Spelling suggestions: "subject:"prótese."" "subject:"hipóteses.""
121 |
Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro studyFábio Sanches Magalhães Tunes 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
|
122 |
Influência das desadaptações angulares unilaterais na distribuição de tensões da região peri-implantar de elementos unitários tipo UCLA submetidos a pré-carga e carga axial: estudo in vitro / Influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial loadVinicius Cappo Bianco 24 June 2013 (has links)
Atualmente, os implantes são utilizados em diversos tipos de tratamento na reabilitação oral. Para manutenção da osseointegração, é essencial que o conjunto prótese/implante/osso seja submetido a forças às quais estejam aptos a suportar. Os diferentes tipos de desadaptações das infraestruturas das próteses sobre implantes são fatores que podem contribuir para o aumento das tensões na região peri-implantar. Este estudo teve como objetivo avaliar a influência das desadaptações angulares unilaterais na distribuição de tensões na região periimplantar de pilares tipo UCLA, no momento da pré-carga e carga axial. Infraestruturas de CoCr, confeccionadas utilizando-se pilares tipo UCLA, foram divididas em quatro grupos: Grupo A (adaptado), Grupo B, Grupo C e Grupo D (50, 100 e 200 μm de desadaptação unilateral angular por vestibular, respectivamente). Cada grupo foi representado por quatro infraestruturas (n=4). Quatro implantes (4.1mm/15mm) foram posicionados em uma matriz metálica, onde posteriormente foi vazado o poliuretano (PU), com função de simular o tecido ósseo. Quatro extensômetros (strain gauges) foram posicionados na região vestibular, distal, lingual e mesial de cada implante, para aferir a quantidade de deformação; cada grupo foi posicionado em seu respectivo implante. Foram realizados dois testes: o teste de pré-carga com um torque de 32Ncm e o teste de carga com uma força axial estática de 300N. Cada infraestrutura foi sujeita aos dois testes, por cinco vezes. Para análise estatística dos dados, foram utilizados ANOVA (dois critérios) e o teste de Tukey (p<0,05). Os resultados mostraram que os grupos A e B tiveram menos deformação da região peri-implantar em ambos os testes, quando comparados aos grupos C e D. A estatística também mostrou que o Grupo A apresentou melhor distribuição de tensões em sua região, peri-implantar quando comparado aos outros três grupos (p<0,05). Como conclusões, este estudo mostrou que as desadaptações influem na distribuição das tensões da região peri-implantar e que quanto maior o nível de desadaptação, mais altas são as tensões geradas. / Nowadays implants are used in several kinds of oral rehabilitation treatments. For the osseointegration maintenance it is important that crow/implant/bone are subjected to forces which are able to withstand. Different kinds of misfit on the crown frameworks are factors that could lead to an increase of strain around the implanted bone. This study aimed to evaluate the influence of the unilateral angular misfit in frameworks made of UCLA on the peri-implant strain distribution, subjected to preload and axial load. Frameworks made of chrome-cobalt were fabricated on UCLA abutments and divided in 4 groups: Group A (no misfit), Group B, Group C, Group D (50, 100, and 200 of unilateral angular misfit by buccal side, respectively). Each group was represented for 4 frameworks (n=4). Four implants (4.1mm/15mm) were positioned in a metallic matrix which was subsequently poured the polyurethane (PU) to simulate the bone. Four strain gauges were positioned on the buccal, distal, lingual and mesial sides of each implant to assess the amount of strain, each group was connected on its respectively implant. It was performed 2 tests: the preload test with a 32Ncm torque and the load test by applying an axial force of 300N. Each framework was subjected to the both test five times. To the statistics analysis ANOVA (2 ways) and Turkeys test were performed. The results showed that the Groups A and B presented less deformation when compared to Groups C and D. The statistics also showed that the Group A presented better distribution of strain on its peri-implant bone when compared to the other three groups (p<0,05). In conclusion this study showed that misfit had influence on the strain distribution on the peri-implant bone and that strain increased on the Groups C and D which presented higher levels of misfit.
