Spelling suggestions: "subject:"obturados""
41 |
Influência da agitação ultrassônica do cimento obturador na ação antimicrobiana intra-dentinária e no preenchimento de istmos em canais mesiais de molares inferiores / Influence of ultrasonic agitation of the sealer on the intratubular antimicrobial activity and on the filling quality of isthmuses in mesial roots of mandibular molarsAlcalde, Murilo Priori 12 June 2015 (has links)
Avaliou-se presença de espaços vazios, presença de fendas na interface cimento/dentina, o perímetro de penetração do cimento obturador nos canais e nos istmos.e a ação antimicrobiana intra-dentinária do cimento endodôntico (AH Plus) quando submetido ou não a agitação ultrassônica no momento da obturação. Para a avaliação do preenchimento de istmos foram utilizadas 30 raízes mesiais de primeiros molares inferiores, as quais foram divididas em 2 grupos (n=15). A instrumentação foi realizada com o sistema reciprocante Reciproc (R25) e finalizado com instrumento rotatório Mtwo (35.04). Em seguida, o cimento AH Plus foi espatulado com Rodamina B e foi inserido nos canais com espiral de Lentulo no35; o cimento do grupo 1 foi submetido a agitação ultrassônica enquanto o do grupo 2 não foi agitado, sendo que todos os canais foram obturados por meio da técnica do cone único e armazenados em estufa a 37oC durante 7 dias. As raízes foram seccionadas transversalmente a 2, 4 e 6 mm do ápice radicular para análise em esteromicroscópio e microscopia confocal a laser. Para a avaliação da ação antimicrobiana foram utilizados 30 incisivos de bovinos, os quais foram seccionados em cilindros de 6 mm de espessura. Os canais tiveram seu diâmetro padronizado com uma lima tipo K no 80 e então contaminados com Enterococcus faecalis (ATCC 29212) por 4 dias. Após esse período os espécimes foram divididas em 3 grupos (n=30). No grupo 1 o cimento foi agitado com o ultrassom e obturados com a técnica de cone único; no grupo 2 o cimento não foi agitado e o grupo 3 foi o grupo controle. As raízes foram seccionadas longitudinalmente no sentido vestíbulopalatino e coradas com corante LIVE/DEAD para avaliar a viabilidade bacteriana em microscopia confocal a laser. Para análise da agitação ultrassônica do cimento obturador no preenchimento de canais e istmos, foi utilizado o teste não paramétrico de Mann-Whitney (p <0.05) e para a análise da ação antimicrobiana intradentinária, foi utilizado o teste não paramétrico Kruskal-Waliis e o Teste Dunn (p <0.05). Os resultados indicaram que a agitação ultrassônica do cimento AH Plus favoreceu o preenchimento de istmos e a penetração intratubular. A agitação ultrassônica do cimento AH Plus reduziu significantemente a viabilidade bacteriana. Conclui-se que a agitação ultrassônica do cimento AH Plus favoreceu maior penetração intratubular, menor presença de fendas, menos espaços vazios e maior ação antimicrobiana. / In this study it was assessed the presence voids, gaps in the sealer/dentin interface, the intratubular sealer penetration in canals and isthmuses and intratubular antimicrobial effect of the AH Plus sealer when ultrasonic activation was performed during obturation. 30 mesial roots of mandibular first molars were selected and divided into 2 groups (n=15). Root canal instrumentation was performed with the reciprocating system Reciproc (R25) and finished with the Mtwo (35.04) rotary instrument. Then the AH Plus sealer was mixed with Rhodamine B and was inserted into the root canals with a Lentulo spiral #35. In group 1 the ultrasonic activation of the sealer was performed while in group 2 was not activated. Then, the root canal filling was performed using the single cone technique. After 7 days of storage the roots were sectioned at 2, 4 and 6 mm from the apex and analyzed in the stereomicroscope and by confocal laser scanner microscopy. To the antimicrobial test 30 bovine incisors cut into cylinders with 6 mm in thickness were used. The root canals diameter was standardized with a K file # 80 and then contaminated with Enterococcus faecalis (ATCC 29212) for 4 days. After this period the samples were divided into 3 groups (n = 30). In group 1 the ultrasonic activation of the sealer was perfomed and filled with single cone technique; in group 2 the sealer was not ultrasonic activated and in group 3 the canals were not obturated (control group). The roots were sectioned in the buccal-palatal direction and stained with LIVE / DEAD stain to assess the bacterial viability by confocal laser microscopy. For analysis of ultrasonic activation of the sealer on the filling quality of the canals and isthmuses, a non-parametric Mann-Whitney test (p <0.05) was used. For the analysis of the intradentin antimicrobial action, a Kruskal-Waliis nonparametric and Dunn\'s test was used (p <0.05). The results showed that the ultrasonic agitation of the AH Plus sealer favored the isthmus filling and the intratubular penetration. Also, the ultrasonic activation of AH Plus sealer reduced bacterial viability. It was concluded that the ultrasonic agitation of the sealer favored higher intratubular penetration, lower presence of gaps and voids and higher antimicrobial activity.
