• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 76
  • 55
  • 53
  • 47
  • 43
  • 30
  • 27
  • 21
  • 18
  • 16
  • 12
  • 12
  • 12
  • 12
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores : estudo prospectivo /

Arantes, Flávia de Moraes. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Francisco Antônio Bertoz / Banca: Júlio de Araújo Gurgel / Banca: José Rino Neto / Banca: Marcos Roberto de Freitas / Resumo: A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba - UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste "t" pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste "t" de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba - UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages "Beginning" and "After", a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student's t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below) / Doutor
42

Comparação quantitativa da retração de caninos superiores utilizando dois sistemas de ancoragem /

Kina, Juliana. January 2009 (has links)
Orientador: Eduardo César Almada Santos / Banca: Marcos Rogério de Mendonça / Banca: João Batista de Paiva / Resumo: Introdução: Para a eficiência da ancoragem, diferentes protocolos são preconizados durante a mecânica ortodôntica, principalmente quando se deseja a retração inicial do canino para o alinhamento e nivelamento anterior sem a mesialização do segmento posterior. Nesse contexto, a utilização dos minimplantes tem sido cada vez mais frequente, pois possuem características desejáveis para essa finalidade como a facilidade operacional de sua instalação, dispensa a colaboração do paciente para o desenvolvimento da mecânica ortodôntica,é favorável na estética e permite um sistema de forças mais previsível. O objetivo deste trabalho foi comparar quantitativamente por meio de telerradiografias em norma lateral e radiografias panorâmicas, a taxa de retração inicial de caninos (RIC) superiores, utilizando-se dois sistemas distintos de ancoragem. Métodos: Foram selecionados 18 pacientes, formando dois grupos aleatórios de 9 indivíduos (G1 e G2), triados para tratamento ortodôntico na UNESP - Araçatuba. Como ancoragem foi utilizado minimplantes no grupo G1 e botão de Nance no grupo G2. Para todos os pacientes foram realizadas duas telerradiografias em norma lateral (T1 e T2) e duas panorâmicas (P1 e P2). Para comparação entre as fases Início (antes do tratamento) e Após (após a retração inicial de caninos) foi utilizado o teste t pareado. Para a comparação entre os grupos de minimplante e botão de Nance foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Resultados: Para a RIC no Grupo G1, obteve-se uma média de 0,63 mm/mês, enquanto para o grupo G2 a média foi de 0,56 mm/mês. Conclusões: A análise das telerradiografias em norma lateral e das radiografias panorâmicas revelou a inexistência de diferença estatisticamente significante entre os dois grupos. / Abstract: Introduction: For efficiency of the anchorage, different protocols are recommended during orthodontic mechanics, especially when clinicians want to retract the initial alignment and leveling without the inclination of the posterior segment. In this context, the use of mini-implants has been frequent. For this purpose it has desirable characteristics, such as the operational facility of installation, the collaboration of the patient, exemption for the development of orthodontic mechanics, it is favorable in appearance and allows more predictable system forces. This study compared, by teleradiographs and panoramic radiographs, the initial rate of retraction of canines (ICR), using two different systems of anchoring. Methods: 18 patients were selected and divided in two random groups of 9 subjects (G1 and G2). They needed and were refered to orthodontic treatment at UNESP - Araçatuba. In G1, mini-implants were used as anchor and G2 used the Nance button appliance. Two teleradiographs (T1 and T2) and two panoramic (P1 and P2) were made for all patients. The paired T test was used for comparison between Initial (before treatment) and After (after the initial retraction of canines) phases. Student's t test for independent measures was used for comparison between groups of mini-implants and the Nance button appliance. A significance level of 5% (p <0.05) was adopted in all tests. Results: For G1, an average of 0.63 mm / month was obtained, while for G2, the average was 0.56 mm / month. Conclusions: The analysis of teleradiographs and panoramic radiographs showed the absence of statistically significant difference between the two groups. / Mestre
43

Comparação tridimensional dos efeitos dentários de duas mecânicas para fechamento de espaço: estudo preliminar / Three-dimensional comparison of dental effects of two mechanics for space closure: a preliminary study

