• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 215
  • 15
  • 15
  • 15
  • 15
  • 13
  • 13
  • 10
  • 7
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 219
  • 118
  • 101
  • 93
  • 62
  • 62
  • 58
  • 58
  • 43
  • 37
  • 37
  • 37
  • 31
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise das angulações mésio-distais de bráquetes pré-ajustados /

Verri, Ana Caroline Gonçales. January 2012 (has links)
Orientador: Marcos Rogério de Mendonça / Banca: Osmar Aparecido Cuoghi / Banca: Arnaldo Pinzan / Resumo: Objetivo: O objetivo do presente estudo foi comparar as angulações dos bráquetes metálicos pré-ajustados da prescrição Roth de incisivos centrais e caninos superiores esquerdos. Materiais e Método: Para o estudo foram selecionados 10 bráquetes, de três marcas disponíveis no mercado: GAC, Forestadent e Morelli. Foram confeccionadas duas matrizes para permitir o posicionamento padronizado dos dentes e bráquetes. A captura das imagens foi realizada a partir de fotografia orto-radial padronizada, por meio de máquina fotográfica digital, exportadas e mensuradas com o programa Image J. Resultados: Os resultados foram submetidos à análise estatística por meio da Análise de Variância (ANOVA), seguido pelo teste Tukey ao nível de significância de 5%. Os bráquetes dos incisivos centrais superiores esquerdos mostraram diferenças estatisticamente significantes entre os seguintes grupos: MOR1 em relação ao GAC1; e FOR1 em relação ao GAC1. Nos caninos superiores esquerdos as diferenças estatisticamente significantes foram entre os grupos: MOR3 em relação ao GAC3; e MOR3 em relação ao FOR3. Conclusão: Com base nos resultados pode-se concluir que, a despeito da mesma denominação para a prescrição, entre marcas diferentes, as angulações não são iguais / Abstract: Objective: The aim of this study was to compare the slot angulations of the pre-adjusted Roth prescription metallic brackets of left central maxillary incisors and left maxillary canines. Materials and Method: Ten brackets of three commercial brands were selected for this study: GAC, Forestadent and Morelli. Two individual metal matrix for brackets and tooth positioning were made for each teeth group. The captured images were made from standardized photography ortho-radial through digital camera, exported and measured with the software Image J. Results: One-way ANOVA and Tukey statistical analysis at 5% of significance level were performed. The results showed statistically significant differences between the brackets of the left maxillary central incisors between MOR1 and GAC1 groups, and between FOR1 and GAC1 groups. The data of left maxillary canines were statistically significant between MOR3 and GAC3 groups, and between MOR3 and FOR3. Conclusion: At basis of these results, it was possible conclude that despite the same prescription name of different brands, the angulations are different / Mestre
12

Resistencia ao cisalhamento de braquetes fixados com resinas polimerizadas por diferentes tipos de ativação

Guedes-Pinto, Eduardo 27 November 1997 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T01:37:33Z (GMT). No. of bitstreams: 1 Guedes-Pinto_Eduardo_M.pdf: 2855830 bytes, checksum: ffca1786148a3514f02f16d72b6577e2 (MD5) Previous issue date: 1997 / Resumo: A proposta deste estudo foi avaliar a resistência ao cisalhamento de três materiais de colagem, polimerizados por diferentes sistemas de ativação. Foram utilizados 60 pré-molares humanos, extraídos com finalidade de tratamento ortodôntico. As faces vestibulares foram condicionadas com ácido fosfórico a 37% durante 30 segundos e os bráquetes fixados ao esmalte dentário com as . resinas Concise Ortodôntico (3M), Z-100 (3M) e cimento resinoso Dual (3M). Após a fixação dos bráquetes metálicos, os corpos-de-prova foram submetidos ao teste de cisalhamento 10 minutos e 24 horas após as colagens. Os resultados submetidos à análise estatística mostraram que houve diferença estatisticamente significante entre os três tipos de resina para os dois períodos de tempo de armazenamento. O sistema de colagem mais resistente foi promovido pelo Concise Ortodôntico, seguido pela resina fotoativada Z-100, e o menos resistente foi o cimento resinoso Dual. O tempo de armazenamento foi estatisticamente significante, pois representou aumento na resistência ao cisalhamento nos três tipos de materiais, provavelmente, devido à contínua conversão dos radicais livres / Abstract: The purpose of this study was to evaluate the shear bond strengths of three bonding materiaIs, activated by different systems. Sixty human premolars, extracted for orthodontic reasons, were used. Vestibular faces were etched for 30 seconds with 37% phosphoric acid gel and brackets were bonded to enamel surface using Concise chemically cured adhesive (3M), Z-100 light-cured adhesive (3M) and Dual cemerit resin (3M). After the bonding of metal brackets, specimens were tested and the shear stress at bond failure was recorded at 10 minutes and 24 hours. Results submitted to statistical analysis demonstrated a statistically significant difference in shear bond strengths among the three resins for both periods of storage. The most resistant bonding system was the Concise group, followed by the light-cured Z-100 and the less resistant Dual cement resin. The storage was statistically significant by increasing the shear bond strengths of the three materiaIs, probably because of the continue conversion / Mestrado / Ortodontia / Mestre em Ciências
13

