• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 148
  • 12
  • 9
  • 9
  • 9
  • 9
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 161
  • 87
  • 51
  • 40
  • 36
  • 26
  • 26
  • 22
  • 20
  • 20
  • 20
  • 18
  • 17
  • 17
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Determinación de la contaminación bacteriana por aerosoles según localización y tiempo en los ambientes de la clínica docente de la UPC

Rojas Infante, Olenka 08 February 2017 (has links)
Objetivo: Determinar los microorganismos bacterianos presentes en aerosoles originados por instrumental rotatorio según localización y tiempo en los ambientes de la Clínica Docente de la UPC. Materiales y Métodos: Se trabajó con un total de 90 placas de agar sangre en tres grupos de 30 placas cada uno. El primer grupo estuvo conformado por 30 placas control que fueron expuestas antes de la apertura del turno clínico y sin contacto con pacientes. El segundo grupo también estuvo conformado por 30 placas que se expusieron a los aerosoles durante quince minutos. Se utilizaron 2 placas por cada unidad dental, ubicadas en dos sitios diferentes. Una placa se colocó en el lavamanos y la otra sobre la pechera del paciente. El tercer grupo de placas fueron expuestas bajo el mismo protocolo, pero durante 120 minutos. Posteriormente, se realizó el recuento de Unidades Formadoras de Colonias (UFC), tinción Gram y pruebas de identificación, con el objetivo de identificar los microorganismos de la cavidad Oral. Resultados: La mayoría de bacterias encontradas son Gram positivas, pertenecientes a Stafiloccoccus spp y Streptococcus spp. Conclusiones: Existe mayor contaminación bacteriana cerca de un instrumento rotatorio y a mayor tiempo de su uso. / Objective: Determine the bacterial microorganisms present in sprays originated by dental handpieces according to it´s location and time spent on Clinica Docente de la UPC´s environment. Materials and methods: A total of 90 blood agar plates were used in three groups of 30 plates each. The first group consisted of 30 control plates that were exposed before the opening of the clinical shift and without contact with patients. The second group also consisted of 30 plaques that were exposed to the aerosols for fifteen minutes. Two plates were used for each dental unit, located in two different sites. One plaque was placed in the lavatory and the other on the patient's breast. The third group of plaques were exposed under the same protocol, but for 120 minutes. Subsequently, counts of Colony Forming Units (UFC), Gram staining and identification tests were performed, with the objective of identifying the genus of microorganisms in the oral cavity. Results: Most bacteria found are Gram positive belonging to Staphylococcus spp and Streptococcus spp. Conclusions: There is more bacterial contamination near a rotating instrument and a longer time of its use. / Tesis
42

Análise dos níveis de pressão sonora produzidos pelos equipamentos odontológicos e sua relação com a ocorrência de alterações auditivas em cirurgiões-dentistas

Januário, Ana Cláudia January 2000 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção. / Made available in DSpace on 2013-07-15T21:36:03Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T16:01:57Z : No. of bitstreams: 1 185218.pdf: 36690667 bytes, checksum: afba2aae57488aa92adcf81d502ceb62 (MD5) / Provavelmente a grande maioria, se não todas, as pessoas já se submeteu à experiência de aguardar atendimento odontológico na sala de espera de um consultório dentário. Ao ouvir o som produzido pelos equipamentos dentários sentem um certo desconforto e por que não dizer medo, não do barulho em si, mas pela estreita relação deste com a sensação dolorosa. O que as pessoas não se dão conta, incluindo os próprios cirurgiões - dentistas é do perigo que o temido "barulhinho das brocas dentárias", representa à integridade física das pessoas que a ele se expõem. A presente pesquisa revela dados importantíssimos, que indicam a presença de alterações irreparáveis à saúde de cirurgiões - dentistas, principalmente, ao sentido da audição, que levam a crer na relação destes, com a exposição aos elevados níveis de pressão sonora- NPS dB(A) produzidos pelos equipamentos odontológicos. O estudo demonstra que, os níveis de ruído produzido pelos equipamentos odontológicos observados sugerem, um ambiente de risco aos cirurgiões dentistas, onde 16% da população atingida apresentou alguma alteração auditiva permanente e 64% dos examinados apresentaram alteração significativa do limiar auditivo no exame realizado sem repouso acústico, ou melhor, após a jornada de trabalho e apenas 20 % dos dentistas não apresentaram modificação de limiar auditivo após a exposição ao ruído dos equipamentos dentários.
43

Avaliação da eficácia da estufa de Pasteur como equipamento esterilizante em consultórios odontológicos do Distrito Central de Goiânia-GO / Evaluation of effectiveness of dry heat as a sterilizing equipment in dental offices from Central District of Goiânia-GO

