• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 3
  • 2
  • 2
  • Tagged with
  • 16
  • 9
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Fukttillstånd i olika ytterväggar med tre olika fasadsystem : En parameterstudie med Wufi / Moisture conditions in different exterior walls with three different façade systems : A parameter study with Wufi

Augustsson, Andreas, Adolfsson, Kristian January 2015 (has links)
Ett stort antal av miljonprogrammets byggnader är idag i behov av renovering. Då många av dessa byggnader har en hög energiförbrukning kan det vara lönsamt att samtidigt energieffektivisera byggnaderna, bland annat genom tilläggsisolering. Det är av stor vikt att noggrant undersöka hur byggnaderna påverkas ur fukthänsyn innan nya fasadsystem tas i bruk för att undvika framtida fuktrelaterade skador.Syftet är att undersöka tre fasadsystem utifrån hur olika fuktbelastningar, väderstreck, tilläggsisoleringar och stommaterial påverkar ytterväggars fukttillstånd och risken för mikrobiell tillväxt. Även hur väl de olika fasadsystemen lämpar sig för att uppföras på en befintlig stomme i trä-, lättbetong- och betongstomme har undersökts. För att undersöka detta har fuktsimuleringar gjorts i fuktberäkningsprogrammet Wufi och resultaten har analyserats genom jämförelse av RF-kurvor samt riskbedömning för mögeltillväxt i Wufi Bio.En övergripande slutsats är bland annat att inläckage av slagregn är en stor belastning för fasadsystemen. Systemens fuktsäkerhet beror till stor del på dess förmåga att hantera inläckaget.Studien visar även att en fungerande ventilerad luftspalt, en god dränerande funktion eller en konstruktion med genomgående relativt ångöppna material har förmågan att hantera inläckage av slagregn effektivt. / A large number of buildings built under “miljonprogrammet” is today in need of renovation. With their high energy consumption it is also considered profitable to improve the buildings energy efficiency e.g. by additional insulation. It is however important to thoroughly evaluate potential damp issues that might arise as a result of these improvements before starting to implement a new building exterior.The aim of this study was to investigate three different façade systems based on how their moisture content and risk for mould growth are affected by different moisture loads, orientation, and additional insulation. Included is also a performance evaluation for each building exterior solution mounted on existing structure of wood, lightweight concrete and concrete structure. Damp simulations were done with the program Wufi and the results were then analysed by comparison to RF-curves in combination with risk assessments of the growth of mould with “Wufi Bio”.The overall conclusion shows that leakage due to torrential rain poses a great strain on building exterior systems. A solutions damp proof quality is largely dependent on its ability to withstand leakage from outer sources.The study also shows that a well ventilated cavity wall, sufficient drainage or a construction of exclusively vapour open materials has a positive impact on the amount of leakage.
12

Shear strength of prestressed concrete beams without shear reinforcement : A comparison between equations / Tvärkraftskapacitet av förspända betongbalkar utan skjuvarmering : En jämförelse mellan ekvationer

