• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 76
  • 18
  • 15
  • 11
  • 8
  • 8
  • 5
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 169
  • 21
  • 20
  • 20
  • 19
  • 19
  • 17
  • 14
  • 14
  • 14
  • 13
  • 12
  • 12
  • 12
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Výzkum nových elektrokeramických struktur pro nové aplikace senzorů / An investigation of novel electroceramic structures for new sensor applications

Nan, Bo Unknown Date (has links)
Piezoelektrické keramické materiály jsou široce používány v mnoha aplikacích a průmyslových odvětvích, nicméně tradiční materiály obvykle obsahují olovo, které je toxické vůči životnímu prostředí. Většina zemí proto zavedla zákony a omezení, které postupně minimalizují spotřebu olova a podporují výzkum v oblasti bezolovnatých kompozic, které by nahradily olověné protějšky. Bezolovnatá piezoelektrická keramika se tak stala žhavým tématem v posledních letech. Nicméně výzkumy na praktické využití bezolovnatých piezoelektrických materiálů jsou jen zřídka publikovány. V této diplomové práci byl vybrán jeden z nadějných kandidátů na piezoelektrickou bezolovnatou keramiku (Ba0.85Ca0.15)(Zr0.1Ti0.9)O3 za účelem zkoumání metody snížení jeho vysoké teploty slinování pomocí dotování uhličitanem lithným, kde syntéza prášku byla připravená pomocí techniky sol-gel. Výsledky byly srovnány s konvenčním práškem syntetizovaným v pevné fázi. Vzorky vyrobené ze sol-gel prášku dopovaného 0.5% hmotn. uhličitanem lithným a slinované při 1300 °C po dobu 2 hodin vykazovaly d33 = 447 ± 9 pC N–1, teplotu Curie 98.7 °C a velikost zrn 7.0 ± 0.3 m. Další důležitou otázkou pro aplikace bezolovnatého piezoelektrického keramického materiálu je jeho výroba v různých konfiguracích. Použitím techniky odlévání pásky a aditivních výrobních postupů byla piezoelektrická keramika zpracována do tří různých konfigurací (2-2, 3-3 a 1-3), aby se překlenula mezera mezi materiálovými vědami a materiálovým inženýrstvím. Pro dolévání pásky byly použity suspenze na bázi oleje a vody. Pro přípravu neslinutých keramických fólií bez trhlin, byly pro odlévání na bázi oleje vyvinuty uhlíkové suspenze s obsahem pevných látek 25% hmotn. a BCZT suspenze s obsahem pevných látek 65% hmotn. Problém práškové hydrolýzy ve vodných suspenzích byl vyřešen povrchovou úpravou prášku Al(H2PO4)3, což umožnilo, aby byly tlusté vrstvy bez trhlin odlety v jednom kroku. Tlusté vrstvy slinované při 1500 °C vykazovaly relativní dielektrickou konstantu 1207, dielektrickou ztrátu 0.018 při 1 kHz, remanentní polarizaci 7.54 µC/cm2 a koercitivní síla intenzity pole (Ec) 0.23 kV/mm při 3 kV/mm. Pro tvarování BCZT v konfiguraci 3-3 a 1-3 byla použita přímá metoda tisknutí inkoustu. Pro správnou úpravu tiskového procesu byla použita inkoustová náplň s viskoelastickým chováním obsahující 41.6% obj. pevných látek BCZT a se zpracovatelskými přísadami (HPMC ~ 2.4% a PEI ~ 0.03%). Vzorky v konfiguraci 3-3, slinované při 1500 °C, vykazovaly nejvyšší dielektrické a piezoelektrické vlastnosti, kde Curieho teplota = 86 °C, tan = 0.021, remanentní polarizace = 4.56 µC/cm2 a d33 = 100 ± 4 pC/N. Vzorky v konfiguraci 1-3 slinované při 1500 °C, které byly smíchány s epoxidem, vykazovaly dielektrickou konstantu 144 a dielektrickou ztrátu 0.035 při 1 kHz. Tato práce popisuje tvarování bezolovnaté piezoelektrické keramiky s vynikajícími vlastnostmi v pokročilých strukturách jako krok k návrhu pro moderní senzorické a energy harvesting aplikace.
162

Kotelny na biomasu / Biomass boiler room

Egerle, Dušan January 2013 (has links)
The aim of this project is heating and warm water preparation for apartment block in Choceň (Pardubice region). Apartment block has three aboveground heated floors and one underground unheated floor. The heat source is gasifying firewood boiler or pellet boiler which is at the same time used for water heating but only in the winter time. The other parts of the year the solar collectors are installed and used for water heating. The heat source is located in detached room with its own access, in boiler room.
163

Vytápění polyfunkčního objektu / Heating of the Polyfunctional Object

Slovák, Zdeněk January 2014 (has links)
This thesis deals with the design of the heating system in a Polyfunctional building. The design is solving heating of a Polyfunctional Object in Kostelec nad Ohří. The building has basement and two floors. The building is heated by means of panel, tubular and floor convector heaters. The source of the heat is located in the boiler room in the basement.
164

