• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 12
  • 1
  • Tagged with
  • 38
  • 25
  • 11
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Evaluation préclinique du potentiel thérapeutique de molécules inhibitrices de Mcl-1 au sein de la famille des oligopyridines pour le traitement des cancers de l'ovaire chimiorésistants / Preclinical evaluation of the therapeutic potential of Mcl-1 inhibitory molecules in the oligopyridine family for the treatment of chemoresistant ovarian cancers

Hedir, Siham 15 December 2017 (has links)
Les cancers de l’ovaire demeurant particulièrement meurtriers du fait de leur capacité à développer une résistance aux chimiothérapies conventionnelles, il est donc indispensable de mettre en place de nouvelles stratégies thérapeutiques susceptibles de surmonter la chimiorésistance pour améliorer leur prise en charge. Les travaux antérieurs de l’Unité ont démontré que les protéines anti-apoptotiques Bcl-xL et Mcl-1 coopèrent pour protéger les cellules cancéreuses ovariennes contre l’apoptose et que leur inhibition concomitante conduit à la mort des cellules chimiorésistantes. A ce jour, seuls les inhibiteurs de Bcl-xL/Bcl-2 ont démontré une efficacité en clinique, en particulier l’ABT-263 (Navitoclax). En revanche, l’inhibition de Mcl-1 reste problématique dans un contexte clinique. La recherche d’outils pharmacologiques conduisant à l’inhibition ou à l’inactivation de Mcl-1, utilisables en clinique, reste donc un enjeu majeur, d’autant que cette protéine est désormais désignée comme une cible thérapeutique prioritaire dans de nombreuses localisations tumorales. C’est dans ce contexte que mon projet de thèse s’est inscrit, l’objectif étant d’identifier et d’évaluer de nouveaux inhibiteurs pharmacologiques de Mcl-1 synthétisés par des équipes de chimistes. Dans cette optique, mon projet de thèse s’est scindé en deux parties : Dans une première étude, je me suis attachée à cribler in vitro des molécules appartenant à différentes familles chimiques (Oligopyridines dérivées du Pyridoclax, « Lead » de la première génération des oligopyridines précédemment identifié par notre équipe, ou analogues de MIM1) dans le but d’identifier de nouveaux inhibiteurs de Mcl-1 plus actifs que les molécules dont ils dérivent. Ce travail a permis d’identifier la MR31367, une molécule issue du Pyridoclax qui présente une activité pro-apoptotique plus forte que ce dernier sur plusieurs lignées tumorales ovariennes chimioresistantes. Nous avons également pu mettre en évidence sur ces mêmes modèles que plusieurs molécules issues de MIM1 exhibaient une activité pro-apoptotique amplifiée. Cette étude nous a également permi de mettre en évidence une relation structure activité permettant de classer ces molécules en inhibiteurs spécifiques de Mcl-1 et « dual-inhibiteur » de Mcl-1 et Bcl-xL. Dans une seconde étude, mon travail a consisté en l’évaluation préclinique du sel de Pyridoclax. Nous avons étudié l’effet de différentes doses de Pyridoclax administré par différentes voies d’administration, en agent seul ou en combinaison avec l’ABT-263 sur différents modèles tumoraux établis à partir des lignées chimiorésistantes de cancers ovariens. Nous avons ainsi pu mettre en évidence un effet anti-tumoral du Pyridoclax (20 mg/kg/j) administré par voie IV en agent seul sur des 2 modèles des 3 modèles de xénogreffes, et cela sans toxicité avérée. Ces résultats prometteurs ouvrent des perspectives intéressantes quant à l’utilisation d’inhibiteurs pharmacologiques de Mcl-1 pour le traitement des cancers de l’ovaire / Ovarian cancer is the most leading cause of death from gynecologic malignancies because of its late diagnosis and its ability to develop chemoresistance to conventional therapies. It is now essential to develop new therapeutic strategies to overcome this chemoresistance and improve patient care. Our laboratory has demonstrated the overexpression of the Bcl-2 anti-apoptotic proteins Bcl-xL and Mcl-1 and their cooperation to protect ovarian cancer cells from apoptosis. Currently, the clinically relevant pharmacologic inhibition of Bcl-xL is available using ABT-263 (Navitoclax). However, selective direct Mcl-1 inhibition remained a challenge. This protein is one of the most important anti-apoptotic member which is expressed in multiple cancer types and is at the origin of the acquired resistance to chemotherapy and Bcl-2 family inhibitors (Navitoclax, Venetoclax). Thus, Mcl-1 inhibition represents a major challenge for the clinical success of the Bcl-2 family inhibitors. In this context, I was interested in identifying and evaluating new Mcl-1 inhibitors designed and synthetized by different chemistry research teams. My project was focused on two aspects. In the first part, we have evaluated the cytotoxic effect of different molecules derived from 2 Mcl-1 inhibitors, the Pyridoclax from the oligopyridine family and MIM1. The screening of 8 Noxa-mimetic molecules derived from Pyridoclax allowed us to identify MR31367, one of the most potent oligopyridine molecules that shows a stronger anti-apoptotic activity than Pyridoclax (15μM) and sensitizes different chemoresistant ovarian cancer cell lines (IGROV1-R10, SKOV-3 and A2780) to anti-Bcl-xL strategies (ABT-737, siRNA). Furthermore, we have evaluated the pro-apoptotic activity of 14 MIM1 derivative molecules using the same cellular model. This study has demonstrated that most of these derivatives have greater pro-apoptotic activity than MIM1. We have also established the structure-activity relationship leading to classify these molecules as “Mcl-1 inhibitors” or as “dual inhibitors” of Mcl-1 and Bcl-xL.The second part of my project was focused on the preclinical evaluation of Pyridoclax hydrochlorid. We have analyzed the antitumor activity of Pyridoclax hydrochlorid in several subcutaneous xenografts derived from human ovarian cancer cell lines (IGROV1-R10, SKOV-3 and A2780). Different routes of Pyridoclax hydrochlorid administration were tested (oral, IV and IT) and its antitumor effect was analyzed at different doses as single agent or in combination with ABT-263 (100mg/kg). This study highlighted an effective antitumor activity of 20mg/kg of Pyridoclax hydrochlorid administered intravenously as single agent in two of three xenograft models without any side effects. This results open up interesting perspectives for the clinical use of Mcl-1 inhibitors to improve the clinical management of ovarian cancer
22

