• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 102
  • 2
  • 2
  • 1
  • Tagged with
  • 107
  • 82
  • 30
  • 24
  • 21
  • 19
  • 17
  • 17
  • 17
  • 16
  • 15
  • 11
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo da interação entre porfirinas e eumelanina sintética / Study of porphyrin-synthetic eumelanin interaction

Dilcelli Soares 16 December 2005 (has links)
Foram investigadas através da técnica de absorção eletrônica Uv-Vis e emissão de fluorescência a interação entre uma série de porfirinas e zinco-porfirinas com o polímero de eumelanina sintética obtida pela auto-oxidação da L-DOPA (dihidroxi-fenilalanina). Ocorre a formação de dois complexos na interação entre as porfirinas catiônicas e a eumelanina. Um complexo mais fraco em concentrações mais baixas e intermediárias de eumelanina, e um complexo mais forte em concentrações maiores. Estes complexos podem ser observados pelas variações obtidas nos espectros de absorção em função da concentração da melanina. A eumelanina suprime eficientemente a fluorescência das porfirinas catiônicas, em um processo de supressão por esfera de ação. Este processo ocorre particularmente para os complexos fracos entre a porfirina e a eumelanina, podendo ser inferido pela natureza de polieletrólito da eumelanina que deve apresentar uma ampla superfície de contato carregada negativamente, facilitando a orientação das porfirinas em uma disposição planar em relação ao polímero. A determinação das constantes de supressão estáticas aparentes (KEA) mostra que os substituintes alquílicos influem consideravelmente na formação destes complexos com a eumelanina. As diferentes interações são devidas aos fatores estruturais tais como dimensão da porfirina, polarização dos substituintes e formação de interações de natureza hidrofóbica. As zinco-porfirinas são de forma geral menos suprimidas que as bases livres. Este comportamento pode ser uma evidencia da aproximação planar em relação ao polímero da melanina, uma vez que zinco porfirinas apresentam moléculas de água ligadas axialmente, logo estas moléculas coordenadas axialmente impediriam uma aproximação mais efetiva. Foi realizado um estudo da formação de filmes baseados na técnica de auto-montagem eletrostática entre as porfirinas e a melanina utilizando como substrato o vidro. Observa-se que a adsorção das porfirinas em vidro é diferenciada sendo a TBzPyP a base livre que apresenta a maior adsorção. Pelos espectros de emissão dos filmes de porfirina em vidro foi possível verificar que alguns derivados interagem com uma participação mais efetiva dos piridínios que outros em que a interação é menos direcionada. Nos filmes porfirina melanina também é observada a supressão de fluorescência da porfirina. A diferença na magnitude de supressão nos filmes sugere que estes derivados possam ser utilizados em sistemas de diagnóstico relacionados à detecção de tumores melanóticos. Em um estudo paralelo, foram investigadas as propriedades de fotoisomerização de grupos azobenzênicos coordenados axialmente a uma ftalocianina de Silício(IV). Este sistema apresenta fotoisomerização E-Z e isomerização térmica e sensibilizada para o processo Z-E. As conversões E-Z e Z-E seguem uma cinética de primeira ordem, sendo o processo térmico Z-E cerca de dez vezes mais lento que o fotoquímico E-Z. A intensidade de fluorescência da ftalocianina é dependente do estado de isomerização dos grupos axiais, sendo que a forma E apresenta maior emissão de fluorescência que a forma Z. Portanto este sistema se constitui em um dispositivo molecular do tipo “on-off”, onde a intensidade de fluorescência pode ser controlada por um estímulo externo, no caso o comprimento de onda de excitação para a reação E-Z direta ou Z-E sensibilizada. / In this work we have investigated the interaction between a series of cationic porphyrins and zinc-porphyrins and the synthetic eumelanin polymer obtained by the auto-oxidation of L-DOPA (dihidroxy-phenylalanine) by means of UV-Vis and fluorescence emission techniques. Weak and strong porphyrin-melanin complexes are formed, and the evolution from weak to strong complexes can be monitored by the UV-Vis changes in the pophyrin spectra as the melanin concentration increases. The porphyrin fluorescence emission is quenched efficiently by eumelanin in a “quenching sphere of action” mechanism. This quenching sphere of action process is mainly observed for the weak complexes, and can be rationalized considering the polyelectrolyte nature of the eumelanin polymer which provides a broad contact area coated negatively, that enables a planar approximation of the porphyrins. The apparent static quenching constants (KEA) show that the nature of the alkyl substiutents markedly influences the complex formation. Total porphyrin size, different polarization induced by substituents and specific hydrophobic interactions are probably responsible for the different porphyrin – melanin association, which in turn reflects in the quenching properties of each particular porphyrin - melanin complex. The corresponding Zinc-porphyrins are less efficiently quenched by eumelanin, probably due the fact this molecules are axially coordinated by a water molecule, precluding a more close approximation between zinc-porphyrin and the eumelanin polymer. Electrostatically self-assembled films of porphyrins and eumelanin on glass have been studied. Different porphyrin adsorption on glass were observed, and TBzPyP derivative shown the highest adsorption in the investigated porphyrin series. Fluorescence emission suggests different interaction properties of the adsorbed pophyrin on glass, with specific pyridinium participation for some porphyrin derivatives. Fluorescence quenching of the porphyrins is observed in porphyrin – melanin films. The differences observed in the quenching for each derivative suggest a possible application of these compounds for diagnostic procedures related to melanotic tumors. In a complementary study, have been investigated the photoisomerization properties of a Si(IV)-phthalocyanine axially coordinated by azobenzene groups. Photochemical E-Z and thermal and sensitized Z-E isomerization processes were observed. Both E-Z photochemical and Z-E thermal follow first-order kinetics. Z-E process as expected is considerably slower than E-Z. The pthalocyanine emission is dependent on the isomerization state of the apendent azobenze groups, and the E form is more emissive than the Z form. This system can be considered a molecular device since the emission properties of the phthalocyanine moiety can be modulated by the isomerization state of the axially coordinated azoarenes, creating an on-off (E-Z states) fluorescence signal, and differently from other reported systems the recovery of the initial state does not depend only on the rate of the thermal reaction, since it can be controlled by a sensitized mechanism. This system seems promising taking into account the stability of the axially coordinated moieties, the greater versatility in the achievement of the desired isomerization state and the broad spectral region considering both direct and sensitized excitation.
82

Interações moleculares na adesão celular em suportes sólidos e o efeito de fotossensibilizadores porfirínicos / Molecular interactions in cell adhesion on solid substrates and the effect of porphyrinic photosensitizers

