• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 282
  • 13
  • 4
  • 1
  • Tagged with
  • 303
  • 284
  • 223
  • 198
  • 123
  • 111
  • 109
  • 99
  • 44
  • 38
  • 34
  • 34
  • 31
  • 28
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Caracterização de íons majoritários em material particulado atmosférico da região de Caetité, Bahia

Sousa, Yara Simone Chaves 05 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-30T17:42:26Z No. of bitstreams: 1 Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-31T12:39:01Z (GMT) No. of bitstreams: 1 Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / Made available in DSpace on 2014-10-31T12:39:02Z (GMT). No. of bitstreams: 1 Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / CNPq / Este trabalho teve como objetivo determinar íons majoritários no material particulado proveniente da região de Caetité. A coleta das amostras foi realizada através de amostradores do tipo ciclone com corte MP1 e MP2,5, Hi-Vol MP2,5 e Hi- Vol com impactador em cascata, utilizando vazão de 10 L min-1 para os amostradores ciclone e 1,13 m3 min-1 para os amostradores Hi-Vol MP2,5 e Hi-Vol com impactador em cascata e período de amostragem de 24 horas nos dias 12 a 26 de novembro de 2010. As espécies quantificadas foram os íons fluoreto, lactato, acetato, propionato, formiato, butirato, piruvato, cloreto, nitrato, succinato, sulfato, oxalato, fosfato, citrato, lítio, sódio, amônio, potássio, magnésio e cálcio. A quantificação dessas espécies foi realizada através de um cromatógrafo de íons de duplo canal. De acordo com os níveis encontrados no material particulado de ciclone MP1 e MP2,5, as espécies predominaram na fração de tamanho menor que 1 µm, com exceções apenas para NO3-, SO42-, Na+ e Ca2+ que estiveram distribuídos nas duas faixas de tamanho. Os níveis encontrados nas partículas fracionadas por tamanho foram maiores para as espécies com diâmetro aerodinâmico menor que 0,49 µm. Foram observadas trajetórias de massas de ar do tipo oceânica e continental, sendo a primeira a de maior contribuição no período de amostragem. No entanto, não foi comprovada contribuição marinha significativa para as SO42-, K+, Mg2+ e Ca2+. A relação iônica equivalente (ânions/cátions) para as amostras nos diferentes amostradores foi menor que um, evidenciando caráter básico do MP da região de Caetité. Com base nas correlações de Pearson e PCAs, foram identificadas como prováveis fontes emissões biogênicas, como metabolismo de plantas, fungos e bactérias, fontes antrópicas, como emissão por veículos movidos a diesel (usados no transporte da torta amarela de urânio) e emissão de partículas provenientes da extração de minério de urânio e ainda partículas provenientes da ressuspensão do solo. As espécies estudadas apresentaram fluxo de deposição elevado, principalmente para ânions inorgânicos e íons alcalinos, indicando que a deposição seca foi um mecanismo de remoção importante no período de coleta. / This work aimed to determine majority ions in the particulate matter from the region of Caetité-BA. The sample collection was executed through PM1 e PM2.5 cyclone samplers, Hi-Vol PM2.5 and Hi-Vol cascade impactor, using flow rate of 10 L min-1 for cyclone samplers and 1.13 m3 min-1 for the Hi-Vol samplers, during 24 hours 12th 26th November 2010. The quantified species were fluoride, lactate, acetate, propionate, formate, butyrate, pyruvate, chloride, succinato, sulfate, oxalate, phosphate, citrate, lithium, sodium, ammonium, potassium, magnesium and calcium by an ion chromatograph coupled to conductivity detector. According to the levels found in the particulate matter of cyclone PM1 and PM2.5, species predominated in the fraction with size less than 1 µm, with exceptions only for NO3-, SO42-, Na+ and Ca2+ that were distributed in the two size fractions. The levels found in the particles were fractionated by size larger for species with aerodynamic diameter less than 0.49 µm. The equivalent ion balance (anions/cations) for the samples in the different samplers was less than one, evidencing the basic character for particulate matter from Caetité region. Based on Pearson correlation and PCAs were identified as probable sources to be biogenic emissions, such as metabolism of plants, fungi and bacteria, as well as, anthropogenic sources such as emissions from diesel-powered vehicles (used to transport of the yellow cake of uranium and yet particles descendant from the resuspension of soil. The species studied showed high flow deposition, mainly for inorganic anions and alkali ions, indicating that dry deposition was a major removal mechanism in the collection period.
72

Origem e composição da matéria orgânica particulada no complexo estuarino-lagunar de Mundaú-Manguaba utilizando lipídios como marcadores moleculares / Origin and composition of particulate organic matter in the estuarine-lagoon complex Mundaú-Manguaba using lipids as molecular markers

