• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 99
  • 14
  • 1
  • Tagged with
  • 116
  • 30
  • 30
  • 28
  • 24
  • 21
  • 20
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Taxa de crescimento axial pós-operatório de olhos com catarata congênita e do desenvolvimento submetidos a facectomia com implante de lente intra-ocular / Axial growth rate postoperative eyes with congenital and development cataract submitted to phacectomy with intraocular lens implantation

Andrade, Guilherme Pessoni de [UNESP] 30 March 2015 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-30. Added 1 bitstream(s) on 2015-12-10T14:30:03Z : No. of bitstreams: 1 000849018.pdf: 133262 bytes, checksum: 79e5100459efce332b6b39f84987e89f (MD5) / OBJETIVO: Estabelecer, para olhos com catarata congênita e do desenvolvimento, modelos matemáticos para o cálculo da taxa de crescimento axial diário (TCA) e cálculo do comprimento axial (Axl) em qualquer idade futura, a partir da idade e do Axl medido, no momento da cirurgia. MÉTODOS: Estudo retrospectivo de crianças submetidas à facectomia com implante de LIO entre janeiro de 2011 a janeiro de 2014. Foram incluídas crianças com catarata não complicada sem patologias oculares e idade inferior a dez anos. Dados biométricos foram obtidos com biômetro de imersão. Procedeu-se a análise estatística dos dados e estabeleceu-se fórmulas matemáticas para cálculo da TCA e Axl. RESULTADOS: Foram operados 54 olhos de 33 crianças sendo 19 masculinos (57,58%) e 14 femininos (42,42%). Dos 33 casos analisados, 12 eram cataratas unilaterais (36,37%) e 21 eram cataratas bilaterais (63,63%). Nos casos de catarata bilateral utilizou-se apenas os dados do olho direito de cada criança. A amostra foi dividida em 3 grupos (cataratas unilaterais e bilaterais, cataratas unilaterais, cataratas bilaterais) e para cada grupo foi estabelecido uma fórmula matemática para cálculo da TCA e Axl. CONCLUSÕES: O presente estudo propõe uma nova maneira de abordagem no cálculo da LIO, não baseada em resultados refracionais pós-operatório mas em uma taxa de crescimento diário (TCA). As equações geradas permitem estabelecer a taxa de crescimento diária em qualquer idade e principalmente a permitem prever Axl futuro a partir de um Axl inicial medido. Não é possível concluir pelo presente estudo que o método proposto é superior a outros métodos de estimação do crescimento ocular. Estudos comparativos entre eles serão necessários para avaliar esta precisão / PURPOSE: Establish, for the eyes with congenital and development cataract, mathematical models to calculate the daily axial growth rate (AGR) and calculation of the axial length (Axl) in any future age, from the age and Axl measured at the time of surgery. METHODS: Retrospective study of children undergoing cataract extraction with IOL implantation between January 2011 and January 2014. We included children with uncomplicated cataract without eye diseases and the age of ten years. Biometric data were obtained with plunge biometer. We carried out the statistical analysis of data and established mathematical formulas to calculate the AGR and Axl. RESTULTS: Were operated on 54 eyes of 33 children, 19 male (57.58%) and 14 female (42.42%). Of the 33 cases analyzed, 12 were unilateral cataracts (36,37%) and 21 were bilateral cataracts (63.63%). In cases of bilateral cataracts was used only the right eye of the data of every child. The sample was divided into 3 groups (unilateral and bilateral cataracts, unilateral cataracts, bilateral cataracts) and for each group was established a mathematical formula to calculate the AGR and Axl. CONCLUSIONS: This study proposes a new way to approach the calculation of IOL, not based on postoperative refractive results but on a daily growth rate (AGR). The generated equations for establishing the daily growth rate at any age and especially to allow predict Axl future from a measured initial Axl. Can not complete with this study that the proposed method is superior to other methods of estimation of eye growth. Comparative studies between them will be needed to assess this accurately
62

Ocorrência de opacidade de cápsula posterior em cães pós-facoemulsificação, com ou sem a utilização de lente intraocular dobrável e efeitos do Nd: Yag Laser /

