• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 362
  • 24
  • 10
  • 10
  • 10
  • 10
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 1
  • 1
  • Tagged with
  • 391
  • 321
  • 255
  • 230
  • 121
  • 113
  • 85
  • 51
  • 47
  • 41
  • 41
  • 29
  • 27
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Observação clínica da aplicação de um produto a base de peróxido de hidrogênio a 35% não fotoativado : efeitos na sensibilidade e na alteração de cor /

Machado, Lucas Silveira. January 2010 (has links)
Resumo: O objetivo deste trabalho clínico foi avaliar a sensibilidade e a alteração de cor dos elementos dentais, quando submetidos ao clareamento de consultório, com um produto à base de peróxido de hidrogênio a 35%, sem fotoativação. Fizeram parte dessa pesquisa clínica 22 voluntários.Os fatores em estudo foram Tratamento Clareador em dois níveis (gel experimental a base de peróxido de hidrogênio a 35% e placebo) e Tipo de Dente em dois níveis (incisivos e caninos). Os voluntários tiveram suas hemiarcadas superiores direita e esquerda submetidas ao tratamento placebo ou experimental, caracterizando um delineamento tipo split-mouth, ou de boca dividida. Foram realizadas quatro sessões de clareamento, com uma semana de intervalo entre as sessões. A mensuração da variável alteração da cor foi realizada, pelo método visual, previamente ao início do experimento e após a aplicação dos materiais; e da variável sensibilidade durante e após a aplicação da técnica clareadora. De acordo com os fatores clareamento e sessões de clareamento em estudo; assim como com as variáveis de resposta cor e sensibilidade, foram aplicados os testes não paramétricos do sinal, de Mann-Whitney e de Kruskal-Wallis, ao nível de significância de 5%. Foi observado que após a primeira, segunda e terceira sessões, os dentes foram clareados quando tratados com o agente experimental a base de peróxido de hidrogênio a 35%; para a variável sensibilidade, foi verificado após a terceira e quarta sessões de clareamento com o agente experimental peróxido de hidrogênio a 35%, a presença de sensibilidade estatisticamente superior ao tratamento com o produto placebo, em todos os tempos de avaliação. Concluiu-se que a alteração de cor e a sensibilidade dental foram provocadas pelo gel clareador / Abstract: This clinical research will be evaluating the sensitivity, the alteration and stability colors dental, on patients when submitted to in-office dental bleaching with 35% HP, without light-activation sources. According to pre-established criteria, 20 patients will be selected. The factors will be Bleaching Procedures in two levels (experimental gel based on 35% HP and placebo) and Teeth in two levels (incisors and canines). According to a randomly draw, the volunteers will be theirs superior hemiarches, right and left, submitted to placebo treatment or experimental treatment, characterizing a split-mouth design. It will be carry out four sessions of the bleaching procedures with a one week break between sessions. The response variables analysed at each session will be: Dental Color, measured previously and immediately after application of the materials and removal of absolute isolation; and Sensitivity, measured during and till 24 hours after the aplication of the bleaching procedures. The results obtained will be submitted to appropriate Statistical analysis. It was observed that after the first, second and third sessions, the teeth were bleached when treated with the experimental agent on hydrogen peroxide 35%. The variable sensitivity was observed after the third and fourth sessions of bleaching agent experimental hydrogen peroxide 35%. It was concluded that the color change and tooth sensitivity are varied depending on the whitening gel / Orientador: Renato Herman Sundfeld / Coorientador: Eduardo Passos Rocha / Banca: Marcelo Giannini / Banca: Rodrigo Sversut de Alexandre / Mestre
102

Rugosidade e microdureza do esmalte clareado com peróxido de carbamida a 10% e escovado com diferentes dentifrícios: estudo in vitro e in situ

