• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 210
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 223
  • 136
  • 94
  • 86
  • 47
  • 36
  • 33
  • 29
  • 29
  • 27
  • 23
  • 23
  • 19
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Fatores subjetivos e comorbidades psiquiátricas influência na adesão à anticoagulação oral por pacientes reumáticos portadores de prótese cardíaca valvar mecânica

Silva, Regina Ponce da January 2011 (has links)
Made available in DSpace on 2014-12-22T16:37:26Z (GMT). No. of bitstreams: 2 regina_silva_ipec_mest_2011.pdf: 625070 bytes, checksum: 8900e532b2fe93a68034a0dd8aba65f7 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2014-10-07 / Fundação Oswaldo Cruz. Instituto de Pesquisa Clínica Evandro Chagas, Rio de Janeiro, RJ, Brasil / A febre reumática pode evoluir para cardiopatia reumática crônica e levar à necessidade de implante de prótese valvar mecânica seguido de anticoagulação oral obrigatória e permanente. A adesão do paciente ao tratamento é fundamental mas nem sempre ocorre adequadamente. Transtornos psiquiátricos podem interferir na adesão. Os objetivos do estudo foram: 1) identificar fatores subjetivos de influência na adesão à anticoagulação oral pelo paciente reumático portador de prótese valvar mecânica, segundo sua própria percepção; 2) conhecer a prevalência de transtornos psiquiátricos nessa população. Para alcançar o primeiro objetivo foi feita uma pesquisa qualitativa, fenomenológica, realizada através de entrevista semi-estruturada, na qual os pacientes falaram livremente sobre suas vivências com relação ao tratamento. Unidades de significado foram extraídas dos discursos e agrupadas em categorias de acordo com as convergências temáticas observadas. A partir do exame do material, observa-se que a anticoagulação oral é um tratamento de difícil seguimento, em que fatores relacionados principalmente ao modo de atuação da equipe e a aspectos cognitivos, comportamentais e emocionais do paciente mostram influência expressiva sobre a adesão à prescrição recebida Para atingir o segundo objetivo foi aplicado o teste Mini International Neuropsychiatric Interview (MINI), em 193 pacientes. Os resultados encontrados demonstram que os transtornos ansiosos e depressivos foram os mais prevalentes no grupo estudado, tendo sido observado elevado risco de suicídio. Não foi registrada diferença estatisticamente significativa entre a prevalência dos transtornos psiquiátricos nos grupos com e sem febre reumática / Rheumatic fever can develop into rheumatic heart disease and lead to the need to implant a mechanical valve prosthesis followed by mandatory and permanent oral anticoagulation. Adherence to treatment is essential but is not always achieved. Psychiatric disorders can interfere with adherence. The study objectives were : 1 ) identify subjective factors influencing the adherence on oral anticoagulation in patients with rheumatic mechanical valve prosthesis , according to his own perception , 2) find the prevalence of psychiatric disorders in this population. To achieve the first objective, we conducted phenomenological qualitative research, through semi - structured interviews, in which patients talked freely a bout their experiences in treatment. Signified units were extracted from speeches and grouped into categories according to thematic convergences observed. From the examination of the material, it is observed that oral anticoagulation treatment is difficult to follow. The health team performance and cognitive, emotional and behavioral aspects of patients show a significant influence on adherence to the prescription. To achieve the second objective, we conducted quantitative research, through structured in terviews by applying the test Neuropsychiatric Mini International Interview ( MINI) in 193 patients . The results show that depression and anxiety disorders were the most prevalent disorders in the group studied , and there was a high risk of suicide. There w as no statistically significant difference between the prevalence of psychiatric disorders in patients with and without rheumatic fever
42

Implante endoscópico no esôfago distal de polimetilmetacrilato para controle do refluxo gastrofágico : estudo experimental em modelo animal