Patrícia Araújo dos Santos 28 March 2013 (has links)
A adesão celular está ligada à formação e disseminação de metástases, a principal causa de óbito de pacientes diagnosticados com câncer. O objetivo deste trabalho foi investigar in vitro o efeito de fotossensibilizadores na adesão celular. Foram utilizadas porfirinas comerciais (PpIX, CPpI, TSPP, TMPyP e Zn(II)TMPyP) e um fotossensibilizador sintetizado através da ligação de poli-L-lisina à protoporfirina IX (PLLPpIX). A adesão celular foi estudada por RICM, técnica que permite quantificar a área de contato entre uma célula e um substrato por binarização das imagens digitais utilizando limiares apropriados. A técnica foi padronizada e revelou dois regimes de adesão celular: um limitado e outro não limitado pela quantidade de proteína de adesão adsorvida na superfície. Neste último foi observada lise celular. Todos os fotossensibilizadores estudados foram capazes de aumentar a adesão celular na ausência de irradiação comparados ao controle sem fotossensibilizador, o que não havia sido observado nos ensaios de resistência à tripsinização normalmente utilizados para estudar o efeito de fotossensibilizadores na adesão celular. Quanto maior a anfifilicidade do fotossensibilizador, maior foi o efeito na adesão, o que é explicado pela capacidade das moléculas em se intercalarem na membrana, mudando a sua rigidez. Este aumento da adesão no escuro correlaciona com a diminuição da migração segundo ensaios de ferida. A análise do padrão de expressão de integrinas na superfície celular revela que o aumento da adesão correlaciona com o aumento na expressão de αV. Quando os fotossensibilizadores estão concentrados na região perimembranar (1 minuto de incubação) e as células são irradiadas, há um aumento da adesão em relação ao controle sem fotossensibilizador, mas uma diminuição em relação ao controle tratado com o fotossensibilizador e não irradiado, o que implica que a PDT leva a uma diminuição da adesão celular e não a um aumento como reportado na literatura. Com 3h de incubação, PLLPpIX impede a adesão celular, enquanto PpIX praticamente não muda a adesão comparado ao controle não irradiado. Esta ausência do efeito da irradiação sugere que a PpIX afeta a adesão celular principalmente devido a sua intercalação na membrana e não devido à formação de espécies reativas. Com 3h de incubação os fotossensibilizadores não se encontram na membrana e, portanto, o efeito na adesão celular é indireto e também não está relacionado à diferenças na eficiência de internalização. O comportamento observado deve ter relação com diferenças de citolocalização. Outro processo que pode alterar a adesão celular é a oxidação das proteínas do soro fetal bovino. Como observado nos estudos de fotossensibilização de células, PLLPpIX foi capaz de impedir a adesão celular, diferentemente da PpIX. A maior eficiência da PLLPpIX foi associada a presença do polímero, o qual força por questões estéricas que a interação da PLLPpIX com a albumina, o componente majoritário do soro, fique restrita à superfície da proteína, deixando o fotossensibilizador disponível para interagir com o oxigênio molecular e gerar oxigênio singlete. Assim, a funcionalização com um polímero tornou a PpIX capaz de modular a adesão celular tanto agindo dentro da célula quanto na matriz extracelular. / Cell adhesion is associated to the formation and spread of metastasis, the leading cause of death in cancer patients. The aim of this study was to investigate, in vitro, the effect of photosensitizers in cell adhesion. Five commercial porphyrins (PpIX, CPpI, TSPP, TMPyP e Zn(II)TMPyP) and Protoporphyrin IX covalently tethered to poli-L-lysine (PLLPpIX) were used. Cell adhesion was mainly studied by RICM, a technique that allows quantifying the contact area between a cell and a substrate for binarization of digital images using appropriate thresholds. The technique was standardized and disclosed two systems for cell adhesion: a system limited by the amount of adhesion proteina adsorbed on the surface and another one no limited, in which cell lysis was observed. All photosensitizers were able to enhance cell adhesion in the absence of irradiation compared to control without photosensitizer, which had not been observed in the trypsinization resistance tests usually used to study the effect of photosensitizers in cell adhesion. The greater the amphiphilicity of the photosensitizer, the greater was the effect on cell adhesion. This is explained by the ability of molecules to fit in the membrane, changing its tension. This increased adhesion correlates with the decrease in migration according to wound healing assays. Analysis of the integrin expression pattern on cell surface reveals that increased adhesion correlates with increased expression of alpha V. When photosensitizers are concentrated in the perimembranar region (1 minute of incubation) and cells are irradiated, there is an increase in adhesion when compared to control without photosensitizer, but a decrease relative to controls treated with the photosensitizer without irradiation, implying that PDT leads to a reduction of cell adhesion and not to an increase as reported in the literature. With 3h of incubation PLLPpIX prevents cell adhesion, while PpIX practically does not change the adhesion compared to dark control. This lack of effect of irradiation suggests that PpIX affects cell adhesion primarily because of its intercalation into the membrane and not due to the formation of reactive species. With 3h of incubation the photosensitizers are not on the membrane and therefore the effect on cell adhesion is indirect and it is not also related to differences in uptake efficiency. The observed behavior must be related to differences in subcellular localization arising from differences in molecular structure. Another process that can alter the cell adhesion is serum protein oxidation. As noted in the studies with cells, photosensitization of serum with PLLPpIX (but not with PpIX) was capable of preventing cell adhesion. The greater efficiency of PLLPpIX was associated with the presence of the polymer, which, by the steric hindrance, forces that interaction of PLLPpIX with albumin, the major serum component, is restricted to the protein surface, leaving the photosensitizer available to interact with molecular oxygen and generate singlet oxygen. Thus, the functionalization of a polymer has turned PpIX capable of modulating cell adhesion by acting both within and outside (in extracellular matrix) the cell
83

Estudo das interações de moléculas orgânicas com imunoglobulinas G / Study of organic molecules interactions with immunoglobulin G

