• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 215
  • 15
  • 15
  • 15
  • 15
  • 13
  • 13
  • 10
  • 7
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 219
  • 118
  • 101
  • 93
  • 62
  • 62
  • 58
  • 58
  • 43
  • 37
  • 37
  • 37
  • 31
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Tratamento de hiperplasia gengival com laser de CO2 : conceitos e tecnica conservadora

Bellini, Bruno Siqueira 03 August 2018 (has links)
Orientador: Ester Maria Danielli Nicola / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T19:34:09Z (GMT). No. of bitstreams: 1 Bellini_BrunoSiqueira_M.pdf: 1442538 bytes, checksum: 74efd2947e289c0bddf4aa0b99742674 (MD5) Previous issue date: 2003 / Resumo: As hiperplasias gengivais representam cerca da metade das lesões proliferativas que acometem a cavidade bucal. Os profissionais de saúde, em contato com pacientes apresentando estas alterações gengivais, devem investigá-los criteriosamente, até que sejam determinadas as etiologias destas ou de quaisquer desalinhamentos dentários a estes relacionados. A propedêutica clínica revelará a capacidade do indivíduo em lidar com as alterações locais e ou sistêmicas atuantes e fornecerá subsídios para o prognóstico e plano de tratamento. Nessa investigação, a abordagem clínica foi executada por uma equipe multidisciplinar, envolvendo médicos, enfermeiros e odontólogos, numa casuística de 18 pacientes portadores de hiperplasias gengivais, triados nos ambulatórios de odontologia buco-maxilo-facial e otorrinolaringologia do Hospital de Clínicas da Universidade Estadual de Campinas (Unicamp). A biópsia incisional prévia no tecido gengival hiperplásico foi realizada, como condição pré-operatória. Exames clínico-laboratoriais pré-operatórios foram solicitados de acordo com a necessidade individual específica de cada paciente. Depois de estabelecidos individualmente os diagnósticos e prognósticos da patologia de base, foram elaborados planos de tratamento bucal nos sítios eleitos. Procedimentos cirúrgicos ambulatoriais com laser de CO2 10,6µm foram executados sob anestesia local, com o objetivo de favorecer o restabelecimento e controle das funções fisiológicas normais do sistema estomatognático, fonoarticulatório e respiratório, através de gengivoplastias e orientações quanto à importância da higienização bucal e manutenção da saúde destes sistemas. A potência do laser utilizada nessas aplicações foi determinada de acordo com a necessidade de cada caso, dependendo da natureza, localização e extensão dos aumentos gengivais. O número de aplicações de laser de CO2, necessárias para a finalização do tratamento, também seguiu estes mesmos critérios. As avaliações clínicas, radiográficas e fotográficas foram realizadas antes de cada sessão de aplicação de laser de CO2, estabelecendo, assim, padrões comparativos posteriores. Os pacientes tratados eram usuários de medicamentos anticonvulsivantes, imunossupressores e bloqueadores dos canais de cálcio. Alguns pacientes utilizavam simultaneamente mais de um tipo de medicamento, favorecendo o sinergismo ao aumento gengival, induzido por estes. Alguns apresentavam respiração bucal com aumentos gengivais típicos, localizados ou potencializados pela combinação com estes medicamentos. Após as aplicações de laser de CO2, os pacientes foram instruídos e reavaliados após quatro semanas. Este protocolo foi executado sucessivamente, até que os objetivos propostos fossem alcançados satisfatoriamente. Esse tipo de procedimento cirúrgico conservador, tendo o laser de CO2, como facilitador, proporcionou resultados surpreendentes e satisfatórios. O pós-operatório foi indolor e exangue na grande maioria dos casos, sem a necessidade de sutura ou de qualquer outro tipo de medicação. A potência utilizada nas aplicações variou entre 8 a 12W no modo contínuo e escaneado. A gengivoplastia foi eficaz e os dentes supostamente comprometidos por mobilidade ou heterotopismo foram preservados. O restabelecimento da função mastigatória e fonoarticulatória favoreceu a higienização e manutenção da saúde bucal dos pacientes / Abstract: Hyperplasia of the gingivae makes up about half of the proliferating lesions which occur of the mouth The health professionals in contact with patients that have these gum alterations should examine them meticulously until their etiology or any related dental misalignment is determined. The acceptance of the clinical diagnosis will show the ability of a person to deal with the local alterations and/or organic systems and will help with the prognosis and treatment plan. In this study, the clinical approach involved a team of doctors, nurses and odontologists working with a group of 18 patients manifesting gingival hyperplasia from the odontology and otolaryngology clinics at the Clinic Hospital at the Campinas State University (Unicamp). A biopsy of the gingival hyperplasia tissue of a previous incision was performed as a pre-operative step. Lab exams were requested according to the specific individual needs of each patient. After establishing diagnoses and the basic pathology of the prognosis, plans were elaborated for the treatment of the selected sites. Surgical procedures were performed using CO2 10,6µm laser under local anesthesia with the objective of aiding the reestablishment and control of normal physiological functions of the masticatory function, respiratory system and phoniatrics through gingivoplasties and orientation as to the importance of oral hygiene and in keeping these systems healthy. The power used in the applications were determined according to the necessities of each case, varying from 8 to 12W, depending upon the nature, place and extension of the enlarged gingivae. The number of CO2 laser applications needed for the treatment also followed the same criteria. Clinical evaluations, x-rays and photographs were taken before each application in order to establish posterior comparative standards. The patients were given anticonvulsant, immunosuppressant and calcium channel blocker medication. Some of the patients took more than one kind of medication, which helped the synergism of those drugs on the enlarged gingivae. Again, some patients had oral respiration typical of enlarged gingivae. The patients were reevaluated four weeks after finishing the laser treatment. This was repeated until the objectives were satisfactorily reached. This type of conservative surgical procedure, using a CO2 laser, gave surprisingly satisfactory results. The postoperative period was painless and bloodless in the majority of the cases with no need for sutures or any kind of medication. The gingivoplasties were efficient and the teeth supposedly compromised in mobility or misalignment were saved. The reestablishment of the masticatory functions and the ability to articulate phonemes helped the patients in the cleanliness and maintenance of their oral health / Mestrado / Ciencias Biomedicas / Mestre em Ciências Médicas
32