|
123 |
Análise fotoelástica das tensões ao redor dos implantes, na região de mandíbula, com aplicação de força em próteses tipo protocolo, revestidas em resina acrílica / Photoelasticity stress analysis around implants in mandible region with application of strength to Branemark protocol prosthesis covered with acrylic resinJosé Fabio Guastelli Gastaldo 19 February 2013 (has links)
Introdução: O objetivo desta pesquisa é analisar, pelo método fotoelástico, o comportamento das tensões que ocorrem nas estruturas periimplantares, em suportes de prótese fixa, segundo o protocolo de Brånemark, parafusada sobre cinco implantes, de diferentes comprimentos (10mm; 13mm e 15mm), quando submetidas às cargas oclusais. Métodos: Foram construídos três modelos fotoelásticos de mandíbulas: MD10; MD13 e MD15, com cinco implantes cada um, de 3,75mm de diâmetro, hexágono interno e posicionados paralelamente na região interforaminal. Sobre os implantes, em cada modelo, foram instalados pilares do tipo micro unit com cinta de 1mm e, sobre eles, uma única prótese, com uma infraestrutura metálica em cobalto/cromo, com cantilever de 15mm, revestida em resina acrílica. Foram aplicadas pressões de 1,0 e 3,0 bars e as imagens foram fotografadas e avaliadas. Resultados: Os resultados mostraram que as maiores tensões ocorreram nos implantes com 10mm de comprimento e o padrão de tensões se manteve nos vários comprimentos de implantes, mudando apenas a magnitude das tensões ao longo do corpo do implante. O incremento do comprimento foi relevante quanto à diminuição dos níveis de tensão na região analisada no modelo. Conclusões: Conclui-se que: 1) Os implantes de maior comprimento distribuíram melhor as tensões ao longo do corpo do implante; 2) As tensões se localizaram mais apicalmente, tanto por mesial como distal, nos implantes de maior comprimento, 3) Os implantes que sofreram maiores tensões foram os mais próximos do cantilever e o implante central. / The purpose of this study was to analyze, using the photoelasticity method, the behavior of stresses occurring in peri-implant structures and fixed prosthesis supports following Brånemark protocol that are screwed on five implants of different lengths, 10mm; 13mm and 15mm, when submitted to occlusal loads. Three mandible photoelastic models were built: MD10; MD13 and MD15, with five implants each, 3.75mm of internal diameter and located in parallel with each other in the interforaminal region. Microunit pillars were installed on each implant model with a 1mm-belt, and a single prosthesis was installed over them with a cobalt/chrome metallic infrastructure covered with thermoplastic acrylic resin. Loads of 1.0 and 3.0 bars were applied and images were photographed and evaluated. Results showed that highest tensions occurred in 10mm-length implants; the patterns of stresses was the same in implants of different lengths and only the magnitude of stresses changed along implant body. The greater the length the lower the stress in the analyzed region of the model. We concluded that: 1) The implants of greater length tension better distributed along the body of the implant. 2) Tensions were located more apically by both mesial and distal implants of greater length. 3) The implants have suffered greater tensions were the closest to the cantilever and implant center.
|
124 |
Análise biomecânica in vitro de pilares estéticos de zircônia personalizados e não personalizados / In vitro biomechanical analysis of customized and not customized aesthetic zircônia abutmentIzabela Cristina Mauricio Moris 19 May 2015 (has links)
Atualmente os implantes passaram a ser uma opção viável de tratamento para se obter uma adequada reabilitação oral, sendo que a estética tem se tornado um fator de grande importância na Odontologia. Os pilares em zircônia tem-se apresentado como uma boa alternativa que vem preencher o fator estético, não contemplado pelos pilares metálicos. O objetivo deste estudo foi avaliar a resistência à fratura dos pilares de zircônia personalizados e não personalizados e o efeito da ciclagem termomecânica sobre a adaptação marginal, perda de torque e resistência à cimentação destes pilares. Para avaliar a resistência à fratura, 18 implantes cone morse foram utilizados e estes foram divididos em três grupos: GZr: 6 conjuntos implantes/pilares em zircônia; GZrp: 6 conjuntos implante/pilares em zircônia personalizados e GTi: 6 conjuntos implante/pilares em titânio (controle). Os conjuntos implante/pilar foram submetidos à carga compressiva oblíqua em máquina universal de ensaios, com célula de carga de 500kgf e velocidade de 0,5mm/min, em angulação de 30°. Para avaliar os efeitos da ciclagem termomecânica foram utilizados 24 implantes cone morse e estes foram divididos em três grupos: GZr: 8 conjuntos implantes/pilares em zircônia; GZrp: 8 conjuntos implante/pilares em zircônia personalizados e GTi: 8 conjuntos implante/pilares em titânio (controle). Os pilares foram instalados com o torque recomendado pelo fabricante (15Ncm). Coroas cerâmicas foram confeccionadas para todos os grupos. A adaptação marginal das coroas foi avaliada antes e após a ciclagem termomecânica e a resistência de cimentação das coroas foi avaliada após a ciclagem termomecânica através do ensaio de tração. Os conjuntos foram submetidos a 1.000.000 ciclos mecânicos e 8.400 ciclos térmicos. A análise estatística utilizada para o teste de resistência à fratura foi Anova com teste complementar de Tukey. O Grupo GZrp apresentou resistência a fratura significantemente maior que GZr (p=0,009) e o GZr foi semelhante ao GTi. Para a análise da perda de torque e adaptação marginal foi utilizado o modelo linear de efeitos mistos. Para a adaptação marginala análise estatatística revelou haver diferença entre os grupos GZrp e GTi (após ciclagem p=,010) porém não houve diferença dentro do mesmo grupo nos diferentes tempos (antes e após ciclagem termomecânica). Para a perda de torque a análise estatística revelou não haver diferenças significantes, antes e após a ciclagem termomecânica, dentro dos grupos, porém entre os grupos houve diferenças estatísticas entre GZr e Gti antes da ciclagem . Para a análise da resistência de cimentação das coroas foi utilizado ANOVA e este revelou não haver diferenças significantes entre os grupos. Sendo assim, conclui-se que a personalização dos pilares de zircônia não afeta suas propriedades mecânicas, e que o comportamento dos pilares de zircônia é semelhante aos pilares de titânio o que viabiliza o seu uso clínico. / Now implants have been a viable option of treatment for reaching an adequate oral rehabilitation, once the aesthetic have become a factor of great importance in Dentistry. The zirconia abutments have