Développement d'une sonde intracérébrale à pixels actifs pour l'imagerie bêta du cerveau du rat libre de ses mouvements / Development of an Intracerebral Probe with Active Pixels for Beta Imaging of the Freely-moving Rat Brain

Ammour, Luis 18 December 2018 (has links)
Au cours des 20 dernières années, de nombreux modèles animaux ont émergé, permettant le développement de nouvelles approches pour l'étude préclinique du cerveau sain et pathologique. Les rongeurs sont ainsi devenus des acteurs incontournables des avancées thérapeutiques. Dans ce contexte, l'imagerie radioisotopique, qui permet de quantifier des traceurs radioactifs avec une sensibilité excellente, constitue un outil de choix l'étude des processus cérébraux in vivo. Mais, jusqu'à présent, les techniques de radioimagerie les plus courantes imposent l'anesthésie ou l'immobilisation de l'animal. Or, les anesthésiants affectent les processus biologiques étudiés. De plus, il existe un vif intérêt pour l'étude simultanée du comportement de l'animal. L'acquisition d'une image dynamique des processus cérébraux concomitante à la mesure du comportement de l'animal éveillé et libre de ses mouvements est une information précieuse pour l'étude de l'addiction, de la mémoire, etc.À IMNC, nous avons abordé la neuroimagerie comportementale par une approche originale basée sur des sondes intracérébrales qui mesurent la concentration du traceur radioactif par détection directe des positons in situ. La sonde PIXSIC, basée sur un capteur pixelisé à diodes de silicium, a démontré leur pertinence dans le cadre d'études pharmacologiques chez l'animal totalement libre de ses mouvements. Toutefois, PIXSIC a montré quelques limitations pour son utilisation longitudinale : un niveau de bruit élevé dû aux perturbations électromagnétiques, une forte sensibilité au rayonnement gamma d'annihilation et une grande fragilité mécanique de l'implant aminci à 200 micromètres. En nous appuyant sur l'avènement des technologies CMOS pour la détection des particules chargées en physique des hautes énergies, nous avons pour ambition de concevoir MAPSSIC, une sonde qui réponde aux difficultés mises en avant par PIXSIC. Les capteurs CMOS permettent d'inclure l'amplification au niveau des pixels, limitant ainsi le bruit d'origine électromagnétique. Le volume sensible peut être réduit à une épaisseur de quelques dizaines de micromètres, réduisant ainsi fortement la sensibilité aux gammas et autorisant l'augmentation de son épaisseur totale pour assurer sa robustesse mécanique. Enfin, les capteurs CMOS nous permettent de concevoir un détecteur fortement pixelisé pour accéder à de nouvelles capacités d'imagerie. Cette thèse a eu pour objectif de développer une version optimisé de la sonde. Pour cela, nous avons imaginé un premier prototype de capteur CMOS et nous avons développé un modèle Monte Carlo pour estimer ses propriétés de détection. Nous avons pu démontrer que ses performances le qualifiait pour l'usage prévu. Notamment en terme de sensibilité, de volume d’isoefficacité et d’énergie déposée. Nous avons également pu explorer plusieurs paramètres d’optimisation, les dimensions des pixels et l’épaisseur de la zone sensible, qui nous permettent de considérer MAPSSIC au delà du premier prototype. Fort de ces bases théoriques nous avons conçu plusieurs exemplaires du capteur. Les développements qui ont été établis durant la thèse se sont ensuite focalisés sur un ensemble d'outils méthodologiques, logiciels et matériels afin de permettre la caractérisation physique du capteur à l'aide de sources radioactives. Nous avons pu établir l'uniformité de la réponse des pixels et la plage de taux d’évènements assurant la linéarité du taux de comptage. Ces éléments nous ont permis de conclure sur la pertinence de ce capteur pour la conception d'un dispositif autonome d'imagerie. Celui-ci est constitué d'un implant fait de deux capteurs dos-à-dos, d'un système électronique assurant le contrôle des capteurs, la lecture du signal et la communication sans fil et d'une station d'acquisition. Dans le cadre de la thèse, nous avons montré son adéquation pour l'évaluation des variations de l'activité d'une source radioactive bêta+ liquide dans laquelle l'implant a été plongé. / Over the last 20 years, many animal models have emerged, allowing the development of new approaches for the preclinical study of the healthy and pathological brain. Rodents have become key players in therapeutic advances. In this context, radioisotope imaging, which quantifies radioactive tracers with excellent sensitivity, is a prime tool for the study of brain processes in vivo. But so far, the most common radioimaging techniques require anesthesia or immobilization of the animal. However, anesthetics affect the biological processes studied. In addition, there is a keen interest in the simultaneous study of the behavior of the animal. The acquisition of a dynamic image of brain processes concomitant with the behavior of the awake and freely moving animal is valuable information for the study of addiction, memory, etc.At IMNC lab, we have approached behavioral neuroimaging with an original method based on intracerebral probes that measure the concentration of the radioactive tracer by direct detection of positrons in situ. The PIXSIC probe, based on a pixelized sensor with silicon diodes, demonstrated their relevance in the context of pharmacological studies with completely freely moving animals. However, PIXSIC has shown some limitations for its longitudinal use: a high level of noise due to electromagnetic perturbations, a high sensitivity to annihilation gamma radiation and a high mechanical fragility of the implant thinned to 200 microns.Based on the advent of CMOS technologies for the detection of charged particles in high energy physics, our ambition is to design MAPSSIC, a probe that responds to the difficulties highlighted by PIXSIC. CMOS sensors allows amplification at the pixel level, thus limiting electromagnetic noise. The sensitive volume can be reduced to a thickness of a few tens of microns, thus greatly reducing the sensitivity to gammas and allowing the increase of its total thickness to ensure its mechanical robustness. Finally, CMOS sensors allows us to design a highly pixelated detector to reach new imaging capabilities. This thesis aims to develop an optimized version of the probe. We imagined a first prototype CMOS sensor and we developed a Monte Carlo model to estimate its detection properties. We were able to show that his performances qualified it for the intended use, in terms of sensitivity, isoefficiency volume and deposited energy. We have also been able to explore several optimization parameters, the pixel dimensions and the thickness of the sensitive area, which allow us to consider MAPSSIC beyond the first prototype. With these theoretical bases we have produced several copies of the sensor. The developments that were established during the thesis then focused on a set of methodological tools, software and hardware to allow the physical characterization of the sensor using radioactive sources. We have been able to establish the uniformity of the pixel response and the event rate range ensuring the linearity of the count rate.These elements allowed us to conclude on the relevance of this sensor for the design of an autonomous imaging device. This consists of an implant made of two back-to-back sensors, an electronic system providing sensor control, signal reading and wireless communication and an acquisition station. In the context of the thesis, we have shown its suitability for the evaluation of the variations of the activity of a liquid beta+ radioactive source in which the implant has been immersed.
23