TAVARES, Solange do Socorro Fonseca 20 September 2005 (has links)
Made available in DSpace on 2014-07-29T15:04:37Z (GMT). No. of bitstreams: 1 dissertacao solange.pdf: 308864 bytes, checksum: 6d208eb9890e9b29544895e6ba02d4ec (MD5) Previous issue date: 2005-09-20 / The aim of this analytical study was to evaluate the effectiveness of dry heat as a sterilizing equipment in dental offices with regard to: the packing of the load, the time and temperature used, the use of biological and chemical monitoring in the sterilization control as well as the performing of preventive maintenance. The data were obtained from 101 dental offices in the Central District of Goiânia, Goiás, Brazil, through the following procedures: use of check-list and interview; checking the temperature of the dry heat and performing the biological monitoring.The results showed that most of the people in charge of the article sterilization in dry heat performed it without the folowing proceedings proclaimed by Health Ministry: adequate package disposal, monitoring by accessory thermometer, performance of indicated cycles and accomplishment of preventive maintenance. The results also showed that the most significant intervening factors for the quality of sterilization were both the no accomplishment of chamber monitoring by accessory thermometer and time/temperature relationship indicated for sterilization cycle. In addition, dry heat was not effective for 46 (45,5%) dental offfices investigated, confirming other studies which concluded that dry heat is an equipment susceptible to sterilization failure and its effectiveness is close related to the accomplishment of the proclaimed loading and sterilization which depend on human action. / Este estudo analítico objetivou avaliar a eficácia da estufa de Pasteur como equipamento esterilizante em consultórios odontológicos com relação: ao acondicionamento da carga, tempo/temperatura utilizados, uso de testes químicos e monitoramento biológico no controle da esterilização e à prática de manutenção preventiva. Os dados foram coletados em 101 consultórios odontológicos no Distrito Central de Goiânia-Goiás-Brasil, por meio dos seguintes procedimentos: uso de check-list e entrevista, aferição da temperatura da estufa de Pasteur e realização de teste com indicador biológico. Os resultados demonstraram que a maioria dos responsáveis pela esterilização dos artigos em estufa, realizam-na sem a padronização das seguintes condutas preconizadas pelo Ministério da Saúde (MS): disposição correta dos pacotes, monitoramento por termômetro acessório, realização de ciclos indicados e de manutenção preventiva. Revelaram, também, que os fatores intervenientes com maior significância à qualidade da esterilização foram: não-realização de monitoramento das câmaras por termômetro acessório e as relações tempo/temperatura indicadas para o ciclo de esterilização. Além disso, a estufa de Pasteur não foi eficaz para 46 (45,5%) consultórios odontológicos pesquisados, confirmando, outros estudos, que este equipamento é suscetível ao insucesso da esterilização e sua eficácia está intimamente relacionada ao cumprimento dos parâmetros preconizados, os quais dependem da ação humana.
44

Preparo e avaliação de compósitos contendo nova matriz inorgânica monomodal submicrométrica / Preparation and evaluation of new inorganic matrix composites containing submicron monomodal

Valente, Lisia Lorea 17 May 2012 (has links)
Made available in DSpace on 2014-08-20T14:30:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-05-17 / In this study dental composites containing a novel monomodal inorganic matrix based on submicron Ba-Al-Si glass particles (NanoFine NF180, Schott) were prepared and evaluated. Composites with particles of similar composition but micron-sized (UltraFine UF1.0, Schott) served as a reference. The study was carried out in two phases: (i) characterization of the inorganic particles, involving x-ray microanalysis and granulometry; (ii) preparation and characterization of micron and submicron composites involving analysis of the morphology of the composites and measurements of radiopacity, degree of C=C conversion, hardness, flexural strength and modulus, work-of-fracture, surface roughness and gloss before and after toothbrushing abrasion and compressive creep. The composites were formulated from the same co-monomer based on Bis-GMA, Bis-EMA8, UDMA and TEGDMA at a 7:7:5:1 (w/w) ratio, with photoinitiators added. A mass of 75% of micron and 78% of submicron particles were incorporated based on pilot studies. Quantitative data restricted to direct comparisons between the composites were analyzed using t-tests. Roughness and gloss data for the comparison between the composites before and after toothbrushing were submitted to Repeated Measures Analysis of Variance and Student-Newman-Keuls test (5%). Both inorganic systems showed narrow grain size range (175±30 and 1000±200nm), with differences restricted to the size and specific area of the particles, which determined differences in the amount of silane used (13% for submicron and 3.2% for micron particles). Particles from both systems were homogeneously dispersed in the resin phase, although the submicron particles occupied larger area of the material s surface. The composites showed statistically similar results for radiopacity, flexural strength, work-of-fracture, and creep. The submicron composite had significantly higher hardness than the micron composite, whereas significantly lower flexural modulus and C=C conversion. No significant differences in roughness between the composites were observed before toothbrushing, while the submicron composite showed significantly higher gloss. The abrasion increased significantly the roughness and reduced the gloss of both materials. Surface roughness was still similar and the gloss of the submicron composite significantly higher after toothbrushing. In conclusion, the monomodal submicron glass filler system tested showed potential for application in the development of restorative dental composites, especially because of the esthetic properties compared with the micron system / Neste estudo, foram preparados e avaliados compósitos odontológicos contendo nova matriz inorgânica monomodal baseada em partículas de vidro de Ba-Al-Si (NanoFine NF180, Schott) de tamanho submicrométrico. Compósitos contendo partículas de composição similar, porém tamanho micrométrico (UltraFine UF1.0, Schott), foram testados como referência. O estudo se desenvolveu em duas fases: (i) caracterização de partículas inorgânicas, envolvendo microanálise de raios-x e granulometria; (ii) obtenção e caracterização de compósitos micro e submicrométricos envolvendo análise da morfologia dos compósitos preparados e determinação da radiopacidade, grau de conversão de C=C, dureza, resistência e módulo de flexão, trabalho de fratura, rugosidade e brilho da superfície antes e após desgaste por abrasão e escoamento compressivo (creep). Os compósitos foram formulados a partir do mesmo co-monômero baseado em Bis-GMA, Bis-EMA8, UDMA e TEGDMA, na razão 7:7:5:1 (m/m), ao qual fotoiniciadores foram adicionados. Foi acrescentada massa de 75% do sistema micrométrico e 78% do submicrométrico, com base em estudos-piloto. Os dados quantitativos restritos à comparação direta entre os compósitos foram analisados utilizando testes-t. Os dados de rugosidade e brilho na comparação dos compósitos antes e após a escovação foram submetidos à Análise de Variância para Medidas Repetidas e teste de Student-Newman-Keuls (5%). Ambos sistemas inorgânicos apresentaram estreita faixa do tamanho de grão (175±30 e 1000±200nm), com diferenças entre as partículas restritas ao tamanho e área específica, o que determinou diferença na quantidade de silano utilizada (13% para submicrométricas e 3,2% para micrométricas). As partículas de ambos sistemas foram dispersas de forma homogênea na matriz resinosa, embora as submicrométricas ocuparam maior área da superfície do material. Os compósitos apresentaram resultados estatisticamente similares para radiopacidade, resistência à flexão, trabalho de fratura e escoamento compressivo. O compósito submicrométrico apresentou dureza significativamente superior ao material micrométrico, enquanto módulo de elasticidade e grau de conversão foram significativamente menores. Não foi observada diferença significativa na rugosidade entre os compósitos antes da escovação, enquanto o compósito submicrométrico mostrou brilho significativamente maior. A abrasão aumentou significativamente a rugosidade e reduziu significativamente o brilho de ambos materiais. A rugosidade continuou estatisticamente similar e o brilho do compósito submicrométrico significativamente maior após a abrasão. Em conclusão, o sistema monomodal submicrométrico de carga de vidro testado apresentou potencial de utilização no desenvolvimento de compósitos restauradores odontológicos, especialmente em função de suas propriedades estéticas comparadas ao sistema micrométrico
45