Azad, Bawan January 2021 (has links)
A new version of EN 1992-1-1, Eurocode 2 for Design of Concrete Structures, is under development and one of the most discussed topics is shear capacity for prestressed concrete beams without shear reinforcement, partly because shear failure occurs suddenly and can have catastrophic consequences. For the new version of Eurocode, there are a total of three proposed equations to replace the two equations that currently exist in EN 1992-1-1 for shear capacity of prestressed concrete beams without shear reinforcement. One of the proposed equations is intended to replace the equation intended for beam regions where bending cracks do not occur. The other two equations are proposed for beam regions where bending cracks occur. One of the proposed equations for beam regions with bending cracks, is based on critical shear crack theory and takes the normal force in consideration, while the other equation for beam regions with bending cracks is like the one found today in Eurocode, an empirical equation, where the contribution of normal force is empirical. In this thesis, all equations have been set against each other and compared with the help of nonlinear finite element analyzes and experiments which Dr. De Wilder has done in his doctoral thesis. The impact of the prestressing force on the shear force capacity of beams has also been investigated. The results show that the equations for beam regions that do not have bending cracks give identical shear force capacities. While the equation which is based on critical shear crack theory takes the shear span into consideration and captures the effect of the shear span correctly, which the other proposed equation and the one found in Eurocode today do not and are on the unsafe side for increasing shear spans. Furthermore, it turned out that the equation which is based on critical shear crack theory was rather conservative, while the equation that exists today in Eurocode gives approximately the same shear capacity as the other proposed equation. Furthermore, it was found that if the amount of longitudinal reinforcement is reduced, at the same time as the prestressing force is unchanged, an insignificant reduction in the shear capacity on prestressed concrete beams is obtained. / En ny version av EN 1992-1-1, Eurokod 2 Dimensionering av betongkonstruktioner, är under utveckling och ett av de mest diskuterade ämnena är tvärkraftskapacitet för förspända betongbalkar utan skjuvarmering, bland annat eftersom huvudspänningsskjuvbrott uppstår plötsligt och kan få katastrofala konsekvenser. Till den nya versionen av Eurokoden finns det totalt tre föreslagna ekvationer för att ersätta de två ekvationer som för närvarande finns i EN 1992-1-1 för tvärkraftskapacitet för förspända betongbalkar utan skjuvarmering. En av de föreslagna ekvationerna är tänkt att ersätta ekvationen avsedd för balkregioner där böjsprickor ej uppstår. De andra två ekvationerna är föreslagna för balkregioner där böjsprickor uppstår. En av de föreslagna ekvationerna för balkregioner med böjsprickor är baserad på kritisk skjuvsprickteorin och tar hänsyn till normalkraftens bidrag till tvärkraftskapaciteten, medan den andra föreslagna ekvationen för balkregioner med böjsprickor är likt den som idag finns i Eurokoden, en empirisk ekvation, där normala kraftens bidrag är baserad på ett empiriskt tillägg. I detta examensarbete har alla ekvationer ställts mot varandra och jämförts med hjälp utav icke-linjär finit-elementanalyser samt experiment som Dr. De Wilder gjort i sin doktorsavhandling. Vidare har också förspänningskraftens påverkan på balkars tvärkraftskapacitet undersökts. Resultaten visar att ekvationerna för balkregioner som ej har böjsprickor ger identiska tvärkraftskapaciteter. Medan ekvationen som är baserad på kritisk skjuvsprickteorin tar hänsyn till skjuvspännvidd och fångar effekten av skjuvspännvidden korrekt, vilket den andra föreslagna ekvationen och den som finns i Eurokoden idag inte gör och är på den osäkra sidan för ökad skjuvspännvidd. Dessutom visade det sig att ekvationen som är baserad på kritisk skjuvsprickteori är tämligen konservativ, medan ekvationen som finns idag i Eurokoden ger ungefär samma tvärkraftskapacitet som den andra föreslagna ekvationen. Vidare visade det sig att ifall man minskar mängden längsgående armering, samtidigt som förspänningskraften är oförändrad, så fås en obetydlig minskning utav tvärkraftskapaciteten på förspända betongbalkar.
13

Modellering av grävpålar i Plaxis 2D : En parameterstudie applicerad på nya Vårbybron, Stockholm / Modelling of bored piles in Plaxis 2D : A parametric analysis applied at the new bridge Vårbybron, Stockholm