Talitha Lopes Ferreira da Costa 23 March 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Complexo Estuarino Lagunar Mundaú-Manguaba está sofrendo um processo acelerado de degradação ambiental devido a muitas atividades antrópicas como crescimento urbano desordenado, processamento de cana-de-açúcar, pecuária, efluentes industriais e domésticos. O objetivo deste trabalho é avaliar a composição e distribuição do material particulado em suspensão através de traçadores geoquímicos orgânicos para identificar as fontes potenciais e os padrões de mistura da matéria orgânica no CELMM durante duas campanhas: uma realizada no período seco e a outra no período úmido. As amostras de água foram coletadas na superfície (< 1 m de profundidade), utilizando garrafas de vidro de 4L de capacidade. Os n-alcoois, esteróis e ácidos graxos foram extraídos por Soxhlet e analisados por cromatografia em fase gasosa acoplada a espectrometria de massas. Considerando os resultados obtidos, constatou-se que há uma predominância de matéria orgânica autóctona em ambos os períodos de amostragem no sistema em questão. Contudo, também foi observada a presença de fontes alóctonas e antrópicas, tendo estas uma menor influência durante o período seco. / The Mundaú-Manguaba estuarine lagoon system is located in Maceió, Alagoas, Brazil. This region has been suffering an accelerated process of environmental degradation through many antropic activities like urban growth, sugar-cane processing, cattle breeding, industrials waste and sewage. The aim of this work is to evaluate the suspended particulate matter composition and distribution with organic geochemistry markers to identify the potential sources and mixing processes in the system during the wet and the dry period. The water samples were collected at the surface (<1m of depth), using a 4L glass bottle. Lipids were extracted by Soxhlet and quantified by gas chromatography-mass spectrometry. Considering the obtained results, a predominance of autochthonous sources of organic matter was established for the system. However, the presence of alochthonous and anthropic also was observed with lower influence during the dry period.
73

Avaliação do uso de diferentes modelos receptores com dados de PM2,5 : balanço químico de massa (BQM) e fatoração de matriz positiva (FMP)

Trindade, Camila Carnielli 13 March 2009 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-05-17T19:11:06Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Camila Carnielli.pdf: 1699139 bytes, checksum: b1052d9900853e8c969d3e1b228cde17 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-06-14T13:57:00Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Camila Carnielli.pdf: 1699139 bytes, checksum: b1052d9900853e8c969d3e1b228cde17 (MD5) / Made available in DSpace on 2016-06-14T13:57:00Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Camila Carnielli.pdf: 1699139 bytes, checksum: b1052d9900853e8c969d3e1b228cde17 (MD5) / A identificação de fontes para material particulado tem sido um tema de crescente interesse em todo o mundo para auxiliar a gestão da qualidade do ar. Esta classe de estudos é convencionalmente baseada no uso de modelos receptores, que identificam e quantificam as fontes responsáveis a partir da concentração do contaminante no receptor. Existe uma variedade de modelos receptores disponíveis na literatura, este trabalho compara os resultados dos modelos receptores balanço químico de massa (BQM) e fatoração de matriz positiva (FMP) para o banco de dados de PM2,5, da região de Brighton, Colorado, com o intuito de investigar as dificuldades na utilização de cada modelo, bem como suas vantagens e desvantagens. Inicialmente, já é conhecido que o modelo BQM tem a desvantagem de necessitar dos perfis das fontes, determinados experimentalmente, para ser aplicado e também tem limitações quando as fontes envolvidas são similares. Já o modelo FMP não requer os perfis de fontes, mas tem a desvantagem de precisar de elevada quantidade amostral da concentração do contaminante no receptor. Os resultados mostraram, baseados nas medidas de performance que os dois modelos foram aptos para reproduzir os dados do receptor com ajustes aceitáveis. Todavia, resultados diferentes se ajustaram a medidas de performance. O modelo BQM, utilizou 9 tipos de fontes e o modelo FMP encontrou apenas 6 tipos de fontes. Constatou-se com isso que o modelo FMP tem dificuldades em modelar fontes que aparecem ocasionalmente. As fontes sulfato de amônio, solos, veículos a diesel e nitrato de amônio tiverem boas correlações nos resultados dos dois modelos de contribuições de fontes. Os perfis de fontes utilizados no modelo BQM e resultados do modelo FMP que mais se assimilaram foram das fontes nitrato de amônio, solos, sulfato de amônio e combustão de madeira e ou/ veículos desregulados. Verificou-se no modelo FMP que as espécies não características de determinadas fontes aparecem nos resultados dos perfis das fontes, o que torna-se ainda mais complexo a identificação das fontes, requerendo elevado conhecimento sobre a composição de inúmeras fontes. / The identification of sources of particulate matter has been a topic of growing interest throughout the world to assist the air quality management. This class of studies is conventionally based on the use of receptor models, which identify and quantify the sources responsible from the concentration of the contaminant in the receptor. There are a variety of receptor models, this study compares the results of chemical mass balance (CMB) and positive matrix factorization (PMF) models for a database of PM2.5, for the region of Brighton, Colorado, with a view to investigate the difficulties in the use of each model, as well as its advantages and disadvantages. It is known that the CMB model has the disadvantage of requiring source profiles, determined experimentally, to be applied and also has limitations when the sources involved are similar. On the other hand, the PMF model does not require source profiles, it has the disadvantage to require a large amount sample, in receptor. The results showed, based on performance measures that both models were able to reproduce the data of the receptor with reasonable fit. However, different results were adjusted for performance measurements. The CMB model, used 9 types of sources and PMF model found only 6 types of sources, it was noted by that what the PMF model has difficulty in modeling sources that appear occasionally. The sources ammonium sulfate, soil, diesel vehicles and ammonium nitrate have good correlation in the results of the two model of sources apportionment. The source profiles used in the CMB model and results of the PMF model that present more similarities were of the sources ammonium nitrate, soil, ammonium sulfate and combustion of wood and/or smoker vehicles. It was verified what the PMF model does not separate well species in the source profiles, therefore becomes even more complex to identify the sources in the FMP model, requiring considerable knowledge about the composition of many sources. For the database used with similar sources, the lack of confidence in the results based only on receptors models for a final decision on the source apportionment.
74