Bezerra, Fabio de Castro 30 April 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-16T12:31:22Z No. of bitstreams: 2 Dissertação - Fábio de Castro Bezerra - 2015.pdf: 1134192 bytes, checksum: 61d0dd74a6363dfdeccf24d48ee39e2d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-10-16T12:32:52Z (GMT) No. of bitstreams: 2 Dissertação - Fábio de Castro Bezerra - 2015.pdf: 1134192 bytes, checksum: 61d0dd74a6363dfdeccf24d48ee39e2d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-10-16T12:32:52Z (GMT). No. of bitstreams: 2 Dissertação - Fábio de Castro Bezerra - 2015.pdf: 1134192 bytes, checksum: 61d0dd74a6363dfdeccf24d48ee39e2d (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-04-30 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / (Sem resumo em outra língua) / Este trabalho teve por objetivo estudar a interação entre moléculas orgânicas e anticorpos visando seu uso em sistemas de entrega de fármacos e diagnóstico fluorescente. Foram investigadas moléculas orgânicas de porfirinas e anticorpos reativos a Herpesvírus bovino, micro-organismo amplamente disseminado em rebanhos de corte e leite. Para o desenvolvimento deste projeto foram empregadas técnicas espectroscópicas de absorção UV/Vis, emissão fluorescente e espalhamento ressonante. Os resultados obtidos apresentaram indícios de que a ligação entre as porfirinas e os anticorpos ocorre. As constantes de ligação associadas à essa interação sugeriram alta afinidade das porfirinas pelos anticorpos. As investigações da conformação dos anticorpos indicaram que a sua estrutura enovelada não é significativamente afetada pelas porfirinas e os estudos de Transferência de Energia Ressonante de Förster sugeriram que esse mecanismo pode ser o principal responsável pela supressão da fluorescência dos anticorpos pelas porfirinas.
84

Síntese e aplicação de um poli(arenilenovinileno) derivado de [2,1,3]-benzotiadiazol, tiofeno e fluoreno em narizes eletrônicos e dispositivos magnetorresistivos / Synthesis and application of a poli(arylenevinylene) derived from [2,1,3]-benzothiadiazole, thiophene and fluorene in electronic noses and magnetoresistive devices

Carlos Henrique Alves Esteves 01 February 2013 (has links)
O objetivo sintético do presente trabalho é a síntese, caracterização e aplicação do polímero conjugado inédito de baixa Egap, poli(9,9-n-dioctil-2,7-fluorenilenovinilenoalt- 4,7-dibenzotiadiazol-2,5-tiofeno) (PF-BTB). A rota sintética proposta envolve 10 passos, dentre os quais destacam-se reações como a de Wittig e acoplamentos de paládio (Stille e Heck). A caracterização da molécula envolveu as técnicas de RMN de 1H, espectroscopias de infravermelho, UV-VIS e fluorescência, voltametria cíclica, análises térmicas (TGA e DSC) e cromatografia por permeação em gel. A primeira aplicação do polímero se deu na construção de um nariz eletrônico capaz de identificar com ótima precisão três variedades de tabaco (Burley, Flue Cured e Oriental), além de oito diferentes marcas comerciais de cigarro. Esses estudos, além da aplicação prática, serviram para mostrar a eficiência de um tipo novo de sensor para narizes eletrônicos, composto por um mesmo polímero condutor dopado com diferentes porfirinas, denominado sensor híbrido. Por fim, filmes finos do polímero PF-BTB, depositados sobre eletrodos de ouro, tiveram suas propriedades magnetorresistivas testadas em diferentes condições, apresentando valores maiores que 40%, o que é considerado muito alto para esse tipo de fenômeno em filmes poliméricos. / The aim of this work is the synthesis, characterization and application of a novel low Egap conjugated polymer, poly(9,9-n-octyl-2,7-fluorenevinylene-alt-4,7- benzothiadiazole-2,5-thiophene) (PF-BTB). The synthetic pathway comprises 10 steps, involving reaction such as Wittig\'s and palladium cross-couplings (Heck\'s and Stille\'s). The molecule was characterized by the following techniques: 1H NMR, spectroscopic analyses (FTIR, UV-VIS and fluorescence spectroscopy), cyclic voltammetry, thermal analyses (TGA and DSC) and gel permeation chromatography. The polymer was first used to build an electronic nose, which successfully identified three tobacco types (Burley, Flue Cured and Oriental) with high accuracy. The same system could also identify eight different cigarette brands. Besides this practical application, the experiments were designed to show the power of a new sensor type, composed by a single conductive polymer doped with different porphyrins, a composite sensor. Finally, thin films of PF-BTB deposited onto gold electrodes had their magnetoresistive properties tested under different conditions. The material showed magnetoresistance values higher than 40%, which is considered outstanding for this kind of polymeric films.
85

Mn(III)porfirinas sintéticas como modelos químicos do Citocromo P-450: a O-desalquilação oxidativa de aril éteres substituídos como modelos de drogas por iodosilbenzeno / Synthetic Mn(III)porphyrins as cytochrome P-450 mimic: oxidative O-dealkylation of aryl substituted ethers by iodosylbenzene as drug models