Melo, Carolina França de Medeiros January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:40Z (GMT). No. of bitstreams: 2 000422269-0.pdf: 1482550 bytes, checksum: 2ab1328a5dd68b64d8200aabbf0ab2c1 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This in vitro study evaluated the combined effect of 10% carbamide peroxide with three toothpastes used during bleaching treatment on microhardness and surface roughness of enamel. Fragments (4mm x 4mm x 2mm) were obtained from 18 human teeth. The initial roughness and microhardness were measured. The fragments were randomly divided into six groups (n=12): G1 - 10% carbamide peroxide (PC10) and brushing with regular toothpaste (R); G2 - PC10 and whitening toothpaste (W); G3 – PC10 and whitening toothpaste with baking soda and peroxide (BS); G4 – Placebo (PLA)+R; G5 (PLA+W); G6 (PLA+BS). The fragments were daily exposed to each treatment agent for six hours and the brushing procedures were performed for seven seconds, with a brushing force of 200g and 250 cycles per minute. The groups were kept in artificial saliva at 37°C until the next cycle of treatment agent and brushing procedures. After 21 days, the final roughness and microhardness measurements of each fragment were obtained. According to paired Student’s t-test, there was a significantly decrease in microhardness for all groups (p<0. 05). The final roughness was statistically higher than the initial roughness only in the group treated with G6 (p=0. 001).According to ANOVA GLM and Bonferroni tests, PLA presented a significantly higher roughness than PC10, and toothpaste BS presented a statistically higher roughness (p<0. 05) than W. Toothpaste R did not differ statistically from W and BS (p>0. 05). For PC10, the toothpastes did not differ among them in relation to microhardness (p>0. 05). According to paired Student’s t-test, toothpastes R and W were statistically different for both treatments. The association of PC10 with toothpastes R, W and BS for 21 days did not significantly alter the enamel surface roughness, but there was a significant decrease in the enamel microhardness. / Foram realizados dois estudos, in vitro e in situ para avaliar a rugosidade e microdureza do esmalte clareado com peróxido de carbamida a 10% (PC10) e escovado com dentifrícios. Fragmentos de esmalte foram obtidos a partir de dentes humanos. A rugosidade e microdureza iniciais foram medidas. Para o estudo in vitro, estes fragmentos foram divididos em seis grupos (n=12): G1 – PC10 e escovado com um dentifrício regular (R); G2 – PC10 escovado com dentifrício clareador (W); G3 – PC10 escovado com dentifrício clareador com bicarbonato de sódio e peróxido de cálcio (BS); G4 – Placebo (PLA) + R; G5 – PLA+W; G6 – PLA+BS. Os fragmentos foram expostos a cada agente de tratamento por 6 horas e escovados com força de 200g por 250 ciclos/minuto durante 7 segundos. Os grupos foram armazenados à 37°C em saliva artificial. Após 21 dias foram feitas medidas finais de rugosidade e microdureza de cada fragmento. Para o estudo in situ, dois grupos de cinco voluntários receberam o PC10 e o PLA por 21 dias em diferentes sequências e em dois períodos distintos, utilizando um estudo crossover 2X3. Foram obtidos 180 fragmentos e distribuídos em 20 dispositivos removíveis intraorais (DRI). Cada DRI recebeu nove fragmentos divididos em três trios, nos quais foram escovados com três dentifrícios: R (Colgate máxima proteção anticáries) no centro do palato; W (Colgate total 12 whiteness gel) e BS (Colgate whitening Oxygen Bubbles) nas regiões direita e esquerda dos pré-molares, respectivamente. Ambos agentes de tratamentos foram aplicados por 8 horas durante a noite. Após as escovações, os voluntários usaram os DRI por, aproximadamente, 16 horas/dia. Para o segundo período (21 dias), novos DRI foram distribuídos e os voluntários receberam o agente de tratamento diferente daquele utilizado no primeiro período.As medidas de rugosidade e microdureza foram medidas antes e após cada período. De acordo com o teste t-Student pareado, in vitro, houve uma diminuição significante da microdureza para todos os grupos (p<0,05) e a rugosidade final foi estatisticamente maior que a final apenas para o G6 (p=0. 001). In situ, a rugosidade final foi estatisticamente maior que a inicial e a microdureza final foi estatisticamente menor que a inicial (p<0,05). De acordo com a ANOVA GLM, apenas os dentifrícios foram significantes (p=0,037) para a rugosidade superficial. No estudo in vitro, o agente PLA apresentou um aumento significativamente maior que o PC10 na microdureza do esmalte, enquanto que para o teste de Bonferroni, o dentifrício BS apresentou uma rugosidade significativamente maior que o W (p<0,05). Em relação a microdureza, com o PC10, os dentifrícios não diferiram entre si. Pode-se concluir, para o estudo in vitro, que a associação do PC10 com dentifrícios R, W e BS por 21 dias não alterou significativamente a rugosidade, mas diminuiu significativamente a microdureza do esmalte. Para o estudo in situ, a associação do peróxido de carbamida a 10% com os dentifrícios BS, W e R causou um aumento significativo na rugosidade e uma diminuição significativa na microdureza superficial do esmalte. O dentifrício BS apresentou a maior rugosidade, seguido por W e R.
103

Estudo in vitro da variação do pH de agentes clareadores e seu efeito sobre o desgaste e rugosidade superficial do esmalte bovino após escovação simulada / Variation of pH bleaching gels, wear and roughness of bovine enamel after tooth brushing abrasion test.