Determinação da rugosidade, força de deslizamento, coeficiente e resistencia de atrito entre braquetes e fios ortodonticos

Secco, Angelo Stefano 25 July 2018 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T18:54:50Z (GMT). No. of bitstreams: 1 Secco_AngeloStefano_D.pdf: 5008331 bytes, checksum: edd9d70da37852140146362ca5b4758a (MD5) Previous issue date: 1999 / Resumo: Considerando a falta de informações a respeito da força de deslizamento e 1 de atrito quando utiliza-se a mecânica de deslize com materiais de fabricação nacional, este trabalho foi desenvolvido com o objetivo de determinar a magnitude da força necessária para que ocorra o deslizamento do bráquete no fio, assim como determinar o valor da força de atrito, o percentual da força despendida com o atrito, o efeito da espessura dos fios na força de atrito, o coeficiente de atrito entre bráquetes e os fios, além de comparar a rugosidade do fio nacional com a do fio importado. Foi utilizado um sistema que simula a situação na qual os dentes inclinam suavemente até criar pontos de contato duplos e opostos entre a canaleta dos bráquetes e o fio. O sistema gerou uma tensão de 100g no centro de resistência a 10 mm da canaleta do bráquete, agindo no sentido oposto ao da força aplicada para mover o dente. Foram avaliadas 3 marcas de fios e bráquetes: duas nacionais - Tecnident e Morelli e uma importada - Dentaurum, Alemanha. Foram utilizados bráquetes metálicos de canaleta 0,022" e três : espessuras de fios 0,016x 0,022", 0,018x0,025" e o 0,021x0,025". Os testes foram realizados em uma máquina de ensaios Instron a uma velocidade de : 5mm/min. Os resultados apresentaram as seguintes médias de força de deslizamento para os fios Tecnident (198g) e Morefli (199g); estes resultados foram maiores e diferiram ao nível de significância de 5% da força requerida para deslizar o bráquete no fio importado Dentaurum, (178g). A variação da espessura dos arcos não interferiu significativamente na força de deslizamento assim como na força de atrito. A força de atrito desenvolvida pelos materiais nacionais Tecnident (98g) e Morelli (99g) foi maior e diferiu ao nível de significância de 5% da desenvolvida para o importado Dentaurum (78g). O percentual médio de força dissipada pelo atrito entre o bráquete e o fio ortodôntico durante o deslizamento foi de aproximadamente 49,8% para o conjunto bráquetes/arcos nacionais e 44,0% para o importado. Essa diferença foi significativa ao nível de 5% de significância. O material da marca Tecnident apresentou o maior coeficiente de atrito (0,164534); no entanto, a Morelli (0,150190) não diferiu estatisticamente da Dentaurum, que apresentou o menor coeficiente de atrito (0,147943). A rugosidade média dos fios da Tecnident foi da ordem de 0,15 um, aproximadamente 50% mais rugosos que os valores encontrados para os fios da marca Morelli 0,07u.m e da Dentaurum 0,07 j,m . Os fabricantes nacionais de bráquetes e fios ortodônticos devem rever o processo da fabricação de seus produtos para melhorar suas propriedades e características / Abstract: An appliance was constructed to simulate tooth movement in a previously aligned arch relative to bracket slot Nevertheless, when tooth was translated to siding mechanics, the crown was moved before the root, resulting in bracket tapping and angulation relative to the arch wire, making the arch contact the bracket two opposite points, creating friction. Regarding the lack of information about this situation using national manufactured materials, we developed the present study in order to determine: the force magnitude to occur bracket sliding, the frictional force \falues, the percentage of force dispersed by the friction, the effect of archwire \j/idth in frictional force, the coefficient of friction between brackets/archwires; and p compare the national and international archwires roughness. The system used simulated the clinical situation which slightly teeth tipping created two opposite joints contact between bracket slot and archwire. The system created a tension of 100g in the center of resistance from 10 mm to the bracket slot, acting in opposite side of the applied force to move the tooth. Three different arches and brackets ijjnds were evaluated, two national (Tecnident and Morelli) and one international (JDentaurum, from Germany). Stainless steel brackets slot of 0.022" and three archwires width were used (0.016 x 0.022", 0.018 x 0.025" and 0.021 x 0.025"). The tests were realized with an Instron testing machine moving at a speed of 5 ijnm/min. Results showed that mean force required to conduct brackets along national arches - Tecnident (198g) and Morelli (199g) - were higher and had Significant difference at 5% level to international one - Dentaurum (178g). The change in arches width did not interfere significantly both in sliding and frictional force. Frictional force developed by national materials Tecnident (98g) and Morelli (99g), were higher than international Dentaurum (78g), which was different statistically at 5% level. The mean force dispersed by friction between bracket and archwire during sliding was 49,8% to the national bracket/arch combination approximately, and 44% to the international one. This difference was significant at 5% level. National material Tecnident presented the highest frictional coefficient (0.164534). National material Morelli (0.150190) was not significant statistically relative to Dentaurum (0.1479430), which showed the lowest frictional coefficient. The average roughness of Tecnident arch was 0.15 urn approximately 50% more roughness than values found to Morelli (0.7 urn) and Dentaurum (0.7 jj.m) arches, in which there were not significant differences statistically (p<0.05) between roughness values / Doutorado / Doutor em Materiais Dentários
14