Energetická náročnost občanské budovy / Energy performance of a civic building

Kořenková, Veronika January 2022 (has links)
The goal of this thesis is to process three variants of energy performance certificate of the building with different heat sources. The building is in mountain area Bílá in Frýdek-Místek region. The thesis has three parts. First part is focused on literary research of heat pumps. Second, calculation part, describes three proposed heat source solution. First heat source is heat pump, second is pellet boiler and the last one is gas condensing boiler. All three variants are evaluated from the economic and ecological perspective. Last part of the thesis contains three energy performance certificates of the examined building.
165

Heating of an apartment building using renewable energy sources / Heating of an apartment building using renewable energy sources

Kováčová, Nour January 2022 (has links)
Diplomová práce je rozdělena na tří částí. První částí je analýza tématu, cílů a způsobů řešení, která obsahuje i teoretickou část. Druhá část je aplikace tématu na řešeném objektu včetně podrobného výpočtu a návrhu otopné soustavy, přípravy teplé vody, dvou variant alternativních zdrojů tepla a jejich porovnání, které vede k výběru lepšího zdroje tepla. Třetí část je projekt a obsahuje technickou zprávu vybrané varianty a projektovou dokumentaci, která obsahuje všechny potřebné výkresy.
166

Wellness Čeladná / Wellness Čeladná

Kozumplíková, Markéta January 2022 (has links)
The aim of this master thesis is to design a low-energy building for civic amenities, specifically the design of a recreational wellness centre. The building has an L-shaped floor plan with a flat roof and is designed with two above ground and one underground floor. The ground floor will serve as a wellness centre with a swimming pool and saunas. Massages and solariums are proposed on the 2nd floor. Technical facilities are located in the basement. The first part of the thesis is devoted to the architectural and structural design. Structurally, the building is divided into two parts. The part of the administrative facilities and the massage rooms consists of a construction of the character of a transverse wall system made of cut brick blocks and insulated with ETICS. The internal masonry is designed in ceramic ground bricks. Ceiling structures are in the form of continuous reinforced concrete slab. The building is based on footings and waist foundations. The roof of the building is single-skin flat with a gravel. The wellness part is made up of a monolithic diaphragm skeleton with high slenderness columns. The horizontal load-bearing structure in this case again consists of a continuous monolithic reinforced concrete slab. The second part of the thesis deals mainly with the environmental engineering of the buildings. The building will be heated by a pellet boiler and will also use energy from photovoltaic panels. Ventilation in the building is provided by air handling units with heat recovery. The third part of the thesis deals with the assessment of solar gains in the indoor environment of the pool hall. Three variants are proposed with multi-criteria evaluation and the optimal option is selected. The thesis is mainly elaborated in Archicad, Deksoft, MS Excel and Word software.
167

Polymer-silica Hybrids for Separation of CO2 and Catalysis of Organic Reactions

Silva Mojica, Ernesto 15 May 2014 (has links)
No description available.
168

Högtempererat borrhålslager för fjärrvärme / High Temperature Borehole Thermal Energy Storage for District Heating