Camila de Sousa Dardengo 17 December 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As más oclusões de Classe I com biprotrusão dentária são caracterizadas pela projeção dos incisivos superiores e inferiores e podem ser corrigidas com extrações de primeiros pré-molares, permitindo reposicionar os incisivos, usando como ancoragem os dentes posteriores. Esse trabalho teve como objetivo comparar, por meio de superposição de modelos tridimensionais, a movimentação de molares e de incisivos com duas técnicas para fechamento de espaços. Foram selecionados, tomografados (T0) e distribuídos, aleatoriamente em dois grupos, seis pacientes com indicação de exodontia de quatro primeiros pré-molares. No grupo 1 (n=3) foi feito o fechamento dos espaços das extrações em uma única etapa (fechamento em massa) e no grupo 2 (n=3), em duas etapas (distalização de caninos seguida da retração de incisivos). Após o completo fechamento dos espaços foi solicitada nova tomografia (T1). Os modelos tridimensionais em T0 e T1 para os dois grupos foram superpostos para descrever e quantificar a movimentação ocorrida nos primeiros molares. A retração de incisivos foi avaliada de maneira bidimensional. Os molares superiores e inferiores do grupo 1 sofreram movimentação mesial de translação, enquanto os do grupo 2, apresentaram deslocamento de coroa maior do que de ápice radicular, demonstrando movimento de inclinação mesial de coroa. Ao se comparar o movimento mesial dos molares entre os dois grupos, observou-se que no grupo 1 houve maior movimentação mesial da raiz mésio-vestibular dos molares superiores (p=0,009). No entanto, em ambos os grupos os molares superiores giraram sobre a raiz palatina. No arco inferior verificou-se maior movimento mesial de coroa para o grupo 2 (p=0,015). A análise da movimentação dos incisivos apresentou variações semelhantes para as medidas lineares e angulares dos incisivos superiores nos dois grupos. Já, para as medidas angulares dos incisivos inferiores, observou-se que o grupo 1 apresentou menor controle de torque. O tempo de tratamento de todos os pacientes da amostra foi superior a 30 meses, exceto um paciente que apresentou tempo de tratamento inferior a 24 meses. Pôde-se concluir que a perda de ancoragem ocorreu por movimento de translação no fechamento de espaços em massa, e por inclinação mesial no fechamento de espaços em duas etapas, para ambos os arcos. Parece haver maior movimentação mesial radicular nos molares superiores no fechamento em massa e maior movimento mesial de coroa dos molares inferiores para o fechamento em duas etapas. Sugere-se que não há diferença na retração dos incisivos superiores e maior retroinclinação dos incisivos inferiores no fechamento de espaços em duas etapas. / Class I malocclusions with dental biprotrusion are characterized by the projection of upper and lower incisors and can be corrected with extractions of four first premolars, allowing incisor retraction using the posterior teeth as anchorage. The purpose of this research was to compare the movement of molars and incisors, by superimpostions of three-dimensional models, with two space closure techniques. Six patients with indication for four first premolar extractions were selected, tomographed (T0) and randomly assigned to two groups. For Group 1 (n=3) premolar extraction space closure was performed in one-stage (en masse retraction) and for group 2 (n=3) in two stages (canine retraction followed by incisor retraction). After complete space closure, a new tomograph was taken (T1). The three-dimensional models, in T0 and T1, for both groups were superimposed to describe and quantify first molar movement. Incisor retraction was evaluated in two dimensions. The upper and lower molars in group 1 presented bodily mesial movement, while those in group 2, presented greater crown than root movement, demonstrating mesial crown tipping. When the amount of mesial molar movement was compared between the two groups, a greater mesial root movement was observed for upper molars in group 1 (p=0.009). However, in both groups the upper molars rotated aroung the palatal root. In the lower arch, a greater mesial crown movement was observed in group 2 (p=0.015). Incisor movement analysis presented similar variations for linear and angular measurements for upper incisors in both groups. In contrast, the angular measurements for the lower incisors demonstrated more torque control in group 2. The treatment time for all patients in the sample was greater than 30 months, with the exception of one patient, who presented treatment time smaller than 24 months. In conclusion, anchorage loss ocurred by bodily movement in en masse space closure and by mesial crown tipping in two-stage space closure, in both arches. In addition, there might be greater mesial root movement for upper molars in en masse space closure and greater mesial crown movement in two-stage space closure. It can also be suggested that there are no differences in upper incisor retraction and there is greater lower incisor uprighting in two-stage space closure.
44

Alteração do volume de fluido gengival de pacientes com periodontite crônica em manutenção periodontal sob tratamento ortodôntico: estudo piloto / Change in the amount of gingival crevicular fluid of patients with chronic periodontitis in periodontal maintenance under orthodontic treatment: a pilot study

