• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 23
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 23
  • 12
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Antropologia física = arcadas dentárias / Physical anthropology : dental arches

Sassi, Carlos, 1963- 17 August 2018 (has links)
Orientador: Eduardo Daruge Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:37:02Z (GMT). No. of bitstreams: 1 Sassi_Carlos_M.pdf: 1811028 bytes, checksum: 6b42102cdba527205f539284d164e7f1 (MD5) Previous issue date: 2011 / Resumo: A necessidade de identificação para a humanidade tem a sua origem na própria natureza social do homem e nos seus irredutíveis anseios de diferenciar-se dos seus semelhantes. Assim sendo e em virtude das mudanças evolutivas acontecidas nas organizações coletivas que ele integra, não pode surpreender que, nos dias atuais, exista uma notória exigência nesse sentido, dos âmbitos sociais, civis, administrativos, comerciais e penais. Nesse contexto, a determinação do gênero constitui um dos objetivos principais dos peritos médicolegistas e odontolegistas, quando responsáveis pelo exame antropológico de ossadas humanas. No presente estudo, foram utilizados 112 modelos inferiores de gesso ortodôntico tipo 3, correspondentes a igual número de pacientes, 56 do gênero masculino e 56 do feminino, assistidos na Clínica de Ortodontia do IUCEDDU, Instituto Universitario Centro de Estudio y Diagnóstico de las Disgnacias del Uruguay, localizada na cidade de Montevidéu, com idades compreendidas entre 21 e 60 anos, com o objetivo de estabelecer um método confiável para a determinação do gênero, por meio de medidas realizadas nas arcadas dentárias e aplicar as citadas à antropologia forense, como ferramentas de auxílio nos processos de investigação ou identificação. Constatou-se que das medidas e cálculos efetivados (largura mésio-distal e distância gengivo-incisal do 33 e 43; distância intercanina; índice mandibular canino; área do triângulo formado pelos segmentos A, C e B - compreendidos entre os pontos mais proeminentes na união das faces vestibular e distal dos dentes 36 e 46 e o ponto interincisivo, e a distância entre os pontos definidos para as peças 36 e 46-, e altura do mesmo - segmento H, perpendicular a B que passa pelo ponto interincisivo -), só se mostraram significativamente dimórficas a largura mésio-distal e distância gengivo-incisal do 43 e a área do triângulo. Obteve-se um modelo de regressão logística para determinar o gênero, com um grau de confiabilidade de 72,3% e uma árvore de classificação e regressão, com um de 77,7%. Concluiu-se que há possibilidades de aplicar os citados dados à antropologia forense, como ferramentas de auxílio nos processos de investigação ou identificação / Abstract: Human identification requirement has its origin in social nature of man and its irreducible wishes to differentiate itself from its peers.Therefore and in front of social evolutionary changes that happened in collective organizations, it's no wonder that nowadays, there is a noticeable demand in this sense, from social, civil, administrative, commercial and criminal areas. In this context, gender determination is a major goal of forensic medical and odontologic experts, when responsibles for anthropology examination of human remains. In this study, were used 112 inferior dental stone casts, type 3 orthodontic, of 112 patients (56 males, 56 females), assisted in the Clinic of Orthodontics IUCEDDU, Instituto Universitario Centro de Estudios y Diagnóstico de las Disgnacias del Uruguay, located in Montevideo, aged between 21 and 60 years. The aim of this research was to establish a reliable method for gender determination by means of dental arch measurements and to use them in forensic anthropology, simplificating investigation or identification process. Several measurements and calculations were made effective, such as mesiodistal width and gingivo-incisal distance of both mandibular canines (33 and 43), intercanine distance (space between the cusps of the same teeth), mandibular canine index (ratio between mesiodistal width and canine arch width or intercanine distance), area of the triangle bounded by the segments A (from the most proeminent point of the angle formed by the tangents of the buccal and distal faces of the left first molar, to the interincisor point), C (from the most proeminent point of the angle formed by the tangents of the buccal and distal faces of the right first molar, to the interincisor point), and B (the distance between the same points of the first molars), and segment H (height or altitude of the triangle, perpendicular to B, passing through interincisor point). It was observed significant sexual dimorphism only at the mesiodistal width and gingivo-incisal distance of right canine (43), and the area of the triangle. The authors obtained a logit regression model to determine the gender with a degree of reliability of 72,3% and a classification and regression tree with a reliability rate of 77,7%. It was concluded that these data can be applied in forensic anthropology, as auxiliary tools in the investigation or identification process / Mestrado / Odontologia Legal e Deontologia / Mestre em Biologia Buco-Dental
12

Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators

Baldi, Járcio Victório 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
13

Afinidades biológicas extra-continentais dos paleoíndios tardios de Lagoa Santa e suas implicações para a questão do povoamento do novo mundo: uma abordagem odontométrica / Extra-continental biological afinities among Late Paleoindian of Lagoa Santa, Central Brazil, and its implications for the settlement of America: an odontometric view

Nunes, Tatiana Leite 17 March 2010 (has links)
Atualmente, quatro principais modelos discutem o Povoamento da América. O mais antigo defende a entrada de três levas migratórias (Greenberg et al., 1986), outro modelo, duas (Neves et al., 1989), o modelo genético, apenas uma (Bonatto & Salzano, 1997) e, recentemente, Gonzalez-José et al. (2008) apresentaram um modelo de fluxo continuo. O presente trabalho investigou as afinidades biológicas de uma população paleoíndia brasileira, a de Lagoa Santa, com antiguidade estimada entre 11.500-7.500 A.P., comparando-a a outras populações mundiais (Banco de Dados Hanihara). A investigação baseou-se em análise odontométrica (diâmetros dentários mesiodistais e bucolinguais). Os dentes apresentam alta herdabilidade, morfogênese estável, grande representatividade arqueológica e são pouco influenciados por fatores ambientais imediatos. As afinidades biológicas dos paleoíndios de Lagoa Santa foram exploradas por Análise Multivariada, com a aplicação de Análise de Componentes Principais e Matrizes de Dissimilaridade (Euclidianas e Mahalanobis), estas últimas visualizadas por Análises de Cluster e de Escalonamento Multidimensional. Diferentes sets de análises foram realizados, para ambos os sexos considerando-se tamanho e forma e somente forma. Os resultados apresentados demonstram uma forte tendência de diferenciação da população de Lagoa Santa em relação às populações nativas americanas tardias e atuais, associando-se mais fortemente com Polinésios e Sudeste Asiáticos. Estes resultados questionam a homogeneidade dos nativos americanos e apóiam fortemente o modelo dos Dois Componentes Biológicos Principais (Neves et al., 1989). / Nowadays, four principal models discuss the settlement of the Americas. The oldest one defends three waves into the continent (Greenberg et al, 1986), other model, two (Neves et al., 1989), the gentic one, only one (Bonatto & Salzano, 1997), and recently, Gonzalez et al. (2008) presented a continuous flow model. The present study investigated the biological affinities of a Paleoindian Brazilian population, Lagoa Santa, with estimated antiquity between 11500-7500AP, comparing them to others word populations (Hanihara Data Bank). The investigation was based on odontometry data (mesiodistal and bucolingual diameters). Teeth have high heritability, stable morphogenesis, high archaeological presence, and are little influenced by immediate environmental factors. The biological affinities of Lagoa Santa Paleoindians were explored by Multivariate Analyses, with the application of Principal Components Analysis and Matrix Dissimilarities (Euclidian and Mahalanobis), the later visualized by Cluster Analysis and Multidimensional Scaling. Different sets of analysis were carried out for both sexes considering size and shape and shape alone. The results point to a strong tendency of differentiation of the Lagoa Santa population in relation to other Native Americans, and a strong association with Southeast Asians and Polynesians. The results strongly support the Two Main Biological Components Model (Neves et al., 1989).
14

