• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • 1
  • Tagged with
  • 20
  • 20
  • 10
  • 9
  • 8
  • 6
  • 6
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Tratamento de superfície para dispositivos de implantodontia com antimicrobiano nanoparticulado / Surface treatment for implant devices with nanoparticulate antimicrobial

Nathalia Ferraz Oliscovicz 28 August 2014 (has links)
Os altos índice de sucesso dos implantes dentais e sua indicação crescente apresentam como limitação a contaminação bacteriana com a consequente doença peri-implantar. Os métodos de tratamento ainda não se apresentam claros e seguros, portanto, meios de prevenção que impeçam a formação de biofilme e inibam o crescimento bacteriano devem ser desenvolvidos e aplicados para impedir a falha dos implantes. O objetivo deste estudo foi avaliar a efetividade de um novo antimicrobiano nanoparticulado - o vanadato de prata (AgNO3) em diferentes concentrações (2,5%; 5% e 10%), aplicado sob a forma de filme superficial sobre diferentes substratos sugeridos para dispositivos da Implantodontia. Foram selecionados os materiais poliacetal, teflon e resina acrílica e os veículos glaze e esmalte para a aplicação do nanocomposto. Análises das propriedades físicas rugosidade superficial e dureza Rockwell superficial, assim como imagens obtidas por meio da Microscopia Eletrônica de Varredura (MEV), foram utilizadas para avaliar a resistência e alterações estruturais dos grupos e portanto, a viabilidade de aplicação clínica. A análise pelo método microbiológico do halo de inibição mostrou que as bactérias P. aeruginosa, E. coli, S mutans, E. faecalis e S. aureus tiveram inibição de crescimento; enquanto nas bactérias anaeróbias P. gingivalis e P. intermedia e na levedura C. albicans não foi demonstrada a atividade antibacteriana de AgNO3. O tipo de substrato utilizado e de veículo para a aplicação de AgNO3 não influenciaram nos resultados, com exceção do S. aureus que obteve maior diâmetro do halo de inibição quando aplicado com o glaze em comparação ao esmalte (p<0,05). A proporção do nanocomposto mostrou influência nos resultados, sendo que 10% se mostrou a mais eficaz em todas as bactérias, e de modo geral sem diferença estatística com a proporção de 5% (p<0,05). Apesar de proporções menores algumas vezes não mostrarem atividade antimicrobiana, estas provocaram menor alteração nas propriedades físicas dos materiais, sendo a proporção do AgNO3 proporcional ao aumento da rugosidade e dureza superficial. Os substratos e tipo de filme não influenciaram nos resultados da rugosidade superficial após a aplicação do tratamento superficial (p>0,05), entretanto a aplicação de 10% do nanocomposto causou a alteração superficial mais significativa (7,02 ± 2,99 Ra) (p<0,05). Na dureza superficial não foi encontrada alteração significativa com o aumento da concentração do AgNO3 no poliacetal e na resina acrílica (p>0,05), no entanto no teflon, 10% de AgNO3 não alterou significativamente os valores de resistência. Apesar dos filmes não influenciarem nos resultados, o substrato poliacetal demonstrou maior dureza com diferença estatística com os demais substratos (83,0 ±10,2 HR15Yadaptado) (p<0,05). As imagens obtidas no MEV comprovaram mudanças estruturais superficiais com a presença de mais picos e vales, em comparação a superfícies sem o tratamento antimicrobiano. Como conclusão, apesar de 10% ser a concentração do AgNO3 que atingiu um maior número de espécies, essa concentração deve ser ponderada sobre o seu uso, e avaliada em estudos futuros sobre a sua viabilidade de uso clínico em função das alterações nas propriedades físicas. / The high success rate of dental implants and their growing indications show the limitation of bacterial contamination with consequent peri-implant disease. The treatment methods have not yet clear and secure, thus means for preventing the deposition of biofilm and inhibit bacterial growth must be developed and implemented to prevent failure of implants. The aim of this study was to evaluate the effectiveness of a new nanoparticulate antimicrobial - vanadate silver (AgNO3) in different concentrations (2.5%, 5% and 10%), applied as a surface film on different substrates suggested for devices of Implantology. The materials polyacetal teflon and acrylic resin and vehicles enamel / glaze were selected for the application of nanocomposite. Analyzes of the physical properties surperficial roughness and superficial hardness Rockwell, as well as images obtained by scanning electron microscopy (SEM) were used to assess the strength and structural changes of the groups and therefore the feasibility of clinical application. A microbiological method for the analysis of inhibition zone shows growth inhibition on the bacterias P. aeruginosa, E. coli, S. mutans, E. faecalis and S. aureus; while the anaerobic bacteria P. gingivalis and P. intermedia and the yeast C. albicans has not been demonstrated antibacterial activity of AgNO3. The type of substrate used and the vehicle for the application of AgNO3 did not influence the results, with the exception of S. aureus with highest diameter of inhibition zone when applied with glaze compared to enamel (p<0.05). The proportion of the nanocomposite showed influence on the results, 10% proved the most effective in all bacteria, and generally no statistical difference in the proportion of 5% (p<0.05). Although smaller proportions sometimes do not show antimicrobial activity, these caused minor change in the physical properties of materials. The ratio of AgNO3 was proportional to the increase of roughness and hardness. The substrates and film type did not influence the results of the surface roughness after applying the surface treatment (p>0.05), however the application of 10% of the nanocomposite caused surface alteration more significant (7.02 ± 2.99 Ra) (p<0.05). In hardness was not found to significantly change with concentration of AgNO3 in the acrylic resin and the polyacetal (p> 0.05). However in teflon, 10% AgNO3 did not significantly alter the resistance values. Although the films do not influence the results, polyacetal substrate showed higher hardness with statistical difference with the other substrates (83.0 ± 10.2 HR15Yadaptado) (p <0.05). The SEM images proved superficial structural changes with the presence of more peaks and valleys compared to surfaces without antimicrobial treatment. In conclusion, despite 10% being the concentration of AgNO3 that reached the highest number of species, this concentration should be thought on its use, and evaluated in future studies on the feasibility of clinical use in accordance with changes in physical properties.
12

