• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 250
  • 127
  • 58
  • 25
  • 6
  • 5
  • 4
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 519
  • 258
  • 154
  • 129
  • 115
  • 96
  • 94
  • 94
  • 94
  • 94
  • 81
  • 64
  • 58
  • 49
  • 45
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Portable LED fluorescence instrumentation for the rapid assessment of potable water quality

Bridgeman, John, Baker, A., Brown, D., Boxall, J.B. 22 April 2015 (has links)
Yes / Characterising the organic and microbial matrix of water are key issues in ensuring a safe potable water supply. Current techniques only confirm water quality retrospectively via laboratory analysis of discrete samples. Whilst such analysis is required for regulatory purposes, it would be highly beneficial to monitor water quality in-situ in real time, enabling rapid water quality assessment and facilitating proactive management of water supply systems. A novel LED-based instrument, detecting fluorescence peaks C and T (surrogates for organic and microbial matter, respectively), was constructed and performance assessed. Results from over 200 samples taken from source waters through to customer tap from three UK water companies are presented. Excellent correlation was observed between the new device and a research grade spectrophotometer (r2 = 0.98 and 0.77 for peak C and peak T respectively), demonstrating the potential of providing a low cost, portable alternative fluorimeter. The peak C/TOC correlation was very good (r 2 = 0.75) at low TOC levels found in drinking water. However, correlations between peak T and regulatory measures of microbial matter (2 day/3 day heterotrophic plate counts (HPC), E. coli, and total coliforms) were poor, due to the specific nature of these regulatory measures and the general measure of peak T. A more promising correlation was obtained between peak T and total bacteria using flow cytometry. Assessment of the fluorescence of four individual bacteria isolated from drinking water was also considered and excellent correlations found with peak T (Sphingobium sp. (r 2 = 0.83); Methylobacterium sp. (r 2 = 1.0); Rhodococcus sp. (r 2 = 0.86); Xenophilus sp. (r 2 = 0.96)). It is notable that each of the bacteria studied exhibited different levels of fluorescence as a function of their number. The scope for LED based instrumentation for insitu, real time assessment of the organic and microbial matrix of potable water is clearly demonstrated. / The research reported here was sponsored by the Engineering and Physical Sciences Research Council under grants EP/I001379/1, EP/I001468/1 and EP/I029346/1.
122

Élaboration d'une méthode d'analyse de la capacité de réparation de l'ADN : application à une population exposée à l'arsenic via la consommation d'eau souterraine

Zinflou, Corinne 18 April 2018 (has links)
L'exposition via l'eau potable à des concentrations élevées d'arsenic (>10 ug/L), est mondialement répandue et s'associe à de sévères pathologies dont certains cancers. Un mécanisme sous-jacent implique l'altération de la capacité de réparation de l'ADN (CRA), un important modulateur de la susceptibilité au cancer. Notre but était d'élaborer une méthode d'évaluation de la CRA et d'estimer son applicabilité à l'étude de la CRA de 102 résidents de Chaudière-Appalaches (Québec, Canada) chroniquement exposés à différentes concentrations d'arsenic dans l'eau (0.01-140 ug/L). Deux tests in vitro ont été développés, pour évaluer la réparation par excision/resynthèse d'ADN, de lymphocytes congelés et non-stimulés. Les mesures dans notre échantillon indiquent 42% des individus montrant une activité de réparation in vitro ralentie; l'absorption d'As3+ était négativement corrélée avec la proportion d'individus à l'activité ralentie (p = 0.0155). Nos résultats suggèrent que ces tests permettraient d'évaluer la CRA dans le cadre d'études épidémiologiques de carcinogénèse environnementale.
123

The effects of impure water sources on the early-age properties of calcium sulfoaluminate cements