"Validação das ferramentas de calibragem de medidas em três sistemas de radiografia digital" / Assessment of calibration tools of three digital radiography systems

Girondi, José Raul 30 March 2006 (has links)
O desenvolvimento tecnológico busca fatores que possibilitem uma menor exposição do paciente e profissional aos raios ionizantes, maior agilidade no atendimento ao paciente e maior auxilio no desenvolvimento do diagnóstico final. Assim a associação entre informática e radiologia básica, traduzidas como radiologia digital, fez-se conseguir os fatores buscados. Uma ferramenta dos sistema digitais é a calibração prévia às medidas. Com essas observações avaliamos tais ferramentas de três sistemas de radiografias digitais, objetivando validar e comprovar sua eficácia nas metodologias dos trabalhos presentes e futuros. Para tanto utilizamos 20 dentes humanos secos provindos do Banco de Dentes Permanentes da FOUSP, os quais foram radiografados com o auxílio de três sistemas de radiografia digital, direto e semidireto (Digora, RVG Trophy e Visualix). O padrão ouro das medidas dos dentes foi a verificação das dimensões dos dentes por meio de um paquímetro digital e posteriormente comparados os seus padrões de medidas com os softwares dos respectivos sistema. Os resultados foram analisados estatisticamente pelo ANOVA (métodos de Tukey e Dunnett), chegando às seguintes conclusões: existe diferença significante entre os aparelhos p<0,001; a média das medidas obtidas houve diferença significante (p<0,001) com o aparelho Digora foi menor que as médias obtidas com os aparelhos das marcas Visualix e RVG; considerando-se o padrão A e o padrão B de calibragem, não existe diferença estatística significante entre os avaliadores; considerando-se a calibragem sem padrão, um dos avaliadores obteve média mais elevada que os demais avaliadores no caso das medidas realizadas com o aparelho Digora, porém este fato não se repetiu quando da utilização dos outros aparelhos; comparando-se as medidas de referência (paquímetro) observa-se que mais uma vez o aparelho Digora (padrão A, padrão B e sem padrão) apresentou diferença significativa; os aparelhos das marcas Visualix e RVG não mostraram diferenças significativas quando comparados com o valor de referência. / Technological development aims at reducing exposure of both the professional and the patient to ionizing radiation, improving patient treatment and aiding final diagnosis. The combination of computer technology and radiology, i.e. digital radiography, has made this possible. One of the tools of digital radiography systems is calibration prior to measurement. The purpose of this study was to assess the calibration tools of three digital radiography systems to verify their efficacy. Twenty human teeth obtained from the Human Teeth Bank of the School of Dentistry, University of São Paulo, were used. The dry teeth were radiographed using three different direct digital radiography systems Digora, RVG Trophy and Visualix. The measurements of the teeth obtained with a digital caliper were considered the gold standard. These measurements were later compared with those obtained using the digital systems. The results were submitted to ANOVA (methods of Tukey and Dunnett), and the following conclusions were drawn: there was a significant difference between the systems used (p < 0.001); the averages of the measurements obtained with the three systems were significantly different (p<0,001). Visualix and RVG were more accurate than Digora considering A and B calibration standards, no significant difference was observed between the examiners; when there was no calibration standard and the Digora system was used, one examiner obtained more high averages measurements than the others; when there was no calibration standard and Visualix or RVG systems were used, no differences were observed between the examiners; the measurements obtained with Digora system (standards A, B or no standard) were statistically different from the gold standard the measurements obtained with Visualix and RVG systems presented no significant difference when compared with the gold standard.
15

Estudo cl?nico da acur?cia da localiza??o eletr?nica na constri??o apical e respectiva concord?ncia radiogr?fica / Clinical study of the accuracy of electronic location in constriction apical and their respective radiographic agreement