Prevalência das doenças periimplantares mucosite e periimplantite . Análise de fatores de risco locais e sistêmicos. Estudo retrospectivo de 1 a 9 anos

Buttendorf, André Ricardo January 2012 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T23:26:16Z (GMT). No. of bitstreams: 1 313275.pdf: 1688390 bytes, checksum: 01dfa120b2694b6c11f95f2e8f4480b9 (MD5) / Objetivo : Determinar a prevalência de doenças periimplantares; mucosite e periimplantite, nos pacientes do Centro de Estudos de Educação Continuada em Implantodontia da Universidade Federal de Santa Catarina. Além disso, foi estudada a proporção de implantes afetados. Foi avaliada também a associação de fatores de risco, com as doenças periimplantares, como: Idade; Sexo; Tabaco; Tempo de prótese em função; Localização do implante; Quantidade de mucosa ceratinizada periimplantar. Materiais e Métodos: Um estudo transversal foi realizado em 200 pacientes com 760 implantes hexágono externo apresentando próteses com pelo menos 1 ano de tempo de carregamento (intervalo: 1-09 anos). Profundidade de sondagem, presença de sangramento à sondagem e supuração foram os dados clínicos coletados. Radiografias foram obtidas para avaliar o nível da crista óssea ao redor dos implantes. Mucosite foi definida como uma profundidade de sondagem ? 4 mm com sangramento a sondagem, ao redor do implante, com perda óssea < 2mm. A periimplantite foi definida como uma profundidade de sondagem > 4 mm, associado com sangramento e/ou supuração, e perda óssea ? 2mm. Resultados: Cento e trinta e nove (69%) pacientes apresentavam todos os implantes saudáveis, 46 (23%) pacientes apresentaram ao menos 1 implante com mucosite peri-implantar e 15 (8%) apresentaram peri-implantite. Quinhentos e quarenta e sete (72%) implantes saudáveis, 161 (21%) com mucosite priimplantar e 62 (7%) com periimplantite. Fumo e a quantidade de mucosa ceratinizada se mostraram positivos na relação com as doenças periimplantares. Conclusões: De acordo com os resultados, conclui-se que a prevalência da mucosite peri-implantar foi de 23% e de periimplantite foi 8%. Dos fatores associados estudados, somente o fumo e a quantidade de mucosa ceratinizada < 2mm se mostraram positivos na relação com as doenças periimplantares.<br> / Abstract : Aim: Determine the prevalence of peri-implant diseases; mucositis and periodontitis, of patients from the Center of Studies of Continuing Education in Implant Dentistry of the Federal University of Santa Catarina. In addition, the extension (the proportion of affected implants) was studied. Evaluate the relationship between specific factors (age, sex, smoking, time of prosthesis in function, implant location, and quantity of peri-implant keratinized mucosa) and peri-implant diseases. Materials and Methods: A cross-sectional study was carried out in 200 patients with 760 external-hexed cylindrical implants presenting implant supported prosthesis with at least 1 year of loading time (range: 1-09 years) were included. The probing depth, the presence of bleeding on probing and suppuration were collected. Radiographs are required to evaluate supporting bone levels around implants. Peri-implant mucositis was considered when the probing depth was of ? 4mm with presence of BOP around an implant presenting < 2 mm of bone loss. Peri-implantitis was defined when showing PD of ?4mm, associated with BOP and/or suppuration, and bone loss ? 2mm. Results: One hundred thirty-nine (69%) patients presenting all implants healthy, 46 (23%) patients presented peri-implant mucositis and 15 (8%) presented peri-implantitis. Five hundred and forty-seven (72%) healthy implants, 161(21%) with peri-implant mucostitis and 62 (7%) with peri-implantitis. Conclusions: According to the results, it is concluded that the prevalence of mucositis peri-implant was 23% and peri-implantitis to 8%. Only smoking and quantity of peri-implant KM < 2mm showed positive association with peri-implant diseases.
13

Perda ?ssea peri-implantar de implantes hex?gono externo e cone morse em usu?rios de sobredentaduras mandibulares com carga imediata

