• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 23
  • 23
  • 23
  • 23
  • 9
  • 8
  • 8
  • 8
  • 8
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo comparativo de matrizes dérmicas de colágeno bovino com e sem lâmina de silicone no tratamento da contratura cicatricial pós-queimadura - Análise clínica e histológica / Comparative study of dermal regeneration template made by bovine collagen with and without silicone layer in the treatment of post-burn contracture: clinical and histological analysis

Vana, Luiz Philipe Molina 09 August 2017 (has links)
O surgimento das matrizes de regeneração dérmica nas duas últimas décadas permitiu um grande avanço no tratamento tanto das queimaduras agudas como das sequelas. No entanto, ainda há carência de informações sobre a relação entre os resultados clínicos e o que ocorre no tecido com cada tipo de matriz. O objetivo deste estudo foi avaliar prospectivamente os aspectos clínicos quanto à qualidade de pele, escala de Vancouver e POSAS, função e retração da área tratada e os aspectos histológicos na microscopia de luz e eletrônica, com o uso de duas matrizes de regeneração dérmica, ambas de colágeno bovino, uma de duas camadas, recoberta com lâmina de silicone e outra sem. Vinte e quatro pacientes, sorteados 12 em cada grupo, tiveram suas retrações cicatriciais secundárias à queimaduras tratadas em duas cirurgias, a primeira de liberação da retração e colocação da matriz e a segunda, colocação do auto enxerto de pele; em ambas as cirurgias foi utilizado o curativo de pressão negativa. As avaliações da escala de Vancouver e medidas da retração da área foram realizadas no pré-operatório, 1, 3, 6 e 12 meses e a escala de POSAS e avaliação funcional no pré-operatório e aos 12 meses. As biópsias foram colhidas no pré-operatório, no dia da colocação do enxerto de pele, 12 dias, 2, 6 e 12 meses após o enxerto. A avaliação clínica mostrou retração de todas as áreas tratadas, melhora da qualidade da pele e funcional em todos os pacientes. A matriz com silicone, mostrou superioridade dos resultados quanto a qualidade da pele, função e menor retração da área tratada. A análise histológica mostrou o crescimento de tecido conjuntivo denso idêntico ao tecido cicatricial original, sem diferenças entre as matrizes e que não se assemelha à derme normal. Também não foi observada diferença no diâmetro das fibrilas de colágeno do tecido neoformado, a pele normal e a cicatriz / The advent of dermal regenerate templates has fostered major advances in the treatment of acute burns and their sequelae, in the last two decades. Both data on morphological aspects of the newly-formed tissue, and clinical trials comparing different templates, are still lacking. The goal of this study was to prospectively analyze the outcome of patients treated with two of the existing templates, followed by thin skin autograft. They are both made of bovine collagen, one includes a superficial silicone layer. Surgery was performed on patients with impaired mobility resulting from burn sequelae (n = 12 per template). Negative pressure therapy was applied post-surgically; patients were monitored for 12 months. Data on scar skin quality (Vancouver and POSAS evaluation scales), rate of joint mobility recovery, and graft contraction were recorded; as well as morphological analyses at light microscopical and ultrastructural levels. Improvement in mobility and skin quality were demonstrated along with graft contraction, in all patients. The silicone-coupled template showed the best performance in all aspects. There was sub epidermal growth of dense connective tissue, indistinguishable from the original scars in both templates. The formation of tissue resembling normal dermis was not detected in any of the cases. Likewise, the ultrastructural analysis showed the same architecture of the connective tissue among the template scars and the original scar. No difference was detected when the collagen fibril diameters of the normal skin and of the scars (original and of the two templates) were compared
12

Estudo comparativo de matrizes dérmicas de colágeno bovino com e sem lâmina de silicone no tratamento da contratura cicatricial pós-queimadura - Análise clínica e histológica / Comparative study of dermal regeneration template made by bovine collagen with and without silicone layer in the treatment of post-burn contracture: clinical and histological analysis