Anti-VEGFA therapy reduces tumor growth and extends survival in a murine model of ovarian granulosa cell tumor

Tsoi, Mayra 09 1900 (has links)
Les tumeurs des cellules de la granulosa (GCTs) sont des tumeurs avec un potentiel malin ayant tendance à récidiver, provoquant ainsi la mort dans 80% des cas de stade avancé consécutif à une rechute. Bien que les GCTs représentent 5% des tumeurs ovariennes, peu d’études ont évalué les protocoles de traitement adjuvant pour la maladie avancée ou récurrente. Notre but était d’évaluer l’efficacité de la voie de signalisation du facteur de croissance de l’endothélium vasculaire A (VEGFA) comme cible pour le traitement de la GCT utilisant le modèle murin transgénique Ptentm1Hwu/tm1Hwu; Ctnnb1tm1Mmt/+; Amhr2tm3(cre)Bhr/+ (PCA) qui reproduit le stade avancé de la maladie humaine. Un anticorps anti-VEGFA a été administré une fois par semaine par voie intrapéritonéale (IP) à partir de 3 semaines d’âge. La thérapie anti-VEGFA a permis une réduction de la taille des tumeurs à 6 semaines d’âge (p<0.05) et une prolongation de la survie des animaux traités, lorsque comparé aux animaux contrôles. L’analyse des GCTs a montré une réduction significative de la prolifération cellulaire (p<0.05) et de la densité microvasculaire (p<0.01) mais aucune différence significative n’a été détectée dans l’apoptose cellulaire. p44/p42 MAPK, un effecteur de la signalisation pour le récepteur 2 de VEGFA (VEGFR2) associé à la prolifération cellulaire, était moins activé dans les tumeurs traitées (p<0.05). Par contre, l’activation d’AKT, un effecteur impliqué dans la survie cellulaire, était similaire d’un groupe à l’autre. Ces résultats suggèrent que l’anticorps anti-VEGFA réduit la prolifération cellulaire et la densité microvasculaire chez les souris PCA par inhibition de la voie de signalisation VEGFR2-MAPK, inhibant ainsi la croissance tumorale. En conclusion, l’efficacité de la thérapie anti- VEGFA mérite d’être évaluée en essais contrôlés randomisés pour le traitement des GCTs chez l’homme. / Ovarian granulosa cell tumors (GCTs) are potentially malignant tumors that have a tendency for late recurrence and cause death in 80% of women with advanced GCT due to recurrent disease. Although GCTs represent 5% of ovarian tumors in women, few studies have evaluated adjuvant treatment protocols for advanced or recurrent disease. Our goal was to determine the potential of targeting the vascular endothelial growth factor A (VEGFA) signaling pathway for the treatment of GCT. We used a genetically engineered mouse model, Ptentm1Hwu/tm1Hwu; Ctnnb1tm1Mmt/+; Amhr2tm3(cre)Bhr/+ (PCA), which imitates the advanced human disease. A monoclonal anti-VEGFA antibody was administered by intra-peritoneal injection once a week beginning at 3 weeks of age. Anti-VEGFA therapy significantly decreased tumor weights by 6 weeks of age (p<0.05) and increased survival in treated animals in comparison to controls. Significant decreases in tumor cell proliferation (p<0.05) and microvessel density (p<0.01), but no significant difference in apoptosis was found in PCA tumors. p44/p42 MAPK, a VEGFA receptor 2 (VEGFR2) signaling effector associated with cell proliferation, was significantly less activated in anti-VEGFA-treated tumors (p<0.05). In contrast, AKT activation, a VEGFR2 signaling effector associated with cell survival was similar among all groups. These results suggest that anti-VEGFA therapy effectively reduces cell proliferation and microvessel density in PCA mice by inhibition of the VEGFR2-MAPK pathway, resulting in inhibition of GCT growth. We conclude that anti-VEGFA therapy merits further investigation in the form of controlled randomized trials for the treatment of human GCT.