Melo, La?rcio Almeida de 04 December 2015 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-04-24T16:37:44Z No. of bitstreams: 1 LaercioAlmeidaDeMelo_DISSERT.pdf: 8251127 bytes, checksum: e4082cba3453aea61dc888d2650b30ca (MD5) / Approved for entry into archive by Monica Paiva (monicalpaiva@hotmail.com) on 2017-04-24T16:56:08Z (GMT) No. of bitstreams: 1 LaercioAlmeidaDeMelo_DISSERT.pdf: 8251127 bytes, checksum: e4082cba3453aea61dc888d2650b30ca (MD5) / Made available in DSpace on 2017-04-24T16:56:08Z (GMT). No. of bitstreams: 1 LaercioAlmeidaDeMelo_DISSERT.pdf: 8251127 bytes, checksum: e4082cba3453aea61dc888d2650b30ca (MD5) Previous issue date: 2015-12-04 / Objetivou-se avaliar a perda ?ssea peri-implantar de implantes Hex?gono Externo (HE) e Cone Morse (CM) em usu?rios de sobredentaduras mandibulares com carga imediata por um per?odo de acompanhamento de 1 ano. O presente estudo trata-se de um ensaio cl?nico controlado e n?o randomizado, no qual foram analisados 18 implantes CM e 22 HE. Radiografias periapicais foram obtidas na instala??o das sobredentaduras e 1 ano ap?s. A perda ?ssea peri-implantar foi analisada a partir da digitaliza??o e an?lise dessas radiografias no programa CorelDRAW X7. Para tal, a medi??o foi feita da plataforma dos implantes at? a crista ?ssea nas faces mesiais e distais de cada implante. Como resultado, verificou-se uma taxa de sucesso elevada nos grupos HE e CM, com taxas de 100% e 94,4% respectivamente. Ao analisar os n?veis ?sseos peri-implantares, observou-se uma diferen?a significantiva entre os grupos (p=0,032), com maiores perdas ?sseas no grupo HE. Em m?dia, a perda ?ssea no grupo HE foi de 0,85mm (?0,82), enquanto no grupo CM foi de 0,10mm (?1,0). Conclui-se, que por um per?odo de 1 ano, maiores perdas ?sseas est?o relacionadas ao grupo HE em compara??o com o grupo CM. / Objetivou-se avaliar a perda ?ssea peri-implantar de implantes Hex?gono Externo (HE) e Cone Morse (CM) em usu?rios de sobredentaduras mandibulares com carga imediata por um per?odo de acompanhamento de 1 ano. O presente estudo trata-se de um ensaio cl?nico controlado e n?o randomizado, no qual foram analisados 18 implantes CM e 22 HE. Radiografias periapicais foram obtidas na instala??o das sobredentaduras e 1 ano ap?s. A perda ?ssea peri-implantar foi analisada a partir da digitaliza??o e an?lise dessas radiografias no programa CorelDRAW X7. Para tal, a medi??o foi feita da plataforma dos implantes at? a crista ?ssea nas faces mesiais e distais de cada implante. Como resultado, verificou-se uma taxa de sucesso elevada nos grupos HE e CM, com taxas de 100% e 94,4% respectivamente. Ao analisar os n?veis ?sseos peri-implantares, observou-se uma diferen?a significantiva entre os grupos (p=0,032), com maiores perdas ?sseas no grupo HE. Em m?dia, a perda ?ssea no grupo HE foi de 0,85mm (?0,82), enquanto no grupo CM foi de 0,10mm (?1,0). Conclui-se, que por um per?odo de 1 ano, maiores perdas ?sseas est?o relacionadas ao grupo HE em compara??o com o grupo CM.
14

Análise microbiológica comparativa da ação de diferentes agentes descontaminantes sobre superfícies de titânio / Microbiological comparison of different decontaminant agents on rough and smooth titanium surfaces: microbiological analysis

Renata Rodrigues de Freitas Blagitz 26 September 2011 (has links)
Os implantes de titânio estabeleceram-se, ao longo do tempo, como uma opção de tratamento com grande índice de sucesso. Entretanto, falhas são passíveis de ocorrer, devido à exposição de suas superfícies ao meio bucal, imediatamente ou até muito tempo passado de sua implantação. Estas superfícies de titânio podem se infectar por bactérias e seus produtos, de forma semelhante à que ocorre na superfície de raízes dentais. Tais contaminantes intensificam a resposta inflamatória, além de alterar a estrutura superficial do implante podendo dar origem às doenças peri-implantares, como a mucosite peri-implantar e a peri-implantite. Para o tratamento destas doenças, diversos métodos de descontaminação de superfícies de implantes têm sido propostos, incluindo o uso substâncias anti-sépticas, jatos abrasivos, ácidos, antibióticos e lasers. O objetivo foi avaliar comparativamente a capacidade de descontaminação do peróxido de hidrogênio a 1,5 % (H2O2), do gluconato de clorexidina a 0,12% (CLX) e do soro fisiológico (SF) já que, até o momento, nenhuma metodologia está estabelecida como padrão ouro para a limpeza superficial. Placa bacteriana foi colhida de sítios de doença periodontal crônica para contaminação de discos de titânio de superfícies lisas e rugosas. Posteriormente, os discos foram submersos em 10 mL das substâncias estudadas por 1 minuto, friccionados com swab e enxaguados em solução fisiológica. Discos controle (C) foram somente enxaguados em soro fisiológico. Desta forma resultaram os seguintes grupos de estudo, constituídos de 5 discos de cada tipo de superfície lisa (L) e rugosa (R): H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL e CL. A avaliação do potencial descontaminante das substâncias foi realizada através da quantificação do crescimento bacteriano pela contagem das unidades formadoras de colônia (UFCs) após semeadura em Agar-brucella e incubação em jarra de CO2 a 37oC por 24 horas. Os resultados após descontaminação foram comparados através da análise de variância a dois critérios (ANOVA) e o nível de significância adotado para todos os testes foi de 5%. Os resultados obtidos permitiram concluir que: as bactérias da periodontite crônica têm capacidade de contaminar e aderir aos discos de titânio nos dois tipos de superfícies estudados; as superfícies lisas e rugosas não diferem entre si quanto aos procedimentos de contaminação e de descontaminação propostos; a clorexidina, o peróxido de hidrogênio e o soro fisiológico apresentaram-se eficientes na descontaminação das superfícies de titânio contaminadas in vitro; houve ligeira superioridade na descontaminação pelo tratamento com a clorexidina de ambas as superfícies de titânio avaliadas. / Actually, the titanium implants are a successful option of treatment in Dentistry. However, failures are possible to occur due to surface exposition to oral environment immediately or lately after its implantation. The titanium implants surfaces can be infected by bacteria and its products similarly to dental roots surfaces. The contaminants turn the inflammatory response tissues more intensive and them alter the surface structure of the implant and cause periimplant diseases like mucositis and peri-implantitis. Several methods of treatment for those diseases have been proposed in the literature, including antiseptics rinses, abrasives air powder, acids, antibiotics and lasers. The aim of this work was to comparatively evaluate the potential for decontamination of the hydrogen peroxide at 1,5% (H2O2), the 0,12% chlorhexidine gluconate (CLX) and the saline solution (SF) as cleaning methods, once until this moment there is not a gold standard method established for this purpose. Bacterial plaque harvested from sites of chronic periodontal disease was used to contaminate smooth and rough surfaces of titanium. Subsequently, decontamination procedures were realized by submerging the discs in 10 ml of the studied substances for 1 minute, cleaned by rubbing with swab and washed on saline solution. Control discs (C) were only washed in saline solution. The following test groups composed by 5 discs of each surface, smooth (L) and rough (R):, were then originated: H2O2 R , CLXR, SFR, CR, H2O2L, CLXL , SFL and CL. The decontaminant potential of studied substances was realized by counting the colony forming units after seeding in Agar-brucella, under anaerobiosis condition for 24 hours under 37oC. The data analysis was made by Variance Analysis (ANOVA) at 5% of significance level. The results lead to the following conclusions: the chronic periodontal biofilm adhesion was possible on smooth and rough titanium surfaces; the surface characteristic had no significant influence on contamination and decontamination method, independently of the substance used; clorhexidine, hydrogen peroxide and saline solution were efficient on decontaminating both types of titanium surfaces in vitro with slightly superiority to clorhexidine.
15