Conceição, Luciano Fernandes da. January 2014 (has links)
Orientador: José Luiz Laus / Banca: Adriana Morales / Banca: João Antônio Tadeu Pigatto / Banca: Paola Castro Moraes / Banca: Luis Gustavo Gosuen Gonçalves Dias / Resumo: A catarata elenca-se entre as afecções oculares mais freqüentes em cães, sendo a facoemulsificação o método que melhor se adequa à sua terapia. As opacidades de cápsula posterior (OCPs) estão entre as complicações mais comuns e se manifestam em semanas ou meses após a facectomia. Lentes intraoculares (LIOs), empregadas na correção da hipermetropia pós-cirúrgica, são citadas como úteis na prevenção das OCPs, especialmente as acrílicas dobráveis, com bordas truncadas ou quadradas. Entretanto, quando OCPs se estabelecem requerem-se capsulotomias como forma de tratamento. Em pacientes humanos, reconhecem-se os efeitos do Nd:YAG laser como técnica não invasiva e segura frente a tais intercorrências. Para se compararem resultados de olhos de cães que receberam lentes intraoculares acrílicas dobráveis com olhos de cães afácicos, após facoemulsificação, durante um período de 180 dias, utilizaram-se 20 cães de raças diversas, machos ou fêmeas, que variaram de 3 a 7 anos de idade, apresentando catarata juvenil , imatura ou madura (imatura n = 10 , madura n = 10) bilateral. Dois grupos (G1 = com implante de lente intraocular e G2 = sem implante de lente artificial) foram formados aleatoriamente e todos os cães tiveram ambos os olhos operados. Após a cirurgia, os pacientes foram avaliados, semanalmente, quanto a presença ou a ausência de sinéquias, discoria, pressão intraocular, inflamação uveal e presença ou não de opacidade de cápsula posterior durante um período de 180 dias. Aos 60, 90, 120, 150 e 180 dias após a cirurgia, imagens da cápsula posterior foram capturados para avaliação da sua opacidade. Olhos com score 2 ou 3 de opacidade foram submetidos à terapia de capsulotomia pelo Nd:YAG laser. Variáveis categóricas ordinais foram comparadas (G1 X G2) empregando-se o teste de qui-quadrado e o teste exato de Fisher. Variáveis quantitativas foram comparadas empregando-se ANOVA com pós teste de Tukey / Abstract: Cataracts are among the most common eye diseases in dogs, being the phacoemulsification method the one that best suits in their therapy. The posterior capsule opacification (PCOs) are among the most common complications and manifest themselves in weeks or months after cataract surgery. Intraocular lenses (IOLs) used in the correction of postoperative hyperopia, are mentioned as useful in the prevention of PCOs , especially the foldable acrylic ones with truncated or square edges. However, when PCOs are set up, capsulotomies are required as a treatment. In human patients, the effects of the Nd:YAG laser are recognized as a noninvasive and secure technique against such problems. To compare the results of eyes of dogs that received foldable acrylic intraocular lenses with eyes of aphakic dogs, after phacoemulsification, during a period of 180 days it was used 20 dogs of several breeds, male or female , ranging from 3 to 7 years old , with juvenile, immature or mature (n = 10 immature, mature n = 10) bilateral cataracts . Two groups (G1 = with implantation of intraocular lens and G2 = no artificial lens implant) were randomly formed and all dogs had both eyes operated. After the surgery, the patients were weekly evaluated for the presence or absence of synechiae, discoria, intraocular pressure, uveal inflammation and presence or absence of posterior capsule opacification during a period of 180 days. At 60, 90, 120, 150 and 180 days after surgery, the posterior capsule images were captured for evaluation of their opacity. Eyes with score 2 or 3 of opacity were underwent to capsulotomy by Nd:YAG laser. Ordinal categorical variables were compared (G1 X G2) using the chi-square and Fisher's exact test. Quantitative variables were compared using ANOVA with Tukey post test. Synechiae were observed in the same frequency in both groups .G2 showed 30 % more discoria when compared to G1 Intraocular pressure did not differ between the groups. The ... / Doutor
63

Avaliação da opacidade da cápsula posterior, após facoemulsificação e implante de lente intraocular modificada com plasma de flúor ou polietilenoglicol com coelhos /

Sereno, Maria Guadalupe. January 2012 (has links)
Orientador: Cláudia Valéria Seuller Brandão / Coorientador: Antônio Carlos Lotelli Rodrigues / Banca: José Joaquim Titon Ranzani / Banca: Silvana Artioli Schellini / Banca: Georgia Nadalini Rodrigues / Banca: Cláudia Helena Pellizzon / Resumo: A opacidade de cápsula posterior (OCP) é a complicação tardia mais comum após remoção da catarata por facoemulsificação e constitui uma nova barreira à passagem da luz. A modificação superficial das lentes intraoculares (LIOs) e tratamento por plasma vêm sendo estudados, com o intuito de aumentar a biocompatibilidade das mesmas e induzir menor proliferação celular com a posterior manifestação da OCP. O presente estudo teve por objetivo avaliar e comparar a OCP, bem como as variáveis clínico-oftalmológicas após facoemulsificação e implante de lente intraocular (LIO), modificada com plasma de flúor (SF6) ou de polietilenoglicol (PEG), em coelhos. Foram constituídos quatro grupos, de 10 animais cada. Todos os coelhos foram submetidos à facoemulsificação, sendo este o único procedimento no grupo GF; os animais do GL receberam o implante de LIOs hidrofílicas sem tratamento; no GP foram implantadas LIOs tratadas com plasma de flúor, e no GPeg LIOs polimerizadas com plasma de polietilenoglicol. Após o procedimento cirúrgico, foi feita a avaliação macroscópica e semiquantitativa da OCP, opacidade de cápsula anterior (OCA) e fimose capsular, pela lâmpada de fenda, bem como foi mensurada a pressão intraocular (PIO) e analisada espessura corneal e endotélio por microscopia especular. Adicionalmente, foi realizada a fotodocumentação digital por retroiluminação da cápsula posterior foram analisadas quanto à OCP, utilizando-se o software POCOman (Posterior Capsule Opacification Manual), até as doze e 24 semanas do pós-operatório, nos momentos de avaliação precoce e tardia respectivamente. Na avaliação clínica oftalmológica e do endotélio da córnea não houve diferença significativa entre os grupos. A OCP foi menos intensa nos grupos tratados por plasma, na biomicroscopia. O GF apresentou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Intraocular lenses surface modification and plasma treatment are being studied, in order to increase the biocompatibility and induce less cell proliferation with the later manifestation of posterior capsule opacification (PCO). The present study aimed to evaluate and compare the PCO, as well as clinical and ophthalmological variables after phacoemulsification and intraocular lens implantation (IOL), modified with fluoride (SF6) plasma or poly (ethylene) glycol (PEG), in rabbits. Four groups with 10 animals each were constituted. All rabbits were submitted to phacoemulsification, being this the only procedure in GF group; the GL animals received the implant of hydrophilic IOLs; GP received fluoride plasma treated IOLs, and GPeg poly (ethylene glycol) plasma-polymerized IOLs. After the surgical procedure, the PCO macroscopic evaluation was made of the OCP, anterior capsule opacification (OCA) and capsular phimosis by slit-lamp, as well as was measured the intraocular pressure (IOP) and analyzed corneal thickness and endothelium by specular microscopy. Additionally, digital photographs by backlight of posterior capsule were analysed as to the OCP, using the software POCOman (Posterior Capsule Opacification Manual), until the 12 and 24 postoperative weeks in early and late evaluation respectively. In clinical assessing eye cornea and endothelium there was no significant difference between the groups. To slit lamp exam PCO was less intense in the groups treated by plasma. The GF had the highest rates of anterior capsule opacity and capsular phimosis in relation to groups with IOL. POCOman, was not evidenced in effect in reducing the PCO in the group treated by Fluoride in relation to non treated. The implant of IOLs treated with plasma does not promote inflammatory eye signs and endothelial additionally changes, demonstrating... (Complete abstract click electronic access below) / Doutor
64

