• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 69
  • Tagged with
  • 69
  • 69
  • 33
  • 28
  • 26
  • 21
  • 15
  • 14
  • 13
  • 13
  • 13
  • 12
  • 10
  • 10
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo do escoamento no duto de admissão de um veículo de Fórmula SAE. / Analysis of the flow in the intake manifold of a Formula SAE vehicle.

Provase, Ivan Sanches 29 April 2015 (has links)
Motivado pela ocorrência de instabilidade do motor do veículo de Fórmula SAE da equipe Poli Racing da Escola Politécnica da Universidade de São Paulo quando operando em altas rotações, o escoamento no conduto de admissão, mais especificamente no último conduto antes do flange do motor, conhecido como runner, foi então analisado. A suspeita de que o descolamento do escoamento da parede na região interna da curvatura fosse a causa da instabilidade do motor foi então estudada de duas maneiras: um estudo numérico e outro experimental. O estudo numérico se inicia pela caracterização do escoamento real e desenvolvimento de hipóteses simplificadores e considerações sobre os pontos mais relevantes do escoamento. Em seguida, uma malha de elementos é construída no computador com auxílio de um programa de CFD. Ressalta-se que sua geometria reproduz a geometria interna do duto de interesse (runner). Posteriormente, a mesma é simulada utilizando um modelo de duas equações (SST k-w), obtendo-se assim o perfil de pressão ao longo da região interna e externa da parede do runner.O estudo experimental se inicia pela construção do runner em prototipagem rápida, mantendo sua geometria fiel à geometria do runner utilizado no veículo de referência, adaptando a esse, tomadas de pressão ao longo da sua seção meridional. Ele é então montado em laboratório e as pressões nas diversas tomadas de pressão são então medidas para diferentes valores de vazão.Os resultados acima obtidos são então comparados com as referências bibliográficas relevantes.De maneira geral, tanto os resultados numéricos como os resultados experimentais estão de acordo com as referências bibliográficas, indicando que até valores do número de Reynolds iguais a aproximadamente 210000 (o que corresponde para as condições de temperatura e pressão do ar de admissão durante a operação do motor, a uma velocidade média no runner de cerca de 80 m/s) não ocorre descolamento na região interna da curvatura do runner. / Motivated by the occurrence of instability of the engine of the Formula SAE vehicle of the Poli Racing team from the Polytechnic School of University of São Paulo when operating at high engine speeds, the flow in the intake manifold, more specifically in the last duct before the engine flange, known as runner, became focus of deeper analysis. The suspicion that the detachment of the flow from the wall in the inner region of curvature was the cause of engine instability was studied in two approaches: a numerical study and an experimental study. The numerical study begins by characterizing the real flow and development of simplifying assumptions and considerations on the most relevant points of the flow. Then, a mesh is built into the computer with the aid of a CFD program. Its geometry is equal to the internal geometry of the studied duct (runner). Subsequently, the mesh is simulated using a two equations model (SST k-w) and a pressure profile in the inner and outer wall is calculated. The experimental study begins with the construction of the runner using rapid prototyping, keeping its geometry equal to the geometry of the runner used in the reference vehicle, but adapting to this, pressure taps along the inner and outer wall of the curvature. It is then assembled in the laboratory and the pressure in different pressure taps are measured for different flow rates.The above results are then compared with the relevant bibliographic references.In general, both the numerical results and the experimental results are in agreement with the references indicating that up to Reynolds numbers values equal to approximately 210 000 (which considering the air temperature and pressure while engine is operating, corresponds to an average speed in the runner around 80 m/s) does not occur any detachment in the inner region of curvature of the runner.
12

Análise de circuitos de descarga de ar pressurizado para ventilação de equipamentos em vôo.