Luiz Philipe Molina Vana 09 August 2017 (has links)
O surgimento das matrizes de regeneração dérmica nas duas últimas décadas permitiu um grande avanço no tratamento tanto das queimaduras agudas como das sequelas. No entanto, ainda há carência de informações sobre a relação entre os resultados clínicos e o que ocorre no tecido com cada tipo de matriz. O objetivo deste estudo foi avaliar prospectivamente os aspectos clínicos quanto à qualidade de pele, escala de Vancouver e POSAS, função e retração da área tratada e os aspectos histológicos na microscopia de luz e eletrônica, com o uso de duas matrizes de regeneração dérmica, ambas de colágeno bovino, uma de duas camadas, recoberta com lâmina de silicone e outra sem. Vinte e quatro pacientes, sorteados 12 em cada grupo, tiveram suas retrações cicatriciais secundárias à queimaduras tratadas em duas cirurgias, a primeira de liberação da retração e colocação da matriz e a segunda, colocação do auto enxerto de pele; em ambas as cirurgias foi utilizado o curativo de pressão negativa. As avaliações da escala de Vancouver e medidas da retração da área foram realizadas no pré-operatório, 1, 3, 6 e 12 meses e a escala de POSAS e avaliação funcional no pré-operatório e aos 12 meses. As biópsias foram colhidas no pré-operatório, no dia da colocação do enxerto de pele, 12 dias, 2, 6 e 12 meses após o enxerto. A avaliação clínica mostrou retração de todas as áreas tratadas, melhora da qualidade da pele e funcional em todos os pacientes. A matriz com silicone, mostrou superioridade dos resultados quanto a qualidade da pele, função e menor retração da área tratada. A análise histológica mostrou o crescimento de tecido conjuntivo denso idêntico ao tecido cicatricial original, sem diferenças entre as matrizes e que não se assemelha à derme normal. Também não foi observada diferença no diâmetro das fibrilas de colágeno do tecido neoformado, a pele normal e a cicatriz / The advent of dermal regenerate templates has fostered major advances in the treatment of acute burns and their sequelae, in the last two decades. Both data on morphological aspects of the newly-formed tissue, and clinical trials comparing different templates, are still lacking. The goal of this study was to prospectively analyze the outcome of patients treated with two of the existing templates, followed by thin skin autograft. They are both made of bovine collagen, one includes a superficial silicone layer. Surgery was performed on patients with impaired mobility resulting from burn sequelae (n = 12 per template). Negative pressure therapy was applied post-surgically; patients were monitored for 12 months. Data on scar skin quality (Vancouver and POSAS evaluation scales), rate of joint mobility recovery, and graft contraction were recorded; as well as morphological analyses at light microscopical and ultrastructural levels. Improvement in mobility and skin quality were demonstrated along with graft contraction, in all patients. The silicone-coupled template showed the best performance in all aspects. There was sub epidermal growth of dense connective tissue, indistinguishable from the original scars in both templates. The formation of tissue resembling normal dermis was not detected in any of the cases. Likewise, the ultrastructural analysis showed the same architecture of the connective tissue among the template scars and the original scar. No difference was detected when the collagen fibril diameters of the normal skin and of the scars (original and of the two templates) were compared
13

V.A.C.<sup>®</sup> Therapy in the Management of Paediatric Wounds: Clinical Review and Experience

Baharestani, Mona, Amjad, Ibrahim, Bookout, Kim, Fleck, Tatjana, Gabriel, Allen, Kaufman, David, McCord, Shannon Stone, Moores, Donald C., Olutoye, Oluyinka O., Salazar, Jorge D., Song, David H., Teich, Steven, Gupta, Subhas 01 August 2009 (has links)
Baharestani M, Amjad I, Bookout K, Fleck T, Gabriel A, Kaufman D, McCord SS, Moores DC, Olutoye OO, Salazar JD, Song DH, Teich S, Gupta S. V.A.C. ® Therapy in the management of paediatric wounds: clinical review and experience. ABSTRACT Usage of negative pressure wound therapy (NPWT) in the management of acute and chronic wounds has grown exponentially in the past decade. Hundreds of studies have been published regarding outcomes and methods of therapy used for adult wounds. This treatment is increasingly being used to manage difficult-to-treat paediatric wounds arising from congenital defects, trauma, infection, tumour, burns, pressure ulceration and postsurgical complications in children, although relatively few studies have been aimed at this population. Given the anatomical and physiological differences between adults and children, a multidisciplinary expert advisory panel was convened to determine appropriate use of NPWT with reticulated open cell foam (NPWT/ROCF) as delivered by Vacuum Assisted Closure® (V.A.C.® Therapy, KCI Licensing, Inc., San Antonio, TX) for the treatment of paediatric wounds. The primary objectives of the expert advisory panel were to exchange state-of-practice information on paediatric wound care, review the published data regarding the use of NPWT/ROCF in paediatric wounds, evaluate the strength of the existing data and establish guidelines on best practices with NPWT/ROCF for the paediatric population. The proposed paediatrics-specific clinical practice guidelines are meant to provide practitioners an evidence base from which decisions could be made regarding the safe and efficacious selection of pressure settings, foam type, dressing change frequency and use of interposing contact layer selections. The guidelines reflect the state of knowledge on effective and appropriate wound care at the time of publication. They are the result of consensus reached by expert advisory panel members based on their individual clinical and published experiences related to the use of NPWT/ROCF in treating paediatric wounds. Best practices are described herein for novice and advanced users of NPWT/ROCF. Recommendations by the expert panel may not be appropriate for use in all circumstances. Decisions to adopt any particular recommendation must be made by the collaborating medical team, including the surgeon and wound care specialist based on available resources, individual patient circumstances and experience with the V.A.C.® Therapy System.
14