Eficácia de enxaguatórios bucais pré-procedimento na redução de microrganismos no aerossol: uma revisão sistemática / Efficacy of mouthwashes pre-procedural in the reduction of microorganisms in the aerosol: a systematic review

Marui, Vanessa Costa 07 December 2018 (has links)
Esta revisão teve como objetivo avaliar a eficácia do uso de enxaguatórios bucais pré-procedimento na redução do número de microrganismos disseminados pelo aerossol gerado pelos procedimentos odontológicos. Apenas ensaios clínicos randomizados (ECRs) foram incluídos. As bases de dados MEDLINE (PubMed), Google Acadêmico e LILACS foram pesquisadas para busca de artigos publicados até março de 2018. Foi realizada meta-análise de efeitos aleatórios da redução de unidades formadoras de colônia (UFCs) isoladas após realização de procedimentos odontológicos que geram aerossol. Dos 725 artigos potencialmente relevantes, 12 ECRs que estudaram a eficácia da clorexidina, óleos essenciais, cloreto de cetilpiridínio e produtos fitoterápicos foram incluídos. Todos os estudos mostraram que o enxaguatório bucal pré-procedimento promoveu redução significativa no número de UFCs. A Meta-análise mostrou que enxaguatórios bucais com óleos essenciais promoveram redução percentual média de 73,9% no número de UFCs. Nenhum dos estudos incluídos apresentou baixo risco de viés. Os resultados desta revisão permitem concluir que a realização de enxágue pré-procedimento reduz significativamente o número de microrganismos no aerossol. / This review aimed to evaluate the efficacy of pre-procedural mouthrinses in reducing the number of microorganisms disseminated by the aerosol generated by dental procedures when compared to placebo or no mouthrinse. Only randomized clinical trials (RCTs) were included. MEDLINE (PubMed), Google Scholar and LILACS databases were searched for articles published until March 2018. Random effects meta-analysis was performed for reduction of the number of colony forming units (CFU) disseminated in the dental office by the aerosol. Of 725 potentially relevant articles, 12 RCTs that studied the efficacy of chlorhexidine, essential oils, cetylpyridinium chloride and herbal products were included. All studies have shown that pre-procedural mouthwashes promoted significant reduction in the number of CFUs. Meta-analysis showed that mouthwashes with essential oils promoted mean percentage reduction of 73.9% in the number of CFUs. None of the included studies presented low risk of bias. In conclusion, pre-procedural mouthwashes significantly reduce the number of microorganisms in the aerosol.
46

Móvil Dent / Mobile Dent

Ferreyros Avila, Alvaro Marcell, Landa Ochoa, Raúl Martín, Sotil Montenegro, Janeth Marleny 12 December 2018 (has links)
El presente proyecto está referido a un servicio odontológico móvil y ofrece evidencia sólida sobre la viabilidad de su puesta en marcha a partir de una investigación realizada en la zona 7 de Lima Metropolitana; la misma que dio como resultado la presencia de una demanda latente y aún insatisfecha en relación a este tipo de servicio. Hoy más que nunca existe una gran preocupación por el cuidado de la sonrisa y como consumidores estamos cada vez más acostumbrados a obtener servicios y productos con el menor esfuerzo posible. Es así que este servicio odontológico a móvil está orientado a satisfacer una expectativa básica del consumidor actual en relación a la conveniencia y proximidad que espera de todo tipo de servicio y/o producto. Para su ejecución este proyecto requerirá de una inversión inicial total de S/ 1,619,862. Suma que será financiada en un 40% con un préstamo de un inversionista y el 60% restante con aporte de tres accionistas, quienes esperan recuperar su inversión al término del primer año de operaciones. / The present project refers to a mobile dental service and offers solid evidence on the feasibility of its implementation based on an investigation carried out in zone 7 of Metropolitan Lima; the same that resulted in the presence of a latent and still unsatisfied demand in relation to this type of service. Nowadays there is a great concern about the care of the smile and as consumers we are increasingly accustomed to obtain services and products with the least possible effort. For this reason, this mobile dental service is aimed at satisfying a basic expectation of the current consumer in relation to the convenience and proximity expected from all types of services and/or products. For its execution this project will require a total initial investment of S/ 1,619,862. Amount that will be financed in 40% with a investor loan and 60% with the contribution of three shareholders, who expect to recover their investment at the end of the first year of operations. / Trabajo de investigación
47