Ronaldo Queiroz Macedo 31 October 2006 (has links)
Sistemas que operam com dissipação de calor e estão instalados na região pressurizada de uma aeronave podem requerer ventilação forçada, sendo necessário rejeitar este calor para fora da aeronave. A rejeição deste calor ée feita por sistema dedicado de ventilação, descarregando ar pressurizado através de alguma válvula controlada pelo sistema de pressurização, ou por uma tubulação com restrição de vazão, como venturi ou placa de orifício. Neste caso, a vazão deve ser limitada de tal forma que não prejudique a operação do sistema de pressurização, mas deve ser suficiente para ventilar os componentes que dissipam calor. Simulações de escoamento de ar pressurizado de aeronaves em estrangulamentos devem ser feitos considerando compressibilidade e a possibilidade de ocorrência de ondas de choque (escoamento sônico). Neste trabalho ée apresentado um modelo para cálculo de perda de carga em venturi e placa de orifícios, incluindo em condições de formação de onda de choque. O principal objetivo ée simular o sistema de ventilação de um Chiller, que ée composto por dutos, curvas, venturi e placa de orifícios, e estimar a vazão do sistema de ventilação em vôo, considerando compressibilidade e ondas de choque. Os resultados do modelo são próximos de resultados de ensaios em vôo, comparações feitas para diversas altitudes.
13

Análise da distribuição de velocidade e pressão nos dutos de ar condicionado de uma aeronave regional.

Luis Carlos Pavan 15 April 2009 (has links)
O presente trabalho trata da simulação do escoamento interno dos dutos de distribuição de ar condicionado de aeronaves regionais, buscando compreender e analisar a influência da configuração dos orifícios de insuflamento de ar na distribuição de velocidade e pressão no interior dos dutos e através dos orifícios. Utiliza-se o ambiente computacional FLOWMASTER, para o desenvolvimento dos modelos e análises comparativas. Foram simuladas seis configurações distintas de orifícios de insuflamento e comparadas quanto ao balanceamento e perda de carga gerada no duto. Os resultados mostraram que as configurações com orifícios de diâmetros maiores e mais espaçados apresentam o melhor balanceamento, no entanto, também apresentam as maiores perda de carga. Desta forma é possível escolher um valor ótimo para o diâmetro dos orifícios de insuflamento estabelecendo um compromisso entre o balanceamento e a perda de carga no duto.
14

Perda de carga em conectores iniciais da irrigação localizada / Local head loss on initial trickle irrigation connectors

Vilaça, Francisco Nogueira 23 May 2012 (has links)
Sistemas de irrigação geralmente são dimensionados negligenciando-se os cálculos das perdas localizadas de carga, o que muitas vezes causa desbalanço hidráulico deste sistema. A irrigação localizada possui muitas peças especiais para as quais, muitas vezes, não existem equações matemáticas que possibilitem o cálculo destas perdas. Este trabalho teve como objetivo o ajuste de equações que permitam o cálculo da perda localizada de carga para a passagem direta e outra para a passagem lateral, causada pela presença de conectores iniciais de linha. A perda de carga na passagem direta é causada pela área da protrusão do conector internamente à tubulação e a perda de carga na passagem lateral é causada pela mudança no perfil de escoamento da água ao passar pelo conector. Para as duas situações a perda localizada no conector foi obtida por diferença entre a perda distribuída de carga no tubo mais conector e a perda distribuída de carga no tubo sem conector. Foram utilizados 5 conectores em 5 diâmetros de tubulação de polietileno e 3 diâmetros de tubulação de PVC. Foi utilizada análise dimensional para o desenvolvimento das equações que para a passagem direta apresentou um coeficiente de determinação de 97,27% e para a passagem lateral o coeficiente de determinação foi de 96,26%. As duas equações desenvolvidas apresentaram um coeficiente ótimo de desempenho, sendo seu uso indicado para os limites testados neste trabalho. / Irrigation systems are generally dimensioned neglecting the calculation of the local head loss which often causes a hydraulic disbalance of this system. There are many special components on a trickle irrigation system to which there are not mathematical equations that allow the calculation of these head losses. This study aimed the adjustment of one equation for calculating the local head losses to the direct passage and one for the lateral passage, caused by the presence of initial connectors on the lateral line. The local head loss on the direct passage is caused by the protrusion area of the connector inside the pipe and the local head loss on the lateral passage is caused by the change in the flow cross-section, when water passes through the connector. For both situations the local head loss on the connector was obtained by the difference between the local head loss on the pipe plus the connectors and the local head loss on the pipe without the connectors. There were used 5 connectors in 5 diameters polyethylene pipes and 3 diameters PVC pipes. Dimensional analysis was used to develop the equations that for the direct passage presented a determination coefficient of 97,27% and for the lateral passage the determination coefficient was 96,26%. The two equations developed showed a good coefficient of performance, and its use is indicated for the limits tested in this study.
15

