• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 61
  • 23
  • 5
  • 1
  • Tagged with
  • 89
  • 89
  • 43
  • 43
  • 25
  • 20
  • 17
  • 17
  • 14
  • 13
  • 13
  • 13
  • 13
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Application of sputtering to micro gas chromatography : a novel collective stationary phase disposition technique for micro gas chromatography columns fabrication : feasibility, evaluations and oilfield applications. / Application de la pulvérisation cathodique à la chromatographie en phase gazeuse miniature : une nouvelle technique de dépôt collectif de la phase stationnaire pour la fabrication de micro colonnes sur puce : faisabilité, caractérisations, et applications pétrolières.

Haudebourg, Raphael 05 February 2014 (has links)
Une nouvelle technique de dépôt de phases stationnaires solides pour la fabrication de micro colonnes de chromatographie en phase gazeuse a été proposée : pour dépasser les limites des phases stationnaires liquides conventionnelles (ou occasionnellement solides) en termes de rétention des composés très volatiles et/ou de fabrication par lots en salle blanche, une approche consistant en le dépôt direct de l'adsorbant sur le substrat par pulvérisation cathodique a été mise en œuvre. La méthode est par nature compatible avec le procédé de fabrication en salle blanche et industrialisable, et a montré de bons résultats en termes de précision. La séparation d'hydrocarbures volatiles a été rendue possible sur silice, alumine, graphite et magnésie. Différents types de colonnes (structure, phase stationnaire) ont été fabriquées sous la forme de puces en silicium de 2x2 cm², et leurs caractérisations thermodynamique et cinétique ont été réalisées. Des efficacités très satisfaisantes ont été obtenues (plus de 5700 plateaux, des hauteurs de plateau de 250 µm). La possibilité d'utiliser des colonnes à phase stationnaire déposée par pulvérisation cathodique pour l'analyse automatisée en temps réel d'hydrocarbures légers sur site pétrolier a été démontrée par l'implémentation d'un système de programmation en température de la puce et divers tests d'adaptabilité (haute température, gaz vecteur, humidité) : une séparation complète des alcanes linéaires C1-C9 en moins de 15 secondes a été obtenue, ainsi que des séparations de mélanges plus complexes (isomères, insaturés). Une application industrielle confidentielle a été brevetée et développée. / A totally new solid stationary phase deposition technique for micro machined gas chromatography (GC) columns fabrication was proposed: to overcome the limitations of conventional liquid (or occasionally solid) stationary phases in terms of very volatile compounds retention and/or clean room batch production, an approach consisting of the collective direct deposition of the adsorbent in micro columns channels by sputtering was performed. The process was fully compatible with clean room fabrication flow and industry-ready, with very good precision results. Silica, alumina, graphite and magnesia were proven able to separate volatile hydrocarbons. Various types of columns (structure, stationary phase) were fabricated in the form of 2x2 cm² silicon-Pyrex chips, and their thermodynamic and kinetic evaluations were reported. Retentions were observed to increase from magnesia to graphite through alumina and silica and with phase ratio decrease, as expected; very satisfying efficiencies were obtained: more than 5700 plates, and 250 µm-high plates. The possibility to use such columns for fast in-situ and autonomous monitoring of light hydrocarbons in oilfield environments was demonstrated by the implementation of a chip temperature-programming system and various versatility tests (high temperatures, carrier gas, humidity): a complete C1-C9 linear alkanes separation was performed in less than 15 seconds, as well as complex mixtures fast separations (isomers, unsaturated), and an industrial confidential application was developed and patented. Therefore, sputter-deposited stationary phase micro columns opened numerous perspectives for the developments of miniaturized GC apparatuses.
22

Astrochimie expérimentale : cinétique des réactions neutre-neutre à basse température et pertinence pour la chimie des atmosphères planétaires et des nuages interstellaires / Experimental astrochemistry : the kinetics of neutral-neutral reactions at low temperature and their relevance to the chemistry of planetary atmospheres and interstellar clouds