appeared as a good alternative to fill the aesthetic factor that is not present in the metallic abutments. The aim of the present study was to evaluate the fracture strength of customized and not customized zirconia abutments and the effect of thermomechanical cycling in the marginal fit, torque loss and cementation resistance of these abutments. For fracture strength evaluation, 18 morse taper implants were used and divided into three groups: GZr: 6 sets of implants/zirconia abutments; GZrp: 6 sets of implants/customized zirconia abutments and GTi: 6 sets of implants/titanium abutments (control). The sets were submitted to compressive oblique loading in universal testing machine, with a load cell of 500kgf and 0.5mm/min speed, in a 30 degree angulation. For evaluation of the thermomechanical cycling effect, 24 morse taper implants were used and divided into three groups: GZr: 8 sets implants/zirconia abutments; GZrp: 8 sets implants/customized zirconia abutments and GTi: 8 sets implants/titanium abutments (control). The abutments were installed with the torque recommended by the manufacturer (15Ncm). Ceramic crowns were made for all groups. The marginal fit of crowns was evaluated before and after thermomechanical cycling and the cementation resistance of crowns was evaluated after thermomechanical cycling by tensile strength test. The sets were submitted to 1,000,000 mechanical cycles and 8,400 thermal cycles. The fracture strength data were statistically analyzed by ANOVA and Tukey\'s test. The GZrp group presented fracture strength statistically greater than GZr (p=.009) and GZr was similar to GTi. Marginal fit and torque loss data were analyzed by mixed linear model. In the marginal fit, significant difference was noted between GZrp and GTi (after: p=.010), but no difference was noted in the group at different times (before and after thermomechanical cycling).For torque loss, no significant difference was noted before and after thermomechanical cycling in the groups, but significant difference was noted between Gzrp and GTi after thermomechanical cycling. Cementation resistance of crowns was analyzed by ANOVA and no significant difference was noted among the groups. Thus, it was concluded that customization of zirconia abutments does not affect their mechanical properties, and the behavior of zirconia abutments is similar to titanium ones, enabling its clinical use.
|
125 |
Estudo comparativo da resistência mecânica da poliuretana derivada do óleo da mamona, submetida à ensaio de tração / not availableDenise Loureiro Vianna 31 July 1997 (has links)
Com vistas à sua utilização na confecção de luvas para revestimento de soquetes de próteses para amputações infrapatelares, a resistência mecânica da poliuretana derivada da combinação do óleo da mamona purificado (poliol) com o pré-polímero difenilmetanodiisocianato foi testada por meio de ensaios de tração numa máquina universal de ensaios, comparativamente com dois outros tipos de material, o elastômero de silicone e a espuma de borracha, de uso corrente para a mesma finalidade. A poliuretana e o elastômero de silicone foram também testados em uma forma associada com uma alma de malha tubular de poliamida, totalizando cinco tipos de materiais investigados, com os quais se confeccionaram corpos de prova com o formato de \"gravata borboleta\". Foram considerados parâmetros para a análise a carga máxima suportada, a tensão máxima, a tensão de ruptura, o alongamento até a ruptura e o módulo de elasticidade, de cada material. Os ensaios foram realizados segundo padronização pela norma ASTM 638-M. Os resultados mostraram que o silicone com e sem a alma de malha tubular de poliamida foi o material mais resistente e que a poliuretana derivada do óleo da mamona apresentou resistência próxima à da espuma de borracha, quando pura, e próxima à do silicone puro, quando associada à malha tubular . O silicone puro foi o material com a maior capacidade de alongamento até ruptura, sendo a poliuretana pura o material com a menor capacidade de alongamento. Entretanto, quando associados à alma de malha tubular, ambos passaram a ter a mesma capacidade de alongamento, que ficou reduzida em relação àquela dos materiais puros. Concluiu-se que, apesar de menos resistente no estado puro, a poliuretana derivada do óleo da mamona pode ter sua resistência aprimorada com a associação da malha tubular, mantendo-se ainda mais flexível e com melhor capacidade de absorção e distribuição de carga que o silicone, sendo, portanto, um material adequado para a confecção de luvas para revestimento de soquetes de próteses para amputação do membro inferior. / With a view to using it as lining material for below knee prosthesis, the mechanical resistance of a poliurethane derived from the combination of purified castor oil with the prepolymer diphenylmethandiisocyanate was tested by means of tensile strength measurement in a universal testing machine, as compared with two other materials, the silicone elastomer and the synthetic rubber foam, both of current use for the same purpose. The castor oil polyurethane and the silicone elastomer were tested either in a plain form and combined with of a polyamid mesh core, summing up five types of material investigated. Bow-tie shaped specimens were cut out of all materials, so as to conform with the requirements of ASTM 638-N standard. The parameters taken into consideration for analysis were the maximal load supported, the maximal tension, the tension at rupture, the elongation at rupture and the modulus of elasticity for each material. The results showed that the silicone elastomer with and without the mesh core was the most resistant material and that the resistance of the plain castor oiI polyurethane is close to that of rubber foam. When combined with the mesh core, the resistance of the polyurethane became similar to that of the plain silicone elastomer. The plain silicone elastomer showed the greatest capacity of elongation before it eventually ruptured, whilst the castor oil polyurethane ruptured much earlier than the rubber foam, in a intermediate position according to this parameter. However, when combined with the mesh core, both silicone elastomer and castor oiI polyurethane presented the same capacity of elongation, which was reduced in comparison to both materials in the plain state. It was concluded that, despite being weaker, the resistance of castor oil polyurethane can be increased by the combination with the mesh core, still preserving its greater flexibility and shock absorbing and load distribution capacity, as compared to the silicone elastomer. In this form it is, therefore, an adequate material to make soft sockets for below knee prostheses.