Resina industrial de poliuretano modificada com terra diatomácea para ser empregada na modelagem odontológica / Industrial Polyurethane resin modified with diatomacea land to be used in the dental modeling

Avila, Gisseli Bertozzi de 27 August 2009 (has links)
Este estudo avaliou a resina de poliuretano de alto desempenho 6470 e endurecedor Dt 082 (Huntsman Advanced Materials Química Brasil Ltda., fornecido pela Maxepoxi, Santo Amaro, São Paulo, Brasil) carregada com 30 % diatomita para ser empregada na modelagem odontológica. O material foi manipulado na proporção de 1/8 entre resina e endurecedor, com acréscimo de acelerador de poliuretano na proporção de uma gota para cada 200gramas de resina. Foram obtidas amostras de resina pura, modificada com diatomita e gesso tipo IV(Fuji Rock EP), GC America Inc-USA para os ensaios de resistência a compressão e tração por compressão diametral ASTM D 695 2(a), resistência a fratura por impacto ISO 179-1: 2000., resistência a flexão três pontos (ISO 1567:1999), resistência ao desgaste por abrasão norma ASTM D 4060. Amostras foram analisadas quanto ao comportamento dimensional em um projetor de perfil (Mitutoyo PJ-A3000 Japão), a rugosidade superficial Ra, e capacidade de copia de detalhes foram analisadas em Rugosímetro (Mitutoyo Surftest SJ-301 - Japão), a dureza superficial foi analisada em durômetro Sussen Wolpert, tipo Testor HT1 com método de Dureza Rockwell. A compatibilidade da resina com elastômeros de moldagem foi analisada com os criterios aderência do material de modelagem no molde e alteração na coloração do modelo obtido. O ensaio de resistência a compressão e tração por compressão diametral foram realizados na Máquina Universal de Ensaios DL2000 EMIC, com célula de carga de 2000 Kgf e velocidade de 1,3 mm/min. O ensaio de flexão foi realizado no mesmo equipamento com distância entre os apoios de 52 mm, célula de carga de 2000 Kgf e velocidade de 5 mm/min. O ensaio de resistência a fratura por impacto foi realizado na Máquina de Impacto CEAST modelo Resil 25 utilizando ensaio tipo Charpy. O ensaio de resistência ao desgaste por abrasão foi realizado em abrasímetro TABER, que determina a perda de massa por 1000 ciclos, utilizando o rebolo padrão CS-17 com 1000g de carga, ASTM D 4060. Os dados obtidos foram analisados estatisticamente variância e tukey com significância de 95%, e verificou-se que: A resina de poliuretano pura ou modificada com diatomita sobre os dois critérios adotados é compatível com silicone de condensação e adição; a capacidade de cópia da resina foi reduzida com a adição de diatomita mas permaneceu superior ao gesso tipo IV; a diatomita interferiu na rugosidade superficial da resina de poliuretano mas os valores foram menores que os apresentados pelo gesso tipo IV; a diatomita adicionada na resina de poliuretano aumentou a dureza superficial, a resistência a compressão, a tração por compressão diametral, a resistência ao desgaste por abrasão, ao impacto, e a flexão três pontos. A resina pura e a modificada com diatomita foram superiores ao gesso tipo IV para resiste resistência a compressão, a tração por compressão diametral, a resistência ao desgaste por abrasão, ao impacto e a flexão três pontos. Verificou-se comportamento dimensional semelhante para o gesso tipo IV e a resina de poliuretano modificada com diatomita, a resina pura contraiu, a diatomita reduziu a contração da resina de poliuretano. Com a realização desse estudo concluiu-se que: A resina de poliuretano pura ou modificada com diatomita é compatível com os elastômeros silicone de condensação e adição; a carga diatomita no percentual de 30% aumenta a dureza superficial, a resistência a compressão, a resistência a tração por compressão diametral, a resistência a fratura por impacto, a resistência a flexão três pontos, e a resistência ao desgaste por abrasão da resina de poliuretano; a resina de poliuretano quando modificada com 30% de diatomita apresenta comportamento dimensional semelhante ao gesso tipo IV; a diatomita reduziu a capacidade de copia da resina de poliuretano e aumentou sua rugosidade superficial, mas a resina carregada apresentou menor rugosidade superficial e maior capacidade de cópia que o gesso tipo IV; diante dos resultados encontrados com a modificação da resina de poliuretano com 30% de diatomita existe a viabilidade do uso desse material na modelagem odontológica / This study evaluated the high performance polyurethane resin 6470 and hardener Dt 082 (Huntsman Advanced Materials Química Brasil Ltda., supplied by Maxepoxi, Santo Amaro, São Paulo, Brazil) loaded with 30 % diatomite, for use in dental modeling. The material was manipulated in the ratio of 1:8 between resin and hardener, with the addition of the polyurethane accelerator in the proportion of one drop for each 200 grams of resin. Samples of pure resin, modified with diatomite type IV plaster (Fuji Rock EP), GC America Inc-USA, were obtained for the following tests: resistance to compression; diametral compression test ASTM D 695 2(a) to obtain tensile strength, and resistance to fracture by impact ISO 179-1: 2000., three point bending flexural test (ISO 1567:1999); resistance to wear by abrasion, Standard ASTM D 4060. Samples were analyzed with regard to dimensional behavior in a profile projector (Mitutoyo PJ-A3000 Japan); surface roughness Ra, and capacity to copy details were analyzed in a Roughness meter (Mitutoyo Surftest SJ-301 - Japan), surface hardness was analyzed in a Sussen Wolpert durometer Type Tester HT1, with the Rockwell Hardness method. The compatibility of the resin with molding elastomers was analyzed by the criteria of modeling material adherence to the mold and color alteration of the model obtained. The resistance to compression test and diametral compression test for tensile strength were performed in a Universal Test Machine EMIC DL2000, with a 2000 Kgf load cell and speed of 1.3 mm/min. The bending flexural test was performed in the same equipment with a distance of 52 mm between the supports, 2000 Kgf load cell and speed of 5 mm/min. The resistance to fracture by impact was tested in a CEAST Impact Machine model Resil 25 using the Charpy type test. The test for resistance to wear by abrasion was performed in a TABER abrasimeter, which determines the loss of mass per 1000 cycles, using the standard CS-17 abrasive wheel (grindstone) with a 1000g load, ASTM D 4060. The data obtained were statistically analyzed by the analysis of variance and Tukey tests at the level of significance of 95%, and it was verified that: The pure or diatomite-modified polyurethane resin, considering the two criteria adopted, is compatible with condensation and addition silicone; the copying capacity of the resin was reduced with the addition of diatomite, but remained superior to that of type IV plaster; the diatomite interfered in the surface roughness of the polyurethane resin, but the values were lower than those presented by the type IV plaster; diatomite added to the polyurethane resin increased the surface hardness, resistance to compression, traction resistance to diametral compression, resistance to wear by abrasion, impact, and to three point bending flexure. The pure and diatomite-modified polyurethane resin were superior to type IV plaster for resistance to compression, traction resistance to diametral compression, resistance to wear by abrasion, impact and three point bending flexure. Similar dimensional behavior was verified for type IV plaster and diatomite-modified polyurethane resin; the pure resin contracted, and the diatomite reduced polyurethane resin contraction. Conducting this study enabled the following conclusions to be drawn: The pure or diatomite-modified polyurethane resin is compatible with the condensation and addition silicone elastomers; the diatomite load of silicone percent increases the surface hardness, resistance to compression, traction resistance to diametral compression, resistance to fracture by impact, resistance to three point bending flexure, and resistance to wear by abrasion of polyurethane resin; when polyurethane resin is modified with 30% diatomite it has a dimensional behavior similar to that of type IV plaster; the diatomite reduced the polyurethane resin capacity to copy and increased its surface roughness, but the loaded resin presented less surface roughness and greater capacity to copy than the type IV plaster; in view of the results found by modifying the polyurethane resin with 30% diatomite, it is feasible to use this material in dental modeling.
48

