• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 63
  • 50
  • 10
  • 5
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 164
  • 92
  • 91
  • 35
  • 34
  • 33
  • 33
  • 30
  • 25
  • 23
  • 21
  • 21
  • 18
  • 17
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Exploration and application of post-infrared high-temperature infrared stimulated luminescence dating techniques: investigation of marine terrace deposits along the northern San Andreas Fault

Roozeboom, Jennifer Elizabeth January 1900 (has links)
Master of Science / Geology / Joel Q. Spencer / Optically stimulated luminescence (OSL) dating is a relatively new dating method, tangibly introduced in 1985 when Huntley et al. demonstrated the ability to use light-sensitive traps to measure radiation exposure and determine the age of sediment. Quartz and feldspar grains are commonly used for the method, with quartz receiving significantly more attention than feldspars until the past decade. Recent research has improved the practicality of using feldspars as a reliable dosimeter –an appealing notion as the intrinsic properties of feldspars allow them to date older sediment that may lie beyond the reliable range of quartz dosimetry. This work explores and utilizes the contemporary feldspar technique termed post-infrared, high-temperature infrared stimulated luminescence (pIRIR) dating to add to the existing knowledge base of this method, particularly by testing different preheat and measurement temperature combinations. Analysis of the each pIRIR method indicates that the pIRIR signal stimulated at 225°C is more appropriate for dating than the pIRIR signal stimulated at 290°C. Techniques and protocols developed in this work are done so via their application to a marine terrace that is displaced by the San Andreas Fault. Corals from the terrace along the Pacific plate, dated with U-series by Muhs et al. (2002), offer an age estimate. Comparison of the pIRIR ages to the U-series ages yield an underestimation, suggesting the pIRIR method may be more useful as a means of correlating terraces across the fault, than for providing ages of terrace formation.
102

Autodiagnostic des perturbations des réseaux d’antennes : application à la goniométrie. / Auto diagnostic of Radiation Perturbation of Antenna Array for Direction : Finding Application

Ghattas, Lama 14 January 2015 (has links)
Cette thèse porte sur la conception d’un système de mesure in-situ permettant de détecter les perturbations variables dans l’environnement proche d’un réseau d’antennes. Une première partie est consacrée à l’étude du bénéfice d’un tel système appliqué à un réseau de goniométrie. Une étude quantitative de la dégradation des performances de goniométrie sur porteur en présence d’obstacles variables est réalisée. Le deuxième point majeur de cette thèse est le choix de la technologie pour la conception du système de diagnostic. La Technique de diffusion modulée par l’optique (OMS) est sélectionnée. Un modèle de prédiction de la puissance rétrodiffusée par la sonde OMS a été élaboré afin de choisir la dimension de sonde optimale. Suite aux études théoriques, une sonde de 12 cm chargée par la photodiode (PDCS30T) a été réalisée. Des mesures en chambre anéchoïque ont été menées afin de valider le bilan de liaison et mesurer la sensibilité de la sonde à des obstacles proches. Finalement, une étude est réalisée afin d’étudier la sensibilité exigée par le réseau de diagnostic pour détecter la présence d’obstacles. Un dimensionnement du système global est calculé. / This thesis focuses on the design of an in-situ measurement system to detect variable disturbances in the near field of antenna arrays. The first part was focused on the study of the benefit of the monitoring system for direction finding antennas (DFA). A quantitative study of degradation of performances of DFA installed on a carrier in presence of variable obstacles was done. The second point of the study concerns the choice for the technology for the diagnostic system design. The Optically Modulated Scatterer Technique (OMS) is selected. A model that predicts the OMS backscattered power is developed to select the optimal dimension of the probe. Following the theoretical studies, a 12 cm OMS probe coupled to the nonlinear device (PDCS30T) was designed. Measurements in anechoic chamber were conducted to validate the budget link model and measure the sensitivity of the probe to nearby objects. Finally, a study is conducted to investigate the sensitivity required by the diagnostic probes for detecting the presence of obstacles. A dimensioning of the overall system is computed.
103