Estudo comparativo entre o método USP de terapia por pressão negativa e o sistema V.A.C® no tratamento de feridas traumáticas / A low-cost negative pressure wound therapy versus a widely commercially available therapy for the treatment of complex traumatic injuries: a prospective, randomized, non-inferiority trial

Kamamoto, Fábio 01 February 2017 (has links)
A terapia de tratamento de feridas por pressão negativa (TPN) não é nova. Ela foi aprovada nos Estados Unidos da América em 1996 e, desde então, tem sido amplamente utilizada em uma grande variedade de ferimentos. Ela tem aplicação no tratamento de feridas agudas e crônicas, e trouxe conforto para pacientes, cuidadores e profissionais da área da Saúde. Uma das indicações desta terapia é no tratamento de feridas decorrentes de trauma. Ela pode ser utilizada como uma \"ponte\" entre o surgimento da lesão inicial e a cirurgia de fechamento definitivo da ferida, naqueles casos em que o fechamento primário não é possível. O grande obstáculo para democratização desse procedimento é o custo. Ele se mantém alto, principalmente nos pacientes que necessitam de um uso prolongado do método. Na tentativa de contornar esse problema, o Hospital Universitário da USP desenvolveu em 2007 uma TPN de baixo custo baseada em uma válvula estabilizadora de pressão (Curavac VX 200®, Ventrix Health Innovation, Brasil) conectada à fonte de vácuo da parede do hospital e a uma cobertura de ferida com gaze estéril selada por filme plástico adesivo. Este estudo comparou essa terapia de baixo custo (grupo USP) com a terapia padrão no Mercado (VAC system®, KCI, San Antonio - Texas) - Grupo VAC em um desenho prospectivo, randomizado, no formato de não inferioridade. Ou seja, o objetivo primário era verificar se o tempo necessário para a ferida estar apta para cirurgia de fechamento definitivo era equivalente nos dois métodos propostos. Foram estudadas, também, a velocidade de crescimento do tecido de granulação e as mudanças na área da ferida, além do custo de cada tratamento. Em relação ao tempo necessário para ferida estar apta para a cirurgia de retalho, o Grupo USP apresentou um resultado de 9,6±4,5 dias. O Grupo VAC apresentou 12,8±8,6 dias. A diferença não foi estatisticamente significante (p=0,379). Em relação ao aumento de tecido de granulação por dia de tratamento, os dois métodos apresentaram resultados semelhantes: USP= 5,79 ± 2,93% e VAC 5,06 ± 5,15% (p=0,408). Em relação à variação de área, os dois grupos apresentaram um aumento: USP 1,13 ±0,80% e VAC 1,12 ± 0,80% (p=0,934). Foi observada uma importante diferença entre os custos do tratamento. O tratamento no Grupo USP custou, em média, R$ 47,89; enquanto o tratamento no grupo VAC, R$ 2.757,40. Conclusão: A terapia USP de tratamento de feridas por pressão negativa não é inferior à terapia VAC system® no tratamento de feridas complexas de origem traumática / Negative Pressure Wound Therapy (NPWT) was approved by the FDA in 1996 and since then has become widely adopted for a broad range of wounds. NPWT has many indications, both acute and chronic, and has brought great comfort to patients, caregivers, doctors, and nurses. Some authors suggest that NPWT may be used in traumatic wounds when primary closure is not possible after or in between debridements as a bridge to definitive closure. The big real obstacle to this useful procedure is the cost, which remains expensive for prolonged indications, making it unaffordable where these dressings are needed. In 2007 the University of São Paulo developed a low-cost NPWT based in a pressure stabilizer device (Curavac VX 200®, Ventrix Health Innovation, Brazil) connected to the hospital wall-vacuum and a gauzed-sealed dressing. No randomised trial has compared USP Negative Pressure Wound Therapy with the commercial vacuum assisted closure device (VAC system®). Our choice of a non-inferiority trial was based on the expectation that the time necessary for the improvement of the wound bed for patients treated with the USP therapy was no worse than the improvement time for VAC System (primary outcome). The wound bed area variation and granulation tissue growth were also assessed as secondary outcomes. In relation to the time (measured in days) necessary for the wound bed to became ready for the flap surgery, the USP group presented 9,6 ± 4,5 days. The VAC group presented 12,8 ± 8,6 days. The difference was not statistical significant (p=0,379). In relation to granulation tissue increase the two methods of NPWT (USP and VAC) presented very similar results: USP= 5,79( ± 2,93) and VAC 5,06 ( ± 5,15) (p=0,408). Regarding to wound area the both groups presented an increase: USP 1,13 ± 0,80 and VAC 1,12( ± 0,80) p=0,934. We observed an important difference in relation to treatment costs. The USP group treatment cost is about 2% compared with VAC group. Mean Treatment Cost: USP= US$ 15,15; VAC= US$ 872,59. Conclusion: The USP Negative Pressure Wound Therapy was non-inferior to VAC System for the treatment of complex traumatic injuries
15