Resistencia a tração da união entre esmalte-botão e esmalte-bracket ortodonticos colados com resina autopolimerizavel para fracionamento de dentes inclusos

Moraes, Marcio de, 1966- 26 August 1998 (has links)
Orientador: Luis Augusto Passeri / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-24T02:31:40Z (GMT). No. of bitstreams: 1 Moraes_Marciode_D.pdf: 2385266 bytes, checksum: f251ca3dc313c1a13ef4a1a85589e56e (MD5) Previous issue date: 1998 / Resumo: O tratamento cirúrgico-ortodôntico de dentes inclusos visa levar o elemento dentário para a correta posição na arcada dentária, sem causar danos aos demais elementos dentais adjacentes, estabelecendo a estética e a função. Além de uma adequada técnica ctrúrgica,acorreta colagem do botão ou bracket ortodôntico, para tracionar o dente, é fundamental para se obter sucesso no tratamento. Este trabalho tem como objetivo verificar a eficiência de quatro procedimentos de colagem, avaliados através de um teste de tração in vitro. Aamostragem constitui-se de 132 dentes (pré-molares e caninos), em cujas faces vestibulares realizou-se condicionamento ácido e lavagem da. superfície com água destilada. Em seguida, a colagem do botão ou bracket ortodôntico foi efetuada. com resina composta otopolimerizável ou quimicamente polimerizável, nos seguintes grupos: 1) botão + resina fotopolimerizável (Z-100, 3M); 2) botão + resina quimicamente polimerizável (Concise, 3M); 3) bracket de policarbonato + resina fotopolimerizável (Z-100, 3M); e, 4) bracket de policarbonato + resina quimicamente polimerizável (Concise, 3M). Após 24 horas, em estufa (37°C) e 100% de umidade relativa do ar, cada amostra foi submetida a tal amociclagem (100 ciclos com temperatura variando entre SOC a 60°C) e armazenadas nos períodos de 1, 30 e90 dias. Após estes períodos foi efetuado o teste de tração na máquina de ensaio O Wolpert, a uma velocidade de 6mm/min., até ocorrer descolagem do botão ou bracket. Os resultados obtidos foram submetidos à análise de variância e ao teste de Tukey, de 5% de significância. Através da análise dos resultados pode-se concluir que a colagem do botão ortodôntico independente da resina utilizada, proporcionou maior resistência à tração. No entanto, o grupo que apresentou os piores resultados (colagem de bracket com resina Concise), ainda pode ser adequado para. o tracionamento, tendo em vista a pequena força de tração aplicada clinicamente / Abstract: The aim of this work was to verify in vitro the efficiency of four adhesive button procedures. The vestibular faces of hundred thirth two tooth were acid etched and washed with distilled water. The adhesion of the orthodontic button was made with light activated composite 'resin or cold-cure composite resin, according the groups: 1 ) button + light-cured composite resin (Z-1 00, 3M); 2) button + cold-cure composite resin (Concise, 3M); 3) bracket + light-cured composite resin; 4) bracket + cold-cure comppsite resin. After 24 hours in stove storage at 37°C and 100% of air relative humidity, each specimens was applied thermocycle (100 cycle with temperature ranged of SOC a 60°C) and stored in the period of 1, 30 and 90 days. Before this period was applied the traction testing in the Otto Wolperte, with 6mm/min. crosshead speed. The results showed that the button adhesion with cold-cure composite resin exhibited a significantly highet bond strength in the first two periods (1 and 30 days of stored). Bisides this, bracket showed the major bond strenght when associated with light-curede composit resin in the period of 90 days / Doutorado / Cirurgia Buco-Maxilo-Facial / Doutor em Clínica Odontológica
33