Estudo in vivo e in vitro da corrosão de ligas de Co-Cr e de Ni-Cr utilizadas em estruturas protéticas de implantes orais / In vitro and in vivo studies of corrosion of Co-Cr and Ni-Cr alloys used in oral implant prosthetic superstructures

Inada, Eduardo 13 August 2013 (has links)
Este trabalho avaliou o comportamento eletroquímico de três ligas de níquel-cromo e duas de cobalto-cromo in vitro e in vivo. Nos estudos in vitro foram fabricados eletrodos de trabalho a partir destas ligas. Estes eletrodos ficaram imersos em meio de NaCl 0,15 mol.L-1 a 36,5°C e foram submetidos às técnicas do potencial de circuito aberto, polarização potenciostática anódica e cronoamperometria. Para os estudos in vivo foram selecionados quinze pacientes com implantes já osseointegrados e aguardando a instalação das próteses. Esses pacientes foram distribuídos aleatoriamente em cinco grupos, correspondentes às cinco ligas diferentes. Deste modo, as estruturas protéticas dos implantes foram fundidas utilizando as cinco ligas. Foi utilizada a microscopia eletrônica de varredura (MEV) e a espectroscopia por dispersão de energia (EDS) como métodos de análise das superfícies linguais metálicas das próteses, antes da instalação em ambiente oral e após seis meses de permanência. Vistas por MEV, as ligas duas de cobalto-cromo Starloy C e Remanium 2001 e duas de níquel-cromo Wiron 99 e Remanium CSe apresentaram superfícies heterogêneas caracterizadas por uma fase semelhante à matriz da liga e a outra fase, composta por elementos de maior densidade atômica, correspondente à fase interdendrítica. Após seis meses, não houve sinais de corrosão e alterações significativas na composição destas ligas. As ligas de Co-Cr avaliadas, sob o ponto de vista eletroquímico, indicam comportamento catódico quando unidas ao implante sendo um fator indicativo de proteção à corrosão. Dentro dos limites dos estudos in vitro, as ligas de Ni-Cr apresentaram um filme passivo com ampla faixa de potencial em que se mantêm passiva e ausência de corrosão localizada. A liga de níquel-cromo Dan Ceramalloy apresentou a superfície heterogênea com quatro áreas distintas (área 1 rica em titânio; área 2 rica em níquel; área 3 correspondente à matriz; área 4 rica em molibdênio). Após seis meses, as três próteses metalo-cerâmicas apresentaram as regiões correspondentes à fase 2, rica em níquel, com depressões em baixo relevo, sugerindo a oxidação com a liberação de íons níquel. Nos estudos in vitro a liga Dan Ceramalloy apresenta potencial de corrosão mais negativo, uma faixa passiva de potencial mais estreita e um filme menos protetor, quando comparada com as demais ligas estudadas. Apesar de não ter sido observado clinicamente o processo de corrosão das ligas, os estudos in vitro e in vivo deste material, permitiram verificar o seu comportamento eletroquímico e sugerir a descontinuidade do seu emprego em estruturas protéticas de implantes orais. Os estudos in vitro e in vivo apresentaram concordância para todos os materiais estudados. / In this study, the electro-chemical behavior of three nickel-chrome and two cobalt chrome alloys was studied in vitro and in vivo. In the in vitro studies, working electrodes made of these alloys were fabricated. These electrodes were immersed in a medium of NaCl 0.15 mol.L-1 at 36.5°C and were submitted to the open circuit potential, anodic potentiostatic polarization and chronoamperometry techniques. For the in vivo studies, 15 patients whose implants had osseointegrated, and who were waiting for dental implant placement, were selected. These patients were randomly distributed into five groups, corresponding to the five different alloys. Thus the prosthetic implant superstructures were cast, using the five alloys. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used as methods to analyze the metal lingual surfaces of the prostheses, before they were placed in the oral environment, and after six months in place. Visualized by SEM, the two cobalt-chrome alloys Starloy C and Remanium 2001, and two types of nickel-chrome - Wiron 99 and Remanium Cse - presented heterogeneous surfaces characterized by a phase similar to that of the alloy matrix, and the other phase composed of elements of greater atomic density, corresponding to the interdendritic phase. After six months, there were no signs of corrosion and significant alterations in the composition of these alloys. The Co-Cr alloys evaluated, from an electrochemical point of view, indicated a cathodic behavior when united to the implant, this being a factor indicative of protection against corrosion. Within the limits of the in vitro studies, the Ni-Cr alloys presented a passive film with an ample range of potential in which they remained passive, with absence of corrosion due to pitting. The nickel-chrome alloy Dan Ceramalloy presented a heterogeneous surface with four distinct areas (Area 1 rich in titanium; Area 2 rich in nickel; Area 3 corresponding to the matrix; Area 4 rich in molybdenum). After six months, the three metal-ceramic dental prostheses presented the regions corresponding to Phase 2, rich in nickel, with depressions in low relief, suggesting oxidation with nickel ion release. In the in vitro studies, the alloy Dan Ceramalloy presented a more negative corrosion potential, a narrower range of passive potential and a less protective film, when compared with the other alloys studied. In despite of the process of corrosion of the alloys not having been clinically observed, the in vitro and in vivo studies of this material allowed verification of its electrochemical behavior, and suggest that its use in prosthetic superstructures for oral implants should be discontinued. The in vitro and in vivo studies were shown to be in agreement for all the materials studied.
16