Carlos Alberto Felipucci Neto 03 October 2007 (has links)
Reações de O-desmetilação oxidativa estão entre as várias oxidações realizadas pelas enzimas do citocromo P-450. Entretanto, poucos estudos de O-desmetilação catalisadas por enzimas do citocromo P-450 ou modelos químicos baseados em metaloporfirinas sintéticas têm resultado em dúvidas acerca do mecanismo da O-desmetilação destes compostos orgânicos. Neste trabalho, foi estudada a O-desmetilação oxidativa, com PhIO, do benzil metil éter e alguns de seus derivados para substituídos (com os grupos doadores de elétrons -OCH3 e -CH3 e os grupos retiradores -NO2 e -Cl) catalisada pelas Mn(III)P [Mn(TPP)]Cl, [Mn{T(4-N-MePy)P}](PF6)5, [Mn(TMP)]Cl, [Mn(TDCSPP)]Cl e [Mn(TFPP)]Cl para verificar o efeito destes diferentes catalisadores na conversão e seletividade de produtos da O-desmetilação oxidativa e avaliar o efeito dos diversos substituintes citados no mecanismo de O-desalquilação. Inicialmente, realizou-se o estudo das oxidações catalíticas do metil benzil éter. Todas as reações catalisadas pelas MnP se mostram seletivas, sendo que o benzaldeído foi o produto comum a todas as oxidações. A melhor condição encontrada foi 1:50:1224 (catalisador/oxidante/substrato). Em relação às reações com os substratos contendo os substituintes na posição -para, as reações de oxidações catalíticas do p-metóxibenzil metil éter por PhIO não se mostraram tão seletivas quanto as do metil benzil éter, mostrando claramente que o grupo metóxi alterou a reatividade do aril éter original. Mesmo assim, o p-metoxibenzaldeído ainda foi o produto principal, sendo a conversão ao álcool p-metoxibenzílico observada em escala menor. Já com o substrato p-nitrobenzil metil éter, novamente o efeito provocado pelo substituinte na posição para no anel benzênico pôde ser percebida na distribuição final dos produtos, sendo que houve seletividade total para a formação de p-nitrobenzaldeído em detrimento ao álcool p-nitrobenzóico. Em relação aos dois últimos substratos da série proposta, metil p-metilbenzil éter e metil p-clorobenzil éter, de um modo geral, as reações realizadas com o p-clorobenzil metil éter não se mostraram tão seletivas quanto as do metil p-nitrobenzil éter, mostrando que o grupo cloro aumentou a reatividade do cloroéter em relação ao éter com o substituinte nitro- original. Mesmo assim, o p-clorobenzaldeído foi o produto principal, sendo a conversão ao álcool p-clorobenzílico observada em menor escala. Em relação às reações de oxidação do p-metilbenzil metil éter, observou-se que os resultados experimentais são semelhantes aos encontrados para o metil benzil éter. Esses resultados corroboram o principal mecanismo proposto para os sistemas modelo do citocromo P-450 que envolve abstração inicial do átomo de hidrogênio, o mecanismo por recombinação de oxigênio. / O-dealkylation oxidative reactions are among the several oxidations accomplished by the cytochrome P-450 enzymes. However, few studies on O-dealkylation catalyzed by such enzymes or chemical models based on synthetic metalloporphyrins have resulted in doubts concerning the mechanism of these reactions involving organic compounds. In this work, we studied the oxidative O-dealkylation by PhIO of benzyl methyl ether and some of its para-substituted derivatives (with the electron donor groups -OCH3 and -CH3 and the electronwithdrawing groups -NO2 and -Cl) catalyzed by the following Mn(III)P: [Mn(TPP)]Cl, [Mn{T(4-N-MePy)P}] (PF6)5, [Mn(TMP)]Cl, [Mn(TDCSPP)] Cl, and [Mn(TFPP)]Cl. Our aim was to verify the effect of these different catalysts on the conversion yields and product selectivity, as well as evaluate the effect of the several substituents on the ether on the O-dealkylation mechanism. We initially studied the catalytic oxidation of methyl benzyl ether. All the reactions catalyzed by the various MnPs were selective, and benzaldehyde was the product common to all oxidations. The best reaction condition was catalyst/oxidant/substrate molar ration = 1:50:1224. As for the reactions with the substituted substrates, the catalytic oxidation of p-methoxybenzyl methyl ether by PhIO was not as selective as the ones of methyl benzyl ether, clearly showing that the methoxy group affects the reactivity of the original aryl ether. Nevertheless, p-methoxybenzaldehyde was still the main product, being the conversion to p-methoxybenzylic alcohol observed in minor amount. With the substrate p-nitrobenzyl methyl ether, the effect of the electronwithdrawing substituent in the para- position of the aromatic ring could be observed in the final product distribution once again, and total selectivity toward the formation of p-nitrobenzaldehyde to the detriment of p-nitrobenzoic alcohol was observed. In relation to the two last substrates of the proposed series, the methyl p-methylbenzyl and methyl p-chlorobenzyl ethers, the reactions accomplished with p-chlorobenzyl methyl ether were not as selective as the ones carried out with methyl p-nitrobenzyl ether, showing that the chloro group increased the reactivity of the chloro-ether in relation to the ether with the original nitro- substituent. Even so, p-chlorobenzaldehyde was the main product, being the conversion to the p-chlorobenzylic alcohol observed in smaller amount. Concerning the oxidation reactions of p-methylbenzyl methyl ether, the experimental results were similar to those obtained in the case of methyl benzyl ether. These results corroborate the main mechanism proposed for the cytochrome P-450 model systems, which involves initial hydrogen atom abstraction, followed by oxygen rebound.
86

DDesenvolvimento de eletrodos modificados e métodos analíticos / Development of modified electrodes and analytical methods

Carla Maria Nunes Azevedo 16 April 1999 (has links)
Neste trabalho foram desenvolvidos eletrodos modificados e procedimentos para a sua utilização na determinação de diversas espécies químicas de interesse analítico, dentre as quais sulfito, ácido ascórbico, nitrito, dopamina, NADH e peróxido de hidrogênio. Foram realizados estudos envolvendo eletrodos de carbono vítreo modificados com filmes contendo uma única metaloporfirina tetrarrutenada (catiônica) e aplicações analíticas destes sensores associando-os à análise por injeção em fluxo (FIA). Estes eletrodos apresentaram efeitos catalíticos sobre a oxidação de vários analitos, intensificando o sinal de corrente e deslocando seus picos de oxidação para a região de oxidação dos átomos de Ru(II) à Ru(III), sítios ativos das porfirinas. Contudo, para a obtenção de sensores estáveis, foi necessária a utilização de uma elevada concentração do contra-íon trifluorometanossulfonato em solução, prevenindo a gradual solubilização do filme modificador. Tal dificuldade foi contornada recobrindo-se os eletrodos com filmes laminares contendo simultaneamente pares de porfirinas catiônicas e aniônicas. Estes sensores apresentaram ação catalítica igual aos eletrodos recobertos por uma única porfirina, uma vez que os sítios ativos continuaram sendo os átomos de rutênio. Esta nova geração de eletrodos modificados exibiu excelente desempenho tanto em análises de amostras sintéticas, quanto de amostras reais (sulfitos em vinhos e ácido ascórbico em sucos e medicamentos). Os sensores modificados com metaloporfirinas apresentaram excelente sensibilidade (limites de detecção entre 10-8 e 10-6 mol L-1) e minimizaram os efeitos de envenenamento da superfície, além de serem de fácil preparo. No presente trabalho também foram realizados estudos preliminares envolvendo eletrodos de pasta de carbono dopados com o óxido misto de NdNiO3. Estes destacaram-se, principalmente, por antecipar a oxidação de peróxido de hidrogênio para 0,00 V em meio alcalino. Análises utilizando o sistema BIA (Batch Injection Analysis) possibilitaram a detecção de H2O2 em concentrações da ordem de 10-6 mol L-1. / In this work modified electrodes were developed and proceedings for their utilization in the detection of a variety of species with analytical importance, such as sulfite, ascorbic acid, nitrite, dopamine, NADH and hydrogen peroxide were investigated. During the studies, modified electrodes with films containing one porphyrin were developed and analytical applications with these sensors were done in association with flow injection analysis (FIA). These electrodes presented interesting catalytic properties for the oxidation of many species, increasing the current signal and changing the oxidation peaks of the analytes to the Ru(II)/(III) oxidation region. In these studies, it was necessary high concentrations of trifluormethanesulfonate in solution to avoid the gradual solubilization of the film from the electrode surface. This difficulty was surpassed by developing of modified electrodes with laminar films containing simultaneously two porphyrins, one cationic and other anionic. This new geration of modified electrodes exhibited excellent performance for analysis of the synthetic samples as much as real samples (sulfites in wines and ascorbic acid in juices and medicaments). The metalloporphyrins modified electrodes presented very high sensitivity (detection limit between 10-8 and 10-6 mol L-1), were able to minimize the poisoning effects of the sensor and are very easy to prepare. In this work were also performed some preliminary studies involving carbon paste electrodes doped with NdNiO3 oxide, which stand out specially due to anticipate the oxidation of hydrogen peroxide to 0.00 V in alkaline media. Analysis using batch injection analysis (BIA) makes possible the detection of H2O2 in the 10-6 mol L-1 level.
87