Avaliação do comportamento mecânico e da microestrutura de duas marcas comerciais de zircônia monolítica 3Y-TZP sob influência de diferentes parâmetros de sinterização / Microstructural and mechanical evaluation of two commercial monolithic 3YTZP zirconia under various sintering conditions

Catramby, Marcela Ferraz 21 March 2014 (has links)
Cerâmicas a base de zircônia para coroas e próteses fixas monolíticas prometem suprimir a vulnerabilidade ao lascamento de restaurações de múltiplas camadas, proporcionando estética e resistência mecânica simultâneas. No entanto, é possível que as alterações realizadas para maximizar suas propriedades óticas possam afetar a resistência mecânica. O presente estudo teve por objetivo comparar, com base na microestrutura, o comportamento mecânico de duas marcas comerciais de zircônias monolíticas a uma zircônia convencional para infraestruturas, observando ao mesmo tempo algumas variações nos parâmetros de sinterização. As zircônias monolíticas ceramill Zolid e Prettau e a zircônia convencional IPS e.max ZirCAD foram sinterizadas sob a temperatura preconizada pelos respectivos fabricantes, formando os grupos Z1450, P1600 e I1530. Adicionalmente, foram criados os grupos Z1530 e Z1600, representados pela zircônia ceramill Zolid submetida a ciclos modificados. Foram confeccionados 13 corpos de prova para cada grupo, os quais foram submetidos aos ensaios de difração de raios-x, densidade, análise do tamanho médio de grão e resistência à flexão em 4 pontos. Os espectros de difração revelaram a presença da fase tetragonal metaestável em todos os grupos antes e após a sinterização. Quanto à densidade, apresentou-se superior a 99% apenas nos grupos formados pelas zircônias Prettau e IPS e.max ZirCAD. O tamanho médio dos grãos permaneceu abaixo de 1m em todas as situações, sendo maior para o grupo P1600 (0,814m) e menor para o grupo Z1450 (0,463m). Embora tenha sido observada uma tendência de melhoria nos resultados sob taxa de aquecimento mais lenta, os grupos formados pela zircônia monolíticas ceramill Zolid obtiveram os valores mais baixos de confiabilidade (m=4,58 para Z1530) e de resistência mecânica (621,01±138,08MPa para Z1450). A zircônia Prettau apresentou valores de resistência mecânica mais altos e homogêneos (864,18±118,21MPa), contudo inferiores aos da zircônia convencional (1057,41±150,54MPa). Os resultados revelam que as zircônias monolíticas sob estudo possuem características microestruturais e propriedades mecânicas distintas das observadas para a zircônia convencional. / Monolithic zirconia ceramics for crown and bridge applications were designed to eliminate chipping trends of bilayered restorations, providing both aesthetic and mechanical strength. Nonetheless, it has been suggested that improvements in optical properties may affect the mechanical strength of these materials. The present study aimed to compare, based on a microstructural analysis, the mechanical behavior of two commercial monolithic zirconia ceramics with a conventional core zirconia material, as well as to verify sintering parameters modifications. Two monolithic zirconia ceramics (Ceramill Zolid and Prettau) and a conventional core zirconia material (IPS e.max ZirCAD) were sintered according to manufacturer´s recommendations, forming groups Z1450, P1600 and I1530. Extra groups, Z1530 and Z1600, were originated from ceramill Zolid zirconia specimens subjected to modified sintering cycles. The thirteen specimens that were manufactured for each group were submitted to x-ray diffraction analysis, density, average grain size determination and 4-point-bending tests. X-ray diffraction analysis revealed the presence of tetragonal metastable phase in all groups before and after sintering. Relative density found for Prettau and IPS e.max ZirCAD were greater than 99%. The average grain size remained below 1m for all groups. P1600 showed the largest grain sizes (0,814m) while Z1450 (0,463m) demonstrated the smallest ones. Groups originated from ceramill Zolid also presented the lowest Weibull modulus (m=4,58 for Z1530) and flexural strength results (621,01±138,08MPa for Z1450), regardless of non significant improvements that were achieved when using a low heating rate protocol. Prettau zirconia showed better mechanical behaviour and a more homogeneous distribution of results (864,18±118,21MPa), although lower than those of IPS e.max ZirCAD zirconia (1057,41±150,54MPa). Findings from this study show that the two commercial monolithic zirconia under analysis developed distinct mechanical properties and microstructural features from data established for conventional zirconia.
49