24

Greffons rénaux issus des donneurs décédés par arrêt circulatoire : optimisation du reconditionnement chez le donneur et de la conservation hypothermique / Kidney grafts from deceased after circulatory death donors : improving reconditioning in the donor and hypothermic preservation

Allain, Géraldine 21 December 2018 (has links)
La transplantation est la meilleure alternative en cas d'insuffisance rénale terminale. Face à la pénurie de greffons, les équipes de transplantation se sont tournées notamment vers les donneurs décédés par arrêt circulatoire (DDAC) non contrôlés. Ces greffons soumis à une période d'ischémie chaude sont plus fragiles. Des méthodes de reconditionnement chez le donneur par refroidissement in situ (RIS) et circulation régionale normothermique (CRN) se sont développées afin de réduire les lésions d'ischémie-reperfusion. Le choix de la méthode est laissé à l'appréciation de chaque équipe et il existe une grande hétérogénéité des pratiques. Après prélèvement, l'utilisation des machines de perfusion hypothermique (MPH) est généralement recommandée. L'optimisation de ces phases de reconditionnement chez le donneur et de conservation hypothermique apparait comme un enjeu majeur de santé publique. Concernant l'optimisation du mode de reconditionnement, la mise au point d'un modèle préclinique porcin parfaitement reproductible a permis de mettre en évidence une supériorité de la CRN sur le RIS. Une durée de CRN de 4 heures minimum sans dépasser 6 heures paraît optimale. Concernant la conservation hypothermique, les MPH permettent le maintien du niveau d'expression des gènes retrouvé en fin de CRN. L'ajout d'une oxygénation active en MPH ou de curcumine en solution statique améliore le devenir du greffon à court et long termes dans un modèle préclinique d'autogreffe. Ce travail pourrait s'étendre à l'étude d'autres organes, d'autres durées d'ischémie chaude et aux DDAC contrôlés afin d'élargir encore le nombre d'organes éligibles à la transplantation. / Transplantation is the best alternative to end-stage renal disease. The shortage of grafts led the transplant teams to consider uncontrolled deceased donors after circulatory death (DCDs). These grafts suffered from a period of warm ischemia and are more vulnerable. Reconditioning methods in the donor by in situ cooling (ISC) and normothermic regional perfusion (NRP) have been developed to reduce the ischemia-reperfusion injuries. Each team has the choice as to the method and there are many different practices. After removal of kidneys, the use of hypothermic perfusion machines (HPM) is generally recommended. The optimization of reconditioning in the donor and hypothermic preservation appears as a major public health challenge. About optimization of the reconditioning method, the development of a high reproducible preclinical porcine model allowed to highlight the superiority of RNP over ISC. NRP duration of 4 hours minimum without exceeding 6 hours seems optimal. About hypothermic preservation, HPM allows to maintain the level of expression of the genes found at the end of RNP. The addition of active oxygenation to HPM or curcumin in static solution improves the graft outcomes in the short and long terms in a preclinical model of auto transplantation. This work could be extended to the study of other organs, other durations of warm ischemia and to controlled DCDs in order to further increase the number of transplantable grafts.
25