|
126 |
Uso de sacaffolds de Poli L Lactide e de Poli L Lactide com hidroxiapatita em calota craniana : modelo experimental em ratos Wistar / Use of sacaffolds of Poly L Lactide and Poly L Lactide with hydroxyapatite in skullcap : experimental model in Wistar ratsBasso, Rafael de Campos Ferreira, 1974- 24 August 2018 (has links)
Orientador: Paulo Kharmandayan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T15:54:40Z (GMT). No. of bitstreams: 1
Basso_RafaeldeCamposFerreira_M.pdf: 2923257 bytes, checksum: a229be9baca0180070629eab5f5e76d1 (MD5)
Previous issue date: 2014 / Resumo: O tratamento de deformidades no corpo humano, principalmente deformidades ósseas craniofaciais, sejam elas causadas por trauma, infecções, deformidades congênitas ou pós exerese tumorais, continua sendo, nos dias atuais, um grande desafio ao cirurgião. Sabe-se que os enxertos de tecidos autólogos são o padrão ouro para essas reparações, porém, é notável a escassez de áreas doadoras. Nos últimos anos, com o avanço da engenharia de tecidos usando cultura de células semeadas em implantes, tem aumentado vertiginosamente a procura por polímeros biorreabsorvíveis que possam ser considerados ideais para fabricação de moldes, conhecidos cientificamente como scaffolds, carreadores de células capazes de recompor defeitos causados por perdas teciduais. O presente experimento objetiva estudar, experimentalmente, o uso de placas de Poli L Lactide (PLLA) e Poli L Lactide associada à Hidroxiapatita (PLLA + HA), obtidas por rotofiação (rotary jet spinning), como uma possibilidade de oferecer scaffolds de boa qualidade para colaborar com o avanço da engenharia tecidual. Para isso, utilizou-se 30 ratas da raça Wistar, distribuídas em 3 grupos,nas quais foram realizados defeitos críticos na calota craniana. Em seguida foram implantados scaffolds de PLLA e PLLA + HA e comparados com o grupo controle, que não recebeu implante. Os resultados mostraram que nos casos em que apenas foram realizados os defeitos nas calotas cranianas, não ocorreram a cicatrização óssea. Nos casos em que os scaffolds de PLLA e de PLLA + HA foram usados, notou-se rica neovascularização, acompanhada de reação do tipo corpo estranho e presença de osso reativo ao redor dos implantes / Abstract: The treatment of deformities in the human body, especially craniofacial bone deformities, whether caused by trauma, infection, congenital or due to resection tumors, remains, nowadays, a great challenge to the surgeon. It is known that autologous tissue grafts is the gold standard for these repairs, however, it is remarkable the scarcity of donor areas. During the last years, with the improvement of tissue engineering using cell culture growth in implants, has increased dramatically the search for an ideal polymer that can be used as a mold, known as scaffolds, for cell attachment and thus enabling the recomposition of defects caused by tissue loss. The present experiment aims to study experimentally the use of Poly L-Lactide(PLLA) plates and Poly L-Lactide(PLLA) associated with Hydroxyapatite (HA), obtained by Rotary Jet spinning, as a possibility to provide scaffolds with good quality and affordable costs to collaborate with the tissue engineering advancement. For this, were used 30 Wistar rats, distributed into 3 groups, in which critical defects were performed in the skull. Then scaffolds of PLLA and PLLA + HA (groups 2 and 3) were implanted and compared with the control group that didn¿t receive implant (group 1). The results have shown that in cases where only the defects in cranial caps were done, bone healing have not occurred. In cases where the scaffolds of PLLA and PLLA+ HA were used, rich neovascularization was noted, accompanied by foreign body type reaction and presence of reactive bone around the implants / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências
|
127 |
A influência da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento no sistema implantossuportado = Influence of mechanical cycling on marginal misfit, strain and loosening torque in the implant-supported system / Influence of mechanical cycling on marginal misfit, strain and loosening torque in the implant-supported systemMarques, Isabella da Silva Vieira, 1986- 23 August 2018 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:57:52Z (GMT). No. of bitstreams: 1
Marques_IsabelladaSilvaVieira_M.pdf: 2460672 bytes, checksum: c23d88013ae75d0941f8cc574887e9dc (MD5)
Previous issue date: 2013 / Resumo: O objetivo neste estudo foi avaliar a influência da ciclagem mecânica no torque de afrouxamento de parafusos protéticos, no desajuste marginal e na transmissão de tensões ao sistema prótese-implante. Foram confeccionadas 10 infraestruturas metálicas fundidas em titânio comercialmente puro, simulando próteses parciais fixas (PPF) de três elementos retidas por dois implantes e próteses totais fixas (PTF) retidas por cinco implantes. A partir das infraestruturas enceradas e fundidas, foram confeccionados modelos que deram origem aos 3 grupos de avaliação (n = 10): grupo I (pré-fundição), grupo II (adaptado) e grupo III (desajuste simulado), tanto para a PPF quanto para a PTF. Para cada modelo de trabalho (resina) confeccionado, foram avaliados o desajuste marginal e torque de afrouxamento, antes e após a ciclagem mecânica (1 milhão de ciclos mecânicos, 2 Hz, 280 N). Os torques de afrouxamento iniciais dos parafusos