Análise in vitro da ação antibacteriana de filme nanoestruturado contendo partículas de prata aplicado em superfície de titânio / Analysis in vitro of antibacterial effect of nanostructured film with silver particles applied to titanium surface

Lanfredi, Camila Bernardeli 07 December 2012 (has links)
Apesar do alto e significativo índice de sucesso dos implantes osseointegráveis, fracassos podem ser acarretados por diversos fatores, tais como falhas cirúrgicas, protéticas, trauma oclusal e por infecções nos tecidos ao redor do implante. As lesões inflamatórias desenvolvidas ao redor de implantes são conhecidas coletivamente como doença peri-implantar, que possui um papel muito importante na falência de implantes, sendo considerada uma das principais causas. O objetivo deste trabalho foi analisar a ação antibacteriana de filme nanoestruturado com partículas de prata aplicado em superfície de titânio de componentes protéticos conectados a implantes, em relação às bactérias predominantes na infecção peri-implantar. Para avaliar a ação antibacteriana do filme nanoestruturado com partículas de prata foi realizado teste microbiológico com cepas de Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) e Porphyromonas gingivalis (ATCC 33277). Discos de titânio sem tratamento formaram o grupo controle (Ti) e discos com filme nanoestruturado com partículas de prata, o grupo teste (NT-Ag). Cada teste foi realizado em triplicata e repetido por três ocasiões separadas. Após 48 horas de incubação dos discos em caldo de infusão de cérebro e coração (BHI), previamente inoculado com as cepas, a 37 °C, em anaerobiose, os discos foram então retirados e colocados em um tubo contendo solução tampão fosfato-salina (PBS) e centrifugados por 1 minuto em aparelho tipo vortex. O PBS foi diluído em série até 1:100.000, distribuído em placas de ágar sangue e essas foram incubadas por 48 horas, a 37ºC, em anaerobiose e então foi feita a contagem de colônias sobre as placas para posterior calculo das unidades formadoras de colônia (UFC). A análise da adesão bacteriana foi realizada com cepas de Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) e Porphyromonas gingivalis (ATCC 33277), através da leitura dos discos em microscópio eletrônico de varredura Leo 43, após imersão dos discos em BHI inoculado. O teste antibacteriano, realizado com Aggregatibacter actinomycetemcomitans, apresentou valor médio de UFC/mL do grupo teste (NT-Ag) semelhante ao obtido do grupo controle (Ti), não havendo diferença estatística (p<0,01) entre eles. Os testes realizados com Fusobacterium nucleatum e Porphyromonas gingivalis não apresentaram crescimento bacteriano, na etapa de leitura das placas, para os dois grupos, controle (Ti) e teste (NT-Ag). As imagens obtidas, através do microscópio eletrônico de varredura (MEV), demonstraram uma notável redução da adesão bacteriana, nos discos com filme nanoestruturado com partículas de prata (NT-Ag), em comparação com as imagens do grupo controle (Ti), para todas as cepas, porém não são conclusivas. O filme nanoestruturado com partículas de prata não foi efetivo na redução da adesão de A. actinomycetemcomitans. / Despite the high and significant success rate of dental implants, failures can be posed by various factors such as surgical and prosthetic failures, oclusal trauma and infections in the tissues around the implant. The inflammatory lesions developed around implants are collectively known as peri-implant disease, which has a very important role in implant failure and is considered one of the main causes. The aim of this study was to evaluate the antibacterial activity of nanostructured film with silver particles, applied on abutments connected to implants, in relation to the predominant bacteria in peri-implant infection. To evaluate the antibacterial activity of the nanostructured film, microbiological tests were performed with strains of Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) and Porphyromonas gingivalis (ATCC 33277). Untreated titanium discs were the control group (Ti) and discs with the nanostructured film with silver particles formed the test group (NT-Ag). Each test was run in triplicate and repeated on three separate occasions. After 48 hours of discs incubation in brain heart infusion broth (BHI), previously inoculated with the strains, at 37 °C, under anaerobic conditions, the discs were then removed and placed in a tube containing phosphate buffered saline solution (PBS) and vortexed for 1 minute. The PBS was serially diluted up to 1:100,000, distributed in blood agar plates and incubated for 48 hours, at 37 ° C in anaerobiosis and then colonies were counted for subsequent calculation of colony forming units (CFU). The analysis of bacterial adhesion was performed with strains of Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) and Porphyromonas gingivalis (ATCC 33277) by reading the discs surface in a scanning electron microscope Leo 43, after immersion of the discs on inoculated BHI. The antibacterial test, performed with Aggregatibacter actinomycetemcomitans, obtained CFU/mL medium value from the test group (NT-Ag) similar to the obtained in the control group (Ti), showing no statistical difference (p <0.01) between them. The tests performed with Fusobacterium nucleatum and Porphyromonas gingivalis showed no bacterial growth, in plates reading step, for both groups, control (Ti) and test (NT-Ag). The images obtained by scanning electron microscopy showed a remarkable reduction of bacterial adhesion, on discs with nanostructured film with silver particles (NT-Ag), when compared to the images of the control group (Ti), for all strains, but they were not conclusive. The nanostructured film with silver particles was not effective in reducing bacterial adhesion of A. actinomycetemcomitans.
17

