• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 148
  • 12
  • 9
  • 9
  • 9
  • 9
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 161
  • 87
  • 51
  • 40
  • 36
  • 26
  • 26
  • 22
  • 20
  • 20
  • 20
  • 18
  • 17
  • 17
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Esterilização de pontas diamantadas através da energia por microondas /

Farias, Renata Jansen de Mello. January 2003 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Alma Blásida Concepción Elizaur Benitez / Banca: Antonio Carlos Pizzolitto / Resumo: Tendo em vista a importância e necessidade de esterilização dos instrumentos cortantes rotatórios usados em odontologia, associada à indispensável agilidade nos atendimentos e, considerando ainda, a escassez de publicações atuais voltadas para este tema, julgou-se válida a preocupação em estudar a efetividade do método de esterilização através da energia por microondas em pontas diamantadas. Para tal, oitenta e uma pontas diamantadas foram contaminadas em uma suspensão bacteriana formada por bactérias pertencentes ao meio bucal (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divididas em três diferentes grupos e submetidas à irradiação por microondas em forno de microondas doméstico na potência máxima (800 W). Os grupos foram diferenciados entre si conforme o método de acondicionamento dos corpos-de-prova (2) e o procedimento para esterilização (3). No Procedimento de esterilização P1, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados em placas de Petri contendo 40 mL de água e submetidos à irradiação por microondas nos períodos de 0, 1, 2 e 3 minutos. No Procedimento de esterilização P2, os corpos-de-prova foram envolvidos em folha de poliéster, acondicionados em envelopes para esterilização e expostos à energia por microondas nos períodos de 0, 2, 4, 5 e 6 minutos, sem sofrerem previamente o procedimento de limpeza. E no Procedimento de esterilização P3, os corpos-de-prova foram limpos com esponja de aço em água corrente, acondicionados e submetidos à irradiação conforme o método anterior. A esterilização foi obtida tanto no Procedimento P1, no período de um minuto, quanto no Procedimento P3, no período de 6 minutos. Portanto, pudemos concluir...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Concerning the importance and the need for sterilization of the rotary cutting instruments used in dentistry, associated to the indispensable agility in the appointments and, considering also the scarceness of updated publications in regard to this theme, the preoccupation in studying the effectiveness of the sterilization method by the energy of microwaves in diamond burs was judged valid. To perform such study, eighty-one diamond burs were contaminated in a bacterial suspension formed by bacteria which belong to the oral environment (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Streptococcus mutans, Lactobacillus acidophillus, Actinomyces viscosus, Enterococcus faecalis e Bacillus subtilis), divided in three different groups and submitted to irradiation by microwaves in a domestic microwave oven on maximum power (800 W). The groups were discriminated according to the method of packing of the specimens (2) and the procedure for sterilization (3). In the procedure for sterilization 1, the specimens were cleaned with steel sponge in water, packed in Petri dishes containing 40 mL of water and submitted to irradiation by microwaves in the periods of 0, 1, 2 and 3 minutes. In the procedure for sterilization 2, the test specimens were wrapped in a polyester sheet, packed in envelopes for sterilization and exposed to energy by microwaves in the periods of 0, 2, 4, 5 and 6 minutes, without going through the cleaning procedure previously. Finally, in the procedure for sterilization 3, the test specimens were cleaned with steel sponge in water, packed and submitted to irradiation according to the anterior method. The sterilization was obtained both in procedure 1, in the period of 1 minute, and in procedure 3, in the period of 6 minutes. Therefore, we could conclude that ...(Complete abstract, click electronic access below) / Mestre
82

Avaliação do efeito da afiação com diferentes técnicas sobre o ângulo de corte de curetas de Gracey /