Estudo comparativo entre o método USP de terapia por pressão negativa e o sistema V.A.C® no tratamento de feridas traumáticas / A low-cost negative pressure wound therapy versus a widely commercially available therapy for the treatment of complex traumatic injuries: a prospective, randomized, non-inferiority trial

Fábio Kamamoto 01 February 2017 (has links)
A terapia de tratamento de feridas por pressão negativa (TPN) não é nova. Ela foi aprovada nos Estados Unidos da América em 1996 e, desde então, tem sido amplamente utilizada em uma grande variedade de ferimentos. Ela tem aplicação no tratamento de feridas agudas e crônicas, e trouxe conforto para pacientes, cuidadores e profissionais da área da Saúde. Uma das indicações desta terapia é no tratamento de feridas decorrentes de trauma. Ela pode ser utilizada como uma \"ponte\" entre o surgimento da lesão inicial e a cirurgia de fechamento definitivo da ferida, naqueles casos em que o fechamento primário não é possível. O grande obstáculo para democratização desse procedimento é o custo. Ele se mantém alto, principalmente nos pacientes que necessitam de um uso prolongado do método. Na tentativa de contornar esse problema, o Hospital Universitário da USP desenvolveu em 2007 uma TPN de baixo custo baseada em uma válvula estabilizadora de pressão (Curavac VX 200®, Ventrix Health Innovation, Brasil) conectada à fonte de vácuo da parede do hospital e a uma cobertura de ferida com gaze estéril selada por filme plástico adesivo. Este estudo comparou essa terapia de baixo custo (grupo USP) com a terapia padrão no Mercado (VAC system®, KCI, San Antonio - Texas) - Grupo VAC em um desenho prospectivo, randomizado, no formato de não inferioridade. Ou seja, o objetivo primário era verificar se o tempo necessário para a ferida estar apta para cirurgia de fechamento definitivo era equivalente nos dois métodos propostos. Foram estudadas, também, a velocidade de crescimento do tecido de granulação e as mudanças na área da ferida, além do custo de cada tratamento. Em relação ao tempo necessário para ferida estar apta para a cirurgia de retalho, o Grupo USP apresentou um resultado de 9,6±4,5 dias. O Grupo VAC apresentou 12,8±8,6 dias. A diferença não foi estatisticamente significante (p=0,379). Em relação ao aumento de tecido de granulação por dia de tratamento, os dois métodos apresentaram resultados semelhantes: USP= 5,79 ± 2,93% e VAC 5,06 ± 5,15% (p=0,408). Em relação à variação de área, os dois grupos apresentaram um aumento: USP 1,13 ±0,80% e VAC 1,12 ± 0,80% (p=0,934). Foi observada uma importante diferença entre os custos do tratamento. O tratamento no Grupo USP custou, em média, R$ 47,89; enquanto o tratamento no grupo VAC, R$ 2.757,40. Conclusão: A terapia USP de tratamento de feridas por pressão negativa não é inferior à terapia VAC system® no tratamento de feridas complexas de origem traumática / Negative Pressure Wound Therapy (NPWT) was approved by the FDA in 1996 and since then has become widely adopted for a broad range of wounds. NPWT has many indications, both acute and chronic, and has brought great comfort to patients, caregivers, doctors, and nurses. Some authors suggest that NPWT may be used in traumatic wounds when primary closure is not possible after or in between debridements as a bridge to definitive closure. The big real obstacle to this useful procedure is the cost, which remains expensive for prolonged indications, making it unaffordable where these dressings are needed. In 2007 the University of São Paulo developed a low-cost NPWT based in a pressure stabilizer device (Curavac VX 200®, Ventrix Health Innovation, Brazil) connected to the hospital wall-vacuum and a gauzed-sealed dressing. No randomised trial has compared USP Negative Pressure Wound Therapy with the commercial vacuum assisted closure device (VAC system®). Our choice of a non-inferiority trial was based on the expectation that the time necessary for the improvement of the wound bed for patients treated with the USP therapy was no worse than the improvement time for VAC System (primary outcome). The wound bed area variation and granulation tissue growth were also assessed as secondary outcomes. In relation to the time (measured in days) necessary for the wound bed to became ready for the flap surgery, the USP group presented 9,6 ± 4,5 days. The VAC group presented 12,8 ± 8,6 days. The difference was not statistical significant (p=0,379). In relation to granulation tissue increase the two methods of NPWT (USP and VAC) presented very similar results: USP= 5,79( ± 2,93) and VAC 5,06 ( ± 5,15) (p=0,408). Regarding to wound area the both groups presented an increase: USP 1,13 ± 0,80 and VAC 1,12( ± 0,80) p=0,934. We observed an important difference in relation to treatment costs. The USP group treatment cost is about 2% compared with VAC group. Mean Treatment Cost: USP= US$ 15,15; VAC= US$ 872,59. Conclusion: The USP Negative Pressure Wound Therapy was non-inferior to VAC System for the treatment of complex traumatic injuries
16