Escoamento em regime turbulento aplicado à Irrigação localizada com microtubos / Turbulent flow theory applied to localized irrigation (microtubs)

Souza, Wanderley de Jesus 03 February 2009 (has links)
Realizou se a presente pesquisa, visando investigar e apresentar um método alternativo de irrigação localizada, com o qual se obtivesse baixo custo e nível tecnológico comparável aos métodos existentes no mercado. Para tanto, desenvolveu-se os modelos matemáticos UNIVERSAL e WSBOTREL, para dimensionamento de microtubos sob regime de escoamento turbulento, onde se inclui as perdas de carga no microtubo, perda de carga localizada e por energia de velocidade na saída do microtubo, sendo que os mesmos foram utilizados no desenvolvimento de um software em planilha de Excel, para projetar linhas laterais com microtubos de comprimentos iguais e variáveis. Os modelos foram avaliados com o dimensionamento de uma linha lateral de irrigação, e tiveram ótimos desempenhos, tendo em vista que os dados coletados proporcionaram vazão média próxima da vazão de projeto, com coeficiente de determinação acima de 98%, excelente uniformidade de distribuição, baixo erro médio absoluto e coeficiente de variação de vazão. Avaliou-se o comportamento da água sob diferentes pressões e temperaturas, e verificou-se que a variação da vazão foi quase nula para uma diferença de temperatura de 3,00 Kelvins. O modelo WSBOTREL foi empregado para projetar um sistema de irrigação, com a proposta de utilizar fertirrigação em mudas de laranja cultivadas em estufa. O sistema ficou sob avaliação durante 160 dias, sendo que no final do ciclo, não foi observado entupimento dos emissores, e, as plantas tiveram alturas e diâmetros do caule iguais às plantas irrigadas de maneira tradicional com mangueiras, conforme procedimento adotado pela empresa, com vantagem de economizar mão de obra e solução utilizada na fertirrigação. Dessa forma, pode-se dizer que o sistema de irrigação com microtubos em regime de escoamento turbulento se mostrou tecnicamente viável para utilização. / The present work aims to investigate an alternative method of localized irrigation, with low cost and technological level comparable to nowadays equipments on the market. To do so, it has developed the mathematical models UNIVERSAL and WSBOTREL, for calculating microtubs diameter and length that would work under turbulent flow, where it is considered: head loss in the microtub and localized head loss at extremities. It was development software on a spreadsheet Excel, to design laterals lines with microtubs of similar and variable length. The models were evaluated for calculating the lateral line of irrigation systems, presenting great performance: collected data showed average discharge close to projected discharge, with coefficient of determination of 98%, excellent uniformity of distribution, low mean absolute error and variation coefficient of discharge. It was evaluated the behavior of emitters under different pressures and water temperatures. It was found that the discharge of variation was almost zero for a temperature difference of 3 degree Kelvin. The WSBOTREL model was used to design an commercial irrigation system, with the objective of making use of fertirrigation in nursery citrus plants (greenhouse). The system was under evaluation during 160 days. At the end of the growing cycle, it wasn´t observed clogging of emitters, and plants presented similar high and diameter of stem compare to the traditional irrigation method (hoses) according to the procedure adopted by the company, with advantage to reduce hand work and solution used in fertirrigation. The irrigation system with microtub under turbulent zone of flow was technically feasible to use.
16

Avaliação do tipo de material filtrante no comportamento hidráulico de filtros rápidos de camada profunda no tratamento de águas de abastecimento. / Evaluation of filter media in the hydraulic behaviour of rapid gravity depth bed filters used in drinking water treatment.