Freitag, Carmen Perez de Freitas January 2003 (has links)
XIXA doença do refluxo gastroesofágico (DRGE) comumente afeta o esôfago e provavelmente é a condição mais prevalente no segmento alto do trato gastrointestinal, acometendo entre 5 e 45% da população ocidental. A terapêutica atual para essa doença além de medidas gerais e dietéticas, inclui tratamento farmacológico e/ou cirurgia. Ambos podem ser eficazes, mas apresentam elevado custo financeiro. O tratamento com fármacos pode apresentar baixa aderência medicamentosa e a cirurgia tem baixa, mas não desprezível, morbidade e mortalidade. Idealmente o tratamento da DRGE deveria ser eficaz, com baixo risco e com baixo custo. Objetivos: 1. Desenvolver um modelo experimental em suínos para o estudo do Refluxo Gastroesofágico através da Pressão e do Volume de Vazão Gástricos; 2. Avaliar a eficácia do implante endoscópico de PMMA ao nível do Esfíncter Esofágico Inferior (EEI) para aumentar a Pressão de Vazão Gástrica, o Volume de Vazão Gástrico e a Pressão Basal do EEI; 3. Descrever as reações histológicas associadas ao implante de PMMA. Material e Métodos: Suínos da raça Large White, do sexo feminino com 8 semanas de vida foram estudados no experimento. Foi realizada manometria do esfíncter esofágico inferior com registro da pressão basal com cateter de perfusão com água e técnica de retirada lenta. Calculou-se, também, a extensão do EEI. Após, gastrostomia era realizada com colocação intragástrica da extremidade distal de uma sonda de Foley com três vias e um cateter de pHmetria esofágica introduzido via oral com o sensor distal posicionado 5 cm acima do bordo superior de esfíncter esofágico inferior. Iniciava-se, XXentão, a infusão contínua no estômago de uma solução de HCl a 0,02N com medida e registro simultâneos da Pressão e do Volume de Vazão Gástricos e do pH esofágico. Definiu-se a Pressão de Vazão Gástrica (PVG) e o Volume de Vazão Gástrico quando houve brusca e sustentada acidificação do esôfago distal (pH<3). Após, introduzia-se um tubo metálico (Tubo Introdutor ou TI) via oral e, em seguida, o endoscópio, seguindo ambos até o esôfago distal. Cateter de nylon com agulha calibre 16 era introduzido pelo tubo introdutor e o PMMA implantado na área correspondente ao EEI com uma pistola dosadora volumétrica que permitia a injeção de volumes prédeterminados em 3 ou 4 pontos da submucosa (total por ponto = 0,73 ml de PMMA). As medidas de PVG, VVG e pressão basal do EEI foram repetidas após 28 dias, sacrificando-se os animais e removendo-se esôfago médio e distal, junção esofagogástrica, fundo e corpo gástricos para estudo histológico. Previamente ao experimento, três projetos pilotos foram desenvolvidos. O primeiro designado como “Projeto Piloto: Refluxo Gastroesofágico por pHmetria de 24H” (RGE 24H) buscou a via de acesso transnasal para registro de pHmetria por 24 horas. No segundo, designado “Projeto Piloto: Esofagostomia”, para confirmação de refluxo gastroesofágico espontâneo em suínos da raça Large White, utilizou-se anestesia com associação de tiletamina 125 mg e zolazepam 125 mg em combinação com um sedativo, a xilazina a 2% . A pHmetria foi mantida por 24 horas. Os dados descritos por Kadirkamanathan et al. não foram reproduzidos no nosso laboratório. Optou-se então pela realização de um terceiro projeto, “Projeto Piloto: Gastrostomia” para induzir refluxo gastroesofágico através de um modelo experimental e testar a reprodutibilidade da Pressão de Vazão Gástrica. Obteve-se sucesso. Resultados: Trinta e sete animais foram estudados em 60 intervenções no Laboratório de motilidade experimental. O projeto piloto “RGE:24h” foi abandonado após perda de 5 animais pela anestesia com halotano e, solucionada esta questão, a sistemática infecção do tecido celular subcutâneo nasal, dificultando a manutenção do cateter de phmetria em outros 5 animais. No “Projeto Piloto: Esofagostomia”, em cinco animais estudados (cada animal em duas ocasiões diferentes) não se reproduziram os achados de refluxo espontâneo. No terceiro projeto “Projeto Piloto: Gastrostomia” quatro animais foram estudados em dois momentos diferentes obtendo-se sucesso e reprodutibilidade XXIdos dados. Criado o modelo experimental, quatorze suínos foram submetidos ao experimento com implante endoscópico de PMMA com os seguintes resultados: A média dos pesos com 8 semanas de idade foi 14,98 ± 2,43 e 28 dias após o implante, 20,26 ± 3,68. O ganho ponderal foi considerado normal para a espécie. A Pressão de Vazão Gástrica média no dia 1 foi 8,08 mmHg e no dia 28, 10,69mmHg (Teste t de Student: t = 2,72 gl = 13 p = 0,017). Os Volumes de Vazão Gástricos médios foram: 392,86 ml para o dia 1 e 996,71 ml no dia 28 (teste t de Student: t = 11,66 gl = 13 p< 0,001). A Pressão Basal do EEI e o comprimento do esfíncter, não apresentaram diferenças estatisticamente significativas. PMMA foi identificado como depósitos de grandes vacúolos no tecido intersticial ao exame histológico da junção esofagogástrica associado a histiócitos, plasmócitos e presença de células gigantes tipo Langhans indicando reação tecidual de corpo estranho em todos os animais. Fibrose e macrófagos com vacúolos intracelulares estiveram presentes em menor freqüência. Conclusões: 1. O modelo experimental, em suínos, desenvolvido viabilizou o estudo do Refluxo Gastroesofágico através da Pressão de Vazão Gástrica e Volume de Vazão Gástrico; 2. O implante de PMMA, no presente estudo, aumentou a Pressão de Vazão e o Volume de Vazão Gástricos, mas não a Pressão Basal do EEI, nem tampouco aumentou o seu comprimento; 3. Depósito de PMMA implantado e evidência de processo inflamatório crônico e reação tecidual de corpo estranho foi encontrada no local do implante de PMMA. Macrófagos com vacúolos intracelulares e fibrose foram encontrados com menos freqüência. / XXIIIGastroesophageal Reflux Diseases (GERD) has the highest prevalence at the upper gastrointestinal tract and affects between 5 and 45%of the Western populations. Treatment includes diet, behaviors modifications and drugs or surgery. Both are efficient but have high financial costs. Treatment with drugs may not have high patient adherence and surgery presents low but still considerable morbidity and mortality. The ideal GERD treatment should be efficient with low cost. Objectives: 1. To develop an experimental model in swines to study GERD through the Gastric Yield Pressure (GYP) and Volume (GYV); 2. To estimate the efficacy of endoscopic implant of polymetilmetacrilate (PMMA) at the lower esophageal sphincter (LES) to raise the LES basal pressure, the GYP and the GYV; 3. Report the histological findings associated to PMMA implant. Material and Methods: Large White swine breed, females, 8 weeks old were studied under anesthesia. LES manometry with water perfusion catheter in “pull through” technique and LES basal pressure were obtained. Also, LES length was calculated. Immediately after, a percutaneous gastrostomy was performed and the distal end of a three way Foley catheter located in the stomach. A pHmetry catheter was, also, located by mouth with its distal sensor 5 cm above the LES. Continuous infusion of a HCl solution (0,02 N) into the stomach was started and measurement of intragastric pressure and volume as well as esophageal pHmetry obtained. GYP and GYV were defined when a brisk and sustained distal esophageal pH felt below 3. Following a metallic tube (Introduction Tube or IT) was introduced by mouth and after, the endoscope was introduced, and both reach the distal esophagus. A large catheter nylon with needle (16G) was advanced through the IT and PMMA implanted in the submucosa corresponding to the LES, with dosing pistol that delivered fixed volume at 3 or 4 sites (0,73 ml at each site). A new gastrostomy, GYP, GYV and Basal LES were obtained 28 days after. The animals were sacrificed and their esophagi and stomachs removed and studied by microscopic. Previously to the experiment, three pilot projects were developed. The first, called “Pilot Project: Gastroesophageal Reflux by 24H pHmetry” registered esophageal 24 h phmetry transnasally. The second, called “Pilot Project: Esophagostomy” used IM/IV anesthesia with tiletamine 125mg and zolazepam 125mg associated to the sedative xylazine 2% and registering a 24H pHmetry to reproduce spontaneous gastroesophageal reflux at our laboratory as described (Kadirkamanathan et al.) but we did not reach success. Therefore, a third project called “Pilot Project: Gastrostomy” was launched to develop an experimental model to study gastroesophageal reflux through a percutaneous gastrostomy and measurement of GYP but short duration of esophageal pHmetry by mouth. Success and reproducibility of findings was reached Results: Thirty seven animals were studied by sixty interventions at the Experimental Motility Laboratory. The Pilot Project “GERD:24H” was given up after death of five animals during the anesthesia and infection of subcutaneous cellular tissues nasal in other 5 animals. The “Project Pilot: Esophagostomy” in five animals (Two studies per animal in two different occasion) did not reproduce spontaneous reflux findings published previously. At the third project “Pilot Project: Gastrostomy”, four animals were studied at two different days each and induction of reflux with reproducibility of findings. Once the experimental model was attained fourteen swines were submitted to the experiment with PMMA endoscopic implant and the following results: Mean body weight = 14,98 Kg ± 2,43 ( day 1or, before implant) and 20,26 ± 3,68 Kg (day 28 , after implant). The mean GYP was 8,08 mmHg (day 1) and 10,69 mmHg (day 28)with p = 0,017 by Student’s t test with t = 2,72 and d.f. = 13. The mean GYV was 392,86 ml (day 1) and 996,71 ml (day 28) with p < 0,001 by Student’s t test with t = 11,66 and d.f.=13. The LES basal pressure and length did not present statistic difference between day 1 and 28. XXVPMMA was identified at the microscopic examination of the gastroesophageal junction with presence of histiocyties, plasma cells associated to Langhans giant cells (suggesting foreign body reaction) in all animals. Fibrosis and macrophages with intracellular implant vacuoles had lower frequencies. Conclusions: 1. The experimental model developed permitted the GERD study trough GYP, GYV and LES basal pressure; 2. PMMA implant, at the present study, raised the GYP and GYV but neither the LES Basal Pressure nor its length; 3. PMMA deposits were identified in the interstitial space and chronic inflammation with foreign reaction was founding in all animals. Fibrosis and macrophages with intracellular implant vacuoles had lower frequencies.
43