Identificação das fontes de poluição atmosférica na cidade de São Carlos-SP.

Pozza, Simone Andréa 23 March 2005 (has links)
Made available in DSpace on 2016-06-02T19:56:55Z (GMT). No. of bitstreams: 1 602.pdf: 1642879 bytes, checksum: 1333d1314e1afe8f46d0e15cb14f829e (MD5) Previous issue date: 2005-03-23 / Universidade Federal de Sao Carlos / The quality of the atmospheric air is of great importance for the health of the population. Among the quantifiable aspects of the air quality, one can find the particulate matter (PM) concentration in the atmosphere, whose fine (PM10) and ultra-fine (PM2.5) fractions have been extensively studied, as these particle size fractions are particularly damaging for the human health. The main objective of this work was the identification of emission sources of breathable particulate matter, as well as the quantification of their relative participation in the formation of the air pollution in São Carlos/SP, with the use of the reception model. The experiments used the dichotomous sampler for the collection of the particulate matter. Samples were taken in the receptor site, at the city center, in one year period. Also, the emission profiles of local sources (soil, vehicular emission, road dust re-suspension, sugar cane burning and vegetable burning) were measured. The mass concentration was obtained by weighing the sample filters before and after collection. The filter were then submitted to XRF analysis, and 14 chemical elements were quantified (Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Cu, Zn, Pb). Moreover, carbon detection was carried out by the DIC (dissolved inorganic carbon) and DOC (dissolved organic carbon) techniques. These values were fed to the EPA s CMB8 computer pack that calculates the relative contributions of the sources in the reception site. The results show the seasonal dependence of the sources in São Carlos, with the important presence of the vehicular emissions in the whole year. For the fine fraction, the contribution of the sugar cane burning was significant, in the dry season. In the ultra-fine fraction, an appreciable amount of secondary sulfur was found. The comparison between the source contributions calculated from the results of these work with those calculated utilizing data from the EPA´s SPECIATE library revealed very different profiles, confirming the importance of utilizing local sources in the modeling. / A qualidade do ar respirável é um fator de grande importância na saúde de uma população. Dentre os aspectos analisáveis dessa qualidade, encontra-se a quantidade de material particulado (MP) presente na atmosfera, cuja fração fina (MP10) e a superfina (MP2.5) são o foco de amplos estudos, por serem inaláveis no trato respiratório humano. O principal objetivo deste trabalho é a identificação de fontes emissoras de material particulado respirável, bem como a quantificação de suas participações relativas na formação da poluição na cidade de São Carlos/SP, com o uso do modelo receptor. Os experimentos utilizaram o equipamento dicotômico para a coleta do material particulado. Foram realizados monitoramentos do sítio receptor, localizado no centro da cidade de São Carlos, pelo período de um ano. Também foram determinados os perfis de emissão de fontes locais (solo, emissão veicular, ressuspensão, queimada de cana de açúcar e queimada de vegetação). A concentração mássica foi obtida por gravimetria pesando-se os filtros antes e após a amostragem. Os filtros foram submetidos à análise de elementos traços por XRF, sendo quantificada a presença de 14 elementos químicos (Al, Si, P, S, Cl, K, Ca, Ti, Cr, Mn, Fe, Cu, Zn, Pb). Além disso, foi efetuada a determinação de carbono, por DIC (Carbono Inorgânico Dissolvido) e DOC (Carbono Orgânico Dissolvido). Os resultados foram cruzados através do programa CMB8 e apontam para uma dependência sazonal das fontes emissoras, onde se destacam as fontes relativas ao solo e à emissão veicular. No caso da fração fina, a contribuição da queimada de cana de açúcar é significativa, no período seco. Na fração superfina observou-se a presença muito representativa de enxofre secundário. A comparação da distribuição de fontes entre aquela obtida com resultados desse trabalho com aquela obtida exclusivamente do SPECIATE revelou mudanças significativas no perfil obtido, confirmando a importância da utilização de perfis de fontes obtidas localmente.
75

