• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 76
  • 55
  • 53
  • 47
  • 43
  • 30
  • 27
  • 21
  • 18
  • 16
  • 12
  • 12
  • 12
  • 12
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

AVALIAÇÃO DAS ALTERAÇÕES DENTÁRIAS E ESQUELÉTICAS APÓS A DISTALIZAÇÃO DE MOLARES SUPERIORES COM APARELHO PÊNDULO SOB A INFLUÊNCIA DO LASER DE BAIXA INTENSIDADE

Francio, Fabíola 27 March 2012 (has links)
Made available in DSpace on 2016-08-03T16:30:59Z (GMT). No. of bitstreams: 1 Fabiola Francio.pdf: 1460992 bytes, checksum: c93aa096d8df456fe5658fd3ca34579e (MD5) Previous issue date: 2012-03-27 / This study evaluated the rate of orthodontic movement, and dental/skeletal effects in distalization of maxillary molars under the influence of low intensity laser using cephalometric radiographs. The sample was composed of 18 patients with Class II malocclusion, initial mean aged of 14,4 years and divided into two groups: Group I - laser and Group II - control. Patients were treated with modified Hilgers Pendulum orthodontic appliance, at the same time low intensity laser was applied to the right and left sides, to the root region of the first and second molars; in nine patients of the sample; by the protocol: 780nm wavelength, 40mW power, 10J/cm² energy density, 0.4J power for 10 seconds per point an each point resulting in a total energy of 20.8J. Fifty-two points were distributed in the buccal and palatal side of the first and second upper molars. Laser treatment was performed on the activation of TMA spring and repeated every month until over correction of molar ratio. The lateral radiographs were done at initiation of treatment (T1), at final of third month (T2) and at the end of molar distalization (T3) with over correction by approximately 1mm. Cephalometric analyses were done to compare the initial (T1) and final (T3) stage and Initial (T1) and third month (T2) stage and to compare between groups. The results showed distal tipping of the first and second molars, buccal inclination of the upper central incisors accentuated by the presence of the second molars and absence of significant vertical dental changes. The mandibular plane moved clockwise, consequently increasing lower anterior facial height. It was concluded that the changes introduced by modified Hilgers Pendulum appliance were predominantly dento alveolar and the effect of laser therapy did not show significant statistically difference in the speed of orthodontic tooth movement of the first and second molars and, neither, on the variables studied. / O presente estudo avaliou a velocidade da movimentação ortodôntica e as alterações dentárias e esqueléticas na distalização de molares superiores sob influência do laser de baixa intensidade por meio de telerradiografias laterais. A amostra foi constituída por 18 pacientes, portadores de maloclusão Classe II, com idade média inicial de 14,4 anos e divididos em dois grupos: Grupo I - laser e Grupo II - controle. Os pacientes foram tratados com um dispositivo ortodôntico denominado Pêndulo de Hilgers modificado, concomitantemente foi realizado a aplicação do laser de baixa intensidade na região radicular dos primeiros e segundos molares superiores, dos lados direito e esquerdo, nos pacientes do grupo I, sob o seguinte protocolo: 780nm de comprimento de onda, 40mW de potência, 10J/cm² de densidade de energia, 0,4J de energia por ponto durante 10 segundos cada e resultando em energia total de 20,8J. Foram distribuídos 52 pontos por vestibular e palatina dos primeiros e segundos molares superiores. A aplicação do laser foi realizada no dia da ativação da mola de TMA e repetida a cada mês até a sobrecorreção da relação molar. As telerradiografias laterais foram realizadas no início do tratamento (T1), ao final do terceiro mês (T2) e ao final da distalização (T3) com a relação molar sobrecorrigida em aproximadamente 1mm. Após análise cefalométrica foram realizadas comparações das alterações obtidas entre as fases Inicial (T1) e Final (T3) e Inicial (T1) e terceiro mês (T2) e comparadas entre os grupos. Os resultados mostraram inclinação para distal dos primeiros e segundos molares superiores, inclinação vestibular dos incisivos centrais superiores acentuada pela presença dos segundos molares e ausência de alterações dentárias verticais significativas, rotação do plano mandibular no sentido horário e o consequente aumento da altura facial anterior inferior. Concluiu-se que os efeitos do Pêndulo de Hilgers modificado sob a metodologia realizada provocaram alterações predominantemente dentoalveolares e que a movimentação dos primeiros e segundos molares superiores sob efeito da laserterapia, não apresentou diferença estatisticamente significante na velocidade de movimentação ortodôntica e em nenhuma das variáveis estudadas.
32

