• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 278
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 280
  • 199
  • 193
  • 137
  • 130
  • 125
  • 69
  • 33
  • 28
  • 24
  • 23
  • 23
  • 22
  • 21
  • 21
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Relacao entre prevalencia de carie, desenvolvimento social e provisao de servicos odontologicos no estado do Parana, Brasil, 1996

Pinto, Marcia Helena Baldani. January 2002 (has links) (PDF)
Mestre -- Escola Nacional de Saude Publica, Rio de Janeiro, 2002. / SAUDE PUBLICA.
42

Estabilidade da cor de agentes cimentantes utilizados para facetas cerâmicas

Pinto, Greciana Bruzi Brasil January 2010 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T09:08:50Z (GMT). No. of bitstreams: 1 282548.pdf: 2319327 bytes, checksum: c75a3f474f78a1d2071432b7a0fd88b5 (MD5) / O objetivo deste estudo in vitro foi avaliar a estabilidade da cor de diferentes agentes cimentantes. Quarenta incisivos bovinos foram selecionados e tiveram suas faces proximais, incisal e a raiz seccionadas e descartadas. Para simulação do preparo, foi realizado o desgaste do esmalte vestibular com lixa de SiC #200. Os espécimes foram, aleatoriamente, divididos em 4 grupos (n=10), de acordo com o agente cimentante: grupo 1, cimento resinoso fotopolimerizável (Variolink II/pasta base); grupo 2, cimento resinoso dual (Variolink II/pasta base e catalisadora); grupo 3, resina flow (Tetric Flow); e grupo 4, resina composta (4Seasons), todos na cor A3. Blocos de cerâmica Vita Mark II foram fatiados, em espessuras de 0,5mm, para simulação da faceta. A mensuração da cor foi realizada com espectrofotômetro (Easyshade) em 4 períodos: 1) previamente a fotoativação; 2) imediatamente, após a fotoativação; 3) 1 semana após cimentação e 4) após envelhecimento por termociclagem (5,000 ciclos a 5/55°C). Os . de Lab* não foram significativamente diferentes entre os grupos. Houve tendência crescente para +.L* (branco), +.a* (vermelho) e #.b* (azul) nos tempos analisados. Todos os grupos sofreram alterações significantes em .E (>3,3) durante os períodos avaliados. Os maiores valores foram observados com o cimento dual (.E=9,25) e os menores com o cimento fotopolimerizável (.E=4,49), ambos após envelhecimento, sendo estatisticamente significante. Os resultados revelaram que os agentes cimentantes apresentam tendência à alteração da cor no decorrer do tempo, sendo o cimento resinoso fotopolimerizável mais estável. / The purpose of this in vitro study was to evaluate the color stability of different cements agents. Forty bovine incisors were selected and had their proximal faces; incisor and the roots sectioned and then got rid of them. To simulate the preparation the vestibular flat enamel was prepared using sand paper # 200. The specimens were randomly divided into four groups (n=10), according to the cement agent used: Group 1, photo polymerized cement agent (Variolink II / basic paste); Group 2, dual cement resin (Variolink II /paste and cataliser); Group 3, flow resin (Tetric Flow); and Group 4; composite resin (4Seasons) all in the color A3. Porcelain blocks Vita Mark II were sliced into 0.5mm thickness to simulate veneers. The color measurement was done by the spectrophotometer (Easy shade) in four periods: 1) before photo activation; 2) immediately after photo activation; 3) one week after cementation and 4) after aging by thermo cycling (5.000 cycles at 5/55°C). The Lab* unities were not significantly different among groups. There was an increasing tendency to +ÄL* (white), +Äa* (red) and #Äb* (blue) in the analyzed times. All groups suffered significant changes in ÄE (>3.3) during the evaluated periods. The higher values were observed in the dual cement (ÄE=9.25) and the lower in the photopolymerizable cement (ÄE= 4.49), both after aging, been statistically significant. The results showed that the cement agents had a tendency to alter the color with the time, been the photopolymerizable cement resin more stable.
43

Influência de alterações na rugosidade superficial externa e interna na resistência flexural de uma cerâmica