Rivail Antonio Sergio Fedel Junior 26 February 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do estudo foi mensurar as alterações na quantidade do volume de fluido gengival (FG) dos dentes submetidos à movimentação ortodôntica, em adultos com periodontite crônica na fase de manutenção periodontal. O FG foi coletado com uma tira de papel absorvente padrão das áreas de pressão dos dentes de 10 pacientes (sete homens e três mulheres) e medido em microlitro no Periotron em seis dias distintos (dia -7, dia 0, dia 1, dia 7, dia 14 e dia 21). Os pacientes foram submetidos a um rigoroso programa de controle de placa. O teste de Wilcoxon foi aplicado para comparar os dados obtidos. Os resultados mostraram que o controle de placa efetivo baixou a quantidade de FG do dia -7 para o dia 0, e em seguida houve uma elevação do FG até o dia 7 por conta do início da movimentação ortodôntica, e uma nova queda do dia 7 até o 21. O maior volume de FG foi encontrado no dia 7, uma semana após o início da movimentação. O menor volume no dia 0. Concluindo, a movimentação ortodôntica aumentou o volume de FG do dia 0 até o dia 7. / The aim of this study was to measure the alterations in the amount of gingival crevicular fluid (GCF) of teeth during orthodontic tooth movement in adults with chronic periodontitis under a periodontal maintenance program. The GCF was collected with paper stripes from pression sides of teeth in 10 patients (7 males and 3 females) and measured in microlitres on Periotron in six distinct periods of time (day -7, day 0, day 1, day 7, day 14, day 21). Patients were under supervised program of plaque control. Wilcoxon test was applied to compare the data. The results shown that the effective plaque control reduces the amount of GCF from day -7 to day 0, followed by an elevation until day 7 after the beginning of orthodontic tooth movement and a new reduce from day 7 to 21. The highest amount of GCF was found on day 7, one week after the beginning of tooth movement, while the smallest found on day 0.
45

Influência do padrão de crescimento sobre a espessura da cortical óssea alveolar e sua correlação com a estabilidade dos mini-implantes / Influence of growth pattern on the alveolar cortical bone thickness and the correlation with stability of mini-implants

Carolina Carmo de Menezes 18 February 2011 (has links)
O objetivo deste estudo foi avaliar a influência do padrão de crescimento craniofacial na espessura da cortical óssea alveolar e correlacioná-lo com a estabilidade dos mini-implantes ortodônticos. A amostra constituiu de 30 pacientes com 56 mini-implantes inseridos na região posterior vestibular da maxila como recurso de ancoragem na retração anterior. Inicialmente, os pacientes foram divididos de acordo com a média do ângulo FMA, em padrão de crescimento horizontal (grupo GH) e vertical (grupo GV). As espessuras das corticais ósseas foram mensuradas nos cortes axiais das imagens de tomografia computadorizada de feixe cônico. As médias econtradas em cada grupo foram comparadas pelo teste t. A correlação de Pearson foi realizada entre os valores do ângulo FMA e as espessuras das corticais ósseas. Posteriormente, para avaliar a influência do padrão de crescimento sobre a estabilidade dos mini-implantes, estes foram divididos em dois grupos também de acordo com o padrão de crescimento: GMI(H) horizontal e GMI(V) vertical. Os grupos foram comparados quanto ao grau de mobilidade e a proporção de sucesso dos mini-implantes pelos testes de Mann-Whitney e o teste Exato de Fisher. Através desses testes e do teste Qui-quadrado foi avaliada a influência das seguintes variáveis sobre o grau de estabilidade: características do tecido mole na região de inserção, sensibilidade, a quantidade de placa, o período de observação e a técnica utilizada para cada dispositivo. Os resultados obtidos demonstraram que a espessura da cortical óssea alveolar anterior (superior e inferior) e posterior (inferior) vestibulares foram maiores no grupo GH do que o grupo GV. Houve correlação negativa significante entre o FMA e as espessuras nas regiões anteriores inferiores (vestibular e lingual) e superior (vestibular). Não houve diferença significante nos resultados para o grau de mobilidade e proporção de sucesso dos mini-implantes nos grupos GMI(H) e GMI(V). O tempo médio de observação foi de 8,77 meses. A proporção de sucesso total foi de 89,29% e nenhuma variável mostrou estar relacionada com o sucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujo mini-implante apresentava mobilidade e a falha desses dispositivos de ancoragem ocorria logo após sua inserção. / This study aimed the assessment of the craniofacial growth pattern influence on the alveolar bone cortical thickness as well as the evaluation of the stability of orthodontic mini-implants. The sample comprised 56 mini-implants inserted on the posterior buccal region of the maxilla of 30 patients with the purpose of orthodontic anchorage for the anterior retraction. Initially, patients were divided by FMA mean according to the growth pattern as: horizontal group (GH group) and vertical group (GV group). The alveolar cortical bone thicknesses were measured in the axial sections of the images of cone-beam computed tomography. The means found for each group were compared with the t test. Pearson´s correlation was performed for the values of growth pattern (FMA) and for the thicknesses of cortical bone. In order to evaluate the influence of growth pattern on the stability of mini-implants, these devices were divided in two other groups, according to the growth pattern as: GMI(H), horizontal and GMI(V), vertical. The mobility degree and success rate of mini-implants shown by these two groups were compared using Mann-Whitney tests and Fisher Exact test. Through these tests and the Chi-square test the influence of the following variables on the degree of stability were evaluated: soft tissue characteristics of the insertion site, sensibility degree, plaque retention around miniimplant, observation period and technique used. The results demonstrated that the thickness of the anterior buccal cortical bone (upper and lower) and the posterior cortical bone (lower) were greater for the GH group than for the GV group. There was a significant negative correlation between the FMA and the thicknesses of the lower anterior regions (buccal and lingual) and upper regions (buccal). No significant difference was found regarding the mobility degree and the success rate of miniimplants between the groups GMI(H) and GMI(V). Total success rate found was 89.29% and no variable showed to be related to the success of mini-implants. Nevertheless, a greater sensibility was observed in patients whose mini-implants presented mobility and the failure of these anchorage devices occurred in a short time after insertion.
46