Co-registration of fluorescence diffuse optical tomography (fDOT) with Positron emission tomography (PET) and development of multi-angle fDOT / Recalage d’image de la tomographie optique diffuse de fluorescence (fDOT) et la tomographie par émission de positons (TEP) et le développement de tomographie optique en multi-angle

Tong, Xiao 24 October 2012 (has links)
Ce travail de thèse concerne le traitement d’image fDOT (fDOT pour fluorescence diffuse optical tomography) suit vers deux axes. Le recalage d'images fDOT à l’aide de l’imagerie TEP (tomographie par émission de positons) et l’amélioration des reconstructions fDOT à l’aide de miroirs pour collecter des projections complémentaires. Il est présenté en deux parties : Dans la première partie, une méthode automatique pour recaler les images de fDOT avec les images de Tomographie par Emission de Positons (TEP) développée dans le but de corréler l’ensemble des informations issues de chaque modalité. Cette méthode de recalage est basée sur une détection automatique de marqueurs fiduciaires présents dans les deux modalités. La particularité de cette méthode est l’utilisation de l’image de surface obtenue en fDOT, qui sert à identifier la position en Z des marqueurs fiduciaires dans les images optiques. Nous avons testé cette méthode sur un modèle de souris porteuses de xénogreffes de tumeurs de cellules cancéreuses MEN2A qui imitent un carcinome thyroïdien médullaire humain, après une double injection de traceur radioactif : [18F]2-fluoro-2-Deoxy-D-glucose (FDG) pour l’imagerie TEP et un traceur optique d’infrarouge fluorescent, le Sentidye. Grâce à la précision de notre méthode, nous arrivons à démontrer que le signal Sentidye est présent à la fois dans la tumeur et les vaisseaux environnants [1]. La qualité des images fDOT est dégradée selon l’axe Z du fait d’un nombre limité de projections pour la reconstruction. Dans la deuxième partie, le travail s’est orienté vers une nouvelle méthode de reconstruction d’images fDOT à partir d’un nouveau système d’acquisition multi-angulaire avec deux miroirs placés de chaque côté de l’animal. Ce travail a été mené en collaboration avec le département CS d’University College London (UCL), partenaire du projet Européen FMT-XCT. Le logiciel TOAST développé par cette équipe a été utilisé comme source pour l’algorithme de reconstruction, et modifié pour s’adapter à notre problématique. Après plusieurs essais concernant l’ajustement des paramètres du programme, nous avons appliqué cette méthode sur un fantôme réaliste des tissus biologiques et chez la souris. Les résultats montrent une amélioration de l’image reconstruite d’un fantôme semi-cylindrique et de l’image de rein chez la souris, pour lesquelles la méthode des miroirs est supérieure à la méthode classique sans miroir. Malgré tout, nous avons observé que les résultats étaient très sensibles à certains paramètres, d’où une performance de reconstruction variable d’un cas à l’autre. Les perspectives futures concernent l’optimisation des paramètres afin de généraliser l’approche multi-angle. / This thesis concerns the image processing of fluorescence diffuse optical tomography (fDOT), following two axes: FDOT image co-registration with PET (positron emission tomography) image and improvement of fDOT image reconstructions using mirrors to collect additional projections. It is presented in two parts:In the first part, an automatic method to co-register the fDOT images with PET images has been developed to correlate all the information from each modality. This co-registration method is based on automatic detection of fiducial markers (FM) present in both modalities. The particularity of this method is the use of optical surface image obtained in fDOT imaging system, which serves to identify the Z position of FM in optical images. We tested this method on a model of mice bearing tumor xenografts of MEN2A cancer cells that mimic a human medullary thyroid carcinoma, after a double injection of radiotracer [18F] 2-fluoro-2-Deoxy-D-glucose ( FDG) for PET imaging and optical fluorescent infrared tracer Sentidye. With the accuracy of our method, we can demonstrate that the signal of Sentidye is present both in the tumor and surrounding vessels.The fDOT reconstruction image quality is degraded along the Z axis due to a limited number of projections for reconstruction. In the second part, the work is oriented towards a new method of fDOT image reconstruction with a new multi-angle data acquisition system in placing two mirrors on each side of the animal. This work was conducted in collaboration with the CS Department of University College London (UCL), a partner of the European project FMT-XCT. TOAST software developed by this team was used as source code for the reconstruction algorithm, and was modified to adapt to the concerned problem. After several tests on the adjustment of program parameters, we applied this method on a phantom that simulating the biological tissue and on mice. The results showed an improvement in the reconstructed image of a semi-cylindrical phantom and the image of mouse kidney, for which the reconstruction of the mirrors geometry is better than that of conventional geometry without mirror. Nevertheless, we observed that the results were very sensitive to certain parameters, where the performance of reconstruction varies from one case to another. Future prospectives concern the optimization of parameters in order to generalize the multi-angle approach.
26