Automatic human movement assessment with switching linear dynamic system : motion segmentation and motor performance

Baptista, Roberto de Souza 07 November 2016 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2016. / Submitted by Camila Duarte (camiladias@bce.unb.br) on 2017-01-23T13:54:52Z No. of bitstreams: 1 2016_RobertodeSouzaBaptista.pdf: 4876693 bytes, checksum: 85fa8f167eb908e08b5bf946b03e66bd (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-03-22T16:56:57Z (GMT) No. of bitstreams: 1 2016_RobertodeSouzaBaptista.pdf: 4876693 bytes, checksum: 85fa8f167eb908e08b5bf946b03e66bd (MD5) / Made available in DSpace on 2017-03-22T16:56:57Z (GMT). No. of bitstreams: 1 2016_RobertodeSouzaBaptista.pdf: 4876693 bytes, checksum: 85fa8f167eb908e08b5bf946b03e66bd (MD5) / Desenvolvimentos recentes na tecnologia de sensores portáteis estão trazendo dispositivos de medição de movimento humano para atividades cotidianas. Esses sensores fornecem aos usuários finais e profissionais de biomecânica uma quantidade de dados sem precedentes. Além disso, eles proporcionam o desenvolvimento de novas tecnologias em próteses inteligentes e sistemas de interação homem-máquina. No entanto, há uma falta de técnicas para extrair automaticamente as medições indiretas - tais como duração do movimento, amplitude ou coordenação motora - a partir desses dados. Medidas indiretas são necessárias para o reconhecimento, avaliação e análise do movimento humano, e são geralmente extraídas manualmente por meio de inspeção visual por um profissional de biomecânica. Esta tese propõe um novo método para a avaliação automática de movimentos humanos que executa segmentação e extração de parâmetros de desempenho motor (isto é, medições indiretas) em séries temporais de medições de uma seqüência de movimentos humanos. Utilizamos os elementos de um modelo de Sistema Dinâmico Linear Chaveado como blocos de construção para traduzir definições e procedimentos formais da análise tradicional do movimento humano. Nossa abordagem fornece um método para os usuários sem experiência em processamento de sinal para criar modelos para movimentos usando conjunto de dados rotulado e mais tarde empregá-lo para a avaliação automática. Validamos nossa estrutura de testes preliminares envolvendo seis sujeitos adultos saudáveis que executaram movimentos comuns em testes funcionais e sessões de exercícios de reabilitação, como sentar-e-levantar e elevação lateral dos braços, e cinco sujeitos idosos, dois com mobilidade limitada, que executaram o movimento de levantar-se da posição sentada. O método proposto foi aplicado em sequências de movimento aleatório para o duplo propósito de segmentação de movimento (precisão de 72-100%) e avaliação de desempenho motor (erro médio de 0-12%). / Recent developments in portable sensor technology are bringing human movement measurement devices to everyday activities. These sensors provide end users and biomechanists with unprecedented amount of data. Besides, they allow novel technologies in intelligent prosthesis and human-machine interaction systems to emerge. However, there is a lack of techniques to automatically extract indirect measurements - such as movement duration, amplitude or motor coordination - from these data. Indirect measures are necessary for recognition, assessment and analysis of human movement, and are usually extracted manually through visual inspection by a biomechanist. This thesis proposes a novel framework for automatic human movement assessment that executes segmentation and motor performance parameter extraction (i.e. indirect measurements) in time-series of measurements from a sequence of human movements. We use the elements of a Switching Linear Dynamic System model as building blocks to translate formal definitions and procedures from traditional human movement analysis. Our approach provides a method for users with no expertise in signal processing to create models for movements using labeled dataset and later employ it for automatic assessment. We validated our framework on preliminary tests involving six healthy adult subjects that executed common movements in functional tests and rehabilitation exercise sessions, such as sit-to-stand and lateral elevation of the arms, and five elderly subjects, two of which with limited mobility, that executed the sit- to-stand movement. The proposed method worked on random motion sequences for the dual purpose of movement segmentation (accuracy of 72-100%) and motor performance assessment (mean error of 0- 12%).
44