Avaliação in vitro das características de liberação de indometacina a partir de dispositivos oculares implantáveis

Moura, Renata Kely de Paulo 31 August 2010 (has links)
Made available in DSpace on 2015-05-14T13:00:14Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 1937147 bytes, checksum: c7c7a7218440d8aec73885dba794fe24 (MD5) Previous issue date: 2010-08-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The anatomy and physiology of the eye, together with its protective barriers represent challenges to effective ocular drug delivery systems. The pharmacological treatment of eye diseases had been limited to conventional drug formulations, which are not satisfactory for diseases affecting the posterior segment of the eye. The delivery of therapeutic doses at tissues from the posterior segment in order to minimize adverse systemic and regional effects is the main goal in the treatment of ocular diseases. With this aim, several studies have been conducted to develop new ocular drug delivery systems, such as those involving ocular implants. These implants are prepared using a variety of different polymers that can be either biodegradable or non-biodegradable. Polymers derived from lactic and glycolic acid have revealed to be promising materials for the formulation of ocular implants, mainly due to their biocompatibility and biodegradability. In this study, two different biodegradable indomethacin implants formulated based on a copolymer of lactic/glicolic acid (PLGA 50:50) and D,L-lactic acid (D,L-PLA) were characterized by differential scanning calorimetry (DSC), in vitro release using dissolution apparatus and scleral diffusion (from rabit´s eye) using Franz chambers. The study was done in collaboration with 3T Biopolymers (São Paulo, Brazil) that provided samples of the polymers and implants for analyses. The results of the validation of the HPLC method for indomethacin quantification were within the limits set forth by Brazilian legislation (RE 899, 2003, ANVISA). The results of DSC analysis revealed absence of any evidence of physico-chemical interactions between the drug and polymer. The suppression of the indomethacin melting peak is probably due to changes from the crystalline to the amorphous state of the drug following lyophilization or by dilution effects. Preliminary in vitro release data revealed a triphasic profile for indomethacin release from the PLGA-based implants and a biphasic one for the PLA implants. The implants formulated with PLGA promoted a faster release of indomethacin (103.64%) compared with implants formulated with PLA (49.9%) during the thirty days of the experiment. The release profile of indomethacin was determined by the rate of degradation of polymers, which also determined the scleral diffusion of indomethacin from PLGA and PLA (1.7 x 10-5 cm / s and 0.24 x 10-5 cm / s, respectively). The scleral diffusion experiments using Franz difusion chambers have shown that the rabit sclera is permeable to indomethacin and polarized light microscopy revealed that the structure of the scleral collagen fibers were not significantly altered during the diffusion experiments. The drug-release systems studied were able to release indomethacin in a sustained fashion, serving as a model for the formulation of indomethacin implants that could be used in the future for the treatment of ocular diseases such as the cystoid macular edema. / A anatomia e fisiologia do olho e suas barreiras protetoras representam um desafio para o desenvolvimento de sistemas de transporte de drogas oftálmicas efetivos. O tratamento farmacológico de doenças oculares tem se limitado às formas convencionais de administração que não são satisfatórias para o tratamento de doenças que acometem o segmento posterior do bulbo do olho. O transporte de doses terapêuticas para os tecidos do segmento posterior do olho, que minimize os efeitos colaterais sistêmicos e locais, é o principal objetivo no tratamento de doenças oculares. Visando atingir este objetivo, estudos têm sido feitos no sentido de desenvolver novos sistemas de liberação de fármacos para o olho, entre estes estão os implantes. Esses implantes são preparados a partir de diferentes polímeros, os quais podem ser biodegradáveis ou não biodegradáveis. Os polímeros derivados dos ácidos lático e glicólico têm se revelado bastante promissores devido, principalmente, às suas características de biocompatibilidade e biodegradabilidade. Neste trabalho, dois diferentes implantes de indometacina formulados a partir do copolímero ácido lático / ácido glicólico (PLGA 50:50) e do polímero derivado do ácido D,L-lático (PLA), através de liofilização da mistura polímero-fármaco, foram fornecidos pela empresa 3T Biopolímeros (São Paulo - SP) e avaliados através de DSC, estudos de liberação in vitro usando aparato de dissolução e estudos de difusão através de esclera de coelho utilizando câmaras de Franz. Os resultados da validação do método CLAE para quantificação da indometacina apresentaram-se dentro dos limites estabelecidos pela legislação brasileira (Resolução RE 899, 2003, ANVISA). As análises de DSC mostraram a ausência aparente de interações químicas e físicas entre o fármaco e os polímeros, sendo sugerido que o desaparecimento do pico de fusão da indometacina tenha ocorrido pela amorfização do fármaco durante o processo de liofilização ou pela diluição do fármaco no polímero. Os estudos preliminares de liberação in vitro demonstraram um perfil trifásico para os implantes formulados com PLGA e um perfil bifásico para àqueles formulados com PLA. Os implantes formulados com PLGA promoveram uma liberação mais rápida da indometacina (103,64%) quando comparado com os implantes formulados com PLA (49,9%) durante os trinta dias de experimento. O perfil de liberação da indometacina foi determinado pela velocidade de degradação dos polímeros, que também determinou a difusão escleral da indometacina a partir do PLGA e do PLA (1,7 x 10-5 cm/s e 0,24 x 10-5 cm/s, respectivamente). Os estudos de difusão escleral mostraram que a esclera de coelho é permeável à indometacina e a microscopia de luz polarizada mostrou que a estrutura das fibras colágenas da esclera não foram significativamente alteradas durante o estudo de difusão nas câmaras de Franz. Os sistemas de liberação de fármacos avaliados foram capazes de liberar a indometacina de forma prolongada, servindo como um modelo para formulação de implantes de indometacina que podem ser futuramente utilizados para tratamento de doenças como edema macular cistóide.
65