Long, Wendy 13 December 2019 (has links)
One of the benefits of calcium sulfoaluminate (CSA) cements is that these materials gain strength rapidly, where strength development is often measured in hours instead of days. This property makes these materials desirable for use in temporary, non-reinforced repairs of roadways, airfields, and navigable locks. The rapid repair of these infrastructure elements is critical to transporting supplies into regions devastated by disaster. In these austere environments, potable water may not be available in sufficient quantities to make vital repairs, and the use of impure water in the production of CSA cement-based concrete would be advantageous. However, the hydration products formed by CSA cement are substantially different from those formed by portland cement and may react differently to impurities that water sources may contain. This Thesis investigates the impact of various salts and impure water sources on the early-age strength development of commercially-available CSA cement-based concrete.
124

Quantification d'un contaminant et d'un traceur d'intérêt émergent dans l'eau potable

Grondin, Antoine 02 February 2021 (has links)
La production et la distribution de l’eau potable sont assujetties à un encadrement légal afin d’assurer une eau potable de qualité et propre à la consommation humaine. Cependant, l’eau peut être vulnérable à la présence de contaminants provenant de la source d’eau, de l’usine de production d’eau potable (UPEP) ou du réseau de distribution. Ce mémoire vise l’étude de deux contaminants d’intérêt émergent pouvant se retrouver dans l’une ou l’autre des composantes du système d’approvisionnement en eau. L’acésulfame de potassium (ACE) est un composé provenant des sources d’eau alors que le chlorure de vinyle (CV) est un contaminant qui provient généralement du réseau de distribution. Présentement, très peu de recherches au Québec et au Canada ont porté sur la présence de ces deux composés dans l’eau potable. Dans ce mémoire, un chapitre se concentre sur la présence du CV dans l’eau potable de certains réseaux de distribution du Québec. Ce contaminant se retrouve dans l’eau potable en raison de son relargage par les conduites de polychlorure de vinyle (PCV) utilisées dans des réseaux de distribution d’eau potable. Les résultats issus de cette étude ont permis de dresser un portrait de la présence du contaminant dans les réseaux étudiés. Les concentrations de CV ont varié entre la limite de quantification méthodologique (LQM), qui est de 0,04 µg/L, et 0,35 µg/L. Le résultat maximal atteint représente une concentration de près de six fois inférieures à la norme exigée par le règlement sur la qualité de l’eau potable du Québec (RQEP). Un autre chapitre du mémoire rapporte l’étude de l’ACE, un contaminant d’intérêt émergent. Cet édulcorant, non biodégradable, se retrouve dans les sources d’eau potable suite à la consommation et à l’excrétion de ce produit par l’humain. Il est acheminé dans l’environnement via les rejets d’eaux usées traitées ou non traitées dans les milieux récepteurs. Ce contaminant a été quantifié à l’eau brute de cinq UPEP à des concentrations moyennes variant de 0,08 ± 0,04 µg/L à 0,14 ± 0,02 µg/L. De plus, l’efficacité des usines à retirer le contaminant de l’eau a aussi été abordée dans cette étude. Dépendamment des procédés de traitement employés, l’efficacité des UPEP à retirer l’ACE a varié entre 21% et 91%. Selon les résultats, la désinfection à l’ozone et au chlore sont les plus efficaces pour retirer l’ACE de l’eau.
125

Investigating the Impact of Aquifer Long Term Replenishment on the Potomac Aquifer System in Virginia