Qualidade de vida de pacientes com defeito do pavilhão auricular, reabilitados e em processo de reabilitação : avaliação da resistência à tração e torque dos parafusos dos implantes dos sistemas de retenção para próteses auriculares implantorretidas em função de ciclagem mecânica / Life quality of patients with auricular defects, rehabilitated and in phase of rehabilitation with implant-retained auricular prostheses and evaluation of tensile strength and torque of the screws of the attachment systems to retained-implant auricular prosthesis, in function of mechanical cycles

Santos, Mateus Veppo dos 09 July 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2015-11-20T19:12:11Z No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-12T20:32:38Z (GMT) No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / Made available in DSpace on 2016-05-12T20:32:38Z (GMT). No. of bitstreams: 1 2015_MateusVeppodosSantos.pdf: 1223994 bytes, checksum: 9e81488339c90d29af20465bbda9fb4c (MD5) / No presente estudo, foi realizada a análise da qualidade de vida de pacientes com defeito do pavilhão auricular, reabilitados e em processo de reabilitação por próteses auriculares implantorretidas, e a avaliação mecânica dos sistemas de retenção para próteses auriculares implantorretidas, em função de ciclagem mecânica. Para o primeiro estudo, 18 pacientes, de ambos os sexos e maiores de 12 anos de idade, responderam aos questionários WHOQOL-bref e de auto-avaliação, que visa avaliar diversas facetas relacionadas à qualidade de vida. Os dados obtidos foram tabulados e submetidos à análise estatística descritiva. Para o segundo estudo, foram confeccionados corpos de prova para avaliar a resistência à tração dos sistemas de retenção barra-clipe, O’ring, associação dos mesmos, e magnetos. As amostras foram submetidas a 1080 ciclos mecânicos de inserção e remoção, com registro da força de resistência à tração e torque dos parafusos, em 0 e 1080 ciclos. Os resultados obtidos, a partir dos questionários, demonstraram que a percepção da qualidade de vida pelos pacientes, em todos os aspectos analisados, foi considerada boa, independente da reabilitação ter sido concluída. Como resultado da retenção e torque, observamos que a associação dos sistemas barra-clipe e o’ring proporcionou maior retenção do que os demais; que houve diminuição da força de resistência à tração e torque dos parafusos após a ciclagem, independente do sistema. Concluímos que, apesar dos seus defeitos faciais, os pacientes mantém boa qualidade de vida e que os reabilitados por próteses devem fazer consultas de retorno, tanto para troca das próteses como para controle do torque dos parafusos e dos sistemas de retenção, devido ao uso diário da prótese. _______________________________________________________________________________________________ ABSTRACT / In the present study, was analyzed the quality of life in patients with auricular defects, rehabilitated and in phase of rehabilitation with implant-retained auricular prostheses, and also the retention strength and torque of the screws of the implants attachment systems for implant-retained auricular prostheses were evaluated mechanical cycling function. For the first study a total of eighteen patients of both genders and over the age of twelve answered the WHOQOL-Bref and self-evaluation, questionnaires used to assess different aspects related to quality of life. Data were tabulated and subjected to descriptive statistical analysis. In the second study, templates were done to evaluate Bar-clip, O’ring, bar-clip and o’ring associated, and magnets systems. The templates were submitted to 1080 mechanical cycles and were evaluated the force of traction and screw torque for each system in two stages: initial and after 1080 mechanical cycles. The results from the questionnaires showed that the patients quality of life perception, in all aspects evaluated, were considered good. The results about traction and screw torque showed that bar-clip and o’ring associated systems provides greater retention than the others attachment systems; there was a decreased resistance force to traction and torque of the screws after cycling, regardless of the system. We conclude that despite its auricular defects, patients maintain a good quality of life and those rehabilitated should make regular follow-ups, because of the a loss of torque of the screws of the implants and loss of retentive capacity of the attachment systems caused by the daily use of the prosthesis.
45

Avaliação de próteses mamárias quanto às características macroscópicas e resistência à tração.