Influência do laser de baixa intensidade na movimentação e na ancoragem ortodôntica por meio de tomografia computadorizada

Orlando, Franciele 16 April 2010 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 Franciele Orlando.pdf: 1490020 bytes, checksum: 40d5c7d224cda3e96aa6290e53a2447c (MD5) Previous issue date: 2010-04-16 / Este estudo avaliou os efeitos do laser de baixa intensidade na velocidade de movimentação ortodôntica dos caninos durante a fase de retratação e na ancoragem dos molares por meio de tomografia computadorizada de feixe cônico. Foram selecionados 21 pacientes que necessitavam de extração de primeiros pré-molares sendo que 15 apresentavam maloclusão de classe I de Angle e 6 classe II de Angle. Foram avaliados 72 caninos e 72 molares , sendo 72 molares, sendo 42 caninos e 42 molares superiores, e 30 caninos e 30 molares inferiores. A retratação inicial dos caninos foi realizada com arco segmentado 0,014, por mio de mola de níquel titâneo com uma força de 150 g. Um dos caninos foi irradiado com laser de diodo, com o protocolo de aplicação de 0nm/40mW/10J/cm2/04,J por ponto, sendo cinco pontos por vestibular e cinco pontos por lingual na região radicular , totalizando Et=4J. Esta aplicação foi realizada no dia em que foi ativada a mola de retratação, sendo que no canino contralateral foi realizada uma simulação (placebo). Decorridos trinta dias em média, houve nova ativação da mola e aplicação do laser no mesmo canino já irradiado.(AU)
33

Comparação tridimensional dos efeitos dentários de duas mecânicas para fechamento de espaço: estudo preliminar / Three-dimensional comparison of dental effects of two mechanics for space closure: a preliminary study