Núñez Reyes, Dianailys 19 March 2019 (has links)
Les 50 dernières années ont été caractérisées par le développement rapide de l’astrochimie. Plus de 150 réactions entre espèces neutres ont déjà été étudiées aux basses températures qui sont celles du le milieu interstellaire et des atmosphères planétaires. Néanmoins, les constantes de vitesse, et la nature des produits, restent inconnus pour de nombreuses réactions potentiellement importantes pour caractériser ces milieux. Nous avons effectué des études cinétiques pour des processus réactifs, et non réactifs, entre des atomes dans un état électronique excité [C(1D), O(1D) et N(2D)] et plusieurs molécules stables afin de quantifier leur importance dans la chimie des atmosphères planétaires. Nous avons aussi étudié la réaction entre les atomes de carbone dans leur état électronique fondamental (3P) et l’eau, confirmant l’importance, pour certaines réactions avec barrière, de l’effet tunnel pour la réactivité à basse température. Les constantes de vitesse et les rapports de branchement pour ces processus ont été déterminés dans la gamme de température entre 50 et 296 K en utilisant un appareil CRESU, les atomes étudiés ont été produits par photolyse à l’aide d’un laser pulsé (PLP) et détectés par fluorescence induite dans l’ultraviolet sous vide (VUV LIF). / The last 50 years have been characterized by the fast development of astrochemistry as a science. To date, more than 150 gas-phase neutral-neutral reactions have been investigated at low temperatures relevant to planetary atmospheres and in cold regions of the interstellar medium. However, the rate constants and nature of the products for many potentially important gas-phase processes remain unknown. We performed kinetic studies of reactive and non-reactive removal processes between electronically excited atoms [C(1D), O(1D) and N(2D)] with several molecules in order to quantify their importance in the chemistry of planetary atmospheres. Furthermore, we also investigated the reaction between carbon atoms in their ground electronic state (3P) with water, providing new evidence of a quantum mechanical tunnelling mechanism at low temperatures, which could play an important role in the chemistry of interstellar clouds. Rate constants and branching ratios for these processes were determined over the 50 - 296 K temperature range using a CRESU (Cinétique de Réaction en Ecoulement Supersonique Uniforme) apparatus coupled with pulsed laser photolysis (PLP) and vacuum ultraviolet laser induced fluorescence (VUV LIF).
23

Contribution au profilage des acides organiques urinaires, chez l'enfant / Contribution to profiling urinary organic acids in children