Avaliação da resistência a corrosão e da microestrutura de superfície de mini-implantes ortodônticos utilizados

Caetano, Paula Liparini 21 November 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-10T11:50:34Z No. of bitstreams: 1 paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor verificar se Márcio realmente não tem acento - Primeiro Orientador: Campos, Marcio José da Silva Favor corrigir o sobrenome composto: Sotto-Maior, Bruno Salles Favor ferificar de Sérgio realmente não tem acento: Membro da banca: Mota Júnior, Sergio Lu on 2018-01-23T11:42:27Z (GMT) / Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-23T13:05:31Z No. of bitstreams: 1 paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-24T13:32:58Z (GMT) No. of bitstreams: 1 paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) / Made available in DSpace on 2018-01-24T13:32:58Z (GMT). No. of bitstreams: 1 paulaliparinicaetano.pdf: 1378622 bytes, checksum: 516787f8df7e62897eb86e9b55568c88 (MD5) Previous issue date: 2017-11-21 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Introdução: Os mini-implantes ortodônticos, como biomateriais, devem possuir, além de resistência mecânica, boa resistência à corrosão no meio fisiológico o qual estão inseridos. Objetivo: Avaliar a resistência à corrosão e a microestrutura de superfície de mini-implantes ortodônticos mantidos em seus sítios ósseos de inserção e removidos após sua utilização. Material e métodos: Foram avaliados vinte mini-implantes ortodônticos autoperfurantes de liga Ti6AI4V, divididos em 2 grupos de 10 unidades: grupo controle (como recebidos do fabricante) e grupo teste (que permaneceram estáveis em seus sítios ósseos de inserção e que foram removidos após sua utilização). Foi realizada a análise visual da superfície da rosca dos mini-implantes com microscópio eletrônico de varredura (MEV) e a avaliação da resistência à corrosão com o ensaio de polarização cíclica potenciodinâmica, onde foram determinados o OCP (potencial de circuito aberto), o tOCP (tempo de OCP), a ipp (corrente de passivação primária) e a Epp (potencial de passivação primário). Resultados: Não foi identificada diferença significativa entre os grupos para as variáveis estudadas, apesar de a comparação entre os valores de OCP ter tido um p-valor limite (p=0,050). As imagens de MEV da superfície de rosca dos mini-implantes do grupo controle e grupo teste obtidas demonstraram uma superfície polida e regular, sem presença de manchas ou partículas aderidas. Apenas um mini-implante do grupo controle apresentou em técnica auxiliar de espectrometria de energia dispersiva de raio-X (EDS) uma redução de 61% da concentração de titânio no interior da cavidade em relação à superfície do mini-implante), confirmando a imagem da microscopia eletrônica de varredura, a presença de um pite proveniente do processo de corrosão. Conclusão: A permanência média de 230 dias de mini-implantes ortodônticos fabricados com liga Ti6Al4V nos sítios ósseos de inserção não causou alterações significativas na resistência à corrosão e nas características superficiais destes dispositivos. / Introduction: The orthodontic mini-implants as biomaterials, in addition to mechanical resistance, shall have good corrosion resistance in the physiological environment in which they are inserted. Objective: To assess the corrosion resistance and the surface microstructure of orthodontic mini-implants kept in their bone insertion sites and removed after use. Material and methods: Twenty orthodontic mini-screw-implants made from Ti6AI4V alloy were assessed; divided into 2 groups of 10 units: the control group (as-received from the manufacturer) and the test group (which remained stable in their bone insertion sites and that have been removed after use). The visual analysis of the thread surface of mini-implants was performed with a scanning electron microscope (SEM) and the evaluation of corrosion resistance with the cyclic potentiodynamic polarisation test through which the open circuit potential (OCP), the tOCP (timing of OCP), the primary passivation current (ipp) and the primary passivation potential (Epp) were determined. Results: It has not been identified any significant difference between the groups for the studied variables, although the comparison between the OCP values has had a p-limit value (p = 0.050). SEM images of the thread surface of the mini-implants obtained from both groups showed a regular polished surface without the presence of stains or adhered particles. Only one mini-implant from the control group showed a 61% reduction in the concentration of titanium within the cavity compared to the surface of the mini-implant through an auxiliary spectrometry technique of energy dispersive x-ray (EDX), confirming the scanning electron microscopic image that shows the presence of pit from the corrosion process. Conclusion: The average stay of 230 days of orthodontic mini-implants made from Ti6Al4V alloy at bone insertion sites did not cause significant changes either in corrosion resistance nor superficial characteristics of these devices.
47