Camila de Sousa Dardengo 17 December 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As más oclusões de Classe I com biprotrusão dentária são caracterizadas pela projeção dos incisivos superiores e inferiores e podem ser corrigidas com extrações de primeiros pré-molares, permitindo reposicionar os incisivos, usando como ancoragem os dentes posteriores. Esse trabalho teve como objetivo comparar, por meio de superposição de modelos tridimensionais, a movimentação de molares e de incisivos com duas técnicas para fechamento de espaços. Foram selecionados, tomografados (T0) e distribuídos, aleatoriamente em dois grupos, seis pacientes com indicação de exodontia de quatro primeiros pré-molares. No grupo 1 (n=3) foi feito o fechamento dos espaços das extrações em uma única etapa (fechamento em massa) e no grupo 2 (n=3), em duas etapas (distalização de caninos seguida da retração de incisivos). Após o completo fechamento dos espaços foi solicitada nova tomografia (T1). Os modelos tridimensionais em T0 e T1 para os dois grupos foram superpostos para descrever e quantificar a movimentação ocorrida nos primeiros molares. A retração de incisivos foi avaliada de maneira bidimensional. Os molares superiores e inferiores do grupo 1 sofreram movimentação mesial de translação, enquanto os do grupo 2, apresentaram deslocamento de coroa maior do que de ápice radicular, demonstrando movimento de inclinação mesial de coroa. Ao se comparar o movimento mesial dos molares entre os dois grupos, observou-se que no grupo 1 houve maior movimentação mesial da raiz mésio-vestibular dos molares superiores (p=0,009). No entanto, em ambos os grupos os molares superiores giraram sobre a raiz palatina. No arco inferior verificou-se maior movimento mesial de coroa para o grupo 2 (p=0,015). A análise da movimentação dos incisivos apresentou variações semelhantes para as medidas lineares e angulares dos incisivos superiores nos dois grupos. Já, para as medidas angulares dos incisivos inferiores, observou-se que o grupo 1 apresentou menor controle de torque. O tempo de tratamento de todos os pacientes da amostra foi superior a 30 meses, exceto um paciente que apresentou tempo de tratamento inferior a 24 meses. Pôde-se concluir que a perda de ancoragem ocorreu por movimento de translação no fechamento de espaços em massa, e por inclinação mesial no fechamento de espaços em duas etapas, para ambos os arcos. Parece haver maior movimentação mesial radicular nos molares superiores no fechamento em massa e maior movimento mesial de coroa dos molares inferiores para o fechamento em duas etapas. Sugere-se que não há diferença na retração dos incisivos superiores e maior retroinclinação dos incisivos inferiores no fechamento de espaços em duas etapas. / Class I malocclusions with dental biprotrusion are characterized by the projection of upper and lower incisors and can be corrected with extractions of four first premolars, allowing incisor retraction using the posterior teeth as anchorage. The purpose of this research was to compare the movement of molars and incisors, by superimpostions of three-dimensional models, with two space closure techniques. Six patients with indication for four first premolar extractions were selected, tomographed (T0) and randomly assigned to two groups. For Group 1 (n=3) premolar extraction space closure was performed in one-stage (en masse retraction) and for group 2 (n=3) in two stages (canine retraction followed by incisor retraction). After complete space closure, a new tomograph was taken (T1). The three-dimensional models, in T0 and T1, for both groups were superimposed to describe and quantify first molar movement. Incisor retraction was evaluated in two dimensions. The upper and lower molars in group 1 presented bodily mesial movement, while those in group 2, presented greater crown than root movement, demonstrating mesial crown tipping. When the amount of mesial molar movement was compared between the two groups, a greater mesial root movement was observed for upper molars in group 1 (p=0.009). However, in both groups the upper molars rotated aroung the palatal root. In the lower arch, a greater mesial crown movement was observed in group 2 (p=0.015). Incisor movement analysis presented similar variations for linear and angular measurements for upper incisors in both groups. In contrast, the angular measurements for the lower incisors demonstrated more torque control in group 2. The treatment time for all patients in the sample was greater than 30 months, with the exception of one patient, who presented treatment time smaller than 24 months. In conclusion, anchorage loss ocurred by bodily movement in en masse space closure and by mesial crown tipping in two-stage space closure, in both arches. In addition, there might be greater mesial root movement for upper molars in en masse space closure and greater mesial crown movement in two-stage space closure. It can also be suggested that there are no differences in upper incisor retraction and there is greater lower incisor uprighting in two-stage space closure.
34

AVALIAÇÃO DO TORQUE DE FRATURA DE MINI-IMPLANTES SUBMETIDOS À ATÉ TRÊS REUTILIZAÇÕES / STUDY OF THE EFFECTS OF STERILIZATION AND REUSE OF MINI-SCREWS, UP TO THREE TIMES, ON TORQUE REQUIRED TO FRACTURE