Pérez-Vásquez, Naira 10 April 2015 (has links)
La chromatographie en phase gazeuse couplée à la spectrométrie de masse simple quadripolaire (GC-qMS) est la technique la plus utilisée dans l’exploration des acides organiques urinaires dans le cadre du diagnostic des aciduries organiques (AO). Cependant, après analyse par GC-MS de plus de 1000 échantillons d'urines recueillis auprès d'enfants atteints de troubles neurologiques, moins de 0,5% d'entre eux ont reçu un diagnostic positif. Ceci témoigne de l’urgence de rechercher de nouveaux biomarqueurs dans le domaine des troubles neurologiques associés à des erreurs innées du métabolisme (EIM).L'objectif principal de cette thèse a été de développer une nouvelle méthode d’analyse des échantillons urinaires par chromatographie bidimensionnelle couplée à la spectrométrie de masse (GCxGC-qMS) et d'évaluer son apport dans le profilage métabolique de ces échantillons. Par ailleurs, dans le cadre du diagnostic des AO, dans un objectif de simplification de la procédure de préparation de l’échantillon, nous avons évalué une autre approche d’analyse directe en temps réel couplée à la spectrométrie de masse « DART-MS » des acides organiques urinaires. La première étape de notre travail a été de développer un protocole de préparation de l’échantillon compatible avec une méthode de séparation bidimensionnelle. Puis, grâce à l’étude systématique des différentes conditions de séparation, nous avons développé une méthode par CGxCG-qMS parfaitement adaptée à la séparation des composés extraits.Après validation analytique, la méthode proposée a été ensuite évaluée par le profilage des composés organiques présents dans des échantillons urinaires prélevés chez des volontaires sains. Par rapport aux profils obtenus par une méthode par GC-qMS classique, optimisée, les profils chromatographiques obtenus par la méthode proposée présentent une sensibilité et une résolution nettement plus élevées. Ceci se traduit par la détection en GCxGC-qMS de nombreux composés supplémentaires, jusqu’à 92, selon les échantillons. Parmi les composés supplémentaires détectés et caractérisés, certains sont d’un intérêt diagnostic reconnu.Malgré les difficultés liées à l’étape de préparation de l’échantillon et au traitement des données, l’ensemble des résultats obtenus par la méthode proposée sur de nombreux échantillons urinaires a confirmé les potentialités et la nécessité d’utiliser la chromatographie bidimensionnelle dans le domaine de la découverte de candidats biomarqueurs. Il s’agit maintenant de poursuivre l’identification des composés supplémentaires détectés dans les échantillons urinaires étudiés et d’appliquer la méthode proposée à un plus grand nombre d’échantillons témoins et pathologiques afin d’essayer d’identifier des candidats biomarqueurs.Enfin, les essais préliminaires par la technique DART-MS, effectués dans un laboratoire de la Direction des Applications Militaires (DAM) du CEA, ont été axés sur la détection d’un panel d’acides organiques représentatifs des différentes anomalies rencontrées lors des AO. Malgré les effets de suppression ionique qui restent à éliminer, les résultats obtenus montrent que cette approche mérite d’être approfondie. / Among inherited metabolic diseases, organic acidemia (OA) or organic aciduria is characterized by urinary excretion of abnormal amounts or types of organic acids. OA is mostly associated with genetic conditions resulting in a specific step of amino acid catabolism dysfunction. Such alterations can produce disease states that range from mild to lethal neurological involvement. Gas chromatography coupled to mass spectrometry (GC-MS) remains the most used analytical technique for detecting specific urinary organic metabolites related to OA. However, after analyzing more than 1,000 urine samples collected from children with neurological disorders, by this technique less than 0.5% of them were positive. Thus, the discovery of new biomarker candidates for other metabolic diseases is urgently needed. The main objective of this thesis was to evaluate a new method using two-dimensional gas chromatography coupled to mass spectrometry (GCxGC-MS) for the both qualitative and quantitative metabolic profiling of children’s urine. As compared to GC-MS, GCxGC-MS shows great resolution power and high peak capacity. For this purpose, we first developed a GCxGC-MS method with an appropriate sample preparation protocol for urinary organic acids profiling. Applied to urine samples of healthy children and children with neurological disorders, the proposed method showed high sensitivity and peak capacity thus opening new possibilities for the characterization of new biomarker candidates. For instance, by this technique, we were able to detect in urines samples more than ninety additional compounds, which are not detected by a conventional GC-MS method. However, taken together the obtained results show that while the GCxGC technique has unmatched power to separate compounds in a complex mixture, the sample preparation protocol remains a limiting step for the precise quantification of the detected compounds. On another hand, in order to reduce the sample preparation step, we evaluated the direct analysis in real time (DART) method for the urinary organic acids screening. The obtained results are very promising.
24

Effect of condensable materials during the gas phase polymerization of ethylene on supported catalysts / Effet des matériaux condensables au cours de la polymérisation en phase gazeuse d'éthylène sur des catalyseurs supporté