Análise in vitro da ação antibacteriana de filme nanoestruturado contendo partículas de prata aplicado em superfície de titânio / Analysis in vitro of antibacterial effect of nanostructured film with silver particles applied to titanium surface

Camila Bernardeli Lanfredi 07 December 2012 (has links)
Apesar do alto e significativo índice de sucesso dos implantes osseointegráveis, fracassos podem ser acarretados por diversos fatores, tais como falhas cirúrgicas, protéticas, trauma oclusal e por infecções nos tecidos ao redor do implante. As lesões inflamatórias desenvolvidas ao redor de implantes são conhecidas coletivamente como doença peri-implantar, que possui um papel muito importante na falência de implantes, sendo considerada uma das principais causas. O objetivo deste trabalho foi analisar a ação antibacteriana de filme nanoestruturado com partículas de prata aplicado em superfície de titânio de componentes protéticos conectados a implantes, em relação às bactérias predominantes na infecção peri-implantar. Para avaliar a ação antibacteriana do filme nanoestruturado com partículas de prata foi realizado teste microbiológico com cepas de Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) e Porphyromonas gingivalis (ATCC 33277). Discos de titânio sem tratamento formaram o grupo controle (Ti) e discos com filme nanoestruturado com partículas de prata, o grupo teste (NT-Ag). Cada teste foi realizado em triplicata e repetido por três ocasiões separadas. Após 48 horas de incubação dos discos em caldo de infusão de cérebro e coração (BHI), previamente inoculado com as cepas, a 37 °C, em anaerobiose, os discos foram então retirados e colocados em um tubo contendo solução tampão fosfato-salina (PBS) e centrifugados por 1 minuto em aparelho tipo vortex. O PBS foi diluído em série até 1:100.000, distribuído em placas de ágar sangue e essas foram incubadas por 48 horas, a 37ºC, em anaerobiose e então foi feita a contagem de colônias sobre as placas para posterior calculo das unidades formadoras de colônia (UFC). A análise da adesão bacteriana foi realizada com cepas de Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) e Porphyromonas gingivalis (ATCC 33277), através da leitura dos discos em microscópio eletrônico de varredura Leo 43, após imersão dos discos em BHI inoculado. O teste antibacteriano, realizado com Aggregatibacter actinomycetemcomitans, apresentou valor médio de UFC/mL do grupo teste (NT-Ag) semelhante ao obtido do grupo controle (Ti), não havendo diferença estatística (p<0,01) entre eles. Os testes realizados com Fusobacterium nucleatum e Porphyromonas gingivalis não apresentaram crescimento bacteriano, na etapa de leitura das placas, para os dois grupos, controle (Ti) e teste (NT-Ag). As imagens obtidas, através do microscópio eletrônico de varredura (MEV), demonstraram uma notável redução da adesão bacteriana, nos discos com filme nanoestruturado com partículas de prata (NT-Ag), em comparação com as imagens do grupo controle (Ti), para todas as cepas, porém não são conclusivas. O filme nanoestruturado com partículas de prata não foi efetivo na redução da adesão de A. actinomycetemcomitans. / Despite the high and significant success rate of dental implants, failures can be posed by various factors such as surgical and prosthetic failures, oclusal trauma and infections in the tissues around the implant. The inflammatory lesions developed around implants are collectively known as peri-implant disease, which has a very important role in implant failure and is considered one of the main causes. The aim of this study was to evaluate the antibacterial activity of nanostructured film with silver particles, applied on abutments connected to implants, in relation to the predominant bacteria in peri-implant infection. To evaluate the antibacterial activity of the nanostructured film, microbiological tests were performed with strains of Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) and Porphyromonas gingivalis (ATCC 33277). Untreated titanium discs were the control group (Ti) and discs with the nanostructured film with silver particles formed the test group (NT-Ag). Each test was run in triplicate and repeated on three separate occasions. After 48 hours of discs incubation in brain heart infusion broth (BHI), previously inoculated with the strains, at 37 °C, under anaerobic conditions, the discs were then removed and placed in a tube containing phosphate buffered saline solution (PBS) and vortexed for 1 minute. The PBS was serially diluted up to 1:100,000, distributed in blood agar plates and incubated for 48 hours, at 37 ° C in anaerobiosis and then colonies were counted for subsequent calculation of colony forming units (CFU). The analysis of bacterial adhesion was performed with strains of Aggregatibacter actinomycetemcomitans (ATCC 43719), Fusobacterium nucleatum (ATCC 25586) and Porphyromonas gingivalis (ATCC 33277) by reading the discs surface in a scanning electron microscope Leo 43, after immersion of the discs on inoculated BHI. The antibacterial test, performed with Aggregatibacter actinomycetemcomitans, obtained CFU/mL medium value from the test group (NT-Ag) similar to the obtained in the control group (Ti), showing no statistical difference (p <0.01) between them. The tests performed with Fusobacterium nucleatum and Porphyromonas gingivalis showed no bacterial growth, in plates reading step, for both groups, control (Ti) and test (NT-Ag). The images obtained by scanning electron microscopy showed a remarkable reduction of bacterial adhesion, on discs with nanostructured film with silver particles (NT-Ag), when compared to the images of the control group (Ti), for all strains, but they were not conclusive. The nanostructured film with silver particles was not effective in reducing bacterial adhesion of A. actinomycetemcomitans.
18