Martinez, Meredith Grace 04 April 2022 (has links)
Groundwater plays a fundamental role in water resource sustainability in Virginia (USA), but overpumping has caused significant declines in the potentiometric surface in the Potomac Aquifer System (PAS). With water levels falling, communities are at risk of wells running dry, saltwater intrusion, and land subsidence. The Sustainable Water Initiative for Tomorrow (SWIFT) project is an aquifer long-term replenishment (ALTR) project that uses continuous recharge into the multi-layered confined aquifer system to restore the potentiometric surface over space and time and increase storage in the system. The SWIFT Research Center (SWIFT-RC) is a 1 million gallon per day (MGD) demonstration facility in Suffolk, Virginia that recharges the PAS through a multi-screen well. Addressing research questions about the impact of continuous, sustained recharge on aquifer systems is crucial to the long-term sustainability of an ALTR project. Quantifying how flow moves through the multi-layered system is necessary to communicate travel times and water quality impacts on the aquifer system. This work uses injectate as an intrinsic tracer, an in-situ flowmeter, and a bromide tracer test to evaluate how flow is distributed through the eleven screens in the recharge well and to assess how flow distribution changes over time. Typically, flow distribution in multi-screen wells is estimated only once over the length of a project and assumed to remain constant for modeling purposes; by measuring flow distribution using multiple methods over the course of the project, this work shows that flow distribution is not constant. In future ALTR projects, developing a consistent and robust monitoring plan to use injectate as an indicator of movement through the aquifer system, paired with other methods to monitor changes in flow distribution, will be a critical part of effectively evaluating how flow moves through the groundwater system. / Doctor of Philosophy / Groundwater plays a fundamental role in water resource sustainability in Virginia (USA), but overpumping has left the Potomac Aquifer System (PAS) depleted. With water levels falling, communities are at risk of wells running dry, adverse water quality changes, and even changes to the land surface due to subsurface settling. The Sustainable Water Initiative for Tomorrow (SWIFT) project is an aquifer long-term replenishment (ALTR) project that uses continuous recharge into the deep aquifer system to restore water levels and increase storage in the system. The SWIFT Research Center (SWIFT-RC) is a 1 million gallon per day (MGD) demonstration facility in Suffolk, Virginia that recharges the PAS through a multi-screen well. Addressing research questions about the impact of continuous, sustained recharge on aquifer systems is crucial to the long-term sustainability of an ALTR project. Quantifying how flow moves through the multi-layered system is necessary to communicate travel times and water quality impacts on the aquifer system. This work uses multiple methods to evaluate how flow is distributed through the eleven screens in the recharge well and to assess how flow distribution changes over time. Typically, flow distribution in multi-screen wells is estimated only once over the length of a project and is assumed to remain constant for modeling purposes; by measuring flow distribution using multiple methods over the course of the project, this work shows that flow distribution is not constant. In future ALTR projects, developing a consistent and robust monitoring plan to use recharge water itself as an indicator of movement through the aquifer system, paired with other methods to monitor changes in flow distribution, will be a critical part of effectively evaluating how flow moves through the groundwater system.
126

Gestion adaptative des débits des réseaux de distribution pour contrôler la qualité de l’eau potable