protéticos e dos parafusos de mini abutments foram mensurados 24 horas após a aplicação do torque (10 Ncm e 20 Ncm, respectivamente) utilizando um torquímetro digital. O teste do parafuso único foi realizado e o desajuste vertical foi quantificado por meio de microscópio óptico. As tensões geradas aos análogos durante a fixação da infraestrutura foram avaliadas em um modelo de gesso utilizando strain gauges, sendo cada infraestrutura parafusada ao modelo com um torque padronizado de 10 Ncm. Os resultados obtidos foram submetidos à análise exploratória seguida dos testes estatísticos ANOVA e Tukey (? = 0,05) quando obtidos dados paramétricos e Mann Whitney e Wilcoxon quando encontrados dados não paramétricos. Para todos os grupos avaliados, a ciclagem mecânica não apresentou diferença significativa quando analisados torque de afrouxamento dos parafusos protéticos, desajuste e tensão, porém houve um aumento nos valores médios de torque de afrouxamento dos mini abutments nos grupos II e III para a PPF e no grupo III para a PTF. O teste de correlação de Pearson (? = 0,05) indicou correlação positiva entre desajuste e tensão para todas as situações avaliadas e ainda correlação negativa entre torque de afrouxamento e desajuste vertical, para os grupos II e III de ambos os designs protéticos. Dentro das condições avaliadas e resultados obtidos, pode-se concluir que a ciclagem mecânica de infraestruturas de próteses múltiplas parafusadas não exerce influência relevante sobre o torque de afrouxamento, desajuste e tensão. Os parafusos protéticos apresentam maior tendência ao afrouxamento em próteses mal adaptadas. Próteses desadaptadas geram maior tensão ao sistema prótese-implante / Abstract: The aim of this study was to evaluate the influence of cyclic loading on loosening torque, misfit and strain transmitted to prosthesis-implant system. Ten Commercially pure titanium frameworks were casted simulating fixed partial dentures (FPD) of three elements retained by two implants and mandibular full-arch fixed prostheses (FFP) as bars retained by five implants. From the waxed and casted frameworks, models were fabricated, which resulted in three evaluation groups (n = 10): group I (pre-casting), group II (passive fit) and group III (simulated misfit), for both prosthetic designs. For each fabricated acrylic resin cast, the misfit and loosening torque analyses were assessed before and after mechanical loading (106 mechanical cycles, 2 Hz, 280 N). The initial prosthetic and mini abutment screws loosening torque were measured 24 hours after the tightening torque (10 Ncm and 20 Ncm, respectively) using a digital torque meter. The single-screw test was performed and the vertical misfit was quantified using an optical microscope. The strain after fixation was evaluated in a plaster cast using strain gauges analysis with each framework tightened to the cast with 10 Ncm standardized torque. The results were submitted to exploratory analysis followed by statistical tests such as ANOVA and Tukey (? = 0.05) when parametric data were found and Mann-Whitney and Wilcoxon when non-parametric data were obtained. For all groups, the cyclic loading had no significant difference when analyzed the prosthetic screw loosening torque, misfit and strain, but there was an increase of the mini abutment loosening torque mean values for FPD of groups II and III and for FFP of group III. The Pearson correlation test (? = 0.05) indicated a positive correlation between misfit and strain for all evaluated situations and a negative correlation between loosening torque and vertical misfit for both prostheses designs of groups II and III. Within the evaluated conditions and obtained results, it can be concluded that cyclic loading of screw-retained multiple prosthesis does not exert significant influence on loosening torque, misfit and strain. The prosthetic screws have a greater tendency to loosening in ill-fitting prosthesis, which induces higher strain values on prosthesis-implant system / Mestrado / Protese Dental / Mestra em Clínica Odontológica
|
128 |
Efeito da ciclagem mecânica e da técnica de fundição sobre o desajuste marginal, tensão e torque de afrouxamento de infraestruturas de próteses múltiplas implantossuportadas = Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prostheses / Effect of cyclic loading and casting technique over marginal fit, strain and loosening torque on frameworks of multi-unit implant-supported prosthesesBhering, Cláudia Lopes Brilhante, 1989- 21 June 2013 (has links)
Orientadores: Marcelo Ferraz Mesquita, Jessica Mie Ferreira Koyama Takahashi / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T08:00:41Z (GMT). No. of bitstreams: 1
Bhering_ClaudiaLopesBrilhante_M.pdf: 2599454 bytes, checksum: bd13164e8616791d20fc97e7001d9fc7 (MD5)