Resina industrial de poliuretano modificada com terra diatomácea para ser empregada na modelagem odontológica / Industrial Polyurethane resin modified with diatomacea land to be used in the dental modeling

Gisseli Bertozzi de Avila 27 August 2009 (has links)
Este estudo avaliou a resina de poliuretano de alto desempenho 6470 e endurecedor Dt 082 (Huntsman Advanced Materials Química Brasil Ltda., fornecido pela Maxepoxi, Santo Amaro, São Paulo, Brasil) carregada com 30 % diatomita para ser empregada na modelagem odontológica. O material foi manipulado na proporção de 1/8 entre resina e endurecedor, com acréscimo de acelerador de poliuretano na proporção de uma gota para cada 200gramas de resina. Foram obtidas amostras de resina pura, modificada com diatomita e gesso tipo IV(Fuji Rock EP), GC America Inc-USA para os ensaios de resistência a compressão e tração por compressão diametral ASTM D 695 2(a), resistência a fratura por impacto ISO 179-1: 2000., resistência a flexão três pontos (ISO 1567:1999), resistência ao desgaste por abrasão norma ASTM D 4060. Amostras foram analisadas quanto ao comportamento dimensional em um projetor de perfil (Mitutoyo PJ-A3000 Japão), a rugosidade superficial Ra, e capacidade de copia de detalhes foram analisadas em Rugosímetro (Mitutoyo Surftest SJ-301 - Japão), a dureza superficial foi analisada em durômetro Sussen Wolpert, tipo Testor HT1 com método de Dureza Rockwell. A compatibilidade da resina com elastômeros de moldagem foi analisada com os criterios aderência do material de modelagem no molde e alteração na coloração do modelo obtido. O ensaio de resistência a compressão e tração por compressão diametral foram realizados na Máquina Universal de Ensaios DL2000 EMIC, com célula de carga de 2000 Kgf e velocidade de 1,3 mm/min. O ensaio de flexão foi realizado no mesmo equipamento com distância entre os apoios de 52 mm, célula de carga de 2000 Kgf e velocidade de 5 mm/min. O ensaio de resistência a fratura por impacto foi realizado na Máquina de Impacto CEAST modelo Resil 25 utilizando ensaio tipo Charpy. O ensaio de resistência ao desgaste por abrasão foi realizado em abrasímetro TABER, que determina a perda de massa por 1000 ciclos, utilizando o rebolo padrão CS-17 com 1000g de carga, ASTM D 4060. Os dados obtidos foram analisados estatisticamente variância e tukey com significância de 95%, e verificou-se que: A resina de poliuretano pura ou modificada com diatomita sobre os dois critérios adotados é compatível com silicone de condensação e adição; a capacidade de cópia da resina foi reduzida com a adição de diatomita mas permaneceu superior ao gesso tipo IV; a diatomita interferiu na rugosidade superficial da resina de poliuretano mas os valores foram menores que os apresentados pelo gesso tipo IV; a diatomita adicionada na resina de poliuretano aumentou a dureza superficial, a resistência a compressão, a tração por compressão diametral, a resistência ao desgaste por abrasão, ao impacto, e a flexão três pontos. A resina pura e a modificada com diatomita foram superiores ao gesso tipo IV para resiste resistência a compressão, a tração por compressão diametral, a resistência ao desgaste por abrasão, ao impacto e a flexão três pontos. Verificou-se comportamento dimensional semelhante para o gesso tipo IV e a resina de poliuretano modificada com diatomita, a resina pura contraiu, a diatomita reduziu a contração da resina de poliuretano. Com a realização desse estudo concluiu-se que: A resina de poliuretano pura ou modificada com diatomita é compatível com os elastômeros silicone de condensação e adição; a carga diatomita no percentual de 30% aumenta a dureza superficial, a resistência a compressão, a resistência a tração por compressão diametral, a resistência a fratura por impacto, a resistência a flexão três pontos, e a resistência ao desgaste por abrasão da resina de poliuretano; a resina de poliuretano quando modificada com 30% de diatomita apresenta comportamento dimensional semelhante ao gesso tipo IV; a diatomita reduziu a capacidade de copia da resina de poliuretano e aumentou sua rugosidade superficial, mas a resina carregada apresentou menor rugosidade superficial e maior capacidade de cópia que o gesso tipo IV; diante dos resultados encontrados com a modificação da resina de poliuretano com 30% de diatomita existe a viabilidade do uso desse material na modelagem odontológica / This