|
42 |
Avaliação do preparo biomecânico e da obturação de canais radiculares ovais promovidos pelos sistemas de instrumento único WaveOne, Reciproc e SAF / Evaluation of biomechanical preparation and obturation of oval canals using WaveOne, Reciproc and SAF single-file systemsVersiani, Marco Aurelio 22 March 2012 (has links)
O objetivo deste estudo ex vivo foi avaliar o preparo biomecânico e a obturação de canais radiculares ovais utilizando os sistemas ProTaper, WaveOne, Reciproc e Self-Adjusting File. Com esta finalidade avaliou-se: 1) área, perímetro, circularidade, diâmetro maior, diâmetro menor, área de superfície, volume e SMI após o preparo biomecânico, por meio de microtomografia computadorizada (μTC); 2) percentual volumétrico de espaços vazios após a obturação do canal, por meio de μTC; 3) resistência de união (RU) e tipo de falha ocorrida após teste de push-out; e 4) a interface dentina/material obturador em microscopia eletrônica de varredura (MEV). Cem caninos inferiores humanos foram escaneados no microtomógrafo SkyScan 1174v.2. Após o preparo do terço cervical dos canais, os dentes foram distribuídos em 4 grupos (n=25), de acordo com o sistema usado no preparo biomecânico: ProTaper; WaveOne; Reciproc; Self-Adjusting File (SAF). Após a segunda μTC, 18 espécimes de cada grupo foram redistribuídos em dois grupos (n=9), de acordo com a técnica de obturação: Técnica Modificada da Onda Contínua de Condensação e técnica recomendada pelo fabricante. Os sete espécimes restantes de cada grupo constituíram os grupos controle negativo e positivo. Após a TC dos espécimes obturados, as raízes foram seccionadas transversalmente em fatias de 1 mm de espessura correspondentes às regiões cervical, média e apical. A RU foi avaliada pelo teste de push-out e as falhas após desunião observadas em microscópio digital. Após preparo para MEV, avaliou-se a interface adesiva de forma qualitativa nominal e ordinal pelo estabelecimento e determinação de escores. No conjunto, a análise dos parâmetros avaliados no preparo biomecânico mostraram que as alterações mais significativas ocorreram nos grupos ProTaper e WaveOne. Os resultados no grupo Reciproc ficaram em um nível intermediário, enquanto as menores alterações foram observadas no grupo SAF (ANOVA, p<0,05). Em relação à obturação, a Técnica Modificada da Onda Contínua de Condensação apresentou menor percentual volumétrico de espaços vazios que a técnica recomendada pelo fabricante apenas no terço cervical (Kruskall-Wallis, p<0,05). Após o teste de push-out, a análise das médias indicou RU (MPa) significativamente maior nos espécimes obturados pela técnica do fabricante em comparação com a Técnica Modificada de Onda Contínua de Condensação (teste t para amostras independentes, p<0,05). Em todos os grupos foi verificado maior percentual de falhas adesivas, com predominância de falhas mistas na técnica do fabricante e de falhas adesiva na dentina na Técnica Modificada de Onda Contínua de Condensação. Em MEV, não houve tags na maioria dos espécimes obturados pela Técnica Modificada da Onda Contínua de Condensação e quando presentes, eram pequenos e irregularmente distribuídos. Nos espécimes obturados pela técnica recomendada pelo fabricante observou-se formação de tags longos e bem distribuídos, principalmente no terço apical (teste de Friedman, p<0,05). Concluiu-se que todos os sistemas resultaram em alterações nos parâmetros bidimensionais e tridimensionais do canal após o preparo biomecânico; a técnica recomendada pelo fabricante resultou em maior volume de espaços vazios no terço cervical e maior RU do material obturador do que a Técnica Modificada de Onda Contínua de Condensação. Obs: tese completa no site: https://rapidshare.com/files/963588082/Tese_Prof._Dr._Marco_Versiani_FORP_USP_2012.pdf (na pagina que abrir, clicar no botao \"download\"). / The purpose of this ex vivo study was to evaluate the biomechanical preparation and obturation of root canals using ProTaper, WaveOne, Reciproc and Self-Adjusting File systems. It was evaluated: 1) area, perimeter, roundness, major diameter, minor diameter, surface area, volume and SMI after biomechanical preparation, using microcomputed tomography (μTC), 2) percentage volume of voids in the obturation material by means of μTC, 3) bond strength (BS) and type of failure after the pushout test, and 4) the analysis of the interface dentin / filling material using scanning electron microscopy (SEM). One-hundred human mandibular canines were scanned in the SkyScan 1174v.2 device. After preparing the coronal third of the canals, the teeth were divided into 4 groups (n=25), according to the biomechanical preparation system used: ProTaper, WaveOne, Reciproc, and Self-Adjusting File (SAF). After the second TC, eigthteen specimens of each group were assigned to two groups (n=9), according to the obturation technique: the Modified Continuous Wave of Condensation Technique and the technique recommended by the manufacturer. The remaining seven specimens of each group were used as negative and positive controls. After scanning, the obturated specimens were sectioned perpendicularly to its long axis into 1-mm slice thickness of the coronal, middle and apical thirds. The bond strength (BS) was performed by the push-out test and, after dislodgments, the failures were observed in a digital microscope. The specimens were processed for SEM analysis to observe bonding interface formation and resin tag density using a four-step scale method. Overall, the analysis of the biomechanical parameters showed that the most significant changes in the root canal occurred in the ProTaper group and WaveOne groups. Reciproc results were in an intermediate level and smaller changes were observed in the SAF group (ANOVA, p<0.05). In the coronal third, the Modified Continuous Wave of Condensation Technique showed a lower percentage volume of voids than the technique recommended by the manufacturer (Kruskal-Wallis test, p<0.05). After the push-out test, the analysis indicated the mean BS (MPa) was significantly higher in specimens filled by the manufacturer\'s technical than the Modified Continuous Wave of Condensation Technique (t test for independent samples, p<0.05). The adhesive failures were frequent in all groups. The Modified Continuous Wave of Condensation Technique showed the highest percentage of adhesive failure in dentin while in the technique recommended by the manufacturer, mixed failure was predominant. Overall, in SEM analysis, no tags were observed in most of the specimens filled by the Modified Continuous Wave of Condensation Technique. When present, they were small and irregularly distributed. The specimens filled by the technique recommended by the manufacturer showed long and well-distributed tags, especially in the apical third (Friedman test, p<0.05). It was concluded that all systems promoted root canal changes after the biomechanical preparation, the obturation technique recommended by the manufacturer resulted in a higher volume of voids in the coronal third and BS of the Modified Continuous Wave of Condensation Technique group.