Estudo da expressão das moléculas reguladoras da remodelação do osso alveolar durante a movimentação ortodôntica com força contínua em ratos tratados com alendronato sódico / Study of expression of regulatory molecules of the alveolar bone remodeling during orthodontic movement with continuous force in rats treated with alendronate

Natasha D'Andrea Mateus Marques 19 October 2015 (has links)
A movimentação dentária ortodôntica ocorre através de dois processos, nos quais o osso alveolar é reabsorvido nas áreas de pressão, enquanto que novo osso é formado na área de tração. O processo de reabsorção óssea ocorre pela ação de células multinucleadas, os osteoclastos. Os bisfosfonatos constituem um grupo de fármacos com propriedade de inibir a reabsorção óssea, foi utilizado no presente estudo com a finalidade de interferir na remodelação óssea induzida ortodonticamente. Para isso, força contínua de 15 cN foi aplicada aos primeiros molares superiores de ratos machos Wistar de 2 1/2 meses, utilizando uma biomecânica com fios superelásticos. Os animais foram divididos aleatoriamente em 4 grupos: 1) O grupo controle constituído por dezoito ratos, os quais foram injetados solução salina por 7 dias antes da instalação da biomecânica passiva, que permaneceu por 3, 10 e 18 dias; 2) Dezoito animais foram tratados com ALN (dose 2,5 mg/Kg) por 7 dias antes da instalação da biomecânica passiva que permaneceu por 3, 10 e 18 dias; 3) Dezoito animais foram tratados com alendronato com a mesma dose citada acima por 7 dias antes da instalação da biomecânica ativa que permaneceu por 3, 10 e 18 dias; 4) Dezoito animais foram injetados com solução salina 7 dias antes da instalação da biomecânica ativa que permaneceu por 3, 10 e 18 dias. As maxilas foram fixadas com 4% de formaldeído + 0,1% de glutaraldeído, descalcificadas em EDTA a 4,13% e incluídas em parafina ou resina Spurr. Os cortes foram corados com HE para análise morfológica. Alguns cortes foram submetidos à imuno-histoquímica para detecção de RANKL e OPG. Foi utilizado o método TRAP, marcador de osteoclastos e microscopia eletrônica de transmissão para análise ultraestrutural. Alguns espécimes tiveram a cortical óssea vestibular do primeiro molar superior congelada em nitrogênio líquido para análise da expressão de RANKL por Western Blotting. O ALN inibiu a reabsorção óssea e radicular de todos os grupos tratados. As células clásticas apresentaram-se em estado latente. No grupo da movimentação ortodôntica o osso alveolar foi remodelado e com 18 dias a superfície radicular apresentou-se reabsorvida e o TRAP revelou clastos ativos, achados confirmados pela microscopia eletrônica de transmissão. A expressão de RANKL, molécula ativadora de células clásticas, nao foi inibida pela droga. A expressão de OPG foi aumentada nos animais tratados. Os resultados demonstram que o uso de alendronato sódico na movimentação ortodôntica não interfere no recrutamento dos osteoclasto, ele aparentemente inibe sua ativação, o que pode interferir no processo de remodelação óssea e talvez diminua a quantidade de movimentação dentária. / Orthodontic tooth movement occurs through two processes in which the alveolar bone is resorbed in the pressure areas, whereas new bone is formed in the tension area. The bone resorption occurs by multinucleated cell, the osteoclasts. The bisphosphonates are drugs with capability to inhibit clastic activity were used in the present study in order to interfere with the bone remodeling induced orthodontic. For this continuous force of 15 cN was applied to the first molars of Wistar male rats of 2 1/2 months, using a biomechanical with superelastic wire. The animals were randomly divided into 4 groups: 1) The control group consisted of eighteen mice, which received sterile saline solution saline for 7 days prior to installation of passive biomechanics, which remained for 3, 10 and 18 days; 2) Eighteen animals were treated with ALN (dose 2.5 mg / kg) for 7 days prior to installation of the passive biomechanical to remain for 3, 10 and 18 days; 3) Eighteen animals were treated with alendronate with the same dose quoted above for 7 days prior to the biomechanical installation that remains active for 3, 10 and 18 days; 4) Eighteen animals were injected with sterile saline solution 7 days prior to the biomechanical installation that remains active for 3, 10 and 18 days. The maxillae were fixed with 4% formaldehyde + 0.1% glutaraldehyde, decalcified in EDTA 4.13% and embedded in paraffin or Spurr resin. The specimens were morphologically analyzed in HE stained sections. Some stained sections were used for immunolabeling for RANKL and OPG. The osteoclasts were marked by tartrate-resistant acid phosphatase (TRAP) histochemistry. The ultrathin sections were examined in a trasnmission electron micrsocpe. Some specimens were frozen in liquid nitrogen for protein extraction and Western Blotting protein expression analyzes. The ALN inhibited bone resorption and root of all the treated groups. The clastic cells present in a latent state. In the orthodontic movement group alveolar bone was remodeled with 18 days to root surface presented itself reabsorbed and the TRAP revealed clasts assets, findings confirmed by transmission electron microscopy. Expression of RANKL activating molecule clastic cells was not inhibited by the drug. The OPG expression was increased in treated animals. The results demonstrate that the use of alendronate in the orthodontic movement does not interfere with osteoclast recruitment, it apparently inhibits their activation, which can interfere in the bone remodeling process and may reduce the amount of tooth movement.
48

Monitoramento histológico, histomorfométrico e radiográfico da cicatrização óssea ao redor de mini-parafusos ortodônticos autoperfurantes, submetidos ou não à aplicação de carga imediata, em tíbias de coelhos / Histological, histomorphometric and radiographic monitoring of bone healing around self-drilling orthodontic mini-screws, subjected or not to immediate load in rabbit tibiae