Hallqvist, Karl January 2014 (has links)
The district heating load is seasonally dependent, with a low load during periods of high ambient temperature. Thermal energy storage (TES) has the potential to shift heating loads from winter to summer, thus reducing cost and environmental impact of District Heat production. In this study, a concept of high temperature borehole thermal energy storage (HT-BTES) together with a pellet heating plant for temperature boost, is presented and evaluated by its technical limitations, its ability to supply heat, its function within the district heating system, as well as its environmental impact and economic viability in Gothenburg, Sweden, a city with access to high quantities of waste heat. The concept has proven potentially environmentally friendly and potentially profitable if its design is balanced to achieve a good enough supply temperature from the HT-BTES. The size of the heat storage, the distance between boreholes and low borehole thermal resistance are key parameters to achieve high temperature. Profitability increases if a location with lower temperature demand, as well as risk of future shortage of supply, can be met. Feasibility also increases if existing pellet heating plant and district heating connection can be used and if lower rate of return on investment can be accepted. Access to HT-BTES in the district heating network enables greater flexibility and availability of production of District Heating, thereby facilitating readjustments to different strategies and policies. However, concerns for the durability of feasible borehole heat exchangers (BHE) exist in high temperature application. / Värmebehovet är starkt säsongsberoende, med låg last under perioder av högre omgivningstemperatur och hög last under perioder av lägre omgivningstemperaturer. I Göteborg finns en stor mängd spillvärme tillgängligt för fjärrvärmeproduktion sommartid när behovet av värme är lågt. Tillgång till säsongsvärmelager möjliggör att fjärrvärmeproduktion flyttas från vinterhalvår till sommarhalvår, vilket kan ge såväl lönsamhet som miljönytta. Borrhålsvärmelager är ett förhållandevis billigt sätt att lagra värme, och innebär att berggrunden värms upp under sommaren genom att varmt vatten flödar i borrhål, för att under vinterhalvåret användas genom att låta kallt vatten flöda i borrhålen och värmas upp. I traditionella borrhålsvärmelager används ofta värmepump för att höja värmelagrets urladdade temperatur, men på grund av höga temperaturkrav för fjärrvärme kan kostnaden för värmepump bli hög. I denna rapport föreslås ett system för att klara av att nå höga temperaturer till en lägre kostnad. Systemet består av ett borrhålsvärmelager anpassat för högre temperaturer (HT-BTES) samt pelletspannor för att spetsa lagrets utgående fluid för att nå hög temperatur. Syftet med rapporten är att undersöka potentialen för detta HT-BTES-system med avseende på dess tekniska begränsningar, förmåga till fjärrvärmeleverans, konsekvenser för fjärrvärmesystemet, samt lönsamhet och miljöpåverkan. För att garantera att inlagringen av värme inte är så stor att priset för inlagrad värme ökar väsentligt, utgår inlagringen från hur mycket värme som kyls bort i fjärrvärmenätet sommartid. I verkligheten finns betydligt mer värme tillgänglig till låg kostnad. När HT-BTES-systemet producerar fjärrvärme, ersätts fjärrvärmeproduktion från andra produktionsenheter, förutsatt att HT-BTES-systemets rörliga kostnader är lägre. I Göteborg ersätts främst naturgas från kraftvärme, men också en del flis. Kostnadsbesparingen beror på differensen för total fjärrvärmeproduktionskostnad med och utan HT-BTES-systemet. Undersökningen visar att besparingen är större om HT-BTES-systemet placeras i ett område där det är möjligt att mata ut fjärrvärme med lägre temperatur. Om urladdning från HT-BTES kan ske med hög temperatur ökar också besparingen. Detta sker om lagrets volym ökar, om avståndet mellan borrhål minskar eller om värmeöverföringen mellan det flödande vattnet i borrhålen och berggrunden ökar. Dessa egenskaper för lagret leder också till minskade koldioxidutsläpp. Storleken på besparingen beror dock i hög grad på hur bränslepriser utvecklas i framtiden. Strategiska fördelar med HT-BTES-systemet inkluderar; minskad miljöpåverkan, robust system med lång teknisk livslängd (för delar av HT-BTES-systemet), samt att inlagring av värme kan ske från många olika produktionsenheter. Dessutom kan positiva bieffekter identifieras. Undersökningen visar att HT-BTES-systemet har god potential att ge lönsamhet och minskad miljöpåverkan, och att anläggning och drift av lagret kan ske utan omfattande lokal miljöpåverkan. Det har också visats att de geologiska förutsättningarna för HT-BTES är goda på många platser i Göteborg, även om lokala förhållanden kan skilja sig åt. För att nå lönsamhet för HT-BTES-systemet krävs en avvägning på utformning av lagret för att nå hög urladdad temperatur utan att investeringskostnaden blir för stor. Undersökningen visar att om anslutning av HT-BTES-systemet kan ske mot befintlig anslutningspunkt eller till befintlig värmepanna kan investeringskostnaden minska och därmed lönsamheten öka. Placering av HT-BTES-systemet i områden med risk för överföringsbegränsningar kan också minska behovet av att förstärka fjärrvärmenätet, och således bidra till att minska de kostnader som förstärkning av nätet innebär. Betydelsefulla parametrar för att nå lönsamhet för HT-BTES-system inkluderar dessutom kostnaden för inlagrad värme liksom vilket vinstkrav som kan accepteras. Tillgång till HT-BTES möjliggör ökad nyttjandegrad och flexibilitet för fjärrvärmeproduktionsenheter, och därmed ökad anpassningsmöjlighet till förändrade förutsättningar på värmemarknaden. Dock återstår att visa att komponenter som klarar de höga temperaturkraven kan tillverkas till acceptabel kostnad.
169

Kondenzační technika a odvody spalin / Condensing technology and flue gas

Müller, Jan January 2014 (has links)
This thesis is developed as a proposal for heating for a primary school and kindergarten in the region of Brno-countryside. For the insulated building, a combination of heating and air-conditioning is proposed. The concept is designed so that the air-conditioning preheats the exterior air and the heating system warms the incoming air to a comfortable temperature. For the required thermal performance, sources of heat (for gas and pellets) and a layout solution for the boiler room is designed. Drainage of combustion products is proposed for both solutions. The project solution is per the extent of the construction permit. The theoretical part is linked with the practical part through the condensation boilers, their function and division, and drainage of combustion products. The experiment for the given topic was conducted on the drainage of combustion products. The pressure loss of the reverse knob was determined in relation to the flow rate of air in the condensation boilers as this loss is essential in assessing the drainage of combustion products.

Page generated in 0.0373 seconds