Estudo comparativo do estresse oxidativo após facoemulsificação experimental com e sem implante de lentes intra-oculares em cães / Comparative study of the oxidative stress following experimental phacoemulsification with and without intraocular lens implantation in dogs

Adriana Lima Teixeira 29 July 2003 (has links)
O tratamento da catarata em cães têm passado por algumas mudanças. A facoemulsificação reduziu o tempo cirúrgico e a necessidade de incisão extensa; o implante de lentes intra-oculares (LIOs) permitiu restabelecer a emetropia após a remoção do cristalino. O processo inflamatório induzido pelas cirurgias intra-oculares leva a um estado de estresse oxidativo, com efeitos deletérios às estruturas oculares. O presente estudo teve como objetivo avaliar comparativamente o estresse oxidativo após facoemulsificação experimental em cães, com e sem implante de LIO. Doze cães (três machos e nove fêmeas), sem raça definida, com peso médio de 15,8kg, foram submetidos à facoemulsificação bilateral, sendo doze olhos sem implante de LIO (Grupo 1) e doze olhos com implante de LIO de polimetilmetacrilato no saco capsular (Grupo 2). Os animais foram medicados nos períodos pré-operatório e pós-operatório com antiinflamatórios, antibióticos e midriáticos. As amostras de humor aquoso (HA) foram obtidas por paracentese de câmara anterior, sob anestesia geral, nos períodos pré-operatório (T0) e pós-operatório com 1 dia (T1), 2 dias (T2), 3 dias (T3), 7 dias (T7) e 14 dias (T14). O estresse oxidativo foi avaliado por meio da determinação quantitativa de proteínas no HA (método de Lowry), avaliação da atividade antioxidante total do HA utilizando o AAPH, cloreto de 2,2'azobis (2-metilamidinopropano) e avaliação da concentração de ácido ascórbico no HA e no plasma (cromatografia líquida de alta eficiência). Os resultados foram submetidos à análise estatística, utilizando-se o teste t de Student, quando as variáveis apresentaram distribuição normal, e pelo teste de Wilcoxon, quando não houve distribuição normal. Os níveis de proteína total no HA aumentaram nos dois grupos, sendo de forma mais acentuada no Grupo 2 em todos os tempos pós-operatórios: T1 (p= 0,004), T2 (p= 0,002), T3 (p= 0,004), T7 (p= 0,003) e T14 (p= 0,009). A atividade antioxidante total do HA apresentou uma diminuição nos dois grupos, mais acentuada, entretanto, no Grupo 2, com diferença estatisticamente significante nos tempos T1 (p= 0,013), T2 (p= 0,016), T3 (p= 0,002) e T14 (p= 0,033). No tempo T7 (p= 0,155) essa diferença não foi observada. A concentração de ácido ascórbico no HA apresentou uma diminuição marcante no primeiro dia do pós-operatório, seguida por uma recuperação progressiva nos dois grupos. O Grupo 2 mostrou resultados mais baixos, com diferença estatisticamente significante nos tempos T1 (p= 0,003), T3 (p= 0,015), T7 (p= 0,004) e T14 (p= 0,007), exceto em T2 (p= 0,051), quando não houve diferença. A concentração de ácido ascórbico no plasma não variou em função dos procedimentos. A comparação entre os procedimentos sugere que o implante de LIO contribui para a condição de estresse oxidativo. / The cataract treatment in dogs has undergone some changes. Phacoemulsification has reduced the surgical time of cataract extraction and the need of large incision. Intraocular lens (IOL) implantation has allowed emetropic vision recovery. The inflammatory process induced by intraocular surgery leads to an oxidative stress, with ocular structures damage. The purpose of this study was to comparatively evaluate the oxidative stress following phacoemulsification in dogs with and without IOL implantation. Twelve dogs, three male and nine female, mixed breed, with an average weight of 15.8kg were submitted to bilateral phacoemulsification, being twelve eyes without IOL implantation (Group 1) and twelve eyes with polymethylmethacrylate IOL in the capsular bag (Group 2). In the pre-operative and post-operative periods, the medication consisted of anti-inflammatories, antibiotics and mydriatics. Aqueous humor (AH) samples were taken by anterior chamber paracentesis, under general anesthesia in the pre-operative (T0) and post-operative periods after 1 (T1), 2 (T2), 3 (T3), 7 (T7) and 14 (T14) days of the surgery. The oxidative stress was evaluated by quantitative protein levels in the AH (Lowry’s method), total antioxidant activity in the AH using 2,2’ azobis (2-methylpropionamidine) dihydrochloride (AAPH) and ascorbic acid concentration in the AH and plasma (high performance liquid chromatography). Results were submitted to statistical analysis using the t-student test when the variables had a normal distribution and Wilcoxon test when they did not. Aqueous humor total protein levels increased in both groups, more intensively in Group 2 in all post-operative periods: T1 (p= 0.004), T2 (p= 0.002), T3 (p= 0.004), T7 (p= 0.003) and T14 (p= 0.009). Total antioxidant activity in the AH decreased in both groups; however, it was more impressive in Group 2, with statistical significant difference in T1 (p= 0.013), T2 (p= 0.016), T3 (p= 0.002) e T14 (p= 0.033). In T7 (p= 0.155), this difference was not observed. Ascorbic acid concentration in the AH presented a remarkably decrease in the first post-operative day, then started to recover progressively in the two groups. Group 2 showed lower results with statistically significant differences in T1 (p= 0.003); T3 (p= 0.015); T7 (p= 0.004) and T14 (p= 0.007), except in T2 (p= 0.051) when there was no difference. Ascorbic acid concentration in plasma did not vary as a result of the procedures. The comparison between procedures suggests that IOL implantation contributes to an oxidative stress condition.
66