Ruschel, Vanessa Carla January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T03:14:18Z (GMT). No. of bitstreams: 1 301712.pdf: 15345261 bytes, checksum: cc4e7476df0b3a288b9fe6b32229edc4 (MD5) / O objetivo deste trabalho foi avaliar o efeito do ajuste externo por meio de desgaste simulado, efetuando ou não o polimento, e do ajuste interno na rugosidade e resistência flexural de uma cerâmica vítrea reforçada com dissilicato de lítio. Para tanto, foram confeccionados 60 espécimes em forma de barra (? 20 x 4 ± 0.25 x 1.2 ± 0.2 mm) da cerâmica IPS e.max Press (Ivoclar Vivadent) e divididos em 6 grupos (n=10): G1 - glaze (controle); G2 - ajuste externo (AE); G3 - AE + polimento; G4 - ajuste interno (AI); G5 - AE + AI; G6 - AE + polimento + AI. Em seguida, o Ra dos espécimes foi mensurado com Rugosímetro. Após 24 h de armazenamento em água destilada a 37?C, os espécimes foram submetidos ao teste de resistência flexural de três pontos. Foi utilizada uma amostra de cada grupo (n=1) para análise da morfologia superficial em Microscópio Eletrônico de Varredura (MEV). Os resultados foram analisados por meio dos testes ANOVA one-way, Bonferroni e Dunnett. As Médias Aritméticas e Desvio-Padrão (±DP) obtidos no teste de resistência flexural, em MPa, foram: G1=194.41 (±33.54); G2=224.96 (±31.67); G3=194.27 (±31.21); G4=193.37 (±24.39); G5=191.04 (±28.01); G6=188.62 (±27.3). As médias de Ra (µm) e Desvio-Padrão (±DP) foram: G1=1.26 (±0.21); G2=1.16 (±0.75); G3=0.71 (±0.21); G4=1.26 (±0.21); G5=1.03 (±0.23); G6=0.86 (±0.20). O ajuste externo sem o polimento não interferiu a rugosidade superficial da cerâmica, porém quando seguido desse procedimento, houve uma redução significativa. Em qualquer das duas situações, a rugosidade não influenciou a resistência flexural. Da mesma forma, o ajuste interno e a associação dos procedimentos não interferiram na resistência flexural.
44

Avaliação clínica da intensidade da força máxima friccional dos contatos proximais de restaurações diretas e indiretas em dentes posteriores

Stolf, Sheila Cristina January 2011 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T04:52:29Z (GMT). No. of bitstreams: 1 300453.pdf: 314520351 bytes, checksum: 33a6b2f61f87a1bf9e9d6b1f6cb12ae0 (MD5) / O objetivo deste trabalho clínico é determinar e comparar o contato proximal estabelecido por restaurações diretas e indiretas do tipo mésio-oclusodistais (MOD) em dentes posteriores. Selecionaram-se 36 pacientes, os quais receberam restaurações diretas de resina composta ou indiretas de cerâmica. As restaurações foram confeccionadas com o sistema adesivo Scotchbond Multi-Purpose e resina composta FiltekTM Z350 (n=18) e com cerâmica injetável IPS e.max Press (n=18). Os contatos proximais foram mensurados por meio do aparelho Medidor de Pressão Dental (TPM), antes do tratamento e 48 h após a confecção das restaurações entre os contatos proximais, mesial e distal, do dente restaurado e os do dente adjacente (CPMR e CPDR, respectivamente), assim como o contato proximal mesial do dente adjacente à restauração (CPM). Como controle, mensuraram-se os contatos proximais no lado contralateral, nas mesmas posições de mensuração. Após a realização das ANOVAs ou ANCOVAs, utilizou-se o Teste post hoc de Bonferroni. A comparação dos valores iniciais e finais da força máxima friccional (FMF) em cada grupo, para cada posição, foi realizada por meio do Teste t de Student (p?0,05). Para os valores finais de FMF entre os grupos verificou-se que na posição de contato proximal distal do dente restaurado (CPDR) as médias obtidas no grupo submetido ao tratamento restaurador com cerâmica e as do grupo controle foram consideravelmente diferentes, porém não diferiram naqueles contatos submetidos à resina composta. Quanto à posição contato proximal mesial (CPMR and CPM), independentemente do local de mensuração, verificaram-se diferenças estatísticas significativas entre todos os grupos (p<0,001), com destaque para a cerâmica. Portanto, a FMF do contato proximal promovido pelas restaurações diretas e indiretas variou, respectivamente, na posição mesial do dente restaurado entre 1,53 N e 2,70 N e entre 1,47 N e 5,07 N, e na posição distal restaurada, de 1,63 N a 2,07 N e de 1,03 N a 4,50 N. As restaurações cerâmicas promoveram contatos proximais mais justos em relação às resinas compostas. Ainda, as restaurações aumentaram a FMF do contato proximal mesial do dente adjacente à restauração, entretanto nos contatos proximais do lado contralateral constatou-se pouca interferência
45

