• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 151
  • 84
  • 45
  • 14
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 353
  • 85
  • 48
  • 45
  • 37
  • 37
  • 30
  • 29
  • 18
  • 15
  • 15
  • 14
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Eco-extraction et analyse de lipides de micro-algues pour la production d'algo-carburant / Eco-Extraction and analysis of lipid from microalgae for the production of biodiesel

Dejoye, Céline 12 November 2013 (has links)
La biodiversité des micro-algues constitue un réel potentiel pour la recherche et l’industrie. En comparaison des plantes terrestres, elles sont une piste prometteuse pour les biocarburants. Néanmoins, un certain nombre de verrous technologiques restent à lever comme l’extraction de l’huile algale. L’objectif de cette thèse a donc consisté en l’innovation et le développement de nouvelles méthodologies dits « vertes » d’extraction de lipides de micro-algues pour une application biocarburant.La première partie de ce manuscrit propose une alternative à l’utilisation de solvants pétrochimiques (n-hexane) pour l’extraction des lipides à partir d’une biomasse sèche grâce aux solvants terpéniques d’origine végétale.Ces résultats encourageants ont permis dans une seconde partie de s’orienter vers le développement d’une technique permettant l’extraction des lipides de micro-algues humides (80% d’humidité) par des solvants terpéniques : le SDEP (Simultaneous Distillation and Extraction Process).Afin d’accélérer le processus d’extraction, dans la troisième et dernière partie de ce travail les micro-ondes ont permis d’intensifier ce procédé. Les micro-ondes permettent un échauffement rapide de l’eau environnante et contenue dans les cellules impliquant ainsi une libération rapide du contenu cellulaire vers le milieu extérieur. Ce travail a consisté en l’intensification et l’optimisation de cette technique d’extraction (SDEP) destinée à l’extraction des lipides à partir de micro-algues humides : le SDEP assisté par micro-ondes. L’appareillage permet des extractions rapides, non destructrices et généralisables à différentes espèces de micro-algues discutées dans cette troisième partie / The biodiversity of microalgae is a real potential for research and industry. Compared to terrestrial plants, they are a promising route for biofuels. Still, a number of technological locks is to lift as the the algal oil extraction. The objective of this thesis has consisted of innovation and development of new methodologies, so-called “green” extraction of lipid of microalgae for biofuel application.The first part of this manuscript proposes an alternative to the use of petrochemical solvents (n-hexane) extraction of lipids on a dry biomass with terpene solvents from plant origin.These encouraging results have allowed in a second part of move towards the development of a technique for the extraction of lipids of wet microalgae (80% of humidity) by terpene solvents; the SDEP (Simultaneous Distillation and Extraction Process).To accelerate the process of extraction, in the third and final part of this work the microwaves have allowed to intensify this process. Microwave allow a fast heating of water surrounding and contained in cells thus implying a rapid release of the cell contents into the environment. Our work consisted in the intensification and optimization of the extraction technique (SDEP) intended for the extraction of lipids from wet microalgae: SDEP assisted by microwaves. The apparatus allows rapid and non-destructive extractions that can be generalizable for different species of microalgae discussed in this third part
202

Esterelização de esmalte bovino por meio de irradiação por microondas: efeito sobre a microdureza superficial e resistência à desmineralização