Sistema de medidas de áreas de úlceras de córnea e acompanhamento de suas evoluções para ser utilizado em hospitais / System for measuring corneal ulcers areas and their evolution monitoring to be used in hospitals

Caio Chiaradia 02 October 1998 (has links)
Foi desenvolvido um sistema inédito para diagnóstico e acompanhamento de Doenças Oculares Externas, particularmente de úlceras de córnea e que foi implementado num Hospital-Escola para uso diário. As úlceras de córnea, até então, eram avaliadas de forma subjetiva e qualitativa, estimando-se a extensão da área afetada. O indicativo de evolução do quadro clínico é basicamente a alteração da área afetada. Com o intuito de se poder avaliar a evolução desta patologia de forma quantitativa e padronizada, foi desenvolvido o presente sistema. O sistema consistiu em acoplar a uma Lâmpada de Fenda (biomicroscópio ocular) um divisor de feixes e um sistema ótico, no caminho ótico onde os feixes da Lâmpada de Fenda são paralelos, de forma que a imagem proporcionada nas oculares da Lâmpada de Fenda é simultaneamente proporcionada num detector do tipo CCD. Esta câmera CCD foi acoplada a um micro computador do tipo PC, via uma interface comercial, e as imagens são disponibilizadas num monitor. Um software dedicado foi desenvolvido e possui as seguintes funções e características: reconhecimento automático e medidas das áreas de ulceração, opcionalmente, medidas interativas de áreas quaisquer, medidas lineares interativas de comprimentos quaisquer e um amplo banco de dados dedicado a este setor da Oftalmologia. Ainda, todos os comandos podem ser realizados através do teclado ou do mouse, particularmente o de capturar imagem também pode ser acionado através de um pedal desenvolvido especialmente para o sistema. O sistema apresentou uma precisão de 5% (o método convencional, para medidas de úlceras perfeitamente elípticas proporcionava uma precisão de no máximo 13%). O protótipo do sistema está em uso no Hospital das Clínicas de Ribeirão Preto (ambulatório de Oftalmologia, setor de Doenças Oculares Externas), tem demonstrado excelente desempenho e estudos clínicos, agora proporcionados pela automação do sistema, começam a ser realizados / A system for diagnostic and follow up of External Ocular Diseases has been developed, particularly for Corneal Ulcers, and has been implemented in a Hospital-School for daily use. The corneal ulcers, until then, have been evaluated in a subjective and qualitative way, just by estimating the affected area. Its clinical evolution is indicated by the increasing/decreasing of the affected area. In order to evaluate quantitatively and standardize the evolution of this pathology we have developed the present system. The system consisted in attaching to a Slit Lamp (ocular biomicroscope) a beam splitter in the parallel rays optical path and an optical system, in order to provide simultaneously the ocular images to the Slit Lamp ocular lenses and to a CCD camera. The camera has been attached to a PC, via a commercial frame grabber and the images are displayed in a monitor. A dedicated software has been developed and it has the following functions and features: corneal ulcers self recognizing and area measurements, optional interactive area and extension measurement of any image and a data bank dedicated for this sector of the Ophthalmology. Also all the commands are available for keyboard or mouse clicking. Particularly, the image capturing command can also be turned ON/OFF by clicking a pedal, which was specially developed for the system. The precision of the measurements of the system is 5% (the conventional method, for perfect elliptical ulcer areas provides a maximum precision of 13%). The system\'s prototype is being used in the Hospital das Clínicas de Ribeirão Preto and it has presented excellent performance. Clinical studies are now being able to be done due to the automation of the clinical evaluations
67