Brinck, Nádia Cristina Pires 08 July 2009 (has links)
Neste projeto de pesquisa avaliou-se a etapa de filtração no processo de tratamento de água para abastecimento público. Para isto, foi utilizado um sistema de filtração piloto composto por quatro filtros rápidos por gravidade de camada profunda. Os filtros piloto foram alimentados com água decantada da Estação de Tratamento de Água Rio Grande, e operados com taxa de filtração de 500 m3/m2/dia. A concepção dos filtros variou em termos de material filtrante (areia e antracito), diâmetro dos grãos e altura do leito. Os filtros foram avaliados em termos de turbidez, contagem de partículas, evolução de perda de carga e velocidade ascensional de água de lavagem. Na Etapa 1, operando-se filtros de areia e antracito com diferentes diâmetros, o filtro de antracito com 1,3 mm de diâmetro e 120 cm de altura apresentou melhor comportamento no tocante aos parâmetros avaliados. Na etapa 2, comparando-se filtros de areia e de antracito com mesmo diâmetro (1,3 mm) e altura de leito (120 cm), mais uma vez o filtro de antracito foi superior. Acredita-se que os índices físicos justifiquem esse comportamento. Na Etapa 3, conclui-se que o aumento de altura de leito dos filtros de areia (1,3 mm) e antracito (1,3 mm) de 120 cm para 160 cm foi benéfico para ambos os materiais filtrantes em termos de qualidade do efluente, mas muito mais significativo para o antracito, e não se observou alteração de comportamento no tocante à evolução de perda de carga. Com o ensaio de fluidificação e expansão do leito filtrante, conclui-se que, considerando-se o mesmo tempo de duração da lavagem e a mesma expansão do leito, o filtro de antracito possibilitou a utilização de menor velocidade ascensional de água de lavagem, que representa grande economia com relação aos custos do sistema de lavagem. Assim, em todos os aspectos estudados, o uso de antracito (1,3 mm) como material filtrante para filtros rápidos por gravidade de camada profunda se mostrou mais vantajoso. / This project researched the filtration stage in the water treatment process for public use. The research used a pilot filtration system based on four rapid gravity depth bed filters, with a filtration rate of 500m3/m2/dia. The water used in the experiment came from sedimentation tank of the Rio Grande water treatment facility. During the experimental phase the filters were loaded with different depth, used different filter media (sand and anthracite) and used grain with different effective size. The filters were evaluated in terms of turbidity, particle count, head loss and superficial velocity of backwashing water. In the first part of the study, when analyzing the results of filters loaded to a depth of 120 cm using both sand and anthracite with different size, the anthracite filter with effective size of 1.3 mm was the one with the best results. In the second part of the study, when comparing anthracite and sand with same the effective size, the anthracite also presented better results. Finally when increasing the depth of the filter, both sand and anthracite filters showed improved performance in terms of effluent quality, but anthracite filters kept outperforming sand filters. In both case, there were no evidences of changing in the head loss development. When performing fluidization and expansion experiments, considering the same backwashing cycle time and expansion of filter media, the anthracite filter allowed lower superficial velocity which represents relevant economies in the washing system costs. Therefore the use of anthracite (1.3mm) as a filter medium for rapid gravity depth bed filters is recommended.
17

[en] TRANSPORTATION COEFFICIENTS FOR FLAT AND FINNED TRIANGULAR DUCTS / [pt] COEFICIENTES DE TRANSPORTE EM DUTOS TRIANGULARES LISOS E PINADOS