Contribuição da dinâmica morfoestrutural e morfoescultural na estruturação da bacia do Ribeirão Entupido, complexo alcalino do Passa Quatro - SP /

Arruda, Emerson Martins. January 2008 (has links)
Resumo: A pesquisa analisa os eventos deposicionais, esculturadores do relevo, na bacia do Ribeirão Entupido, Complexo Alcalino do Passa Quatro, Estado de São Paulo, a partir do estudo dos depósitos recentes da área. Além da análise geomorfológica na referida unidade espacial, a pesquisa buscou estabelecer a idade absoluta de deposição de algumas unidades sedimentares estruturadoras do relevo e os mecanismos envolvidos na sua gênese. Neste contexto, utilizou-se datações por Luminescência Opticamente Estimulada (LOE) e Termoluminescência (TL). Os depósitos sedimentares foram estudados a partir da abordagem morfoestratigráfica. O cruzamento de dados morfoesculturais e morfoestruturais e de datação absoluta permitiu estabelecer quais mecanismos, atuantes ao longo do último milhão de anos, comandaram a morfogênese na bacia em foco. A determinação da morfogênese permitiu definir a susceptibilidade do relevo às mudanças ambientais, inclusive às intervenções antrópicas. Os depósitos sedimentares apresentaram idades vinculadas ao Pleistoceno Superior (61.500 anos) e Holoceno (650 anos) representando, portanto, eventos diferenciados no desenvolvimento e localização deste ambientes. A complexidade da paisagem na bacia do Ribeirão Entupido envolve justamente esta interdigitação de materiais de idades diversas que compõem o mesmo ambiente de deposição, interferindo conjuntamente a tectônica e as condições climáticas, a priori, na espacialização dos depósitos e nas características dos sedimentos. / Abstract: This research of doctor's grade analyze the depositional and sculptural events, at stream Entupido basin, Passa Quatro Alkalin Complex, Estate of São Paulo, from the study of recent deposits.Beyond the geomorphologycal analysis at referred spacial unit, this research tried to establish the absolute age of some sedimentary units that structure the relief and the mechanism involved in its genesis. The dating method of Optically Stimulated Luminescence (OSL) Thermoluminescence (TL) was used in that context.The sedimentary deposits were studied by morphostratigraphic approach. The crossing of mophosculptural and moprostructural data and absoluting dating allow establish wich mechanism, acting through the last million years, commanded the morphogenesis process at the basin.The determination of morfogenesis allowed define the susceptilidy of relief to ambiental changes, including antropic intervention. The sedimentary deposits show ages linked at Up Pleistocene (61.500 years) and Holocene (650 years), showing, therefore, differenced events in development and localization of this environment.The landscape complexity in stream Entupido basin, involves precisely this interdigitation of materials and different ages that compose the same depositional environment, interfering jointly tectonic and climatic conditions, in prior, at specialization of deposits and sedimentary characteristics. / Orientador: Iandara Alves Mendes / Coorientador: Francisco Sérgio Bernardes Ladeira / Banca: Archimedes Perez Filho / Banca: Salvador Carpi Júnior / Banca: Cenira Maria Lupinacci da Cunha / Banca: Regina Célia de Oliveira / Possui 5 mapas anexos / Doutor
104

Cronologia e sedimentologia dos depósitos eólicos quaternários da Costa Leste maranhense