Desenvolvimento de sensores eletroquímicos associados a batch injection analysis (bia) para aplicações analíticas / Development of electrochemical sensors associated with batch injection analysis (BIA) for analytical applications

Maria do Socorro Maia Quintino 11 December 2003 (has links)
Sensores eletroquímicos, constituídos de substratos metálicos modificados por metaloporfirinas e de superfícies livres de agentes modificadores, foram desenvolvidos com vistas a aplicações analíticas. Eletrodos de cobre apresentaram ação eletrocatalítica para a oxidação de ácido acetilsalícílico, com possível participação de Cu(III) como mediador na reação de transferência de elétrons. A oxidação de salbutamol sobre eletrodos de carbono vítreo foi conduzida em solução fortemente alcalina, condição na qual a determinação do analito foi viabilizada devido à eliminação de problemas associados à presença de interferentes e ao envenenamento do eletrodo. Superfícies de carbono vítreo, modificadas por adsorção e por eletropolimerização de porfirinas tetrarrutenadas de cobalto (CoTRP) e de níquel (NiTRP), respectivamente, demonstraram a versatilidade que tais compostos oferecem quanto ao modo de recobrimento do sensor, levando à obtenção de efeitos atrativos, tais como eletrocatálise e prevenção de envenenamento. Filmes de CoTRP, cujos sítios ativos são atribuídos ao par redox Ru(III)/Ru(II), mostraram-se úteis na determinação de acetaminofen, facilitando a reação de transferência de elétrons e protegendo o eletrodo contra o envenenamento. A atividade eletrocatalítica de eletrodos modificados por NiTRP, baseados em filmes com centros redox Ni(III)/Ni(II), foi evidente para a oxidação de glicose e de outros compostos orgânicos em meio alcalino. Os sensores desenvolvidos foram adaptados ao sistema BIA (batch injection analysis) para a determinação amperométrica dos analitos em amostras de produtos farmacêuticos. O método BIA mostrou-se adequado para as análises, sendo possível obter sinais transientes de corrente, boa estabilidade e alta dispersão. Os resultados bastante satisfatórios demonstram a aplicabilidade dessa técnica em análises em que alta velocidade e boa precisão são freqüentemente requisitadas. / Electrochemical sensors based on bare and modified electrodes were developed for analytical purposes. Copper electrodes exhibited electrocatalytical action for the acetylsalicylic acid oxidation, with the participation of Cu(III) species as electron-transfer mediators. The salbutamol oxidation at glassy carbon electrodes was carried out in strongly alkaline solution. In such a condition, interferences and electrode fouling were eliminated and the analyte quantification was enabled. Glassy carbon surfaces modified via adsorption and electropolymerization of tetraruthenated cobalt (CoTRP) and nickel (NiTRP) porphyrins, respectively, displayed the usefulness of these compounds for the obtainment of electrocatalysis and fouling prevention. Films based on CoTRP, from what Ru(III) are the active sites, were applicable to acetaminophen analysis by facilitating the electron transfer process and protecting the electrode against fouling. The electrocatalytical activity of modified NiTRP electrodes, based on films with Ni(III)/Ni(II) redox centers, was evident for glucose oxidation and other organic compounds. The sensors were coupled to the BIA (batch injection analysis) system for the amperometric determination of the analytes in pharmaceutical products. BIA was suitable because it presented sharp current response peaks, excellent stability and rapid washing out. The satisfactory results demonstrate the feasibility of such technique for fast analyses with good precision.
88

Estudo da imobilização de porfirinas em sílica nanoparticulada e da sua interação com oxigênio e ferro: possíveis aplicações biomédicas e analíticas / Study of the immobilization of porphyrins in silica nanoparticles and their interaction with oxygen and iron: possible biomedical and analytical applications