Previous issue date: 2013 / Resumo: Este estudo teve como objetivo avaliar a influência do processo de fundição e da ciclagem mecânica sobre o desajuste marginal, tensão e torque de afrouxamento de próteses múltiplas implantossuportadas. Infraestruturas de prótese parcial fixa (PPF) suportada por dois implantes e prótese total fixa (PTF) suportada por cinco implantes foram enceradas usando cilindros de mini pilar totalmente calcináveis ou sobrefundidos (n=10). A partir das infraestruturas enceradas, os modelos de trabalho foram confeccionados utilizando análogos de implante (Hexágono Externo - 4.1mm) parafusados a mini pilares e um índex de gesso foi confeccionado utilizando análogos modificados de mini pilar. Quatro grupos foram obtidos de acordo com o tipo de prótese (PPF ou PTF) e cilindro protético (calcinável ou sobrefundido) avaliado. As infraestruturas foram fundidas em liga de CoCr e os parafusos apertados com 20Ncm (mini pilar) e 10Ncm (protético) utilizando torquímetro digital. Após 24 horas, o torque de afrouxamento e o desajuste inicial foram avaliados. O desajuste foi aferido por meio do teste do parafuso único. A análise de tensão foi realizada por meio de strain gauges colados na superfície dos análogos modificados, formando ¼ de ponte de Wheatstone. Os parafusos foram reapertados e as amostras submetidas a 106 de ciclos mecânicos (2Hz/280N). As mensurações finais foram realizadas e os resultados submetidos à Anova - 2 fatores/Teste de Tukey HSD e correlação de Pearson (?=0,05). Não houve diferença no desajuste para todos os intervalos de tempo e grupos avaliados no índex de gesso (p>0,05). As infraestruturas sobrefundidas apresentaram maior tensão que as obtidas com cilindros calcináveis (PPF: Inicial p=0,0047; Final p=0,0004; PTF: Inicial p=0,0476; Final p=0,0115). Não houve influência da ciclagem mecânica na tensão (p>0,05). No modelo de trabalho, as PPFs confeccionadas com cilindros calcináveis apresentaram maior desajuste que as sobrefundidas (Inicial: p=0,0005; Final: p=0,0007). As PTFs apresentaram desajuste similar (p>0,05). A ciclagem mecânica não influenciou o desajuste em ambos os modelos avaliados (p>0,05). Os parafusos de mini pilar das PTFs sobrefundidas apresentaram menor torque de afrouxamento que o grupo calcinável após a ciclagem mecânica (p=0,0024). Os parafusos protéticos dos grupos calcináveis apresentaram menor torque de afrouxamento que os sobrefundidos no tempo final (PPF: p=0,0013; PTF: p=0,0064). O torque de afrouxamento dos parafusos protéticos das PPFs calcináveis diminuiu após a ciclagem mecânica (p=0,0044). Correlação negativa foi observada entre o desajuste e o torque de afrouxamento dos parafusos protéticos (PPF: r=-0,49523 p=0,0012; PTF: r=-0,31423 p=0,0483). Não houve correlação entre o desajuste e a tensão (PPF: r=0,24 p>0,05; PTF: r=0,21 p>0,05). Conclui-se que o benefício do cilindro utilizado em relação à adaptação depende do tipo de prótese e componente sobre o qual o desajuste é avaliado. Próteses confeccionadas com cilindros sobrefundidos geram maior tensão e apresentam maior estabilidade dos parafusos protéticos. A ciclagem mecânica não influencia o desajuste e a tensão de próteses múltiplas, mas reduz o torque de afrouxamento em infraestruturas com maior desadaptação. Não existe correlação entre desajuste vertical decorrente da fundição e a tensão. Contudo, há correlação entre o desajuste marginal e o torque de afrouxamento dos parafusos protéticos mediante a ação de forças dinâmicas / Abstract: This study aimed to evaluate the influence of casting and cyclic loading on marginal misfit, strain and loosening torque of multiple implant-supported prostheses. Fixed partial dentures (FPD) frameworks supported by two implants and fixed full-arch dentures (FAD) frameworks supported by five implants were waxed using overcasted or calcinable mini abutment cylinders (n=10). The models were obtained with external hexagon implant analogs and mini abutments fixed to waxed frameworks. A plaster index was obtained using mini abutment modified analogs for strain gauge analysis. Four groups were obtained according to prosthesis (FPD or FAD) and cylinder (calcinable or overcasted) type. The frameworks were casted in CoCr alloy. The abutment and prosthetic screws were tightened with 20Ncm and 10Ncm, respectively, using digital torque meter. After 24 hours, initial loosening torque and marginal misfit were evaluated. The misfit readings were performed following the single screw test protocol. The prosthetic screws were tightened with 10Ncm and strain analysis performed by strain gauges bonded at the mini abutment analogs surface forming a ¼ of Wheatstone bridge. The screws were retightened and the samples submitted to 106 mechanical cycles (2Hz/280N). The final measurements were performed and the results submitted to 2 way - Anova/Tukey's HSD Test and Pearson Correlation Test (?=0.05). No difference was found in marginal misfit on all time intervals and groups on the plaster index (p>0.05). The frameworks manufactured with overcasted cylinders presented higher strain than calcinables ones, regardless of prosthesis type and time evaluated (FPD: Initial p=0.0047; Final p=0.0004; FAD: Initial p=0.0476; Final p=0.0115). No difference was observed in strain before and after cyclic loading (p>0.05). Considering the resin model, the calcinable FPD groups presented higher marginal misfit than overcasted ones (Initial: p=0.0005; Final: p=0.0007). Similar marginal misfit was noted among FAD groups (p>0.05). The cyclic loading did not affect the marginal misfit (p>0.05) in both evaluated models. The overcasted FADs abutment screws showed lower loosening torque than calcinable ones after cyclic loading (p=0.0024). The prosthetic screws of calcinable frameworks presented lower loosening torque than the overcasted at final measurement (FPD: p=0.0013; FAD: p=0.0064). After cyclic loading, the prosthetic screw loosening torque of calcinable FPDs decreased (p=0.0044). Negative correlation