Maleki, Mahnoush 17 May 2024 (has links)
Les réseaux de distribution d'eau potable (RDE) revêtent une grande importance dans la gestion des eaux en milieu urbain. Avoir de bonnes informations sur les paramètres qui impactent la qualité de l'eau dans les RDE peut améliorer significativement la gestion des systèmes de distribution d'eau à la fois à court terme, en optimisant les indicateurs de qualité de l'eau, et à long terme, en facilitant la planification stratégique des décideurs. Obtenir des données à l'échelle réelle sur la dégradation du désinfectant secondaire pour différentes caractéristiques de tuyaux est à la fois difficile et impératif pour une gestion efficace de la qualité de l'eau. Les coefficients de réaction cinétique de dégradation du chlore associés au volume d'eau ($k_b$) et à la paroi du tuyau ($k_w$) jouent un rôle essentiel dans la dégradation de la qualité de l'eau. Cependant, la détermination de ces coefficients peut être un processus coûteux et chronophage. Deux indicateurs clés pour évaluer la qualité de l'eau dans un RDE sont CCRL et le temps de séjour de l'eau (TSE). Pour maintenir la CCRL dans des plages acceptables dans l'ensemble du RDE, le placement stratégique et le fonctionnement de stations de rechloration se révèlent avantageux, offrant une option plus flexible et économique par rapport à l'injection de chlore uniquement à l'usine de traitement de l'eau (UTE) ou dans les réservoirs. En revanche, la réduction du TSE peut être réalisée en utilisant des vannes de régulation de débit (*flow control valve*, FCV) pour modifier les parcours hydrauliques, présentant une approche multifacette pour assurer et optimiser la qualité de l'eau dans l'ensemble d'un RDE. Cette recherche aborde ces problèmes en se concentrant sur la détermination des caractéristiques importantes des tuyaux et du système hydraulique qui influencent sur les coefficients de dégradation du chlore. La nouveauté de la recherche se concentre sur la génération de nouvelles données et le développement de méthodes, dans le but de dériver des stratégies pour gérer la qualité de l'eau dans ses nombreux aspects, tels que les CCRL détectables et les temps de rétention de l'eau, à tout moment et n'importe où dans un réseau de distribution d'eau de manière rentable. À travers des analyses statistiques, les caractéristiques des tuyaux et du système hydraulique les plus importantes sont identifiées en les corrélant avec les coefficients de dégradation $k_b$ et $k_w$ estimés dans des conditions à l'échelle réelle dans le RDE principal de la ville de Québec. La recherche identifie également les caractéristiques et les emplacements de tuyaux les plus pertinents pour la détermination spécifique des coefficients de dégradation du chlore dans le RDE. Divers scénarios de valeurs de $k_b$ et $k_w$ sont évalués et comparés avec des données mesurées dans le RDE. Le scénario le plus précis est comparé au scénario le moins coûteux pour identifier les informations les plus efficaces nécessaires, en tenant compte de facteurs tels que l'emplacement dans le RDE et les caractéristiques des tuyaux (période d'installation, diamètre et matériau). Enfin, cette étude vise à développer une approche adaptative à l'échelle réelle unique et innovante pour la gestion rentable des FCV et des stations de rechloration dans le RDE. Cette approche améliore non seulement la qualité de l'eau, mais maintient des plages de pression et de CCRL acceptables, fournissant des informations précieuses pour une gestion efficace du système. La méthodologie proposée est également appliquée au RDE de la ville de Québec, en considérant trois formulations d'optimisation: 1) optimisation du fonctionnement des FCV, 2) optimisation du fonctionnement des stations de rechloration, et 3) une combinaison des deux, appelée gestion adaptative. Les résultats ont montré que la période d'installation influence significativement le $k_w$, notamment pour les tuyaux installés avant 1960. En ce qui concerne les matériaux, les tuyaux en fonte grise présentent une dégradation plus importante des parois que les tuyaux en fonte ductile et en PVC. Dans le RDE de la ville de Québec, les valeurs les plus élevées du coefficient cinétique obtenues correspondaient étroitement aux données de 2020, soulignant le besoin de coefficients cinétiques précis pour des prédictions plus proches de la réalité. Un modèle adaptatif a optimisé les opérations du RDE, améliorant notablement la qualité de l'eau en réduisant le nombre de nœuds avec un CCRL inférieur à 0,2 mg/l de 88% grâce à l'optimisation des stations de rechloration. Cette recherche complète, composée de trois articles interdépendants, aborde chacun des aspects distincts mais interconnectés. Cette recherche facilite la gestion adaptative des réseaux de distribution municipaux dans le monde entier, améliorant la prise de décision concernant la rechloration dans les RDE. Elle vise à minimiser les risques sanitaires et les coûts associés à la désinfection secondaire tout en tenant compte des chemins hydrauliques et de la qualité de l'eau. / Water distribution systems (WDS) have a great importance in the management of urban waters. Having good information about the parameters that impact water quality in WDS can significantly enhance the management of water distribution systems in both the short-term, through optimizing water quality indicators, and the long-term, by facilitating strategic planning by decision makers. Obtaining full-scale data on the degradation of residual disinfectant for various pipe characteristics is both challenging and imperative for effective water quality management. The chlorine degradation kinetic reaction coefficients associated with the bulk volume of water ($k_b$) and at the pipe walls ($k_w$) during water distribution play an essential role in water quality degradation. However, determining these coefficients can be costly and time-consuming. Two key indicators in evaluating water quality within a WDS are free residual chlorine concentration (FRCC) and water residence time (WRT). To maintain FRCC within acceptable ranges across the entire WDS, the strategic placement and operation of chlorine booster stations proved advantageous, providing a more flexible and economic option compared to the exclusive injection of chlorine at the water treatment plant (WTP) or in tanks. Conversely, the reduction of WRT can be achieved by using flow control valves (FCV) to modify hydraulic paths, presenting a multifaceted approach to ensuring and optimizing water quality throughout a WDS. This research addresses these issues by focusing on determining important pipe and hydraulic system characteristics that influence chlorine degradation coefficients. The research novelty focuses on the generation of new data and the development of methods, aiming to derive strategies to manage water quality in its many aspects, such as detectable FRCC and WRT, at any time and anywhere in a WDS cost-effectively. Through statistical analyses, the pipe and hydraulic system characteristics are identified by correlating them with $k_b$ and $k_w$ degradation coefficients estimated in full-scale conditions within Quebec City's primary WDS. The research also pinpoints the most relevant pipe characteristics and locations for the accurate determination of chlorine decay coefficients in the WDS. Various scenarios of $k_b$ and $k_w$ values are evaluated and compared with measured data in the WDS. The most accurate scenario is compared with the lowest-cost scenario to identify the most effective information needed, considering factors such as location within the WDS and pipe characteristics (period of installation, diameter, and material). Finally, this thesis develops a unique and innovative adaptive full-scale approach for cost-effective management of FCV and chlorine booster stations in WDS. This approach not only enhances water quality, but also maintains acceptable pressure and FRCC ranges, providing valuable insights for effective system management. The proposed methodology is also applied to Quebec City's main WDS, considering three optimization formulations: 1) FCV operation optimization, 2) chlorine booster station operation optimization, and 3) a combination of the two, termed adaptive management. The results showed that the installation period significantly influences $k_w$ specially for the pipes installed before 1960. Regarding the materials, grey cast iron pipes showing higher degradation at walls than ductile cast iron and PVC pipes. In Quebec City's WDS, the highest values of obtained kinetic coefficient closely matched the 2020 data, highlighting the need for accurate kinetic coefficients for precise predictions. An adaptive model optimized the WDS operations, notably improving water quality by reducing nodes with FRCC less than 0.2 mg/l by 88% through optimizing chlorine booster stations. This research thesis, comprising three interrelated papers, each paper addresses distinct but interconnected aspects. This research facilitates adaptive management for municipal distribution networks worldwide, improving decision-making on WDS rechlorination. It aims to minimize health risks and costs associated with secondary disinfection while considering hydraulic paths and water quality.
127