Estudo das alterações sagitais, verticais e transversais decorrentes da distalização dos molares superiores com o aparelho Pendulum

Fuziy, Acácio 30 May 2001 (has links)
Nessa pesquisa, foram estudados 32 pacientes, 23 do sexo feminino e 9 do masculino, leucodermas, brasileiros, naturais da cidade de Bauru, estado de São Paulo, com idade variando de 11 anos e 6 meses a 17 anos e 9 meses, idade média de 14 anos e 7 meses, portadores de más oclusões de Classe II, 1ª divisão de Angle e presença de todos os dentes permanentes de segundo a segundo molar do lado oposto. Todos os indivíduos selecionados receberam como mecanismo para a distalização dos molares superiores, o aparelho Pendulum de Hilgers, que foi empregado por um período de 5,87 meses. Foram feitas as telerradiografias em norma lateral convencional, lateral de 45º e modelos de estudo, antes e depois das distalizações dos molares superiores. Foram obtidas as medidas cefalométricas e as medidas dos modelos de estudo e as diferenças entre as médias iniciais e finais do experimentos foram submetidas ao teste estatístico de Wilcoxon para dados pareados. Essa avaliação possibilitou verificar as alterações esqueléticas e os efeitos da distalização sobre os molares, pré-molares, caninos e incisivos superiores. Com base nos resultados obtidos e na metodologia empregada, no que tange as alterações esqueléticas e dentárias decorrentes da distalização de primeiros e segundos molares superiores com o aparelho Pendulum, julga-se lícito concluir que a força leve e contínua das molas distalizadoras do aparelho e o intervalo de tempo não alteraram significativamente o posicionamento ânteroposterior da maxila e mandíbula. Observou-se uma taxa de distalização mensal dos molares de 1,06 mm e 1,07 mm, respectivamente para os lados direito e esquerdo. Essa distalização foi acompanhada da inclinação distal das coroas dos molares que acarretou a rotação mandibular no sentido horário, refletindo diretamente no aumento da altura facial ântero-inferior. O efeito recíproco do aparelho Pendulum sobre a unidade de ancoragem acarretou o movimento mesial dos primeiros e segundos pré-molares e dos caninos. Outro efeito negativo constatado foi o movimento vestibular dos incisivos superiores e a sua conseqüência para a alteração no perfil facial. Associado a distalização dos molares superiores foi observado também alterações verticais e transversais em molares, pré-molares e caninos. / In this study, 32 patients were studied. 23 females and 9 males, leucoderma, Brazilian, natural from Bauru, São Paulo state, with ages ranging from 11,06 years to 17,09 years, mean age 14,07 years, all carriers of Angle Class II division 1 malocclusions and presence of all permanent teeth from second molar to second molar in the same arch. To all the selected individuals were given for distalization of upper molars, the HILGERS Pendulum appliance which was used for a period of 5,87 months. Lateral cephalometric radiographs, 45º lateral cephalometric radiographs and dental casts were made before and after the upper molars distalizations. The cephalometric and the dental casts measurements were obtained and the differences between the initial and final measurements were submmited to the Wilcoxon statistical test for paired data. This evaluation possibilitated to verify the skeletal alterations and the effects of distalization on upper molars and premolars, canines and incisives. On the basis of the obtained results and on the employed methodology concerning the skeletal and dental alterations caused by the distalization of upper first and second molars with the Pendulum appliance it can be concluded that the light and continued force of the distalization springs and the time spent did not alter significantly the maxila and mandible anteroposterior positioning. A monthly distalization rate of 1,06 mm and 1,07mm was observed, respectively for right and left sides. This distalization was followed by the distal inclination of the molar crown which caused a mandibular rotation in a clockwise direction, reflecting directly on the increase of the anteroinferior facial height. The reciprocal effect of Pendulum appliance over the anchorage unit caused the first and second premolars and canines mesial movement. Another negative effect proved was the vestibular movement of the upper incisives and its consequence on the facial profile alteration. Associated to the upper molar distalization it was also observed the vertical and transverse alterations in molars, premolars and canines.
15