FONSECA, Letícia Seixas Prata da. 09 July 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-07-09T15:49:08Z No. of bitstreams: 1 LETÍCIA SEIXAS PRATA DA FONSECA - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 1243293 bytes, checksum: 891b96b492cd9c5893bfc592ad82f05e (MD5) / Made available in DSpace on 2018-07-09T15:49:08Z (GMT). No. of bitstreams: 1 LETÍCIA SEIXAS PRATA DA FONSECA - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 1243293 bytes, checksum: 891b96b492cd9c5893bfc592ad82f05e (MD5) Previous issue date: 2015-02-06 / Após alerta sanitário emitido pela Agencia Francesa de Segurança Sanitária de Produtos de Saúde (AFFSAPS) de não conformidades no silicone utilizado para fabricação de próteses mamárias da empresa Poly Implant Prothese (PIP), a Agência Nacional de Vigilância Sanitária (ANVISA) publicou regulamentação estabelecendo a necessidade de certificação no âmbito do Sistema Brasileiro de Avaliação da Conformidade (SBAC) segundo parâmetros de Portaria do Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO) para avaliação de conformidade para Implantes Mamários. Dentre outros requisitos foi estabelecida a obrigatoriedade de observação das condições descritas na referida portaria. Neste trabalho foram avaliadas amostras de próteses mamárias de silicone de um mesmo fabricante, com as mesmas especificações, variando apenas o número dos lotes. Observaram-se as características macroscópicas das amostras como variáveis para a realização de ensaios normatizados. Foram comparadas características das amostras como rugosidade, cor, consistência, deformação, aderência ao elastômero, adesividade do gel e comportamento mecânico das membranas quando submetidas ao ensaio de tração. Embora tenham sido avaliadas próteses com as mesmas especificações de fabrica, foram observadas diferenças nas características macroscópicas das amostras e na resistência à tração. Quando avaliados em conjunto, os dados demonstram discrepâncias nas características das amostras e inconformidades com as normas estabelecidas. / After health alert issued by the French Agency for Sanitary Safety of Health Products (AFFSAPS) of non-compliance in the silicone used for the manufacture of breast implants the company Poly Implant Prothese (PIP), the Brazilian Health Surveillance Agency (ANVISA) has published regulations establishing certification requirement under the Brazilian System of Conformity Assessment (SBAC) within the parameters of Ordinance of the National Institute of Metrology, Quality and Technology (Inmetro) for conformity assessment to Breast Implants. Among other requirements the obligation to observe the conditions described in the said ordinance was established. In this work we were evaluated samples of silicone breast implants from the same manufacturer with the same specifications, varying only the number of lots. Were observed in the macroscopic characteristics of the samples as variable for performing standardized tests. Sample characteristics were compared as roughness, color, consistency, deformation, adhesion to the elastomer, gel adhesive and mechanical behavior of the membrane when subjected to tensile test. Although dentures have been evaluated with the same specifications of manufactures, differences were observed in macroscopic characteristics of the samples and tensile strength. When evaluated together, the data show differences in the characteristics of samples and noncompliance with established standards.
46

Avaliação das propriedades física, química e biológicas de próteses mamárias de silicone explantadas.

SERAFIM FILHO, Péricles Vitório. 10 July 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-07-10T12:32:58Z No. of bitstreams: 1 PÉRICLES VITÓRIO SERAFIM FILHO - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 2732272 bytes, checksum: f9246e9f76ba0abd4b6bbc275b9d09c4 (MD5) / Made available in DSpace on 2018-07-10T12:32:58Z (GMT). No. of bitstreams: 1 PÉRICLES VITÓRIO SERAFIM FILHO - DISSERTAÇÃO (PPGCEMat) 2015.pdf: 2732272 bytes, checksum: f9246e9f76ba0abd4b6bbc275b9d09c4 (MD5) Previous issue date: 2015-08-31 / Os implantes mamários caracterizam-se como dispositivos médicos que são usados para aumentar o tamanho dos seios ou para reconstruir a mama após mastectomia ou corrigir uma anomalia congênita. Sabe-se que desvio no processo produtivo de implantes mamários e o tempo de uso podem reduzir as propriedades do produto final e favorecer risco de agravos à saúde da população. Desta forma, este trabalho objetivou avaliar as propriedades físicas, químicas, biológicas e mecânicas de próteses mamárias de silicone explantadas. Os parâmetros de avaliação basearam-se na norma NBR 14 760 – 2001. Foram analisadas nove amostras de próteses mamárias de silicone texturizadas, com diferentes tempos de uso e os ensaios foram realizados em triplicata. Os ensaios de caracterização utilizados foram Microscopia Óptica - MO, Espectroscopia na Região do Infravermelho com Transformada de Fourier (FTIR), Coesividade do Gel, Ensaio Mecânico (Resistência a Tração) e Citotoxicidade. No ensaio de MO verificou-se padrões diversos de texturizações para as próteses, mas não foram observadas alterações significativas que comprometesse a qualidade das próteses mamárias, bem como nos espectros de FTIR. Baseado nos resultado obtidos no ensaio de coesividade do gel pode-se afirmar que apenas a amostra C não se encontra em conformidade com a norma International Standard ISO 14607. Nos resultados do Ensaio Mecânico, as amostras A, B, F, G e H encontraram-se em não conformidade com a norma. Os testes de citotoxicidade mostraram que as próteses analisadas estão em conformidade com a norma. Desta forma conclui-se que as amostras A, B, C, F, G e H estão fora dos parâmetros exigidos pelas normas vigentes e que o tempo de uso destas pode ter influenciado nestes resultados, sugerindo-se a continuidade de estudos considerando essa variável. / Breast implants are characterized as medical devices that are used to increase the size of breasts or to reconstruct the breast after mastectomy or to correct a congenital anomaly. It is known that deviations in the production process of breast implants and the use of time can reduce the properties of the final product and favor risk of harm to health. Thus, this study aimed to evaluate the physical, chemical, biological and mechanical properties of silicone breast implants explanted. The evaluation criteria were based on NBR 14 760 - 2001 were analyzed nine samples of textured silicone breast implants with different operating times and the assays were performed in triplicate. Characterization tests used were Microscopy Optica - MO, Infrared Spectroscopy in the Region Fourier Transform (FTIR), cohesiveness gel, Mechanical Test (Tensile Strength) and cytotoxicity. In the MO of study there are several standards for texturing the prosthesis, but no significant changes were observed that could compromise the quality of breast implants, as well as in FTIR spectra. Based on the results obtained in the gel assay cohesiveness, it can be stated that only sample C is not in accordance with International Standard ISO 14607.Nos results of mechanical testing, samples A, B, F, G and H found in noncompliance with the standard. Cytotoxicity tests showed that the prostheses are analyzed in accordance with the standard. Thus it is concluded that the samples A, B, C, F, G and H are out of the parameters required by current standards and that the time of use these may have influenced these results, suggesting continuing studies considering this variable .
47