Miotti, Fabrício Lamberti 29 July 2016 (has links)
Orthodontists have been reusing mini-implants that fail after installation or that will be inserted in a new place due to mechanic needs in order to optimize clinical time. The aim of this study was to simulate the reuse of mini-implants up to three times and evaluate their potential weakness. We used 48 screws (Morelli, Sorocaba, Brazil), which were divided into four groups: C= Control, G1 = one reuse, G2 = two reuse, G3 = three reuse. In order to simulate inserts in patients mouths, we used pig iliac bone. After we insert screws on bone specimen, we removed, cleaned, and sterilized them by autoclaving. The guide at the machine we used allowed us to standardize installations. After all groups were submitted to their reuse periods, mini-implants were submitted to fracture, and the strongest force necessary to break them was measured by a digital axial torquemeter. We used bovine tibia specimens for fracture, because of its greater bone cortical and bone density. We used One Way ANOVA (Bonferroni post-hoc) to compare means of each group. Results showed differences statistically significant between G3 and the other groups. All mini-implants needed strength higher than recommended by the literature to be inserted into patients, even though we found differences in fracture resistance between groups. / Na busca por não perder tempo clínico, ortodontistas vêm reutilizando mini-implantes que falham após a instalação ou que serão instalados em novo local devido à necessidades mecânicas. O objetivo deste estudo foi simular a reutilização de miniimplantes em até três vezes e avaliar a possível fragilização dos mesmos. Para isso, foram utilizados 48 parafusos (Morelli Sorocaba-SP, Brasil), os quais foram divididos em quatro grupos: C = Controle, G1 = uma reutilização, G2 = duas reutilizações e G3 = três reutilizações. Para simular, laboratorialmente, as instalações em boca nos pacientes, foi utilizado osso ilíaco suíno. Após serem inseridos no espécime de osso, os parafusos foram removidos, limpos e esterilizados em autoclave. Com um guia presente na máquina utilizada foi possível padronizar as instalações. Após todos os grupos passarem pelos ciclos de reutilização correspondentes, os mini-implantes foram submetidos à fratura, e a força máxima necessária para a quebra foi medida através de um torquímetro digital axial. Para a fratura, foram utilizados espécimes de tíbia bovina, por possuir maior densidade óssea e espessura de cortical. Os valores médios dos grupos foram analisados pela ANOVA de 1 fator com post-hoc em Bonferroni. Foram encontradas diferenças estatisticamente significativas entre o grupo G3 e os demais grupos. Mesmo com as diferenças na resistência à fratura entre os grupos, todos necessitaram de forças superiores às recomendadas para instalação em pacientes.
35

Minimplante e botão lingual como ancoragem para retração inicial de caninos superiores: estudo prospectivo

Arantes, Flávia de Moraes [UNESP] 29 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:23Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-29Bitstream added on 2014-06-13T21:05:59Z : No. of bitstreams: 1 arantes_fm_dr_araca.pdf: 917045 bytes, checksum: 35b80ca88f794114ea01fe8fe638b23f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A preocupação com a ancoragem é um dos principais fatores a serem considerados no planejamento de um tratamento ortodôntico. Entendem-se como ancoragem os procedimentos intra e extrabucal em que um ou mais dentes ou dispositivos ortodônticos são utilizados como apoio para movimentar outros dentes. A utilização mais frequente dos implantes decorre de uma menor colaboração do paciente, não prejudica a sua estética e ainda cria um sistema de forças mais definido. Por essas razões e pela utilização clínica dos minimplantes de forma indiscriminada, surgiu o interesse em estudar a perda de ancoragem relacionada aos minimplantes. O objetivo deste trabalho foi comparar, por meio de telerradiografias, panorâmicas e modelos, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. Foram selecionados 18 pacientes, divididos em dois grupos aleatórios de 9 indivíduos cada um (A e B), triados para tratamento ortodôntico na Faculdade de Odontologia de Araçatuba – UNESP, Disciplina de Ortodontia. O grupo A utilizou o minimplante enquanto o grupo B utilizou botão lingual. Para todos os pacientes foram realizadas duas telerradiografias (T1 e T2), duas panorâmicas (P1 e P2) e dois modelos (M1 e M2). Os primeiros exames complementares foram realizados ao início (T1, P1 e M1), e o outro, ao final da retração inicial de canino (T2, P2 e M2). Foi eleita a segunda fase (retração inicial de canino), devido à grande perda de ancoragem que se tem neste estágio do tratamento. Todas as medidas foram tabuladas e submetidas a análise estatística. Para comparação entre as fases Início e Após foi utilizado o teste “t” pareado. Para a comparação entre os grupos de minimplante e botão lingual foi utilizado o teste “t” de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Todos os cálculos... / The concern with the anchorage is one of the main factors to be considered when planning an orthodontic treatment. Anchorage comprehends intra and extraoral procedures in which one or more teeth or orthodontic devices are used as a support for moving other teeth. The use more constant of implants is derived from a poor patient collaboration, does not impair the esthetics and still creates more defined forces system. For these reasons and because of the mini-implants clinical utilization in an indiscriminate way, there was an increased interest in studying anchorage loss related to mini-implants. The purpose of this study was to compare, by means of teleradiographies, panoramic radiographs and models, the anchorage loss after initial maxillary canine retraction between two groups. Eighteen patients were selected, then randomly divided into two groups of 9 individuals each (A and B), and elected for orthodontic treatment in the Faculty of Dentistry of Araçatuba – UNESP, Orthodontics Department. Group A utilized mini-implant while group B utilized lingual button. For all patients, two teleradiographies (T1 and T2), two panoramic radiographs (P1 and P2) and two models (M1 and M2) were done. The first complementary exams were accomplished in the beginning (T1, P1 and M1) and the other in the end of the initial canine retraction (T2, P2, and M2). The second phase was elected (initial canine retraction) due to the great anchorage loss that exists in this treatment stage. All measurements were tabulated and submitted to statistical analysis. For the comparison between the stages “Beginning” and “After”, a paired t test was used. For the comparison between the mini-implant and lingual button groups, a Student’s t test for independent measurements was used. In all tests, a significance level of 5% (p<0,05) was adopted. All statistical calculations... (Complete abstract click electronic access below)
36