Priscilla Campanatti Chibebe Catharino 25 May 2012 (has links)
Mini-implantes ortodônticos são acessórios de ancoragem esquelética. O objetivo deste estudo foi descrever a cicatrização óssea inicial ao redor dos mini-implantes, esterilizados pelos pesquisadores, submetidos ou não à aplicação de carga imediata. Foram inseridos 144 mini-implantes autoperfurantes (TOMAS®, Dentaurum, Germany) nas tíbias de dezoito coelhos brancos. Carga imediata (50 cN) foi aplicada sobre 50% dos mini-implantes. Quatro coelhos foram sacrificados em cada tempo pós-cirúrgico: dias 15, 21, 30 e 60, e dois no dia 0, constituindo grupo controle. Radiografias digitais foram obtidas para mensuração da espessura da cortical óssea (ECO), contíguo aos mini-implantes e equidistante deles. Nas imagens digitais das lâminas histológicas, realizou-se análise histológica e histomorfométrica. Quantidade de osso (QO), contato osso-implante (BIC) e ECO foram analisados pelos testes t-pareado, ANOVA e coeficiente de correlação de Pearson. Aos 0 e 15 dias haviam áreas de fraturas da borda da cortical. Após 30 dias houve deposição de osso imaturo, que se apresentou maduro aos 60 dias. QO foi maior com carga aos 15 dias (p = 0,034); e aumentou ao longo da cicatrização, nos grupos com (p =0,004) e sem carga (p<0,001). Carga não afetou BIC; os valores aumentaram no decorrer do tempo, nos grupos com (p<0,001) e sem carga (p=0,001). ECO aumentou em todas as regiões (p<0,001). ECO próximo aos miniimplantes foi maior que no ponto médio, exceto aos 15 dias sem carga (p = 0.077). Concluiu-se que carga imediata leve não comprometeu a cicatrização óssea ao redor dos mini-implantes. Ósseointegração e o aumento da espessura da cortical óssea foram tempo-dependentes. / Mini-implants are attachments for orthodontic anchorage. This study aimed to describe the initial bone healing around mini-implants sterilized by the researchers, submitted or not to application of immediate loading. Were inserted 144 self-drilling mini-implants(TOMAS®, Dentaurum, Germany) in the tibia of eighteen white rabbits. Immediate loading (50 cN) was applied to 50% of mini-implants. The animals were sacrificed at each time post-surgery: day 15, 21, 30 and 60, and two on day 0, being the control group. Digital radiographs were obtained to measure the thickness of cortical bone (ECO), adjacent to mini-implants and equidistant from them. In digital pictures from histological slides histology and histomorphometry was analyzed. Amount of bone (QO), bone-implant contact (BIC) and ECO were analyzed by paired t-test, ANOVA and coefficient of Pearson correlation. At 0 and 15 days had shear areas. After 30 days there was deposition of immature bone, which appeared mature at 60 days. QO load was greater at 15 days (p = 0.034), and increased over healing in load (p = 0.004) and unloaded groups (p <0.001). Load affected BIC, the values increased over time in groups with load (p <0.001) and unloaded (p = 0.001). ECO increased in all regions (p <0.001). ECO near the mini-implants was greater than at midpoint, except for 15 days without load (p = 0,077). It was concluded that light immediate loading did not affect bone healing around the mini-implants. Osseointegration and increased cortical bone thickness were time-dependent.
49

Avaliação das distribuições de tensões, por meio da análise de elementos finitos, em uma hemi-maxila, durante a fase de retração anterior por deslizamento, na mecânica ortodôntica / Evaluation of the tensions distributions, using the finite element analysis, in an hemi-maxilla during a sliding anterior retraction , in an orthodontic mechanics

Luiz Vicente de Moura Lopes 15 April 2011 (has links)