SERGIO LEAL BRAGA 21 September 2012 (has links)
[pt] Experiências foram realizadas para se determinar coeficientes de transferência de calor e fatores de atrito para escoamento em dutos cujas seções transversais têm a forma de triângulos isósceles. Dois dutos foram usados; um tinha um ângulo de vértice igual a 120 graus e o outro 60 graus. As experiências foram realizadas utilizando-se trocadores de calor de dutos triangulares. Os fluidos foram ar e água. Coeficientes médios de transferência de calor foram determinados através da medida dis coeficientes globais de transferência de calor dos trocadores. No caso do duto de 120 graus, as paredes dos triângulos isósceles eram lisas. Foram estudados escoamentos laminares e turbulentos. Para o duto de 60 graus, duas paredes pinadas. A finalidade dos pinos foi aumentar a área de troca de calor. Nesse caso (60 graus) apenas escoamento turbulento foi estudado. Para os dutos com paredes lisas, foi possível se obter a dependência dos coeficientes de troca de calor dos dutos com o número de Prandtl. Para se atingir condições totalmente desenvolvidas, os trocadores de calor, tinham um comprimento de entrada de aproximadamente 35 diâmetros hidráulicos. As condições de contorno térmicas consistiram de temperatura uniforme nas paredes iguais dos dutos, sendo a terceira parede isolada. Os dutos triangulares dos trocadores de calor consistiram de duas paredes metálicas e uma parede de material menos condutor. Os resultados são apresentados sob formas adimensionais. Números de Nusselt e fatores de atrito como funções dos números de Reynolds. / [en] Experiments were performed to determine heat transfer coefficients and friction factors for flows in ducts whose cross sections have the shape of isosceles triangles. Two ducts were used; one with an apex angle equal to 120 degrees and the other 60 degrees. The experiments were performed by utilizing triangular duct heat exchangers. The fluids were air and water. Average heat transfer coefficients of the heat exchangers. In the case of the 120 degrees duct, the walls of the isosceles triangles were smooth. Laminar and turbulent flows were studied. For the 60 degrees duct, two situations were considered; one with smooth walls and the other with two pinned walls. The purpose of the pins was to increase the heat transfer area. In this case (60 degrees) only turbulent flow was studied. For the ducts with smooth walls, it was possible to obtain the dependence of the duct heat transfer coefficients with prandtl number. To attain the duct heat transfer coefficients with Prandtl number. To attain fully developed conditions, the heat exchangers had a starting length of approximately 35 hydraulic diameters. The thermal boundary conditions consisted of uniform temperature on the two equal walls of the duct, the third wall being insulated. The triangular ducts of the heat exchangers consisted of two metallic walls and of lesser conduction material. The results are presented in dimensionless forms. Nusselt numbers and friction factors as functions of Reynolds Numbers.
18

[en] RELIABILITY ANALYSIS OF LARGE GENERATING SYSTEMS CONSIDERING DATA UNCERTAINTIES / [pt] CONFIABILIDADE DE SISTEMAS DE GERAÇÃO DE GRANDE PORTE NA PRESENÇA DE INCERTEZAS NOS DADOS

JORGE COELHO 05 July 2006 (has links)
[pt] Este trabalho apresenta um método geral e prático, baseado em técnicas de convolução discreta, para avaliar o valor esperado e a variância dos índices de freqüência e duração (FeD) da perda de carga de um sistema de geração. O método proposto modela sem qualquer restrição unidades geradoras com estados operativos de capacidade reduzida simultaneamente com todos possíveis estados de carga. O valor esperado e a variância dos índices de freqüência e duração da perda de carga são calculados, tratando as taxas de transição entre estados de geração e os picos de carga previstos como variáveis aleatórias. Técnicas de agregação são utilizadas para modelar as incertezas das disponibilidades da capacidade de geração das unidades hidráulicas. Sob este aspecto, os índices de confiabilidade são também variáveis aleatórias. A determinação da expansão da capacidade de geração na presença de incertezas é a proposta sob um novo enfoque. Este método avalia limites de confiança ( ou percentis) não só para os índices de perda de carga, mas também para os índices de Freqüência e Duração da falha. Assim, a expansão da capacidade de geração é reutilizada utilizando os percentis dos índices de risco em vez de se utilizar apenas seus valores médios. O método FeD proposto é utilizado para avaliar o impacto das incertezas nos parâmetros dos geradores e da carga, em sistemas típicos da geração, incluindo o Sistema Teste da confiabilidade do IEEE e uma configuração planejada para 1991 do Sistema Sul-Sudeste Brasileiro. / [en] This work presents a practical and general method base on discrete convolution techniques for evaluating the expectation and variance of the frequency and duration (FeD) reliability indices, for a single area system. The proposed method models simultaneously and without any restriction, derated generating capacity generation units with all possible load levels. The expectation and variance of Frequency and duration reability indices are evaluated based on discrete convolution, treating the the generating unit transition rates and forecast peak loads as random variables. Clustering techniques are used to model the incertainties in the output capacities of hydraulic units. Under this interpretation, the reliability indices are also random variables. The generation capacity expansion problem under uncertainties, for a single-area system, is addressed from a new point of view. This method determines confidence limits (or percenties) not only for the loss of load indices but also for the frequency and duration failure indices. The generating capacity expansion is then calculated through risk indices percenties instead of the usual expected values. The proposed FeD method is then used for evaluating the impact of load and generating parameter uncertainties on typical systems including the IEEE Reliability Test System, and the Brazlian South/Southeastern Generating System.
19