Nascimento de Andrade, Fabiana 01 February 2019 (has links)
Les réacteurs à lit fluidisé (FBR) constituent la seule technologie viable sur le plan commercial pour la production de polyéthylène en phase gaz, car la polymérisation est hautement exothermique et le FBR est le seul type de réacteur en phase gaz offrant des possibilités suffisantes de transfert de chaleur. La nature hautement exothermique de cette polymérisation pose effectivement de nombreux problèmes pour le fonctionnement en phase gaz et peut limiter la production de certains procédés. Au cours des dernières années, les procédés en lit fluidisé ont été améliorés par de nouvelles technologies. En particulier, l'ajout d'hydrocarbures inertes (généralement liquides) permet d'augmenter la quantité de chaleur évacuée du réacteur. Ces composés augmentent la capacité calorifique de la phase gazeuse et, s’ils sont injectés sous forme liquide, s’évaporent également et absorbent ainsi encore plus efficacement la chaleur du milieu réactionnel. C’est ce qu’on appelle le fonctionnement en mode condensé. On y utilise des composés qui peuvent être liquéfiés dans le condenseur de recyclage et qui sont appelés agents de condensation induits (en anglais : Induced Condensing Agents - ICA). L’utilisation de l’ICA est extrêmement importante d'un point de vue industriel. L’injection d’ICA peut avoir de nombreux effets physiques différents au niveau des particules de polymère en croissance. Par exemple, l’ajout de ces composés peut entraîner des modifications de la solubilité et d’autres propriétés physiques, ce qui peut faciliter le transport de l’éthylène et de l’hydrogène vers les sites actifs des catalyseurs. Il est donc très important que les phénomènes physiques liés à l'équilibre de sorption entre la phase gaz et la phase polymère du ou des monomères et d'autres espèces, ainsi que leur diffusion dans la matrice polymère au niveau des sites actifs, soient pris en compte. En plus d'avoir un effet sur la cinétique, ces phénomènes peuvent également impacter la structure des molécules de polymère et par conséquent changer les caractéristiques du polymère. Identifier le comportement de ces phénomènes dans les conditions de la procédé et les variables de contrôle du rapport hydrogène / éthylène et du rapport comonomère / éthylène avec l'ICA sont les objectifs centraux de cette étude. Une série d’homo- et co-polymérisations d’éthylène en phase gazeuse a été réalisée en utilisant un catalyseur commercial Ziegler-Natta en présence de l’ICA (propane, n pentane et n-hexane). Nous avons étudié l’effet des températures, de la pression partielle de l’ICA, de l'hydrogène et des comonomères sur le comportement de la polymérisation. Il a été constaté que l’ajout de l’ICA augmentait significativement la vitesse de réaction ainsi que les poids moléculaires moyens à une température donnée. De manière inattendue, il a également été observé que l’augmentation de la température du réacteur en présence d’ICA entraînait en réalité une diminution de la vitesse de réaction globale. Ces résultats ont été attribués à l’effet de cosolubilité. Dans les réactions en présence de différentes concentrations en hydrogène, pour un rapport ICA/C2 beaucoup plus grand que le rapport H2/C2, l'effet de l’ICA sur la solubilité de l’éthylène peut compenser la diminution en taille des molécules provoquée par la présence d’hydrogène. L’impact de l’ICA sur les taux de réaction de copolymérisation est plus prononcé aux stades initiaux, perdant de son efficacité en raison de l'effet de comonomère. Enfin, une évaluation de la cinétique de cristallisation dans des conditions isothermes pour des mélanges de différentes concentrations ICA: HDPE a montré que le temps de cristallisation est significativement plus long pour les systèmes riches en ICA que pour les polymères secs / Fluidized bed reactors (FBR) are the only commercially viable technology for the production of polyethylene in the gas phase since the polymerization is highly exothermic and the FBR is the only type of gas phase reactor that offers adequate possibilities of heat transfer. The highly exothermic nature of this polymerization effectively poses many problems for gas phase operation and can limit the production of a certain process. However, in recent years the fluidized bed processes have been improved with new technologies. In particular, the addition of inert (usually liquefied) hydrocarbons allows one to increase the amount of heat removed from the reactor. These compounds increase the heat capacity of the gas phase and, if injected in liquid form, also evaporate and thus absorb even more heat from the reaction medium efficiently. This is known as a condensed mode operation. In it, one uses compounds that can be liquefied in the recycle condenser, and which are called Induced Condensing Agents (ICA). The use of ICA is extremely important from an industrial point of view. The injection of ICA can have many different physical effects at the level of the growing polymer particles. For instance, adding these compounds can cause changes in solubility and other physical properties, which can facilitate the transport of ethylene and hydrogen to the active sites of the catalysts. It is thus very important that the physical phenomena related to the sorption equilibrium of the monomer(s) and other species from the gas phase to the polymer phase, and their diffusion on the polymer matrix at the active sites should be accounted for. In addition to having an effect on the kinetics, these phenomena can also impact the structure of the polymer molecules and consequently qualify the characteristics of the polymer. Identifying the behavior of these phenomena under process conditions and control variables of the hydrogen/ethylene ratio and the comonomer/ethylene ratio with ICA are central objectives of this study. A series of ethylene homo- and co-polymerizations in the gas phase were carried out using a commercial Ziegler-Natta catalyst in the presence of ICA (propane, n-pentane, and n-hexane). We investigated the effect of temperatures, the partial pressure of ICA, hydrogen, and comonomers on the behavior of the polymerization. It was found that adding ICA significantly increased the reaction rate and average molecular weights at a given temperature. It was also unexpectedly observed that increasing the reactor temperature in the presence of an ICA actually led to a decrease in the overall reaction rate. These results were attributed to the socalled cosolubility effect. In reactions in the presence of different hydrogen concentrations, for an ICA/C2 ratio much larger than the H2/C2 ratio, the effect of ICA on ethylene solubility can counteract the decrease in average molecular weight caused by the presence of hydrogen. The impact of ICA on the rates of copolymerization reactions is more pronounced in the initial stages, losing strength due to the effect of the comonomer. Finally, an evaluation of the kinetics of crystallization under isothermal conditions for mixtures of different ICA:HDPE concentrations showed that the crystallization time is significantly higher for systems rich in ICA than for dry polymer
25