Estudo das alterações sagitais, verticais e transversais decorrentes da distalização dos molares superiores com o aparelho Pendulum

Acácio Fuziy 30 May 2001 (has links)
Nessa pesquisa, foram estudados 32 pacientes, 23 do sexo feminino e 9 do masculino, leucodermas, brasileiros, naturais da cidade de Bauru, estado de São Paulo, com idade variando de 11 anos e 6 meses a 17 anos e 9 meses, idade média de 14 anos e 7 meses, portadores de más oclusões de Classe II, 1ª divisão de Angle e presença de todos os dentes permanentes de segundo a segundo molar do lado oposto. Todos os indivíduos selecionados receberam como mecanismo para a distalização dos molares superiores, o aparelho Pendulum de Hilgers, que foi empregado por um período de 5,87 meses. Foram feitas as telerradiografias em norma lateral convencional, lateral de 45º e modelos de estudo, antes e depois das distalizações dos molares superiores. Foram obtidas as medidas cefalométricas e as medidas dos modelos de estudo e as diferenças entre as médias iniciais e finais do experimentos foram submetidas ao teste estatístico de Wilcoxon para dados pareados. Essa avaliação possibilitou verificar as alterações esqueléticas e os efeitos da distalização sobre os molares, pré-molares, caninos e incisivos superiores. Com base nos resultados obtidos e na metodologia empregada, no que tange as alterações esqueléticas e dentárias decorrentes da distalização de primeiros e segundos molares superiores com o aparelho Pendulum, julga-se lícito concluir que a força leve e contínua das molas distalizadoras do aparelho e o intervalo de tempo não alteraram significativamente o posicionamento ânteroposterior da maxila e mandíbula. Observou-se uma taxa de distalização mensal dos molares de 1,06 mm e 1,07 mm, respectivamente para os lados direito e esquerdo. Essa distalização foi acompanhada da inclinação distal das coroas dos molares que acarretou a rotação mandibular no sentido horário, refletindo diretamente no aumento da altura facial ântero-inferior. O efeito recíproco do aparelho Pendulum sobre a unidade de ancoragem acarretou o movimento mesial dos primeiros e segundos pré-molares e dos caninos. Outro efeito negativo constatado foi o movimento vestibular dos incisivos superiores e a sua conseqüência para a alteração no perfil facial. Associado a distalização dos molares superiores foi observado também alterações verticais e transversais em molares, pré-molares e caninos. / In this study, 32 patients were studied. 23 females and 9 males, leucoderma, Brazilian, natural from Bauru, São Paulo state, with ages ranging from 11,06 years to 17,09 years, mean age 14,07 years, all carriers of Angle Class II division 1 malocclusions and presence of all permanent teeth from second molar to second molar in the same arch. To all the selected individuals were given for distalization of upper molars, the HILGERS Pendulum appliance which was used for a period of 5,87 months. Lateral cephalometric radiographs, 45º lateral cephalometric radiographs and dental casts were made before and after the upper molars distalizations. The cephalometric and the dental casts measurements were obtained and the differences between the initial and final measurements were submmited to the Wilcoxon statistical test for paired data. This evaluation possibilitated to verify the skeletal alterations and the effects of distalization on upper molars and premolars, canines and incisives. On the basis of the obtained results and on the employed methodology concerning the skeletal and dental alterations caused by the distalization of upper first and second molars with the Pendulum appliance it can be concluded that the light and continued force of the distalization springs and the time spent did not alter significantly the maxila and mandible anteroposterior positioning. A monthly distalization rate of 1,06 mm and 1,07mm was observed, respectively for right and left sides. This distalization was followed by the distal inclination of the molar crown which caused a mandibular rotation in a clockwise direction, reflecting directly on the increase of the anteroinferior facial height. The reciprocal effect of Pendulum appliance over the anchorage unit caused the first and second premolars and canines mesial movement. Another negative effect proved was the vestibular movement of the upper incisives and its consequence on the facial profile alteration. Associated to the upper molar distalization it was also observed the vertical and transverse alterations in molars, premolars and canines.
16