|
43 |
Avaliação das propriedades físico-químicas dos cimentos obturadores dos canais radiculares à base de ionômero de vidro e silicone / Comparison of physicochemical properties of an ionomer-based and two silicon-based endodontic sealers.Flores, Daniel Silva Herzog 17 December 2009 (has links)
Este estudo avaliou, in vitro, tempo de endurecimento (TE), alteração dimensional (AD), solubilidade (Sl) e radiopacidade (Rp) dos cimentos AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill e um cimento experimental à base de MTA. Para estes testes o cimentos Activ GP foi manipulado na relação pó/líquido de 28 mg para 50 µL de líquido. Para determinar o TE, moldes (10 X 2 mm) foram preenchidos com cimento e, decorridos 150 s, os cimentos foram testados com agulha tipo Gillmore (100 g), a cada 60 s, até que não houvesse marcas na superfície. Para o teste de alteração dimensional, 5 corpos-de-prova cilíndricos (3,58 x 3,0 mm) foram obtidos. Após a mensuração de seus comprimentos por meio de parquímetro digital, foram imersos em 2,24 mL de água destilada e deionizada por 30 dias e mensurados novamente. Para o teste de Sl, foram obtidos 10 corpos-de-prova (1,5 X 7,75 mm). Após serem pesados, dois a dois, foram imersos em 7,5 mL de água destilada por 7 dias e pesados novamente, determinando-se a perda percentual da massa. Os líquidos de imersão foram submetidos à espectrometria para detecção dos íons Ca2+, K+, Ni2+, Pb2+, Zn2+, Ag+. Para a Rp, 5 placas de acrílico com 4 perfurações (5 X 1 mm) foram preenchidas com cimento e, ao lado de escada de alumínio padronizada, foram radiografadas com distância foco-objeto de 30 cm e exposição de 0,2 s. A densidade radiográfica foi determinada por meio do Digora for Windows 1.51. Os resultados mostraram que os cimentos GuttaFlow e RoekoSeal estavam de acordo com a Especificação n° 57 da ANSI/ADA para os testes de TE e Rp. Em relação a ED, somente o Guttaflow estava de acordo com esta Especificação. Em relação à Sl, somente o cimento Activ GP (11,80%) não atendeu os padrões exigidos pela ANSI/ADA. A espectrometria de absorção atômica mostrou que o cimento Activ GP apresentou liberação expressiva de ions Ca2+. A liberação de ions Zn2+ foi evidenciada no cimento Activ GPl. Concluiu-se que somente cimento Guttaflow atendeu às exigências da ANSI/ADA em relação à radiopacidade, estabilidade dimensional e solubilidade. / This study evaluated, in vitro, the setting time (ST), dimensional alteration (DA), solubility (Sl) and radiopacity (Rp) of the sealers AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill and a MTA-based experimental sealer. For these tests, the sealer Activ GP was prepared using a powder/liquid mixing ratio of 28 mg to 50 µL of liquid. In order to determine the ST, moulds (10 x 2 mm) were filled with sealer. After 150 s, the sealers were tested with a Gilmore needle (100 g) at 60-s intervals until no marks were visible on the material surface. For the DA test, 5 cylindrical specimens (3.58 x 3.0 mm) were obtained. After having their dimensions checked with a digital caliper, the specimens were stored in 2.24 mL distilled deionized water for 30 days and their dimensions were rechecked. For the Sl test, 10 specimens (1.5 x 7.75 mm) were obtained. After being weighed in pairs, the specimens were stored in 7.5 mL distilled water for 7 days and reweighed to determine the percent mass loss. The liquids in which the specimens were immersed were subjected to spectrometry for detection of ions Ca2+, K+, Na+, Ni2+, Pb2+, Zn2+and Ag+. For the Rp test, 5 acrylic plates with 4 perforations (5 x 1 mm) were filled with sealer and were radiographed near to a graduated aluminum stepwedge with 30-cm focus-object distance and 0.2-s exposure time. The radiographic density was determined using the Digora for Windows 1.51 software. The results showed that GuttaFlow and RoekoSeal were in compliance with the ANSI/ADAs specification no. 57 for the TE and Rp tests. Regarding DA, only GuttaFlow was in accordance with this specification. Regarding Sl, only Activ GP (11.80%) did not meet the ANSI/ADAs requirements. The atomic absorbance spectrometry showed that the sealer Activ GP presented significant release of Ca2+. Release of Zn2+ ions was observed for the sealer Activ GP. In conclusion, only the sealer Guttaflow met the ANSI/ADAs requirements for radiopacity, dimensional stability and solubility.