Ana Carolina Trentino 20 May 2011 (has links)
Este estudo in vitro avaliou a variação do pH de géis clareadores à base de peróxido de hidrogênio de diferentes concentrações e seu efeito sobre o esmalte bovino submetido à escovação simulada. Fragmentos de esmalte de dentes bovinos com 1,5cm x 0,5cm x 0,4cm, receberam o tratamento clareador e a escovação em uma metade, ficando a outra como controle; foram divididos aleatoriamente em nove grupos (n=10): G1 = controle; G2 = Whiteness HP 35% - 3 sessões (3x15); G3 = Whiteness HP 35% - 3 sessões (1x45); G4 = Lase Peroxide 35% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G5 = Lase Peroxide 25% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G6 = Lase Peroxide 15% - 1 sessão (4x730) + ativação com luz híbrida LED/Laser; G7 = Whitegold Office 35% - 3 sessões (1x45); G8 = Whiteness HP Blue Calcium 35% - 3 sessões (1x40); G9 = Whiteness HP Blue Calcium 20% - 3 sessões (1x50). A rugosidade aritmética (Ra) inicial, após clareamento e após escovação foi determinada pela média (µm) de 3 leituras com o rugosímetro Hommel Tester T 1000. Os valores de pH foram determinados pelo peagômetro digital Sentron Model 1001 nos tempos inicial e final independente do número de aplicações ou de sessões. Os espécimes foram armazenados em saliva artificial por 7 dias, submetidos à 100.000 ciclos de escovação simulada. Após 24 horas o desgaste superficial foi determinado (µm) novamente com o rugosímetro Hommel Tester T1000. Os dados da análise de pH foram submetidos a ANOVA um critério e teste de Tukey (p<0,05) com diferenças estatísticas. O teste de Kruskal Wallis e Dunn (p<0,05) aplicado sobre a variação da rugosidade e desgaste apontou diferenças estatísticas entre os grupos. Os géis clareadores apresentaram uma tendência de diminuição dos valores de pH do tempo inicial para o tempo final. Os géis clareadores apresentaram um tendência de diminuição dos valores de pH do tempo inicial para o tempo final, assim como os géis com valores de pH mais próximos dos valores ácidos tendem a levar a superfície do esmalte à uma maior susceptibilidade ao aumento da rugosidade e desgaste superficial, quando submetido à escovação simulada. / This in vitro study evaluated the variation of the pH of bleaching gels, roughness and the wear on bovine enamel, after various in office bleaching protocols and brushing. Ninety fragments of enamel, measuring 15mm x 5mm, were randomly divided into nine groups (n=10) according to bleaching procedure: G1: control; G2: 35% hydrogen peroxide (HP) (Whiteness HP, FGM) 3x15, 3 sessions with one week between each; G3: 35% HP (Whiteness HP, FGM) 1x45, in 3 sessions; G4: 35% HP (Lase Peroxide, DMC) + hybrid light (HL) (LED/Diode laser, Whitening Lase II, DMC Equipments), 4x730 (6 of HL activation), in 1 session; G5: 25% HP (Lase Peroxide II, DMC) + HL, 4x730 (6 of HL activation), in 1 session; G6: 15% HP (Lase Peroxide Light, DMC) 4x730 (6 of HL activation), in 1 session; G7: 35% HP (Whitegold Office, Dentsply) 3x15, in 3 sessions; G8: 35% HP (Whiteness HP Blue Calcium, FGM) 1x40, in 3 sessions; G9: 20% HP (Whiteness HP Blue Calcium, FGM) 1x50, in 3 sessions. The pH values were determined using a pH meter (Sentron Model 1001, Sentron) during the initial and final gel application times. The surface roughness (Ra) was evaluated with a rugosimeter (Hommel Tester T 1000) before and after bleaching, and after brushing (100,000 strokes). The rugosimeter was used to evaluate wear surface after 24 hours brushing. The data were submitted to one-way ANOVA and Tukey tests for pH values, Kruskall Wallis and Dunns test in relation to wear and surface roughness (p<0.05). It could be concluded that the pH values tended to decrease from the initial to final bleaching. After tooth brushing, bleaching procedures with highly acidic products provided a significant increase in enamel wear and surface roughness.
104

Avaliação clínica da efetividade de géis clareadores de baixa concentração no clareamento em consultório de dentes polpados, com e sem o emprego de fonte de luz híbrida e condicionamento ácido prévio do esmalte

Martha Beteghelli Michielin 08 May 2015 (has links)
O objetivo deste estudo clínico randomizado duplo cego boca-dividida foi avaliar, in vivo, a efetividade do condicionamento ácido prévio do esmalte e de géis clareadores a base de peróxido de hidrogênio (PH) de baixa concentração, associados a fontes de luz híbrida (LH), tendo como variáveis de reposta: sensibilidade dental, fluxo sanguíneo pulpar, grau de mudança e estabilidade de cor ao longo de 6 meses. Trinta e seis voluntários que se encaixaram nos critérios de inclusão e exclusão foram selecionados e randomizados em 3 grupos (n=12), de acordo com o protocolo clareador a ser utilizado. Dentro de cada grupo, um dos hemiarcos foi aleatoriamente selecionado para a realização do condicionamento ácido do esmalte, previamente a aplicação do gel clareador. Os géis que compunham os três protocolos clareadores foram: PH a 10% (experimental) associado a LH a base de LED violeta + laser de diodo (experimental); PH a 15% associado a LH a base de LED azul + laser de diodo; e PH a 35% sem ativação com fonte de luz. A sensibilidade foi avaliada com a escala VAS; a fluxometria pulpar, com o sistema Laser Doppler; e a cor pelo cálculo do ?E via espectrofotômetro. Os dados foram tratados pela análise de variância de medidas repetidas (ANOVA), Tukey e teste de Friedman (p<0,05). Com relação à sensibilidade, foram encontradas diferenças significativas na interação tempo e grupo, mas não com relação ao ácido. Quanto à vascularização pulpar, o efeito de grupo não foi rejeitado, sendo o grupo de PH a 35% o que apresentou as menores medianas para as variações percentuais, porém os efeitos de ácido e tempo não foram significativos. Quanto à cor, diferenças significantes foram encontradas entre os grupos, mas não com relação ao uso do ácido, sendo o PH a 35% o que promoveu maior aumento do ?E. Conclui-se assim que o condicionamento ácido não foi capaz de favorecer a efetividade do clareamento em função do grau de mudança e estabilidade de cor, bem como não aumentou a sensibilidade e o fluxo sanguíneo da polpa dental. A concentração dos agentes clareadores foi determinante para o grau de mudança de cor e demonstrou influenciar a sensibilidade e o fluxo sanguíneo pulpar. / The aim of this double blind split-mouth randomized clinical study was to evaluate, in vivo, the effectiveness of prior acid etching on enamel and low concentration bleaching gels based on hydrogen peroxide (HP) associated with hybrid light (HL) sources, having as response variables: dental sensitivity, dental pulp vascularization and degree of color change and stability over 6 months. Thirty-six volunteers in agreement with the inclusion and exclusion criteria were selected and randomly divided into 3 groups (n = 12) according to the bleaching protocol to be used. Within each group, one of the sides was randomly selected for the execution of acid etching prior to the gel application. The three bleaching gels were: 10% HP (experimental) associated with HL-based violet LED/laser (experimental); 15% HP associated with HL-based blue LED/laser; and 35% HP without light activation. Sensitivity was evaluated with the VAS scale; pulp flowmetry by the use of the Laser Doppler system; and efficacy was evaluated by calculating the ?E via a spectrophotometer. Data were analyzed by analysis of variance for repeated measures (ANOVA), Tukeys and Friedman tests (p<0.05). Regarding sensitivity, significant differences were found in the interaction between the application time and group but not regarding etching. For dental pulp flowmetry, the group effect was not rejected, where the 35% HP showed the lowest medians for the percentile variations, but the effects of etching and time were not significant. For color, significant differences were found between the groups, but not between the sides with and without acid etching, where the 35% HP gel promoted the highest increase in ?E. It is therefore concluded that the etching was not able to favor the effectiveness of whitening due to color variation and stability, as well as not increasing sensitivity or pulp blood flow. The concentration of bleaching agents determined the degree of color change and influenced the sensitivity and blood flow of the dental pulp.
105