was observed between marginal misfit and loosening torque of prosthetic screws (FPD: r=-0.49523 p=0.0012; FAD: r=-0.31423 p=0.0483). No correlation was observed between misfit and strain (FPD: r=0.24 p>0.05; FAD: r=0.21 p>0.05). It is concluded for marginal fit, the benefit of the cylinder type depends on prosthesis design and component evaluated. Overcasted components generate higher strain and screw stability than totally calcinable ones. The cyclic loading did not influence misfit and strain of multiple-unit prostheses, but decreased the screw loosening torque in poorly fitted frameworks. There was no correlation between marginal misfit resulted from casting and strain induced on the system. There was correlation between marginal misfit and prosthetic screw loosening torque when submitted to cyclic loading / Mestrado / Protese Dental / Mestra em Clínica Odontológica
|
129 |
The effect of platform connection and abutment material on stress distribution in single anterior implant-supported restoration = a 3D finite element analysis = A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes: um estudo pelo método dos elementos finitos / A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes : um estudo pelo método dos elementos finitosCarvalho, Marco Aurélio de, 1989- 23 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:33:02Z (GMT). No. of bitstreams: 1
Carvalho_MarcoAureliode_M.pdf: 8351585 bytes, checksum: 5577f7f5bed23cd367f52fac8602f7af (MD5)
Previous issue date: 2013 / Resumo: A reabilitação de elementos unitários com implantes osseointegrados na região anterior da maxila é um cenário desafiador diante dos requisitos estéticos e funcionais. Nesse contexto, diferentes tipos de conexões pilar/implante e materiais constituintes do pilar surgiram no intuito de suprir as exigências estético-funcionais atuais. A distribuição de tensão no sistema de restaurações cimentadas a pilares cerâmicos parafusados a implantes é um fator importante na elucidação do processo de falha e também na previsibilidade de sucesso do tratamento. O objetivo do trabalho foi avaliar o efeito de diferentes conexões e materiais de pilar na distribuição de tensões em restaurações sobre-implante unitárias anteriores através do método dos elementos finitos. Foram obtidos 9 grupos experimentais a partir da combinação de três conexões protéticas (hexagonal externa-HE, hexagonal interna-HI e cone morse-CM) e três tipos de material constituinte do pilar (titânio-Ti, zircônia-Zr e híbrido-H): HETi, HEZr, HEH, HITi, HIZr, HIH, CMTi, CMZr, CMH. Com o auxilio do software de modelagem 3D (SolidWorks 2012 Corp., Concord, MA, EUA), foram obtidos os modelos geométricos que se constituíam de: segmento anterior de maxila; implantes HE, HI e CM construídos a partir do implante Titamax Ex 4x13mm (Neodent, Curitiba, Brasil); pilar do tipo Munhão Anatômico CM (Neodent, Curitiba, Brasil) em titânio, zircônia e híbrido (corpo em zircônia e base em titânio) para implantes HE, HI e CM; coroa do elemento 21 em dissilicato de lítio cimentada com cimento resinoso. Foi aplicada uma carga, de 49N em 45 graus em relação ao longo eixo do dente, de forma contínua em 6 etapas desde a região de cíngulo à borda incisal, no intuito de simular o movimento de excursão da guia incisal. O critério de Tensão Equivalente de von Mises (?vM) foi utilizado para a avaliação quantitativa e qualitativa dos implantes e pilares entre os nove grupos. As tensões máxima (?max) e mínima (?min) principais foram utilizadas para a avaliação quantitativa entre os pilares de zircônia e corpo de zircônia de pilares híbridos. Os maiores valores de ?vM (MPa) para o pilar foram encontrados nos grupos CMZr, CMH e CMTi (315,61; 293,61; 289,36 respectivamente), e os menores nos grupos HEH, HITi e HIH (91,70; 97,58; 100,65, respectivamente). Os valores ?max e ?min foram menores nos grupos H que nos Zr. Qualitativamente, a concentração de tensão se deu na interface pilar/implante em todos os grupos, independente da conexão ou material do pilar. Concluiu-se que o tipo de conexão teve maior influência que o material constituinte nas tensões acumuladas nos pilares, sendo que os pilares híbridos tiveram comportamento mecânico semelhante aos de titânio, que por sua vez foi melhor que os pilares em zircônia / Abstract: The anterior single crown reconstruction is still a challenging scenario in implant dentistry. Within the esthetic and functional demand, different platform connections and abutment material emerged for better outcomes. The stress distribution through the structure is an important factor to be elucidated for better fail process understanding and also to the treatment success predictability. Therefore, the aim of this study was to evaluate the effect of different abutment material and platform connection on stress distribution in single anterior implantsupported restorations, through the finite element method. Nine experimental groups were design from the combination of three platform connection (external hexagon-EH, internal hexagon-IH and morse tapered-MT) and three abutment material (titanium-Ti, zirconia-Zr and hybrid-H): EHTi, EHZr, EHH, IHTi. IHZr, IHH, MTTi, MTZr, MTH. Finite element models were obtained with the aid of a modeling software (SolidWorks 2012 Corp., Concord, MA, USA), and consisted of: EH, IH and MT implants modeled from Titamax Ex 4x13mm (Neodent, Curitiba, Brazil); abutment