Conception, reconstruction et évaluation d'une géométrie de collimation multi-focale en tomographie d'émission monophotonique préclinique / Design, reconstruction and evaluation of multi-focal collimation in single photon emission computed tomography for small-animal imaging

Benoit, Didier 05 December 2013 (has links)
La tomographie d'émission monophotonique (TEMP) dédiée au petit animal est une technique d'imagerie nucléaire qui joue un rôle important en imagerie moléculaire. Les systèmes TEMP, à l'aide de collimateurs pinholes ou multi-pinholes, peuvent atteindre des résolutions spatiales submillimétriques et une haute sensibilité pour un petit champ de vue, ce qui est particulièrement attractif pour imager des souris. Une géométrie de collimation originale a été proposée, dans le cadre d'un projet, appelé SIGAHRS, piloté par la société Biospace. Ce collimateur présente des longueurs focales qui varient spatialement dans le plan transaxial et qui sont fixes dans le plan axial. Une haute résolution spatiale est recherchée au centre du champ de vue, avec un grand champ de vue et une haute sensibilité. Grâce aux simulations Monte Carlo, dont nous pouvons maîtriser tous les paramètres, nous avons étudié cette collimation originale que nous avons positionnée par rapport à un collimateur parallèle et un collimateur monofocal convergent. Afin de générer des données efficacement, nous avons développé un module multi-CPU/GPU qui utilise une technique de lancer de rayons dans le collimateur et qui nous a permis de gagner un facteur ~ 60 en temps de calcul, tout en conservant ~ 90 % du signal, pour l'isotope ⁹⁹^mTc (émettant à 140,5 keV), comparé à une simulation Monte Carlo classique. Cependant, cette approche néglige la pénétration septale et la diffusion dans le collimateur. Les données simulées ont ensuite été reconstruites avec l'algorithme OSEM. Nous avons développé quatre méthodes de projection (une projection simple (S-RT), une projection avec volume d'intersection (S-RT-IV), une projection avec calcul de l'angle solide (S-RT-SA) et une projection tenant compte de la profondeur d'interaction (S-RT-SA-D)). Nous avons aussi modélisé une PSF dans l'espace image, anisotrope et non-stationnaire, en nous inspirant de la littérature existante. Nous avons étudié le conditionnement de la matrice système pour chaque projecteur et collimateur, et nous avons comparé les images reconstruites pour chacun des collimateurs et pour chacun des projecteurs. Nous avons montré que le collimateur original proposé est le système le moins bien conditionné. Nous avons aussi montré que la modélisation de la PSF dans l'image ainsi que de la profondeur d'intéraction améliorent la qualité des images reconstruites ainsi que le recouvrement de contraste. Cependant, ces méthodes introduisent des artefacts de bord. Comparé aux systèmes existants, nous montrons que ce nouveau collimateur a un grand champ de vue (~ 70 mm dans le plan transaxial), avec une résolution de 1,0 mm dans le meilleur des cas, mais qu'il a une sensibilité relativement faible (1,32x10⁻² %). / Small animal single photon emission computed tomography (SPECT) is a nuclear medicine imaging technique that plays an important role in molecular imaging. SPECT systems using pinhole or multi-pinhole collimator can achieve submillimetric spatial resolution and high sensitivity in a small field of view, which is particularly appropriate for imaging mice. In our work, we studied a new collimator dedicated to small animal SPECT, in the context of a project called SIGAHRS, led by the Biospace company. In this collimator, focal lengths vary spatially in the transaxial plane and are fixed in the axial plane. This design aims at achieving high spatial resolution in the center of the field of view, with a large field of view and high sensitivity. Using Monte Carlo simulations, where all parameters can be controlled, we studied this new collimator geometry and compared it to a parallel collimator and a cone-beam collimator. To speed up the simulations, we developed a multi-CPU/GPU module that uses a technique of ray tracing. Using this approach, the acceleration factor was ~ 60 and we restored ~ 90 % of the signal for ⁹⁹^mTc (140.5 keV emission), compared to a classical Monte Carlo simulation. The 10 % difference is due to the fact that the multi-CPU/GPU module neglects the septal penetration and scatter in the collimator. We demonstrated that the data acquired with the new collimator could be reconstructed without artifact using an OSEM algorithm. We developed four forward projectors (simple projector (S-RT), projector accounting for the surface of the detecting pixel (S-RT-IV), projection modeling the solid angle (S-RT-SA) of the projection tube, and projector modeling the depth of interaction (S-RT-SA-D)). We also modeled the point spread function of the collimator in the image domain, using an anisotropic non-stationary function. To characterize the reconstruction, we studied the conditioning number of the system matrix for each projector and each collimator. We showed that the new collimator was more ill-conditioned than a parallel collimator or a cone-beam collimator. We showed that the image based PSF and the modeling of the depth of interaction improved the quality of the images, but edge artefacts were introduced when modeling the PSF in the image domain. Compared to existing systems, we showed that this new collimator has a large field of view (~ 70 mm in the transaxial plane) with a resolution of 1.0 mm in the best case but suffers from a relatively low sensitivity (1.32x10⁻² %).
27