Subsidio de agua potable en Chile : análisis distributivo años 1998, 2000 y 2003

Contreras Hormazábal, Francisco, Ramos Muñoz, Alejandro 01 1900 (has links)
Seminario de título Ingeniero Comercial, Mención Economía / El objetivo de esta tesis es analizar el comportamiento distributivo que ha desarrollado el subsidio de agua potable (SAP) en Chile para los años 1998, 2000 y 2003. Principalmente se busca analizar el impacto de la modificación del criterio operacional de asignación del subsidio de agua potable aplicada en el año 2002. Para el caso analítico se utilizan los datos contenidos en la encuesta socioeconómica CASEN para los años definidos anteriormente. Estos datos son contrastados con los datos contenidos en los informes de MIDEPLAN, entidad estatal que desarrolla el proceso de asignación entre los hogares del país. Utilizando los datos contenidos en CASEN se pueden construir curvas relativas y absolutas de concentración que permiten observar la distribución del subsidio de agua potable entre los deciles de ingreso y permite comparar entre diferentes años la evolución de la cobertura sobre los deciles de menores ingresos dentro del país. Para una medida más exacta de comparación entre las curvas, se calcularon los coeficientes Gini de distribución del subsidio. Se pudo comprobar la progresividad del SAP para los tres años estudiados mediante la comparación de las curvas relativas de concentración y los coeficientes Gini, ubicándose como el año de mejor distribución del subsidio la curva definida para el año 1998 y presentándose un empeoramiento de un 22% en el coeficiente para el año 2003. Con respecto a la cobertura nacional del subsidio representada en la curva absoluta de concentración, se pudo observar que el año de mayor cobertura es el año 2003, seguido por el año 2000 y el año 1998, con un 18%, un 15% y un 13%, respectivamente. Como principal conclusión el año 2003 es el año de mayor cobertura nacional del subsidio pero de menor progresividad en la asignación del subsidio. Por otra parte, el año 1998 es el año de mayor progresividad en la asignación pero de menor cobertura del subsidio. El año 2000 se ubica como un año de transición entre los años 1998 y 2003.
128