Desenvolvimento e validação de método indicador de estabilidade de formulações farmacêuticas de uso tópico contendo peróxido de benzoíla / Development and validation of indicator stability method of pharmaceutical formulations for topical use containing benzoyl peroxide

Fernando Lino Dias 17 March 2014 (has links)
O peróxido de benzoíla, produto de interação do peróxido de sódio com cloreto de benzoíla, é um poderoso agente antibacteriano de amplo espectro com ação queratolítica, comedolítica, descamativa, antipruriginosa e desengordurante, além de também ser um potente agente oxidante, que reage com materiais orgânicos rompendo as membranas celulares de inúmeros agentes patogênicos. Em virtude de suas características, o peróxido de benzoíla é utilizado como produto de eleição como adjuvante no tratamento de sarnas (dermodicidoses), desqueratinizações, complexo seborréico, piodermites, foliculites superficiais, impetigo e piodermite de dobras. Neste projeto é abordado o desenvolvimento e validação de um método indicador de estabilidade do fármaco peróxido de benzoíla, cujo objetivo é ser utilizado como ferramenta para a identificação e doseamento de maneira precisa e exata dos produtos de degradação desconhecidos formados, a partir de variados ambientes de acondicionamento estressantes, nos quais o medicamento possa ser eventualmente submetido durante o seu prazo de vida de prateleira. O método analítico proposto foi validado conforme os requerimentos vigentes da ANVISA e se baseia na técnica de cromatografia líquida de alta eficiência (CLAE) para doseamento do princípio ativo e seus produtos de degradação, em uma única corrida analítica, o que permite determiná-los simultaneamente, e portanto é adequado para utilização durante o estudo de estabilidade acelerado e de longa duração, além de metodologia indicadora de estabilidade.Durante o estudo de degradação forçada foram geradas uma série de \"picos\" desconhecidos inerentes ao fármaco, especialmente nas condições de aquecimento, hidrólise em meios ácido e alcalino, e fotólise. Entretanto, durante o estudo foram investigados aqueles originados a partir desta última, uma vez a posologia da preparação medicamentosa estudada é via tópica, pois se trata da forma farmacêutica semi-sólida gel. Para avaliação dos produtos de degradação gerados durante a fotólise foi utilizada a cromatografia líquida com detecção por espectrometria de massas, onde o fármaco foi ionizado na forma positiva (+) através da técnica Electrospray ionization (ESI+), a qual permitiu a proposição da estrutura molecular da substância gerada, a partir da provável perda do grupamento alquil ou aldeído, justificando assim a razão massa carga 199,1 u.m.a. / Benzoyl peroxide , the produced by interaction of sodium peroxide with Benzoyl chloride is a powerful antibacterial agent with keratolytic , comedolytic , scaly , antipruritic and degreasing action, as well as being a powerful oxidizing agent that reacts with organic materials disrupting the membrane cell of many pathogens agents . Due to its characteristics, benzoyl peroxide is used as the main choice in the treatment of scabies, seborrhea complex, pyoderma, superficial folliculitis, impetigo and pyoderma folds. This project addresses the development and validation of an indicator stability method for benzoyl peroxide, which is intended to be used as a tool for the identification and accurate and preciously determination of unknown degradation products formed from various stressful environments, in which the API may eventually be submitted during the period of shelf life. The proposed analytical method was validated according to the applicable/current requirements of ANVISA and it is based on the technique of high performance liquid chromatography (HPLC) assay for the active ingredient and its degradation products in a single analytical run, allowing dosing them simultaneously, and thus it is suitable for use during accelerated and long term stability studies and as stability indicating method. During the forced degradation study many unknown \"peaks\" inherent to drug were generate, especially under heating, acid and alkaline hydrolysis, beyond photolysis conditions. However, throughout this study were investigated that obtained from the photolysis, since the sample preparation are applied topically because it is semi - solid dosage gel form. To evaluate the degradation products generated during photolysis were used liquid chromatography with detection by mass spectrometry, where the drug was ionized in the positive (+) form by technical Electrospray ionization (ESI+) technique, which allowed the proposition of the molecular structure substance generated from the probable loss of the alkyl or aldehyde grouping , thus justifying the mass/charge ratio 199.1 amu.
106