Johansson, Josefin, Wennberg, Matilda January 2021 (has links)
I samband med Förbifart Stockholm och Tvärförbindelse Södertörn förväntas en flaskhals skapas vid Vårbybron i södra Stockholm. För att förhindra överbelastning planeras en nybyggnation där pålgrundläggning med grävpålar föreslås. Markförhållanden är ovanliga i Stockholm, med över 100 meter ned till berg. Komplexa omständigheter i området gör det nödvändigt att analysera markrörelser som verkar på grundläggningen. Syftet med studien är att undersöka horisontella- och vertikala sättningar vid ett brolandfäste. Syftet är vidare att analysera vilken typ av numerisk konstitutiv modell som är lämplig med hänsyn till studiens specifika fall och område; Mohr-Coulomb (MC), Hardening Soil (HS) och Hardening Soil med small-strain stiffness (HSS). Slutligen ska jordparametrarnas väsentlighet avgöras i en parameterstudie. Sonderingsdata tillämpas i studien för att skapa en jordlagermodell i AutoCAD Civil 3D 2019 Metric och vidare simulering av sättningar i Plaxis 2D. Vid modellering av sättningar i förekommande geologi rekommenderas att en avancerad modell används, med fördel HSS. Däremot kräver mer avancerade modeller noggranna indata för tillförlitligt resultat och ytterligare tester för styvhetsparametrar bör utföras. I detta projekt kan dyrare tester tänkas sänka slutgiltig budget, eftersom underskattning av moduler i djupa och fast lagrade jordar baserade på konservativt valda moduler ger upphov till en dyrare konstruktion. / In conjunction with the opening of the Stockholm Bypass and Tvärförbindelse Södertörn, a bottleneck is expected at the bridge Vårbybron in southern Stockholm. To prevent traffic congestion, a new construction is planned where pile foundation consisting of bored piles is proposed. The ground conditions are unusual and not typical for Stockholm involving over 100 meters distance to rock. Complex circumstances in the area makes it complicated as well as necessary to analyze ground movements. The aim of the study is to investigate horizontal- and vertical settlements at a bridge abutment. The aim is further to analyze which type of numerical constitutive model that is appropriate with respect to the specific case and area; Mohr-Coulomb (MC), Hardening Soil (HS) and Hardening Soil with small-strain stiffness (HSS). Finally, the significance of the soil parameters is to be determined in a parameter analysis. Results from soundings are used to create a geological model in AutoCAD Civil 3D 2019 Metric. Furthermore, simulation of settlements in Plaxis 2D is performed. It is recommended to apply advanced models for this type of geology, advantageously HSS. However, more advanced models require accurate input data to obtain reliable results, and additional tests for stiffness parameters must be performed for accuracy in the results. In this project, more expensive tests can be thought of as lowering the final budget, as underestimation of modules in deep and stiff soils based on conservatively selected modules leads to an unnecessarily expensive construction.
14

Ein Beitrag zur Untersuchung des Verhaltens dünner Flüssigkeitsfilme nahe gekrümmten Substratoberflächen / A contribution to the investigation of thin liquid layer behaviour at curved solid edges

Sommer, Oliver 05 November 2014 (has links) (PDF)
In der vorliegenden Arbeit wurde das Verhalten dünner Flüssigkeitsfilme an gekrümmten Substratoberflächen durch experimentelle Beschichtungsversuche basierend auf der non-invasiven laserinduzierten Fluoreszenzmesstechnik und durch numerische Filmsimulationen mit Hilfe des Volume-of-Fluid Mehrphasenmodells untersucht. Besonderes Interesse galt dabei dem Finden optimaler Einflussgrößenkombinationen zur Reduzierung des Fettkanten-Effekts. In der hierfür durchgeführten Parameterstudie wurden sowohl Applikationsparameter wie der Kantenrundungsradius und die Applikationsschichtdicke als auch Stoffparameter der untersuchten Flüssigkeit wie die Viskosität und die Oberflächenspannung variiert. Neben qualitativen Beschreibungen der entstandenen Fettkantengestalten sind als Resultate auch Größen zur Quantifizierung der Fettkanten festgelegt worden und systematisch dargestellt. Es konnte nachgewiesen werden, dass ungünstige und geeignete Parameterkonfigurationen existieren, welche prägnante bzw. kaum auffällige Fettkanten erzeugen, insbesondere im Experiment. Über die dabei eingreifenden Mechanismen der zugrundeliegenden Strömungen wurden konkrete Hypothesen aufgestellt, auch um die resultierenden Proportionalitäten der Fettkantengrößen bezüglich der Einflussgrößen zu plausibilisieren. Weiterhin konnte eine Aussage über die Signifikanz der untersuchten Einflussgrößen getroffen werden. Abschließend wurde eine geeignete dimensionslose Kenngröße generiert, um den Fettkanten-Effekt parameterübergreifend beschreiben zu können, wodurch mittels der Ähnlichkeitstheorie auch eine gewisse Abschätzung des Fettkanten-Effekts ermöglicht wird. / In this study the behaviour of a thin liquid layer at a curved solid edge was examined by experimental coating investigations based on the laser-induced fluorescence technique and by numerical film simulations based on the Volume-of-Fluid multiphase flow model, respectively. The main motivation was to find optimal combinations of influencing quantities to reduce the fat-edge effect. Therefore a study of these quantities was performed, in which application parameters like edge radii of curvature and application layer thicknesses as well as determining liquid properties like viscosity and surface tension have been varied. Results are described qualitatively at corresponding fat-edge shapes and quantified by suitable fat-edge parameters, which had to be identified and selected. It could be shown that adverse and appropriate influencing parameter combinations exist, which generate conspicuous and less distinctive fat-edges, respectively - especially in laboratory experiments. The experimental findings and proportionalities regarding fat-edge shapes and dimensions are found to be physically plausible. Furthermore an order of significance of the influencing quantities established. Eventually, a dimensionless quantity was derived by dimensional analysis, which describes the fat-edge effect. Thus, the fat-edge effect has also been described by the application of similarity theory and the corresponding dimenionless number, respectively.
15