Viana, Patricia Gabriela Sabino [UNESP] 27 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-27Bitstream added on 2014-06-13T19:17:33Z : No. of bitstreams: 1 viana_pgs_me_arafo.pdf: 840842 bytes, checksum: 18e582ab40c3b9552459a495ba07430b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Amostras de esmalte provenientes de dentes extraídos, de origem humana ou bovina, são amplamente utilizadas em estudos realizados in vitro e in situ. Esses dentes são considerados uma fonte em potencial de microorganismos patogênicos e devem ser esterilizados, antes da sua utilização nas pesquisas, para prevenir a ocorrência de infecções cruzadas. No entanto, o processo de esterilização do esmalte não deve alterar a sua integridade estrutural. O presente estudo teve como objetivo avaliar a efetividade da irradiação por microondas na esterilização do esmalte bovino, assim como o efeito deste método sobre a microdureza superficial e resistência à desmineralização do esmalte bovino. Dezoito incisivos bovinos foram utilizados para a obtenção de quarenta amostras de esmalte, divididas em dois grupos (n=20): controle (não-irradiados) e irradiados por microondas (3 minutos a 650 W). As amostras do grupo irradiado foram imersas, individualmente, em 200 mL de água destilada e submetidas à irradiação por microondas por 3 minutos a 650 W. Em seguida, ambos os grupos tiveram suas amostras imersas individualmente em tubos estéreis contendo 10 mL caldo BHI (Brain Heart Infusion), os quais foram incubados por 7 dias a 37°C, sob condições de aerobiose e anaerobiose. Após a incubação, o desenvolvimento de microorganismos foi verificado pela presença de turvação do meio de cultura. Em seguida, foram realizadas diluições seriadas (10-2 a 10-5), plaqueamento em meio ágar sangue e incubação em condições de aerobiose e anaerobiose, durante 48 h e 7 dias, respectivamente. Os valores de unidades formadoras de colônias foram calculados. Para a avaliação das propriedades do esmalte, outras 18 amostras de esmalte (4 x 4 mm) foram preparadas, individualmente embutidas em resina acrílica, seqüencialmente polidas e, então, seccionadas em duas metades, sendo uma das metades... / Enamel samples from bovine or human teeth are routinely used for in vitro and in situ caries research. These enamel samples need to be sterilized before they can be used in intra-oral appliances and the sterilization method must not affect the structural integrity of the tooth. The aim of this study was to evaluate the effectiveness of microwave irradiation on bovine enamel sterilization, as well as it's effect on the surface microhardness and resistance to demineralization of bovine enamel. Eighteen bovine incisors were used to produce forty enamel samples, divided in two groups (n = 20): control (nonirradiated) and microwave irradiated (3 minutes at 650 W). Microwaving samples were individually immersed in 200 mL of distilled water and submitted to irradiation at 650 W for 3 minutes. Following the microwaving, specimens from both groups were added individually to 10 mL of Brain Heart Infusion broth in sterile test tubes, which were incubated at 37°C for 7 days under aerobic and anaerobic conditions. After 7 days incubation, those test tubes in which turbidity was observed were considered to contain growing microorganisms. Dilutions of 10-2 to 10-5 were performed on blood agar plates, which were incubated aerobically and anaerobically for growth for up to 48 h and 7 days, respectively. After incubation, the numbers of colonyforming units were calculated. For the properties of enamel analysis, other 18 bovine enamel samples (4 x 4 mm) were prepared, embedded in acrylic resin, serially polished and sliced into two halves: one of the fragments was reserved as control while the other was microwaved in 200 mL of distilled water for 3 minutes at 650 W. Hardness measurements were conducted using a Microhardness tester with a Knoop diamond. Five indentations were performed under a load of 25 gf for 05 seconds. For the resistance to demineralization analysis, the groups were submitted... (Complete abstract click electronic access below)
203

Esterilização de pontas diamantadas através da energia por microondas /

Farias, Renata Jansen de Mello. January 2003 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Alma Blásida Concepción Elizaur Benitez / Banca: Antonio Carlos Pizzolitto / Resumo: Tendo em vista a importância e necessidade de esterilização dos instrumentos cortantes rotatórios usados em odontologia, associada à indispensável agilidade nos atendimentos e, considerando ainda, a escassez de publicações atuais voltadas para este tema, julgou-se válida a preocupação em estudar a efetividade do método de esterilização através da energia por microondas em pontas diamantadas. Para tal, oitenta e uma pontas diamantadas foram contaminadas em uma suspensão bacteriana formada por bactérias pertencentes ao meio bucal (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divididas em três diferentes grupos e submetidas à irradiação por microondas em forno de microondas doméstico na potência máxima (800 W). Os grupos foram diferenciados entre si conforme o método de acondicionamento dos corpos-de-prova (2) e o procedimento para esterilização (3). No Procedimento de esterilização P1, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados em placas de Petri contendo 40 mL de água e submetidos à irradiação por microondas nos períodos de 0, 1, 2 e 3 minutos. No Procedimento de esterilização P2, os corpos-de-prova foram envolvidos em folha de poliéster, acondicionados em envelopes para esterilização e expostos à energia por microondas nos períodos de 0, 2, 4, 5 e 6 minutos, sem sofrerem previamente o procedimento de limpeza. E no Procedimento de esterilização P3, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados e submetidos à irradiação conforme o método anterior. A esterilização foi obtida tanto no Procedimento P1, no período de um minuto, quanto no Procedimento P3, no período de 6 minutos. Portanto, pudemos concluir...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Concerning the importance and the need for sterilization of the rotary cutting instruments used in dentistry, associated to the indispensable agility in the appointments and, considering also the scarceness of updated publications in regard to this theme, the preoccupation in studying the effectiveness of the sterilization method by the energy of microwaves in diamond burs was judged valid. To perform such study, eighty-one diamond burs were contaminated in a bacterial suspension formed by bacteria which belong to the oral environment (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divided in three different groups and submitted to irradiation by microwaves in a domestic microwave oven on maximum power (800 W). The groups were discriminated according to the method of packing of the specimens (2) and the procedure for sterilization (3). In the procedure for sterilization 1, the specimens were cleaned with steel sponge in water, packed in Petri dishes containing 40 mL of water and submitted to irradiation by microwaves in the periods of 0, 1, 2 and 3 minutes. In the procedure for sterilization 2, the test specimens were wrapped in a polyester sheet, packed in envelopes for sterilization and exposed to energy by microwaves in the periods of 0, 2, 4, 5 and 6 minutes, without going through the cleaning procedure previously. Finally, in the procedure for sterilization 3, the test specimens were cleaned with steel sponge in water, packed and submitted to irradiation according to the anterior method. The sterilization was obtained both in procedure 1, in the period of 1 minute, and in procedure 3, in the period of 6 minutes. Therefore, we could conclude that ...(Complete abstract, click electronic access below) / Mestre
204