Towards the low temperature reduction of carbon dioxide using a polymer electrolyte membrane electrolysis cell / Vers le bas de la température de réduction du dioxyde de carbone en utilisant une cellule d'électrolyse à membrane électrolytique polymère

Soundiramourty, Anuradha 14 September 2015 (has links)
L’objectif principal de ce travail de thèse était d’évaluer les propriétés électro catalytiques de différents composés moléculaires vis-à-vis de la réduction électrochimique basse température du dioxyde de carbone, en vue d’applications dans des cellules d’électrolyse à électrolyte polymère solide. Après avoir mesuré les performances de métaux modèles (cuivre et nickel) servant de référence, nous avons testé les performances de quelques composés moléculaires à base de nickel. Le rôle catalytique de ces différents composés a été mis en évidence en mesurant les courbes intensité-potentiel dans différents milieux. Nous avons évalué l’importance de la source en hydrogène dans le mécanisme réactionnel. Les produits de réduction du dioxyde de carbone formés dans le mélange réactionnel ont été analysés par chromatographie en phase gazeuse. Nous avons ensuite abordé la possibilité de développer des cellules d’électrolyse à électrolyte polymère solide. Nous avons testé des cellules utilisant soit des anodes à eau liquide pour le dégagement d’oxygène, soit des anodes à hydrogène gazeux. L’utilisation de complexes moléculaires à base de nickel à la cathode a permis d’abaisser le potentiel de la cathode et de réduire le CO₂ mais la réaction de dégagement d’hydrogène reste prédominante. / The main objective of this research work was to put into evidence the electrocatalytic activity of various molecular compounds with regard to the electrochemical reduction of carbon dioxide, at low temperature, in view of potential application in PEM cells. First, reference values have been measured on copper and nickel metals. Then the performances of some molecular compounds have been measured. The electrochemical activity of these different compounds has been put into evidence by recording the current-potential relationships in various media. The role of a hydrogen source for the reduction processes has been evaluated. The formation of reduction products has been put into evidence and analyzed by gas phase chromatography. Then, a PEM cell has been developed and preliminary tests have been performed. PEM cells with either an oxygen-evolving anode or a hydrogen-consuming anode have been tested. Using nickel molecular complexes, it has been possible to lower the potential of the cathode and to reduce CO₂ but the parasite hydrogen evolution reaction was found to remain predominant.
26

Etude de la capture du CO2 par absorption physique dans les systèmes de production d'électricité basés sur la gazéification du charbon intégrée à un cycle combiné

Descamps, Cathy 01 June 2004 (has links) (PDF)
La volonté de réduction des émissions de gaz à d'effet de serre est à l'origine de l'étude de la capture du CO2 dans les systèmes de production d'électricité à base de gazéification du charbon intégrée à un cycle combiné. Une étude comparative des procédés de capture de CO2 retenus dans la littérature (MEA-MDEA, AMP, N-Méthyl- Pyrrolidone et méthanol) a conduit au choix de l'absorption physique par le méthanol. La simulation du fonctionnement de l'IGCC avec capture de CO2 a été réalisée à l'aide du logiciel Aspen Plus
27

Etude conformationnelle de peptides et protéines par mesure de mobilité ionique couplée à la spectrométrie de masse