Análise de emoções em expressões faciais: veracidade das emoções e rastreio ocular

Busin, Yuri 06 February 2014 (has links)
Made available in DSpace on 2016-03-15T19:40:16Z (GMT). No. of bitstreams: 1 Yuri Busin.pdf: 1414328 bytes, checksum: b9fec72afdd3508a27b151307594f12c (MD5) Previous issue date: 2014-02-06 / Emotions consist in reactions to significant actions on individuals, more specifically, the responses that involve an affective experience, and may be expressed verbally or not. The human face can express many emotions enabling the exchange of information about affective states, facilitating interaction between individuals. Not all facial expressions are genuine, because in social interactions exist lies and deceptions that can range from altruistic and motives to lie for fear of punishment. Studies show brain regions associated with identifying and perception of each emotion and as cerebral laterality may influence the recognition and expression. The left side of the face has been identified as the most informative to identify emotions, revealing the existence of asymmetry in facial expressions of emotions identification. The objective of the study is to evaluate the pattern of eye movements in tasks of trial expressions of real and falsified emotions. Participated 33 subjects, who was instructed to watch and judge the 96 movies, divided in 2 bateries, each containing 48 movies with true and false facial emotion expressions. All the movies showed more the left area of the face and were edited to have a mirror efect. The movies were presented on a computer with Eye- Tracking device for tracking eye movements. The expressions presented were: happiness, fear and sadness. Participants indicated whether the expression view was true or not. The results indicate that the left hemisphere of the brain is more involved in judging the emotions through the face, as well as being faster, and genuine emotions got a better hit rate. / As emoções consistem em reações a ações significativas nos indivíduos, mais especificamente, a respostas que envolvem uma experiência afetiva, podendo ser expressadas verbalmente ou não. A face humana pode expressar muitas emoções possibilitando a troca de informações sobre os estados afetivos, facilitando a interação entre indivíduos. Nem todas as expressões faciais são genuínas, pois nas interações sociais existem mentiras e dissimulações que podem variar desde motivações altruístas até mentiras por medo de punição. Estudos mostram as regiões cerebrais relacionadas com a identificação e sentimento de cada emoção, e como a lateralidade cerebral pode influenciar no reconhecimento e expressão das mesmas. Assim, o lado esquerdo do rosto tem sido identificado como mais informativo para identificar emoções, revelando a existência de assimetria facial na identificação das expressões de emoções. Objetivo do estudo é avaliar o padrão dos movimentos oculares em tarefas de julgamento de expressões de emoções reais e falseadas. Participaram do estudo 33 sujeitos, os quais serão instruídos a assistir grupos de vídeos, cada um contendo 48 vídeos com expressões falseadas e verdadeiras. Os vídeos apresentam a área esquerda do rosto maior. Estes vídeos foram editados de forma que apresentem as emoções espelhadamente e normais. Todos os vídeos foram apresentados em um computador com equipamento de Eye-Tracking para o rastreamento dos movimentos oculares. As expressões apresentadas foram: Alegria, Medo e Tristeza. Os participantes indicaram se a expressão vista era ou não verdadeira. Os resultados apontam que o campo visual direito é mais utilizado e mais rápidos para julgamento das emoções, sendo assim há uma maior ativação do hemisfério esquerdo cerebral. O julgamento de emoções genuínas obteve um melhor índice de acertos.
68

Movimentos oculares na leitura de palavras: modulação por estimulação transcraniana por corrente contínua