Avaliação do desempenho de um ciclone stairmand adaptado com bicos injetores de água

Chiabai Junior, João 28 March 2014 (has links)
Made available in DSpace on 2016-06-02T19:56:55Z (GMT). No. of bitstreams: 1 6116.pdf: 1917653 bytes, checksum: 3f3db0875dbff03c8cd1500f9f06d230 (MD5) Previous issue date: 2014-03-28 / Universidade Federal de Sao Carlos / The collection efficiency and costs of implementation and operation are the main factors considered in the use of equipment for the separation of particulate matter in the gas. The cyclone is commonly employed industrially by low costs, however its use is limited due to the low efficiency in collecting particles smaller than 5 &#956;m. The increase of conventional cyclone with nozzles water led to an improvement in its collection efficiency. This work experimentally investigated the performance of a wet cyclone in the removal of phosphate rock with median diameter of 4.66 &#956;m. The cyclone was adapted with 8 water injectors nozzles of range type. The concentrations of particles in the entrance and exit of equipment were obtained by isokinetic sampling. The ratio of the flow of liquid / gas (L/G) was varied from 0.65 to 2.20 L/m3 to 3 different nozzle configurations. The outlet temperature decreased compared to entry with increase of the ratio L/G. Have the relative humidity of the gas increased with increasing L/G. The cyclone dry operating had an average efficiency of 76.7% and the best average efficiency the wet was 85.3%. The fractional collection efficiency was determined only for the operating condition that resulted in the best overall efficiency. The adaptation of the cyclone Stairmand with water injectors nozzles resulted in an improvement of 8.6% in the overall collection efficiency. / A eficiência de coleta e os gastos de implantação e operação são os principais fatores considerados na utilização de equipamentos para a separação de material particulado no gás. O ciclone é comumente empregado industrialmente por apresentar baixos custos, entretanto o seu uso é restrito devido à baixa eficiência na coleta de partículas menores que 5 &#956;m. O incremento do ciclone convencional com bicos injetores de água proporcionou uma melhoria na sua eficiência de coleta. Neste trabalho foi investigado experimentalmente o desempenho de um ciclone úmido na remoção de rocha fosfática com diâmetro mediano de 4,66 &#956;m. Foram instalados 8 bicos injetores de água do tipo leque. As concentrações de particulado na entrada e na saída do equipamento foram obtidas através da amostragem isocinética. Variou-se a relação da vazão de líquido/gás (L/G) de 0,65 a 2,20 L/m3 para 3 diferentes configurações de bicos. A temperatura na saída diminuiu em relação à entrada em função do aumento da razão L/G. Já a umidade relativa do gás aumentou conforme o aumento da razão L/G. O ciclone operando a seco apresentou eficiência média de 76,7% e a melhor eficiência média a úmido foi de 85,3%. Foi determinada a eficiência de coleta fracionária apenas para a condição operacional que resultou na melhor eficiência global. A adaptação do ciclone Stairmand com bicos injetores de água resultou em uma melhoria de 8,6% na eficiência global de coleta.
76

Síntese e caracterização de compósitos multiferroicos de manganita La: Sr e titanatos de Ba e Sr