Avaliação do esmalte dentário antes e após a colagem e descolagem de braquetes ortodônticos / Evaluation of dental enamel before and after fixing and removal of orthodontic brackets ortodônticos

Santos Junior, Jose Hermenergildo dos 13 March 2009 (has links)
O objetivo deste trabalho foi avaliar a quantidade de resina residual após a descolagem de braquetes e a perda e/ou desgaste de esmalte ocorrido durante as fases de: colagem, descolagem e remoção dos remanescentes resinosos, na área do braquete e adjacente. A amostra foi constituída de 150 pré-molares, dividida em dois grupos de acordo com o tipo de material do braquete utilizado: metálico (n=75) e cerâmico (n=75), nas duas primeiras fases do estudo, colagem e descolagem. Os procedimentos de colagem foram realizados de acordo com a International Organization for Standardization (2003), e a descolagem segundo a orientação preconizada pelo fabricante. Na fase de remoção dos remanescentes resinosos foram considerados cinco grupos de acordo com o protocolo de acabamento/polimento e prescrição dos respectivos fabricantes: FF diamantada + Soflex; Pedra Shofu; Dentaurum Carbide; Komet Carbide e Jet Carbide, com auxilio de lupas telescópicas sob a magnificação 3x. A avaliação qualitativa (ARIm e ESI) foi realizada por meio de fotografias digitais (lupa estereoscópica - Olympus SZ61). A avalição quantitativa foi realizada pelo método de medição por Coordenada - Coordinate Measuring Machines (Mitutoyo), mod. Legex CNC 9106 - Perfil de linha. As possíveis diferenças entre os protocolos de acabamento/polimento foram avaliadas pela análise de variância (ANOVA) e pelo teste de comparações múltiplas de Tukey. As quantidades médias de resina residual encontrada na área sob a base do braquete, após acabamento/polimento foram: Diamantada FF + Soflex (10,4 m ±10,5), Pedra Shofu (18,5 m ± 12,1), Dentaurum Carbide (11,2 m ± 11,9), Komet Carbide (9,5 m ± 10,8) e Jet Carbide (22,8 m ± 24,0). E na área adjacente: Diamantada FF + Soflex (14,9 m ± 13,0), Pedra Shofu (22,8 m ±19,5), Dentaurum Carbide (21,4 m ±18,5), Komet Carbide (9,6 m ± 7,7), Jet Carbide (27,8 m ± 24,5). Desta forma, constatou-se que, em geral, os protocolos de acabamento/polimento deixaram maior quantidade de resina residual sobre a área adjacente que na área do braquete, com exceção do protocolo Komet Carbide, que teve desempenho semelhante em ambas as áreas. E as quantidades médias de perda e/ou desgaste do esmalte na área do braquete foram: Diamantada FF + Soflex (-134,9 m ± 56,4), Pedra Shofu ( 39,2 m ± 12,8), Dentaurum Carbide ( 70,5 m ± 27,9), Komet Carbide (-44,8 m ± 14,3) e Jet Carbide ( 68,2 m ± 35,7) na área do braquete, enquanto na área adjacente: Diamantada FF + Soflex (-124,7 m ± 133,1), Pedra Shofu (- 37,9 m ± 25,1), Dentaurum Carbide (- 60,1 m ±32,4), Komet Carbide (-36,6 m ± 19,5) e (Jet Carbide 65,4 m ± 65,0) (Tabela 5.9). Ressalta-se que em ambas as áreas de avaliação, o protocolo (Diamantada FF + Soflex) foi responsável pela maior quantidade de perda e/ou desgaste, diferenciando-se com significância estatística dos demais protocolos. Com base nestes resultados podemos concluir que os protocolos de acabamento/polimento avaliados demonstraram excelente desempenho na remoção dos remanescentes resinosos embora nenhum deles tenha sido capaz de remover totalmente o material de colagem, todos danificaram o esmalte, sendo o protocolo Komet carbide o mais diferenciado. / The objective of this study was to evaluate the quantity of residual resin after removal of brackets and the loss and//or wear-and-tear of enamel occurring during the phases of fixing, detaching and removal of remnant resin in the bracket area and its adjacent. The sample was made up of 150 premolars, divided into two groups in accordance with the type of bracket material used: metal (n=75) and ceramic (n=75), in the two initial phases of study, fixing and removal. Fixing procedures were carried out in accordance with the International Organization for Standardization, (2003), and removal according to orientation advocated by the manufacturer. In the removal of remnant resin phase five groups were considered, all in agreement with the finishing/polishing protocol and prescription of the respective manufacturers: FF diamantada + Soflex; Pedra Shofu; Dentaurum Carbide; Komet Carbide and Jet Carbide, and with the aid of telescopic magnifying glass of three-fold magnification Qualitative evaluation (ARIm and ESI) was done by means of digital photographs(stereoscopic magnifying glass Olympus SZ61). Quantitative evaluation was conducted using the coordinate medication method - Coordinate Measuring Machines (Mitutoyo), mod. Legex CNC 9106 - line profile. Possible differences between finishing/polishing protocols were evaluated via variance analysis (ANOVA), and by Tukey Multiple Comparison test. Median quantities of residual resin found in the region below the base of the bracket, following finishing/polishing were: Diamantada FF + Soflex (10,4 m ±10,5), Pedra Shofu (18,5m ± 12,1), Dentaurum Carbide (11,2 m ± 11,9), Komet Carbide (9,5 m ± 10,8) and Jet Carbide (22,8 m ± 24,0). In this way, it was confirmed that finishing/polishing protocols, in general, left the major part of residual resin below the adjacent area than in the bracket area, with the exception of Komet Carbide protocol, displaying similar performance in both areas Median quantities of loss and/or wearand- tear of enamel in the bracket area were: Diamantada FF + Soflex (-134,9 m ± 56,4), Pedra Shofu ( 39,2 m ± 12,8), Dentaurum Carbide ( 70,5 m ± 27,9), Komet Carbide (-44,8 m ± 14,3) and Jet Carbide ( 68,2 m ± 35,7) in bracket area, while in adjacent area: Diamantada FF + Soflex (-124,7 m ± 133,1), Pedra Shofu (- 37,9 m ± 25,1), Dentaurum Carbide (- 60,1 m ±32,4), Komet Carbide (-36,6 m ± 19,5) and (Jet Carbide 65,4 m ± 65,0) (Table 5.9) Standing out in both areas of evaluation, protocol (Diamantada FF + Soflex) was responsible for the major quantity of loss and /or wear and tear, differentiating itself from the other protocols by significant statistics. Based on these results, we can conclude that the finishing/polishing protocols evaluated, displayed excellent performance in the removal of remnant resin, although none have totally been capable of removing fixing material, and all damaged the enamel, with Komet protocol being the most differentiated.
17