Processo de peroxidação de açúcar tipo VHP na produção de açúcar refinado: implicações químicas, tecnológicas e microbiológicas / Clarification of the type VHP sugar syrup by hydrogen peroxide: chemical implications, technological and microbiological

Juliana Lorenz Mandro 28 June 2016 (has links)
Atualmente, o setor sucroenergético está se tornando cada vez mais competitivo, o que de fato é incentivado, principalmente, pela representativa demanda e exigências do mercado externo. Ao se analisar a produção do açúcar refinado, podem-se encontrar barreiras para a sua ampla aceitação nacional e internacional devido ao método de clarificação empregado, uma vez que este é realizado através da queima de enxofre elementar em câmaras de combustão. O uso do sulfito acima dos limites permitidos pode ocasionar potenciais problemas de saúde pública. Neste sentido, o Brasil tem realizado estudos sobre a adoção de novas tecnologias para a substituição da sulfitação, sem alteração da qualidade do açúcar refinado a ser produzido. Partindo deste pressuposto, fez-se a avaliação do uso do peróxido de hidrogênio (H2O2) em solução comercial (35% v/v) como reagente alternativo ao dióxido de enxofre para obtenção de açúcar refinado com menor cor ICUMSA. Para isso, na calda de açúcar do tipo VHP, foram testadas doses distintas de peróxido de hidrogênio, aliadas a diferentes pH e temperaturas frente a um Delineamento composto central composto central, permitindo a otimização e o acompanhamento das transformações decorrentes do processo. Com isso, obteve-se como melhores condições o pH 7,5 e 10, temperaturas entre 50 e 70 °C e dosagens entre 500 e 797,6 ppm de H2O2. A análise a partir da cinética química da peroxidação da calda permitiu observar maiores reduções da cor ICUMSA em geral nos tempos de 50 a 75 minutos e nos 30 primeiros minutos para os pontos extremos de pH, temperatura e dose de H2O2. A degradação de sacarose não foi um fator expressivo quanto ao tempo, pois a mesma na maioria dos casos foi degradada nos 5 primeiros minutos e após esse tempo se mantinha sem muitas alterações, sendo mais vulnerável as condições de pH 3,32 e 11,68, altas temperaturas (83,6 °C) e máxima dosagem H2O2 (1000 ppm) aplicados. Além de favorecer a redução da cor ICUMSA da calda, o H2O2 também se mostrou como um bom agente antimicrobiano, principalmente quando associado às altas temperaturas. Agindo com maior intensidade na diminuição da carga bactériana do que na diminuição da carga fungica. A rede neural artificial (RNA) mostrou um bom ajuste e indicou a variável °Brix (teor de sólidos solúveis) como a que apresentou maior influência na redução da cor ICUMSA e a variável tempo a que menor influenciou na redução de cor. / Nowadays, the sugar-energy industry is becoming increasingly competitive, which indeed is encouraged mainly by representative demand and requirements of foreign markets. When analyzing the production of refined sugar can be found barriers to their widespread international acceptance due to the clarification method employed, since this is performed by burning elemental sulfur in combustion boilers. The use of sulfite above the permitted limits can result in potential public health problems. In this regard, Brazil has conducted studies on the adoption of new technologies to replace the sulfite, without changing the quality of the produced refined sugar. On that basis, it was done the evaluation of the use of hydrogen peroxide (H2O2) in commercial solution (35% v/v) as an alternative reagent to sulfur dioxide to obtain refined sugar with less ICUMSA color. For this the sugar liquor VHP different doses of hydrogen peroxide were tested, together with different pH and temperatures outside a central composite design, enabling optimization and monitoring of changes resulting from the process. Thus there was obtained as the best pH conditions 7.5 to 10, temperatures between 50 and 70 °C and dosages between 500 and 797.6 ppm H2O2. The analysis from the chemical kinetics of the peroxidation of the liquor has observed greater reductions in ICUMSA color in general in the time of 50 minutes to 75 minutes and in the first 25 minutes to the extremes of pH, temperature and H2O2 dose. As for sucrose degradation was not a significant factor, since it in most cases was first degraded within 5 minutes and after this time remained without many changes, being more vulnerable conditions (3.32 and 11.68), high temperatures (83.6 °C) and H2O2 maximum dosage (1000 ppm) applied. In addition to further reduce color ICUMSA H2O2 Liquor also showed such a good antimicrobial agent, particularly when combined with high temperatures. Acting with more intensity in the decrease of bacteria than the reduction of fungi. The artificial neural network (ANN) showed good fit and indicated the variable ° Brix (soluble solids) as the one with the greatest influence in reducing the ICUMSA color and variable time that less influenced the color reduction.
107