Influencia do aparelho ortodontico fixo, tipo multi-bandas, sobre a incidencia de Streptococcus nutans e suas aplicações na saude bucal

Tosello, Ana Luiza Bueno Barrichello 17 July 2018 (has links)
Orientador: Pedro Bertolini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-17T13:26:31Z (GMT). No. of bitstreams: 1 Tosello_AnaLuizaBuenoBarrichello_M.pdf: 1570000 bytes, checksum: 273d14b9004797d3f76006d7539ab277 (MD5) Previous issue date: 1977 / Resumo: Foram estudados neste trabalho, os efeitos do uso de aparelho ortodntico fixo, tipo multi-bandas, sobre o meio bucal, relativos a: incidencia de carie dentaria, alterações gengivais e variações ocorridas quanto ao numero de estreptococos e Streptococcus mutans ...Observação: O resumo, na íntegra poderá ser visualizado no texto completo da tese digital / Abstract: Not informed. / Mestrado / Ortodontia / Mestre em Ciências
34

AVALIAÇÃO DA FORÇA DE ATRITO ESTÁTICO EM BRAQUETES AUTOLIGADOS E CONVENCIONAIS ESTUDO IN VITRO / EVALUATE OF THE STATIC FRICTION FORCE IN SELFLIGATING AND CONVENTIONAL BRACKETS IN VITRO STUDY