Fernandes, Vanessa Cruz Silva 29 August 2014 (has links)
Submitted by Nivaldo Melo (nivaldo.melo@ufvjm.edu.br) on 2015-11-19T16:55:42Z No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-11-19T17:53:53Z (GMT) No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-11-19T17:53:54Z (GMT). No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2014 / Introdu??o: Terapeuticamente a constri??o apical ? refer?ncia do comprimento de trabalho (CT) dos canais radiculares (CR). Objetivo: Avaliar clinicamente fatores associados ? acur?cia do localizador apical eletr?nico (LAE) Apex Finder A.F.A. 7005 na determina??o da constri??o apical. Metodologia: Para cada CR, uma lima tipo Kerr selecionada e acoplada ao LAE foi inserida intracanalmente at? obter est?vel marca??o, 1 mm no painel digital (LCD). Na radiografia periapical correspondente ? dist?ncia da ponta da lima ao v?rtice dent?rio foi categorizada como precisa (0.5 a 1.5 mm), aceit?vel (0 a 2 mm) ou imprecisa (demais medidas). A concord?ncia foi analisada em fun??o do grupo de dentes, estado pulpar e periapical, di?metro do CR e di?metro da lima explorat?ria. A influ?ncia das vari?veis independentes foi analisada pelos testes Mann-Whitney, Kruskal-Wallis e Correla??o de Sperman (p<0,05). Resultados: Os dentes anteriores (n=21), pr?-molares (n=20) e molares (n=33) proveram 147 CR, dos quais 43.5% eram atr?sicos. Em 102 (69,4%) a polpa estava necr?tica, dentre os quais 70 (47,6%) apresentavam radiolucidez periapical. Obteve-se elevada concord?ncia entre a medida eletr?nica e radiogr?fica. Verificou-se que 70,7% e 94,5% das medidas foram do tipo precisas ou aceit?veis, respectivamente. A acur?cia das medidas correlacionou-se positivamente com as limas explorat?rias e negativamente com o di?metro do CR. Nenhuma vari?vel independente influenciou a acur?cia do LAE (p>0.05). Conclus?o: O Apex Finder proveu medidas de CT com elevada aceitabilidade cl?nica na regi?o da constri??o apical, independentemente do estado pulpar, grupo dentes, estado periapical ou di?metro dos canais radiculares. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2014. / ABSTRACT of root canals (RC). Objective: To evaluate clinically associated factors with the accuracy of the electronic apex locator (EAL) Apex Finder A.F.A. 7005 in determination of apical constriction. Methodology: For each RC, one selected file type Kerr and coupled at EAL was inserted intracanal until stablished marking, 1 mm on the liquid-crystal display (LCD). The periapical radiograph correspondent the distance of the file tip to the tooth apex was classified as specify (0.5 to 1.5 mm), acceptable (0 to 2 mm) or imprecise (other steps). The agreement was analyzed according to the group of teeth, pulpal and periapical status, RC diameter and exploratory file diameter. The influence of independent variables was analyzed by Mann-Whitney, Kruskal-Wallis and Spearman correlation (p <0.05) tests. Results: The anterior teeth (n=21), premolars (n=20) and molars (n=33) provided RC 147, of which 43.5% were atresic. In 102 (69.4%) the pulp was necrotic, among which 70 (47.6%) had periapical radiolucency. High agreement between the electronic and radiographic measurement was obtained. It was found that 70.7% and 94.5% of the measurements are accurate and acceptable type, respectively. The accuracy of measurements correlated positively with exploratory files and negatively with the diameter of RC. No independent variable influenced the accuracy of LAE (p> 0.05). Conclusion: The Apex Finder provided measures of WL with high clinical acceptability in apical constriction, regardless of status pulp, tooth group, periapical status or diameter of the root canals.
16

Avaliação in vivo da precisão do Root ZX II em localizar o forame em dentes com periodontite apical / Lucia Piasecki ; orientador, Ulisses Xavier da Silva Neto