Paranhos, Rafael Rodrigo Garofalo 18 March 2011 (has links)
Made available in DSpace on 2016-06-02T20:16:48Z (GMT). No. of bitstreams: 1 3948.pdf: 2098241 bytes, checksum: 0b554283c942172b9f364fe518595bcf (MD5) Previous issue date: 2011-03-18 / Universidade Federal de Sao Carlos / In this paper, we seek to prepare composite multiferroics extrinsic whose potential for technological applications, especially in the electronics industry, and the possibility of new phenomena of fundamental scientific interest made the subject multiferroics has attracted attention and efforts of the scientific community. Such composites have in its constitution the combination of ferroelectric barium titanate, strontium titanate in paraelectric and the ferromagnetic lanthanum-strontium manganite. This choice is due to the interesting magnetic properties of manganites and its strong coupling between the magnetic properties, electrical and estrututrais, leading to the occurrence of giant magnetostrição [1]. The ferroelectric chosen has a structure compatible with that of the manganite. Moreover, the possibility of adjusting the ferromagnetic transition temperature of the manganite, through chemical doping could make room for the optimization of their properties at room temperature. The synthesis method chosen was the Pechini chemical route, featuring good conditions of uniformity in their characteristics and the final conformation of the specimen was (0-3) For the characterization of the samples was proposed a protocol starting from the structural characterizations and chemical profiles using X-ray diffraction, microstructural through the electron microscope using a high-resolution physical characterizations of relative density, resistivity, dielectric and ferroelectric properties and, finally, analysis of magnetoelectric coupling. The results that deserve mention are the correct phase formation in composite materials and a good densification of the bodies of evidence, above 90%. We can observe the deterioration of electrical properties in composite materials / Neste trabalho, buscamos preparar compósitos multiferroicos extrínsecos cujo potencial para aplicações tecnológicas, em especial na indústria eletrônica, e a possibilidade de ocorrência de novos fenômenos fundamentais de interesse científico fizeram com que o tema multiferroicos tenha atraído a atenção e os esforços da comunidade científica. Tais compósitos apresentam em sua constituição a combinação do ferroelétrico titanato de bário, do paraelétrico titanato de estrôncio e com o ferromagnético manganita de lantânio-estrôncio. Esta escolha se deve às interessantes propriedades magnéticas das manganitas e seu forte acoplamento entre as propriedades magnéticas, elétricas e estrututrais, levando à ocorrência de magnetostrição gigante [1]. O ferroelétrico escolhido tem uma estrutura compatível com a da manganita. Além disso, a possibilidade do ajuste da temperatura de transição ferromagnética da manganita, através de dopagem química, poderia abrir espaço para a otimização das suas propriedades à temperatura ambiente. O método de síntese escolhido foi a rota química Pechini, por apresentar boas condições de uniformidade em suas características finais e a conformação do corpos de provas foi a (0-3) Para a caracterização das amostras foi proposto um protocolo de caracterizações partindo da estrutural e química, utilizando os perfis de difratometria de raios-X, passando pela microestrutural utilizando um microscópio eletrônico de alta resolução, caracterizações físicas de densidade relativa, resistividade, propriedades dielétricas e ferroelétricas e, finalizando, análise do acoplamento magnetoelétrico. Os resultados que merecem destaque são a correta formação de fase nos materiais compósitos e uma boa densificação dos corpos de provas, acima de 90%. Pode-se observar a deterioração das propriedades elétricas nos materiais compósitos
77

Análise da fonte e composição da poluição atmosférica em diferentes locais da região metropolitana de São Paulo / Analysis of source and composition of air pollution in different locations in the Metropolitan Region of São Paulo

Letícia Ogushi Romeiro Ramires 10 January 2013 (has links)
Grandes cidades, como São Paulo, são afetadas de forma significante pela poluição atmosférica. É de grande importância a caracterização das fontes emissoras da poluição atmosférica, não somente nas regiões centrais, mas também nas regiões periféricas, pois a composição da poluição pode não ser homogênea em toda a extensão da cidade. Neste estudo foram caracterizados os componentes da poluição atmosférica em quatro regiões dentro cidade de São Paulo. Para este fim foram Coletados Material Particulado (PM2.5) durante vinte dias no período de inverno de 2011 e vinte dias durante o período de verão de 2011. O material foi coletado através de filtros de policarbonato com 24 h de exposição, e foi submetido a análises gravimétricas, determinação da concentração de Black Carbon por refletância e determinação da composição elementar por Fluorescência de Raios-X. A identificação das diferentes fontes geradoras de material particulado foi baseada na análise de Componentes Principais (ACP). A variação da concentração da massa do material particulado fino (PM2.5) em g/m3 não teve diferença significativa entre os locais amostrados, mas mostrou diferença entre as estações do ano, sendo maior no período do inverno em todos os locais. A proporção do Black Carbon teve um comportamento diferente da massa. O Black Carbon não variou significantemente entre as estações do ano, porém apresentou diferença entre os locais amostrados, destacando-se no Parque do Ibirapuera e na Zona Leste. Foram encontrados 3 Fatores que explicam 75% da variabilidade. O Fator 1 é constituído pelos elementos Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K e foi atribuído como sendo associado à ressuspensão de solo e emissões veiculares, O Fator 2 é composto por V, P, BC, e S e foi interpretado como sendo representativo de emissões veiculares de combustíveis com alto teor de enxofre. O Fator 3 é 7 associado aos elementos BC e Ni e foi interpretado como sendo produzido por emissões veiculares em geral / Large cities such as São Paulo are significantly affected by air pollution. It is of great importance to characterize the emission sources of air pollution, not only in the central regions of the city of São Paulo, but also in peripheral regions, do to the fact that the composition of pollution may not be homogeneous across the city area. This study shows the Characterized the components of air pollution in four different areas of the metropolitan region of São Paulo. Particulate matter (PM 2.5) was collected during the winter of 2011 and summer of 2011. It was collected 24-h PM2.5 samples, employing gravimetry to determine PM2.5 mass concentrations; reflectance to quantify black carbon concentrations and X-ray fluorescence to characterize elemental composition. A receiver model based on principal component analysis (PCA) was used to identify the involvement of the different sources for the generation of particulate matter. The fine particulate matter (PM2.5) in g/m3 did not differ significantly among the locations. However, the results collected showed differences according the seasons evaluation, being higher in the winter for all regions sampled. The proportion of Black Carbon behaves differently than the mass. It does not vary significantly between the seasons, but between the different regions. The proportion of Black Carbon was higher in Ibirapuera Park and the East Zone. Was found 3 factors explaining 75% of the variability. Factor 1 consists of the elements Ti, V, Mn, Fe, Ni, Pb, P, S Cr e K and was related to crustal emission (soil) and vehicle emissions, Factors 2 consists of the elements V, P, BC, e S and can be related to vehicular emissions of fuels with high sulfur content. Factor 3 consists of the elements BC and Ni was associated to vehicle emission
78