Ein Beitrag zur Untersuchung des Verhaltens dünner Flüssigkeitsfilme nahe gekrümmten Substratoberflächen

Sommer, Oliver 17 October 2014 (has links)
In der vorliegenden Arbeit wurde das Verhalten dünner Flüssigkeitsfilme an gekrümmten Substratoberflächen durch experimentelle Beschichtungsversuche basierend auf der non-invasiven laserinduzierten Fluoreszenzmesstechnik und durch numerische Filmsimulationen mit Hilfe des Volume-of-Fluid Mehrphasenmodells untersucht. Besonderes Interesse galt dabei dem Finden optimaler Einflussgrößenkombinationen zur Reduzierung des Fettkanten-Effekts. In der hierfür durchgeführten Parameterstudie wurden sowohl Applikationsparameter wie der Kantenrundungsradius und die Applikationsschichtdicke als auch Stoffparameter der untersuchten Flüssigkeit wie die Viskosität und die Oberflächenspannung variiert. Neben qualitativen Beschreibungen der entstandenen Fettkantengestalten sind als Resultate auch Größen zur Quantifizierung der Fettkanten festgelegt worden und systematisch dargestellt. Es konnte nachgewiesen werden, dass ungünstige und geeignete Parameterkonfigurationen existieren, welche prägnante bzw. kaum auffällige Fettkanten erzeugen, insbesondere im Experiment. Über die dabei eingreifenden Mechanismen der zugrundeliegenden Strömungen wurden konkrete Hypothesen aufgestellt, auch um die resultierenden Proportionalitäten der Fettkantengrößen bezüglich der Einflussgrößen zu plausibilisieren. Weiterhin konnte eine Aussage über die Signifikanz der untersuchten Einflussgrößen getroffen werden. Abschließend wurde eine geeignete dimensionslose Kenngröße generiert, um den Fettkanten-Effekt parameterübergreifend beschreiben zu können, wodurch mittels der Ähnlichkeitstheorie auch eine gewisse Abschätzung des Fettkanten-Effekts ermöglicht wird. / In this study the behaviour of a thin liquid layer at a curved solid edge was examined by experimental coating investigations based on the laser-induced fluorescence technique and by numerical film simulations based on the Volume-of-Fluid multiphase flow model, respectively. The main motivation was to find optimal combinations of influencing quantities to reduce the fat-edge effect. Therefore a study of these quantities was performed, in which application parameters like edge radii of curvature and application layer thicknesses as well as determining liquid properties like viscosity and surface tension have been varied. Results are described qualitatively at corresponding fat-edge shapes and quantified by suitable fat-edge parameters, which had to be identified and selected. It could be shown that adverse and appropriate influencing parameter combinations exist, which generate conspicuous and less distinctive fat-edges, respectively - especially in laboratory experiments. The experimental findings and proportionalities regarding fat-edge shapes and dimensions are found to be physically plausible. Furthermore an order of significance of the influencing quantities established. Eventually, a dimensionless quantity was derived by dimensional analysis, which describes the fat-edge effect. Thus, the fat-edge effect has also been described by the application of similarity theory and the corresponding dimenionless number, respectively.
16