Influência do diâmetro, comprimento e angulação nos torques de inserção e remoção de mini-implantes autoperfurantes /

Pignatta, Lilian Maria Brisque. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Francisco Antonio Bertoz / Banca: Marcos Rogério de Mendonça / Banca: Paulo Henrique dos Santos / Banca: Maurício Tatsuei Sakima / Banca: Júlio de Araújo Gurgel / Resumo: Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações / Abstract: Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles / Doutor
37

Avaliação da efetividade do laser terapêutico no controle de índice de dor de pacientes em tratamento ortodôntico

Martins, Isabela Parsekian [UNESP] 15 September 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-09-15Bitstream added on 2014-06-13T19:15:33Z : No. of bitstreams: 1 martins_ip_me_arafo.pdf: 359151 bytes, checksum: 80f28aedb7d3c2c8701cee1f7592cef1 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar a aplicação do laser diodo AsGaAl no controle da sensação dolorosa de paciente em procedimento de separação dental dos 1os molares inferiores. Participaram da pesquisa 62 pacientes com idade média de 19,7 anos que iniciaram o tratamento ortodôntico na Clínica de Pós-Graduação da Disciplina de Ortodontia do Departamento de Clínica Infantil da Faculdade de Odontologia de Araraquara - UNESP. Os pacientes foram divididos em 4 grupos alternando a aplicação do laser com e sem efeito terapêutico e de acordo com rodízio do lado do início de sua aplicação: GrupoI- Início laser lado direito; Grupo II- Início placebo lado direito; Grupo III- Início laser lado esquerdo Grupo IV -Início placebo lado esquerdo. O laser, com ou sem efeito terapêutico, foi aplicado antes da separação, 24 e 48 horas após a separação. A dor foi avaliada por uma escala visual analógica. O índice de dor foi registrado antes e após a aplicação do laser com ou sem efeito terapêutico dependendo do grupo, e imediatamente após a separação. Após 24 e 48 horas, o registro da dor se deu antes e após as aplicações de laser com ou sem efeito terapêutico dependendo do grupo. Antes e após a irradiação, a média dos escores da EVA para o grupo placebo e laser foi de zero. Logo após a separação, a média da EVA para o grupo placebo foi de 1,6, significantemente maior que a média de 1,1 registrada para o grupo laser 17 (p=0,013). Após 24 horas e antes da nova irradiação, os valores de dor registrados entre os grupos não se mostraram diferentes, com valores de 2,6 e 2,2 para os grupos placebo e laser, respectivamente. Após a irradiação, os valores caíram para 1,8 e 1,6 não se mostrando diferentes. Após 48 horas, os valores... / The objective of this research was to compare the effect single low-level laser therapy (LLLT) irradiation on pain perception in patients having fixed appliance treatment in the clinic of postgraduate discipline Orthodontics Department, Araraquara-UNESP. Sixty-two patients with mean age, 19.7 years, were recruited to participate in this randomized, double-blinded, placebo-controlled study. The pacients were assigned to 4 groups: Group I- Laser on the right side; Group II- Placebo on the right side; Group III- Laser on the left side; Group IV- Placebo on the left. The laser or placebo was applied before separation, 24 and 48 hours after separation of their first permanent molars in the lower arch. The pain was recorded by a visual analog scale. The data of the pain’s scale was recorded before and after the laser’s or placebo’s irradiation depending on the group, and immediately after separation and then after 24 and 48 hours. Before and after irradiation, the average of the scores of EVA to the placebo group and laser was zero. Just after the separation, the average of the EVA for the placebo group was 1.6, significantly greater than the average of 1.1 registered for the laser Group (p = 0.013). After 24 hours and before the new irradiation, the values registered among the different groups did not show any diferences, with values from 2.2 to 2.6 and placebo groups and laser, respectively. After irradiation, the values dropped to 1.8 and 1.6 not showing 19 differences. After 48 hours, the values continued dropping without any differences. In relation to the gender, only after the first irradiation in placebo group, the female had a level of pain (0.1) significantly higher (p = 0.04) compared to male, and after 48 hours, the group where the laser was applied had a difference (p = 0.04) among the gender with a value of lower pain... (Complete abstract click electronic access below)
38