Piasecki, Lucila January 2011 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2011 / Bibliografia: f.36-43 / Avaliou-se in vivo a precisão do aparelho Root ZX II em localizar o forame apical em dentes com periodontite apical. Vinte e sete dentes unirradiculados com exodontia indicada foram selecionados. O Grupo 1 foi composto por doze dentes com necrose pulpar / This study was conducted in vivo to investigate the accuracy of Root ZX II in locating the apical foramen in teeth with apical periodontitis. Twenty seven single root teeth scheduled for extractions were selected: in Group 1 twelve teeth with pulp necrosi
17

Avaliação da precisão do controle de extensão apical da instrumentação rotatória utilizando o root ZX II e instrumentos protaper : estudo in vivo / Sandra Joia Mizrahi Jakobson ; orientador Everdan Carneiro

Jakobson, Sandra Joia Mizrahi January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografias / Avaliou-se in vivo a precisão do aparelho Root ZX II (J. Morita, Kyoto, Japão) em controlar a extensão apical da instrumentação rotatória. Vinte e quatro pré-molares unirradiculares foram selecionados. As raízes foram divididas em dois grupos de acordo co / The accuracy of Root ZX II (J. Morita, Kyoto, Japan) to control the apical extent of rotary canal instrumentation in vivo was assessed. Twenty-four premolars with single canal were selected. The roots were divided in two groups according to the calibratio
18

Influência do diâmetro do forame apical e do calibre do instrumento endodôntico nas leituras odontométricas proporcionadas por dois aparelhos localizadores apicais / Influence of foramen diameter and endodontic instrument size on odontometry reading by two electronic apex locators

Járcio Victório Baldi 17 June 2005 (has links)
Este estudo objetivou avaliar a influência do diâmetro do forame e do instrumento endodôntico na leitura odontométrica de dois aparelhos localizadores apicais eletrônicos. Foram utilizados 40 dentes incisivos inferiores, divididos em 4 grupos, de acordo com o diâmetro do forame apical (100, 200, 300 e 400 µm). Após a abertura coronária desses dentes e o acesso aos canais radiculares, realizou-se a medição do comprimento dos mesmos com auxílio de um microscópio clínico com ampliação de 7,8X, da incisal até que a ponta da lima surgisse no forame apical. Os dentes foram colocados em potes individuais contendo solução de ágar a 1% em solução salina de fosfato tamponado, mantendo-se cerca de 2/3 de suas raízes imersas na solução para que pudesse ser feita a leitura com o Root ZX® (J.Morita, Japão) e o NovApex® (Fórum, Israel). Os mesmos foram medidos com limas nº10 até que a distância de 0,5 mm do ápice fosse acusada no display dos aparelhos. Uma outra medida foi realizada nos dentes utilizando-se lima nº10 e limas com diâmetros correspondentes ao diâmetro dos forames (200µm, 300µm e 400µm). Para a análise estatística foi empregado o teste de Análise de Variância a dois critérios para o confronto global entre os aparelhos e o emprego da lima nº10 em todos os dentes e teste de Tukey para as comparações individuais. Os resultados demonstraram diferença estatística na precisão dos dois aparelhos com um resultado mais preciso para o Root ZX® (p<0,05). Dentes com forame, de menor diâmetro, apresentaram uma medida mais precisa com o localizador apical e dentes com forame de maior diâmetro apresentaram uma maior discrepância na medida. O emprego de limas tipo K nº10 nos dentes com forames de diâmetros maiores apresentaram maior precisão na medição quando comparadas às limas coincidentes aos diâmetros dos forames para o aparelho Root ZX®. Para o NovApex® esta correlação só passou a ocorrer a partir da lima nº40. / This study evaluated the influence of foramen diameter and endodontic instrument size on the odontometry reading of two electronic apical measuring devices. Forty mandibular incisors were used, which were divided into four groups according to the apical foramen diameter (100, 200, 300 and 400µm). After coronal opening of these teeth and access to the root canals, the root canal length was measured with aid of a clinical microscope with 7.8x magnification, from the incisal edge until the file tip reached the apical foramen. Ten teeth with 100-µm diameter were placed in individual jars containing 1% agar solution in phosphate-buffered saline, maintaining around 2/3 of their roots immersed in the solution to allow measurement with Root ZX (J. Morita, Japan) and NovApex (Forum, Israel). Teeth were measured with files n. 10 until the distance of 0.5mm from the apex was indicated by the device. Another measurement was performed on the other thirty teeth with files n. 10 and files with diameters corresponding to the foramen diameters (200µm, 300µm and 400µm). Statistical analysis was performed by two-way analysis of variance for overall comparison between the devices and employment of file n. 10 in all teeth, and Tukey test for individual comparisons. The results demonstrated statistical difference in the precision of both devices, with a more accurate result for Root ZX (p<0.05). Teeth with narrower foramina presented a more accurate measurement with the apical measuring device, and teeth with wider foramina presented larger discrepancy in the measurement. Utilization of K file n. 10 in teeth with wider foramina showed more accurate measurements compared to files with size corresponding to the foramen diameters with the Root ZX® device. With the NovApex® device, this correlation was only observed with file n. 40.
19