Guedes, Carlos Conforti Ferreira 30 October 2012 (has links)
Idades por luminescência opticamente estimulada foram obtidas nos depósitos eólicos do litoral leste maranhense. As datações permitiram reconhecer ao menos quatro gerações de dunas eólicas, incluindo a atual. As duas gerações mais antigas (G1/G0: idades LOE de 258,9±24,6 a 88,0±8,6 ka A.P.) não são distinguíveis por critérios de campo, somente por dados geocronológicos. A geração eólica 2 corresponde a feições eólicas estabilizadas pela vegetação que ocorrem a até 135 km da linha de costa atual. As idades LOE-SAR de estabilização obtidas para essas feições eólicas compreendem um intervalo estreito de tempo (19 a 14 ka A.P.) no Pleistoceno superior. Essa fase estabilização do sistema eólico é correlacionada com o evento climático HS-1. Durante esse período no leste maranhense, sob maior influência da Zona de Convergência Intertropical pelo seu deslocamento para sul, ocorreu diminuição da intensidade dos ventos alísios e aumento da precipitação. Essas variações climáticas diminuíram a capacidade de transporte eólico e levou o sistema à estabilização. A análise de proveniência sedimentar com base em minerais pesado identificou como principal fonte sedimentar do litoral leste maranhense a plataforma continental localizada a leste da foz do rio Parnaíba, alimentada via deriva litorânea longitudinal para oeste. O rio Parnaíba aparentemente tem contribuição minoritária como fonte sedimentar, tanto para o sistema atual como para as gerações eólicas pretéritas. A dinâmica sedimentar do sistema eólico atual, evidenciada por minerais pesados, granulometria e parâmetros morfoplanimétricos, aponta para intenso retrabalhamento por rios que o limitam parcialmente ao interior e por drenagens intermitentes, de caráter entrelaçado, que o atravessam. O estudo do método de datação LOE e as características LOE dos sedimentos de diferentes localidades do Brasil permitiu identificar a boa aplicabilidade do método vista a alta sensibilidade LOE do quartzo e bom desempenho nos testes aplicados. A sensibilidade LOE do quartzo foi identificada como a principal característica determinante da qualidade da datação LOE. A proposição da razão de sensibilidade Quartzo-\"Al IND.2\'\'O IND.3\':C (\'delta\'\'POTs\' Q) permitiu tanto a padronização do cálculo da sensibilidade LOE como a comparação de medidas interlaboratoriais. A observação de grandes variações nos valores de sensibilidade LOE de quartzo para sedimentos de diferentes localidades são resultado tanto das rochas fonte como dos ciclos de sedimentação e retrabalhamento. A identificação de diferentes proveniências sedimentares com base no uso da sensibilidade LOE foi aplicada, com sucesso, na análise de variações climáticas baseada em mudanças de proveniência sedimentar na Ilha Comprida -SP. / Optically stimulated luminescence (OSL) ages were obtained in eolian deposits from the east coast of Maranhão, Brazil. OSL dating allowed the identification of at least four generations of eolian dunes, including the active dunefields. The two oldest generations (G1/G0: OSL ages 258.9±24.6 to 88.0±8.6 ky B.P.) are not distinguishable by field criteria, only geochronological data. Generation 2 corresponds to eolian features stabilized by vegetation that occurs up to 135 km from the current coast line. OSL-SAR ages of stabilization of these features are between 19 and 14 ky B.P., a narrow time interval during Pleistocene. This event is related to the climatic event HS-1. During this period the intensity of trade winds decreased and precipitation increased in the area due to a greater influence of the Intertropical Covergence Zone, which was shifting south. These climatic variations reduced the capacity of eolian transportation and the led system to to stabilization. Provenance analyzes by heavy minerals identified the continental shelf located east of the Parnaiba river mouth as sedimentary source for the east coast of Maranhão, which is fed by longitudinal litoral drift to west. Parnaiba river apparently has a minor contribution as sedimentary source for recent and past eolian generations. Sedimentary dynamic of the recent eolian system, as indicated by heavy minerals analyzes, grain size analyzes and morphoplanimetric parameters, is characterized by strong reworking by rivers, braided intermittent drainages, that cross the dunefield. All analyzed Brazilian sediments presented relatively high OSL sensitivity and good behavior regarding their luminescence characteristics relevant for radiation dose estimation. The OSL sensitivity of quartz was identified as the main characteristic interfering the OSL dating quality. We propose to standardize the definition of quartz OSL sensitivity using the Quartz-to-\'Al IND.2\'\'O IND.3\':C sensitivity ratio (\'delta\'\'POT.s\'Q). The standardization is a prerequisite to compare data obtained under different measurement conditions and to investigate and develop geological applications of quartz OSL sensitivity. We observed that the major factor controlling the OSL sensitivity is the sedimentary history of the sediment. Longer sedimentary transport provided by huge drainage systems and long-distance littoral drift increases the OSL sensitivity. The use of OSL sensitivity as provenance proxy was successfully applied at Ilha Comprida-SP to analyze climate variations.
105

Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico - VMAT / Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT

Bravim, Amanda 11 June 2015 (has links)
A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento. / The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and theLiF:Mg,Ti (TLD-100), CaSO4:Dy and Al2O3:C dosimeters and LiF:Mg,Ti microdosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30x30x30 cm3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti microdosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital.
106

Production of a Bose-Einstein condensate of sodium atoms and investigation considering non-linear atom-photon interactions / Producção de um Condensado de Bose-Einstein de átomos de sódio e investigação considerando interações não lineares entre átomos e fótons

Peñafiel, Edwin Eduardo Pedrozo 22 August 2016 (has links)
In this work we constructed an experimental system to realize a BEC of sodium atoms. In the first part of the work, we study two atomic sources in order to choose the most suitable for our system. The comparison between a Zeeman slower and a bidimensional magnetooptical trap (2D-MOT) was performed to evaluate the capacity of producing an appropiate flux of atoms in order to load a tridimensional magneto-optical trap (3D-MOT). The experimental results show that the 2D-MOT is as efficient as the Zeeman slower with the advantage of being more compact and easier to operate, and for these reasons we choose it as our source of cold atoms. After this, the experimental apparatus to produce a Bose-Einstein condensate was constructed and characterized. With this experimental system we realized all the required stages to achieve the Bose-Einstein condensation (BEC). Initially, we characterized and compared the performance between the Bright-MOT and Dark-SPOT MOT of sodium atoms, observing the great advantages this last configuration offers. Afterward, we implemented the experimental sequence for the achivement of the BEC of sodium atoms. After the optical molasses process, the atoms are tranferred to an optically plugged quadrupole trap (OPT) where the process of evaporative cooling is performed. With this setup, we achive a sodium BEC with ∼ 5×105 atoms and a critical temperature of ∼ 1.1 μK. Finally, with the constructed and characterized machine, we started to perform experiments of cooperative absorption of two photons by two trapped atoms. With the new system, we wanted to take advantage of the higher densities in the magnetic trap and BEC to explore some features of this phenomenon in the classical and quantum regimes. We were interested in exploring some features of this nonlinear light-matter interaction effect. The idea of having two or more photons interacting with two or more atoms is the beginning of a new possible class of phenomena that we could call many photons-many body intercation. In this new possibity, photons and atoms will be fully correlated, introducing new aspects of interactions. / Neste trabalho, realizamos a construção de um sistema experimental para a realização de um condensado de Bose-Einstein de átomos de sódio. Na primeira parte do trabalho, realizamos o estudo de duas fontes átomicas com o intuito de escolher a mais adequada para nosso sistema experimental. A comparação foi realizada entre um Zeeman slower e uma armadilha magneto-óptica bidimensional (MOT-2D), que são técnicas usadas para fornecer um grande fluxo de átomos com distribuição de velocidades adequadas para serem capturados numa armadilha magneto-óptica tridimensional (MOT-3D). Os resultados experimentais da caracterização de ambos os sistemas mostra que o MOT-2D oferece um grande fluxo atômico da mesma ordem do Zeeman slower, mas com a vantagem de ser um sistema mais compacto em questão de tamanho, razão pela qual foi escolhido como fonte atômica no nosso sistema. A partir daqui, realizamos a construção do sistema experimental para a realização do condensado de sódio. Inicialmente realizamos o aprisionamento numa MOT-3D, realizando subsequentemente os passos de resfriamento sub-Doppler mediante o processo de molasses ópticas. Depois disto, os átomos são transferidos para uma armadilha magnética, que consiste de um par de bobinas em configuração anti-Helmholtz, as mesmas usadas para a MOT-3D mas com um gradiente de campo magnético ao redor de uma ordem de grandeza maior. Esta armadilha é combinada com um laser com dessintonia para o azul focado a 30 μm no centro da armadilha, onde o campo magnético é zero com o objetivo de evitar as perdas por majorana que acontecem nessa região. Com esta configuração, um condensado de ∼ 5 × 105 átomos é obtido a uma temperatura crítica de ∼ 1.1 μK. Por último, com a máquina construída e caracterizada, começamos re-explorar o experimento de absorção cooperativa de dois fótons por dois átomos aprisionados. Com nosso novo sistema, é possível explorar este efeito no regime clássico e quântico. Estamos interessados em explorar algumas características da interação não linear entre luz e matéria. A ideia de ter dois ou mais fótons interagindo com um ou mais átomos, é possivelmente o começo de uma nova classe de fenômenos que poderíamos chamar de interação de muitos fótons com muitos átomos.
107