Paulo Rogerio da Silva 17 December 2008 (has links)
O presente estudo teve por objetivo desenvolver metodologias para imobilização de sondas moleculares fluorescentes em matrizes de sílica de tamanho controlado, bem como estudar a interação das sondas livres e imobilizadas com oxigênio e ferro. A classe de fluoróforos escolhida foi a das porfirinas, que apresentam baixa solubilidade em água e têm seu uso limitado, apesar de apresentarem pelo menos duas propriedades interessantes: (i) interagem com oxigênio formando oxigênio singlete, sendo candidatas a drogas para terapia fotodinâmica, e (ii) têm sua fluorescência suprimida ao complexarem metais, podendo atuar como sondas fluorescentes. A imobilização de porfirinas em esferas de sílica de tamanho inferior a 100 nm foi realizada através de um processo sol-gel ou pelo uso de microemulsões. O método sol-gel exigiu a modificação prévia da molécula da porfirina com reagente organosilano e resultou em esferas na faixa de 70 nm. O método da microemulsão dispensou a modificação da porfirina e resultou em esferas na faixa de 30 nm, muito estáveis em água. Os fluoróforos imobilizados preservaram suas propriedades óticas e a sua capacidade de gerar oxigênio singlete. Os estudos envolvendo a detecção de oxigênio singlete foram realizados pelo método físico direto, a partir do registro da fosforescência característica no infravermelho-próximo, e pelo método químico indireto usando a sonda 1,3difenilisobenzofurano. O tempo de vida do oxigênio singlete obtido quando uma suspensão, em acetonitrila, de esferas de sílica carregadas com porfirinas foi excitada em 532 nm foi de 52 &#181;s e está de acordo com o valor determinado para uma solução padrão contendo azul de metileno sob as mesmas condições. As porfirinas imobilizadas em sílica apresentaram eficiência de geração de oxigênio singlete similar ou até superior ao rendimento quântico das porfirinas livres. Após estudos concluiu-se que a elevada geração de oxigênio singlete pode ser atribuída a mudanças no equilíbrio monômero-dímero após a imobilização das porfirinas na matriz de sílica. O emprego das porfirinas imobilizadas em esferas de sílica como sondas fluorescentes para detecção de ferro também foi investigado. Estudos da interação da hematoporfirina IX livre e imobilizada com ferro apresentaram sítios de forte e fraca interação de acordo com a faixa de concentração de ferro utilizada. A supressão da fluorescência da Hp IX livre e imobilizada em sílica obedece a um comportamento linear na faixa de concentração de ferro de 0 a 60 &#181;M. Portanto, a imobilização de porfirinas em nanoesferas de sílica permitiu a dispersão de porfirinas insolúveis em água e manteve as moléculas acessíveis ao oxigênio molecular e aos íons ferro, preservando suas propriedades e ampliando a possibilidade de aplicações. / The present study is focused on developing methodologies for the immobilization of fluorescent molecular probes in size controlled silica matrixes, and studying the interactions of free and entrapped molecules with molecular oxygen and iron. This study was based on porphyrins, a class of compounds with low solubility in water and limited use, but with at least two very interesting properties: (i) interaction with molecular oxygen to yield singlet oxygen, potential drug for use in photodynamic therapy; and (ii) fluorescence quenching by metal ions, potential fluorescent probe. The immobilization of porphyrins in silica spheres of size < 100 nm was achieved by the sol-gel or microemulsion approach. The sol-gel method required the modification of porphyrin molecules with an organosilane reagent and resulted in spheres of about 70 nm. The microemulsion method did not require the modification of porphyrin molecules and resulted in spheres of about 30 nm, very stable in aqueous solution. The immobilized porphyrins preserved their optical properties and the capacity to generate singlet oxygen. Singlet oxygen was detected by a direct method from its characteristic phosphorescence decay curve at near-infrared and by a chemical method using 1,3-diphenylisobenzofuran to trap singlet oxygen. The lifetime of singlet oxygen, when a suspension of porphyrin-loaded silica spheres in acetonitrile was excited at 532 nm, was determined as 52 &#181;s, which is in good agreement with the value determined for a standard methylene blue solution under the same conditions. The porphyrin-loaded silica spheres have an efficiency of singlet oxygen generation similar or even higher than the quantum yield of free porphyrins. This high efficiency of singlet oxygen generation was attributed to changes on the monomer-dimer equilibrium after photosentisizer immobilization in the silica matrix. The use of the immobilized porphyrins as fluorescent probes for iron sensing was also investigated. The interaction of free and silica immobilized hematoporphyrin IX with iron resulted in sites of strong and weak interaction according to the concentration range. The fluorescence quenching of Hp IX, free and immobilized in silica spheres follows a linear correlation with the iron concentration from 0 to 60&#181;M. In conclusion, the immobilization of porphyrins in silica nanoespheres allowed the dispersion of insoluble porphyrins in water, while preserving the accessibility to molecular oxygen and metal ions and broadening the scope of applications.
89

Interação de porfirinas hidrofílicas e de hemoglobina extracelular com modelos biomiméticos de membrana biológica / Interaction of hidrophilic porphyrins and extracellular hemoglobin with biomimetic models of biological membranes