"Validação das ferramentas de calibragem de medidas em três sistemas de radiografia digital" / Assessment of calibration tools of three digital radiography systems

José Raul Girondi 30 March 2006 (has links)
O desenvolvimento tecnológico busca fatores que possibilitem uma menor exposição do paciente e profissional aos raios ionizantes, maior agilidade no atendimento ao paciente e maior auxilio no desenvolvimento do diagnóstico final. Assim a associação entre informática e radiologia básica, traduzidas como radiologia digital, fez-se conseguir os fatores buscados. Uma ferramenta dos sistema digitais é a calibração prévia às medidas. Com essas observações avaliamos tais ferramentas de três sistemas de radiografias digitais, objetivando validar e comprovar sua eficácia nas metodologias dos trabalhos presentes e futuros. Para tanto utilizamos 20 dentes humanos secos provindos do Banco de Dentes Permanentes da FOUSP, os quais foram radiografados com o auxílio de três sistemas de radiografia digital, direto e semidireto (Digora, RVG Trophy e Visualix). O padrão ouro das medidas dos dentes foi a verificação das dimensões dos dentes por meio de um paquímetro digital e posteriormente comparados os seus padrões de medidas com os softwares dos respectivos sistema. Os resultados foram analisados estatisticamente pelo ANOVA (métodos de Tukey e Dunnett), chegando às seguintes conclusões: existe diferença significante entre os aparelhos p<0,001; a média das medidas obtidas houve diferença significante (p<0,001) com o aparelho Digora foi menor que as médias obtidas com os aparelhos das marcas Visualix e RVG; considerando-se o padrão A e o padrão B de calibragem, não existe diferença estatística significante entre os avaliadores; considerando-se a calibragem sem padrão, um dos avaliadores obteve média mais elevada que os demais avaliadores no caso das medidas realizadas com o aparelho Digora, porém este fato não se repetiu quando da utilização dos outros aparelhos; comparando-se as medidas de referência (paquímetro) observa-se que mais uma vez o aparelho Digora (padrão A, padrão B e sem padrão) apresentou diferença significativa; os aparelhos das marcas Visualix e RVG não mostraram diferenças significativas quando comparados com o valor de referência. / Technological development aims at reducing exposure of both the professional and the patient to ionizing radiation, improving patient treatment and aiding final diagnosis. The combination of computer technology and radiology, i.e. digital radiography, has made this possible. One of the tools of digital radiography systems is calibration prior to measurement. The purpose of this study was to assess the calibration tools of three digital radiography systems to verify their efficacy. Twenty human teeth obtained from the Human Teeth Bank of the School of Dentistry, University of São Paulo, were used. The dry teeth were radiographed using three different direct digital radiography systems Digora, RVG Trophy and Visualix. The measurements of the teeth obtained with a digital caliper were considered the gold standard. These measurements were later compared with those obtained using the digital systems. The results were submitted to ANOVA (methods of Tukey and Dunnett), and the following conclusions were drawn: there was a significant difference between the systems used (p < 0.001); the averages of the measurements obtained with the three systems were significantly different (p<0,001). Visualix and RVG were more accurate than Digora considering A and B calibration standards, no significant difference was observed between the examiners; when there was no calibration standard and the Digora system was used, one examiner obtained more high averages measurements than the others; when there was no calibration standard and Visualix or RVG systems were used, no differences were observed between the examiners; the measurements obtained with Digora system (standards A, B or no standard) were statistically different from the gold standard the measurements obtained with Visualix and RVG systems presented no significant difference when compared with the gold standard.
20