Andrade Acevedo, Roberto Antonio. January 2003 (has links)
Orientador: José Eduardo Cezar Sampaio / Banca: Silvana Regina Perez Orrico / Banca: Joni Augusto Cirelli / Banca: Enilson Antonio Sallum / Banca: Gibson Luiz Pilatti / Resumo: O presente trabalho teve por objetivo avaliar em fotomicrografias obtidas em microscópio eletrônico de varredura (MEV) o ângulo de corte de curetas de Gracey 5-6 em três níveis: afiação de fábrica, após ficarem sem corte e após serem reafiadas utilizando nove diferentes técnicas padronizadas de afiação: 1- face lateral da cureta contra a pedra Arkansas plana; 2- face coronal e posteriormente a lateral contra a pedra Arkansas plana; 3- pedra de Arkansas plana contra a face lateral da cureta; 4- cone de óxido de alumínio a baixa rotação contra a face coronal e em seguida a face lateral da cureta; 5- face lateral da cureta com pedra Arkansas 299; 6- face lateral da cureta com o aparelho padronizador Hu-Friedy; 7- face coronal da cureta com ponta de videa; 8- face coronal da cureta com ponta de videa e em seguida a face lateral com pedra de Arkansas plana; 9- afiação da face coronal com ponta de videa e em seguida pó abrasivo e roda de feltro rotatória na face lateral da cureta. Foram tomadas fotomicrografias (350X) do ângulo de corte e posteriormente avaliadas por um examinador calibrado através do índice do ângulo de corte. A analise estatística de Kruskal Wallis e comparações múltiplas mostraram que as técnicas 1 e 2 foram as melhores técnicas de afiação seguidas das técnicas 6, 5 e 8. As piores técnicas foram a 7, 9, 4, 0 e 3. A reafiação da face coronal das curetas produziu a formação de projeções metálicas não funcionais no ângulo de corte e finalmente não houve diferenças entre a afiação do extremo par e ímpar dos instrumentos em nenhuma das técnicas de afiação utilizadas. / Abstract: A micrographs obtained by a scanning electron microscope (SEM) were used to evaluated the gracey 5-6 cutting edges as the come from manufacture, after they had been dull and after they were resharpened by several standard techniques: 1- lateral surface over a flat Arkansas sharp stone; 2- coronal surface and the a lateral surface over a flat Arkansas sharp stone; 3- lateral surface by passing a flat Arkansas sharp stone; 4- rotatory aluminum oxide stone over a coronal surface and then over a lateral face; 5- lateral surface by passing an Arkansas 299 stone; 6- lateral surface on Hu-Friedy sharp divice; 7- coronal surface by a Whittler Neivert Device; 8- coronal face by a Whittler Neivert Device and the a lateral surface over a flat Arkansas sharp stone; 9- coronal surface with a Whittler Neivert Device and a rotating, impregnated, felt wheel on the lateral surface. The cutting edges was blindly evaluated on micrographs (X350) by one calibrated examiner (cutting angle index). A statistical analysis showed that techniques 1 and 2 were the best ones followed by a 6, 5 and 8 techniques. The worst techniques were a 7, 9, 4, 0 and 3. Resharpened on the coronal face of curettes generated a non functional wire edges on the cutting edge angle and there were not differences between the paired and unpaired extreme of the instruments resharpened. / Doutor
83

Avaliação da degradação de elásticos ortodônticos intraorais de látex / Force extension relaxation of medium force orthodontic latex elastics

Daniel Jogaib Fernandes 10 September 2009 (has links)
Avaliou-se a taxa de degradação de elásticos ortodônticos de látex de diferentes fabricantes e diâmetros em diversos intervalos de tempo. Grupos de 15 elásticos de força média dos fabricantes AmericanOrthodontics (Sheboygan, Wis, EUA), Tp (La Porte, IN, EUA), Morelli (Sorocaba, SP, Brasil) e Uniden (Sorocaba, SP, Brasil); de diâmetros 3/16, 1/4 e 5/16 foram analisados nos intervalos de 0,1,3,6,12 e 24 horas, totalizando-se 1080 espécimes. Os elásticos foram estirados individualmente à distância de 30mm, respeitando-se o intervalo de um minuto entre cada estiramento. Os materiais foram acondicionados imersos em água deionizada à 37C. Realizou-se leitura das forças na máquina de ensaios Emic DL 500 (Emic Co, Sao Paulo, Brasil) à velocidade de 30 mm/min, com uma célula de 2Kg (Emic Co, Sao Paulo, Brasil). A leitura de cada elástico consumiu aproximadamente um minuto. Teste Kruskal-wallis com correções por Dunns aferiu significância estatística dos resultados. Foram observadas diferenças entre os grupos analisados, exceto às marcas Morelli e Tp. Foram significativas as inferências das variáveis tempo e marca comercial. Em 0 hora, a relação entre as forças geradas foi Morelli>AO>Uniden>Tp para elásticos 3/16 (p=0,0016) e 1/4 (p=0,0016) e, de Morelli>AO>Tp>Uniden para elásticos 5/16 (p=0,0087). Após 24 horas, as porcentagens de degradação dos elásticos foram AO>Morelli>Uniden>Tp no diâmetro 3/16; AO>Tp>Morelli>Uniden no diâmetro 1/4 e Tp>AO>Uniden>Morelli para elásticos de diâmetro 5/16. O comportamento no intervalo de 0-24 horas demonstrou uma queda acentuada no período de 0-3 horas, um ligeiro aumento em 3-6 horas, seguido de uma queda progressiva no intervalo de 6-24 horas. / The purpose of this study was to evaluate the force relaxation of different brands and diameters of latex elastics occurring during different times. Groups of 15 medium forces elastics from manufacturers: American Orthodontics (Sheboygan, Wis, USA), Tp (La Porte, IN, USA), Morelli Orthodontics (Sorocaba, SP, Brazil) and Uniden Orthodontics (Sorocaba, SP, Brazil) with diameters: 3/16, 1/4 and 5/16 inch size were tested at 0,1,3,6,12,24 hours, making a total of 1080 specimens. An apparatus was designed to simulate oral environments during elastics stretching. The forces were read after 1,3,6,12 and 24-hour periods in Emic testing machine (Emic Co, Sao Paulo, Brazil) with 30 mm/min cross-head speed and load cell of 2Kg Emic force (Emic Co, Sao Paulo, Brazil). Kruskal-Wallis and Dunns tests were used to identify statistical significance. Overall, there were statistically differences among the different manufacturers at all observation intervals, except between Morelli and Tp. Significantly variability were seen in Morelli and Uniden force delivery. The relationships among loads at 0-hour time period were as follows: Morelli>AO>Uniden>Tp for 3/16 (p=.0016) and 1/4 elastics (p=.0016) and Morelli>AO>Tp>Uniden for 5/16 elastics (p=.0087). The forces relaxation over the 24-hour time period were AO>Morelli>Uniden>Tp for 3/16 elastics; AO>Tp>Morelli>Uniden for 1/4; and Tp>AO>Uniden>Morelli for 5/16 elastics.The force decay pattern show a notable drop-off of forces during 0-3 hours, a slight increase in force values from 3-6 hours and a progressive force decay was seen over 6-24 hours.
84