Etude pilote sur l'innocuité et la faisabilité de l'emploi d'un système portable de thérapie par pression négative réalisée sur un modèle expérimental de plaies ouvertes chez le cheval

Kamus, Louis 08 1900 (has links)
No description available.
17

Manejo de heridas traumáticas de difícil cicatrización con colgajos microvasculares. / Microvascular free-flap reconstruction in acute hard-to-heal wounds

Ciudad, Pedro, Vargas, Maria I, Castillo-Soto, Ana, Sanchez, Jefferson R, Manrique, Oscar J, Bustos, Samyd S, Forte, Antonio J, Huayllani, Maria T, Soto, Zoila, Grández-Urbina, J Antonio 10 1900 (has links)
El texto completo de este trabajo no está disponible en el Repositorio Académico UPC por restricciones de la casa editorial donde ha sido publicado. / Objective: Present different flap alternatives when performing microvascular free-flap reconstruction in acute hard-to-heal wounds. Method: A retrospective review of patients whose acute hard-to-heal wounds were treated with microvascular free-flap reconstruction. Data on demographics, wound aetiology, diagnostic, previous treatment, free-flap type, free-flap size, complications and follow up were analysed. Results: A total of 20 patients received microvascular free-flap reconstruction. The median age was 39.5 years. Twenty free-flap reconstructions were performed. These included: 3 cross-leg free flap, 1 cross-leg vascular cable bridge flap, 2 fibula osteocutaneous flap, 6 anterolateral thigh (ALT) flap, 3 thoracodorsal artery perforator (TDAP) flap, 3 fasciomyocutaneous flap, and 2 femoral artery fasciocutaneous flap. A patient required microvascular anastomosis due to hematoma; the rest did not present complications during their postoperative. Previous treatment included negative pressure wound therapy (12 patients) and surgical debridement with silver hydrogel dressings (8 patients). Conclusion: Hard-to-heal wounds can be unresponsive to traditional wound healing practices or local flaps. They often require free-flap reconstruction, using tissues similar to those compromised. Microvascular techniques can be an effective alternative. CONFLICT OF INTEREST None.
18

Modelo animal de lavagem peritoneal contínua associada à peritoneostomia a vácuo / Animal model of continuous peritoneal lavage associated with vacuum laparotomy