|
44 |
Avaliação da reação tecidual e da radiopacidade do cimento Portland acrescido de diferentes concentrações de óxido de bismuto: estudo em tecido subcutâneo de ratos / Radiopacity and rat subcutaneous tissue response to Portland cement containing different concentrations of bismuth oxideSilva, Marina Angélica Marciano da 24 May 2011 (has links)
A radiopacidade e a resposta tecidual do cimento Portland (CP) acrescido de óxido de bismuto (OB) nas concentrações de 0, 15, 20, 30 e 50%, determinadas em peso, foram avaliadas. Para a análise da radiopacidade, foi seguida a norma ISO 6876/2001. A densidade radiográfica foi mensurada em milímetros de alumínio (mmAl) e a análise estatística realizada utilizando-se os testes de ANOVA e Tukey-Kramer (p<0,05). Para a análise da resposta tecidual foram selecionados 81 ratos albinos e cada um recebeu como implante, na região dorsal, dois tubos de polietileno preenchidos com os cimentos experimentais. Os ratos foram mortos após 15, 30 e 60 dias. Na análise microscópica foram avaliados dois parâmetros: células inflamatórias e fenômeno reparatório. Os escores foram determinados e submetidos à análise estatística, utilizando-se os testes não paramétricos de Kruskal-Wallis e Dunn (p<0,05). Os resultados demonstraram que os valores representativos da radiopacidade aumentaram, gradativamente, de acordo com a concentração de óxido de bismuto. A significância estatística foi verificada entre o CP/50%OB e os demais cimentos avaliados, e entre o CP puro e o CP/30%OB (p<0,05). A radiopacidade apresentada pelo CP puro foi abaixo do mínimo (3 mmAl) recomendado pelas normas nº 57 da ADA e da ISO 6876/2001. Na análise da resposta tecidual, em relação à intensidade do infiltrado inflamatório, ocorreu diminuição de 15 para 30 dias e de 15 para 60 dias, com significância estatística (p<0,05), apenas para o grupo II nos dois intervalos de tempos. Com referência ao fenômeno reparatório ocorreu, em geral, para todos os grupos aumento do tecido fibrocelular, do período de 15 para o de 60 dias. Os resultados obtidos permitiram concluir que 15 a 20% de óxido de bismuto é suficiente para proporcionar ao CP a radiopacidade mínima recomendada pelas normas ADA e ISO. A diminuição do infiltrado inflamatório associada ao aumento do tecido fibrocelular, fundamentam a ausência de citotoxicidade do óxido de bismuto incorporado ao CP. / The aim of the study was to evaluate the radiopacity and subcutaneous tissue response of Portland cement (PC) with different concentrations of bismuth oxide (BO). PC was mixed with 0, 15, 20, 30 and 50% of BO determined in weight. The radiopacity was performed according to the ISO 6876/2001 standard for dental root canal sealing materials Statistical analysis was performed using ANOVA and Tukey-Kramer tests (p<0.05). For biocompatibility test, eighty-one albino rats (Rattus norvegicus) were selected. Two subcutaneous pockets were created in animal dorsum and polyethylene tubes filled with the cements were implanted. The rats were sacrificed at 15, 30 and 60 days after implantation. Histological evaluations were classified according to inflammatory response and repair process and scores were established. Statistical analysis was performed using the Kruskal-Wallis and Dunn tests (p<0.05). The results showed that there were statistical differences in radiopacity among PC with 50% of BO and all the other evaluated concentrations (p<0.05). Also, there was statistical difference between PC with 30% of BO and PC without BO (p<0.05). No statistical differences were found for inflammatory response in all the evaluated groups in each period (p>0.05). For repair process evaluation was observed a significant increase in fiber cellular tissue through the periods for all the groups (p<0.05). The tests suggested that 15 to 20% of BO added to PC attended ISO requirements for radiopacity. For biological response, there were decreases in the inflammatory response associated with an increase in the repair process, suggesting the lack of toxicity of BO added to PC.