study evaluated the high performance polyurethane resin 6470 and hardener Dt 082 (Huntsman Advanced Materials Química Brasil Ltda., supplied by Maxepoxi, Santo Amaro, São Paulo, Brazil) loaded with 30 % diatomite, for use in dental modeling. The material was manipulated in the ratio of 1:8 between resin and hardener, with the addition of the polyurethane accelerator in the proportion of one drop for each 200 grams of resin. Samples of pure resin, modified with diatomite type IV plaster (Fuji Rock EP), GC America Inc-USA, were obtained for the following tests: resistance to compression; diametral compression test ASTM D 695 2(a) to obtain tensile strength, and resistance to fracture by impact ISO 179-1: 2000., three point bending flexural test (ISO 1567:1999); resistance to wear by abrasion, Standard ASTM D 4060. Samples were analyzed with regard to dimensional behavior in a profile projector (Mitutoyo PJ-A3000 Japan); surface roughness Ra, and capacity to copy details were analyzed in a Roughness meter (Mitutoyo Surftest SJ-301 - Japan), surface hardness was analyzed in a Sussen Wolpert durometer Type Tester HT1, with the Rockwell Hardness method. The compatibility of the resin with molding elastomers was analyzed by the criteria of modeling material adherence to the mold and color alteration of the model obtained. The resistance to compression test and diametral compression test for tensile strength were performed in a Universal Test Machine EMIC DL2000, with a 2000 Kgf load cell and speed of 1.3 mm/min. The bending flexural test was performed in the same equipment with a distance of 52 mm between the supports, 2000 Kgf load cell and speed of 5 mm/min. The resistance to fracture by impact was tested in a CEAST Impact Machine model Resil 25 using the Charpy type test. The test for resistance to wear by abrasion was performed in a TABER abrasimeter, which determines the loss of mass per 1000 cycles, using the standard CS-17 abrasive wheel (grindstone) with a 1000g load, ASTM D 4060. The data obtained were statistically analyzed by the analysis of variance and Tukey tests at the level of significance of 95%, and it was verified that: The pure or diatomite-modified polyurethane resin, considering the two criteria adopted, is compatible with condensation and addition silicone; the copying capacity of the resin was reduced with the addition of diatomite, but remained superior to that of type IV plaster; the diatomite interfered in the surface roughness of the polyurethane resin, but the values were lower than those presented by the type IV plaster; diatomite added to the polyurethane resin increased the surface hardness, resistance to compression, traction resistance to diametral compression, resistance to wear by abrasion, impact, and to three point bending flexure. The pure and diatomite-modified polyurethane resin were superior to type IV plaster for resistance to compression, traction resistance to diametral compression, resistance to wear by abrasion, impact and three point bending flexure. Similar dimensional behavior was verified for type IV plaster and diatomite-modified polyurethane resin; the pure resin contracted, and the diatomite reduced polyurethane resin contraction. Conducting this study enabled the following conclusions to be drawn: The pure or diatomite-modified polyurethane resin is compatible with the condensation and addition silicone elastomers; the diatomite load of silicone percent increases the surface hardness, resistance to compression, traction resistance to diametral compression, resistance to fracture by impact, resistance to three point bending flexure, and resistance to wear by abrasion of polyurethane resin; when polyurethane resin is modified with 30% diatomite it has a dimensional behavior similar to that of type IV plaster; the diatomite reduced the polyurethane resin capacity to copy and increased its surface roughness, but the loaded resin presented less surface roughness and greater capacity to copy than the type IV plaster; in view of the results found by modifying the polyurethane resin with 30% diatomite, it is feasible to use this material in dental modeling.
50

"Hepatite B no Município de Ribeirão Preto (SP): um estudo envolvendo cirurgiões-dentistas e auxiliares odontológicos" / Hepatitis B on the city of Ribeirão Preto, São Paulo, Brazil: a study envolving dentists and dental assistants