Estudio técnico sanitario de la producción de agua potable en el Perú

Calderon Huayhualla, Milagros Amanda, Campos Conde, Yitzhak Julianne, Quispe Piñas, Brooke Cristel, Lazo Pérez, Diego Paul, Socualaya Molina, Bruno Gonzalo 23 February 2021 (has links)
La situación actual de acceso al agua en nuestro país y en la región, motiva a contribuir en la investigación de alternativas de captación de agua y tratamiento de la misma para uso de la población, en especial del grupo humano que no tiene acceso al recurso que, según organismos mundiales, es un derecho de la humanidad. La presente investigación realiza una revisión bibliográfica general cuyo objetivo es conocer la situación actual del Perú en este tema y de algunos países de la región, de los cuales se conoce que tienen características cercanas a la del Perú. Además, se realiza una revisión bibliográfica de tres métodos de captación, escogidos debido a la gran difusión de los mismos en diferentes países. Estos son la captación de agua de niebla (Atrapanieblas), captación de agua de lluvia y captación de agua de mar. Con los conocimientos adquiridos en la revisión bibliográfica se escogió el agua de lluvia como método a ser detallado debido a considerar a este como uno de los métodos más idóneos para abastecer de agua diferentes zonas del Perú. En la etapa de desarrollo del proyecto se detallan las partes del sistema que componen la captación y tratamiento de agua de lluvia, y se presentan un conjunto de tablas, fórmulas y algunos conceptos que auxilian en la etapa de diseño de las partes del sistema. También se desarrollan los procesos de tratamiento de agua, donde se detallan métodos de filtración de agua para consumo humano y agua no potable, la inserción de los mismos en el sistema y los posibles usos del agua tratada.
129

Impact potentiel de l’utilisation de l’eau de pluie dans le bâtiment sur les consommations d’eau potable à l’échelle urbaine : le cas de l’agglomération parisienne / Potential impact of the use of rainwater within buildings on the consumption of drinking water at a city scale : case of Paris conurbation