Desvio, capacidade de centralização e fadiga cíclica promovidos por instrumentos TF Adaptive e Navigator EVO, em diferentes cinemáticas

Duarte, Pedro Henrique Marks January 2017 (has links)
Introdução: A evolução dos instrumentos de NiTi pode ser dividida em gerações de acordo com algumas modificações tais como: tratamento térmico da liga, secção transversal e movimento utilizado para o preparo do canal, que pode ser movimento rotatório contínuo ou movimento oscilatório assimétrico. Essas mudanças tem como objetivo prover maior flexibilidade aos instrumentos, permitindo uma melhor modelagem do canal, com menor desvio e menor risco de perfurações. Outro aspecto relevante é a maior resistência à fadiga cíclica, das ligas com tratamento térmico, colaborando para uma maior resistência à fratura do instrumento. Objetivos: Este estudo comparou a fadiga cíclica, o transporte do canal , a capacidade de centralização e o volume do canal pós preparo, produzidos pelos sistemas TF Adaptive e Navigator EVO, quando utilizados em rotação contínua ou no movimento Adaptive. Métodos: Quarenta raízes mésio-vestibulares de molares superiores foram analisadas através de micro-CT antes e depois do preparo do canal radicular com os dois sistemas e dois movimentos (Adaptive e Rotação Contínua). As amostras foram divididas em quatro grupos: TFA – instrumentos TF Adaptive utilizados no movimento Adaptive; TFC –instrumentos TF Adaptive utilizados em rotação contínua; NA – instrumentos Navigator EVO utilizados no movimento Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Adaptive; e NC – instrumentos Navigator EVO utilizados em rotação contínua. Os canais radiculares foram preparados até instrumentos 35.04. O transporte apical, a capacidade de centralização e o volume de preparo foram analisados utilizando-se micro-CT em três níveis: 3, 6 e 9mm do ápice.O teste de fadiga cíclica foi realizado utilizando um equipamento apropriado, onde, dez instrumentos de cada marca foram utilizados em um contraângulo redutor 6:1 e um motor elétrico com controle de torque, com programas prédefinidos ‘‘custom mode'' e ‘‘TF Adaptive'' para ativar os instrumentos 25.06 e 35.04.Os resultados foram analisados com os testes Kruskal-Wallis eDunn para se verificar o transporte do canal, a capacidade de centralização e o volume do canal. O teste Student-T foi usado para avaliar a fadiga cíclica (P = 0,05). Conclusões: Ambos sistemas podem ser usados no movimento Adaptive ou em rotação contínua. Porém, a resistência à fratura dos instrumentos foi maior quando utilizados em rotação contínua. Pouco transporte de canal ocorreu, quando os canais mésio-vestibulares de molares superiores foram preparados até instrumentos 35.04. / Introduction: The evolution of NiTi instruments can be divided in generations, according to changes like in the NiTi alloy, heat treatment, cross-section format, and in the movement used for root preparation that goes form continuous rotation to asymmetric oscillation. These changes aim to provide greater flexibility to the instruments, allowing a better shaping, with less transportation and risk of perforation. Other aspect is the increased fracture resistance of the alloys with heat treatment, which is a big concern about NiTi instruments. Aim: This study compared the cyclic fatigue and the canal transportation promotedby TF Adaptive and Navigator EVO systems when used with two different motions. Methods: Forty mesiobuccal roots of maxillary molars were scanned using micro-CT imaging before and after root canal preparation with the two instrument systems two motions (adaptive and continuous rotation). Samples were divided into four groups: TFA – TF Adaptive instruments under adaptive motion; TFC - TF Adaptive instruments under continuous motion; NA - Navigator instruments under adaptive motion; and NC – Navigator instruments under continuous motion. Root canals were prepared until 35.04 instruments. Apical transportation, centering ability and volume were analyzed using micro- CT at three levels: 3, 6 and 9 mm from the apex. The cyclic fatigue tests were performed using a custom-made device. Ten instruments of each brand were activated by using a 6:1 reduction handpiece powered by a torque-controlled motor using the preset programs ‘‘custom mode'' and ‘‘TF Adaptive'' to activate25.06 and 35.04 instruments. Data were analyzed with Kruskal-Wallis and Dunn tests were used to assess canal transportation, centering ability and canal volume. Student-T test was used to evaluate cyclic fatigue (P = .05). Conclusions: Both systems can be used under adaptive or continuous rotation. However; the lifespan of the instruments was higher when used under continuous rotation. Little canal transportation occurred when mesiobuccal root canals from maxillary molars were prepared until 35.04instruments.
85