|
45 |
Comparação do selamento das técnicas de cone único modificada, condensação lateral e termoplastificada por onda contínua de condensação / Evaluation of sealing ability of modified single-cone, lateral condensation and continuous wave of condensation obturation techniquesNabeshima, Cleber Keiti 13 September 2011 (has links)
A proposta deste estudo foi avaliar a infiltração bacteriana em dentes obturados pela técnica de condensação lateral, cone único modificada e termoplastificada por onda contínua de condensação. Quarenta e nove raízes disto-vestibulares de molares superiores padronizados no limite de trabalho de 9 mm foram instrumentados com sistema ProTaper até lima F2, e assim divididos em 3 grupos (n=15) de acordo com a técnica de obturação: G1 cone único modificada, G2 condensação lateral, e G3 - termoplastificada por onda contínua de condensação e injeção de guta percha. O grupo controle positivo foram 2 espécimes sem obturação, e o grupo controle negativo foram 2 espécimes obturados pela técnica de condensação lateral e abertura coronária selada com cianoacrilato. As raízes foram impermeabilizadas deixando 2 mm apicais livre e montadas no aparato de duplo compartimento. Após esterilização com óxido de etileno, 3 ml de TSB estéril foi inoculado no compartimento inferior, e 400 l de caldo contendo Enterococcus faecalis no compartimento superior. A nutrição bacteriana foi realizada a cada 48 h através da retirada de 200 l de caldo bacteriano e adição de 200 l de TSB. O TSB contido no compartimento inferior foi checado a cada 48 h para verificar presença de turvamento num período experimental de 30 dias. O grupo controle positivo infiltrou em 24 h, e nenhum controle negativo apresentou infiltração em 30 dias. No tempo experimental, o grupo do cone único modificado apresentou 73,3% das amostras infiltradas, a condensação lateral apresentou 66,6%, e a termoplastificada 53,3%, não havendo diferença significante entre os grupos aplicando-se os testes do Quiquadrado e Kruskal-Wallis (p>0.05). Pode-se concluir que a técnica de cone único modificada apresenta capacidade de selamento semelhante à técnica de condensação lateral e termoplastificada por onda contínua. / The aim of this study was to evaluate bacterial leakage in root canals obturated with lateral condensation, modified single-cone and continuous wave of condensation techniques. Forty-nine distobuccal root canals of upper molars were standardized with 9 mm of working length. Then the canals were shaped by ProTaper Rotary system up to F2, and divided in three groups (n=15) according to obturation technique: G1 modified single-cone, G2 lateral condensation and G3 continuous wave of condensation. The positive control was two no obturated root canals, and positive control two root canals obturated with lateral condensation technique and coronal opening sealed with cyanoacrylate. The roots external surfaces were sealed, except for the apical 2 mm around the apical foramen, and the bacterial leakage model of two chambers was used. After sterilization by ethylene oxide gas, 3 ml of TSB was poured into the lower chamber, and 400 l of soy broth containing Enterococcus faecalis was inoculated into the upper chamber. Bacterial nutrition was performed each through changing of 200 l of bacterial soy broth to 200 l of TSB. The TSB placed in the lower chamber was checked each 48 h to verify turbidity on the experimental period of 30 days. The positive control leaked within 24 h, and the negative control no leaked on 30 days. In the experimental period, modified single-cone technique showed leakage of 73,3% samples, lateral condensation showed 66,6%, and wave continuous of condensation 53,3%. There were no significant difference between the groups according to Chi-square and Kruskal-Wallis tests (p>0.05). It can be concluded that modified single-cone technique shows sealing ability semelhante to lateral condensation and continuous wave of condensation techniques.
|
46 |
Infiltração bacteriana em canais radiculares obturados com diferentes cimentos endodônticos e duas técnicas obturadoras / Bacterial leakage in root canals filled with different endodontic sealers and two techniquesCunha, Thais Vieira Rizzo Nunes da 27 June 2011 (has links)
O objetivo deste estudo foi avaliar ex vivo a infiltração do Enterococcus faecalis em canais radiculares obturados com os cimentos endodônticos AHPlus, RealSeal e o cimento experimental Sealepox, pelas técnicas da condensação lateral e compactação vertical. Cem dentes humanos unirradiculados, com canais únicos e retos, tiveram os mesmos instrumentados, e após, as coroas removidas, para a realização das obturações. Aparatos específicos para a fixação das raízes foram confeccionados contendo meio de cultura estéril e específico para a bactéria, em questão. A inoculação deEnterococcus faecalis foi realizada e, durante 60 dias, o meio de cultura foi checado diariamente para constatar sua possível turvação, o que, caracterizaria a passagem bacteriana pela obturação. Todos os espécimes foram processados histologicamente e corados pela técnica de Brown e Brenn para exame em microscópio óptico, para constatação da presença e localização do Enteroccocus faecalis no interior dos canais radiculares e na massa dentinária. Considerando a metodologia da infiltração bacteriana, os resultados obtidos mostraram que nem os cimentos obturadores e nem as técnicas foram capazes de impedir a infiltração. Contudo, a mesma ocorreu em um pequeno número de espécimes, não sendo observadas diferenças significantes entre os cimentos e técnicas. Em relação à análise microscópica, foi observada a presença dos micro-organismos em, praticamente, todos os espécimes analisados. Tal observação permite afirmar que a metodologia da infiltração bacteriana não é confiável para se qualificar o selamento proporcionado por obturações de canais radiculares. / The aim of this study was to assess ex-vivo the leakage of Enterococcus faecalis in root canals filled with endodontic sealers AHPlus, RealSeal and the experimental sealer Sealepox, after the lateral condensation or warm vertical condensation techniques. One hundred single rooted extracted human teeth had their root canals instrumented and their crowns removed for the conducting of the obturation. An experimental bacterial leakage setup was designed for fixing the root canal in the contained media, sterile and specific for the bacteria in study. The inoculation with Enterococcus faecalis was conducted and for 60 days the media was checked daily for possible change in its clear aspect, which would than, characterize the contamination by the bacteria through the root canal. All the sample which were infiltrated, totally or not, were processed and colored by the Brown and Brenn technique for observation of presence and location of Enterococcus faecalis in the root canal or dentinal tubules. With the methodology for bacterial leakage considered, the results obtained showed that none of the sealer neither the techniques employed were able to avoid leakages. Nevertheless, leakage happened in a small number of samples, where no statistical difference could be found between sealers and techniques. In regards to the microscopy analysis, presence of microorganisms was observed in practically all the samples. Such an observation, suggests that bacterial leakage is not a trustworthy indicator for qualifying sealing obtained by sealers in root canals.