Rodrigues Junior, Adilson Costa 14 August 2015 (has links)
Introdução: O tratamento das peritonites difusas, apesar dos avanços alcançados, continua difícil. Diversas técnicas e protocolos vêm sendo utilizados, porém esse casos seguem com altos índices de morbidade e mortalidade . O uso de peritoneostomias foi encorajado após o surgimento da terapia a vácuo, obtendo-se resultados promissores. Porém a lavagem peritoneal contínua ainda é uma modalidade considerada tecnicamente de difícil execução e de resultados controversos. Nesse experimento desenvolvemos e propomos um novo modelo de lavagem peritoneal continua que aproveitasse a facilidade e os benefícios da peritineostomia a vácuo. Métodos: Projeto piloto com 2 porcos foi realizado para padronização do posicionamento dos materiais e confecção da peritoneostomia que melhor se adaptasse ao modelo de lavagem contínua. Outros 12 porcos anestesiados 12 porcos, mantidos sob ventilação mecânica, recebendo solução de Ringer lactato 5ml/kg/h e monitorização continua. Submetidos a laparotomia mediada, posicionado dois tubos multi-perfurados 4.8mm nos flancos, confeccionado uma peritoneostomia a vácuo (Vivano® Hartmann) e aplicada pressão negativa 125mmHg. Para avaliação da integridade do sistema e efeitos fisiológicos da lavagem peritoneal continua, 8 porcos foram divididos em 2 grupos: em 4 deles foi Infundido através dos tubos multi-perfurados solução fisiológica (SF 0,9%), e nos outros 4 foi infundido solução de diálise peritoneal com dextrose 1,5% (SDPD 1,5%). Para avaliar a eficiência do sistema em alcançar todos os espaços e recessos intra-abdominais foi infundido solução de partículas de carbono em suspensão (nanquim) diluídas em SF 0,9%, e obtido imagens de tomografia computadorizada Nos mesmos animais foi testado a eficiência do clearance de fluido utilizado na lavagem peritoneal, observando a remoção da solução de nanquim diluída através da peritoneostomia. Resultados: Exames de imagem obtidos através de tomografia computadorizada, após infusão de fluidos, mostraram que o método é capaz de ocupar todos os espaços e recessos intra-abdominais. Apresentou também um clearance de fluido abdominal adequado com remoção progressiva de partículas de carbono em suspensão. Outro resultado importante foi a estabilidade da peritoneostomia a vácuo em conjunto com a infusão continua de fluidos. Não houve vazamentos ou obstrução dos cateteres durante todo procedimento. Notou-se que liquido infundido foi praticamente reabsorvido. Parâmetros hemodinâmicos e bioquímicos se mantiveram dentro da normalidade com a utilização de SDPD 1,5%, resultado não obtido com a utilização de SF 0,9%. Conclusão: Este modelo de lavagem peritoneal contínua é tecnicamente executável e mantem parâmetros fisiológicos dentro da normalidade quando utilizado SDPD 1,5% / Background: Treatment of diffuse peritonitis remains a challenge. With the advent of vacuum therapy, the use of laparotomy to treat peritonitis has gained attraction. However maintaining a continuous peritoneal lavage is technically difficult and has controversial results. In this experiment we have developed and proposed a new model of continuous peritoneal lavage taking advantage of the features and benefits of the vacuum laparotomy. Methods: Pilot project with two pigs was performed to standardize the positioning of materials and making of laparostomy that best suited to the model of continuous peritoneal lavage. Another 12 pigs under effects of general anesthesia and permanent hemodynamic monitoring were submitted to laparotomy. Then a multi-perforated tube was placed along each flank and exteriorized in the left and right lower quadrants of the abdomen. A vacuum dressing was placed and negative pressure was maintained with it. To evaluate the integrity in the system and physiological effects of continuous peritoneal lavage, A group of 8 pigs were divided into 2 sub-groups: The first sub-group of 4 animals received through multiperforated tubes peritoneal dialysis solution with Dextrose 1,5% (PDSD 1,5%) and the second subgroup of 4 pigs received saline solution 0,9% (SS 0,9%). To asses the system\'s efficiency in reach all intra-abdominal spaces and recesses, carbon particles in suspension (China Ink) diluted in SS 0,9% was infused into the abdominal cavity in all 8 pigs, this was followed by computerized tomography (CT) images. In addition, the same pigs were used to evaluate the efficiency of the intra-abdominal fluid clearance analyzing the washing of china ink diluted in SS 0,9% that was infused into the abdominal cavity. Results: Imaging obtained by Computerized tomography after fluid infusion showed that this method has a trend towards occupy all intra-abdominal spaces and recesses. It showed also an appropriate clearance of abdominal fluid with progressive removal of carbon particles in suspension. Dressing integrity was not compromised through out the duration of the study. There were no leaks or blockage of the catheters during the procedure. It was noted that all the liquid infused was almost reabsorbed. Hemodynamic and biochemical parameters remained within normal limits when SDPD 1,5% was used. This homeostasis was not achieved with SS 0,9%. Conclusion: This model of continuous peritoneal lavage is technically feasible, maintain physiological parameters within the normal range when SDPD 1.5% is used
19

Pressão exercida por sistema de pressão subatmosférica usado para fixação de enxerto de pele no tratamento de ferida cutânea. Estudo comparativo entre a tela de poliamida revestida de silicone e a tela de rayon como material de interposição / Pressure exerted by subatmospheric pressure system used for fixation of skin graft in the treatment of cutaneous wound. Comparative study between the silicon coated polyamide mesh and the rayon mesh as interposition material