Efetividade microbiológica da desinfecção por microondas e seus efeitos sobre a dureza de materiais reembasadores macios /

Pavan, Sabrina. January 2006 (has links)
Resumo: O objetivo deste estudo foi avaliar a efetividade da desinfecção utilizando energia por microondas sobre os materiais reembasadores macios Mollopast-B e Ufi Gel P contaminados com os microorganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa. Além disso, foi analisado o efeito desta técnica na dureza dos materiais reembasadores macios. Para avaliar a efetividade da desinfecção, foram confeccionados 200 corpos-de-prova de cada material sobre bases de resinas termopolimerizadas seguindo as instruções dos fabricantes. Os corpos-de-prova foram imersos meio de cultura TSB inoculados com os microrganismos C. albicans, S. aureus, B. subtilis e P. aeruginosa e submetidos à desinfecção em microondas pelos tempos de 3, 4, 5 e 6 minutos a potência de 650W. Alíquotas da suspensão resultante das diluições seriadas de 10-2-10 -5 foram semeadas em placas de petri e após 48 h de incubação o número de colônias foi calculado (ufc/mL). Para a avaliação do efeito da desinfecção com energia por microondas sobre a dureza dos materiais, 40 corpos-de-prova de cada reembasador macio foram submetidos aos diferentes tempos de desinfecção em microondas (3, 4, 5 e 6 min). As mediadas de dureza foram realizadas com um durômetro shore A em diferentes períodos: imediatamente após a confecção dos corpos, 24, 48 h e após 7 dias. Os dados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,01). Os resultados obtidos mostraram que: a - os tempos de 4, 5 e 6 minutos de irradiação com energia por microondas esterilizou os corpos-de-prova dos materiais Molloplast B e Ufi Gel P; b - 3 minutos de irradiação promoveu a desinfecção dos corpos-de-prova do material Molloplast B contaminados com B. subtilis, S. aureus e P. aeruginosa; c - a dureza apresentou maiores alterações nos tempos de desinfecção 5 e 6 min. / Abstract: The aim of this study was to evaluate the effectiveness of different times of exposure in microwave to disinfect two long-term soft lining materials (Molloplast B and Ufi Gel P) and the effects of this method on the hardness of these materials. Specimens of soft liners were made on an acrylic denture base resin and individually inoculated with C. albicans, S. aureus, B. subtilis and P. aeruginosa. After 24 hours at 37º C, 160 specimens of each material were individually submitted to microwave irradiation at 650 W for 3, 4, 5 and 6 minutes. Forty specimens were used as positive controls. Replicated specimens were plated on selective media appropriate for each microorganism. After incubation at 37ºC for 48 hours, colonies counts were quantified for each plated specimens (ufc/mL). To evaluate the effects of disinfection with microwave energy at different times of exposure on the hardness, fifty rectangular specimens (36 x 7 x 6 mm in thickness) were made for each material. Ten samples of each material were immersed in 200 mL of distilled water and disinfected in a microwave oven for 3, 4, 5 and 6 minutes at 650 W. The specimens were microwaved twice and hardness values were obtained with a Shore A durometer at different times: immediately after specimen fabrication and after 24, 48 hours and 7 days. Control specimens of each material were not disinfected and were maintained in distilled water during the role experimental period. Data were submitted to ANOVA and Tukey's test (p<0.01). The results showed that: a- sterilization was obtained at 6, 5 and 4 minutes of microwave irradiation for all specimens relined with Ufi Gel P and Molloplast B contaminated with all microorganisms; b- the specimens relined with Molloplast B contaminated with B. subtilis, S. aureus and P. aeruginosa and irradiated for 3 minutes demonstrated growth after incubation; c- the 6 minutes of microwave disinfection promoted the lower shore A hardness mean values for Molloplast. / Orientador: João Neudenir Arioli Filho / Coorientador: Denise Madalena Palomari Spolidorio / Banca: Helena de Freitas Oliveira Paranhos / Banca: Marcelo Ferraz Mesquita / Banca: Wirley Gonçalves Assunção / Banca: Francisco de Assis Mollo Junior / Doutor
205