modeled from Anatomic Abutment CM (Neodent, Curitiba, Brazil) in titanium, zirconia and hybrid (two-piece abutment); lithium disilicate central incisor crown cemented over the abutment. The occlusal loading, consisted of a magnitude of 49N in 45 degrees to the implant long axis, was applied in six steps in order to simulate the incisal guidance. The equivalent von Mises criterion (?vM) was used for both qualitative and quantitative evaluation of implant and abutment among all groups. The maximum (?max) and (?min) minimum principal stresses were obtained for numerical comparison of zirconia abutment and zirconia abutment body. The highest abutment ?vM (MPa) occurred in MTZr, MTH and MTTi (315.61; 293.61; 289.36 respectively); and the lowest in EHH, IHTi and IHH (91.70; 97.58; 100.65, respectively). The ?max and ?min values were lower in H groups than Zr groups. The stress distribution concentrated in the abutment/implant interface in all groups, regardless the platform connection or abutment material. It was concluded that the platform connection had more influence than abutment material on stress values and distribution on abutments, and the stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
130 |
Desenvolvimento de bionanocompósitos Poli(álcool vinílico)-Poliuretano/Hidroxiapatita para enxerto maxilo facial / Poly(vinyl alcohol)-Polyurethane/Hydroxyapatite bionanocomposites development for facial maxillo graftAndrade, Sabina da Memoria Cardoso de, 1955- 20 August 2018 (has links)
Orientadores: Cecília Amélia de Carvalho Zavaglia, Carmen Gilda Barroso Tavares Dias / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-20T18:23:16Z (GMT). No. of bitstreams: 1
Andrade_SabinadaMemoriaCardosode_D.pdf: 7127568 bytes, checksum: 0ebd83d085ffff7fe81cf8749ab309fb (MD5)
Previous issue date: 2012 / Resumo: A coesão de um grupo de profissionais de diversas áreas onde haverá troca de informações para a concretização de um biomaterial é fator decisivo para reunir todos os requisitos necessários de caracterizações físicas, químicas e biológicas e assim garantir biocompatibilidade e biofuncionalidade, associadas à interação entre o tecido vivo e o biomaterial. Scaffold biodegradável que combina a bioatividade de hidroxiapatita (HA) e a degradabilidade ajustável de matriz de poliuretano (PU) obtido a partir do PVAl foi desenvolvido nesta pesquisa e submetido à caracterizações morfológicas, mecânicas e biológicas. Este novo tipo de scaffold não é tóxico, apresenta interconexão de poros e microporos nas paredes dos poros, boa resistência mecânica e boa ativação de crescimento celular, propriedades que satisfazem as exigências do uso clínico. As análises através de microscopia eletrônica de varredura mostram além da conexão de poros as nanopartículas de hidroxiapatita distribuídas de maneira uniforme na matriz do bionanocompósito. Os valores médios de resistêcia à compressão da matriz e do bionanocompósito foram próximos de 60 MPa tanto para PVAl-PU como para PVAl-PU/HA com 25% de HA, e 105 MPa PVAl-PU/HA com 33% de HA. Após 24 horas de implante o biomaterial PVAl-PU/HA já apresentou em observação por MEV, detalhe de células aderidas, sugestivas provavelmente de células de fibroblasto, espraiamento com formação de uma camada celular compacta e homogênea e após 14 dias do implante foi observada a interação do biomaterial com as camadas do tecido subcutâneo e a invasão do crescimento celular pelos poros interconectados do scaffold. Portanto o scaffold desenvolvido neste trabalho é indicado com expectativas promissoras para implantes ósseos / Abstract: The cohesion of a group of professionals from many areas, exchanging information to concretize a bio material, is a crucial factor to gather all of the requirements of physical, chemical, and biological characterization and therefore ensure biocompatibility and bio functionality, associated to the interaction of the living tissue and the biomaterial. In this research it was developed and subjected to morphological, mechanical and biological characterization, a biodegradable scaffold that combines the bioactivity of hydroxyapatite (HA) and the adjustable degradability of polyurethane matrix (PU) obtained from the PVA1. This new kind of Scaffold is non toxic, has interconnected pores and micropores at the pore's wall, great mechanical resistance and great cellular growing activation. These properties meet the clinical use requirements. The scanning electronic microscopy analysis shows, beside the pore connection, the hydroxyapatite microparticles arranged evenly in the bionanocomposite. The medium values of compression resistance of the matrix and of the bionanocomposite were close to 60 MPa for PVA1-PU well as PVA1-PU/HA with 25% of HA, and 105 MPa PVA1-PUH/HA with 33% of HA. After 24 hours of insertion, the biomaterial PVA1-PU/HA presented as seen in MEV observation, adherent cells, probably coming from fibroblast cells, spreading with a cellular compact and homogeneous layer and, after 14 days of the insertion, it was observed the biomaterial interaction with the layers of the subcutaneous tissue and the invasion of the cellular growing through the scaffold's interconnected pores. Therefore, the osseous scaffold is indicated with promissing expectations to implants / Doutorado / Materiais e Processos de Fabricação / Doutora em Engenharia Mecânica
|
Page generated in 0.0507 seconds