Oliveira, Luiz Felipe Durand de 28 February 2011 (has links)
The aim of this study was to evaluate, by means the axial pull-out strength, the influence of using conventional metal brackets and metal and ceramic self-ligating, in the intensity of the frictional force generated when associated with orthodontic wires of circular and rectangular sections of different diameters. Three types of brackets were used in this work: metallic conventional (G1); metallic self-ligating (G2) and ceramic self-ligating (G3). Bars were made of polyethylene (10 cm long x 3.5 cm thick x 3.5 cm wide) where three brackets were bonded (canine, first and second premolars rights) previously aligned and leveled. The groups of brackets were associated with orthodontic wires, stainless steel (Cr-Ni) of circular and rectangular sections in three dimensions, F1: 0.020" circular, F2: 0.017 x 0.025 , F3: 0.019" x 0.025" rectangular, resulting Groups: G1F1, G1F2, G1F3, G2F1, G2F2, G2F3, G3F1, G3F2 and G3F3. For each type of bracket were prepared 10 specimens. All groups were tested in a universal testing machine (EMIC DL 2000). easurements of friction were obtained every 0.5 mm distance to travel a total of 5 mm. The values found were submitted to the analysis of Kruskal-Wallis and Tukey. The results showed that self-ligating brackets showed lower friction resistance when compared to conventional brackets used with circular and rectangular wire sections. The differences in the values of the friction encountered between conventional and selfligating brackets have a direct influence of association with the section of wire used. / O objetivo deste estudo foi avaliar, por meio de ensaio de tração, a influência do uso de braquetes convencionais metálicos e autoligados metálicos e cerâmicos, na intensidade da força de atrito gerado, quando associados a fios ortodônticos de secções circular e retangular em diferentes diâmetros. Três tipos de braquetes foram utilizados neste trabalho: convencional metálico (G1); autoligado metálico (G2) e cerâmico (G3). Foram confeccionados barras em polietileno (10 cm de comprimento x 3,5 cm de espessura x 3,5 cm de largura) onde foram colados três braquetes (canino, primeiro e segundo pré-molares superiores direitos) previamente alinhados e nivelados. Os grupos de braquetes foram associados a fios ortodônticos de aço inoxidável (Cr-Ni) de secções circulares e retangulares de três dimensões, F1: 0.020 circular; F2: 0.017 x 0.025 , F3: 0.019 x 0.025 retangulares, originando os grupos: G1F1, G1F2, G1F3, G2F1, G2F2, G2F3, G3F1, G3F2 e G3F3. Para cada tipo de braquetes foram confeccionados 10 corpos de prova. Todos os grupos foram testados em uma máquina de ensaios universais (Emic DL 2000) . As mensurações do atrito foram obtidas a cada 0,5 mm de deslocamento até percorrer um total de 5 mm. Os valores achados foram submetidos as análises de Kruskal-Wallis e Tukey. Os resultados demonstraram que os braquetes autoligados apresentaram menor resistência ao atrito em relação aos convencionais quando utilizados com fios de secções circular e retangular. As diferenças nos valores do atrito estático encontradas entre os braquetes autoligados e convencionais possuem influência direta com a secção e espessura do fio utilizado.
35

Aparelhos orais e aparelhos ortopédicos funcionais para tratamento da apnéia obstrutiva do sono em crianças: revisão sistemática Cochrane / Oral appliances and functional orthopaedies appliances for obstructive sleep apnoca in children