Second-order FE Analysis of Axial Loaded Concrete Members According to Eurocode 2 / Analys av axial belastade betongkonstruktioner med finita elementmetoden enligt Eurokod 2

Yosef Nezhad Arya, Nessa January 2015 (has links)
A nonlinear finite element analysis was performed for an axial loaded reinforced concrete column subjected to biaxial bending taking into account second-order effects. According to Eurocode there are two ways to take second-order effects into consideration: nonlinear FE analysis and hand calculation based on the simplified methods explained in Eurocode 2. Since simulating this kind of structures in ABAQUS is difficult, several simulations were made to find the correct model with satisfying accuracy. The nonlinear analysis focused on material modelling of concrete and its nonlinear behaviour. The simulation took into consideration the inelastic behaviour of concrete along with the confinement effect from transverse reinforcement. The finite element model was verified by comparing the obtained results from FEA to the results from a benchmark experiment. The mean values needed for simulating the FE model was derived from the mean compressive strength of concrete. After verification, another FE model using design parameters was analysed and the results were compared to the results from calculations based on simplified methods according to Eurocode 2 to see how much they agreed with each other. In a parametric study, the effect of eccentricity, compressive and tensile strength of concrete, fracture energy, modulus of elasticity, column cross-section dimension and length, steel yield stress and stirrup spacing were studied. A comparison between outcomes from the simplified methods and ABAQUS, calculated with design parameters showed that the bearing capacity from FE analysis was 21-34 % higher than the one obtained with the simplified methods. It is recommended that in further studies, analyse different slender reinforced concrete column with different L/h with FE-simulation to investigate if FEA always gives a more accurate result. For this case, and probably for columns with complex geometries, a finite element analysis is a better choice. / En icke-linjär finitelementanalys för en armerad betongpelare utsatt för tvåaxlig böjning genomfördes med hänsyn till andra ordningens effekter. Enligt Eurokoder finns det två sätt att iaktta andra ordningens effekter: icke-linjär analys och handberäkning baserad på de förenklade metoderna förklarad i Eurokod 2. Eftersom det är svårt att simulera den här typen av konstruktioner i ABAQUS, så har flera simuleringar utgjorts för att finna ett modell med acceptabelt noggrannhet. Den icke-linjära analysen fokuserade på korrekt materialmodell av betong och dess icke-linjära beteende. Modellen tog hänsyn till betongens oelastiska beteenden och inkluderade fleraxiella effekten. Finitelementmodellen verifierades genom att jämföra de erhållna resultaten från FEA till resultaten från ett försök. Värden som behövdes för att simulera FE-modellen härleddes från betongens medeltryckhållfasthet. Efter att referensmodellen var verifierad, ytterligare en FE-modell, som inkluderade designparametrar, analyserades och resultaten jämfördes med resultaten från beräkningar baserade på förenklade metoderna enligt Eurokod 2 för att se hur mycket de stämde överens med varandra. I en parameterstudie har effekten av excentricitet, tryck- och draghållfasthet av betong, brottenergi, elasticitetsmodul, pelarens tvärsnittsdimension och längd, stålsträckgränsen och centrumavstånd på byglar studerat. En jämförelse mellan resultaten från de förenklade metoderna och ABAQUS, beräknade med designparametrar visade att bärighetförmågan från FE-analys var 21-34% högre än den som erhålls med de förenklade metoderna. Det rekommenderas att i fortsatta studier, analysera flera slanka armerade betongpelare med olika L/h med FE-simulering för att undersöka om FEA alltid ger ett nogrannare resultat. För denna studie, och förmodligen för pelare med komplexa geometrier, är en FE-analys ett bättre val.

Page generated in 0.5904 seconds