Marquage de molécules biologiques par des complexes de radiométaux à base de polyamines macrocycliques

Moreau, Mathieu 24 April 2012 (has links) (PDF)
Ce travail de thèse réalisé à l'Institut de Chimie Moléculaire de l'Université de Bourgogne porte dans un premier temps sur la synthèse d'agents chélatants bifonctionnels adaptés à la chélation de radiométaux trivalents, notamment l'indium-111. La plus grande partie de ce travail a ensuite consisté à réaliser le greffage d'un agent chélatant bifonctionnel dérivé du DOTA sur différents anticorps ou fragments d'anticorps monoclonaux : le trastuzumab (anti HER2, traitement de cancers du sein), le cétuximab (anti EGFR, traitement de nombreux cancers, dont le cancer colorectal) et l'abciximab (antiagrégant plaquettaire). Une attention particulière a été apportée à la caractérisation des différents immunoconjugués. La dernière étape de ce travail de thèse porte sur le radiomarquage à l'indium-111 de deux immunoconjugués préparés : le trastuzumab et le cétuximab. Ces étapes de radiomarquage nous ont permis de déterminer la fraction immunoréactive et l'affinité de chaque radiotraceur. Nous avons ainsi pu étudier la biodistribution in vivo de ces radiotraceurs chez la souris par imagerie SPECT-CT. Nous avons également développé une méthode de greffage originale pour le marquage d'un fragment d'anticorps de type Fab, l'abciximab, dans le but de suivre la biodistribution de cet antiagrégant plaquettaire. Enfin, nous avons également validé le concept d'imagerie multimodale à travers le greffage et le radiomarquage d'un agent bimodal pour l'imagerie optique et la SPECT sur des lipopolysaccharides bactériens. Les travaux réalisés nous ont permis d'acquérir un savoir faire en matière de greffage d'anticorps et de radiomarquage. Les résultats obtenus permettent d'envisager le greffage d'autres anticorps ou biomolécules, ainsi que l'utilisation d'autres radionucléides pour l'imagerie PET ou la radioimmunothérapie
28

Exploration de nouvelles voies thérapeutiques contre le cancer du col de l'utérus : approche combinée par adénovirus et ARN interférence

Bonetta, Anaëlle 16 January 2013 (has links) (PDF)
Le cancer du col de l'utérus est le troisième cancer le plus fréquent chez la femme, dont l'agent étiologique majeur est l'infection par les papillomavirus humain (notamment HPV-16 et 18), qui sont de petits virus infectant les épithéliums muqueux et cutanés, et pouvant induire la formation de tumeurs. L'inducteur majeur du processus oncogène est le processus d'intégration des régions codantes pour les oncoprotéines E6 et E7, au sein de la cellule hôte suite à l'infection. Elles interférent avec le cycle cellulaire et induisent notamment l'immortalisation, voire la transformation des cellules. Les fonctions les plus connue de ces deux oncoprotéines sont la dégradation des suppresseurs de tumeur p53 et pRb, respectivement. Mon travail de thèse à consisté en la mise au point des vecteurs adénoviraux exprimant des miARN dirigés contre l'oncoprotéine E6. Exprimés in vitro ils induisent l'induction de la mort cellulaire par apoptose des cellules tumorales traitées, via l'activation de la voie de caspases, et in vivo permettent le ralentissement de la croissance de tumeurs xénogreffées à des souris Nude. De plus, la stratégie thérapeutique adénovirale a montré ses extensions possibles sur d'autres types de cancers HPV-positifs, mais également via l'expression de différentes moléculaires thérapeutiques, visant à empêcher l'interaction des oncoprotéines telles qu'E6 avec leurs partenaires cellulaires et ainsi les empêcher d'exercer les activités biologiques impliquées dans le développement de cancers. Pour finir, les adénovirus peuvent également être vu comme des outils d'extinction fonctionnels d'E6 et permettant d'étudier les répercutions sur d'autres processus cellulaires.
29

Anti-VEGFA therapy reduces tumor growth and extends survival in a murine model of ovarian granulosa cell tumor