Investigação de um ambiente computacional para tomada de decisão em tratamentos odontológicos baseado em sistema especialista

Gomes de Magalhães Neto, José 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T16:01:31Z (GMT). No. of bitstreams: 2 arquivo9419_1.pdf: 1374398 bytes, checksum: 76832205ae37ac03060aa290575a2470 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O alto índice de despesas com a sinistralidade de tratamentos odontológicos tem dificultado o equilíbrio econômico e orçamentário das empresas operadoras de planos odontológicos. A busca por soluções mediada pela Tecnologia da Informação tem o propósito de diminuir tais custos de operação e tem sido um dos objetos de estudo dessas empresas. Um dos principais motivadores para o aumento da sinistralidade concentra-se na forma como a operadora autoriza a execução dos tratamentos odontológicos solicitados por seus prestadores de serviço (dentista). O grande desafio dos peritos é estabelecer o equilíbrio entre a detecção de incoerências em tempo hábil, de tal forma que não prejudique o atendimento dos beneficiários, sem permitir a efetivação de despesas indevidas. Este trabalho tem o objetivo de investigar deficiências que uma empresa operadora de plano odontológico de médio porte possui para avaliar os tratamentos solicitados. Utilizando-se a notação Business Process Modeling Notation (BPMN) foi realizado um mapeamento dos processos envolvendo todo o ciclo dos planos de tratamento, identificando os fatores críticos que comprometem a qualidade do processo de tomada de decisão sob as autorizações concedidas. Também é abordado como o ambiente computacional existente na empresa automatiza esses processos. Baseado nessa análise é proposto o redesenho dos processos críticos apoiados por um Sistema Especialista (SE), que integrado ao ambiente computacional existente visa suprir as necessidades identificadas. No SE proposto são abordadas técnicas para representar o conhecimento utilizado pelos peritos durante o processo de tomada de decisão
86

Avaliação dos Centros de Especialidades Odontológicas Regionais gerenciados pelos Consórcios Públicos de Saúde do Ceará