|
47 |
Análise da interface de adaptação de diferentes materias obturadores resinosos / Analysis of adaptation interface from different resin filling materialsVitoriano, Marcelo de Morais 25 June 2013 (has links)
Neste trabalho foi avaliado microscopicamente a interface de adaptação entre diferentes cimentos obturadores resinosos e dentina no interior do canal radicular de pré-molares humanos, identificando microscopicamente o nível de adaptação. Foram selecionadas 60 raízes de dentes uniradiculados, raízes retilíneas, com anatomia circular ou ovalada, ápices completos, obtidos por meio de doação feita por Cirurgião Dentistas e, consentidos seu emprego em pesquisas pelo paciente. Posteriormente as raízes foram divididas randomicamente em três grupos de acordo com o sistema de obturação empregado: Grupo 1 Guta-percha + cimento AHPlus; Grupo 2 Real Seal; Grupo 3 Sistema obturador smart-seal. Em seguida cada espécime recebeu cortes transversais em diferentes níveis, com 2mm de espessura, com disco diamantado, em máquina de corte de tecido duro (Isomet®) sob abundante irrigação. Após a realização dos cortes, as fatias a 2mm, 4mm, 6mm e 8mm foram analisadas em esteriomicroscópio, observando-se a área de adaptação cimento-dentina e em microscópio confocal para analisar a penetração do cimento em túbulos dentinários e a presença de fendas. As imagens obtidas foram analisadas pelo software de medida de área Image J®, em que as imagens foram devidamente calibradas. Os resultados apontaram uma superioridade do sistema Smart-seal na área de cimento no corte de 6mm (p<0,05), contudo uma inferioridade no que se tratou da penetração do cimento em túbulos dentinários nos cortes de 2mm, 6mm e 8mm (p<0,05). Em relação as fendas o smart-seal apresentou uma menor quantidade de fendas (p<0,05) apenas na medida de 8mm. Concluiu-se que apesar de sofrer expansão na tomada de presa, e melhor adaptação nas paredes do canal o sistema Smart Seal não apresentou penetrabilidade tubular satisfatória. / This study evaluated microscopically the interface adaptation between sealer and dentin within the root canal, identifying the level of sealing provided by different resin filling materials. 60 single rooted teeth were selected, roots straight with circular or oval anatomy, complete apexes, obtained through donation made by Surgeon Dentists and consented to its use in research by the patient. Subsequently the roots were randomly divided into three groups according to the system obturation: group 1 - Gutta-percha + cement AHPlus, Group 2 - Epiphany + Resilon, Group 3 - Smart Seal obturation system. Then each specimen received a transverse cut with 2 mm thick, with a diamond disc, cutting machine for hard tissue (Isomet ®) under abundant irrigation. After the cuts, slices to 2mm, 4mm, 6mm and 8mm were analyzed by esteriomicroscopy, observing the adaptation area between dentin and sealer, confocal microscopy was utilized to examine the penetration of cement into the dentinal tubules and the presence of gaps. The images were analyzed by software measurement area Image J ®, where the images have been properly calibrated. The results showed a superiority of Smart-seal in the area of cement in cutting 6mm (p <0.05), however inferiority in the penetration of the sealer into the dentinal tubules in sections of 2mm, 6mm and 8mm (p <0.05). Regarding the cracks Smart Seal had a smaller amount of cracks (p <0.05) only the extent of 8mm. It was concluded that although the Smart Seal system presentes expansion and better fit into the dentin walls of the canal, the system showed no satisfactory tubular penetration.
|
48 |
Avaliação in vitro do selamento apical produzido a partir de duas técnicas de aplicação de trióxido mineral agregado (MTA), em retro-preparos de raízes apicectomizadas. / In vitro evaluation of apical sealing ability produced from two mineral trioxide aggregate (MTA) placement techniques, in resected apical roots preparations.Manicardi, Cid Alonso 11 May 2005 (has links)
O propósito deste estudo foi avaliar se o selamento promovido pelo MTA quando utilizado como material retrobturador seria diferente se inserido por duas diferentes técnicas de aplicação e condensação. 45 incisivos superiores humanos foram divididos em 3 grupos de 15 espécimes cada. Após apicectomia e preparo apical com ultra-som, as cavidades foram preenchidas com MTA, aplicado e condensado manualmente (G I) ou por vibração ultra-sônica (G II e G III). O grupo G II recebeu o MTA com o ápice posicionado para cima e o grupo G III com o ápice para baixo a fim de verificar possíveis interferências gravitacionais. Após a obturação retrógrada, os espécimes foram avaliados por infiltração linear e por área, valendo-se do corante Rodamina B a 1%. A utilização da vibração ultra-sônica para aplicação do MTA no grupo G II resultou em infiltração significativamente menor do que a ocorrida do grupo G I. Houve também diferença estatística entre os grupos da técnica ultra-sônica, com ápice voltado para cima (G II) e para baixo (G III), o que demonstra haver influência gravitacional (p < 0,05). Tal diferença não foi detectada entre os grupos G I e G III. Diante dos resultados, o ultra-som pode ser considerado como um método alternativo de aplicação do MTA. / The purpose of this study was to evaluate if the sealing ability produced by MTA, when used as a root-end filling material, would differ when used by two different placement and condensation methods. 45 human superior incisors were divided into 3 groups of 15 specimens each. After root-end resection, they were prepared with ultrasonic instrumentation and preparations were filled with MTA, placed and condensed by hand (G I) or ultrasonic methods (G II and G III). The G III group had the apical portion upside down, to verify if gravity forces could interfere in the results.After retrograde obturation the specimens were evaluated by Rhodamine B 1% for linear and area dye leakage. The MTA ultrasonic vibration in the G II group resulted in a less dye leakage than in the G I group. There was statistical difference between ultrasonic methods with the apex upside up (G II) and upside down (G III) which demonstrate a gravitational influence in sealing ability (p < 0,05). This difference wasnt detected between G I and G III groups. At this time ultrasonic condensation should be considered as an alternative method for MTA placement.