A influência das micro-ondas na produção de biodiesel / The influence of microwaves in the production of biodiesel

Hamamoto, Marcus Vinícius 17 August 2018 (has links)
Orientador: Paulo Roberto Gardel Kurka / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-17T17:40:32Z (GMT). No. of bitstreams: 1 Hamamoto_MarcusVinicius_M.pdf: 2775538 bytes, checksum: 230c7054fbc144266d6ce53cf64b5f29 (MD5) Previous issue date: 2011 / Resumo: Com exceção da energia nuclear e da energia proveniente de hidroelétricas, a maior parte da energia consumida no mundo vem dos combustíveis fósseis, ou seja, do petróleo, do carvão mineral e do gás natural, que são recursos limitados. Os biocombustíveis são produzidos a partir de biomassa, que assim como a energia dos ventos, do sol, das marés e das águas, é considerada uma fonte renovável de energia. O biodiesel é biodegradável, renovável e obedece ao ciclo de carbono, sendo definido como mono-alquil éster de ácidos graxos derivado de fontes renováveis, como óleos vegetais e gorduras animais, obtido através de um processo de transesterificação, no qual ocorre a transformação de triglicerídeos em moléculas menores de ésteres de ácidos graxos e apresenta características físico-químicas semelhantes às do diesel fóssil. Neste trabalho foi projetada e montada uma bancada de testes com o objetivo de testar e validar um novo método de obtenção de biodiesel através da aplicação de micro-ondas durante a reação de transesterificação. Foi utilizado óleo de girassol comercial como matéria prima, álcool etílico anidro como reagente e metilato de sódio como catalisador nos testes. Ao final dos experimentos foi constatado que algumas modificações na bancada de testes levariam a resultados mais satisfatórios, porém foi possível comprovar que a utilização da energia das micro-ondas na produção de biodiesel pelo método contínuo acelera muito o processo de reação de transesterificação / Abstract: Excepting the nuclear energy and the hydropower, most of the energy consumed in the world comes from fossil fuels which mean petroleum, mineral coal and natural gas. Those are limited sources. Biofuels are produced from biomass. Biomass is a renewable source of energy like the wind, the sun and the water. Biodiesel is biodegradable, renewable and it obeys the cycle of carbon. It is defined as a blend of mono-alkyl esters of fatty acids derived from renewable sources, as vegetable oils and animal fats. It is obtained by means of a transesterification process, in which takes place the transformation of triglycerides into smaller molecules of fatty acid esters, and it displays physical and chemical characteristics similar to the ones of a fossil fuel-derived diesel oil. In this work, a test bench was designed in order to test and validate a new method of producing biodiesel by applying microwaves during the transesterification process. Sunflower oil was used as raw material, ethyl alcohol was used as a reagent and sodium methylate was used as a catalyst in the tests. As a result, it was found that a few modifications in the test bench would have given better results. It was concluded that the continuous method of production of biodiesel was quite accelerated by using the microwave energy during the process / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
206

Movimentação dental linear em protese total superior e inferior em função de diferentes tecnicas de inclusão / Linear dental movement of maxillary and mandibular complete dentures in function of enclosing techniques