Carvalho, Fernando Rodrigues de [UNIFESP] January 2006 (has links) (PDF)
Made available in DSpace on 2015-12-06T23:44:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2006 / Introdução: A apnéia obstrutiva do sono é caracterizada pela ausência ou redução do fluxo aéreo pelo nariz ou boca durante o sono. Em crianças, os fatores de risco incluem hipertrofia adenotonsilar, obesidade, desordens neuromusculares e anomalias craniofaciais. O tratamento mais comum para a síndrome da apnéia obstrutiva do sono em crianças é a adenotonsilectomia. Este procedimento é limitado devido aos riscos cirúrgicos, principalmente em crianças com co-morbidades, e em alguns pacientes pode haver recorrência, devido a associação com problemas craniofaciais. Os aparelhos ortopédicos funcionais e os aparelhos orais têm sido usados em crianças que têm síndrome da apnéia obstrutiva do sono e anomalias craniofaciais. Tais aparelhos mudam a postura mandibular para anterior e aumentam potencialmente a via aérea superior, aumentando assim o espaço aéreo e melhorando a função respiratória. Objetivo: Avaliar a efetividade dos aparelhos orais e aparelhos ortopédicos funcionais para tratamento da apnéia obstrutiva do sono em crianças. Estratégia de busca: Uma sensível busca foi desenvolvida para Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library - Issue 2); PubMed (Janeiro de 1966 a Setembro de 2005); EMBASE (1980 a Setembro de 2005); Lilacs (1982 a Setembro de 2005); BBO - Bibliografia Brasileira de Odontologia (1986 a Setembro de 2005); SciELO (1997 a Setembro de 2005). Não houve restrição de idioma ou fonte de informação. Critério de seleção: Todos os ensaios clínicos randomizados ou quasi-randomizados comparando todos os tipos de aparelhos orais e aparelhos ortopédicos funcionais com placebo ou não-tratamento, em crianças de 15 anos ou mais jovens, cujo desfecho primário fosse redução do índice de apnéia/hipopnéia obstrutiva do sono para valores menores que 1 episódio por hora de sono medido pela polissonografia e cujos desfechos secundários fossem avaliação da melhora na relação dental e esqueletal, nos parâmetros do sono, na função cognitiva e fonoaudiológica, nos problemas comportamentais, qualidade de vida, efeitos colaterais, desistências e avaliação econômica. Extração de dados e análises: Os dados foram extraídos independentemente por dois revisores. Alguns autores foram contactados para informações adicionais. Para o ensaio clínico incluído, foi calculado risco relativo com 95% de intervalo de confiança para todos os desfechos dicotômicos. Resultados:Identificamos 384 estudos pela pesquisa eletrônica. Apenas um dos ensaios clínicos, que reportava resultados de vinte e três pacientes, foi incluído nesta revisão. Os dados disponíveis na publicação não responderam a todas as questões dessa revisão, mas algumas questões puderam ser respondidas e o tratamento mostrou-se eficaz quando comparado ao grupo controle. Conclusão do revisor: No momento, as evidências não são suficientes para se afirmar que os aparelhos orais ou os aparelhos ortopédicos funcionais são de fato efetivos no tratamento da apnéia obstrutiva do sono em crianças, entretanto, os aparelhos orais e ortopédicos funcionais devem ser usados em casos específicos como auxiliar no tratamento de crianças com anomalias craniofaciais, pois esse é um fator de risco para apnéia na criança. / Background: Obstructive sleep apnoea is marked by the absence or reduction of the airflow at the nose or mouth during sleep In children, risk factors include adenotonsillar hypertrophy, obesity, neuromuscular disorders and craniofacial anomalies The most common treatment for obstructive sleep apnea syndrome in childhood is adenotonsillectomy. This approach is limited by its surgical risks, mostly in children with comorbities and, in some patients, by recurrence that can be associated with craniofacial problems. Functional oral appliances and oral appliances have been used for patients who have obstructive sleep apnea syndrome and craniofacial anomalies because they change the mandible posture forwards and potentially enlarge upper airway and increase upper airway, improving the respiratory function. Objective: To assess the effectiveness of oral appliances and functional oral appliances for obstructive sleep apnea syndrome in children. Search strategy A sensitive search was developed for Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library - Issue 2); PubMed (January 1966 to September 2005); EMBASE (1980 to September 2005); Lilacs (1982 to September 2005); BBO-Bibliografia Brasileira de Odontologia (1986 to September 2005); SciELO (1997 to September 2005).There was no restriction of language or source of information. Selection criteria: All randomised or quasi-randomised controlled trials comparing all types of oral appliances and Functional oral appliances with placebo or no treatment, in children with 15 years old or younger, which primary outcome was reduction of apnoea to less than one episode per hour and which secondary outcomes were dental and skeletal relationship, sleep parameters improvement, cognitive and phonoaudiologic function, behavioral problems, drop outs and withdrawals, quality of life, side effects (tolerability), economic evaluation. Data collection & analysis: Data were independently extracted, by two reviewers (FRC & DLO). Authors were contacted for additional informations. For the trial included, relative risk with 95% confidence intervals were calculated for all important dichotomous outcomes. Main results: The initial search identified 384 trials. One of them, reporting results from a total of 23 patients, was suitable for inclusion in the review. Data provided in the published report, did not answer all questions from this review, but some of them were, and the treatment showed favourable to intervention compared to control group. Reviewers' conclusions: At this moment the evidences are not sufficient to state that the oral appliances and functional oral appliances are effective in the treatment of obstructive sleep apnea syndrome in children, however the oral appliances and functional oral appliances must be used in sellected patients as an auxiliary in the treatment to children who have craniofacial anomalies, because it is a risk factor for apnoea in children. / BV UNIFESP: Teses e dissertações
36

Resistência adesiva ao cisalhamento de brackets cerâmicos monocristalinos : estudo in vitro / Luís Filipe Siu Lon ; orientador, Olilon Guariza Filho

Lon, Luís Filipe Siu January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Bibliografia: f. 35-38 / Introdução: A crescente procura por tratamentos ortodônticos pelos adultos em busca de correção da oclusão e estética, tem aumentado a demanda no uso de rackets cerâmicos. O objetivo deste trabalho foi avaliar, in vitro, a Resistência Adesiva (RA) ao cisa / Abstract: The purpose of this study was to evaluate the Shear Bond Strength (SBS) and the adhesive failure mode of Radiance® (American Orthodontics, Sheboygan, Wisc) and Inspire Ice® (ORMCO, Orange, Calif) monocrystalline ceramic brackets and compare them
37