Tsoi, Mayra 09 1900 (has links)
Les tumeurs des cellules de la granulosa (GCTs) sont des tumeurs avec un potentiel malin ayant tendance à récidiver, provoquant ainsi la mort dans 80% des cas de stade avancé consécutif à une rechute. Bien que les GCTs représentent 5% des tumeurs ovariennes, peu d’études ont évalué les protocoles de traitement adjuvant pour la maladie avancée ou récurrente. Notre but était d’évaluer l’efficacité de la voie de signalisation du facteur de croissance de l’endothélium vasculaire A (VEGFA) comme cible pour le traitement de la GCT utilisant le modèle murin transgénique Ptentm1Hwu/tm1Hwu; Ctnnb1tm1Mmt/+; Amhr2tm3(cre)Bhr/+ (PCA) qui reproduit le stade avancé de la maladie humaine. Un anticorps anti-VEGFA a été administré une fois par semaine par voie intrapéritonéale (IP) à partir de 3 semaines d’âge. La thérapie anti-VEGFA a permis une réduction de la taille des tumeurs à 6 semaines d’âge (p<0.05) et une prolongation de la survie des animaux traités, lorsque comparé aux animaux contrôles. L’analyse des GCTs a montré une réduction significative de la prolifération cellulaire (p<0.05) et de la densité microvasculaire (p<0.01) mais aucune différence significative n’a été détectée dans l’apoptose cellulaire. p44/p42 MAPK, un effecteur de la signalisation pour le récepteur 2 de VEGFA (VEGFR2) associé à la prolifération cellulaire, était moins activé dans les tumeurs traitées (p<0.05). Par contre, l’activation d’AKT, un effecteur impliqué dans la survie cellulaire, était similaire d’un groupe à l’autre. Ces résultats suggèrent que l’anticorps anti-VEGFA réduit la prolifération cellulaire et la densité microvasculaire chez les souris PCA par inhibition de la voie de signalisation VEGFR2-MAPK, inhibant ainsi la croissance tumorale. En conclusion, l’efficacité de la thérapie anti- VEGFA mérite d’être évaluée en essais contrôlés randomisés pour le traitement des GCTs chez l’homme. / Ovarian granulosa cell tumors (GCTs) are potentially malignant tumors that have a tendency for late recurrence and cause death in 80% of women with advanced GCT due to recurrent disease. Although GCTs represent 5% of ovarian tumors in women, few studies have evaluated adjuvant treatment protocols for advanced or recurrent disease. Our goal was to determine the potential of targeting the vascular endothelial growth factor A (VEGFA) signaling pathway for the treatment of GCT. We used a genetically engineered mouse model, Ptentm1Hwu/tm1Hwu; Ctnnb1tm1Mmt/+; Amhr2tm3(cre)Bhr/+ (PCA), which imitates the advanced human disease. A monoclonal anti-VEGFA antibody was administered by intra-peritoneal injection once a week beginning at 3 weeks of age. Anti-VEGFA therapy significantly decreased tumor weights by 6 weeks of age (p<0.05) and increased survival in treated animals in comparison to controls. Significant decreases in tumor cell proliferation (p<0.05) and microvessel density (p<0.01), but no significant difference in apoptosis was found in PCA tumors. p44/p42 MAPK, a VEGFA receptor 2 (VEGFR2) signaling effector associated with cell proliferation, was significantly less activated in anti-VEGFA-treated tumors (p<0.05). In contrast, AKT activation, a VEGFR2 signaling effector associated with cell survival was similar among all groups. These results suggest that anti-VEGFA therapy effectively reduces cell proliferation and microvessel density in PCA mice by inhibition of the VEGFR2-MAPK pathway, resulting in inhibition of GCT growth. We conclude that anti-VEGFA therapy merits further investigation in the form of controlled randomized trials for the treatment of human GCT.
30

Multi-scale dosimetry for targeted radionuclide therapy optimisation / Dosimétrie multi-échelle pour l'optimisation de la radiothérapie interne vectorisée

Marcatili, Sara 20 October 2015 (has links)
La Radiothérapie Interne Vectorisée (RIV) consiste à détruire des cibles tumorales en utilisant des vecteurs radiomarqués (radiopharmaceutiques) qui se lient sélectivement à des cellules tumorales. Dans un contexte d'optimisation de la RIV, une meilleure détermination du dépôt d'énergie dans les tissues biologiques est primordiale pour la définition d'une relation dose absorbée - effet biologique et pour l'optimisation des traitement du cancer. Cela nécessite une évaluation quantitative de la distribution de l'activité (avec la technique d'imagerie moléculaire la plus appropriée) et d'effectuer le transport du rayonnement à l'échelle à laquelle se produisent les phénomènes biologiques pertinents. Les méthodologies à appliquer et les problématiques à établir dépendent strictement de l'échelle (cellule, tissu, organe) de l'application considérée, et du type de rayonnement en cause (photons, électrons, particules alpha). Mon travail de recherche a consisté à développer des techniques dosimétriques dédiées (dosimétrie mono-échelle) et innovantes, capables de prendre en compte la particularité de différents scénarios expérimentaux (cellulaire, pré-clinique, RIV clinique). / Targeted Radionuclide Therapy (TRT) consists in killing tumour targets by using radiolabeled vectors (radiopharmaceuticals) that selectively bind to tumour cells. In a context of TRT optimization, a better determination of energy deposition within biologic material is a prerequisite to the definition of the absorbed dose-effect relationship and the improvement of future cancer treatment. This requires being able to quantitatively assess activity distribution (with the most appropriate molecular imaging technique) and perform radiation transport at the scale at which biologically relevant phenomena occur. The methodologies that should be applied and the problematic to be faced strictly depend on the scale (cell, tissue, body) of the application considered, and on the type of radiation involved (photons, electrons, alpha). This research work consisted in developing dedicated dosimetric techniques (single-scale dosimetry) capable of taking into account the peculiarity of different experimental scenarios (cellular, pre-clinical, clinical TRT).

Page generated in 0.0678 seconds