Custos de órteses, próteses e materiais especiais não contemplados no Sistema Único de Saúde (SUS) em hospital de ensino brasileiro / Costs of orthoses, prostheses and special materials not contemplated in the Unified Health System (SUS) in a Brazilian teaching

Camargo, Telma Aparecida de [UNESP] 07 February 2017 (has links)
Submitted by TELMA APARECIDA DE CAMARGO null (tcamargo@fmb.unesp.br) on 2017-04-12T17:28:46Z No. of bitstreams: 1 versão fnal para repositorio.pdf: 2377085 bytes, checksum: c8d2c404964401f82652833da36e1d8f (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-04-17T20:46:42Z (GMT) No. of bitstreams: 1 camargo_ta_me_bot.pdf: 2377085 bytes, checksum: c8d2c404964401f82652833da36e1d8f (MD5) / Made available in DSpace on 2017-04-17T20:46:42Z (GMT). No. of bitstreams: 1 camargo_ta_me_bot.pdf: 2377085 bytes, checksum: c8d2c404964401f82652833da36e1d8f (MD5) Previous issue date: 2017-02-07 / Introdução: O uso de órteses, próteses e materiais especiais (OPME) está diretamente relacionado à evolução dos procedimentos cirúrgicos, sendo que as especialidades de ortopedia e cardiologia foram as primeiras a fazer uso dessa tecnologia. Hoje a medicina dispõe de OPME complexos, principalmente nas cirurgias endovasculares. Com a evolução tecnológica dos dispositivos médicos, acompanhada ao ganho na prestação de assistência médica, encontra-se a preocupação com a insuficiência de recursos no setor público, que adota o recurso da avaliação econômica para tomada de decisões. É evidente que nos hospitais de ensino a necessidade de investimento em tecnologia é maior do que nas demais instituições devido à complexidade dos atendimentos, a presença de médicos especialistas e atividades de ensino. Ademais, os lançamentos de dispositivos médicos geralmente não são remunerados pela tabela do Sistema Único de Saúde (SUS), sendo importante a avaliação de tecnologias em saúde (ATS) para incorporação de nova tecnologia por meio da Comissão Nacional de Incorporação de Tecnologias (CONITEC). Objetivo. Analisar os custos dos dispositivos de OPME exclusivamente relacionados ao ato cirúrgico, não incluídos na tabela SIGTAP. Método: Trata-se de um estudo descritivo retrospectivo, com análise quantitativa dos dados de uso de dispositivos não incluídos na tabela SUS de um Hospital Público Universitário, localizado no interior do Estado de São Paulo e vinculado à Secretaria de Estado da Saúde de São Paulo. Resultados: Foram identificados 11 dispositivos médicos não incluídos na tabela SUS, cujo valor unitário de aquisição variou entre R$ 178,00 e R$ 17.460,00, correspondendo a 146 (3%) do total de internações com uso de OPME. O custo total da internação/procedimento, incluindo a OPME que não consta na Tabela SUS, foi superior ao ressarcimento pelo SUS na maioria dos dispositivos estudados. Conclusão: O estudo possibilitou o mapeamento dos dispositivos utilizados nas instituições hospitalares, não ressarcidos pelo SUS, e foram identificados os custos elevados com as internações e/ou procedimentos envolvendo as OPME. Evidenciou ainda a necessidade de estudos de Avaliação de Tecnologias em Saúde dos dispositivos para tomada de decisão dos gestores. Produto: Foi elaborado parecer técnico-científico (avaliação de tecnologias em saúde) do dispositivo Kit de artroscopia de ombro para contribuir com a tomada de decisão do gestor da instituição local. / Introduction: The use of orthoses, prostheses and special materials (OPME) is directly related to the evolution of surgical procedures and orthoprdic and cardiology specialties were the first to make use of this technology. Nowadays, with the technological evolution of the medical devices, the OPME are more complex especially in endovascular surgeries. These improvements were accompanied by a better heath care quality; however, there is a concern about the limited resources of the public sector. Therefore, the use of economic evaluation for the decision-making in the area of OPME is fundamental. Teaching hospitals needs more investments in technology than other institutions due to the complexity of the procedures, the presence of medical experts and students of various degrees in addition, there is a gap between the launch of a new OPME device and the incorporation of this technology by public health system in Brasil (Sistema Único de Saúde – SUS). Therefore, is important a cost- benefit assessment of the new health technologies (ATS) in OPME before the incorporation by the National Commission for the Technologies Incorporation. . Objective: Map the devices of OPME, not included in the SUS table, limited to those related to the surgical act and calculate their costs. Method: This is a retrospective descriptive study, with quantitative analysis the data concerning the use of OPME devices not included in the SUS table of a Public University Hospital, located in the interior of the State of São Paulo and linked to the State Department of Health of São Paulo. Results: Were identified 11 medical devices not included in the SUS table, whit unit value of acquisition varied between R$ 178.00 to R $ 17.460,00, corresponding to 146 (3%) of the total admissions using OPME. The total cost of the hospitalization / procedure, including OPME not incorporated in the SUS table, was higher than the reimbursement for almost all the devices studied. Conclusion: The study shows that is possible to map the devices not reimbursed by the public health system, and identified the high costs of hospitalizations and / or procedures involving OPME. It also evidenced the need for studies of Health Technology Assessment to help decision-making of the hospital managers. Product: It was elaborated the technical-scientific opinion (health technology assessment) from the device Kit of the shoulder arthroscopy to contribute with the decision-making of the manager of the local institution.
48