A influência de diferentes técnicas e sistemas de cimentação na resistência de união de uma cerâmica reforçada por leucita à dentina

Rodrigues, Eduardo Roberty Coutinho January 2008 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-24T05:42:00Z (GMT). No. of bitstreams: 1 264430.pdf: 4411827 bytes, checksum: 5c903963b4c58e655ba474c113f6e1cf (MD5) / O objetivo deste estudo in vitro foi testar a hipótese de que diferentes técnicas e sistemas de cimentação influenciam na resistência de união de uma cerâmica reforçada por leucita à dentina, através do teste de microtração. Vinte e sete terceiros molares humanos tiveram a superfície dentinária média exposta de forma plana, através de uma secção transversal realizada com um disco diamantado. O substrato restaurador foi uma cerâmica reforçada por leucita (ProCad) com 3mm de espessura. Três técnicas de cimentação foram aplicadas: C, onde o sistema adesivo não foi fotoativado antes do assentamento da cerâmica; P, na qual o sistema adesivo foi fotoativado antes do assentamento da cerâmica; e S, onde foi realizado o chamado selamento dentinário imediato, no qual o adesivo é aplicado antes da temporização, e novamente na cimentação. Cada técnica foi realizada com 3 sistemas de cimentação: OP, utilizando o adesivo Optibond FL e o cimento resinoso dual Nexus 2; SB, em que foram utilizados o adesivo Adper Single Bond 2 e o cimento resinoso dual Rely X ARC; e CF, utilizando o adesivo Clearfil SE e o cimento resinoso dual Panavia F. Após uma semana de temporização, os procedimentos de cimentação foram realizados e os dentes cimentados foram armazenados em água destilada por 24h a 37ºC. Os elementos dentais foram preparados para serem submetidos ao teste de microtração, sendo realizados cortes nos eixos "X" e "Y" para a obtenção de filetes retangulares com área de secção transversal de 0,64mm2. Os filetes foram tracionados em uma máquina de ensaios universal (Instron). Os padrões de fratura de todos os filetes foram analisados no MEV. O teste estatístico Anova dois critérios seguido do teste de comparações múltiplas de Tukey indicou que a técnica (p < 0,01) e o sistema de cimentação (p < 0,01) influenciam na resistência de união da cerâmica à dentina. Quase que a totalidade das fraturas aconteceu dentro da interface adesiva. De acordo com os resultados pode-se concluir que a hipótese foi totalmente aceita, e que a técnica e o sistema de cimentação devem ser analisados em conjunto. A fotopolimerização do adesivo, em conjunto com o cimento resinoso, após o assentamento da cerâmica, é recomendada para a obtenção de uma resistência de união mais alta da cerâmica à dentina. The aim of this in vitro study was to test the following hypothesis: different cementation techniques and systems affect microtensile bond strength between dentin and a leucite reinforced ceramic. Twenty-seven human third molars were prepared for bonding by removing the occlusal surface. A medium depth flat dentin were exposed after performing a transversal section. The restorative substrate was a 3mm thick leucite reinforced ceramic (Pro Cad). Three cementation techniques were applied: C - adhesive system was not photopolymerized before ceramic setting; P - adhesive system was photopolymerized before ceramic setting and S - immediate dentin sealing was performed, which the adhesive system is applied before temporization and at cementation. Each technique was performed using three cementation systems: OP - Optibond FL adhesive system and Nexus 2 dual resin cement; SB - Adper Single Bond 2 adhesive system and Rely X ARC dual resin cement and CF - Clearfill SE adhesive system and Panavia F dual resin cement. After one-week temporization, the cementation procedures were performed. The cemented teeth were stored in distilled water for 24 hours at 37 degrees C. For microtensile bond test, the dental elements were longitudinally sectioned in both "X" and "Y" directions in order to obtain rectangular sticks with an approximately 0.64mm2 cross-sectional área. The sticks were fractured on a universal tests machine (Instron). Fracture patterns of all sticks were analyzed by scanning electronic microscopy (SEM). Statistical test Anova two-way followed by Tukey multiple comparisons test revealed that the cementation technique and system affect microtensile bond strength between dentin and ceramic. Almost all fractures occurred at the adhesive interface. According to the results, it can be concluded that the hypothesis was totally accepted. Almost the entire fractures occured within the adhesive interface. It was concluded that the cementation technique and system must be analyzed together. Co-polimerization between the bonding resin and the luting cement, after the seatting of the restauration is advised in order to achieve higher bond strength between ceramic and dentin.
46