Estudo das propriedades de armazenamento óptico e grades de relevo em poliuretano derivado de azo-benzeno / Information optically storage and relief gratings study in material derivative of azo-benzene polyrethane

Neves, Ubaldo Martins das 30 June 2003 (has links)
Polímeros contendo grupos azo-benzênicos têm sido estudados devido a sua capacidade para óptica não linear, formação de superfícies de relevo e de birrefringência fotoinduzida. O fator que possibilita essas aplicações é a propriedade de fotoisomerização reversível trans-cis-trans do grupo azo que produz a sua reorientação molecular. Neste trabalho foram produzidos filmes casting do poliuretano MDI-DR19 derivado de azo-benzeno. Estudou-se o crescimento e decaimento da birrefringência para diferentes valores de potência da luz de excitação da fotoisomerização. Os resultados experimentais do crescimento e decaimento foram analisados usando duas exponenciais e eles mostraram que o polímero MDI-DR19 apresenta boas características para utilização em armazenamento óptico pois cerca de 65% da birrefringência induzida no material permanece por longos intervalos de tempo. Ilustramos o processo de armazenamento de informação gravando uma imagem de birrefringência num filme de MDI-DR19. Foram também produzidas grades de relevo em filmes de MDI-DR19 utilizando franjas de interferência produzidas com luz de polarização P e S. Essas grades apresentaram alta uniformidade e características compatíveis com as mostradas na literatura. / Polymers containing azobenzenic groups have been studied due to their applications on non-linear optics, surface relief gratings (SRG) and photoinduced anisotropy for optical storage. The reversal photoisomerization trans-cis-trans property of the azo group induces a molecular reorientation. In this work, cast films of na azobenzene derivative, the polyurethane MDI-DR19, were studied. The build-up and decay of the birefringence were studied as a function of the photoisomerization exciting light power. The data of the build-up and decay of the birefringence were fitted with a bi-exponential function, which shows the stability of the MDI-DR19 for application in optical storage, since 65% of the induced birefringence remains after a long time. The optical storage is illustrated by recording a birefringence image in a film of MDI-DR19. It was also performed a SRG over films of MDI-DR19 applying an interference finger pattern with a P and S polarized light. The light induced gratings shows good uniformity and characteristics compatible with those presented in the literature.
108

Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico - VMAT / Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT

Amanda Bravim 11 June 2015 (has links)
A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento. / The Volumetric Modulated Arc Therapy (VMAT) is an advance technique of Intensity Modulated Radiation Therapy (IMRT). This progress is due to the continuous gantry rotation with the radiation beam modulation providing lower time of the patient treatment. This research aimed the verification of the isodose curves in a simulation of a vertebra treatment with spinal cord protection using the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques and theLiF:Mg,Ti (TLD-100), CaSO4:Dy and Al2O3:C dosimeters and LiF:Mg,Ti microdosimeters (TLD-100). The dosimeters were characterized using PMMA plates of 30x30x30 cm3 and different thickness. All irradiations were done using Truebeam STx linear accelerator of Hospital Israelita Albert Einstein, with 6 MV photons beam. After the dosimeter characterization, they were irradiated according the specific planning simulation and using a PMMA phantom developed to VMAT measurements. This irradiation aimed to verify the isodose curves of the treatment simulation using the two dosimetry techniques. All types of dosimeters showed satisfactory results to determine the dose distribution but analysing the complexity of the isodose curves and the proximity of them, the LiF:Mg,Ti microdosimeter showed the most appropriate for use due to its small dimensions. Regarding the best technique, as both technique showed satisfactory results, the TL technique presents less complex to be used because the most of the radiotherapy departments already have a TL laboratory. The OSL technique requires more care and greater investment in the hospital.
109