O objetivo deste estudo foi analisar, por meio do método dos elementos finitos, como ocorreram as distribuições de tensões nos dentes, osso e aparelho ortodôntico, durante a fase de retração por deslizamento (150g), em um caso com extrações. Simularam-se duas posições do gancho (mesial e distal de canino), duas alturas do gancho (4 e 9mm) e duas alturas posteriores (gancho do tubo do molar e no miniimplante, a 9mm do arco). A amostra consistiu do corte axial da TCFC, de uma mulher de 17 anos de idade, com dentes bem nivelados. Foi desenvolvido um modelo 3D, da geometria da hemi-maxila direita e um modelo numérico, para obter os regimes de tensões e deformações gerados em um sistema de movimentação ortodôntica, por meio do software ANSYS® versão 12.0. Os sólidos dos braquetes e do fio ortodôntico foram incluídos a partir das dimensões fornecidas pelo fabricante. A montagem de todos os componentes foi feita por meio do SolidWorks 2009 SP4.1. A partir do cálculo das respostas do modelo, às cargas a que foi submetido, verificou-se que, os dentes que sofreram maiores concentrações de tensões foram os justapostos aos ganchos, sendo mais intensas as do gancho mesial, particularmente nos incisivos laterais. Embora, a solicitação de tensões no arco tenha sido semelhante em todos os modelos, na posição distal do gancho, houve maior concentração de tensões na extensão imediatamente distal. Os modelos com ganchos de 4mm, diferente aos de 9mm, apresentaram distribuições de tensões mais uniformes, causando menos estresse aos dentes e osso e semelhante ao arco. O modelo com vetor de força direcionado do gancho da mesial do canino ao miniimplante foi o único que mostrou variações, mostrando distribuições de forças mais elevadas na região anterior e posterior ao ser comparado com o vetor de força direcionado ao tubo do primeiro molar. / The aim of this study was to evaluate, by means of finite element analysis, the tensions distrubutions on the teeth, bone and orthodontic appliance, during en-masse retraction sliding mechanics (150g), in an extraction case. It was taken into account two hook positions (mesial and distal to the canine), two hook heights (4mm and 9mm) and two posterior heights ( the first molar tube and the mini-implant, located 9mm from the archwire). The sample of this study consisted of an axial cut realized in a cone beam computed tomography of a 17 years old woman with leveling teeh. It was developed a 3D computed model of a right hemi-maxilla and a computednumerical model capable of getting the systems tensions and deformations generated from an orthodontic moviment system, through a finite element software, ANSYS® 12.0. Observing manufactores specifications, brakets and archwire solids were included in this solid geometric model. The assembly of all componentes were made though the SolidWorks 2009 SP4.1 software. The loads model responses were calculated. The bigger concentration of tension were on the teeth located between the hook. The model with the mesial hook, suffered more intense tensions, mainly on lateral incisors. Although, the tensions request on the archwire were similars in all models, when the hook was located distaly, there were more intense tensions in its immediately distal extension. The 4mm hook models, compared with the 9mm, presented more uniform tensions distribution causing less stress to the teeth and bone and similar to the archwire. The only model that demonstrated variations, was the model with the vector force from the mesial hook and to the mini-implant. This model, demostrated higher tensions distributions on the anterior and posterior region if compared to the first molar tube vector force.
50