Análise do comportamento biomecânico de fios ortodônticos após tratamento de superfície

Moreira, Renata Helena da Silva [UNESP] 23 April 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-04-23Bitstream added on 2014-06-13T20:16:11Z : No. of bitstreams: 1 moreira_rhs_me_guara.pdf: 1620956 bytes, checksum: e70dbaf4dfb1c01921ef51fc17d1cb18 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fios ortodônticos são fabricados com uma série de materiais como aço inoxidável, metais, cerâmicas e polímeros. No meio bucal, eles estão sujeitos a fluídos corrosivos e variação de pH podendo levar a liberação de íons níquel nos tecidos e fluídos corpóreos. Neste estudo in vitro, filmes de carbono amorfo hidrogenado A-C:H foram depositados em fios ortodônticos empregando a técnica de PECVD para inibir a liberação de íons. O arranjo estrutural dos fios foi estudado a partir de Espectroscopia Raman e a molhabilidade avaliada medindo-se o ângulo de contato da superfície. Para avaliar a liberação de íons, os arcos ortodônticos (com e sem filme) foram montados em modelos confeccionados com resina e imersos em solução fisiológica a 37°C por 30 dias. Durante o tempo de imersão as amostras foram lavadas e/ou imersas em colutórios diariamente. Espectrofotometria de absorção atômica foi usada para medir a liberação de elementos a partir de amostras. Os resultados mostraram que o revestimento previne a liberação de Ni dos fios. O tratamento de superfície alterou o comportamento mecânico dos fios avaliados / Orthodontics wires are made from a variety of metals such as stainless steel, metals, ceramics and polymers. In oral environment, they are subjected to aggressive fluids and pH variation that can lead to nickel ions releasing to body tissues and fluids. In this in vitro study, A:C-H films were deposited on orthodontics wires by radio-frequency plasma-enhanced chemical vapour deposition (PECVD) from inhibited nickel ions release. The structural arrangement of films was probed by Raman spectroscopy and contact angle measurements were carried out in order to evaluate the wettability of surface. To evaluate ions release, orthodontics wires (coated and uncoated) were mounted in resin mould and immersed inn physiological serum for 30 days at 37°C. During the immersion time the samples were brushed and/or immersed in mouthwashes daily. Atomic absorption spectrophotometry was used to measure the release of elements from the samples in solution. Results showed that the coating prevents Ni release of orthodontics wires. Surface treatment change mechanical properties of orthodontics wires
18

Influência do tratamento de superfície na força friccional de fios ortodônticos de NiTi-estudo in vitro