Estudo comparativo da retenção das bandas ortodônticas Grip Tite, convencional e convencional com a superfície interna microjateada por óxido de alumínio

Vargas, Deborah Bayer Ferraz [UNESP] January 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007Bitstream added on 2014-06-13T18:56:43Z : No. of bitstreams: 1 vargas_dbf_me_arafo.pdf: 680704 bytes, checksum: b86da5b28576f3b91eb2292fc618c8b8 (MD5) / Universidade Estadual Paulista (UNESP) / O objetivo do presente trabalho foi avaliar in vitro, por meio de um ensaio mecânico, a força necessária para a remoção das bandas ortodônticas Grip Tite (C), Convencional (A) e banda Convencional com a superfície interna microjateada por óxido de alumínio (B). Também analisar visualmente a quantidade de cimento residual, e classificar usando uma escala de incrementos a 25%. Após, verificar, por meio de MEV, a superfície com melhores características para a retenção. Os resultados obtidos mostraram que a média de carga do Grupo B, bandas microjateadas internamente por óxido de alumínio, foi significantemente maior que as médias dos Grupos A, bandas Convencionais, e C, bandas Grip Tite. Quanto a quantidade de cimento remanescente nas bandas, o Grupo B apresentou 100% das bandas com índice 4, indicando a presença de mais de 75% de cimento residual nas bandas, enquanto que nos Grupos A e C, houve a predominância do índice 1, indicativo de menos de 25% de cimento residual nas bandas, sem diferença significativa entre esses dois grupos. Os resultados foram confirmados pela MEV, onde observou-se uma superfície com melhores características para a retenção do cimento nas bandas onde foi realizado o processo de microjateamento. Conclui-se que o processo de microjateamento por óxido de alumínio, na superfície interna das bandas convencionais, aumenta a força necessária para a remoção das bandas e aumenta a quantidade de cimento residual preso à superfície da banda. Quando analisada pela MEV, essa superfície apresenta-se como a mais áspera e rugosa, com a maior quantidade de cimento de ionômero de vidro aderido à banda. / The purpose of this study was to evaluate in vitro, the necessary force for the removal of Grip Tite, Conventional and Sandblasted orthodontics molar bands, as well as, to analyze and to classify the amount of residual cement in the internal surface of these bands. After that, checking through scanning electron microscopy, the surface with better characteristics for the retention. The obtained results showed that the load average of the group B, Sandblasted bands, was significantly higher than the group A, Conventional bands, and C, Grip Tite bands. Observing the amount of remaining cement in the bands, group B presented 100% of the bands with index 4, indicating the presence of more than 75% of residual cement in the bands, while in the groups A and C, had the predominance of index 1, indicative of less than 25% of residual cement in the bands, without significant difference between these two groups. The results were confirmed by the scanning electronic microscopy, where the surface with better characteristics for the retention of the cement was observed, in the bands where the sandblasted process was carried through. It was concluded that the process of sandblasted, in the internal surface of the conventional bands, increases the necessary force for the removal of the bands and increases the amount of residual cement in the internal surface of the band. When analyzed by the scanning electronic microscopy, this surface appeared rougher and corrugated, with great amount of glass ionomer cement adhered to the band.
39