Joia, Fabio Alves 19 August 2005 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T02:25:21Z (GMT). No. of bitstreams: 1 Joia_FabioAlves_M.pdf: 5977969 bytes, checksum: e66707336fade444f0c8a18dedfa11c1 (MD5) Previous issue date: 2005 / Resumo: O presente estudo avaliou a movimentação dental linear em prótese total superior e inferior em função de diferentes técnicas de inclusão. Quarenta pares do conjunto modelo-base de prova em cera, com os dentes artificiais montados, das arcadas superior e inferior, foram distribuídos ao acaso em quatro grupos de 10 pares cada, recebendo os seguintes tratamentos: Grupo A ¿ Inclusão em mufla monomaxilar de Cloreto de Polivinila (PVC) com muralha de gesso Tipo III; Grupo B ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, sem retenção nos dentes artificiais; Grupo C ¿ Inclusão em mufla de PVC bimaxilar com muralha de gesso Tipo III; Grupo D ¿ Inclusão em mufla de PVC bimaxilar com muralha de silicone para laboratório, com retenção nos dentes artificiais. Nos quatro grupos a resina acrílica utilizada na polimerização das próteses foi a resina termicamente ativada por energia de microondas, sendo o ciclo de polimerização realizado com um tempo de 20 minutos a 20% da potência, mais um ciclo de 5 minutos a 60% da potência do forno de microondas de 960 W de potência máxima, sem intervalo entre os ciclos. Sete distâncias em arco, duas distâncias diagonais e três distâncias transversais foram mensuradas, por um único avaliador, antes da inclusão e após a polimerização da base, com auxílio do microscópio mensurador linear (Olympus STM), com precisão de 0,0005 milímetro. Os dados obtidos foram submetidos à análise estatística pelo método não paramétrico de Kruskal-Wallis (p<0,05) e pelas comparações múltiplas pelo método de Dunn. A análise demonstrou diferenças estatisticamente significantes para três medidas em arco, as duas distâncias diagonais e as três distâncias transversais, entre o grupo de inclusão monomaxilar (A) e pelo menos um grupo de inclusão bimaxilar (B, C ou D), sendo os menores valores de alterações dentais lineares encontrados, em sua maioria, nos grupos de inclusão bimaxilar com muralha de silicone (B e D). Diante das condições experimentais presentes, foi possível concluir que o método de inclusão bimaxilar é mais viável quando associado ao uso da muralha de silicone com ou sem retenções nos dentes artificiais, em relação à inclusão monomaxilar / Abstract: The present study evaluated linear dental movement in maxillary and mandibular complete denture using different flasking technics. Forty pairs of the joint model-wax base, of maxillary and mandibular arches, with mounted artificial teeth, had been randomized distributed into four groups of 10 pairs each, receiving the following treatments: GA: invested in conventional flask, in a total gypsum environment; GB: invested in special flask for simultaneous polymerization using silicone and gypsum base; GC: invested in special flask for simultaneous polymerization of maxillary and mandibular prostheses in a total gypsum environment; GD: invested in special flask for simultaneous polymerization using silicone, gypsum base, and retentions on artificial teeth. The prostheses were processed with heat-polymerized acrylic resin for microwaves energy polymerization, during 20 minutes at 20% of the power, plus an additional cycle of 5 minutes at 60% of the power, of a microwave oven of 960W maximum power, without interval between the cycles. Seven arch distances, two diagonal distances and three transversal distances had been measured, by an only appraiser, before flasking and after processing, with aid of a measuring microscope (Olympus, model STM), with 0.0005 millimeter precision. Data had been statistically analyzed by Kruskal-Wallis test (p<0.05) and Dunn test. It demonstrated statistically significant differences in three arch distances, two diagonal distances and three transversal distances, between group A (conventional flask) and at least one group of bimaxilar flask (B, C or D), with the lesser values of linear dental alterations been found, in its majority, at bimaxilar flask with silicone and gypsum base groups (B and D). Ahead of the experimental conditions gifts, it was possible to conclude that bimaxilar flasking method is more viable when associate to the use of the silicone and gypsum base with or without retention in artificial teeth, when compared with conventional flasking procedure / Mestrado / Protese Dental / Mestre em Clínica Odontológica
207