Seixas, Maurício Rangel [UNESP] 02 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-02Bitstream added on 2014-06-13T18:55:40Z : No. of bitstreams: 1 seixas_mr_me_guara.pdf: 4578548 bytes, checksum: 654971c9dbf6bacfe64f0af3970c20b8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Nos últimos anos, ligas de níquel-titânio têm sido usadas em odontologia devido suas propriedades mecânicas favoráveis e resistência a corrosão. Portanto, no meio ambiente oral, elas são sujeitas a fluidos agressivos e variação de pH podendo levar a liberação de íons de níquel para tecidos e fluidos do corpo. Modificações na superfície destas ligas têm sido realizadas usando tratamentos mecânico, eletroquímico, químico e físico. Carbono amorfo hidrogenado (a-C:H) obtido por técnicas de deposição tem muitas propriedades atrativas tais como alta dureza superficial, inércia química e biocompatibilidade. Desse modo, como a fricção é em função das superfícies dos braquete e fios, o propósito deste trabalho foi avaliar a influência do tratamento de superfície na fricção de fios ortodônticos. Neste estudo in vitro, filmes a-C:H foram depositados em fios ortodônticos de níquel-titânio empregando a técnica PECVD (Deposição Química por Plasma de Rádio frequência). O arranjo estrutural dos filmes de DLC foi avaliado por espectroscopia de Raman e a adesão por ensaio de risco (scratching). As amostras foram divididas em dois grupos, com e sem tratamento de superfície e as forças friccionais foram avaliadas empregando-se um dispositivo confeccionado em laboratório. Os valores obtidos foram comparados usando test t-student. O resultado mostrou que fios de NiTi não tiveram uma diferença estatística significante (P>0,05) na fricção após tratamento de superfície / In the last years, nickel-titanium alloys have been used in dentistry due their excellent mechanical properties and corrosion resistance. However, in oral environment, they are subject aggressive fluids and pH variation can be leave nickel ions release to body tissues and fluids. Surface modifications of these alloys have been realized using mechanical, electrochemical, chemical and physical treatments. Hydrogenated amorphous carbon (a-C:h) prepared by deposition techniques have very attractive properties such as high hardness, chemical inertness and biocompatibility. Thus, as the friction is a function of the surfaces of the wires and brackets is very important to evaluate them after the coating. The purpose of this work was to evaluate the influence of surface treatment in the friction of the orthodontics wires. In this vitro study,a -C:H films were deposited on orthodontics bracket by r.f. plasma-enhanced chemical vapour deposition (PECVD). The structural arrangement of DLC films was probed by Raman spectroscopy and adhesion was eveluated by scratching. Samples were divided in two groups, with and without surface treatment and frictional forces were measured with a custom made jig. The values obtained were compared using student's t-test. The results showed that NiTi wires no had a statistically significant differenc (P.0,05) in friction after surface treatment
19

Influência do tratamento de superfície na força friccional de fios ortodônticos de NiTi-estudo in vitro /

Seixas, Maurício Rangel. January 2011 (has links)
Resumo: Nos últimos anos, ligas de níquel-titânio têm sido usadas em odontologia devido suas propriedades mecânicas favoráveis e resistência a corrosão. Portanto, no meio ambiente oral, elas são sujeitas a fluidos agressivos e variação de pH podendo levar a liberação de íons de níquel para tecidos e fluidos do corpo. Modificações na superfície destas ligas têm sido realizadas usando tratamentos mecânico, eletroquímico, químico e físico. Carbono amorfo hidrogenado (a-C:H) obtido por técnicas de deposição tem muitas propriedades atrativas tais como alta dureza superficial, inércia química e biocompatibilidade. Desse modo, como a fricção é em função das superfícies dos braquete e fios, o propósito deste trabalho foi avaliar a influência do tratamento de superfície na fricção de fios ortodônticos. Neste estudo in vitro, filmes a-C:H foram depositados em fios ortodônticos de níquel-titânio empregando a técnica PECVD (Deposição Química por Plasma de Rádio frequência). O arranjo estrutural dos filmes de DLC foi avaliado por espectroscopia de Raman e a adesão por ensaio de risco (scratching). As amostras foram divididas em dois grupos, com e sem tratamento de superfície e as forças friccionais foram avaliadas empregando-se um dispositivo confeccionado em laboratório. Os valores obtidos foram comparados usando test t-student. O resultado mostrou que fios de NiTi não tiveram uma diferença estatística significante (P>0,05) na fricção após tratamento de superfície / Abstract: In the last years, nickel-titanium alloys have been used in dentistry due their excellent mechanical properties and corrosion resistance. However, in oral environment, they are subject aggressive fluids and pH variation can be leave nickel ions release to body tissues and fluids. Surface modifications of these alloys have been realized using mechanical, electrochemical, chemical and physical treatments. Hydrogenated amorphous carbon (a-C:h) prepared by deposition techniques have very attractive properties such as high hardness, chemical inertness and biocompatibility. Thus, as the friction is a function of the surfaces of the wires and brackets is very important to evaluate them after the coating. The purpose of this work was to evaluate the influence of surface treatment in the friction of the orthodontics wires. In this vitro study,a -C:H films were deposited on orthodontics bracket by r.f. plasma-enhanced chemical vapour deposition (PECVD). The structural arrangement of DLC films was probed by Raman spectroscopy and adhesion was eveluated by scratching. Samples were divided in two groups, with and without surface treatment and frictional forces were measured with a custom made jig. The values obtained were compared using student's t-test. The results showed that NiTi wires no had a statistically significant differenc (P.0,05) in friction after surface treatment / Orientador: Ana Paula Rosifini Alves Claro / Coorientador: Weber José da Silva Ursi / Banca: Cristiane Aparecida de Assis Claro / Banca: Humberto Lopes Rodrigues / Mestre
20