Estudo do comportamento de sinais OSL de BeO e Al2O3:C usando o Modelo OTOR Simplificado e Método dos Mínimos Quadrados / Study of the Behavior of OSL Signals of BeO and Al2O3:C using the Simplified OTOR Model and Least Square Method

Soares, Leonardo dos Reis Leano 02 October 2018 (has links)
A dosimetria das radiações alfa, beta e gama é importante para diversas áreas aplicadas, sendo utilizada na proteção radiológica de pacientes e profissionais que se expõem a esses tipos de radiações. Com estudos dosimétricos pode-se obter melhores estimativas de dose absorvida, e ter mais precisão na estimativa de riscos populacionais. As técnicas de Termoluminescência (TL) e Luminescência Oticamente Estimulada (OSL) são utilizadas para essas aplicações dosimétricas. Estudos recentes têm mostrado que alguns materiais dosimétricos conhecidos como óxido de alumínio dopado com carbono (Al$_2$O$_3$:C) e óxido de berílio (BeO) sofrem mudanças no formato observado dos sinais OSL com relação as taxas de dose e tipos de radiação. O principal objetivo desse trabalho foi analisar os formatos dessas curvas e verificar quantitativamente, se existem ou não mudanças nos formatos dos sinais OSL dos dosímetros irradiados com diferentes tipos de radiação e taxas de dose. Sob o modelo de uma armadilha e um centro de recombinação (OTOR) foram estudados os sinais OSL com estímulo contínuo (CW-OSL). O modelo OTOR é simples, mas não possui solução analítica e as soluções computacionais são custosas pelo número grande de variáveis e parâmetros. Nesse trabalho, foi necessário realizar algumas simplificações para obtenção de um modelo ainda mais simples para ajuste nos dados. O modelo OTOR simples apresenta um comportamento de decaimento exponencial na descrição do sinal CW-OSL. Uma outra abordagem de extensão do modelo OTOR-simples foi a utilização do modelo com duas armadilhas independentes e um centro de recombinação, que resulta em dois decaimentos exponenciais. Para obtenção dos parâmetros que descrevem o sinal CW-OSL com esses modelos, foi utilizado o método dos mínimos quadrados (MMQ), com refinamento dos parâmetros pelo método de Gauss. O modelo de dois decaimentos exponenciais mostrou-se superior em qualidade com análise do parâmetro $\\chi^2$ e do comportamento dos resíduos em relação ao modelo de um decaimento exponencial para ambos os materiais utilizados. Com os ajustes, foi possível verificar diferenças nos comportamentos do sinal CW-OSL das amostras irradiadas em diferentes situações. As diferenças observadas nos comportamentos são apresentadas pelos parâmetros de decaimento ou de sinal inicial, ou pelas relações entre esses. Os parâmetros ajustados mostram que os sinais OSL provenientes do Al$_2$O$_3$:C e do BeO irradiados com alfa, beta e gama apresentam diferenças significativas nos comportamentos. As diferenças verificadas pelos ajustes dos sinais CW-OSL apresentados pelos dosímetros irradiados com beta e gama podem ter sido em parte causadas por efeito de fading, que afeta de maneira distinta os formatos das curvas e parâmetros ajustados. Nas irradiações com radiação gama com faixas de doses (de 22 a 122 mGy) e taxas doses absorvidas (de 0.024 a 1.66 Gy/s) não foram observados diferenças significativas nos sinais OSL. / The dosimetry of alpha, beta and gamma radiation is important in various applied areas, it is used in radiation protection of patients and professionals who are exposed at this kind of radiation. With dosimetric studies, it is possible to better estimate the absorbed dose, and population risks. Thermoluminescence (TL) and Optically Stimulated Luminescence (OSL) techniques are used for these dosimetric applications. Recent studies have shown that some known dosimetric materials as carbon doped aluminum oxide (Al$_2$O$_3$:C) and berilium oxide (BeO) undergo changes in OSL signal behavior related to dose rates and types of radiation. The main objective of this work was to analise the formats of these curves and quantitatively verify whether or not there are changes in OSL signal of the dosimeters irradiated with different types of radiation and dose rates. Under the model of one trap one recombination center (OTOR) the continuous wave OSL (CW-OSL) signals were studied. The OTOR model is the simplest model, but has no analytical solution and the computational solutions are costly by the large number of variables and parameters. In this work, it was necessary to make some simplifications in order to obtain a simple model that could be fitted to the data. The simple-OTOR model shows an exponential decay behavior in the CW-OSL signal description. Another extension approach to the simple-OTOR model was the model with two independent traps and one recombination center, that results in two exponential decays. To obtain the parameters that describe the CW-OSL signal with these models, the least square method (LSM) was used, with parameter refinement by Gauss method. For both the materials the two exponential decay model proved to be superior in quality to the one exponential decay by the analysis of the parameter $\\chi^2$ and the behavior of the residuals. With the fittings, it was possible to verify differences in the behavior of the CW-OSL signal of the samples irradiated in different situations. These differences observed are presented in the decay or initial signal parameters, or in their ratios. Fitted parameters show that OSL signals from Al$_2$O$_3$:C and BeO irradiated with alpha, beta and gamma exhibit significant differences in behavior. The differences verified by the fittings of the CW-OSL signals presented by beta and gamma irradiated dosimeters may in part have been caused by fading effect, which affects in a different way the shapes of the curves and fitted parameters. Gamma irradiation with dose and absorbed dose rate ranges from 22 to 122 mGy and from 0.024 to 1.66Gy/s respectively did not produce significant differences in OSL signals.
110