ESTUDO COMPARATIVO DAS ANGULAÇÕES E TORQUES DE BRAQUETES DE DIFERENTES MARCAS COMERCIAIS / Comparative study of angulation and inclination of different brackets trademarks

Zanesco, Alexandre 27 April 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:12Z (GMT). No. of bitstreams: 1 Alexandre Zanesco.pdf: 1035848 bytes, checksum: d02024f61764f0328225b9a073241130 (MD5) Previous issue date: 2008-04-27 / The purpose of this study was to compare the angulations and torques of orthodontic brackets from different trademarks in relation to the Roth s prescription and also in relation with the recommended values from the manufacturer. It was used 150 orthodontic metalic stainless steel brackets, from upper cuspid and incisors in its prescription and evaluated through a vertical Benchtop Measuring Projector in the Metrology laboratory of Dental Morelli Ltda. After collecting the results and the application of statistical test, it was obtained that values of torque found with the Roth´s prescription was similar between the manufacturer and the cuspid angulation has been shown higher values in comparison to that proposed from the author in the manufacturer Morelli, and for the teeth 2.1 and 2.2, the increased angulation was showed on Abzil manufacturer s bracket. On comparative values of torque obtained within all manufacturers, Unitek showed greater reliability in torque values than others. For angulation, the reliability of the same manufacture was not superious when compared to the other manufacturers. It was concluded that the differences on both torque and angulation to the author values and prescription of the manufacturers studies fall within the degree of advocated tolerance by a German association of orthodontic accessories. / O objetivo deste estudo foi comparar as angulações e torques de braquetes de marcas comerciais distintas em relação à prescrição de Roth e também em relação aos valores preconizados pelo fabricante. Foram utilizados 150 braquetes metálicos de aço inoxidável, de caninos e incisivos superiores na respectiva prescrição, avaliadas por meio de um perfilômetro. Após a coleta dos dados e aplicação do tratamento estatístico, os resultados demonstraram que os valores de torque obtidos com a prescrição de Roth foram semelhantes entre os fabricantes. Na angulação, os caninos superiores apresentaram valores acima do proposto pelo autor para o fabricante Morelli, e para os dentes 21 e 22, a angulação foi maior para o fabricante Abzil. Na comparação dos valores de torque obtidos com os valores recomendados pelos fabricantes, a Unitek demonstrou maior fidedignidade no torque comparada às demais marcas. Conclui-se que as diferenças tanto de torque quanto de angulação quando comparados aos valores do autor e à prescrição dos fabricantes, se enquadram dentro de um grau de tolerância preconizada por um órgão regulador de peças ortodônticas alemãs.
38

Efeito do tempo de fotoativação na resistência de união ao cisalhamento de bráquetes metálicos e cerâmicos à superfície cerâmica