Patricia Soares Santiago 04 April 2008 (has links)
Na primeira parte deste trabalho foi estudada a interação da porfirina catiônica meso-tetrakis N-metil-4-piridil (TMPyP) e a porfirina aniônica meso-tetrakis 4-fenilsulfonato (TPPS4) nas formas de base livre com sistemas modelos de membrana biológica (micelas iônicas, micelas mistas e vesículas de fosfolipídios) em soluções aquosas, através das técnicas de absorção ótica, espalhamento de luz ressonante (RLS do inglês \"resonante light scattering), fluorescência e SAXS, do inglês \"Small Angle X-Ray Scattering\". As curvas de SAXS das micelas catiônicas de CTAC (cloreto de cetiltrimetilamônio) foram ajustadas como um elipsóide prolato na ausência e na presença de 2-10 mM de TPPS4. Os dados de SAXS mostraram que a presença da porfirina TPPS4 modifica o centro hidrofóbico micelar, levando a formação de micelas menores. Através das análises dos dados de SAXS das micelas de SDS (dodecilsulfato de sódio) observamos que a forma da micela na ausência e na presença de 2-10 mM TMPyP apresenta a forma de um elipsóide prolato sem mudanças. Entretanto, o coeficiente de ionização, diminuiu com o aumento da concentração de porfirina, sugerindo a \"blindagem\" da carga aniônica do SDS pela porfirina catiônica. A supressão de fluorescência da TPPS4 e TMPyP foi estudada na ausência e na presença de diferentes micelas de surfactantes, tais como as de SDS, CTAC, HPS (N-hexadecil-N,N,dimetil-3-amônio-1-propano sulfato) e TX-100 (t-octil-fenoxi-polietoxi-etanol). O iodeto de potássio (KI) foi utilizado como supressor. Os gráficos de Stern-Volmer dos dados de fluorescência no estado estacionário foram ajustados pela equação quadrática, incluindo a supressão dinâmica (KD) e estática (KS). Os valores de KS são muito menores do que os valores de KD. Os resultados da TMPyP são consistentes com as constantes de ligação reportadas na literatura: uma redução significativa de supressão acontece para a TMPyP na presença de SDS, e uma redução moderada é observada para o sistema TMPyP-HPS e quase nenhuma mudança é vista para a TMPyP na presença de TX-100. Para o sistema CTAC-TPPS4 um aumento na supressão foi observado quando comparada com a TPPS4 em tampão puro. Isto provavelmente é associado ao acúmulo de iodeto na interface da micela catiônica. A atração entre a cabeça polar do CTAC e I-, e a repulsão entre SDS e I-, aumenta e reduz a supressão de fluorescência, respectivamente, das porfirinas que se localizam na interface micelar. A pequena supressão da TPPS4 em TX-100 é coerente com a forte ligação entre a TPPS4-TX-100 reportada na literatura. A TPPS4 e a TMPyP na presença de concentrações baixas dos surfactantes CTAC e SDS, respectivamente, apresentaram formação de agregados pré-micelares. A adição de surfactante neutro, TX-100, reduziu o efeito de agregação, acompanhada pelas várias técnicas espectroscópicas utilizadas neste trabalho. Portanto, sob condições onde temos a máxima formação de agregados (porfirina-surfactante), a titulação da TPPS4 com micelas de 40%CTAC-60%TX-100 e a TMPyP com micelas de 80%SDS-20%TX-100 não foi suficiente para eliminar a agregação, apesar da diminuição significativa do efeito de supressão de fluorescência e da intensidade de luz espalhada. A interação da TMPyP com 1-Palmitoil-2-Oleoil-sn-Glicero-3-fosfocolina (POPC), 1-Palmitoil-2-Oleoil-sn-Glicero-3-[Fosfo-rac-(1-glicero)] (POPG) e a mistura POPC + POPG é predominantemente devido à contribuição de eletrostática. O aumento da carga negativa, devido à adição de POPG, favorece a interação das vesículas com a porfirina catiônica. Na segunda parte deste trabalho foram estudados os efeitos de três surfactantes na estrutura oligomérica da hemoglobina extracelular gigante de Glossoscolex paulistus (HbGp) na sua forma oxi. O estudo com o SDS, CTAC e HPS permitiu diferenciar os efeitos de cargas opostas da cabeça polar dos surfactantes na dissociação da estrutura oligomérica e na autoxidação da hemoglobina. A interação do HPS com HbGp foi claramente menos intensa que a interação desta hemoglobina com os surfactantes catiônico (CTAC) e aniônico (SDS). Provavelmente, esta menor interação da HbGp com HPS, quando comparada com o SDS e o CTAC, é devido a menor atração eletrostática entre o HPS e os sítios iônicos da proteina. Dados espectroscópicos foram discutidos e comparados com os da literatura, afim de compreender a interação hemoglobina-surfactante, e como o ponto isoelétrico ácido (pI) pode influenciar na relação da estrutura-atividade das hemoglobinas gigantes extracelulares. As amostras de HbGp foram estudadas por espalhamento de luz dinâmico (DLS do inglês \"Dynamic light scattering\"). Na faixa de pH 6.0 a 8.0, HbGp é bastante estável e a distribuição de tamanho das partículas é monodispersa com um diâmetro hidrodinâmico médio (Dh) de 27 nm. O aumento dos valores de pH (pH>9.0) induziu um processo de dissociação irreversível, resultando num valor do Dh menor (10 nm). A diminuição do Dh sugere uma dissociação completa da hemoglobina. Em pH>9,0 a cinética de dissociação é lenta, com um mínimo 24 h para ser completada. As constantes cinéticas de dissociação aumentam progressivamente, com o aumento do valor do pH. As curvas de melting point para HbGp apresentaram dissociação oligomérica e desnaturação da proteina em função do pH. Os processos de autoxidação e dissociação estão intimamente relacionados, de modo que a dissociação da proteina oligomérica promove um aumento na velocidade de autoxidação e vice-versa. / In the first part of this work interactions of the cationic meso tetrakis (4-N-methilpyridil) porphyrin (TMPyP) and meso-tetrakis (4-sulfonatophenyl) porphyrin (TPPS4) in the free base forms with membrane model systems (ionic micelles, mixed micelles and phospholipids vesicles) in aqueous solutions, have been investigated by optical absorption, resonance light scattering (RLS), fluorescence and SAXS (Small Angle X-Ray Scattering). The best-fit SAXS curves were obtained assuming for cetyltrimethylammonium chloride (CTAC) micelle a prolate ellipsoidal shape in the absence and upon incorporation of 2-10 mM TPPS4. SAXS results show that the presence of TPPS4 impacts on micellar hydrophobic core, leading to a micellar reassembling into smaller micelles. SAXS data analysis demonstrated a prolate ellipsoidal shape for sodium dodecyl sulfate (SDS) micelles; no significant changes in shape and size were observed for SDS-TMPyP co-micelles. Moreover, the ionization coefficient, &alpha;, decreases with the increase of the porphyrin concentration, suggesting the \"screening\" of the anionic charge of SDS by the cationic porphyrin. These results are consistent with optical absorption, fluorescence and RLS spectroscopies data, allowing to conclude that neutral surfactants present a smaller interaction with the cationic porphyrin as compared with ionic surfactants. Fluorescence quenching of TPPS4 and TMPyP is studied in aqueous solution and upon addition of micelles of SDS, CTAC, N-hexadecyl-N,N-dimethyl-3-ammonio-1- propanesulfonate (HPS) and t-octylphenoxypolyethoxyethanol (Triton X-100). Potassium iodide (KI) was used as quencher. Steady-state Stern-Volmer plots were best fitted by a quadratic equation, including dynamic (KD) and static (KS) quenching. KS was significantly smaller than KD. For TMPyP quenching results are consistent with reported binding constants: a significant reduction of quenching takes place for SDS, a moderate reduction is observed for HPS and almost no change is seen for Triton X-100. For CTAC-TPPS4 system an enhancement of quenching was observed as compared to pure buffer. This is probably associated to accumulation of iodide at the cationic micellar interface. The attraction between CTAC headgroups and I-, and repulsion between SDS and I-, enhances and reduces the fluorescence quenching, respectively, of porphyrins located at the micellar interface. The small quenching of TPPS4 in Triton X-100 is consistent with strong binding as reported in the literature. Anionic TPPS4 and cationic TMPyP in the presence of low concentrations of the surfactants CTAC and SDS, respectively, showed formation of aggregates, monitored by optical absorption, fluorescence and resonance light scattering intensity (RLS). The addition of nonionic surfactant, Triton X-100, reduced the effect of aggregation monitored by the various techniques used in the present work. Therefore, under conditions for the maximum of aggregate formation (porphyrin-surfactant), apparently, the CTAC: TX-100 ratio equal to 40:60 and SDS:TX-100 ratio equal to 80:20 are not sufficient to eliminate aggregation, despite the significant decrease of the quenching effect of fluorescence and of the light scattering intensity. The interaction of TMPyP with 1-Palmitoyl-2-Oleoyl-sn- Glycero-3-Phosphocholine (POPC), 1-Palmitoyl-2-Oleoyl-sn-Glycero-3-[Phospho-rac-(1- glycerol)] (POPG) and the mixture POPC+POPG is predominantly due to the electrostatic contribution. The increase of the negative charge, due to addition of POPG, favors the interaction of vesicles with the cationic porphyrin. On the second part of this work the effects of three surfactants upon the oligomeric structure of the giant extracellular hemoglobin of Glossoscolex paulistus (HbGp) in the oxy - form was studied. The use of SDS, CTAC and HPS has allowed to differentiate the effects of opposite headgroup charges on the oligomeric structure dissociation and hemoglobin autoxidation. Furthermore, the interaction of HPS with HbGp was clearly less intense than the interaction of this hemoglobin with cationic (CTAC) and anionic (SDS) surfactants. Probably, this lower interaction with HPS is due to the lower electrostatic attraction between the HPS surfactant and the protein surface ionic sites when compared to the electrostatic interaction between HbGp and cationic and anionic surfactants. Spectroscopic data are discussed and compared with the literature in order to improve the understanding of hemoglobin-surfactant interaction as well as the acid isoelectric point (pI) influence of the giant extracellular hemoglobins on its structure-activity relationship. HbGp samples were studied by dynamic light scattering (DLS). In the pH from range 6.0 to 8.0, HbGp is stable and a monodisperse size distribution with a z-average hydrodynamic diameter (Dh) of 27±1 nm is observed. More alkaline pH (pH>9.0) induced an irreversible dissociation process, resulting in smaller Dh of 10±1 nm. Dh decrease suggests a complete hemoglobin dissociation. At pH 9.0 the dissociation kinetics is slow, taking a minimum of 24 h to be completed. Dissociation rate constants progressively increase at higher pH. Melting curves for HbGp showed oligomeric dissociation and protein denaturation as a function of pH. Autoxidation and dissociation processes are intimately related, so that oligomeric protein dissociation promotes the increase of autoxidation rate and vice-versa.
90