ESTUDO COMPARATIVO DA POSIÇÃO ÂNTERO POSTERIOR DOS PRIMEIROS MOLARES INFERIORES NO TRATAMENTO ORTODÔNTICO, UTILIZANDO AS TÉCNICAS STRAIGHT-WIRE E EDGEWISE, EM CASOS DE MÁ OCLUSÃO DE CLASSE I DE ANGLE, COM EXTRAÇÃO DE PRIMEIROS PRÉ-MOLARES / Comparative study of the anterior-posterior position of the lower first molars in the orthodontic treatment, using Straight-Wire and Edgewise techniques, in cases with Angle Class I malocclusion, with extraction of first premolars

Ferreira, Daniella Prado 09 March 2005 (has links)
Made available in DSpace on 2016-08-03T16:31:09Z (GMT). No. of bitstreams: 1 1Capas.pdf: 35586 bytes, checksum: ff82f4ad75e989cb5da20b6e88f48ee3 (MD5) Previous issue date: 2005-03-09 / This study evaluated the anterior-posterior position of the lower first molars, during the orthodontic treatment, using a lingual arch as an anchorage accessory in the Straight-Wire technique, in comparison to the cases treated by the Edgewise technique, without the use of a lingual arch. Two groups were selected, both presenting with Angle7 Class I malocclusion, treated with the extraction of upper and lower first premolars. The sample consisted of 255 lateral cephalometric x-rays obtained from Brazilian patients. The patients were of both genders, with an average age between 13 years and 6 months and with different standards of facial growth. Based in the analysis and discussion of the results, it was concluded that: 1) from the start of treatment to the end of leveling phase, the lost of anchorage by mesial crown tipping of lower first molar was greater in the cases treated with Straight-Wire technique; 2) from the end of leveling phase to the end of treatment, the lost of anchorage by bodily movement of the lower first molar was greater in the Edgewise technique; 3) from start to end of treatment the total anchorage loss was greater in the patients treated with Edgewise technique; e 4) the anterior-posterior movement of the lower incisors did not shown any statistically significant difference for both techniques, in all phases of treatment.(AU) / Este estudo avaliou o posicionamento ântero posterior dos primeiros molares inferiores, durante o tratamento ortodôntico, utilizando o arco lingual inferior como acessório de ancoragem na técnica Straight-Wire, em comparação aos casos tratados pela técnica Edgewise, sem a utilização do arco lingual. Dois grupos foram selecionados, ambos apresentando má oclusão de Classe I de Angle7, tratados com extração dos primeiros pré-molares superiores e inferiores. Foi utilizada uma amostra de 255 telerradiografias em norma lateral, obtidas de pacientes brasileiros, de ambos os sexos, com média de idade de 13 anos e 6 meses e com diferentes padrões de crescimento facial. Embasado na análise e discussão dos resultados, concluiu-se que: 1) do início do tratamento ao fim da fase de nivelamento, a perda de ancoragem coronária do primeiro molar inferior foi maior nos casos tratados com a técnica Straight-Wire; 2) do fim da fase de nivelamento ao fim do tratamento, a perda de ancoragem coronária e radicular do primeiro molar inferior foi maior na técnica Edgewise; 3) do início ao fim tratamento a perda de ancoragem radicular foi maior nos pacientes tratados com a técnica Edgewise; e 4) o deslocamento ântero-posterior dos incisivos inferiores não apresentou diferença estatisticamente significante para ambas as técnicas, em todas as etapas observadas.(AU)

Page generated in 0.0386 seconds