Carvalho, Marcela Batista Pereira de 28 August 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade em Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2013. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2013-11-19T15:44:37Z No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-12-04T10:33:26Z (GMT) No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / Made available in DSpace on 2013-12-04T10:33:26Z (GMT). No. of bitstreams: 1 2013_MarcelaBatistaPereiraCarvalho.pdf: 19426211 bytes, checksum: dbf19bbb4b0468de7b3f32a7979dd79e (MD5) / O objetivo do presente estudo foi avaliar a resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica, analisando dois tempos de fotoativação com aparelho LED (light emitting diode). O ensaio de resistência de união foi realizado em bráquetes de aço inoxidável (Morelli), cerâmicos monocristalinos (Inspire ICE) e cerâmicos policristalinos (InVu). Os discos cerâmicos (IPS Empress Esthetic) incluídos em cilindros de resina acrílica foram condicionados com ácido fluorídrico gel a 10% por 60 segundos. Após a aplicação de silano, por 30 segundos, os bráquetes foram colados seguindo o protocolo recomendado para o compósito Transbond XT. Os corpos-de-prova, para cada tipo de bráquete, foram distribuídos aleatoriamente em 2 grupos (n=15) conforme o tempo de fotoativação, de 20 e 10 segundos, usando o aparelho LED Bluephase. Todos os corpos-de-prova foram armazenados a 37°C e 100% de umidade por 24 horas, posteriormente, termociclados (1000 ciclos, de 5°C à 55°C) e retornaram ao ambiente úmido de armazenamento. O teste de cisalhamento foi realizado após 24 horas na máquina universal de ensaio a uma velocidade de 1 mm/min. Em seguida, o Índice Remanescente de Adesivo (IRA) foi avaliado. Os dados foram submetidos à Análise de Variância e ao teste de Tukey (5%). Todos os bráquetes fotoativados por 20 segundos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes fotoativados por 10 segundos. Os bráquetes cerâmicos monocristalinos apresentaram valores de resistência de união significativamente (p<0,05) superiores aos bráquetes cerâmicos policristalinos e de aço inoxidável, sendo estes, estatisticamente semelhantes (p>0,05) quando fotoativados por 20 segundos. Para o tempo de fotoativação de 10 segundos, os bráquetes cerâmicos policristalinos apresentaram valores superiores (p<0,05) aos de aço inoxidável. Enquanto nos grupos de 20 segundos de tempo de fotoativação, o escore 1 (IRA) foi observado com predominância para os bráquetes de aço inoxidável e cerâmicos monocristalinos, e o escore 3 para o bráquete cerâmico policristalino, nos grupos de 10 segundos, o bráquete cerâmico monocristalino apresentou predominância do escore 1, e escore 3 para os bráquetes de aço inoxidável e cerâmicos policristalinos. Pôde-se concluir que o tempo de fotoativação teve influência significativa na resistência de união de bráquetes metálicos e cerâmicos à superfície cerâmica e que os bráquetes cerâmicos monocristalinos apresentaram os maiores valores de resistência de união. ______________________________________________________________________________ ABSTRACT / The aim of this study was to evaluate the bond strength of metallic and ceramic brackets bonded to ceramic, by testing two photoactivation times using a LED (light emitting diode) curing unit. Bond strength testing was performed on stainless steel brackets (Morelli), monocrystalline ceramic brackets (Inspire ICE), and polycrystalline ceramic brackets (InVu). Disc-shaped-ceramic specimens (IPS Empress Esthetic) embedded in acrylic resin blocks were etched with 10% hydrofluoric acid gel for 60 seconds. After application of silane for 30 seconds, brackets were bonded following the protocol recommended for Transbond XT. Specimens for each bracket type were assigned to two groups (n=15), according to the photoactivation times: 20 seconds or 10 seconds, using a Bluephase LED unit. All specimens were stored at 37°C and 100% relative humidity for 24 hours, then thermocycled (1,000 cycles, 5°C to 55°C), and they returned to the humid storage conditions. Shear bond testing was carried out after 24 hours with a universal testing machine at a crosshead speed of 1-mm/min. Adhesive Remnant Index (ARI) scores were evaluated. Data were subjected to two-way ANOVA and Tukey's test. All bracket types photoactivated for 20 seconds showed significantly (p<0.05) higher bond strength compared to specimens photoactivated for 10 seconds. Monocrystalline brackets showed significantly (p<0.05) higher bond strength compared to polycrystalline and stainless steel brackets, which are statistically similar (p>0,05) when photoactivated for 20 seconds. For 10 seconds photoactivation time, the polycrystalline ceramic brackets showed higher values (p<0.05) than stainless steel brackets. For the 20 second photoactivation time group, an ARI score 1 was observed with predominance for SS and monocrystalline brackets, and score 3 for polycrystalline brackets; for the 10 second photoactivation time group, an ARI score 1 was observed with predominance for the monocrystalline brackets, and score 3 for stainless steel and polycrystalline brackets. In conclusion, photoactivation time had significant influence on the bond strength of metallic and ceramic brackets bonded to a ceramic surface, and monocrystalline brackets showed the highest bond strength values.
39

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Moresca, Ricardo Cesar 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014", 0.016", 0.018", 0.020" e 0.019" x 0.025"). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.
40

"Estudo dos efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento utilizando-se a técnica MBT" / Study of the effects of active and passive lacebacks in the biomechanics of the leveling phase using the MBT technique