|
49 |
Avaliação quantitativa e qualitativa da extrusão apical em técnicas de obturação termoplastificada. / Quantitative and qualitative evaluation of the apical extrusion in techniques of thermoplasticized obturation.Strefezza, Fábio 29 March 2004 (has links)
Atualmente, as técnicas de obturação com guta-percha termoplastificada têm mostrado eficiência na adaptação dos materiais obturadores às paredes do sistema de canais radiculares, promovendo um selamento tridimensional. Porém, com a utilização destas técnicas, há dificuldade no controle longitudinal durante a obturação, que poderia acarretar em extrusão do material obturador em direção aos tecidos perirradiculares, influenciando na reparação pós tratamento endodôntico. Assim, o propósito deste estudo foi avaliar in vitro a extrusão apical de quatro técnicas de obturação termoplastificada, Thermafil, Obtura II, Ultrafil 3D e Fusionada, através de uma nova metodologia de mensuração de volume do material obturador extruído, relacionando com a freqüência da extrusão visual de guta-percha e/ou cimento e a qualidade radiográfica final da obturação. Os resultados demonstraram que a metodologia do sistema de mensuração foi efetiva para quantificar o volume de material obturador extruído, constatando extrusão em todas as técnicas termoplastificadas empregadas neste estudo, porém, quantitativamente, os grupos experimentais não apresentaram diferenças estatisticamente significantes entre as médias de volumes. Na avaliação radiográfica da qualidade final das obturações termoplastificadas, há evidências de que a técnica Obtura II produziu obturações endodônticas com qualidades estatisticamente inferiores às demais técnicas. De modo geral, podemos considerar que as técnicas Thermafil, Ultrafil 3D e Fusionada apresentaram resultados semelhantes em relação ao volume do material obturador extruído e qualidade radiográfica final da obturação, enquanto que as técnicas Thermafil e Fusionada exibiram resultados mais favoráveis em relação à freqüência da extrusão visual de guta-percha e/ou cimento. / In the present, the obturation techniques with termoplasticized gutta-percha have been proving efficiency in adaptation of the filling material to the walls of the root canal system, promoting a three-dimensional sealing. Even so, with the use of these techniques, there is difficulty in the longitudinal control during the obturation, that could cause the extrusion of the filling material in direction to the perirradicular tissues, influencing the healing after endodontic treatment. Thus, the purpose of this study was to evaluate in vitro the apical extrusion of four thermoplasticized obturation techniques, Thermafil, Obtura II, Ultrafil 3D and Fused, with a new methodology of volume?s measurement of the extruded filling material, relating with the frequency of the visual extrusion of gutta-percha and/or sealer and the final radiographic\'s quality of obturation. The results demonstrated that the methodology of the measurement system was effective to quantify the volume of the extruded filling material, verifying extrusion in all the thermoplasticized techniques studied, even so, quantitatively, the experimental groups didn\'t present statistically significant differences among the averages of volumes. In the radiographic evaluation of the final quality of thermoplasticized obturation, there are evidences that Obtura II technique produced endodontic obturation with qualities statistically inferior of the other techniques. In general, we can consider that Thermafil, Ultrafil 3D and Fused techniques presented similar results in relation to the volume of the extruded filling material and the final radiographic\'s quality of obturation, while Thermafil and Fused techniques exhibited more favorable results in relation to frequency of visual extrusion of gutta-percha and/or sealer.
|
50 |
Análise "in vitro" da microinfiltração em retrobturação, utilizando diferente materiais retrobturadores e a influência da aplicação da Edta na cavidade retrógradaPelissari, Carlos Antonio 21 July 2004 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1
Carlos Antonio Pellissari.pdf: 1778484 bytes, checksum: 53efb541915c3a7f2e9f0a102717239b (MD5)
Previous issue date: 2004-07-21 / Although reaching high success rates there is a great number of root canals endodontically treated which don’t reach the wished results. In these cases there is
necessity to indicate the periapical surgery. Among the surgical kinds the most used is the conventional retrograde filling. This surgical modality has also impelled the main researches about the matter.The present study had the purpose to evaluate “in vitro”the microleakage when were used some retrofilling materials and also the influence of application of EDTA in the retrograde cavity before to be filled the canals.