Perda de carga em tubulações comerciais conduzindo água residuária de avicultura / Head loss in the commercial pipelines conducting poultry raising wastewater

Zinato, Cristiano Egnaldo 29 August 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-20T15:50:51Z No. of bitstreams: 1 texto completo.pdf: 1265725 bytes, checksum: b031e35d4a63a48d73579d55f531b6e4 (MD5) / Made available in DSpace on 2017-02-20T15:50:51Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1265725 bytes, checksum: b031e35d4a63a48d73579d55f531b6e4 (MD5) Previous issue date: 2003-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho foi desenvolvido com os propósitos de avaliar a perda de carga em tubulações comerciais de ferro galvanizado, aço zincado e PVC conduzindo água residuária de avicultura (ARA), determinar equações que a estimem em função da vazão, do diâmetro e da concentração de sólidos totais, bem como levantar as características reológicas da ARA. Os resultados possibilitaram concluir que: (a) a ARA foi classificada reologicamente como plástico de Bingham; (b) as viscosidades de todas as concentrações analisadas apresentaram-se menores que a viscosidade da água; (c) a massa específica das partículas em suspensão na ARA foi de 1,84 g cm -3 e o seu diâmetro menor que 1 mm; (d) a perda de carga da ARA para as concentrações de sólidos totais estudadas foi menor do que para a água limpa, diminuindo até a concentração de 0,4600 dag L -1 e voltando a crescer daí até a concentração de 2,8941 dag L -1 ; (e) os modelos empíricos apresentaram melhores resultados do que o modelo que estima o fator de atrito f. O modelo que melhor estimou a perda de carga foi o de Hazen-Williams modificado, para quaisquer vazões, concentrações de sólidos totais, tipos de materiais e diâmetros de tubos, recomendando-se seu uso em detrimento dos outros modelos. Este modelo subestima, em média, a perda de carga, e apresenta, em geral, os menores erros médios e desvios padrão, justificando seu melhor ajuste, quando comparados aos demais; (f) na prática a variável ST (concentração de sólidos totais) pode ser suprimida da equação para a faixa de ST estudada, considerando-se desprezível o seu efeito no cálculo da perda de carga pelo modelo de Hazen-Williams modificado; (g) uma vez que a perda de carga medida na água limpa foi maior de 9,7 % a 20,8 % para a tubulação de ferro galvanizado de 130,30 mm, de 9,7 % a 32,0 % para a tubulação de aço zincado de 99,83 mm, e de 11,0 % a 26,3 % para a tubulação de PVC de 79,90 mm, comparadas às estimadas pelo modelo de Hazen-Williams modificado para água residuária de avicultura, recomenda-se utilizar equações que determinem a perda de carga para a água limpa no dimensionamento de sistemas hidráulicos que ocasionalmente transportem água residuária de avicultura com as características apresentadas neste trabalho. / The objective of this study was to evaluate the head loss in commercial pipelines made of galvanized iron, zinc-coated steel and PVC conducting poultry raising wastewater (PW), to determine the equations that would estimate this loss as a function of flow rate, pipe diameter and the concentration of the total solids, as well as to determine the rheological characteristics found in poultry raising wastewater (PW), as well as to determine the rheological characteristics of this wastewater. Based on the results, the conclusions were drawn as follows. (a) PW was rheologically classified as Bingham plastic. (b) The viscosity of all analyzed concentrations were lower than that the viscosity of the water. (c) The specific mass of the particles suspended in PW was 1.84 g cm -3 , while the diameter of all these particles were lower than 1 mm. (d) The PW head loss for the studied concentrations of the total solids was lower than that for clean water, as decreasing down to 0.4600 dag L -1 and increasing again up to 2.8941 dag L -1 . (e) The empiric models showed better results than the model estimating the friction factor f. The Hazen-Williams’s modified model was the one that better estimating the head loss for any flow rates, total solid concentrations, material types and pipe diameters, therefore being the most recommended. That model on the average underestimates the head loss and generally presents the lowest average errors and standard deviations, so justifying its adjustment in comparison to the other ones. (f) In the practice, the TS (total solid concentration) may be omitted from the equation at the studied TS range, as its effect is considered as a negligible one when the head loss is calculated by the Hazen Williams’s modified model. (g) Since the head loss measured for clean water showed to be higher than 9.7 to 20.8% for the galvanized-iron 130.30 mm pipeline, than 9.7% to 32.0% for the zinc-acid pipeline, than 11.0 to 26.3% for the PVC 79.90 mm pipeline, comparative to those head losses estimated by the Hazen-Williams’s modified model for the poultry raising wastewater, it is recommended the use of equations that would determine the head loss in clean water in dimensioning the hydraulic systems that occasionally transport the poultry wastewater that have the characteristics determined in the current study. / Dissertação importada do Alexandria
20

