Spelling suggestions: "subject:"produtos dde degradação"" "subject:"produtos dee degradação""
21 |
Desenvolvimento de metodologias indicativas de estabilidade para medicamentos que atuam no diabetes mellitus tipo II / Development of stability indicating methods for drugs that are used in diabetes mellitus 2Angel Arturo Gaona Galdos 23 November 2012 (has links)
O diabetes mellitus (DM) é uma síndrome na qual o metabolismo de hidratos de carbono, gorduras e proteínas está alterado, por falta de secreção de insulina ou por diminuição da sensibilidade tissular a este hormônio. O DM pode ser do tipo I, também denominado diabetes mellitus insulinodependente (DMID), caracterizado pela falta de secreção da insulina, e do tipo II, também denominado diabetes mellitus não insulinodependente (DMNID), caracterizado pela menor sensibilidade dos tecidos efetores às ações metabólicas da insulina. Embora ainda não haja cura definitiva, há vários tratamentos disponíveis que proporcionam qualidade de vida para o paciente portador, como a administração de hipoglicemiantes orais. Nesta pesquisa, objetivou-se desenvolver métodos indicativos de estabilidade para a glibenclamida e o cloridrato de metformina. Assim, foram desenvolvidos métodos de rastreamento ortogonais utilizando a cromatografia líquida de alta eficiência (HPLC) e a eletroforese capilar (CE), metodologias que foram desafiadas com os estudos da degradação forçada. Realizou-se, também, a identificação do principal produto de degradação da glibenclamida utilizando a cromatografia líquida acoplada à espectrometria de massa (LC-MS). O método por HPLC teve o melhor desempenho no monitoramento dos produtos de degradação da glibenclamida, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL; com coeficiente de correlação maior de 0,99. A precisão calculada como desvio padrão relativo (DPR) foi menor de 3%, exatidão do método comprovada mediante teste de recuperação, obtendo-se valores de 100±3,0%. No teste de especificidade, foram detectados três potenciais produtos de degradação, com os seguintes tempos de retenção relativos (TRR) de 0,33; 0,46 e 0,83. O método CZE teve o melhor desempenho no monitoramento dos produtos de degradação do cloridrato de metformina, apresentando boa linearidade nas concentrações entre 0,210 e 0,360 mg/mL, com coeficiente de correlação maior de 0,99. A precisão, calculada como DPR, foi menor do que 5%, exatidão do método comprovada mediante o teste de recuperação, obtendo-se valores de 100±3,5%. No teste de especificidade, foram detectados cinco potenciais produtos de degradação com os seguintes TRRs de 0,90; 1,14; 1,35; 1,45 e 1,56. / Diabetes mellitus (DM) is a syndrome which alters the metabolism of carbohydrates, fats and proteins by lack of insulin secretion or a decrease in tissue sensitivity to insulin. Type 1 DM is also known as insulin-dependent diabetes mellitus is characterized by lack of insulin secretion. The second type of diabetes known as Type II, also called non-insulin dependent, is characterized by the reduced sensitivity of target tissues to the metabolic actions of insulin. Although there is no definitive cure, there are several treatments available that provide quality of life for the patient how treatment with oral hypoglycemic agents. This study had as objective to developed stability-indicating methods for glibenclamide and metformin hydrochloride. Thus, the techniques used in this study involved high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), and both were challenged with forced degradation studies. The identification of degradation products of glibenclamide was also performed, utilizing the mass spectrometry (MS) technique. However, the HPLC technique had the best performance for monitoring the degradation products of glibenclamide, which showed a good linearity in concentrations between 0.210 - 0.360 mg/ml, with a correlation coefficient greater than 0.99. The precision was calculated as a relative standard deviation (RSD) which was less than 3%; the accuracy of the method calculated as the percent recovery was obtained with the following values: 100 ± 3.0%. On the specificity were detected three potential products of degradation utilizing forced degradation, with the following relative retention times (RRT) 0.33, 0.46 and 0.83. The CZE method had the best performance to monitoring the degradation products of metformin hydrochloride, which showed good linearity of concentrations between 0.210 and 0.360 mg/ml, with a correlation coefficient greater than 0.99. The intra-day and inter-day precision calculated as DPR was less than 5%, and an accuracy of this method was achieved using the values of 100 ± 3.5%. In the specificity were five potential degradation products were detected with the following TRRS: 0.90, 1.14, 1.35, 1.45 and 1.56.