Vania Cantarella Rodrigues 26 February 2002 (has links)
Foi realizada uma pesquisa com cirurgiões-dentistas (CDs) e auxiliares odontológicos (AOs) das redes pública e privada, no município de Ribeirão Preto,SP – Brasil, com os objetivos de: 1. avaliar a cobertura vacinal e a efetividade da vacinação contra a hepatite B; 2. verificar o uso de equipamentos de proteção individual (EPIs) na rotina de trabalho; 3. verificar a prevalência de marcadores sorológicos do HBV; 4. analisar possíveis associações entre marcadores sorológicos do HBV e alguns fatores de risco de infecção pelo vírus. A pesquisa contou com 338 participantes, de consultórios e clínicas odontológicas – 201 CDs(26 da rede pública e 175 da rede privada) e 137 AOs (23 da rede pública e 114 da rede privada). Foi aplicado um questionário individual para obter informações referentes a características dos participantes, vacinação contra a hepatite B e fatores de risco relacionados à infecção pelo HBV. Simultaneamente, coletou-se uma amostra de 8 ml de sangue para a pesquisa dos seguintes marcadores sorológicos do HBV: HBsAg, anti-HBc e anti-HBs. Todos os exames foram feitos, através de técnicas imunoenzimáticas, no Laboratório de Sorologia do Hospital das Clínicas da Faculdade de Medicina de Ribeirão Preto - USP. Estavam vacinados com três doses ou mais da vacina contra a hepatite B 80,6% dos CDs (80,8% da rede pública e 80,6% da rede privada) e 24,8% dos AOS(82,6% da rede pública e 13,2% da rede privada). A prevalência de anti-HBs entre os vacinados com três doses ou mais da vacina foi de 84,3% - 84,6% entre CDs e 82,8% entre AOs. A prevalência dos marcadores sorológicos do HBV ficou assim distribuída: HBsAg, 0,5% entre CDs, não encontrado entre AOs; anti-HBc, 9,5% entre CDs (IC 95%: 5,4% - 13,5%) e 2,9% entre AOs (IC 95%: 0,1% - 5,7%);anti-HBs, 78,1% entre CDs (IC 95%: 72,3% - 83,8%) e 29,9% entre AOs (IC 95%: 22,2 - 37,6%). Os EPIs mais utilizados pelos CDs eram as luvas, com percentual de 98,0%, e a máscara, com 96,5%, no atendimento de todos os pacientes. Os CDs da rede privada utilizavam os seguintes EPIs: luvas, 97,7%; máscara, 96,0%; óculos de proteção, 70,3%; avental, 55,4%; gorro 32,6%. Os CDs da rede pública usavam os seguintes EPIs: luvas e máscaras, 100,0%; avental, 88,5%; óculos de proteção, 65,4%; gorro, 30,8%. O EPI mais utilizado pelos AOs eram as luvas, com percentual de 97,1%. Os AOs da rede pública utilizavam: luvas, 100,0%; avental, 95,7%; máscara, 78,3%; óculos de proteção; 34,8%; gorro, 17,4%. Os AOs da rede privada utilizavam: luvas, 96,5%; máscara, 37,7%; avental, 28,1%; óculos de proteção, 11,4%; gorro, 10,5%. Dos AOs da rede privada, 3,5% referiram não usar nenhum EPI. O estudo mostrou que a prevalência dos marcadores sorológicos do HBV entre CDs e AOs é semelhante à da população de pacientes de Unidades de Saúde de Ribeirão Preto e que parte dos profissionais, especialmente os AOs, negligenciam a proteção pela imunização ativa e uso de EPIs. / A survey was carried out among dentists (D) and dental assistants (DA) of the public and the private sectors in the city of Ribeirão Preto, São Paulo, Brazil, in order to a) evaluate the vaccine coverage as well as the effectiveness of the vaccination against hepatitis B; b) check for the presence of serological markers of the hepatitis B virus(HBV)infection; assess the use of individual protection equipments (IPE). The survey,involving 338 participants working in dentist private offices or in dental clinics, comprised 201 D (26 of the public sector and 175 of the private sector) and 137 DA(23 of the public sector and 114 of private practices). Individual survey questionnaires were used to gather information regarding the participants, the vaccination against hepatitis B, and the risk factors related to the HBV infection. Blood samples (8 ml) were collected to assess the following serological markers for the HBV infections: HBsAg, Anti-HBc, and Anti-HBs. All essays were done with the immunoenzimatic technique by the Serological Laboratory of the Hospital das Clinicas of the University of São Paulo Medical School, at Ribeirão Preto. A higher proportion of the D compared to the DA were vaccinated with three or more doses of the hepatitis B: 80.6% of the D (80.8% of the public sector and 80.6% of the private sector) but only 24,8% of the DA (82.6% of the public sector and 13,2% of the private sector). Among those vaccinated with three or more doses 84.3% (84.6% for D and 82.8% for DA) presented positive tests for the anti-HBs marker. Considering the whole population evaluated, the occurrence of serological markers for HBV infection was distributed as follows: HBsAg, 0.5% in D and zero in DA; anti-HBc, 9.5% in D (95% CI: 5.4% to 13.5%) and 2.9% in DA (95% CI: 0.1% to 5.7%); and anti-HBs, 78.1% in D (95% CI: 72.3% to 83.8%) and 29.9% in DA (95% CI: 22.2% to 37.6%). Most dentists make use of some IPE when treating patients: 98.0% wore gloves and 96.5% face masks. There was little difference in use of IPE between dentists working in the private and the public sectors: for the former 97.7% wore gloves, 96.0% face masks, 70.3% protective eyewear, 55.4% protective uniform, and 32.6% caps; for the later, 100% wore gloves and face masks, 88.5% protective uniform, 65.4% protective eyewear, and 30.8% caps. A high percentage of the DA also wore IPEs, although the numbers were lower for those of the private sector. Among the former group 100% wore gloves, 95.7% protective uniform, 78.3% face masks, 34.8% protective eyewear, and 17.4% caps. The corresponding figures for the DA of the private dental offices and clinics were: 96.5% wore gloves, 37.7% face masks, 28.1% protective uniform, 11.4% protective eyewear, and 10.5% caps. A small percentage (3.5%) of the DA working in the private sector did not report the use of any IPE. The study showed that the occurrence of serological markers for infection with HBV in dental professionals is similar to that of the population as a whole, and that part of the professionals, especially the DAs, neglect to secure protection by active immunization and use of IPEs.

Page generated in 0.0639 seconds