ANDRADE, Edlane Martins de 30 March 2016 (has links)
Submitted by Alice Araujo (alice.caraujo@ufpe.br) on 2018-04-24T18:05:37Z No. of bitstreams: 1 DISSERTAÇÃO Edlane Martins de Andrade.pdf: 4477425 bytes, checksum: b135480f266c26f9ebbae7d4181c98c0 (MD5) / Made available in DSpace on 2018-04-24T18:05:37Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO Edlane Martins de Andrade.pdf: 4477425 bytes, checksum: b135480f266c26f9ebbae7d4181c98c0 (MD5) Previous issue date: 2016-03-30 / CAPES / Este trabalho teve como objetivo avaliar o desempenho dos Centros de Especialidades Odontológicas Regionais gerenciados pelos consórcios públicos de saúde no estado do Ceará nos anos de 2013, 2014 e 2015. Optar por essas unidades atribuiu-se ao fato de ser um caso inédito de um modelo de gestão consorciado aplicado ao serviço público odontológico especializado e normatizado pela Política Nacional de Saúde Bucal – Brasil Sorridente. Norteada a investigação em verificar se os serviços ofertados nesse modelo de gestão são eficazes, utilizou-se como abordagem metodológica a pesquisa avaliativa de natureza quantitativa aplicando o índice de Cumprimento Global de Metas (CGM) conforme os procedimentos preconizados pela Portaria N. 1464/11 para qualificar as atividades dessas dezesseis unidades. A investigação envolveu revisão bibliográfica, análise documental e fontes de dados secundários que permitiram contextualizar a atenção secundária na política de saúde bucal do estado. Verificou-se uma expressiva expansão de serviços odontológicos públicos especializados nos três anos analisados, com melhor rendimento para o ano de 2015. O resultado da avaliação de desempenho, ainda que não tenham trazido resultados satisfatórios, demonstraram dados crescentes num quadro progressivo de avanço; pois do ano de 2013 para 2015, o desempenho considerado como bom ou ótimo cresceu de 12,5% para 43,8% enquanto que a classificação de regular e ruim caiu de 87,5% para 56.2% no mesmo intervalo de tempo. O estudo ainda permitiu identificar que apesar dos consórcios públicos de saúde serem instrumentos de planejamento para organizar o fluxo dos pacientes que buscam de assistência odontológica; estes por si só não garantiram o acesso dos cidadãos a esses serviços; tendo em vista, que estes dependiam da atuação de referências municipais estabelecidas por meio da pactuações entre os municípios e o Estado. Por fim, alguns desafios ficaram a serem sugeridos em trabalhos futuros, um deles se trata da continuidade do processo avaliativo para os anos subsequentes analisando a produção de desempenho com outras variáveis e o outro, seria de fortalecer a institucionalidade da política de saúde bucal assegurando como direito de cidadania aos cearenses que, em contextos adversos, esses equipamentos de saúde não sejam subutilizados. / This study aimed to evaluate the performance of Regional Dental Specialty Centers managed by public health consortium in the state of Ceara in the years 2013, 2014 and 2015. Opting for these units was attributed to being a unique case of a model intercropping of management applied to specialized dental public service and regulated by the National Oral Health Policy -Smiling Brazil. Guided research to verify that the services offered in this management model are effective, it was used as a methodological approach to evaluative research quantitative applying the Global Compliance index Goals (CGM) as the procedures recommended by Decree N. 1464/11 to describe the activities of these sixteen units. The research involved literature review, document analysis and sources of secondary data that allowed contextualize secondary care in the health policy of the state. There was a significant expansion of dental services specialized in the three years analyzed, with better performance for the year 2015. The result of the performance evaluation, although they have not brought satisfactory results, demonstrated growing data in a progressive frame advance; since the year 2013 to 2015, performance considered as good or excellent increased from 12.5% to 43.8% while that of regular and bad rating fell from 87.5% to 56.2% in the same time interval. The study also identified that despite public health consortia are planning tools to organize the flow of patients seeking dental care; these alone did not guarantee citizens' access to such services; with a view, they depended on the performance of municipal references established by pacts between municipalities and the state. Finally, some challenges were to be suggested in future work, one of them is the continuation of the evaluation process for subsequent years analyzing the performance of production with other variables and the other would be to strengthen the institutional framework of health policy ensuring as right to citizenship Cearense that in adverse contexts, these health facilities are not underutilized.
87

"A influência do tabagismo no insucesso dos tratamentos odontológicos" / "The influence of tobacco smoking in the failure of the dental treatment"

Solange Lilia Masi Daud 20 March 2003 (has links)
O objetivo do presente trabalho foi realizar uma revisão bibliográfica sobre os efeitos que o hábito de fumar pode ter sobre o periodonto e o peri-implante, para alertar a classe odontológica sobre os cuidados que deve pacientes fumantes, bem como contribuir para o esclarecimento da área jurídica, carente desses conhecimentos, na solução dos problemas eventualmente envolvidos na avaliação da responsabilidade civil profissional do cirurgião-dentista. Como decorrência da revisão da literatura e da discussão empreendida, concluiu-se que: o tabagismo tem efeito deletério sobre a saúde bucal, constituindo-se no maior fator de risco para as doenças periodontais conhecido na atualidade; os principais efeitos nocivos do hábito de fumar sobre o periodonto são: diminuição da vascularização, alteração na resposta inflamatória e imunológica, bolsas periodontais mais profundas, maior perda de inserção periodontal e interferência na cicatrização pós-terapias; no que concerne ao peri-implante, o tabagismo provoca: vasoconstrição sistêmica, redução do fluxo sangüíneo, maior probabilidade de desenvolver peri-implantite e interferência na cicatrização pós-cirúrgica; o cirurgião-dentista precisa verificar se o paciente é fumante ou não, para esclarecê-lo e conscientizá-lo sobre os riscos que esse hábito traz à saúde e, conseqüentemente, aos tratamentos e trabalhos odontológicos reabilitadores, podendo levá-los ao insucesso, pois é o periodonto que os sustenta; o paciente deve manifestar-se sobre a vontade de abandonar esse hábito ou não, e o profissional deve documentar os esclarecimentos que lhe forneceu e a decisão que deles resultou, arquivando esse documento no prontuário odontológico, a fim de se resguardar no caso de eventuais ações impetradas contra si. / SUMARY The purpose of the present work was to perform a bibliographic revision on the effects that smoking habits might have on the periodontium and the peri-implant, in order to alert dentists about the care that must be taken in regard to the warning about the risks posed to the patients who smoke, as well as to advise legal professionals in need for such knowledge, in the solution of the problems that eventually arise when evaluating the legal responsibilities of the professional surgeon. As a result of the revision of the literature and the discussion enticed, it has been concluded that tobacco smoking has a deleterious effect on the dental health, making it the greatest risk factor for the periodontal diseases known today; the main noxious effects of the smoking habit on the periodontium are: lower vascularization, change in the inflammatory and immunological response, deeper periodontal pockets, greater loss of periodontal attachment and post-therapy healing interference; in regard to the peri-implant, tobacco smoking can cause: systemic vasoconstriction, reduction in blood flow, greater probability to develop peri-implantitis and interference in post-surgery healing; the surgeon needs to verify if the patient is a smoker or not, in order to warn him about the risks that this habit may pose to his health and, consequently, to the treatments and oral rehabilitation work, which can lead to failure, since it is the periodontium that supports it; the patient must indicate that he is willing to give up the habit or not, and the dentist must record the warning given and the decision made thereafter, filing this document in the patient’s records in order to prevent any law suits concerning mal-practice.
88