Belmeziti, Ali 06 July 2012 (has links)
Ce travail de recherche vise à appréhender les effets engendrés à terme sur la gestion urbaine de l'eau par le développement progressif de la pratique de récupération et d'utilisation de l'eau de pluie (RUEP), et plus particulièrement sur l'alimentation en eau potable. Il est réalisé de manière prospective à l'échelle de l'agglomération parisienne. Plus largement, cette recherche constitue une contribution au débat ouvert depuis quelques années relatif à la remise en question progressive du modèle centralisé de gestion de l'eau en milieu urbain. Après une description de la pratique urbaine de REUP, ce travail établit un état de l'art des outils et des méthodes scientifiques s'y rapportant, et suggère de se focaliser sur le développement d'une approche de changement d'échelles. L'objectif est de produire, à une échelle urbaine, une estimation significative des économies d'eau potable réalisables en substituant à celle-ci de l'eau de pluie récupérée pour des usages ne requérant pas une qualité d'eau alimentaire. Pour ce faire, nous proposons une approche basée sur l'évaluation séquentielle à l'aide d'une échelle intermédiaire (la commune), d'une logique de regroupement de bâtiments aux caractéristiques comparables au regard de la RUEP et de quatre principes (distinction, agrégation, majoration, hiérarchisation).Sur l'agglomération de Paris, la méthodologie mise en œuvre montre que l'eau de pluie récupérée est susceptible de représenter un potentiel équivalent à 65% des besoins en eau non potable et à 11% du volume d'eau potable distribué. Le travail met également en évidence que le secteur résidentiel constitue le gisement principal de ce potentiel, car il détient 2/3 du potentiel global de l'agglomération. Une première analyse du système d'acteurs impliqués dans la RUEP en milieu urbain complète ce travail. Cette analyse permet de dégager un sous ensemble particulier d'acteurs qui ont la capacité d'effectuer une action « levier » sur la diffusion de cette pratique sur une échelle urbaine, soit directement en raison de leur capacité d'action collective (un ensemble de bâtiments par exemple), soit indirectement au travers de leur capacité d'influencer sur les propriétaires des bâtiments (mécanismes d'incitation notamment).Au final, ce travail permet de situer la RUEP en milieu urbain au sein du débat général portant sur les mutations que connaît la ville d'aujourd'hui / This research aims at assessing the effects generated, on management of urban water in the long term, by progressive development of rainwater harvesting (RWH), and more particularly on the drinking water supply. It is carried out in a prospective way on the scale of Paris and its suburbs. On the whole, this research contributes to a controversy about the validity of a centralized model of management of water in an urban environment. After a description of the RWH in urban areas, this report presents state of the art tools and scientific methods, and focuses on the development of a scaling approach. The objective is to produce, a significant assessment of potential potable water savings (PPWS), on an urban scale by substituting part of it by rainwater recovered for uses which do not require such quality. With this aim, we propose an approach based on sequential evaluation using an intermediate scale (the municipality), on merging of buildings with similar characteristics related to RWH and four methodological principles (modeling, aggregation, increase, Ranking strategy)Applied to the Paris agglomeration, the implemented methodology shows that the recovered rainwater volume is likely to represent a potential equivalent of 65% of the demands for non-drinking water and of 11% of the drinking water distributed. This research also highlights that the residential sector constitutes the major contribution of this potential, because it holds 2/3 of the total potential to the Paris agglomeration. The first analysis of the system of actors implied in the RWH in urban environment has also been developed. This analysis makes it possible to identify a specific subset of actors who have the capacity to carry out an “lever” action in generalizing this practice on an urban scale, either directly because of their capacity of leading a collective action (for a set of buildings for example), or indirectly through their capacity to act on the owners of the buildings (by incentive mechanisms in particular).Finally, this work positions RWH in on urban environment within the general debate related to the evolution of present cities
130

Diseño del sistema de abastecimiento de agua potable en la Rinconada de Pamplona Alta, aplicando EPANET y algoritmos genéticos para la localización de válvulas reductoras de presión