Desenvolvimento, comportamento mecânico e microestrutural de uma prótese mandibular em liga de titânio produzida por sinterização direta a laser de metal (DMLS) /

Gregolin, Rafael Ferreira. January 2013 (has links)
Orientador: Ruis Camargo Tokimatsu / Banca: João Antonio Pereira / Banca: Cecilia Amelia de Carvalho Zavaglia / Resumo: A prototipagem rápida está sendo utilizada em diversas áreas do conhecimento humano para auxiliar no estudo e muitas vezes na própria fabricação do componente usual. Atualmente, com o avanço de softwares, pode-se criar com facilidade imagens tridimensionais, ou mesmo, capturar essas imagens de equipamentos como a tomografia computadorizada e a ressonância magnética. Consegue-se reproduzir qualquer parte do corpo humano com grande perfeição e isso é utilizado na fabricação de implantes, scaffolds (arcabouços - engenharia de tecidos), materiais de auxílio e preparação em cirurgias (biomodelos). Os principais materiais utilizados na fabricação de implantes hoje são: o titânio puro, as ligas de titânio, o aço inoxidável, o polietileno, o PMMA, as ligas de cobalto-cromo e as cerâmicas. Este trabalho se propõe a fazer: um estudo mecânico e microestrutural da liga Ti-6Al-4V obtida por prototipagem rápida no processo de sinterização direta a laser de metais (DMLS) e compará-la com a liga Ti-6Al-4V produzida por processos convencionais de conformação (trefilação). Além disso, pretende realizar o desenvolvimento de uma placa condilar personalizada utilizada para patologias de distúrbios de ATM (articulação têmporo-mandibular), avaliando sua geometria pelo software ANSYS®, com o apoio da tomografia computadoriza e do software de construção de imagens tridimensionais INVESALIUS® / Abstract: Rapid prototyping is being used in various areas of human knowledge to assist in the study and often in the usual component manufacturing. Today, with the advancement of software, you can easily create three-dimensional images, or even, capture these images of equipment such as computed tomography and magnetic resonance imaging. You able to reproduce any part of the human body with great perfection and it's used in the manufacture of implants, scaffolds (tissue engineering), material aid and preparation for surgery (biomodels). The main materials used in the manufacture of implants today are: pure titanium, titanium alloys, stainless steel, polyethylene, PMMA, the cobalt-chromium alloys and ceramics. This paper proposes to do: mechanical and microstructural studies of alloy Ti-6Al-4V obtained by rapid prototyping process in direct metal laser sintering (DMLS) and compare it with the Ti-6Al-4V alloy produced by conventional forming process (wiredrawing). Also, make the development of a custom condylar plate used for diseases of TMJ (temporomandibular joint) disorders, assessing its geometry by ANSYS® software with the help of computerized tomography and the software to build three-dimensional images INVESALIUS® / Mestre
49

Análise extensométrica de cargas estáticas axiais e não axiais em próteses implantossuportadas de três elementos /