|
22 |
Desenvolvimento de metodologias indicativas de estabilidade para medicamentos utilizados como diuréticos / Development of stability-indicating assay for diuretics drugs.Aline de Souza 11 December 2015 (has links)
Os diuréticos aumentam o fluxo urinário e a excreção de sódio e são utilizados para ajustar o volume e/ou a composição dos líquidos corporais em uma variedade de situações clínicas. A furosemida é um agente diurético potente que induz uma poderosa diurese. É utilizada no tratamento de edema associado com o coração e doenças renais. Nesta pesquisa objetivou-se desenvolver métodos indicativos de estabilidade para a furosemida, por eletroforese capilar em solução livre (FSCE) e cromatografia liquida de alta eficiência (CLAE). O método por FSCE utilizou um capilar de sílica fundida com comprimento total de 30,2 cm x 50,0 µm d.i. O tampão utilizado foi tetraborato de sódio 2,0 mmol L-1 e 10% de metanol, injeção hidrodinâmica 0,5 psi/5s, tensão aplicada +25 kV, detecção em 273 nm e temperatura a 25ºC. O tempo de migração da furosemida foi de 1,8 minutos. O método obteve boa linearidade no intervalo de 70,0 a 130,0 µg.mL-1 com coeficiente de correlação maior de 0,99. Os limites de detecção e de quantificação foram 6,2 µg.mL-1 e 20,6 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 2,0%. A repetibilidade e precisão intermediária foram inferiores a 5,0%. A recuperação média foi de 102,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 1,3 2,0 e 2,2 min. O método por CLAE utilizou uma coluna Shim-pack CLC-ODS(M)® (250mm x4.6mm, 5µm). A fase móvel era constituída de acetonitrila:água (50:50) com 0,1% de ácido fórmico. O fluxo foi de 1.0 mL min-1 e detecção em 273 nm e temperatura a 30 ± 1 ºC. O método apresentou boa linearidade nas concentrações entre 7,0 e 13 µg.mL-1; com coeficiente de correlação maior de 0,99. E tempo de retenção para furosemida foi de 4,9 minutos. Os limites de detecção e de quantificação foram 0,6 µg.mL-1 e 1,9 µg.mL-1, respectivamente. A precisão do sistema foi inferior a 1,0%. A repetibilidade e precisão intermediária foram inferiores a 3,0%. A recuperação média foi de 105,1 %. No teste de especificidade, foram detectados três potenciais produtos de degradação com os seguintes tempos de retenção 2,4, 3,1 e 3,8 min. / Diuretics increase urine flow and sodium excretion and are used to adjust volume and / or composition of body fluids in a variety of clinical situations. Furosemide is a potent diuretic agent that induces a strong diuresis. It is used in the treatment of edema associated with heart and kidney disease. This research aimed to develop stability indicative methods for furosemide, by capillary electrophoresis in free solution (FSCE) and high-performance liquid chromatography (HPLC). The method FSCE used a fused silica capillary with a total length of 30.2 cm x 50.0 um di The buffer used was sodium tetraborate 2.0 mmol L-1 and 10% methanol, hydrodynamic injection 0.5 psi / 5s, +25 kV applied voltage, detection at 273 nm and 25 °C. The furosemide migration time was 1.8 minutes. The method achieved good linearity in the range of 70.0 to 130.0 µg.mL-1 with correlation coefficient higher of 0.99. The limits of detection and quantification were 6.2 and 20.6 µg.mL-1 µg.mL-1, respectively. The system accuracy was less than 2.0%. The repeatability and intermediate precision were less than 5.0%. The average recovery was 102.1%. The specificity test detected three potential degradation products with the following retention times 1.3, 2.0 and 2.2 min. The HPLC method used a Shim-pack CLC-ODS (M)® column (250mm x 4.6mm, 5µm). The mobile phase consisted of acetonitrile: water (50:50) with 0.1% formic acid. The flow rate was 1.0 mL min-1, detection at 273 nm and temperature at 30 ± 1°C. The method showed good linearity in concentrations between 7.0 and 13.0 µg.mL-1; with correlation coefficient higher of 0.99. Retention time for furosemide was 4.9 minutes. The limits of detection and quantification were 0.6 µg.mL-1 and 1.9 µg.mL-1, respectively. The system accuracy was less than 1.0%. The repeatability and intermediate precision were less than 3.0%. The average recovery was 105.1%. The specificity test detected three potential degradation products of the following retention times of 2.4, 3.1 and 3.8 min.