Material particulado, microbiota aérea e perfil de resistência de Staphylococcus aureus em suspensão durante o intra-operatório de cirurgias ortopédicas em um hospital de médio porte de São Carlos, SP

Almeida, Cristiane Leite de 22 January 2010 (has links)
Made available in DSpace on 2016-06-02T19:48:16Z (GMT). No. of bitstreams: 1 2825.pdf: 1262073 bytes, checksum: b2962d5f301de96324cede3691966cb9 (MD5) Previous issue date: 2010-01-22 / The control of surgical site infection, especially during clean is important, especially when exposed bone in orthopedic surgery. A study was conducted exploratory study aimed to assess the impact of particulate matter, air and microbial resistance profile of Staphylococcus aureus in suspension for the intraoperative orthopedic procedures in a medium-sized hospital in São Carlos, SP. In the initial ten samples, the results indicate presence of filamentous fungi in 69% of the samples and 93.75% of the bacterial samples were identified as Gram positive and Gram negative 6.25%. In the 10 samples analyzed in the second stage, the UFC's of bacteria had an average of 97.80%, standard deviation of 51.60%, coefficient of variation of 52.75% and range between 21 and 178. We identified the presence of Staphylococcus aureus, Staphylococcus spp. and Shigella spp. 25%, 75% and 25% of samples, respectively. Held an antibiotic for Staphylococcus aureus isolated from the air in the operating room, and found that the strain had high levels of resistance to most antibiotics used, with sensitivity only two of 15 antimicrobial agents tested. The presence of suspended particles was above the recommended standard for the surgery, suggesting the need for an effective control of air quality. It was observed that during surgery there was a significant increase in suspended particles in accordance with WHO standards and CONAMA. The increase in the number of the surgical team in the room probably generated an increase of suspended particles and hence an increase in microbial range. Of the surgeries performed, one can see that in 70% of the operating room door was closed and 50% with air conditioning was off. In 3 (60%) of surgeries in which the air conditioning was off, we found the incidence of a bacterial genus. / O controle da infecção do sítio cirúrgico, principalmente em cirurgias limpas, é relevante, principalmente quando há exposição óssea, em cirurgias ortopédicas. Foi realizado um estudo exploratório e prospectivo que objetivou verificar a incidência de material particulado, microbiota aérea e perfil de resistência de Staphylococcus aureus em suspensão durante o intra-operatório de cirurgias ortopédicas em um hospital de médio porte de São Carlos, SP. Nas dez amostras iniciais, os resultados demonstraram presença de fungos filamentosos em 69% das amostras e 93,75% das amostras bacterianas foram identificadas como Gram positivas e 6,25% Gram negativas. Nas 10 amostras realizadas na segunda etapa, as UFC s de bactérias apresentaram média de 97,80%, desvio padrão de 51,60%, coeficiente de variação de 52,75% e amplitude entre 21 e 178. Foram identificadas a presença de Staphylococcus aureus, Staphylococcus spp. e Shigella spp. em 25%, 75% e 25% das amostras, respectivamente. Realizou-se um antibiograma para Staphylococcus aureus isolados do ar da sala cirúrgica, e verificou-se que a bactéria apresentou elevados índices de resistência a maioria dos antibióticos utilizados, com sensibilidade apenas a dois dos 15 antimicrobianos testados. A presença de material particulado em suspensão estava acima do padrão recomendado durante o intra-operatório, sugerindo a necessidade de um controle efetivo da qualidade do ar. Observou-se que durante os procedimentos cirúrgicos houve um aumento considerável do material particulado em suspensão, de acordo com padrões da OMS e CONAMA. O aumento no número de pessoas da equipe cirúrgica na sala provavelmente gerou um aumento de material particulado em suspensão e, conseqüentemente, um aumento na variedade microbiana. Das cirurgias realizadas, pode-se verificar que em 70% destas, a porta da sala cirúrgica encontrava-se fechada e 50% estava com ar condicionado desligado. Em 3 (60%) das cirurgias em que o ar condicionado estava desligado, observou-se a incidência de um gênero bacteriano.
79