Influência de fatores alimentares no nível sérico de vitamina D e o efeito da hipovitaminose D sobre condições clínica e radiográfica de pacientes com próteses sobre implantes / Influence of food factors in the serum level of vitamin d and the effect of hypovitaminose d on clinical and radiographic conditions of patients with implant prostheses

Verde, Luis Henrique Cerqueira Vila 03 March 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T15:05:21Z No. of bitstreams: 2 Luís Henrique Cerqueira Vila Verde.pdf: 1205701 bytes, checksum: 917c89ccf0c450e4e8d17634346f026b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T15:05:21Z (GMT). No. of bitstreams: 2 Luís Henrique Cerqueira Vila Verde.pdf: 1205701 bytes, checksum: 917c89ccf0c450e4e8d17634346f026b (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Vitamin D (VD) plays an important role in the development and maintenance of bone tissue. At normal levels, it has positive effect on volume, bone quality as well as its density. Considering the large number of people who present serum changes of the same, this research aims to observe the rate of hypovitaminosis D (hD) in the study population and the factors that may influence the incidence of hD, and to evaluate the influence of hD on peri-implant clinical and radiographic conditions. All the participants of the groups were submitted to a Semi-quantitative Food Frequency Questionnaire on the intake of dietary calcium (QFASQ), in order to evaluate the risk factors. Patients were submitted to laboratory tests of 25-hydroxyvitamin D dosing, those with a serum LDL level of less than 30ng / mL were allocated to the abnormal (insufficient or defficient) group and the participants with dosages equal to or greater than 30ng/mL were allocated to the normal (sufficient) group. Participants received the following evaluations: peri-implant clinical analysis (depth of probing, keratinized mucosa width, modified groove bleed index, modified plaque index), radiographic analysis (distance between the implant cervical and the mesial and distal). Patients who were allocated to the abnormal group were submitted to VD replacement, and a new clinical and radiographic analysis was performed. It was found that in the initial study population about 36% of individuals had hD. As for the food questionnaire, lower intake of milk products, such as yogurt and lower frequency of physical activities, showed a higher risk for one hD. Clinical analysis showed that VD was statistically non-statistically significant for probing depth, keratinized mucosal width, modified plaque index, and for modified bleeding index between the 2 periods, in relation to peri-implant parameters. It was concluded that less than half of the sample had hD and calcium-rich foods may contribute to normal serum levels of VD. VD did not influence the peri-implant clinical parameters studied. / A vitamina D (VD) tem um papel importante no desenvolvimento e na manutenção do tecido ósseo. Em níveis normais, ela tem efeito positivo sobre volume, qualidade óssea, bem como sua densidade. Considerando o grande número de pessoas que apresentam alterações séricas da mesma, esta pesquisa visa observar a taxa de hipovitaminose D (hD) na população estudada e os fatores que podem influenciar na incidência de hD, e avaliar a influência da hD nas condições clínica e radiográfica peri-implantar. Todos os participantes dos grupos foram submetidos a um Questionário de Frequência Alimentar Semi-quantitativo sobre a ingestão de cálcio alimentar (QFASQ), visando avaliar os fatores de risco. Os pacientes foram submetidos a exames laboratoriais de dosagem de 25- hidroxivitamina D, aqueles que apresentaram uma dosagem sérica de VD inferior a 30ng/mL foram alocados no grupo anormal (insuficiente ou deficiente) e os participantes com dosagem igual ou acima de 30ng/mL foram alocados ao grupo normal (suficiente). Os participantes receberam as seguintes avaliações: análise clínica peri-implantar (profundidade de sondagem, largura da mucosa queratinizada, índice de sangramento do sulco modificado, índice de placa modificado), análise radiográfica (distância entre a cervical do implante e as cristas ósseas mesial e distal). Os pacientes que foram alocados no grupo anormal foram submetidos à reposição da VD, e após a reposição, uma nova analise clinica e radiográfica foi realizada. Constatou-se que na população inicial do estudo cerca 36% dos indivíduos tinham hD. Quanto ao questionário alimentar, menor quantidade de ingestão de derivados do leite, como o iogurte e a menor frequência de atividades físicas mostraram maior risco para uma hD. A análise clinica demonstrou que VD se comportou, em relação aos parâmetros peri-implantares, de forma não significativa, estatisticamente, para profundidade de sondagem, largura de mucosa queratinizada, índice de placa modificado e para índice de sangramento modificado entre os 2 períodos. Concluiu-se que menos da metade da amostra apresentou hD e os alimentos ricos em cálcio podem contribuir para níveis séricos de VD normais. A VD não influenciou nos parâmetros clínicos peri-implantares estudados.
19