Rosa, Alexandre Tadeu Faé 22 January 2009 (has links)
Made available in DSpace on 2016-03-15T19:40:37Z (GMT). No. of bitstreams: 1 Alexandre Tadeu Fae Rosa.pdf: 3127122 bytes, checksum: 7cc2fee5f67c75093575447bd7628184 (MD5) Previous issue date: 2009-01-22 / Fundo Mackenzie de Pesquisa / Transcranial Direct Current Stimulation (tDCS) is a technique which is able to modulate cortical excitability in a safe, painless and non-invasive way. The effects of increasing and reduction of the excitability obtained after application of tDCS depend on the polarity which has been used (anodal or cathodal). This dissertation aims at investigating the effects of tDCS on the preparation of saccadic movements in reading. In the experiment, healthy volunteers performed a word-reading task after being exposed to anodal, cathodal or sham tDCS over the right frontal eye field (FEF). The results show that anodal tDCS applied over the right FEF has a delay effect on the performance of the subjects while making the first saccadic movement during reading. Besides, the results show a significant increase of the condition of cathodal stimulation when compared to sham and anodal stimulation related to time in which the subject looks at a fixation mark at the left side after the words appear on the screen. Also, concerning the average reading time of the whole set of words, there was not any significant difference on the main effects or interaction. / A estimulação transcraniana por corrente contínua (ETCC) é uma técnica capaz de modular a excitabilidade cortical de maneira segura, indolor e não-invasiva. Os efeitos de aumento ou diminuição da excitabilidade obtidos após a aplicação da ETCC dependem da polaridade utilizada (anódica ou catódica). Esta dissertação tem como objetivo investigar os efeitos produzidos pela ETCC na preparação de movimentos sacádicos durante a leitura. No experimento realizado, voluntários saudáveis realizaram uma tarefa de leitura de palavras após terem recebido ETCC anódica, catódica ou placebo em campo visual frontal (CVF) direito. Os resultados mostram que a ETCC catódica em CVF direito piora o desempenho dos sujeitos na realização do primeiro movimento sacádico durante a leitura. Além disso, os resultados revelaram aumento significativo da condição de estimulação catódica em comparação com o placebo e da estimulação catódica em comparação com a anódica com relação ao tempo em que o sujeito fixa o olhar no ponto de referência à esquerda depois do aparecimento dos itens a serem lidos. Ainda, com relação ao tempo médio de leitura de todo o conjunto de palavras, não houve nenhuma diferença significativa para os efeitos principais ou interação.
69

Análise de medidas fisiológicas e comportamentais durante a leitura de textos por disléxicos e bons leitores

Barbosa, Anna Carolina Cassiano 22 January 2013 (has links)
Made available in DSpace on 2016-03-15T19:41:19Z (GMT). No. of bitstreams: 1 Anna Carolina Cassiano Brabosa.pdf: 1148993 bytes, checksum: a240fc0effdaa5732859d8fabc86f715 (MD5) Previous issue date: 2013-01-22 / Fundo Mackenzie de Pesquisa / The developmental dyslexia is a learning disorder that includes behavioral and cognitive disorders such as slow reading and reversals errors of letters and syllables. The analysis of physiological measures during reading can help to understand the deficits present by dyslexics. The main physiological measures related to visual analysis of read items include: patterns of eye movements and pupil diameter variations. This study aims to analyze behavioral and physiological measures of good readers and dyslexics during reading of texts. The study included 16 children, 8 of whom were dyslexic and 8 good readers, with an average age of 10.71 years (sd = 1.799) and 10.57 years (sd= 1,761) respectively. The subjects read four different texts on a computer screen with equipment for analyzing eye movements. The results revealed that dyslexics presented worse than good readers on tests of reading, spelling and phonological awareness. Thus dyslexics have difficulties in the rapid identification of words, confusions committed by visual and auditory similarity, and demonstrate losses in phonological awareness. Additionally, took longer to complete tasks. Analysis of physiological measurements reveal the average duration of fixations was greater for dyslexics. Analysis of pupillary variance indicates that good readers showed no change in pupil diameter in four texts but dyslexics presented pupil contraction in Text 1. / A dislexia do desenvolvimento é um distúrbio de aprendizagem que abrange alterações comportamentais e cognitivas tais como leitura lenta e com erros de inversões de letras e sílabas. A análise de medidas fisiológicas durante a leitura pode auxiliar na compreensão dos déficits apresentados por disléxicos. Dentre as principais medidas fisiológicas relacionadas com a análise visual dos itens lidos destacam-se padrões de movimentos oculares e variações do diâmetro pupilar. O presente trabalho tem como objetivo analisar medidas comportamentais e fisiológicas de disléxicos e bons leitores durante a leitura de textos. Participaram do estudo 16 crianças, sendo 8 disléxicos e 8 bons leitores, com idade média de 10,71 anos (dp=1,799) e 10,57 anos (dp= 1,761) respectivamente. Os sujeitos leram 4 textos diferentes na tela de um computador com equipamento de análise dos movimentos oculares. Os resultados revelaram que disléxicos apresentaram desempenho inferior aos bons leitores nas provas de leitura, escrita e consciência fonológica. Assim, disléxicos apresentam dificuldades na identificação rápida de palavras, cometeram confusões por semelhança visual e auditiva, e demonstram prejuízos em consciência fonológica. Além disso, levaram mais tempo para executar as tarefas. Análises das medidas fisiológicas revelam que a duração média das fixações foi maior para os disléxicos. Análise da variação pupilométrica indica que bons leitores não apresentaram variação no diâmetro da pupila nos 4 textos, mas os disléxicos apresentaram contração pupilar no Texto 1.
70

Efeito da indução de humor no desempenho em teste de inteligência fluida: estratégias cognitivas e padrões de movimentos oculares