Albrieux, Florian 02 July 2010 (has links) (PDF)
Ce travail de thèse porte sur l'analyse conformationelle de biomolécules en phase gazeuse. L'étude d'objets complexes en phase gazeuse permet de connaître les facteurs intrinsèques stabilisant leur structure. La première étape de mes travaux a été le couplage entre un appareil de mobilité ionique (IMS) et un appareil de spectrométrie de masse (MS). Nous avons simulé (SimIon) et développé différentes optiques ioniques fonctionnant à haute pression (entonnoirs à ions, piège ionique). Ces modifications expérimentales nous ont permis de commencer des études conformationnelles de biomolécules en phase gazeuse.Les premières expériences avaient pour objectif d'observer les facteurs stabilisants une structure secondaire sur des séries de peptides analogues. La première étude a été réalisée sur des séries de polyalalanines et de polyglycines de formules Arg(Ala)4XxxAla4Lys et Arg(Gly)4Xxx(Gly)4Lys, où Xxx est l'un des 20 acides aminés naturels. Nous nous sommes intéressés à l'influence de l'acide aminé central sur la conformation globale. Puis nous avons observés la stabilité de l'hélice de la partie transmembranaire de la protéine M2 du virus de la grippe A et de différents mutants. Ces études ont permit de montrer l'importance de la solvatation des charges en phase gazeuse.Enfin nous avons initié une étude sur le repliement des protéines en utilisant une protéine modèle, le lysozyme. Nous nous sommes plus particulièrement intéressés aux mécanismes de repliements en fonction du degré d'oxydation de cette dernière
28

Application de la pulvérisation cathodique à la chromatographie en phase gazeuse miniature Une nouvelle technique de dépôt collectif de la phase stationnaire pour la fabrication de micro colonnes sur puce: faisabilité, caractérisations, et applications pétrolières

Haudebourg, Raphaël 05 February 2014 (has links) (PDF)
Une nouvelle technique de dépôt de phases stationnaires solides pour la fabrication de micro colonnes de chromatographie en phase gazeuse a été proposée : pour dépasser les limites des phases stationnaires liquides conventionnelles (ou occasionnellement solides) en termes de rétention des composés très volatiles et/ou de fabrication par lots en salle blanche, une approche consistant en le dépôt direct de l'adsorbant sur le substrat par pulvérisation cathodique a été mise en œuvre. La méthode est par nature compatible avec le procédé de fabrication en salle blanche et industrialisable, et a montré de bons résultats en termes de précision. La séparation d'hydrocarbures volatiles a été rendue possible sur silice, alumine, graphite et magnésie. Différents types de colonnes (structure, phase stationnaire) ont été fabriquées sous la forme de puces en silicium de 2x2 cm², et leurs caractérisations thermodynamique et cinétique ont été réalisées. Des efficacités très satisfaisantes ont été obtenues (plus de 5700 plateaux, des hauteurs de plateau de 250 µm). La possibilité d'utiliser des colonnes à phase stationnaire déposée par pulvérisation cathodique pour l'analyse automatisée en temps réel d'hydrocarbures légers sur site pétrolier a été démontrée par l'implémentation d'un système de programmation en température de la puce et divers tests d'adaptabilité (haute température, gaz vecteur, humidité) : une séparation complète des alcanes linéaires C1-C9 en moins de 15 secondes a été obtenue, ainsi que des séparations de mélanges plus complexes (isomères, insaturés). Une application industrielle confidentielle a été brevetée et développée.
29

Conception, fabrication et caractérisation d'un capteur de conductivité thermique à base de nanofils de silicium / Design, fabrication and characterization of a silicon nanowire based thermal conductivity detector

