• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 14
  • 10
  • 1
  • 1
  • 1
  • Tagged with
  • 55
  • 55
  • 39
  • 25
  • 21
  • 16
  • 11
  • 11
  • 11
  • 11
  • 6
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Přínos miniinvazivní MIS-AL techniky při implantaci totální náhrady kyčelního kloubu, zdravotně sociální aspekty MIS-AL přístupu / Contribution of Minimally Invasive Total Hip Replacement - MIS-AL, Health and Social Aspects of MIS-AL Approach

MUSIL, David January 2011 (has links)
I want to present a prospective evaluation of one-year results in patients undergoing total hip arthroplasty from a minimally invasive antero-lateral approach (THA MIS-AL). And I want also to compare, by means of biochemical markers, the operative invasiveness of standard total hip replacement with that of the minimally invasive anterolateral (MIS-AL) approach.At one year after surgery we evaluated the quality of life by 60 patients using SF-36 questionaire and we compared the results with standard anterolateral approach and regional standard.
52

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 13 February 2012 (has links) (PDF)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.
53

Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe

Rahn, Helene 12 December 2011 (has links)
Im Rahmen der vorliegenden Dissertationsschrift „Semi-quantitative röntgentomographische Untersuchungen zur Biodistribution von magnetischen Nanopartikeln in biologischem Gewebe“ wurden tomographische Untersuchungen an biologischen Objekten durchgeführt. Bei diesen Objekten handelt es sich um Gewebeproben nach minimal-invasiven Krebstherapien wie zum Beispiel magnetischem Drug Targeting und magnetischer Wärmebehandlung. Der Erfolg dieser Therapien ist sowohl abhängig von der korrekten Verteilung der magnetischen Nanopartikel als auch von der Tatsache, dass diese in der Zielregion in einer ausreichenden Menge vorhanden sind. Das Vorliegen dieser beiden Voraussetzungen ist in der vorliegenden Arbeit untersucht worden. Dabei lag der Schwerpunkt der Arbeit auf der Quantifizierung von magnetischem Material in unterschiedlichen biologischen Gewebeproben mittels Röntgenmikrocomputertomographie (XµCT). Für diesen Zweck wurde ein Kalibrationssystem mit speziellen Phantomen entwickelt, mit dessen Hilfe eine Nanopartikelkonzentration einem Grauwert voxelweise zugewiesen werden kann. Mit Hilfe der Kalibration kann der Nanopartikelgehalt sowohl in monochromatischen als auch in polychromatischen tomographischen Daten im Vergleich zu magnetorelaxometrischen Ergebnissen mit wenigen Prozent Abweichung ermittelt werden. Trotz Polychromasie und damit einhergehenden Artefakten können 3-dimensionale röntgentomographische Datensätze mit einer geringfügigen Konzentrationsabweichung im Vergleich zur quantitativen Messmethode Magnetorelaxometrie semi-quantitativ ausgewertet werden. / The success of the minimal invasive cancer therapies, called magnetic drug targeting and magnetic heating treatment, depends strongly on the correct distribution of the magnetic nanoparticles on one side. On the other side it depends on the fact that a sufficient amount of magnetic nanoparticles carrying drugs is accumulated in the target region. To study whether these two requirements are fulfilled motivates this PhD thesis „Semi-quantitative X-ray-tomography examinations of biodistribution of magnetic nanoparticles in biological tissues“. The analysis of the distribution of the magnetic nanoparticles in tumours and other tissue examples is realized by means of X-ray-micro computer tomography (XμCT). The work focuses on the quantification of the magnetic nanoparticles in different biological tissue samples by means of XµCT. A calibration of the tomographic devices with adequate phantoms, developed in the frame of this work, opens now the possibility to analyze tomographic data in a semi-quantitative manner. Thus, the nanoparticle concentration can be allocated voxel-wise to the grey values of the three-dimensional tomographic data. With the help of calibration of the tomography equipments used, polychromatic as well as monochromatic three-dimensional representations of objects can be analyzed with regard to the biodistribution of magnetic nanoparticles as well as with regard to their quantity. The semi-quantitative results have been compared with results obtained with a quantitative measurement method magnetorelaxometry (MRX). Thereby a good agreement of the semi-quantitative and quantitative data has been figured out.
54

Bestimmung von Materialparametern der elastisch-plastischen Verformung und des spröden Versagens aus Small-Punch-Kleinstproben