Carhuapoma Mendoza, Jenny Claudia, Chahuayo Durán, Adolfo Rogers 11 July 2019 (has links)
En la actualidad, la cobertura de agua potable en el país aún es insuficiente, sobre todo en las zonas rurales del país; de manera similar este problema se presenta en las zonas periurbanas de Lima. Tal como en La Rinconada de Pamplona Alta que se encuentra ubicada en el distrito San Juan de Miraflores, el cual no cuenta con servicio básico de agua potable, el abastecimiento de este recurso se realiza mediante camiones cisterna y son almacenados en tanques, bidones, baldes, etc. Es por ello, que la presente investigación plantea una propuesta de diseño del sistema de abastecimiento de agua potable para la zona de estudio, para lo cual se toma en consideración que el caudal requerido será brindado por SEDAPAL. Debido a que la topografía de la zona de estudio presenta pendientes pronunciadas es necesario utilizar válvulas reductoras de presión, cuya localización se realiza a través de la aplicación del Algoritmo Genético Multiobjetivo, el cual en su codificación incluye el uso del Epanet Programmer’s Toolkit, que viene a ser una biblioteca dinámica (DLL) de funciones que permite a los programadores personalizar el motor de cálculo de EPANET para sus necesidades específicas. En ese sentido, el método utilizado plantea una propuesta de mejora en el proceso de diseño del sistema de abastecimiento de agua potable en La Rinconada de Pamplona Alta del distrito de San Juan de Miraflores. Para lo cual, se utilizó el programa EPANET en la simulación y cálculo hidráulico de la red de distribución por ser un programa de comprobada eficacia y de uso libre. Por otro lado, el resultado del análisis hidráulico de los proyectos de agua potable que se realizan en el país tanto por métodos manuales iterativos o con ayuda de programas de simulación, muchas veces no cumplen con las exigencias del rango de presiones admisibles establecido por el Reglamento Nacional de Edificaciones, lo cual se traduce por un lado en costos de cumplir programas de mantenimiento que suplan estas deficiencias y por otro lado posibles roturas de tuberías o fugas de agua debido a altas presiones. Es por ello que se busca cumplir con los requisitos exigidos por las normas de diseño y a la vez brindar una adecuada presión de servicio, para lo cual se hace uso del Algoritmo Genético Multiobjetivo en el diseño de la red para la zona de estudio, lo cual conllevaría a un ahorro en los costos de operación y mantenimiento. Finalmente el diseño propuesto para el sistema de abastecimiento de agua potable en La Rinconada de Pamplona Alta está conformado por el reservorio RAP-1 que abastece mediante una línea de aducción a cuatro zonas de presión y el reservorio RRP-3 que abastece por otra línea de aducción a tres zonas de presión debido a que la topografía presenta desniveles considerables. Adicionalmente, con el uso de un subprograma incluido en el Algoritmo Genético Multiobjetivo se logró asignar los caudales de demanda de manera automática en todos los nodos de la red de distribución contribuyendo a la mejora en el proceso de diseño mediante el programa EPANET. / At present, the coverage of drinking water in the country is still insufficient, especially in rural areas of the country; similarly, this problem occurs in the peri-urban areas of Lima. Such as the La Rinconada area of Pamplona Alta which is located in the San Juan de Miraflores district that does not have a basic potable water service, the supply of this resource is done by tank trucks and stored in tanks, drums, buckets, etc. It is for this reason that the present investigation proposes a design proposal for the potable water supply system for the study area, for which it is taken into consideration that the required flow will be provided by SEDAPAL. Because the topography of the study area presents steep slopes, it is necessary to use pressure reducing valves, which are localized through the application of the Multiobjective Genetic Algorithm, which in its coding includes the use of the Epanet Programmer's Toolkit, which comes to be a dynamic library (DLL) of functions that allows programmers to customize the EPANET calculation engine for their specific needs. In this sense, the method used proposes a proposal for improvement in the design process of the potable water supply system in La Rinconada de Pamplona Alta in the district of San Juan de Miraflores. For which, the EPANET program was used in the simulation and hydraulic calculation of the distribution network as it is a program of proven effectiveness and free use. On the other hand, the result of the hydraulic analysis of drinking water projects carried out in the country either by iterative manual methods or with the help of simulation programs, often does not meet the requirements of the range of admissible pressures established by the Regulation. National Building, which translates on the one hand in costs of carrying out maintenance programs that supply these deficiencies and on the other hand possible pipe breaks or water leaks due to high pressures. That is why it seeks to meet the requirements of the design standards and at the same time provide adequate service pressure, for which the Multiobjective Genetic Algorithm is used in the design of the network for the study area, which it would lead to savings in operation and maintenance costs. Finally, the proposed design for the drinking water supply system in La Rinconada de Pamplona Alta is made up of the RAP-1 reservoir that supplies four pressure zones through an adduction line and the RRP-3 reservoir that supplies another line of water. adduction to three pressure zones because the topography presents considerable differences in level. Additionally, with the use of a subprogram included in the Multiobjective Genetic Algorithm, it was possible to assign the demand flows automatically in all nodes of the distribution network contributing to the improvement in the design process through the EPANET program. / Tesis

Page generated in 0.08 seconds