Cinética do Processo de degradação do herbicida atrazina pelo processo avançado de oxidação H2O2 UVC

Felix de Lima, Valmir 31 January 2010 (has links)
Made available in DSpace on 2014-06-12T18:05:52Z (GMT). No. of bitstreams: 2 arquivo2904_1.pdf: 1897752 bytes, checksum: 433cb1f7a73aaf3cc4486da83b3a4293 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2010 / Neste trabalho, o Processo de Oxidação Avançado H2O2-UV foi utilizado para degradar o herbicida atrazina em solução aquosa. Devido à sinergia encontrada entre as possíveis rotas de oxidação sofrida pelo herbicida atrazina e seus metabólitos que absorvem radiação UV, os processos de fotólise direta a 254 nm e peroxidação foram também desenvolvidos. O reator utilizado foi de geometria anular, especialmente projetado para o estudo cinético operado dentro de um ciclo continuo e em batelada. Modelos para as distribuições de energia radiante no fotorreator e concentração do herbicida atrazina e oxidantes foram desenvolvidos utilizando os princípios básicos dos fenômenos dos transportes. A taxa local volumétrica de absorção de fótons, LVRPA, foi modelada com base no modelo de incidência. Os modelos para as taxas de reação de degradação do herbicida atrazina, de seus metabólitos e do peróxido hidrogênio foram segundo a abordagem mecanicista. Todavia, para a fotólise direta, foi utilizado um modelo fenomenológico para uma reação fotoquímica. Os modelos apresentaram boa representação dos dados para a faixa de concentração inicial do herbicida atrazina testada. A taxa de reação é uma função da LVPRA da concentração do herbicida atrazina e seus metabólitos e da concentração do peróxido de hidrogênio. O processo de fotólise direta resultou ser uma função direta do rendimento quântico, da LVRPA e da concentração do herbicida atrazina e seus metabólitos. A rotina de otimização Runge-Kutta associada com o método Box (minimização de funções) foi utilizada para estimar os parâmetros cinéticos. Os valores cinéticos estimados foram: atz, UV f = 2,99 x 10-2 mol Einstein-1, m = 1,90 x 10-2, n = 5,04 x 10-1
108

Efecto in vitro del peróxido de hidrógeno al 35% sobre el sellado marginal de restauraciones con resina compuesta de nanopartículas

Anaya Huaman, Erika Pamela, Cusma Malca, Fiorella Catherine January 2016 (has links)
Debido a la popularidad del uso de los agentes de blanqueamiento, hoy en día existe una gran preocupación a nivel profesional sobre los efectos que se puedan dar luego de su aplicación sobre los tejidos dentarios y materiales dentales de restauración, evaluar el efecto in vitro del peróxido de hidrógeno al 35% sobre el sellado marginal de restauraciones con resina compuesta de nanopartículas, se utilizó 146 premorales humanos los cuales fueron extraídos debido a un tratamiento ortodóntico. En estos se realizó una cavidad clase V en la cara vestibular y posteriormente fueron restauradas con resina compuesta de nanopartículas. Se asignó aleatoriamente 73 unidades de estudio a cada grupo. El primer grupo fue el grupo control al que no se le aplicó el peróxido de hidrogeno al 35 %. El segundo grupo fue el grupo experimental al cual se le realizó 4 aplicaciones, de 8 minutos cada una, de peróxido de hidrógeno al 35%, en la cara vestibular de todos los premolares restaurados. Luego todas las piezas dentarias fueron sometidas en una solución acuosa de azul de metileno al 1% como indicador de microfiltración tras lo cual se procedió al corte transversal y análisis bajo microscopio electrónico, con un aumento de 10x para posteriormente asignar valores de microfiltración según el grado de penetración de la tinción en la interfase diente-restauración. Los datos obtenidos serán tabulados en una ficha de recolección de datos, con la prueba Z para diferencia de proporciones, leída al 95% de confiabilidad, el análisis de los resultados obtenidos en este estudio, mediante la prueba Z, indica que existen diferencias estadísticamente significativas en los valores de microfiltración entre el grupo con tratamiento blanqueador y el grupo sin tratamiento blanqueador y se concluyó que el peróxido de hidrógeno al 35% afecta negativamente el sellado de las restauraciones de resina compuesta. / Tesis
109