New insights into old problems : the application of a multidisciplinary approach to the study of early Egyptian ceramic chronology, with a focus on luminescence dating

Hood, Amber Giles Eve January 2016 (has links)
This thesis takes a multidisciplinary approach to the study of ancient Egyptian ceramics by applying scientific dating techniques alongside more traditional methods. It is the first study to apply OSL dating to an Egyptian ceramic assemblage, and it has done so by developing the minimum extraction technique (MET), which has made it possible to use OSL to sample, and thus analyse, ceramics housed in museums. The MET is at present essential to the success of OSL dating of Egyptian ceramics, as the exportation ban on antiquities has prevented OSL analysis of field material. For this thesis, using this new sampling technique, OSL has been applied to several assemblages from the Predynastic to the Early Dynastic period. Ceramics from [ADD IN REVIEW ] have been examined, with three phases being established: late Naqada III, First Intermediate Period, and the mediaeval Islamic period. Absolute dates have been determined for each phase and, where comparison is possible, have been found in good agreement with the historical chronology. A set of vessels from Naqada, Ballas, and the Tomb of Djer at Abydos have been examined using OSL in conjunction with radiocarbon dating. Again, three phases of activity were discerned: late Naqada II, early Naqada III, and the first scientifically determined dates for a burning event in the Tomb of Djer (the New Kingdom). The thesis also demonstrates how OSL can be used as a relative dating technique by analysing a collection of Wavy-Handled ceramics and wine jars from Turah, finding that the OSL results agree well with the established relative chronology. Finally, this thesis has also examined the applicability of cladistic analysis to the study of Egyptian ceramics. Cladistics is a technique borrowed from the biological sciences which offers a complimentary way to examine the evolution of ceramic types and forms, in particular the development of beer and wine jars.

Page generated in 0.0849 seconds