They were used in this study seventy two mandibular and maxillary human canine teeth extracted for several reasons in Surgical Clinic of State University – Ponta Grossa – Pr – Brazil. Initially all teeth were instrumented and filled according to traditional technics of preparation and filling. After this the teeth had the apical portion
sectioned perpendicularly to tooth long axis and its external surface was made waterproof. After the apicectomy they were prepared cavities of approximately 3 mm
deep using the sonic equipment GNATUS ( JET- SONIC FOUR) with the point S12 with the angle of 90 with the active point with diamond with 3 mm long and a caliber
compatible to the most of teeth. The seventy two teeth were fortuitously distributed in six groups with twelve teeth each one according to the materials to be used. In three groups before the retrograde filling it was made an application of EDTA during 3 minutes in retrograde cavity. According to the procedures and the materials used in
retrofillings the six groups were so constituted: Group I – retrofilling with Sealapex+zinc oxide eugenol; Group II – retrofilling with IRM; Group III – retrofilling
with MTA; Group IV – application of EDTA and retrofilling with Sealapex+zinc oxide eugenol; Group V – application of EDTA and retrofilling with IRM; Group VI – application of EDTA and retrofilling with MTA. After the operative procedures and drying of the roots these were imersed in 2 methilene solution during sixty hours at 37C. After this period the roots were washed in current water during 12 hours and the proofing layer was removed. It was performed them the longitudinal wearing of the root till the exposition of the retrofilling material making possible the analysis of the leakage. To verify the extension of the leakage the teeth were photographed with digital camera and the images transported to the computer where they were analysed in a specific program called Mocha to measure the apical microleakage. The leakage
was measured from a root end to the more depth of leakage observed. The values of the leakages of each tooth in milimeters and the overages of the leakages were duly
ordered and submited to the statistical analysis from which we conclude: There wasn’t influence when it was applicated the EDTA in retrograde cavity before the use of the retrofilling materials evaluated; There are statistically significative differences when the
groups of retrofilling materials were compared and when the application of EDTA alone was analysed; The retrofilling material IRM presents the most degree of
marginal leakage; MTA was shown to be the best among the evaluated materials; Sealapex+zinc oxide eugenol didn’t present significative difference in relation to MTA;
EDTA used in retrograde cavity increased the degree of microleakage. / Embora atingindo altos índices de sucesso, há um grande número de canais radiculares, tratados endodonticamente, que não atingem os resultados desejados.Nesses casos há a necessidade da indicação da cirurgia parendodôntica.
Dentre as modalidades cirúrgicas a mais empregada ainda é a obturação retrógrada convencional. Essa modalidade cirúrgica tem motivado também a maioria das pesquisas. O presente trabalho teve como objetivo a análise “in vitro”da
microinfiltração, quando se utilizaram alguns materiais retrobturadores e também a influência da aplicação de EDTA na cavidade retrógrada, antes de serem retrobturados os canais. Foram utilizados no presente trabalho 72 dentes caninos humanos superiores e inferiores permanentes, extraídos por diversos motivos, na Clínica de Cirurgia da Universidade Estadual de Ponta Grossa. Inicialmente todos os
dentes foram instrumentados e obturados, segundo técnicas tradicionais de preparo e obturação. Após isso os dentes tiveram a porção apical seccionada perpendicularmente em relação ao longo eixo do dente e sua superfície externa
impermeabilizada. Após a apicectomia foram confeccionadas cavidades de aproximadamente 3 mm de profundidade, utilizando-se o aparelho de ultra-som Gnatus (Jet – Sonic Four) com a ponta S12, com ângulo de 90, com ponta ativa
diamantada com 3 mm de comprimento e um calibre que se aplica à maioria dos canais. Os 72 dentes foram então distribuídos aleatoriamente em 6 grupos experimentais com 12 dentes cada um, segundo os materiais a serem utilizados. Em
3 grupos, antes da obturação retrógrada, foi feita a aplicação de EDTA, por 3 minutos, na cavidade retrógrada. De acordo com os procedimentos e materiais utilizados na retrobturação, os 6 grupos experimentais foram assim constituídos:
Grupo I – Retrobturação com Sealapex + óxido de zinco e eugenol; Grupo II – Retrobturação com IRM; Grupo III – Retrobturação com MTA; Grupo IV – Aplicação de EDTA e retrobturação com Sealapex+óxido de zinco e eugenol; Grupo V – Aplicação de EDTA e retrobturação com IRM; Grupo VI – Aplicação de EDTA e retrobturação com MTA. Após a realização dos procedimentos operatórios e a secagem das raízes, essas foram imersas em solução de azul de metileno a 2%,por 60 horas a 37C.Decorrido esse período as raízes foram lavadas durante 12 horas em água corrente e a camada impermeabilizante removida. Realizou-se então o desgaste longitudinal da raiz no sentido vestíbulo-lingual até a exposição do material retrobturador, possibilitando assim a análise da infiltração do corante. Para verificação da extensão da penetração da solução corante os dentes foram fotografados com uma câmara fotográfica digital e as imagens levadas ao computador, onde foram analisadas em um programa específico chamado Mocha, para medir a microinfiltração apical. A infiltração foi medida a partir do extremo apical radicular, até a maior profundidade de infiltração observada. Os valores em milímetros das infiltrações de cada dente e as médias das infiltrações foram
devidademente tabulados e submetidos à análise estatística, levando-nos às seguintes conclusões: Não houve influência da aplicação do EDTA na cavidade, antes do uso dos materiais retrobturadores avaliados; Existem diferenças
estatisticamente significantes, quando comparados os grupos de materiais retrobturadores e quando analisada a aplicação do EDTA isoladamente; O material retrobturador IRM apresenta o maior grau de infiltração marginal; O MTA mostrou-se ser o melhor entre os materiais avaliados; O Sealapex+Óxido de zinco e eugenol não apresentou diferença significativa em relação ao MTA; O EDTA, utilizado na
cavidade retrógrada, provocou um aumento no grau de infiltração.
|
Page generated in 0.065 seconds