Paulo, Gabriel Portela. January 2011 (has links)
Orientador: Renato S. Nishioka / Banca: Alexandre Luiz Souto Borges / Banca: Gelson Luis Adabo / Resumo: A proposta desde estudo foi avaliar, in vitro, por meio da extensometria, a influência da aplicação de cargas axiais e não axiais em próteses parciais fixas de três elementos, suportadas por implantes. Para isso, foram inseridos na configuração linear, em um bloco de poliuretano, três implantes com hexágono externo. Quatro extensômetros foram colados linearmente na superfície do bloco, tangentes aos implantes e perpendiculares ao seu longo eixo, com o intuito de mensurar a microdeformação perimplantar no momento da aplicação de cargas. Pilares protéticos microunit foram conectados aos implantes com torque de 20 Ncm. Sobre os pilares foram parafusados padrões fundidos em liga de Co-Cr (n=5) com torque de 10 Ncm que receberam os carregamentos. Foram aplicados 30 Kg, durante 10 segundos, em 9 pontos pré-determinados e os dados registrados com auxilio de um condicionador de sinais elétricos e do software Strain-Smart. Os resultados obtidos foram submetidos à Análise de Variância (ANOVA) e ao teste de comparação múltipla de Tukey (5%). Os resultados não mostraram diferença estatisticamente significante para os pontos de aplicação de carga, sendo que a média de deformação foi sempre similar quando a carga foi aplicada axialmente e nos pontos não axiais. Concluiu-se por esta metodologia que o aumento da largura da sobrestrutura mediante este tipo de carregamento não alterou a deformação da área estudada / Abstract: The aim of this study was to evaluate quantitatively, in vitro, using strain gages the influence of axial e non axial loading, over a structure simulating implant-supported fixed partial denture, around three implants linearly positioned. In a polyurethane block were linearly positioned three external hexagon implants and four strain gages, following the line were positioned over de block surface perpendicularly to the implants, in order to gauge the micro strain around the implants under load. Micro Unit abutments (20 Ncm torqued) supported the supra structures, Co-Cr alloy (n=5) bolted with a 10 Ncm torque, during the loading tests. One at a time, the load of 30kg were applied in nine pre determined points over the structure and the data collected with the aid of an electrical signal conditioner and the software Strain Smart. The data were submitted to variance analysis (ANOVA) and multiple Tukey test 5%. There were not found significant differences between the place of load application and the gauge mean in the different strain gages. It was possible to evaluate that the strains around implants tested in this study were above the physiological bone limit / Mestre
50

Método de concepção de articulações flexíveis em impressoras 3D / Design method for flexible joints build in 3D printers

Silva, Jorge Ribeiro Cunha da 31 July 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade Gama, Programa de Pós-Graduação em Engenharia Biomédica, 2014. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2014-10-08T16:01:57Z No. of bitstreams: 1 2014_JorgeRibeiroCunhaSilva.pdf: 4492776 bytes, checksum: d71866642f3496ddb73e5751fa061f50 (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-14T19:50:43Z (GMT) No. of bitstreams: 1 2014_JorgeRibeiroCunhaSilva.pdf: 4492776 bytes, checksum: d71866642f3496ddb73e5751fa061f50 (MD5) / Made available in DSpace on 2014-10-14T19:50:43Z (GMT). No. of bitstreams: 1 2014_JorgeRibeiroCunhaSilva.pdf: 4492776 bytes, checksum: d71866642f3496ddb73e5751fa061f50 (MD5) / Em todo o mundo mais de um bilhão de pessoas convivem com alguma deficiência, muitos necessitam do uso de prótese para suprir a ausência de um membro funcional. Na busca pela utilização de novas tecnologias a prototipagem rápida se apresenta como uma solução viável, pois o fator econômico é fundamental. A partir de um modelo de prótese de mão, disponibilizado na internet, é proposta a construção de um novo modelo, utilizando uma metodologia de impressão em 3D com a utilização de dois plásticos. A avaliação dos materiais se faz necessária para segurança do produto e para isto foram feitos dois ensaios mecânicos, sendo o primeiro um ensaio de fadiga em corpos de prova normatizados, realizado para avaliar as propriedades apenas do produto elástico de dois fornecedores, um nacional e outro importado, pois o plástico rígido não será exposto a carregamento significativo no produto em questão. Como resultado, verificou-se que tanto o nacional quanto o importado atendem as necessidades de carga a que serão submetidos, sendo que de forma descritiva, os corpos nacionais apresentaram uma carga média maior quando comparados ao importado, para o mesmo estiramento. Da mesma forma, os corpos nacionais apresentaram uma queda de carga media menor quando comparados ao importado, para o mesmo estiramento. Um segundo ensaio é proposto para teste em um modelo de dedo impresso, ajustado ao formato de um corpo de prova padronizado, sendo para isso construída uma máquina de ensaio mecânico, adaptada para as condições básicas do funcionamento do dedo, utilizando-se dos valores de referencia para próteses. Neste segundo ensaio, os resultados apresentados para os limites de utilização estabelecidos foram satisfatórios. Verificou-se conclusivamente que, analisando-se o conjunto de ensaios realizados nos corpos de prova e nos dedos impressos, as articulações construídas atendem as necessidades básicas, para a utilização desta tecnologia com segurança para possíveis aplicações em próteses e órteses. ___________________________________________________________________________ ABSTRACT / Worldwide over one billion people live with some kind of disability; many of them require the use of prosthesis to compensate the absence of a functional limb. By seeking the use of new technologies to meet this demand, the rapid prototyping with 3D printer, is presented as a viable solution, since the economic factor is critical. The building of a new prosthesis model is proposed based on a template available on the Internet, using a printing 3D methodology with two types of plastic. A review of the materials becomes necessary for the safety of the product and for this two mechanical tests were made. The first being a fatigue test in standardized specimens, conducted to assess only the elastic materials properties of products of two suppliers, one national and the other imported, because the hard plastic will not be exposed to significant load on the product in question. As a result, it was found that both the national and imported meet the needs of the load that will be submitted, and descriptively, national specimens had a higher average load when compared to the imported ones for the same stretch. Similarly, national specimens fell by less average load when compared to the imported for the same stretch. A second test is proposed to test a model of finger printed, adjusted to the standardized specimen format, a machine of mechanical test was built for this, adapted to the basic conditions for the functioning of the finger, using the reference values for prostheses. In this second test, the results for the preset use limits were satisfactory. It was observed conclusively that, by analyzing the set of trials in the specimens and in printed fingers, constructed joints meet the basic needs for the use of this technology safely for possible applications in prosthetics and orthotics.

Page generated in 0.0299 seconds