Rasche, Stefan 01 July 2013 (has links) (PDF)
Der Small-Punch-Test (SPT) ist eine vielversprechende minimalinvasive mechanische Prüfmethode, wenn nur sehr wenig Material für Proben zur Verfügung steht. Die vorliegende Arbeit hat das Ziel, aus Small-Punch-Kleinstproben wahre Materialparameter der elastisch-plastischen Verformung und des spröden Versagens zu bestimmen. Die Kraft-Verschiebungs-Kurve des Versuchs stellt die nichtlineare Materialantwort der inhomogen beanspruchten Probe dar. Das inverse Problem der Identifikation konstitutiver Materialparameter wird numerisch mit Hilfe von Finite-Elemente-Simulationen in Verbindung mit einem Response-Surface-Modell und nichtlinearer Optimierungsverfahren gelöst, indem die Abweichung zwischen gemessener und simulierter Kurve minimiert wird. Mit Hilfe einer eigens entwickelten Kühlapparatur wurden Versuche mit ferritischen Stählen von Raumtemperatur bis hinunter zu -191°C durchgeführt und die temperaturabhängigen Fließkurven identifiziert. Bei tiefen Temperaturen wurden die Weibull-Parameter der zufällig streuenden Sprödbruchfestigkeit bestimmt und die Bruchzähigkeitsverteilung durch Simulation einer CT-Probe vorhergesagt. Für eine Aluminiumoxidkeramik wurden ebenfalls die Weibull-Parameter bestimmt sowie mit Indenterrissen versehene Proben zur Abschätzung der Bruchzähigkeit verwendet. / The small punch test (SPT) is a promising minimally invasive material testing method, especially in cases where only small amounts of material are available. This thesis is aimed at identifying true material parameters of elastic-plastic deformation and brittle fracture. The load-displacement curve of the test represents the non-linear material response of the nonuniformly stressed specimen. The identification of material parameters of constitutive laws is an inverse problem, which is solved numerically. Finite element simulations together with a response surface model and nonlinear optimization techniques are applied to minimize the error between measured and simulated curves. A specially developed cooling apparatus was used to perform tests with ferritic steels from room temperature down to -191°C. The temperature dependent yield stresses and hardening curves were identified. At low temperatures the Weibull parameters of randomly distributed cleavage fracture strength were estimated. The fracture toughness distribution was then predicted by the help of a finite element simulation of a CT specimen. Furthermore the Weibull parameters of an alumina ceramic were determined and its fracture toughness was predicted using specimens prepared with indentation cracks.
55

Bestimmung von Materialparametern der elastisch-plastischen Verformung und des spröden Versagens aus Small-Punch-Kleinstproben

Rasche, Stefan 29 April 2013 (has links)
Der Small-Punch-Test (SPT) ist eine vielversprechende minimalinvasive mechanische Prüfmethode, wenn nur sehr wenig Material für Proben zur Verfügung steht. Die vorliegende Arbeit hat das Ziel, aus Small-Punch-Kleinstproben wahre Materialparameter der elastisch-plastischen Verformung und des spröden Versagens zu bestimmen. Die Kraft-Verschiebungs-Kurve des Versuchs stellt die nichtlineare Materialantwort der inhomogen beanspruchten Probe dar. Das inverse Problem der Identifikation konstitutiver Materialparameter wird numerisch mit Hilfe von Finite-Elemente-Simulationen in Verbindung mit einem Response-Surface-Modell und nichtlinearer Optimierungsverfahren gelöst, indem die Abweichung zwischen gemessener und simulierter Kurve minimiert wird. Mit Hilfe einer eigens entwickelten Kühlapparatur wurden Versuche mit ferritischen Stählen von Raumtemperatur bis hinunter zu -191°C durchgeführt und die temperaturabhängigen Fließkurven identifiziert. Bei tiefen Temperaturen wurden die Weibull-Parameter der zufällig streuenden Sprödbruchfestigkeit bestimmt und die Bruchzähigkeitsverteilung durch Simulation einer CT-Probe vorhergesagt. Für eine Aluminiumoxidkeramik wurden ebenfalls die Weibull-Parameter bestimmt sowie mit Indenterrissen versehene Proben zur Abschätzung der Bruchzähigkeit verwendet. / The small punch test (SPT) is a promising minimally invasive material testing method, especially in cases where only small amounts of material are available. This thesis is aimed at identifying true material parameters of elastic-plastic deformation and brittle fracture. The load-displacement curve of the test represents the non-linear material response of the nonuniformly stressed specimen. The identification of material parameters of constitutive laws is an inverse problem, which is solved numerically. Finite element simulations together with a response surface model and nonlinear optimization techniques are applied to minimize the error between measured and simulated curves. A specially developed cooling apparatus was used to perform tests with ferritic steels from room temperature down to -191°C. The temperature dependent yield stresses and hardening curves were identified. At low temperatures the Weibull parameters of randomly distributed cleavage fracture strength were estimated. The fracture toughness distribution was then predicted by the help of a finite element simulation of a CT specimen. Furthermore the Weibull parameters of an alumina ceramic were determined and its fracture toughness was predicted using specimens prepared with indentation cracks.

Page generated in 0.0891 seconds