Estudo in vivo e in vitro da corrosão de ligas de Co-Cr e de Ni-Cr utilizadas em estruturas protéticas de implantes orais / In vitro and in vivo studies of corrosion of Co-Cr and Ni-Cr alloys used in oral implant prosthetic superstructures

Eduardo Inada 13 August 2013 (has links)
Este trabalho avaliou o comportamento eletroquímico de três ligas de níquel-cromo e duas de cobalto-cromo in vitro e in vivo. Nos estudos in vitro foram fabricados eletrodos de trabalho a partir destas ligas. Estes eletrodos ficaram imersos em meio de NaCl 0,15 mol.L-1 a 36,5°C e foram submetidos às técnicas do potencial de circuito aberto, polarização potenciostática anódica e cronoamperometria. Para os estudos in vivo foram selecionados quinze pacientes com implantes já osseointegrados e aguardando a instalação das próteses. Esses pacientes foram distribuídos aleatoriamente em cinco grupos, correspondentes às cinco ligas diferentes. Deste modo, as estruturas protéticas dos implantes foram fundidas utilizando as cinco ligas. Foi utilizada a microscopia eletrônica de varredura (MEV) e a espectroscopia por dispersão de energia (EDS) como métodos de análise das superfícies linguais metálicas das próteses, antes da instalação em ambiente oral e após seis meses de permanência. Vistas por MEV, as ligas duas de cobalto-cromo Starloy C e Remanium 2001 e duas de níquel-cromo Wiron 99 e Remanium CSe apresentaram superfícies heterogêneas caracterizadas por uma fase semelhante à matriz da liga e a outra fase, composta por elementos de maior densidade atômica, correspondente à fase interdendrítica. Após seis meses, não houve sinais de corrosão e alterações significativas na composição destas ligas. As ligas de Co-Cr avaliadas, sob o ponto de vista eletroquímico, indicam comportamento catódico quando unidas ao implante sendo um fator indicativo de proteção à corrosão. Dentro dos limites dos estudos in vitro, as ligas de Ni-Cr apresentaram um filme passivo com ampla faixa de potencial em que se mantêm passiva e ausência de corrosão localizada. A liga de níquel-cromo Dan Ceramalloy apresentou a superfície heterogênea com quatro áreas distintas (área 1 rica em titânio; área 2 rica em níquel; área 3 correspondente à matriz; área 4 rica em molibdênio). Após seis meses, as três próteses metalo-cerâmicas apresentaram as regiões correspondentes à fase 2, rica em níquel, com depressões em baixo relevo, sugerindo a oxidação com a liberação de íons níquel. Nos estudos in vitro a liga Dan Ceramalloy apresenta potencial de corrosão mais negativo, uma faixa passiva de potencial mais estreita e um filme menos protetor, quando comparada com as demais ligas estudadas. Apesar de não ter sido observado clinicamente o processo de corrosão das ligas, os estudos in vitro e in vivo deste material, permitiram verificar o seu comportamento eletroquímico e sugerir a descontinuidade do seu emprego em estruturas protéticas de implantes orais. Os estudos in vitro e in vivo apresentaram concordância para todos os materiais estudados. / In this study, the electro-chemical behavior of three nickel-chrome and two cobalt chrome alloys was studied in vitro and in vivo. In the in vitro studies, working electrodes made of these alloys were fabricated. These electrodes were immersed in a medium of NaCl 0.15 mol.L-1 at 36.5°C and were submitted to the open circuit potential, anodic potentiostatic polarization and chronoamperometry techniques. For the in vivo studies, 15 patients whose implants had osseointegrated, and who were waiting for dental implant placement, were selected. These patients were randomly distributed into five groups, corresponding to the five different alloys. Thus the prosthetic implant superstructures were cast, using the five alloys. Scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used as methods to analyze the metal lingual surfaces of the prostheses, before they were placed in the oral environment, and after six months in place. Visualized by SEM, the two cobalt-chrome alloys Starloy C and Remanium 2001, and two types of nickel-chrome - Wiron 99 and Remanium Cse - presented heterogeneous surfaces characterized by a phase similar to that of the alloy matrix, and the other phase composed of elements of greater atomic density, corresponding to the interdendritic phase. After six months, there were no signs of corrosion and significant alterations in the composition of these alloys. The Co-Cr alloys evaluated, from an electrochemical point of view, indicated a cathodic behavior when united to the implant, this being a factor indicative of protection against corrosion. Within the limits of the in vitro studies, the Ni-Cr alloys presented a passive film with an ample range of potential in which they remained passive, with absence of corrosion due to pitting. The nickel-chrome alloy Dan Ceramalloy presented a heterogeneous surface with four distinct areas (Area 1 rich in titanium; Area 2 rich in nickel; Area 3 corresponding to the matrix; Area 4 rich in molybdenum). After six months, the three metal-ceramic dental prostheses presented the regions corresponding to Phase 2, rich in nickel, with depressions in low relief, suggesting oxidation with nickel ion release. In the in vitro studies, the alloy Dan Ceramalloy presented a more negative corrosion potential, a narrower range of passive potential and a less protective film, when compared with the other alloys studied. In despite of the process of corrosion of the alloys not having been clinically observed, the in vitro and in vivo studies of this material allowed verification of its electrochemical behavior, and suggest that its use in prosthetic superstructures for oral implants should be discontinued. The in vitro and in vivo studies were shown to be in agreement for all the materials studied.
20

Development of nanostructured and bioactive surfaces onto ceramic substrates

Carvalho, Ângela Marisa Pereira January 2011 (has links)
Tese de mestrado. Engenharia Biomédica. Faculdade de Engenharia. Universidade do Porto. 2011

Page generated in 0.0744 seconds