Monitoramento da qualidade do ar de ambientes internos : bibliotecas.

Ito, Lissandra Xavier 09 April 2007 (has links)
Made available in DSpace on 2016-06-02T19:55:21Z (GMT). No. of bitstreams: 1 TeseLXI.pdf: 2823041 bytes, checksum: 5ff061a459816dac605c27cb8ca844f6 (MD5) Previous issue date: 2007-04-09 / The main objective of this study was to monitor and to characterize the particulate material (PM) with equivalent diameter between 2,5 and 10 µm (PM2,5-10), particulate with equivalent diameter smaller than 2,5 µm (PM2,5), particulate with total suspended particles (TSP), and some pollutant gases (ammonia, chlorine, carbon dioxide, ozone, benzene, carbon monoxide and toluene) presents in the indoor environments of public Libraries. Two libraries located in the city of São Paulo were chosen, the Chemistry Buildings Library of the University of São Paulo (CQ USP), and the Library Monteiro Lobato, and two libraries located in the city of São Carlos, the Library Amadeu Amaral and the Communitarian Library of the Federal University of São Carlos (UFSCar). It was used a Small Volume Sampler (APV) which captured the particles using a glass fibre filter and nuclepore hydrophobic membranes, and a chip monitoring system (CMS) which measured the gases concentrations. The experimental essays were followed in the indoor and outdoor environments of the libraries, working with a flow of 16 L/min and sampling time of 1 hour, once a week, varying in relation to the day of the week and the schedule of sampling. After the collection, analyses of X-Ray Fluorescence (XRF) were done to quantify the chemical elements with atomic number superior of 13 g/mol. The chemical elements found in the particulate material of those indoor environments were: Al, Ca, Fe, Cu, Br, Rb, Cl, K, Ti, V, Sr, and S. The results showed that the particulate concentrations between PM2.5-10 and PM2.5 in the indoor environments of the libraries were always greater than in the outdoor ones. The Libraries located downtown São Paulo and São Carlos (Amadeu Amaral and Monteiro Lobato) presented greater concentrations of indoor particulate in the two fractions, PM2.5 and PM2.5-10, justified by the pollution of vehicles, industries, soil resuspension and burning of sugarcane. / O principal objetivo desse trabalho foi monitorar e caracterizar o material particulado com diâmetro equivalente entre 2,5 e 10 µm (PM2,5-10), o particulado com diâmetro equivalente menor que 2,5 µm (PM2,5), o particulado total em suspensão (PTS) e alguns gases poluentes (amônia, cloro, dióxido de carbono, ozônio, benzeno, monóxido de carbono e tolueno) presentes em ambientes internos de Bibliotecas públicas. Foram escolhidas duas bibliotecas localizadas na cidade de São Paulo, a Biblioteca Conjunto das Químicas da Universidade de São Paulo (CQ USP) e a Biblioteca Infanto Juvenil Monteiro Lobato e duas bibliotecas localizadas na cidade de São Carlos, a Biblioteca Amadeu Amaral e a Biblioteca comunitária da Universidade Federal de São Carlos (UFSCar). Foi utilizado um Amostrador de Pequenos Volumes (APV), que capturou as partículas empregando como meio filtrante um filtro de fibra de vidro e membranas nuclepore hidrofóbicas; e um sistema de monitoramento por chip (CMS), onde foram medidas as concentrações de gases. Os experimentos foram realizados dentro das bibliotecas e no ambiente externo das bibliotecas, trabalhou-se com uma vazão de 16 L/min e tempo de amostragem de 1 hora, 1 vez por semana, variando em relação ao dia da semana e ao horário de amostragem. Após a coleta, foram realizadas análises de Fluorescência de Raios X (XRF) para quantificar os elementos químicos com número atômico acima de 13 g/mol, os elementos químicos que foram encontrados no material particulado desses ambientes internos foram: Al, Ca, Fe, Cu, Br, Rb, Cl, K, Ti, V, Sr e S. Os resultados mostraram que as concentrações de particulados nas faixas PM2,5 e PM2,5-10 no ambiente interno das bibliotecas apresentaram valores sempre maiores no ambiente interno do que no externo. As Bibliotecas localizadas na região central das cidades de São Paulo e São Carlos (Amadeu Amaral e Monteiro Lobato) apresentaram maiores concentrações de particulados internos nas duas faixas de particulados, PM2,5 e PM2,5-10, sendo justificadas pela poluição veicular, indústrias, ressuspensão do solo e queimadas de cana de açúcar.
80