Avaliação da resistência ao arrancamento de mini-implantes ortodônticos: estudo laboratorial

Gouvêa, Carla Corrêa Mendes [UNESP] 07 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-07Bitstream added on 2014-06-13T20:17:27Z : No. of bitstreams: 1 gouvea_ccm_me_araca.pdf: 929518 bytes, checksum: 1d39d7891d1bd1d3169ca5b03ea750f2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação para o Desenvolvimento da UNESP (FUNDUNESP) / Sin Implantes / Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal – EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine – EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability
40

Avaliação da resistência ao arrancamento de mini-implantes ortodônticos : estudo laboratorial /

Gouvêa, Carla Corrêa Mendes. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Paulo Henrique dos Santos / Banca: Francisco Antonio Bertoz / Banca: José Fernando Castanha Henriques / Resumo: Objetivo: comparar, por meio do teste de arrancamento, a estabilidade primária de mini-implantes com diâmetro e comprimento diferentes inseridos em osso artificial. Material e método: foram utilizados 80 mini-implantes da marca SIN (Sistema de Implante) com 1mm de perfil transmucoso e divididos em 4 grupos: grupo I - mini-implantes de 1,4 mm de diâmetro e 6 mm de comprimento ; o grupo II - mini-implantes de 1,4 mm de diâmetro e 8 mm de comprimento; o grupo III - mini-implantes de 1,6 mm de diâmetro e 6 mm de comprimento; grupo IV - mini-implantes de 1,6 mm de diâmetro e 8 mm de comprimento. Os mini-implantes foram inseridos em bloco de osso artificial Sawbones (SAWBONES Pacific Research Laboratories) e submetidos ao teste de arrancamento na máquina de ensaio universal - EMIC. Resultados: os valores médios de força de arrancamento dos mini-implantes oscilaram entre 621.995N a 738.220N. A Análise de Variância mostrou que houve diferença estatisticamente significante entre os grupos (p<0.05). Na comparação entre os grupos houve igualdade entre os grupos I e III. Todas as demais comparações foram estatisticamente diferentes. Conclusões: em relação à estabilidade primária, constatou-se que os grupos I e III foram iguais, enquanto que, todos os demais apresentaram diferença na estabilidade / Abstract: Objective: to compare, by means of the pullout test, the primary stability of mini-implants with different diameter and length placed in artificial bone. Method: 80 mini-implants Sin (Implant System) with 1mm transmucosal profile and divided into four groups: Group I - mini-implants with diameter of 1.4mm and 6 mm of long; Group II - mini-implants with diameter of 1.4mm and 8 mm long; Group III - mini-implants with diameter of 1.6mm and 6 mm of long; Group IV - mini-implants with a diameter of 1.6mm and 8 mm of long. Mini-implants were inserted in block artificial bone Sawbones (Sawbones Pacific Research Laboratories) and tested in pullout universal testing machine - EMIC. Results: the mean pullout strength of mini-implants ranged from 621.995 to 738,220 N. Analysis of Variance showed that there was a statistically significant difference between the groups (p <0.05). Comparing the groups were only equality between groups I (mini-implants 1.4 Ø x 6 mm) and III (mini-implants Ø 1.6 x 6mm). All other comparisons are statistically different. Conclusions: relative primary stability, it was found that the groups I and III were similar, whereas all others show differences in stability / Mestre

Page generated in 0.0376 seconds