Laurence, Paulo Guirro 24 May 2018 (has links)
Submitted by Jaqueline Duarte (1157279@mackenzie.br) on 2018-08-20T17:08:05Z No. of bitstreams: 1 Paulo Guirro Laurence.pdf: 3027607 bytes, checksum: c2e0bcaf60a80b2ede7fbe781307c908 (MD5) / Approved for entry into archive by Giovanna Brasil (1154060@mackenzie.br) on 2018-08-27T19:28:11Z (GMT) No. of bitstreams: 1 Paulo Guirro Laurence.pdf: 3027607 bytes, checksum: c2e0bcaf60a80b2ede7fbe781307c908 (MD5) / Made available in DSpace on 2018-08-27T19:28:11Z (GMT). No. of bitstreams: 1 Paulo Guirro Laurence.pdf: 3027607 bytes, checksum: c2e0bcaf60a80b2ede7fbe781307c908 (MD5) Previous issue date: 2018-05-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Mood induction and emotional states tasks are used to verify the effect of emotions on cognitive performance. Thus, emotions modulate various cognitive abilities, such as attention, working memory and decision making. Although such skills are related to fluid intelligence, studies analyzing the effects of positive or negative valence emotions on this type of intelligence are rare. The aim of the study was to analyze the effects of mood induction with positive or negative valence on fluid intelligence performance. 161 young and adults (100 women) were divided into three groups: mood induction with negative valence, mood induction with positive valence and induction of neutral emotional valence. Initially instruments were applied to assess anxiety, depression, emotional competence, intelligence, mood and salivary cortisol. Participants then watched a video of specific emotional induction related to their experimental group and responded to the mood scale again. After that, they performed on a computer with eye movement recording equipment another intelligence test (WMT-2) composed of items created according to three types of logical reasoning. In order to verify the effect of mood induction videos, a second collection of salivary cortisol was done 30 minutes after the end of the video in a part of the sample. Results show that the 3 groups did not differ in relation to the level of anxiety, depression, emotional competence, intelligence and humor at the beginning of the procedure. However, after induction, the negative induction group had higher levels of anxiety and lower motivation. No significant differences were observed between the three groups in the percentage of items' correctness and time to perform the intelligence test. However, the reverse efficiency index, evaluated by the time of the test divided by the percentage of correct answers, was better for the positive and negative induction groups than the neutral group in one of the types of rule tokens. Analysis of the ocular movement register indicates differences between the positive induction group and the neutral group in the visual exploration pattern of the test boards. Women in the positive induction group presented more correct answers and a better efficiency index than the women in the other two groups for a logical reasoning. In addition, women in the negative induction group also had a better efficiency index than the neutral group in this type of logical reasoning. The neutral induction women group performed worse than the other two female groups in the visual exploration pattern of the test boards. Thus, the positive valence humor induction procedure influenced the efficiency in solving a type of logical reasoning, as well as in the visual exploration of the test boards. Lastly, negative correlations were found between salivary cortisol levels after the induction of mood with the mean time in WMT-2, with emotional competence and with the inverted efficiency index for one of the types of logical reasoning / Tarefas de indução de humor e de estados emocionais são usadas para verificar o efeito das emoções no desempenho cognitivo. Assim, as emoções modulam diversas habilidades cognitivas, tais como a atenção, a memória de trabalho e tomada de decisão. Embora tais habilidades estejam relacionadas com inteligência fluida, são raros os estudos que analisam os efeitos de emoções de valência positivas ou negativas nesse tipo de inteligência. O estudo teve por objetivo analisar os efeitos da indução de humor com valência positiva ou negativa no desempenho em teste de inteligência fluida. Participaram 161 jovens e adultos (100 mulheres) divididos em três grupos: indução de humor com valência negativa, indução de humor com valência positiva e indução de valência emocional neutra. Inicialmente foram aplicados instrumentos para avaliação de ansiedade, depressão, competência emocional, inteligência, humor e cortisol salivar. Em seguida, os participantes assistiam um vídeo de indução emocional específico ao seu grupo experimental e respondiam a escala de humor novamente. Após isso, realizavam em um computador com equipamento de registro de movimentos oculares outro teste de inteligência (WMT-2), composto por itens criados em função de três tipos de raciocínio lógico. A fim de verificar o efeito dos vídeos de indução de humor, uma segunda coleta do cortisol salivar foi feita 30 minutos após o final do vídeo, em uma parte da amostra. Resultados mostram que os 3 grupos não diferiram em relação ao nível de ansiedade, depressão, competência emocional, inteligência e humor no início do procedimento. No entanto, após a indução, o grupo de indução negativa apresentou maiores níveis de ansiedade e menores de motivação. Não foram observadas diferenças significativas entre os três grupos na porcentagem de acertos dos itens e tempo para realização do teste de inteligência. No entanto, a pontuação de eficiência inversa, avaliado pelo tempo de realização do teste dividido pela porcentagem de acertos, foi melhor para os grupos de indução positiva e negativa do que o grupo neutro em um dos tipos de raciocínio lógico. Análise do registro dos movimentos oculares indicam diferenças entre o grupo de indução positiva com o grupo neutro no padrão de exploração visual das pranchas do teste. Mulheres do grupo de indução positiva apresentaram mais acertos e melhor índice de eficiência que as mulheres dos outros dois grupos para um tipo de raciocínio lógico. Além disso, as mulheres do grupo de indução negativa também apresentaram melhor índice de eficiência que o grupo neutro nesse tipo de raciocínio lógico. O grupo de mulheres da indução neutra teve desempenho pior que as mulheres dos outros dois grupos na exploração visual das pranchas do teste. Dessa forma, o procedimento de indução de humor de valência positiva influenciou a eficiência na resolução de um tipo de raciocínio lógico, bem como na exploração visual das pranchas do teste. Por fim, foram encontradas correlações negativas entre os níveis de cortisol salivar após a indução de humor com o tempo médio na realização do WMT-2, com a competência emocional e com a pontuação de eficiência inversa para um dos tipos de raciocínio lógico.

Page generated in 0.0498 seconds