Estudo da aplicação de microondas na secagem de bananas tratadas osmoticamente / Study on the application of microwaves to the drying of osmotically treated bannanas

Pereira, Nadia Rosa 27 April 2007 (has links)
Orientador: Antonio Marsaioli Junior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-08T14:52:00Z (GMT). No. of bitstreams: 1 Pereira_NadiaRosa_D.pdf: 2441787 bytes, checksum: 905d577c0be232df49ad4362e6f6452b (MD5) Previous issue date: 2007 / Doutorado / Doutor em Engenharia de Alimentos
208

Coagulação por microondas versus escleroterapia apos ligadura elastica endoscopica para tratamento de varizes esofagicas em cirroticos. / Microwave coagulation versus sclerotherapy after band ligation for treatment of esophageal varices in cirrhotic

Monici, Leonardo Trevizan 08 September 2007 (has links)
Orientador: Elza Cotrim Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T15:18:59Z (GMT). No. of bitstreams: 1 Monici_LeonardoTrevizan_M.pdf: 992979 bytes, checksum: 421e46aba044c21d7aac0098bd50c43b (MD5) Previous issue date: 2007 / Resumo: Antecedentes: A ligadura elástica endoscópica (LE) é um dos métodos mais utilizados para profilaxia secundária de sangramento por varizes esofágicas, mas a recorrência varicosa é freqüente após este tratamento. A associação de LE com escleroterapia endoscópica por injeção (EI) reduz este risco. A coagulação por microondas (MC) é um método térmico de terapia endoscópica e sua associação com LE poderia reduzir o risco de recidiva de varizes. Objetivo: Avaliar a segurança e a eficácia da associação de LE com MC para o tratamento e prevenção da recidiva de varizes esofágicas em pacientes cirróticos com antecedente de hemorragia por varizes, em comparação com a associação de LE com EI. Desenho: Estudo prospectivo randomizado e controlado. Pacientes: Setenta pacientes cirróticos com episódio prévio de sangramento por varizes esofágicas tratados com LE até que restassem apenas vasos de fino calibre. Métodos: Trinta e seis pacientes foram randomizados para receber EI com etanol absoluto (Grupo A) e trinta e quatro para receber MC (Grupo B) até a completa erradicação das varizes. Foi realizado seguimento endoscópico para detecção de recidiva. Principais parâmetros avaliados: Ressangramento, complicações das intervenções, mortalidade dos pacientes, recorrência de varizes e fatores que afetam a recidiva. Resultados: Não houve diferença significativa entre os grupos A e B em termos de recidiva de varizes (27,7% versus 17,6%), ressangramento (8,3% versus 0%) e mortalidade em um tempo médio de seguimento de 34,9 ± 11,4 meses. As complicações foram raras e nenhuma diferença significativa foi verificada entre os grupos. A presença de varizes gástricas afetou a recorrência de varizes com um risco relativo de 3,9 vezes (IC de 1,14 a 13,1). Conclusões: A aplicação de MC no esôfago após a LE é segura e eficaz no tratamento de varizes esofágicas. Não houve diferença nas taxas de recorrência comparando-se a associação de LE com MC em relação à LE com EI. A presença de varizes gástricas aumenta o risco de recidiva / Abstract: Background: Endoscopic band ligation (LE) is an usual choice for secondary prophylaxis of esophageal variceal bleeding but recurrence of varices is frequent after this treatment. Association of EBL with endoscopic injection sclerotherapy (EI) reduces this risk. Microwave coagulation (MC) is a thermal endoscopic therapy method and its association with EBL may reduce the risk of variceal recurrence. Objective: Evaluate the safety and efficacy of the association of LE with MC for treatment and prevention of recurrence of esophageal varices compared to the association of LE with EI. Design: Randomized controlled trial. Patients: Seventy cirrhotic patients with previous bleeding from esophageal varices treated with EBL until only thin vessels remained. Interventions: Thirty-six patients were randomized to receive EI with ethanol (Group A) and thirty-four to receive MC (Group B) until complete eradication. Endoscopic follow-up was performed to detect recurrence. Main outcome measurements: Rebleeding, intervention complications, mortality, variceal recurrence and factors that affect recurrence. Results: No significant difference was found between Groups A and B in variceal recurrence (27.7% vs. 17.6%), rebleeding (8.3% vs. 0%) and mortality in a mean follow-up of 34.9 ± 11.4 months. Complications were rare and no difference was observed between both groups. The presence of gastric varices affects recurrence with an odds ratio of 3.9 (1.14 to 13.1). Conclusions: Application of MC in the esophagus after band ligation is safe and effective. There is no difference in recurrence rates comparing the association of LE with MC to LE plus EI. The presence of gastric varices increases the risk of esophageal varices recurrence / Mestrado / Clinica Medica / Mestre em Clinica Medica
209