Nogueira, Flávio Marques 10 August 2017 (has links)
Introdução: O tratamento de feridas cutâneas é difícil e está em contínua mudança. Entre as múltiplas terapias empregadas uma bastante usada é a enxertia de pele autógena. Sabe-se que o sucesso desta técnica depende, em parte, de haver condições adequadas no leito receptor e da qualidade do enxerto de pele retirado. Ainda, tão importante quanto a técnica cirúrgica, é o método para fixação do enxerto de pele ao leito e respectivo cuidado pós-operatório. Tem sido frequente o uso da terapia de feridas por pressão subatmosférica para fixação e integração de enxertos de pele no tratamento de feridas e habitualmente se coloca uma tela entre a esponja e o enxerto. Não há padronização na literatura médica sobre o que utilizar na tela. Objetivo: Comparar duas telas utilizadas e aferir o quanto cada uma interferia na pressão subatmosférica gerada pela unidade de aspiração contínua da terapia de feridas por pressão subatmosférica, por sua vez configurada para gerar um gradiente de pressão de 125 mmHg em relação à pressão atmosférica ambiente. Métodos: Foram realizados inicialmente dois estudos em voluntários normais para aferir a pressão subatmosférica sob a tela de rayon e sob a tela de poliamida, sobre a pele íntegra. Em um grupo de 30 indivíduos, as medidas foram feitas em tempos diferentes, montando-se e desmontando-se todo conjunto da esponja e de determinada tela sucessivas vezes. Em outro grupo de 15 indivíduos, as medidas foram feitas sequencialmente e com as sondas colocadas em conjunto, sendo metade da esponja sobre a tela de rayon e a outra metade sobre a tela de poliamida. A seguir, foi realizado estudo prospectivo com 30 pacientes portadores de feridas complexas, nos quais a terapia de feridas por pressão subatmosférica foi aplicada. Foram utilizadas tela de rayon e tela de poliamida em cada metade da área enxertada sobre a ferida. A pressão subatmosférica foi aferida sob cada tela e sob a esponja. Resultados: Os resultados mostraram diferença estatisticamente significativa entre as pressões sob as duas telas estudadas e em relação à pressão sob a esponja. Houve apenas uma perda completa de enxerto de pele. Conclusão: Concluiu-se que as diferentes telas estudadas reduziram a pressão subatmosférica gerada pelo dispositivo de aspiração contínua da Terapia de Feridas por Pressão Subatmosférica (TFPS) em comparação com a pressão medida como controle. / Introduction: Wound care is a difficult and ever changing field. Among many therapies employed, autogenous skin grafting is often used. The quality of the skin graft and appropriate conditions of the recipient bed are paramount for the success of this surgical procedure. Moreover, the method of skin graft fixation and postoperative care are as important as the surgical technique itself. Hence, subatmospheric pressure wound therapy has been used in the process of fixation and integration of skin grafts in the treatment of wounds when there is frequently a layer between the sponge and the graft. Thus far there has been no standardization in the medical literature as to which layer to use. Objective: Compare two layers and measure how much each one alone interfered in the subatmospheric pressure generated by the pump used in subatmospheric pressure wound therapy, when set to generate a pressure gradient of 125 mmHg in relation to the atmospheric pressure of the surroundings. Methods: Two pilot studies were, therefore, undertaken of normal volunteers to ascertain the subatmospheric pressure under the rayon layer, under the polyamide layer and under the sponge. In one pilot study, of a total of 30 individuals, their measurements were taken in different moments and the setting was mounted and unmounted three times. In another, of 15 individuals, the measurements were collected within just one setting, as half of the sponge had rayon underlying it and the other half had polyamide beneath it. Therefore another prospective study was undertaken of 30 patients bearers of complex wounds in which both the rayon and the polyamide layer was used for each half of the skin grafted area The subatmospheric pressure measured under each layer and directly under the sponge (control measure) was assessed. Results: The results showed statistically significant differences between the pressure measured on the two layers studied and the pressure measured under the sponge. There was only one total skin graft loss. Conclusion: In conclusion, it was found that the different layers studied did reduce the subatmospheric pressure generated by the pump used in subatmospheric pressure wound therapy as compared with the respective control measure.
20

Modelo animal de lavagem peritoneal contínua associada à peritoneostomia a vácuo / Animal model of continuous peritoneal lavage associated with vacuum laparotomy