Estudo comparativo entre análise cefalométrica radiográfica e exame polissonográfico para diagnóstico da síndrome da apnéia obstrutiva do sono

Silva, Emerson Luiz Costa da January 2001 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T16:56:19Z No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:02:03Z (GMT) No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) / Made available in DSpace on 2013-05-16T18:02:03Z (GMT). No. of bitstreams: 1 Dissertação Emerson Silva.pdf: 465656 bytes, checksum: 731640379127dce40ab114cd303d074c (MD5) Previous issue date: 2001 / O objetivo deste estudo foi comparar a eficiência do exame cefalométrico radiográfico em relação ao exame polissonográfico para o diagnóstico da Síndrome da Apnéia Obstrutiva do Sono (SAOS), em 60 pacientes com suspeita clínica da condição. Observou-se a confiabilidade dos dados obtidos na cefalometria, vez que esta vem sendo utilizada largamente no protocolo de exame de pacientes apnêicos, principalmente para a determinação dos sítios obstrutivos, servindo desta forma de guia terapêutico. Os resultados demonstraram não haver diferença estatisticamente significante no que diz respeito à capacidade diagnóstica da cefalometria radiográfica e do exame polissonográfico. A cefalometria radiográfica mostrou-se capaz de diagnosticar, satisfatoriamente, indivíduos portadores de SAOS (sensibilidade ? 91,5%). Por outro lado, a cefalometria radiográfica não se mostrou capaz em identificar, de forma satisfatória, indivíduos não portadores de SAOS (especificidade ? 38,5%). Por fim, como a cefalometria radiográfica apresentou alta sensibilidade na determinação dos sítios obstrutivos, concluímos que tal exame deve compor um protocolo, em associação ao exame polissonográfico, de procedimento diagnóstico para indivíduos portadores de SAOS. / Salvador
47

Influência de diferentes técnicas e agentes de cimentação na resistência adesiva da cerâmica à dentina

Espina, Lívia Teichmann 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2009 / Made available in DSpace on 2012-10-24T07:01:24Z (GMT). No. of bitstreams: 1 269325.pdf: 43957859 bytes, checksum: 50a1cc87dd34a036408e04bbbbbc9614 (MD5) / Este estudo teve como objetivo avaliar a influência da técnica de cimentação e do uso de agentes adesivos com e sem carga na resistência de união de pastilhas cerâmicas à dentina humana, através do teste mecânico de microtração. Para tanto, 18 terceiros molares hígidos tiveram a superfície de esmalte oclusal seccionada, a dentina planificada, e foram divididos conforme a técnica de cimentação, em: 1- Sem pré-polimerização do adesivo, que foi polimerizado simultaneamente ao cimento resinoso; 2- Com pré-polimerização do adesivo, antes da aplicação do cimento resinoso; 3- Selamento Dentinário Imediato, cujas amostras receberam uma aplicação do adesivo previamente à cimentação da restauração provisória. Cada grupo foi subdividido de acordo com o sistema de cimentação empregado: Optibond FL/Nexus2 (Kerr) ou Scotchbond Multi- Purpose/RelyX ARC (3M ESPE). Após 7 dias, correspondente à fase de temporização, pastilhas cerâmicas (ProCad, Ivoclar Vivadent) foram cimentadas. O teste de microtração foi realizado após 24h de armazenagem em água destilada. As superfícies fraturadas foram analisadas em MEV para determinação do padrão de fratura. A análise estatística identificou que a técnica de cimentação Sem prépolimerização do agente adesivo apresentou o maior valor de resistência adesiva à microtração, podendo ser realizada com ambos os sistemas adesivos testados.
48

Influência do desenho da cavidade na microinfiltração marginal de restaurações cerâmicas tipo MOD