Ruellan, Jérémie 06 May 2015 (has links)
Les nanofils semiconducteurs sont aujourd’hui le sujet de nombreuses recherches pour leurs propriétés physiques intéressantes. S’appuyant plus spécifiquement sur les propriétés thermiques des nanostructures, l’objectif de cette thèse est de démontrer la faisabilité d’un capteur de conductivité thermique conçu à partir de nanofils de silicium pour des applications en tant que jauge Pirani ou détecteur de gaz. Le travail réalisé aborde les questions posées par la réduction de taille des objets telles que l’augmentation du bruit ou la conduction thermique en régime de raréfaction et élabore des solutions à ces problématiques. Le manuscrit aborde l’ensemble des étapes nécessaires à la réalisation d’un capteur, à savoir la conception des dispositifs, s’appuyant sur une étude détaillée du comportement physique des objets utilisés, la fabrication sur plaque 200mm de ces capteurs par la salle blanche du CEA-Leti en ayant recours aux techniques classiques de la microélectronique et enfin leur caractérisation en tant qu’instrument de mesure de pression (jauge Pirani) ou en tant que capteur de concentration de gaz. Le travail réalisé s’intègre dans un projet plus global de réalisation d’un système de détection de gaz portatif pour l’analyse de l’air ou de l’eau / Semiconducting nanowires are nowadays the topic of numerous research for their interesting physical properties. Relying more specifically on the thermal properties of nanostructures, the purpose of this thesis is to demonstrate the feasibility of a thermal conductivity detector based on silicon nanowires for pressure sensing (Pirani gauge) or gas detection. The work presented herein addresses the questions raised by the reduction of the objects size such as the increase of the noise or the thermal conduction in a rarefied gas and tries to bring a solution to those problematics. This work deals with all the steps required for the realization of such devices. That is, the design and simulation of the sensor, based on a detailed study of the physical behavior of the objects, the fabrication of such devices on 200mm wafers by the CEA-Leti cleanroom using standard microelectronics processes and finally their characterization as a pressure sensor and gas detector. The work presented here is part of a wider project that aims at developing of a portable gas detection system for air or water analysis.
30

Flaveur du caramel : impacts de la fraction volatile odorante et de la fraction non volatile sur la perception / The caramel flavour : impacts of the volatile and the non-volatile fraction on perception

Paravisini, Laurianne 10 December 2013 (has links)
L’objectif de cette étude est d’étudier l’impact de la fraction volatile odorante et de la fraction non-volatile sur la perception de la flaveur du caramel. Dans la première étape, la fraction volatile du caramel a été analysée par Chromatographie en Phase Gazeuse couplée à l’Olfactométrie (GC/O), par GC couplée à la Spectrométrie de Masse (GC/MS) et par heart-cutting MDGC. Les résultats mettent en évidence une centaine de composés volatils et démontrent la richesse aromatique du caramel. L’objectif de la deuxième étape était d’évaluer la contribution de ces composes volatils à la typicité odorante du caramel. Des études ont montré que l’intensité odorante n’était pas suffisante pour évaluer l’impact des composés. Ce travail de thèse propose une approche originale de recombinaison d’odeur à partir de composés triés selon leur qualité odorante. Les résultats montrent que la typicité odorante caramel est le fruit d’un équilibre entre les notes caramel, fruité, fruits secs, végétal, animal, grillé, floral et piquant. Des tests d’addition, d’omission et d’un plan d’expérience factoriel complet ont démontré l’existence d’interactions perceptives. L’objectif de la dernière étape était d’étudier l’impact de la fraction non volatile sur la perception de la flaveur du caramel. L’étude de la libération de composés d’arôme in vitro par analyses SPME/GC/MS dans différentes matrices non volatiles démontre l’existence d’interactions physico-chimiques entre les composés d’arôme et les macromolécules non volatiles. Ces premiers résultats laissent supposer que la fraction non volatile est susceptible de moduler la perception de la flaveur / The aim of this study was to investigate the impact of the volatile odorant fraction and the non-volatile matrix on the perception of the caramel flavour. The first step focused on the analytical characterization of the volatile odorant fraction of aromatic caramel thanks to Gas Chromatography coupled to Olfactometry (GC/O), GC/Mass Spectrometry (GC/MS) and heart-cutting MDGC/MS/O. Results highlighted the presence of more than one hundred compounds and demonstrated the complexity of the caramel volatile fraction. The objective of the second step was to understand the contribution of odorant compounds identified to the caramel aroma typicality. Literature shows that odour intensity is not sufficient to evaluate the impact of compounds on the aroma. This thesis proposed an original approach to carry out the aroma recombination by taking into account odour qualities. Results showed that the caramel typicality results from a complex balance between caramel, fruity, vegetal, sharp, nutty, floral, roasted and animal odours. Omission, addition tests and a 24 factorial design showed the existence of perceptive interactions. The third step focused on studying the impact the macromolecules that constitute the non-volatile fraction on the perception of caramel flavour. In vitro aroma release was followed by SPME/GC/MS in different matrices varying in non-volatile composition. Results evidence physico-chemical interactions between aroma and macromolecule of the non-volatile fraction. Those preliminary results suggest that the non-volatile matrix is able to impact the flavour perception

Page generated in 0.0744 seconds