"Avaliação do uso de corantes fluorescentes associados ao DIAGNOdent para detecção de perda mineral decorrente da cárie dentária" / Evaluation of the use of fluorescent dyes associated with diagnodent in detecting mineral loss from dental caries

Fausto Medeiros Mendes 11 July 2005 (has links)
Apesar de extensivamente estudado para utilização em superfícies oclusais, o DIAGNOdent tem demonstrado um desempenho insatisfatório para medição de pequenas alterações minerais. Isso se deve ao fato do aparelho provavelmente medir o aumento de fluorescência decorrente de alterações orgânicas decorrentes do processo carioso, ao invés das alterações minerais. Portanto, o objetivo do presente estudo in vitro foi propor a associação do DIAGNOdent com dois corantes fluorescentes e avaliar o desempenho do método na detecção de lesões de cárie em superfícies lisas e oclusais, avaliar a capacidade de detecção precoce da desmineralização e testar a capacidade dos métodos em quantificar a perda mineral de lesões de superfície lisa. Para todos os experimentos, dentes decíduos foram utilizados. Os corantes selecionados foram uma solução de tetrakis (N-metilpiridil) porfirina (TMPyP) a 0,2 mM e uma solução de protoporfirina IX (PPIX) a 4 mM, dissolvida em dimetil sulfóxido e água (1:1). Lesões artificiais de cárie formadas até 16 dias e lesões artificiais de cárie formadas durante 12, 24, 48 e 96 h foram avaliadas com o DIAGNOdent sem e com os corantes para avaliar se havia correlação com perda mineral e melhora no desempenho na detecção dessas lesões. Estudos com os métodos em lesões naturais de cárie em superfície oclusal também foram realizados. A avaliação da perda mineral das lesões artificiais formadas até 16 dias foi determinada pela perda de cálcio pelas amostras, mensurada por espectrometria de emissão atômica, e pela profundidade das lesões, 11 avaliada em microscópio de luz polarizada. Nas lesões precoces, a perda mineral foi avaliada através da perda de cálcio, enquanto que a validação realizada nas lesões oclusais foi feita através de exame histológico. Correlação entre as leituras do aparelho com e sem os corantes e as avaliações realizadas na validação das lesões, bem como parâmetros para indicar o desempenho dos métodos na detecção dessas lesões foram calculados. A detecção das lesões artificiais de cárie foi feita de modo mais eficiente utilizando o DIAGNOdent com os corantes (principalmente com a TMPyP), comparado ao método do DIAGNOdent isolado. Já a quantificação das lesões foi mais adequada com o DIAGNOdent utilizado com PPIX. Para as lesões iniciais, a associação entre a TMPyP e o DIAGNOdent proporcionou uma detecção bastante precoce e uma boa quantificação da desmineralização, comparado aos outros métodos. Já para as lesões oclusais, não foram encontradas diferenças significantes entre os métodos. Em conclusão, a utilização do DIAGNOdent associado à TMPyP proporciona uma melhor performance na detecção de lesões artificiais de cárie de superfície lisa e na detecção precoce da desmineralização causada pela cárie dentária, enquanto que a associação do método com a PPIX obtém uma melhor quantificação das lesões artificiais de cárie em superfície lisa de dentes decíduos formadas em períodos maiores. / Despite the DIAGNOdent has been extensively studied in occlusal surfaces, the device has presented unsuitable performance in the evaluation of the minor mineral changes. This is owing to the fact that the device probably measures fluorescence increase in caries lesions due to changes in the organic content of the lesions rather than mineral loss. Thus, the aim of the present in vitro study was to propose the association of the DIAGNOdent with two fluorescent dyes and to evaluate the performance of the methods in detecting smooth and occlusal surfaces caries lesions, to evaluate the capability of the detection of early demineralization, and to test the feasibility of the methods for quantification of mineral loss from smooth surface caries lesions. Primary teeth were used in all experiments. The selected dyes were a solution contained 0,2 mM tetrakis(N-methylpyridyl)porphyrin (TMPyP) and a solution with 4 mM protoporphyrin IX (PPIX) in water and dimethyl sulfoxide (1:1). Artificial caries lesions created for until 16 days and for 12, 24, 48 e 96 h were measured with the DIAGNOdent without or with the dyes to evaluate the correlation with mineral loss and the performance of the detection of these caries lesions. Experiments with the methods were also carried out to detect natural occlusal caries lesions. Mineral loss measurements of the artificial caries lesions were evaluated in terms of the calcium loss values, determined by atomic emission spectrometry, and lesions depth values, evaluated by polarized light microscope. In the early caries lesions, calcium loss was determined, and the validation of the occlusal caries lesions was performed by histopathological examination. Correlation between 13 DIAGNOdent readings associated or no with the dyes and the determinations performed to validate the caries lesions, as well as the parameters related to the performance of the methods to detect these lesions were calculated. The detection of the artificial caries lesions were better performed with the DIAGNOdent associated with the dyes (especially with TMPyP), compared to the method using the DIAGNOdent without dyes. With regard to the quantification of the caries lesions, the method with PPIX presented better results. Regarding the early caries lesions, the association between DIAGNOdent and TMPyP provided a very early detection and a suitable quantification of the demineralization, compared with the other methods. Concerning the occlusal caries lesions, there were no significant differences among the methods. In conclusion, the use of the DIAGNOdent associated with TMPyP provides better performance in detecting smooth surface artificial caries lesions and to detect early demineralization from dental caries, while the association of the device with PPIX improves the quantification of the smooth surface artificial caries lesions produced for longer periods, in primary teeth.

Page generated in 0.0712 seconds