Kina, Mônica January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-22T12:01:34Z (GMT). No. of bitstreams: 1 234066.pdf: 1169220 bytes, checksum: 7b61e6d5f84afb7e5b54cc521b7f24e2 (MD5) / O objetivo deste estudo foi avaliar a influência do desenho da cavidade na infiltração marginal de inlays cerâmicos.Foram confeccionados 30 cavidades classe II (MOD) em pré-molares, com término gengival mesial em esmalte e distal em dentina, obtendo-se as seguintes características: Grupo I: cavidades com divergência de 12º; Grupo II:cavidades com divergência de 18º; Grupo III:cavidades com divergência de 24º.Os inlays cerâmicos de IPS-Empress foram cimentados de acordo com as instruções do fabricante e submetidos ao teste de termociclagem. Após os testes estatísticos, concluiu-se que as divergências das paredes das cavidades, bem como a localização das margens (esmalte ou dentina) influenciam a microinfiltração de inlays cerâmicos confeccionados como sistema IPS-Empress. This in vitro study evaluates the influence of the cavity design on the microleakage of IPSEmpress ceramic inlays. Thirty extracted human bicuspids were selected and stored at room temperature. The specimens were randomly ascribed to three groups (n=10). Class II (MOD) cavities with gingival margins in enamel and dentin were prepared: Group I # 12° divergent walls; Group II - 18° divergent walls; Group III - 24° divergent walls. After the impressiontaking, IPS Empress® inlays (Ivoclar Vivadent) were fabricated according with the manufacturer#s instructions. The teeth were thermocycled (500 cycles, 5° to 55°C), sealed with nail varnish, immersed in a 0.5% basic fuchsin solution for 24 hours, embedded in epoxy resin, and cut in a mesio-distal direction. The sections were evaluated using a linear quantitative method (in mm) by three previously calibrated evaluators which used a software (ImageTool, San Antonio, TX, EUA). The results were statistically analyzed using one-way ANOVA and paired T-test. It was concluded that the walls divergence did not influence the degree of microleakage. Group I presented the highest microleakage values (p=0.0001), and Groups II and III did not present statistically significant differences (p=0.0022). Regarding the location of the gingival margin (enamel or dentin), the highest values were observed for dentin margins (p<0.0001). None of the groups was capable to reduce completely the marginal leakage.
49