|
23 |
Métodos analíticos para determinação de delapril e manidipino aplicáveis a estudos de estabilidade e ao desenvolvimento de método de dissolução para a forma farmacêutica comprimidosTodeschini, Vítor January 2013 (has links)
A associação entre os fármacos delapril (DEL) e manidipino (MAN) apresenta um efeito anti-hipertensivo sinérgico de longa duração, sendo considerada uma importante alternativa no tratamento e controle da hipertensão arterial. O presente trabalho faz referência à utilização de diversas técnicas instrumentais para avaliar a qualidade de DEL e MAN na forma farmacêutica e matérias-primas. Neste sentido, amostras de matérias-primas dos fármacos provenientes de diferentes fornecedores foram analisadas utilizando a calorimetria diferencial exploratória, termogravimetria, difração de raios X, espectrofotometria no infravermelho, espectroscopia Raman e microscopia eletrônica de varredura. Os resultados permitiram observar inconsistências entre as amostras de DEL, provavelmente devido à presença de uma impureza em uma das substâncias, demonstrando a importância da pesquisa e controle dos insumos farmacêuticos, bem como de programas de qualificação de fornecedores. Além disso, metodologias analíticas por espectrofotometria derivada, cromatografia líquida com detecção no ultravioleta (CL-UV) e CL acoplada à espectrometria de massas (EM) foram desenvolvidas objetivando a determinação de DEL e MAN nos comprimidos. Os procedimentos foram validados, cumprindo com os requisitos internacionalmente aceitos para especificidade, linearidade, precisão, exatidão, robustez e limites de detecção e quantificação, além de demonstrarem diferença não significativa (p > 0,05) entre si na quantificação simultânea dos fármacos. A estabilidade dos fármacos nas condições alcalina e fotolítica (para o DEL e MAN, respecivamente) também foi investigada. Através dos métodos por CL-UV e CL-EM pode-se propor a identidade dos principais produtos de degradação formados, os quais não apresentaram evidências de citotoxicidade em estudo utilizando células mononucleares humanas. Além disso, os estudos de cinéticas de degradação indicaram que o DEL segue uma cinética de primeira ordem (R2 = 0,9991) enquanto o MAN segue uma reação de ordem zero (R2 = 0,9867). De forma adicional, foi desenvolvido e validado um método de dissolução para avaliação de comprimidos contendo DEL e MAN. O uso de tampão citrato pH 3,2 como meio de dissolução e dispositivo pá a 75 rpm demonstrou resultados satisfatórios para a avaliação da liberação simultânea dos fármacos do produto farmacêutico, bem como capacidade de simular o comportamento in vivo do MAN a partir de dados da literatura. Desse modo, estabeleceram-se procedimentos analíticos que podem ser aplicados para aprimorar o controle da qualidade dos medicamentos a serem comercializados, bem como contribuir para garantir a segurança e eficácia no uso terapêutico. / The association of delapril (DEL) and manidipine (MAN) has a synergic antihypertensive effect and may be regarded as an important alternative to arterial hypertension treatment. The present study refers to use of some instrumental techniques to assess the quality of DEL and MAN in pharmaceutical formulation and raw materials. In this context, samples of the drugs raw materials, obtained from different suppliers, were evaluated using differential scanning calorimetry, thermogravimety, X-ray powder diffraction, infrared spectroscopy, Raman spectroscopy and scanning electron microscopy. Inconsistent results were observed between DEL samples, probably due to an impurity presence in some substance, demonstrating the importance of research and control of pharmaceutical ingredients, as well as the quality programs of pharmaceuticals suppliers. In addition, a derivative spectrophotometric, liquid chromatography (LC) and LC coupled to mass spectrometry (MS) methods were developed for simultaneous analysis of DEL and MAN in commercial tablets. The procedures were validated and the results were in accordance with internationally accepted requirements by specificity, linearity, precision, accuracy, robustness and detection and quantitation limits. Therefore, the methods were successfully applied for the simultaneous quantitative analysis of DEL and MAN in the tablet dosage form, showing non-significant difference (p > 0.05). The drugs stability in alkaline and photolytic conditions (for DEL and MAN, respectively) was also investigated. The main degradation products formed were analyzed by LC-UV and LC-ESI-MS methods and its identity could be suggested, without isolation or purification processes. Additionally, the degradation kinetic of both drugs and the cytotoxicity of the degraded samples were also studied. No evidence of cytotoxicity in human mononuclear cells was observed for drugs degraded samples. Furthermore, the present study also conducted the development and validation of a dissolution method for DEL and MAN combination tablets. The use of citrate buffer pH 3.2 as dissolution medium in combination with paddle at rotation of 75 rpm, resulted in an appropriate dissolution profile of both drugs, allowing the simultaneous quality control of DEL and MAN in combination tablets, as well as the ability to simulate the in vivo behavior of MAN from literature data. Then, the established procedures can be applied to improve the quality control of the products that will be marketed, as well as to contribute for assure the safety and therapeutic efficacy of the drugs.