Filtração de gases: Estudo do fenômeno da limpeza por blocos.

Tieni, Érica Flávia 22 March 2005 (has links)
Made available in DSpace on 2016-06-02T19:56:52Z (GMT). No. of bitstreams: 1 DissEFT.pdf: 2733482 bytes, checksum: 3430708d390441c11e75764bdef622d0 (MD5) Previous issue date: 2005-03-22 / Financiadora de Estudos e Projetos / This work had for purpose to study the phenomenon of patchy cleaning in the operation of the gas filtration, which happens when there is the incomplete regeneration of the filter. A parameter very used to characterize this phenomenon it is the cleaned fraction, which is defined as the ratio between the cleaned areas to the total area of filtration. In order to investigate the patchy cleaning behavior, filtration experiments were accomplished, with the intention to study the action of the cleaning in the fabric of polyester, for different combinations of experimental conditions. To characterize the cleaning for blocks, it has been developed a methodology that includes imagining of the blocks and computer program that analyzes these images of the cake at the end of each cleaning cycle. Using these images it was possible to mark the areas removed with the aim to obtain the size of the removed blocks. The general results showed that: for the maximum pressure drop of 1960 Pa, the fabric presented saturation behavior starting from the second filtration cycle, and for the maximum pressure drop 2939 and 3919 Pa, starting from the fourth filtration cycle. Unlike what was expected, the maximum cleaning velocity was not the one that gives the maximum removal of the cake. The residual pressure drop showed relationship with the distribution of the sizes of the removed blocks. Concerning the quantification of the removed blocks, the removed total area did not present defined behavior with the number of cycles. The largest percentage of the removed blocks presented size between 0,1 e 1 cm2. The area fractions and mass fractions removed presented curves with similar behavior. Besides, the two fractions presented very close values to each other, showing that the technique proposed in this work of quantification of the size of the removed areas presented quite satisfactory results. / Este trabalho teve por objetivo estudar o fenômeno da limpeza por blocos na operação da filtração de gases, que acontece quando há a regeneração incompleta do filtro. Um parâmetro muito utilizado para caracterizar a limpeza por blocos é a fração de limpeza, que pode ser dada tanto como fração de área removida como fração de massa removida. Desta maneira, para investigar esse fenômeno, ensaios de filtração foram realizados, com o intuito de verificar o desempenho da limpeza no tecido de poliéster, para diferentes combinações de condições experimentais. Para caracterizar a limpeza por blocos, desenvolveu-se uma metodologia que consistiu em fotografar a torta ao final de cada limpeza, de modo a obter imagens das tortas parcialmente destacadas. A partir destas imagens, foi possível marcar as áreas removidas em um programa de análise de imagens. Os resultados gerais mostraram que: para a perda de carga máxima de 1960 Pa, o tecido apresentou comportamento de saturação a partir do segundo ciclo de filtração, e para as perdas de carga máxima de 2939 e 3919 Pa, a partir do quarto ciclo de filtração. Ao contrário do que se imaginava, a maior velocidade de limpeza não foi a que apresentou maior eficiência de remoção. A perda de carga residual apresentou íntima relação com a distribuição do tamanho dos pedaços removidos. Com relação ao fenômeno da limpeza por blocos, a área total removida não apresentou comportamento definido com o número de ciclos. Já a maior porcentagem dos pedaços removidos foi relativa aos pedaços com tamanho entre 0,1 e 1 cm2. A comparação entre as frações de massa e de área removida mostrou que o método proposto para quantificar a área removida na operação da filtração apresentou resultados bastante satisfatórios.

Page generated in 0.0765 seconds