Características temporais da concentração de material particulado na atmosfera da cidade de São Carlos - SP / Time characteristics of the atmospheric particulate matter concentration in the city of São Carlos - SP

Pozza, Simone Andréa 19 March 2009 (has links)
Made available in DSpace on 2016-06-02T19:55:22Z (GMT). No. of bitstreams: 1 2284.pdf: 1534326 bytes, checksum: 966007fdeee77cbfc0f06765fad03d24 (MD5) Previous issue date: 2009-03-19 / Universidade Federal de Sao Carlos / The city of São Carlos, of medium size of São Paulo State, can be considered as representative of the Brazilian Southeast area, with agricultural activities practically equivalent to the industrial ones. As part of that profile, it possesses a series of sources of atmospheric pollution that include a considerable fleet of vehicles, agricultural burns and several industrial emissions. The time evolution of this environmental pollution has been reason of concern, once it can cause damages to the human health and to the environment. The present work studied these time characteristics, specifically for the case of particulate matter (PM) suspended in the atmosphere, from experimental data and through statistical models. The concentrations of PM10, PM2.5 and PM10-2.5 in the city of São Carlos were collected and analyzed. The period of study comprises the years from 1997 to 2006 for PM10 and from 2001 to 2006 for PM2,5 and PM10-2,5. Monthly averages were used for obtaining the models and the 30 (thirty) or 6 (six) final data were used for the validation of the forecast. The selection of the best model was made considering the smallest value of AIC (Akaike Information Criterion), through the successive variation of the parameters. Of the 10 models with smaller value of AIC, was chosen the one of smaller value and other with a smaller number of parameters. In the statistical analysis, the models that did not comply with the requirements of the Shapiro-Wilk tests (normality) and of steadiness were eliminated. In the three cases the model SARIMA represented the groups of studied data better, when compared with the Holt-Winters correlation. The model found for the series of data of PM10, was the SARIMA(1,0,0)×(1,0,1)6. In the second case, the concentration of PM2.5 the best model was the SARIMA(2,1,3)×(1,0,1)6. In the third case, the concentration of PM10-2.5, the best model was the SARIMA(2,0,2)×(1,0,0)6. / A cidade de São Carlos, uma cidade de porte médio do estado de São Paulo, pode ser considerada como representativa da região sudeste brasileira, com atividades agrícolas praticamente equivalente às atividades industriais. Dentro desse perfil, possui uma série de fontes de poluição atmosférica, que incluem uma frota considerável de veículos automotores, queimadas agrícolas e emissões industriais diversas. A evolução temporal desta poluição ambiental tem sido motivo de preocupação, uma vez que pode causar danos à saúde humana e ao meio ambiente. O presente trabalho estudou estas características temporais, especificamente para o caso de material particulado (MP) em suspensão na atmosfera, a partir de dados experimentais e através de modelos estatísticos. Foram coletadas e analisadas as concentrações de MP10, MP2,5 e MP10-2,5 na cidade de São Carlos. O período de estudos compreende os dados de 1997 a 2006 para o MP10 e de 2001 a 2006 para MP2,5 e MP10-2,5. Foram usadas médias mensais para a obtenção dos modelos e os 30 (trinta) ou 6 (seis) dados finais foram usados para a validação da previsão. A seleção do melhor modelo foi feita buscando o menor valor de AIC (Critério de Informação de Akaike), por meio da variação sucessiva dos parâmetros. Dos 10 modelos com menor valor de AIC, foram escolhidos o de menor valor e outros com um menor número de parâmetros. Na análise estatística, ocorreu a eliminação de modelos que não atenderam aos requisitos de testes de Shapiro-Wilk (normalidade) e de estacionariedade. Nos três casos, a comparação com Holt-Winters confirma que os modelos SARIMA representaram melhor os conjuntos de dados estudados. O modelo encontrado para a série de dados de MP10 foi o SARIMA(1,0,0)×(1,0,1)6. No segundo caso, a concentração de MP2,5 o melhor modelo encontrado foi o SARIMA(2,1,3)×(1,0,1)6. No terceiro caso, a concentração de MP10-2,5, o modelo encontrado foi o SARIMA(2,0,2)×(1,0,0)6.

Page generated in 0.1597 seconds