Afinidades biológicas extra-continentais dos paleoíndios tardios de Lagoa Santa e suas implicações para a questão do povoamento do novo mundo: uma abordagem odontométrica / Extra-continental biological afinities among Late Paleoindian of Lagoa Santa, Central Brazil, and its implications for the settlement of America: an odontometric view

Tatiana Leite Nunes 17 March 2010 (has links)
Atualmente, quatro principais modelos discutem o Povoamento da América. O mais antigo defende a entrada de três levas migratórias (Greenberg et al., 1986), outro modelo, duas (Neves et al., 1989), o modelo genético, apenas uma (Bonatto & Salzano, 1997) e, recentemente, Gonzalez-José et al. (2008) apresentaram um modelo de fluxo continuo. O presente trabalho investigou as afinidades biológicas de uma população paleoíndia brasileira, a de Lagoa Santa, com antiguidade estimada entre 11.500-7.500 A.P., comparando-a a outras populações mundiais (Banco de Dados Hanihara). A investigação baseou-se em análise odontométrica (diâmetros dentários mesiodistais e bucolinguais). Os dentes apresentam alta herdabilidade, morfogênese estável, grande representatividade arqueológica e são pouco influenciados por fatores ambientais imediatos. As afinidades biológicas dos paleoíndios de Lagoa Santa foram exploradas por Análise Multivariada, com a aplicação de Análise de Componentes Principais e Matrizes de Dissimilaridade (Euclidianas e Mahalanobis), estas últimas visualizadas por Análises de Cluster e de Escalonamento Multidimensional. Diferentes sets de análises foram realizados, para ambos os sexos considerando-se tamanho e forma e somente forma. Os resultados apresentados demonstram uma forte tendência de diferenciação da população de Lagoa Santa em relação às populações nativas americanas tardias e atuais, associando-se mais fortemente com Polinésios e Sudeste Asiáticos. Estes resultados questionam a homogeneidade dos nativos americanos e apóiam fortemente o modelo dos Dois Componentes Biológicos Principais (Neves et al., 1989). / Nowadays, four principal models discuss the settlement of the Americas. The oldest one defends three waves into the continent (Greenberg et al, 1986), other model, two (Neves et al., 1989), the gentic one, only one (Bonatto & Salzano, 1997), and recently, Gonzalez et al. (2008) presented a continuous flow model. The present study investigated the biological affinities of a Paleoindian Brazilian population, Lagoa Santa, with estimated antiquity between 11500-7500AP, comparing them to others word populations (Hanihara Data Bank). The investigation was based on odontometry data (mesiodistal and bucolingual diameters). Teeth have high heritability, stable morphogenesis, high archaeological presence, and are little influenced by immediate environmental factors. The biological affinities of Lagoa Santa Paleoindians were explored by Multivariate Analyses, with the application of Principal Components Analysis and Matrix Dissimilarities (Euclidian and Mahalanobis), the later visualized by Cluster Analysis and Multidimensional Scaling. Different sets of analysis were carried out for both sexes considering size and shape and shape alone. The results point to a strong tendency of differentiation of the Lagoa Santa population in relation to other Native Americans, and a strong association with Southeast Asians and Polynesians. The results strongly support the Two Main Biological Components Model (Neves et al., 1989).

Page generated in 0.0498 seconds