Detoxificación de aguas residuales provenientes de plantas metalúrgicas

Silvestre Mira, María 18 December 2015 (has links)
[EN] The aim of this PhD is to study the search alternatives treatments, based on solar photocatalysis, for detoxification of effluents from metal finishing industry. This type of wastewater contains cyanides and metals, namely copper, what results in a high toxicity and hence, they cannot be discharged without a previous treatment. Different advanced oxidation processes have been studied at laboratory scale using synthetic effluents containing 100 mg/L of free cyanide: solar photocatalysis with TiO2, oxidation with hydrogen peroxide or persulfate and photo-Fenton-like processes with iron, manganese, zonc, silver, cobalt, chromium or copper (in all coses at a pH above 12, which is compatible with the presence of cyanide in solution ). Those treatments involving silver, cobalt and copper were very efficient under the studied experimental conditions. As real effluents contains important amounts of copper, further experiments were performed using this metal. The possible interferences of different anions with the treatment involving copper and peroxide were investigated: carbonate, sulphate, fluoride and nitrate. Its presence has been demenstrated to inhibit the removal of free cyanide, although detoxification is finally achieved. Experiments were scaled up to a pilot plant able to treat 4 liters of real wastewater from a metal finishing factory. The were submitted to the following processes: photocatalysis with titanium dioxide, photo-Fenton-like processes with iron or copper. The efficiency of hydrogen peroxide in the presence of metals already present in the effluent was tested and then, the process was scaled up to 50 L. During the process, removal of total and free cyanide, copper concentration, variation of TC, pH, conductivity and toxicity (inhibition of respiration of activated sludge and luminescence of Vibrio fischeri) were monitored. Assessment of the analyzed parameters showed that best results were reached in a photo-Fenton-like process with copperA complete removal of cyanide is achieved, involving detoxification of the effluent. Final precipitation of copper allows its removal from the effluent by filtration. / [ES] La presente Tesis Doctoral pretende buscar nuevas alternativas basadas en la fotocatálisis solar a los tratamientos existentes para la detoxificación de las aguas procedentes de la industria metalúrgica. Estas aguas contienen cianuro y metales como el cobre que les confiere elevadas toxicidades y hace imprescindible su tratamiento previo a vertido. Se han ensayado diferentes técnicas de oxidación avanzada a escala de laboratorio con aguas modelo que contenían 100 mg/L de cianuro libre: fotocatálisis solar con TiO2, tratamientos con peróxido de hidrógeno y persulfato como oxidantes y procesos tipo foto-Fenton con hierro, manganeso, cinc, plata, cobalto, cromo y cobre (en todos estos casos se ha respetado el pH mayor a 12 para evitar problemas con el cianuro presente en disolución). Los tratamientos con plata, cobalto y cobre se mostraron muy eficaces en las condiciones de trabajo. Puesto que las aguas reales contenían cantidades considerables de cobre como residuo del proceso de fabricación, se dio mayor relevancia a los tratamientos empleando este metal. Se han determinado posibles interferencias en el tratamiento con cobre y peróxido de hidrógeno de aniones presentes comunmente en las aguas: carbonatos, sulfatos, fluoruros y nitratos. Su presencia ralentiza el proceso de eliminación del cianuro libre, aunque finalmente se consigue la detoxificación de las muestras. Se realizaron estudios en planta piloto de 4 litros de aguas reales de empresa de recubrientos metálicos con los siguientes procesos: fotocatálisis con dióxido de titanio, procesos tipo foto-Fenton con cobre o hierro y adición de peróxido de hidrógeno sin más catalizadores. Se determinó la eficacia de la adición de peróxido de hidrógeno al actuar con los metales presentes en las aguas y se escaló el proceso a la planta de 50 litros ubicada en una empresa del sector. Durante el tratamiento se midió la degradación del cianuro libre y total, variación en la concentración del cobre, la evolución del TC, pH, conductividad y toxicidad (inhibición de fangos activos y de la luminiscencia de Vibrio fischeri). El análisis global de los tratamientos aplicados determina que los mejores resultados se obtienen mediante el proceso tipo foto-Fenton con cobre (metal ya presente en las aguas). Se consigue la total degradación del cianuro, con la consiguiente detoxificación de las aguas. La precipitación final del cobre favorece además su eliminación del efluente mediante aplicación de un filtro prensa. / [CAT] La present Tesi Doctoral pretén buscar noves alternatives basades en la fotocatálisis solar als tractaments existents per a la detoxificació de les aigües procedents de la indústria metal·lúrgica. Estes aigües contenen cianur i metalls com el coure que els conferix elevades toxicitats i fa imprescindible el seu tractament previ a l'abocament. S'han assajat diferents tècniques d'oxidació avançada a escala de laboratori amb aigües model que contenien 100 mg/L de cianur lliure: fotocatálisis solar amb TiO2, tractaments amb peròxid d' hidrogen i persulfat com a oxidants i processos tipus foto-Fenton amb ferro, manganés, zinc, plata, cobalt, crom i coure (en tots estos casos s'ha respectat el pH major a 12 per a evitar problemes amb el cianur present en dissolució). Els tractaments amb plata, cobalt i coure es van mostrar molt eficaços en les condicions de treball. Ja que les aigües reals contenien quantitats considerables de coure com a residu del procés es va donar major rellevància als tractaments emprant este metall. S'han determinat possibles interferències en el tractament amb coure i peròxid d' hidrogen d' anions presents comunmente en les aigües: carbonats, sulfats, fluorurs i nitrats. La seua presència ralentitza el procés d'eliminació del cianur lliure, encara que finalment s'aconseguix la detoxificación de les mostres. Es van realitzar estudis en planta pilot de 4 litres d' aigües reals d'empresa de recubrients metàl·lics amb els processos següents: fotocatálisis amb diòxid de titani, processos tipus foto-Fenton amb coure o ferro i addició de peròxid d' hidrogen sense més catalitzadors. Es va determinar l' eficàcia de l' addició de peròxid d' hidrogen al actuar amb els metalls presents en les aigües i es va escalar el procés a la planta de 50 litres ubicada en una empresa del sector. Durant el tractament es va mesurar la degradació del cianur lliure i total, variació en la concentració del coure, l' evolució del TC, pH, conductivitat i toxicitat (inhibició de fangs actius i de la lluminiscència de Vibrio fischeri). L' anàlisi global dels tractaments aplicats determina que els millors resultats s'obtenen per mitjà del procés tipus foto-Fenton amb coure (metall ja present en les aigües). S' aconseguix la total degradació del cianur, amb la consegüent detoxificación de les aigües. La precipitació final del coure afavorix a més la seua eliminació de l' efluent per mitjà d'aplicació d'un filtre premsa. / Silvestre Mira, M. (2015). Detoxificación de aguas residuales provenientes de plantas metalúrgicas [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/58988 / TESIS
110