Estudo, otimização e aplicação de microondas acoplado ao processo oxidativo avançado H2O2/UV na degradação da tartrazina / Study, optimization, and application of microwaves coupled to the H2O2/UV advanced oxidation process in the degradation of tartrazine

Fernanda Parolin 11 August 2011 (has links)
Os corantes azo são amplamente utilizados em muitas indústrias, entre elas as alimentícias, farmacêuticas e têxteis. Quando essas moléculas estão presentes no efluente industrial tornam o seu tratamento, que na maioria dos casos é biológico, difícil. Suas complexas estruturas são altamente estáveis e a presença de grupos sulfônicos (-SO3H) torna o corante ácido e altamente solúvel em água. Um exemplo deste tipo de corante é a tartrazina que pode causar efeitos adversos para a saúde humana, como alergia. Desde o início dos anos 70, quando os Processos Oxidativos Avançados (POAs) foram reconhecidos por sua capacidade de degradar poluentes em meio aquoso, houve um aumento significativo nas pesquisas por duas razões: a diversidade de tecnologias envolvidas e a grande variedade de efluentes que os POAs são capazes de tratar. A fotoquímica assistida por microondas (MO) consiste na combinação de dois tipos distintos de radiação eletromagnética, microondas e UV/VIS, na ativação de reações químicas. Frequentemente está associada ao uso de uma lâmpada de descarga sem eletrodo (LDE) que gera radiação ultravioleta (UV) sob a influência de um campo de microondas. O presente trabalho tem como objetivo tratar uma solução de tartrazina (25 mg L-1) utilizando o processo H2O2/UV/MO e otimizando-o a fim de se obter a maior degradação com a utilização da menor quantidade de oxidante possível. Para tanto, elaborou-se um planejamento fatorial com a finalidade de observar o comportamento das variáveis independentes pH e concentração inicial de peróxido de hidrogênio no processo. A partir dos resultados, elaborou-se um planejamento composto central a fim de se ajustar um modelo polinomial aos dados obtidos. A condição ótima de tratamento para as variáveis independentes foi: pH = 2,6 e [H2O2] = 2 &times; 10-3 mol L-1. A variável-resposta observada foi a remoção de cor (por meio da integração da área dos espectros na região do visível). A cinética obtida para o processo H2O2/UV/MO foi de ordem zero, com k = 3,9 &times; 10-2 u.a.-1 min-1 e, aproximadamente, 92% de descoramento em 24 minutos. A biodegradabilidade (DBO5/DQO) e a análise de carbono orgânico total (COT) não apresentaram variação significativa. No entanto, pôde-se observar, através da CE50, que o processo H2O2/UV/MO reduziu a fitotoxicidade da solução de tartrazina, indicando a possível formação de intermediários de degradação menos tóxicos que a molécula original. A avaliação do efeito das microondas foi feita pelo estudo da degradação da solução de tartrazina através dos processos H2O2, MO, H2O2/MO e UV/MO, sendo que o descoramento não passou de 20%, indicando que as MO influenciam no processo H2O2/UV devido ao possível sinergismo com a radiação UV e também pelos possíveis efeitos térmicos e não térmicos exercidos por essa radiação. / Azo dyes are extensively used in many industries such as food, drugs, and textiles ones. When these molecules are present in the industrial wastewaters, they make their treatment, which is in most cases a biological one, quite difficult. Their complex structures are very stable and the presence of sulfonic groups (-SO3H) makes the azo dyes acid and highly water-soluble. Tartrazine is an example of these dyes and can cause adverse effects to human health, like allergy. Since the early 70\'s, when Advanced Oxidation Processes (AOPs) were recognized by their capacity of degrading pollutants in aqueous media, there was a significant increase in research and for two reasons: the diversity of technologies involved and the many kinds of wastewaters that AOP can treat. The microwave-assisted photochemistry is the combination of two distinct types of electromagnetic radiations: microwave (MW) and UV/VIS. It is often associated with the use of an electrodeless discharge lamp (EDL), which generates ultraviolet (UV) radiation when placed in a microwave field. The aim of the present work is to treat a solution of tartrazine (25 mg L-1) by the H2O2/UV/MW process, as well as optimizing the process in order to obtain degradation with the use of the lowest possible amount of oxidant. For that purpose, a factorial design was performed to observe the effect of the independent variables pH and hydrogen peroxide concentration. With the results obtained, a composite central design was performed to fit a polynomial model to the data. The optimum treatment condition was: pH = 2.6 and [H2O2] = 2 &times; 10-3 mol L-1. The response variable was color removal (measured by the area under the spectra obtained in the visible region). The decolorization kinetics of the H2O2/UV/MW process followed a zero order model, with k = 3,9 &times; 10-2 u.a.-1 min-1 and color removal achieved 92% in 24 minutes. The biodegradability (BOD5/COD) ratio and total organic carbon (TOC) analyses showed no significant changes. However, through the CE50 maybe observed that the H2O2/UV/MW process reduced the toxicity of the tartrazine solution, indicating the possible formation of less toxic intermediates than the original molecule. The microwaves effect was assessed in a degradation study of the tartrazine solution by H2O2, MW, H2O2/MW, and UV/MW processes, and the decolorization did not exceed 20%, indicating that the MW influence the H2O2/UV process because of the possible synergism with the UV radiation and thermal and non-thermal effects exerted by the radiation.
210