Adilson Costa Rodrigues Junior 14 August 2015 (has links)
Introdução: O tratamento das peritonites difusas, apesar dos avanços alcançados, continua difícil. Diversas técnicas e protocolos vêm sendo utilizados, porém esse casos seguem com altos índices de morbidade e mortalidade . O uso de peritoneostomias foi encorajado após o surgimento da terapia a vácuo, obtendo-se resultados promissores. Porém a lavagem peritoneal contínua ainda é uma modalidade considerada tecnicamente de difícil execução e de resultados controversos. Nesse experimento desenvolvemos e propomos um novo modelo de lavagem peritoneal continua que aproveitasse a facilidade e os benefícios da peritineostomia a vácuo. Métodos: Projeto piloto com 2 porcos foi realizado para padronização do posicionamento dos materiais e confecção da peritoneostomia que melhor se adaptasse ao modelo de lavagem contínua. Outros 12 porcos anestesiados 12 porcos, mantidos sob ventilação mecânica, recebendo solução de Ringer lactato 5ml/kg/h e monitorização continua. Submetidos a laparotomia mediada, posicionado dois tubos multi-perfurados 4.8mm nos flancos, confeccionado uma peritoneostomia a vácuo (Vivano® Hartmann) e aplicada pressão negativa 125mmHg. Para avaliação da integridade do sistema e efeitos fisiológicos da lavagem peritoneal continua, 8 porcos foram divididos em 2 grupos: em 4 deles foi Infundido através dos tubos multi-perfurados solução fisiológica (SF 0,9%), e nos outros 4 foi infundido solução de diálise peritoneal com dextrose 1,5% (SDPD 1,5%). Para avaliar a eficiência do sistema em alcançar todos os espaços e recessos intra-abdominais foi infundido solução de partículas de carbono em suspensão (nanquim) diluídas em SF 0,9%, e obtido imagens de tomografia computadorizada Nos mesmos animais foi testado a eficiência do clearance de fluido utilizado na lavagem peritoneal, observando a remoção da solução de nanquim diluída através da peritoneostomia. Resultados: Exames de imagem obtidos através de tomografia computadorizada, após infusão de fluidos, mostraram que o método é capaz de ocupar todos os espaços e recessos intra-abdominais. Apresentou também um clearance de fluido abdominal adequado com remoção progressiva de partículas de carbono em suspensão. Outro resultado importante foi a estabilidade da peritoneostomia a vácuo em conjunto com a infusão continua de fluidos. Não houve vazamentos ou obstrução dos cateteres durante todo procedimento. Notou-se que liquido infundido foi praticamente reabsorvido. Parâmetros hemodinâmicos e bioquímicos se mantiveram dentro da normalidade com a utilização de SDPD 1,5%, resultado não obtido com a utilização de SF 0,9%. Conclusão: Este modelo de lavagem peritoneal contínua é tecnicamente executável e mantem parâmetros fisiológicos dentro da normalidade quando utilizado SDPD 1,5% / Background: Treatment of diffuse peritonitis remains a challenge. With the advent of vacuum therapy, the use of laparotomy to treat peritonitis has gained attraction. However maintaining a continuous peritoneal lavage is technically difficult and has controversial results. In this experiment we have developed and proposed a new model of continuous peritoneal lavage taking advantage of the features and benefits of the vacuum laparotomy. Methods: Pilot project with two pigs was performed to standardize the positioning of materials and making of laparostomy that best suited to the model of continuous peritoneal lavage. Another 12 pigs under effects of general anesthesia and permanent hemodynamic monitoring were submitted to laparotomy. Then a multi-perforated tube was placed along each flank and exteriorized in the left and right lower quadrants of the abdomen. A vacuum dressing was placed and negative pressure was maintained with it. To evaluate the integrity in the system and physiological effects of continuous peritoneal lavage, A group of 8 pigs were divided into 2 sub-groups: The first sub-group of 4 animals received through multiperforated tubes peritoneal dialysis solution with Dextrose 1,5% (PDSD 1,5%) and the second subgroup of 4 pigs received saline solution 0,9% (SS 0,9%). To asses the system\'s efficiency in reach all intra-abdominal spaces and recesses, carbon particles in suspension (China Ink) diluted in SS 0,9% was infused into the abdominal cavity in all 8 pigs, this was followed by computerized tomography (CT) images. In addition, the same pigs were used to evaluate the efficiency of the intra-abdominal fluid clearance analyzing the washing of china ink diluted in SS 0,9% that was infused into the abdominal cavity. Results: Imaging obtained by Computerized tomography after fluid infusion showed that this method has a trend towards occupy all intra-abdominal spaces and recesses. It showed also an appropriate clearance of abdominal fluid with progressive removal of carbon particles in suspension. Dressing integrity was not compromised through out the duration of the study. There were no leaks or blockage of the catheters during the procedure. It was noted that all the liquid infused was almost reabsorbed. Hemodynamic and biochemical parameters remained within normal limits when SDPD 1,5% was used. This homeostasis was not achieved with SS 0,9%. Conclusion: This model of continuous peritoneal lavage is technically feasible, maintain physiological parameters within the normal range when SDPD 1.5% is used

Page generated in 0.1243 seconds