Efeito do reuso sobre as características de superfície e da composição química de instrumentos de NiTi

Bastos, Mariana Mena Barreto 01 March 2016 (has links)
Submitted by Inês Marinho (bele_ballet@hotmail.com) on 2016-06-13T14:27:04Z No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-13T19:55:58Z (GMT) No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-06-13T19:59:05Z (GMT) No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) / Made available in DSpace on 2016-06-13T19:59:05Z (GMT). No. of bitstreams: 1 Dissertação - Mariana Mena Barreto Bastos.pdf: 12612062 bytes, checksum: ffcf9d6cbf1d42899081e2d03b967db4 (MD5) Previous issue date: 2016-03-01 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / Endodontic instruments NiTi were analyzed using a Scanning Electron Microscope (SEM) coupled to a Spectrometer X-ray by Energy Dispersive (EDAX), before and after use, in order to assess the presence of defects, deformations and analyze its chemical composition. To this end, thirty instruments were divided into 3 groups, 10 Protaper Next®X1 files (PNX1), 10 Protaper Next®X2 files (PNX2) and 10 WoveOne® files (WO), which were electromicrograph 250-fold increase in tip region, the tip of 2mm and 4mm. The instruments were used in the preparation of 60 simulated canals blocks made of polyester resin. Initially we performed the catheterization with K file # 10 and the length (CT), followed by instrumentation according to each group. Group 1: 10 blocks of simulated canals were instrumented with ProTaper NEXT® system using the file X1 to instrumentation of the cervical and middle third and X2 to the apical third. Group 2: 10 blocks were instrumented with the WaveOne® 25.08 Primary file system according to the manufacturer's recommendations. The instruments were first used one time and then reused 2 times, always in new simulated channels. The files were washed in ultrasonic tank and subjected to new microscopic analysis by SEM and EDAX. Then the elétromicrografias were taken at the tip of the instrument, the tip of 2mm and 4mm, with an increase of 250X. To establish the scores were observed the presence of jagged edges, grooves, wells and burrs. Each instrument when compared with each other in the same length over the three days of use showed no statistical difference in relation to the increase in defects (p> 0.05). Regarding the scores, statistical analysis of the results showed that only WO files showed a higher number of defects and deformations in the length of 4mm, the third time evaluation of the study (p <0.05). It has been observed in the analysis of the chemical elements that PNX1 files showed significant losses compared to the average Ni before use and after the third application (p <0.01); PNX2 the files and WO significant loss of Ni in the three days of use (p <0.01). Regarding Ti, PNX1 files in no significant loss during use (p> 0.05), but the files PNX2 showed significant loss between before and the first instrumentation and between the first and third use (p <0, 01). In WO files, a significant loss when compared before and after the first use and prior to the third use. Thus, reuse demonstrated that the instruments had all defects and deformations at some length and time of the study but not increased with use. Loss occurred only in ProTaper Ni NEXT® X1 files after use and the ProTaper files NEXT® X2 and WaveOne® was no loss of Ni and Ti after 3 uses. / Instrumentos endodônticos de NiTi foram analisados por meio de um Microscópio Eletrônico de Varredura (MEV) acoplado a um Espectômetro de Raio X por Energia Dispersiva (EDAX), antes e após o uso, com o objetivo de avaliar a presença de defeitos, deformações e analisar a sua composição química. Para isso, trinta instrumentos foram separados em 3 grupos, 10 limas ProTaper Next®X1(PNX1), 10 limas ProTaper Next®X2 (PNX2) e 10 limas WoveOne® (WO), as quais foram Elétromicrografados com aumento de 250 vezes, na região da ponta, 2mm e a 4mm da ponta. Os instrumentos foram utilizados no preparo de 60 blocos de canais simulados fabricados em resina poliéster. Inicialmente foi realizado o cateterismo com lima tipo K #10 e no comprimento de trabalho (CT), seguido pela instrumentação de acordo com cada grupo. Grupo 1: 10 blocos de canais simulados foram instrumentados com o sistema ProTaper Next®, utilizando a lima X1 para instrumentação do terço cervical e médio e a X2 para o terço apical. O grupo 2: 10 blocos foram instrumentados com a lima Primary 25.08 do sistema WaveOne® de acordo com as recomendações do fabricante. Os instrumentos foram utilizados primeiramente 1 vez e depois reutilizados 2 vezes, sempre em canais simulados novos. A limas foram lavadas em cuba ultrassônica e submetidas a nova análise microscópica pelo MEV e EDAX. Em seguida, as elétromicrografias foram tomadas na ponta do instrumento, a 2mm e a 4mm da ponta, com aumento de 250X. Para estabelecimento dos scores foram observados a presença de bordas irregulares, ranhuras, microcavidades e rebarbas. Cada instrumento quando comparados entre si no mesmo comprimento durante os três tempos de utilização não apresentaram diferença estatística em relação ao aumento dos defeitos (p>0,05). Em relação aos escores, a análise estatística dos resultados evidenciou que somente as limas WO apresentaram maior número de defeitos e deformações no comprimento de 4mm, nos 3 tempos de avaliação do estudo (p< 0.05). Foi observado na análise dos elementos químicos que as limas PNX1 apresentaram perdas significativas de Ni quando comparada as médias antes do uso e após a terceira utilização (p<0,01); nas limas PNX2 e WO houve perda significativa de Ni nos três tempos do uso (p<0,01). Em relação ao Ti, nas limas PNX1 não houve perda significativa ao longo do uso (p>0,05), porém, nas limas PNX2 apresentou perda significativa entre antes e a primeira instrumentação e entre o primeiro e terceiro uso (p<0,01). Nas limas WO, houve perda significativa quando comparamos antes e após a primeira utilização e antes com o terceiro uso. Assim, o reuso demonstrou que os instrumentos apresentaram todos os defeitos e deformações em algum comprimento e momento da pesquisa porém não aumentaram conforme o uso. Ocorreu perda apenas de Ni nas limas ProTaper Next® X1 após o uso e nas limas ProTaper Next® X2 e WaveOne® houve perda de Ni e Ti após as 3 utilizações.
89