Contribuição ao estudo da redução carbotérmica de minério de ferro empregando energia de micro-ondas. / Contribution to the study of reduction carbothermic iron ore using microwave energy.

Edmilson Renato de Castro 21 October 2016 (has links)
Com a proposta de selecionar a melhor conformação de um forno para redução carbotérmica com micro-ondas, dois tipos de cavidades com formatos paralepipédico e hexagonal foram projetadas e construídas. Os dois com uma característica em comum, o pleno controle da potência fornecida e da medida da energia de micro-ondas efetivamente aplicada à carga em processo de redução podendo assim realizar balanços de energia e determinação de taxa de reação com altos níveis de confiança. Eles permitem, sobretudo, a medida simultânea de temperatura e de massa do material sob redução, e a fácil reprodutibilidade das condições de ensaio. Os fornos paralepipédico e hexagonal operam com geradores de micro-ondas de 2,45 GHz e potência ajustável até 6 kW. Durante os ensaios as amostras foram mantidas sob atmosfera de argônio. Nos testes operacionais dos fornos procedeu-se à redução carbotérmica de minério de ferro de Carajás, utilizando carvão mineral Chipanga como redutor através de pelotas auto redutoras. Obtiveram-se curvas cinéticas de redução de minério de ferro, temperatura e de consumo de energia durante o processo. Os dados colhidos com estes fornos permitiram realizar análises estatísticas da eficiência de cada tipo de forno através da taxa de reação obtida além da energia de micro-ondas efetivamente consumida na redução do minério. Ainda, foi construído um forno cilíndrico, portanto extrapolando o formato hexagonal, com potência de 15 kW, com o objetivo de averiguar como o conjunto pelotas/cavidade se comporta em condições mais drásticas. / This work deals with two different types of microwave cavities to be used in carbothermic reduction that were designed and built in order to select a better furnace conformation. Parallepipedic and hexagonal shapes were used for this purpose. Both of them share some common characteristics: full control of the power supplied to the furnace, and measurement of the effective microwave power applied to the load under reduction process. These characteristics help to achieve energy balance and reaction rate with high confidence levels. Simultaneous measurements of mass and temperature versus time are also easily done and helps reproduction of each test condition. The parallelepiped and hexagonal ovens are excited by 2.45 GHz microwave generators with adjustable power up to 6 kW. Argon gas atmosphere was used when processing the samples. Operational tests of the carbothermic reduction of iron ore from Carajás were done by the use of self-reducing pellets of Chipanga coal. Temperature and other data collected during the processes allowed calculation of their kinetic curves and energy consumption. The efficiency of each kind of furnace was obtained from statistical analysis of the data using reaction rate as well as the microwave energy consumption. Finally, going further from the hexagonal shape, a cylindrical furnace was built in order to verify the behavior of the pellets/cavity groups in heavier conditions with applied power up to 15 kW.

Page generated in 0.048 seconds