Clareamento dental interno: efeito de diferentes sistemas na microdureza e micromorfologia superficial da dentina bovina / Effect of different bleaching systems on the microhardness and ultrastructure of bovine dentin

Guerisoli, Laise Daniela Carrasco 07 January 2008 (has links)
Este estudo teve como objetivos: 01.Avaliar ex vivo o efeito de diferentes sistemas clareadores na microdureza dentinária em dentes bovinos submetidos ao clareamento dental interno. 02.Avaliar ex vivo o efeito de diferentes sistemas clareadores na morfologia superficial da dentina bovina. Fragmentos de 4 x 4mm, contendo esmalte e dentina, foram obtidos de coroas de incisivos bovinos extraídos. Os espécimes foram submetidos ao clareamento dental interno com peróxido de hidrogênio a 35% e peróxido de carbamida a 37% utilizando sistemas convencionais (Opalescence Endo® and Whiteness Super Endo®) e fotoativados (Opalescence Xtra® and Whiteness HP Maxx®). Os controles foram tratados com perborato de sódio misturado com peróxido de hidrogênio a 10% ou nenhum tratamento foi realizado. A microdureza dentinária foi mensurada antes e após os tratamentos clareadores, e os valores de dureza Knoop (KHN) foram submetidos à análise estatística (two-way ANOVA, Tukey\'s port-test). Os espécimes foram observados e fotografados sob microscópio eletrônico de varredura e avaliados com relação às alterações morfológicas da superfície da dentina. Houve uma redução significante na microdureza dentinária para todos os grupos testados quando comparados aos grupos controles. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) e Whiteness Super Endo® (-16.97 ± 6.55 KHN) foram semelhantes estatisticamente. O grupo do perborato de sódio misturado com peróxido de hidrogênio 10% (2.10 ± 8.58 KHN) e o grupo sem tratamento clareador (-2.71 ± 2.40 KHN) também foram estatisticamente semelhantes entre si. Ocorreu uma grande variação no padrão de alterações da morfologia superficial da dentina com os sistemas clareadores utilizados. Todos os produtos testados apresentaram redução significativa da microdureza dentinária, exceto o grupo de perborato de sódio misturado com peróxido de hidrogênio a 10%. Ambos, pH e oxidação do peróxido de hidrogênio apresentam o papel de alterar a estrutura da dentina durante o clareamento interno. A utilização de produtos alcalinos com um tempo reduzido de aplicação (técnicas fotoativadas) pode diminuir as alterações morfológicas na dentina. / The aim of this study was: 01. To evaluate in vitro the effect of different in-office bleaching systems on the surface morphology of bovine dentin. 02. To evaluate ex vivo the effect of different bleaching systems on the microhardness of bovine dentine. Tooth fragments measuring 4 x 4mm, containing enamel and dentin, were obtained from the crowns of extracted bovine incisors. Samples were submitted to simulated intracoronal bleaching techniques with 35% hydrogen peroxide and 37% carbamide peroxide using conventional (Opalescence Endo® and Whiteness Super Endo®) and light activated systems (Opalescence Xtra® and Whiteness HP Maxx®). Controls were treated either with sodium perborate mixed with 10% hydrogen peroxide or no bleaching agent. Dentine microhardness values were measured before and after bleaching procedures, recorded as KHN (Knoop Hardness Number), and the differences between them analyzed (two-way ANOVA, Tukey\'s port-test). The samples were observed under SEM and the recorded images were evaluated for topographic alterations. Significant reductions of dentine microhardness were observed for all treatments when compared to the control groups. Opalescence Xtra® (-11.36 ± 8.14 KHN), Opalescence Endo® (-13.71 ± 8.02 KHN), Whiteness HP Maxx® (-15.18 ± 9.58 KHN) and Whiteness Super Endo® (- 16.97 ± 6.55 KHN) presented similar differences. The walking bleach technique (2.10 ± 8.58 KHN) and the untreated groups (-2.71 ± 2.40 KHN) were statistically alike.The ultrastructural alterations of dentin observed in this study varied greatly between groups, according to the products used. Apparently, higher pH products associated to in-office techniques yielded to better maintenance of dentin ultrastructure. The in-office products tested in the present study caused a significant reduction in dentine microhardness. The walking bleach technique did not affect dentine microhardness. Both low pH and hydrogen peroxide oxidation play a role in altering the ultrastructure of dentin during internal dental bleaching. The use of alkaline products with reduced time of application (in-office techniques) may decrease such morphological alterations.

Page generated in 0.0588 seconds