Reparo de cerâmica com resina composta

Malta, Daniel Alexandre Menezes Pedrosa January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-26T11:58:31Z (GMT). No. of bitstreams: 1 302032.pdf: 21046556 bytes, checksum: 24fa316ee4eca8d1e29914229da6264d (MD5) / A atual pesquisa objetivou encontrar a força de união ao cisalhamento do reparo de resina composta à cerâmica feldspática empregando três tratamentos de superfície com laser de Nd:YAG em comparação com quatro tratamentos convencionais. Três blocos de cerâmica para CAD/ CAM (IPS Empress CAD) foram cortados em 77 blocos menores com 2 mm de largura e 2 mm de profundidade. Estes foram incluídos em resina acrílica e as superfícies foram delimitadas com uma fita adesiva com um orifício central de 3 mm de diâmetro. Os tratamentos de superfície foram feitos de acordo com os seguintes Grupos (n=10): A - rugosidade com ponta diamantada mais ácido fosfórico; B - condicionamento com ácido hidrofluorídrico; C - jateamento com partículas de Al2O3 com 50 µm; D - jateamento com partículas de sílica com 30 µm; E - laser de Nd:YAG com pó de carbono; F - laser de Nd:YAG com pó de sílica; G - laser de Nd:YAG com pó de sílica mais condicionamento com ácido hidrofluorídrico. Silano (Monobond - S) seguido do adesivo (Tetric N-bond) foi aplicado após os tratamentos de superfície. O Grupo D recebeu um silano (ESPE-SIL) e um adesivo (Vision Bond) diferentes. As amostras foram reparadas com resina composta (Tetric N-ceram) usando uma matriz metálica. O adesivo Nbond foi fotopolimerizado por 10 segundos e o Vision Bond por 20 segundos. As camadas de resina composta foram fotopolimerizadas por 20 segundos. As amostras de cerâmica-resina foram estocadas em água destilada por 48 horas. Os espécimes foram então submetidos a força de cisalhamento por meio de uma máquina de ensaios universais - Instron. Após os testes, as amostras fraturadas foram armazenadas para posterior análise do modo de falha por microscopia óptica. Uma amostra de cada Grupo e uma amostra sem tratamento de superfície não receberam os procedimentos adesivos restauradores e foram empregados para análise morfológica por microscopia eletrônica de varredura. Os dados dos testes de cisalhamento foram submetidos à análise de variância - ANOVA, seguido pelo teste de Tukey. Os resultados mostraram que a força de união ao cisalhamento do Grupo B foi 16,59 MPa, significativamente mais alta do que os demais Grupos. Os tratamentos com laser evidenciaram as menores médias (Grupo E - 3,87; Grupo F - 4,39; Grupo G - 7,41 MPa). O Grupo A alcançou 7,89 MPa, estatisticamente similar aos Grupos com laser. Os Grupos C e D foram estatisticamente similares com 10,01 e 11,42 MPa, respectivamente. Os modos de falha relatados foram do tipo adesivo e misto. A análise morfológica revelou coerência com os dados de força de união coletados. Foi determinado que o condicionamento com ácido fluorídrico rendeu melhor força de união ao cisalhamento. / The present research was reasoned in achieve the shear bond strength of a composite resin repair to a feldspathic ceramic using three Nd:YAG laser surface treatments in comparison with four conventional ways. Three ceramic blocks for CAD/CAM (IPS Empress® CAD) were cut in 77 smaller blocks with 2-mm width and 2-mm depth. Those blocks were included in acrylic resin and the surfaces were delimited with an adhesive tape with a hole of 3-mm diameter. The surface treatments were done in agreement with the following Groups (n=10): A - roughening with a diamond bur + phosphoric acid; B - etching with hydrofluoric acid; C - sandblasting with 50-ìm Al2O3; D - sandblasting with 30-ìm silica; E - Nd:YAG laser with carbon powder; F - Nd:YAG laser with 30-ìm silica; G - Nd:YAG laser with 30-ìm silica + etching with hydrofluoric acid. Silane (Monobond - S) followed by the adhesive (Tetric N-bond) was applied after the surface treatments. Group D received a different silane (ESPE-SIL) and adhesive (Vision Bond). The samples were repaired with composite resin (Tetric N-ceram) using a metal matrix. N-bond adhesive was lightpolymerized for 10 seconds and the Vision Bond for 20 seconds. Composite resin layers were lightpolymerized for 20 seconds. The ceramic-resin samples were stored in distilled water for 48 hours. The specimens were then subjected to a shear force via an Instron Machine. After testing, the fractured samples were stored for posterior analysis of the failure mode by optical microscopy. One sample of each Group and one more sample with no surface treatment did not receive the restorative procedures and were used for morphological analysis by scanning electron microscopy. The shear bond strength data was submitted to one-way ANOVA followed by Tukey test. The results showed that the shear bond strength to Group B was 16,59 MPa, significantly higher than those others Groups. The laser treatments showed the lowest averages (Group E - 3,87; Group F - 4,39; and Group G - 7,41 MPa). Group A reached 7,89 MPa, statistically similar to the laser Groups. Groups C and D were statistically similar with 10,01 and 11,42 MPa, respectively. The failure modes reported were adhesive and mixed. The morphological analysis were coherent with the bond strength data collected. It was determined that the etching with hydrofluoric acid yielded better shear bond strength.
50

Influência do número de faces (OD e MOD) e localização da margem gengival em esmalte ou em dentina na infiltração marginal de inlays cerâmicos

Cardoso, Paula de Carvalho January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T18:02:10Z (GMT). No. of bitstreams: 1 202862.pdf: 1700824 bytes, checksum: 520d9f5da7f8622f83acaa603d99430d (MD5) / O estudo avaliou a influência do número de faces e localização da margem gengival na infiltração marginal de inlays cerâmicos. Quarenta pré-molares foram divididos em 4 grupos com 10 dentes cada. No grupo I - MOD, com parede gengival da caixa proximal localizada 1mm aquém da JAC; no grupo II - OD, com margem 1mm aquém da JAC; no grupo III -MOD, com margem gengival 1mm abaixo da JAC e no grupo IV - OD, com margem 1mm abaixo da JAC. Após a moldagem e confecção dos inlays cerâmicos de IPS Empress, os espécimes foram preparados para avaliação da microinfiltração. Conclui-se que os maiores valores de infiltração do corante foram encontrados quando margem gengival localizava-se em dentina. Não houve diferença entre os grupos com diferentes tipos de preparos (DO e MOD).

Page generated in 0.0595 seconds