Avaliação da eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos

Figueira, Keylla Lopes, 92-99211-2267 27 July 2018 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2018-09-13T13:11:58Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) / Made available in DSpace on 2018-09-13T13:11:58Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) dissertação final.pdf: 1572687 bytes, checksum: 674c29e0d0506fb0bcb429ddc3a7ef32 (MD5) Previous issue date: 2018-07-27 / FAPEAM - Fundação de Amparo à Pesquisa do Estado do Amazonas / This study evaluated in vitro the efficiency of used and adapted ultrasonic tips in the removal of metal retainers. Methods: Forty maxillary canines received Ni-Cr alloy fused metal retainers fixed with zinc phosphate cement. Group I - without ultrasonic vibration, Group II - with ultrasonic vibration using the ST – 09 new tip, Group III - with the ST - 09 used tip (used in 10 previous procedures) and Group IV - with ST – 09 adapted tip fitted with stone mounted. Groups II, III and IV received ultrasonic vibration for one minute with ENAC (Osada Eletric Co., Tokyo, Japan) at maximum frequency. The tensile test was performed on all specimens in the Universal Testing Machine with a speed of 1 mm/min, obtaining values in Newton, the data statistically analyzed using ANOVA and Tukey Test (p <0.05). RESULTS: The results showed statistically significant differences between the groups tested (control group = 472,641 N, new tip = 213,329 N, used tip = 408,185 N and adapted tip = 348,292 N). The lowest mean tensile strength was found in the group where the ultrasonic vibration was applied with the new tip followed by the adapted tip. The results show that the new tip reduces the tensile force required to remove the post cast. Conclusion: The change of the metallic structure of the ultrasonic tip interferes in the ultrasonic efficiency. / Este trabalho comparou in vitro a eficiência de pontas de ultrassom usada e adaptada na remoção de retentores metálicos fundidos. Métodos: Quarenta caninos superiores receberam retentores metálicos fundidos em liga Ni-Cr fixados com cimento de fosfato de zinco. Foram alocados em 4 grupos: Grupo I - sem vibração ultrassônica, Grupo II - com vibração ultrassônica utilizando a ponta ST - 09 nova, Grupo III - com a ponta ST - 09 usada (utilizada em 10 procedimentos anteriores) e Grupo IV - com a ponta ST – 09 adaptada com pedra montada. Os grupos II, III e IV receberam vibração ultrassônica por um minuto com aparelho ENAC (Osada Eletric Co., Tokyo, Japão) em máxima frequência (30 kHz). O teste de tração foi realizado em todos os espécimes na Máquina Universal de Ensaio com velocidade de 1 mm/min obtendo valores em Newton, os valores foram submetidos à análise estatística Anova e Teste Tukey (p<0.05). Resultados: Os resultados mostraram diferenças estatisticamente significantes entre os grupos testados (grupo controle = 472.641 N, ponta nova = 213.329 N, ponta usada = 408.185 N e ponta adaptada = 348.292 N). A menor média de força de tração foi encontrada no grupo que a vibração ultrassônica foi aplicada com a ponta nova, seguida da ponta adaptada. Os resultados evidenciaram que a ponta nova reduz a força de tração necessária para remoção dos retentores metálicos fundidos. Conclusão: A alteração da estrutura metálica da ponta ultrassônica interfere na eficiência ultrassônica.
90