Ricardo Cesar Moresca 09 June 2006 (has links)
O objetivo deste trabalho foi estudar os efeitos dos lacebacks ativos e passivos na biomecânica da fase de nivelamento, utilizando-se a técnica MBT. A amostra foi constituída de 29 sujeitos de pesquisa (22 do gênero feminino e 7 do gênero masculino), brasileiros, leucodermas e pardos, portadores de má oclusão de Classe I e com idade média de 15 anos e 5 meses. O tratamento ortodôntico foi planejado com as extrações dos primeiros pré-molares e, durante a fase estudada, foram empregados apenas fios de aço inoxidável (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). Os recursos de ancoragem utilizados para os arcos dentários superior e inferior foram, respectivamente, o aparelho extrabucal tipo IHG e o arco lingual fixo. De acordo com a indicação dos lacebacks, a amostra foi dividida em quatro grupos: grupo I – 14 sujeitos que utilizaram lacebacks ativos no arco dentário superior; grupo II – 9 sujeitos que utilizaram lacebacks passivos no arco dentário superior; grupo III – 19 sujeitos que utilizaram lacebacks ativos no arco dentário inferior e grupo IV – 10 sujeitos que utilizaram lacebacks passivos no arco dentário inferior. Para cada indivíduo da amostra foram tomadas duas telerradiografias laterais, uma ao início e outra ao término da fase de nivelamento, com um intervalo médio de 21 meses. Os dados foram coletados utilizando-se o método cefalométrico computadorizado. Para a análise de erros, o método cefalométrico foi repetido em todos os sujeitos da amostra, pelo mesmo operador, com um intervalo mínimo de 15 dias entre as medidas. Os resultados indicaram que as variações observadas foram compatíveis com as estimativas de erros operacionais em estudos cefalométricos. Após a análise estatística e a interpretação dos resultados, verificou-se que, no grupo I, apenas a coroa do primeiro molar superior sofreu um movimento mesial e que tanto a coroa como a raiz do incisivo central superior apresentaram um movimento em direção lingual. No entanto, as inclinações destes dentes não foram alteradas. No grupo II, o primeiro molar superior se manteve estável e somente a coroa do incisivo central superior se movimentou em direção lingual, produzindo uma rotação horária deste dente. No grupo III, observou-se uma mesialização, tanto da coroa como da raiz, e extrusão do primeiro molar inferior, enquanto a posição do incisivo central inferior permaneceu inalterada. As inclinações destes dentes também não foram alteradas. No grupo IV, verificou-se que nem o primeiro molar inferior nem o incisivo central inferior apresentaram variações no sentido ântero-posterior. Verticalmente, houve extrusão apenas do primeiro molar inferior. / The purpose of this study was to evaluate the effects of active and passive lacebacks in the biomechanics of the leveling phase, using the MBT technique. The sample was composed of 29 Brazilian subjects (22 female and 7 male), Caucasian, with Class I malocclusion and mean age of 15 years and 5 months. The orthodontic treatment was planned with the extraction of the first premolars, and the leveling phase was performed with stainless steel wire only (0.014”, 0.016”, 0.018”, 0.020” e 0.019” x 0.025”). The anchorage control devices used in the upper and lower arches were, respectively, the IHG extraoral appliance and the fixed lingual arch. According to the type of laceback prescription, the sample was divided into four groups: group I – 14 subjects in which active lacebacks were used in the upper arch; group II – 9 subjects in which passive lacebacks were used in the upper arch; group III – 19 subjects in which active lacebacks were used in the lower arch; group IV – 10 subjects in which passive lacebacks were used in the lower arch. For each subject of the sample two lateral cephalometric radiographs were taken: one at the beginning and another at the end of the leveling phase, with a mean interval of 21 months. The data were collected using the resources of computerized cephalometry. To perform the analysis of errors, the cephalometric method was repeated in all subjects of the sample, by the same operator, with a minimum interval of 15 days between the measurements. The results revealed that the observed variations were compatible with the estimates of operational errors in cephalometric studies. After statistical analysis and interpretation of the results, it was observed that in group I, only the crown of the upper first molar presented a mesial movement. As to the upper central incisor, both the crown and the root presented a lingual movement. However, the inclination of these teeth was not affected. In group II, the upper first molar remained stable and only the crown of the upper central incisor moved lingually, leading to a clockwise rotation of this tooth. In group III, a mesial movement of both the crown and the root of the lower first molar was observed, along with its extrusion, whereas the position of the lower central incisor remained unchanged. The inclination of these teeth was not affected either. In group IV, it was observed that neither the lower first molar nor the lower central incisor experienced variations in the anteroposterior sense. Vertically, there only was extrusion of the lower first molar.

Page generated in 0.0554 seconds