for realizing high-performance electrochemical capacitors. Ni(OH)2-based electrochemical capacitors feature a relatively high areal capacitance of 1319 mF cm-2 and an outstanding cycling stability with a 94% capacity retention after more than 1000 cycles. The improved power performance of the electrodes is realized by the simultaneous minimization of the internal resistances encountered during the transport of the ionic and electronic species at high charge and discharge rates. The high surface area provided by the highly laminated backbone structures enables an increased number of active sites for the redox reactions. The formation of a thin and conformal active material film on this high surface area structure renders a reduced ionic diffusion and electronic conduction path length, mitigating the power-limiting effect of the active materials with low conductivities. Also, the highly conductive backbone serving as a mechanically stable and electrochemically inert current collector features minimized transport resistance for the electrons. Finally, the highly scalable nature of the multilayer structures enables the realization of high-performance electrodes for a wide range of applications from autonomous microsystems to macroscale portable electronic devices.
198

Étude du couplage adiabatique entre deux guides d'ondes ayant une forte différence d'indice de réfraction

Bédard, Sylvain January 2009 (has links)
Ce document présente les étapes de fabrication ainsi que la caractérisation d'un coupleur optique composé de deux guides d'ondes d'indice de réfraction éloigné. Le guide d'ondes avec le plus fort indice de réfraction est en Silicium (Si) d'indice de réfraction de 3,44 et celui de plus faible indice est fait de SU-8(TM) dont l'indice de réfraction est de 1,565. La principale caractéristique du coupleur est sa géométrie. Le couplage se fait par une approche progressive des deux guides d'ondes. Le guide d'onde de SU-8(TM) progresse vers le guide de Si en empruntant un rayon de courbure constant dans la zone de couplage pour finalement superposer le guide de Si lorsque les parcours optiques sont parallèles. Par l'approche progressive, le transfert optique se fera de façon adiabatique. Une étude numérique a montré qu'il était possible d'atteindre un coefficient de couplage de plus de 30%. Bien que les résultats expérimentaux ne soient pas aussi encourageants, ils montrent la présence non négligeable de couplage.
199

Réalisation de sources lumineuses à haut rendement lumen /$ à base d'hétérostructures GaN/AlGaN

Leulmi, Rym Feriel January 2009 (has links)
Depuis quelques années, une révolution est en cours dans l'industrie des semiconducteurs de type III-V. Les composés azotés, comme le GaN et l'AlGaN ont permis l'apparition de nouvelles sources de lumière bleue, blanche et ultra-violette. Les sources blanches, plus particulièrement, possèdent un impressionnant potentiel commercial, car elles permettront de pénétrer l'immense marché de l'éclairage domestique et industriel. On peut déjà observer leur apparition dans l'industrie de l'automobile (éclairage de tableau de bord, phares de jour), de la signalisation routière (feux de circulation), et la téléphonie cellulaire (éclairage arrière des touches et de l'écran). En effet, les diodes électroluminescentes (DELs) blanches, fabriquées à base de GaN démontrent déjà une efficacité énergétique (en lumens/Watt) qui surpasse les technologies traditionnelles comme les ampoules incandescentes et les tubes fluorescents [IEA, 2006]. Cependant, plusieurs problèmes technologiques limitent l'efficacité des DELs, notamment l'expertise dans la fabrication du GaN. Il s'agit d'une technologie ayant une faible maturité notamment en comparaison avec les autres composés III-V à base de GaAs et InP utilisés traditionnellement dans les télécommunications. De plus, l'indice de réfraction élevé du matériau empêche plus de 93% des photons générés de s'échapper du dispositif, diminuant d'autant l'efficacité. Plusieurs méthodes d'optimisation de la luminosité des DELs sont disponibles dans la littérature. Le détachement du substrat et le collage de la diode à l'envers sur un matériau conducteur est une des méthodes exploitées. Ces méthodes, souvent trop dispendieuses à cause de leur complexité, ont néanmoins démontré un grand potentiel d'amélioration de l'efficacité des dispositifs à base de GaN. L'objectif du projet consiste à développer un procédé de fabrication de DELs bleues dans le but d'augmenter considérablement (x 3) l'intensité lumineuse émise par rapport à des approches de fabrication standard et en utilisant des approches de fabrication à faible coût. Ce document présente une revue de littérature du sujet, de ses problématiques, des objectifs de projet en cours et des méthodes à mettre en oeuvre pour les réaliser dans un délai prescrit.
200

Développement d'une technologie NMOS pour la conception de fonctions électroniques avancées

Bérubé, Benoit-Louis January 2010 (has links)
Ce mémoire de maîtrise présente le développement d'une technologie NMOS utilisée en enseignement au 1er et 2e cycle et comme preuve de concepts en recherche à l'Université de Sherbrooke. Le développement est basé sur la technologie JOPE à 6 masques utilisée en enseignement depuis les années 90. Le but de ce projet est d'optimiser ce procédé pour augmenter la reproductibilité des circuits et la densité d'intégration. Les problèmes de JOPE sont une forte résistivité de couche du polySi, une grande résistivité des contacts aluminium/polySi et aluminium/zone active ainsi qu'une grande fluctuation de la tension de seuil des transistors. Le procédé de fabrication JOPE a été optimisé pour créer JOPE2 afin d'améliorer les propriétés physiques des composantes et atteindre les objectifs fixés. Des circuits ont été fabriqués contenant des structures de caractérisations et des circuits numériques et analogiques conçus avec une règle de longueur de grille minimale de 2 [micro]m. La résistivité du polySi de JOPE2 est diminuée d'un facteur 5 en augmentant la température de déposition de la couche par LPCVD et en ajoutant une implantation ionique dédiée en plus de celle déjà prévue avec le procédé autoaligné pour les sources/drains. De cette façon, la résistivité des contacts aluminium à polySi est diminuée d'un facteur 10. La résistivité des contacts aluminium à zone active est diminuée d'un facteur 20 en augmentant la dose d'implantation ionique des sources/drains. JOPE2, tout comme JOPE, présente une variation importante de la tension de seuil causée par les charges d'interfaces Si/SiO[indice inférieur 2] et la variation de la résistivité du substrat utilisée (1 à 10 [oméga]-cm). Le faible rendement du procédé, évalué à 47 %, est causé par la faible stabilité des contacts, la grande densité de défauts et les limitations en ce qui a trait à l'alignement des masques. Pour faire suite à ce projet, un procédé NMOS à 3 [micro]m est recommandé afin d'augmenter le rendement en diminuant l'impact des défauts, améliorant la stabilité des contacts et en augmentant la qualité de l'alignement. De plus, pour augmenter la stabilité de la tension de seuil il est recommandé d'utiliser des tranches hautes résistivité. Le procédé recommandé devrait permettre de fabriquer des circuits complexes basés sur des transistors NMOS avec un rendement de 80 %.

Page generated in 0.0794 seconds