Avaliação do comportamento mecânico e da microestrutura de duas marcas comerciais de zircônia monolítica 3Y-TZP sob influência de diferentes parâmetros de sinterização / Microstructural and mechanical evaluation of two commercial monolithic 3YTZP zirconia under various sintering conditions

Marcela Ferraz Catramby 21 March 2014 (has links)
Cerâmicas a base de zircônia para coroas e próteses fixas monolíticas prometem suprimir a vulnerabilidade ao lascamento de restaurações de múltiplas camadas, proporcionando estética e resistência mecânica simultâneas. No entanto, é possível que as alterações realizadas para maximizar suas propriedades óticas possam afetar a resistência mecânica. O presente estudo teve por objetivo comparar, com base na microestrutura, o comportamento mecânico de duas marcas comerciais de zircônias monolíticas a uma zircônia convencional para infraestruturas, observando ao mesmo tempo algumas variações nos parâmetros de sinterização. As zircônias monolíticas ceramill Zolid e Prettau e a zircônia convencional IPS e.max ZirCAD foram sinterizadas sob a temperatura preconizada pelos respectivos fabricantes, formando os grupos Z1450, P1600 e I1530. Adicionalmente, foram criados os grupos Z1530 e Z1600, representados pela zircônia ceramill Zolid submetida a ciclos modificados. Foram confeccionados 13 corpos de prova para cada grupo, os quais foram submetidos aos ensaios de difração de raios-x, densidade, análise do tamanho médio de grão e resistência à flexão em 4 pontos. Os espectros de difração revelaram a presença da fase tetragonal metaestável em todos os grupos antes e após a sinterização. Quanto à densidade, apresentou-se superior a 99% apenas nos grupos formados pelas zircônias Prettau e IPS e.max ZirCAD. O tamanho médio dos grãos permaneceu abaixo de 1m em todas as situações, sendo maior para o grupo P1600 (0,814m) e menor para o grupo Z1450 (0,463m). Embora tenha sido observada uma tendência de melhoria nos resultados sob taxa de aquecimento mais lenta, os grupos formados pela zircônia monolíticas ceramill Zolid obtiveram os valores mais baixos de confiabilidade (m=4,58 para Z1530) e de resistência mecânica (621,01±138,08MPa para Z1450). A zircônia Prettau apresentou valores de resistência mecânica mais altos e homogêneos (864,18±118,21MPa), contudo inferiores aos da zircônia convencional (1057,41±150,54MPa). Os resultados revelam que as zircônias monolíticas sob estudo possuem características microestruturais e propriedades mecânicas distintas das observadas para a zircônia convencional. / Monolithic zirconia ceramics for crown and bridge applications were designed to eliminate chipping trends of bilayered restorations, providing both aesthetic and mechanical strength. Nonetheless, it has been suggested that improvements in optical properties may affect the mechanical strength of these materials. The present study aimed to compare, based on a microstructural analysis, the mechanical behavior of two commercial monolithic zirconia ceramics with a conventional core zirconia material, as well as to verify sintering parameters modifications. Two monolithic zirconia ceramics (Ceramill Zolid and Prettau) and a conventional core zirconia material (IPS e.max ZirCAD) were sintered according to manufacturer´s recommendations, forming groups Z1450, P1600 and I1530. Extra groups, Z1530 and Z1600, were originated from ceramill Zolid zirconia specimens subjected to modified sintering cycles. The thirteen specimens that were manufactured for each group were submitted to x-ray diffraction analysis, density, average grain size determination and 4-point-bending tests. X-ray diffraction analysis revealed the presence of tetragonal metastable phase in all groups before and after sintering. Relative density found for Prettau and IPS e.max ZirCAD were greater than 99%. The average grain size remained below 1m for all groups. P1600 showed the largest grain sizes (0,814m) while Z1450 (0,463m) demonstrated the smallest ones. Groups originated from ceramill Zolid also presented the lowest Weibull modulus (m=4,58 for Z1530) and flexural strength results (621,01±138,08MPa for Z1450), regardless of non significant improvements that were achieved when using a low heating rate protocol. Prettau zirconia showed better mechanical behaviour and a more homogeneous distribution of results (864,18±118,21MPa), although lower than those of IPS e.max ZirCAD zirconia (1057,41±150,54MPa). Findings from this study show that the two commercial monolithic zirconia under analysis developed distinct mechanical properties and microstructural features from data established for conventional zirconia.

Page generated in 0.0653 seconds