Avaliação tomográfica da expansão rápida da maxila assistida por mini-implantes ortodônticos em indivíduos com maturação óssea avançada. /

Oliveira, Cibele Braga January 2019 (has links)
Orientador: Ary dos Santos-Pinto / Resumo: Este estudo clínico retrospectivo pesquisou, em uma amostra de pacientes com maturação óssea avançada, as alterações esqueléticas e dentárias produzidas com a técnica de expansão rápida da maxila assistida por mini-implantes ortodônticos (MARPE) e comparou com as alterações da expansão rápida maxila assistida cirurgicamente (SARPE). Foi pesquisada também a correlação entre o grau de maturação da sutura palatina mediana (SPM), gênero e idade, com os resultados (sucesso ou insucesso) gerados com a técnica MARPE. Por último, em uma amostra maior de 85 pacientes entre 15 e 58 anos de idade, observou-se a prevalência, por gênero e período etário, dos estágios de maturação da sutura palatina mediana. Para o primeiro objetivo, uma amostra de 17 indivíduos tratados com a MARPE foi comparada com outra amostra de 15 pacientes, com faixa etária semelhante, tratados por meio da SARPE. Tomografia Computadorizada de Feixe Cônico antes(T0) e após(T1) a expansão foram avaliadas. Para o segundo objetivo, a mesma amostra da MARPE foi usada para avaliar as alterações esqueléticas observadas na T0 e T1. Imagens do plano axial da SPM foram extraídas da T0 e classificadas em um dos cinco estágios de maturação sutural. Foi avaliada a taxa de sucesso e insucesso quanto aos fatores idade, gênero e maturação sutural. E, para o terceiro objetivo, foram classificadas imagens axiais de SPM de 85 indivíduos entre 15 e 58 anos, para determinar a prevalência da maturação da SPM em relação ao gênero e idade.... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In a sample of patients with advanced bone maturation, this retrospective clinical study investigated the skeletal and dental changes produced by mini-implants assisted rapid palatal expansion (MARPE) compared with the changes in the surgically assisted rapid palatal expansion (SARPE). The correlation between the maturation stage of the midpalatal suture (MPS), sex and age was also investigated, with the results (success or failure) generated with MARPE. At last, in a larger sample of 85 patients between 15 and 58 years of age, the prevalence of maturation stages of the MPS was observed by sex and age period. For the first objective, a sample of 17 individuals, treated with MARPE, was compared with another sample of 15 patients with similar age group, treated with SARPE. CBCT before (T0) and after (T1) expansion were evaluated. For the second objective, the sample MARPE was used to evaluate the skeletal changes observed in T0 and T1. Images of the axial plane of MPS were extracted from T0 and classified into one of the five stages of suture maturation. The success rate and failure by age, sex and suture maturation were evaluated. And for the third objective, MPS axial images of 85 individuals, aged 15 to 58 years, were classified to determine the prevalence of maturation of MPS in relation to sex and age. The results showed that there is a wide variation in relation to the maturation stage of MPS founded in late adolescents and adults. MARPE showed to be a procedure with good... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0604 seconds