|
24 |
Estudo de estabilidade do antibiótico meropenem / Stability study of the antibiotic meropenemMendez, Andreas Sebastian Loureiro January 2007 (has links)
A estabilidade de medicamentos constitui um tema atual e de grande importância no meio científico. Tem sido constantemente abordada em estudos direcionados à avaliação da qualidade das preparações farmacêuticas. O meropenem, um antibiótico carbapenêmico de amplo espectro de ação, é utilizado como um importante recurso terapêutico para o tratamento de infecções graves. Por ser um agente antimicrobiano ativo e eficaz, de uso clínico em muitos países, tornase necessária a pesquisa mais aprofundada de sua estabilidade, propiciando um maior entendimento dos aspectos que podem influenciar na sua manipulação e armazenamento. O presente trabalho objetiva a avaliação da estabilidade do meropenem em condições de degradação forçada, contemplando a determinação da cinética de degradação, o isolamento e identificação de produtos de decomposição e a determinação da citotoxicidade das amostras degradadas e dos produtos isolados. Amostras de meropenem pó para solução injetável (500 mg) e solução reconstituída em água (50 mg/mL) foram submetidas à degradação térmica em diferentes temperaturas. Para a decomposição ácido-base, soluções aquosas de meropenem a 1,0 mg/mL foram preparadas em HCl 0,1 M e NaOH 0,1 M, e estocadas a 25 °C. As amostras foram analisadas por cromatografia líquida de alta eficiência, em sistema de fase reversa. Para o ensaio de determinação cinética, as amostras submetidas à maior temperatura de degradação foram também analisadas por ensaio microbiológico – método de difusão em ágar-cilindros em placas. O isolamento do produto de degradação térmica foi efetuado através da combinação das técnicas de cromatografia em coluna e cromatografia em camada delgada preparativa. Para o produto oriundo de catálise básica, a identificação foi efetuada diretamente na amostra degradada, não havendo a necessidade de prévio isolamento. A elucidação estrutural dos produtos de degradação foi realizada por ressonância magnética nuclear e espectrometria de massas. As amostras degradadas e o produto de catálise básica foram avaliados in vitro quanto ao potencial citotóxico frente a células mononucleares. Para determinação da viabilidade celular, os conteúdos celulares foram avaliados por citometria de fluxo. Os resultados dos ensaios de cinética química indicaram que o meropenem sofre decomposição térmica seguindo reação de primeira ordem. As amostras degradadas apresentaram uma acentuada redução de teor, com formação de produtos de degradação. As técnicas cromatográficas de purificação utilizadas permitiram o isolamento de um produto oriundo da degradação térmica da solução reconstituída. A identificação demonstrou que o mesmo teve uma modificação estrutural extensa, gerada a partir de reações de decomposição passíveis de ocorrer para o derivado carbapenêmico avaliado. Para o produto de degradação básica, verificou-se o rompimento do anel β-lactâmico, em reação característica destes compostos. A avaliação preliminar da citotoxicidade indicou que as amostras ensaiadas apresentam toxicidade celular in vitro após 48 horas de incubação, fornecendo indícios de necessidade de atenção para este aspecto. A totalidade dos resultados obtidos neste trabalho permite a conclusão de que a estabilidade do meropenem é um tema de grande relevância e deve ser considerada na hora da manipulação do produto, de modo a evitar problemas de qualidade oriundos de amostras degradadas e seus produtos de degradação. / The stability of pharmaceuticals is a current and important subject in the scientific field. It has been frequently cited in studies related with the quality evaluation of pharmaceutical preparations. Meropenem, a carbapenemic antibiotic with broad spectrum, is used as an important therapeutic agent for the treatment of several infections. Since it is an active and effective antimicrobial, used in many countries, it is necessary the complete research about its stability, providing more knowledge about the aspects that could influence in its handle and storage. The aim of this work is the evaluation of meropenem stability in forced degradation conditions, including the determination of degradation kinetics, the isolation and identification of decomposition products and the citotoxicity evaluation of degraded samples and isolated products. Meropenem powder for injection (500 mg) and reconstituted solution in water (50 mg ml-1) were submitted to thermal degradation. For acid-basic decomposition, meropenem aqueous solution at 1.0 mg ml-1 were prepared in HCl 0.1 M and NaOH 0.1 M, and stored at 25 °C. The samples were analysed by high performance liquid chromatography, in reverse phase system. In the kinetics determination, the samples stored at 45 °C and 90 °C were also evaluated by microbiological assay, applying the cylinder-plate method. The isolation of thermal degradation product was carried out by column chromatography and preparative thin layer chromatography. For the product obtained through basic catalysis, the identification was done directly in the degraded sample, without previous isolation. The structural elucidation of degradation products was performed by nuclear magnetic ressonance and mass spectrometry. The degraded samples and basic catalysis product were evaluated with respect to citotoxic potential in vitro against mononuclear cells. The cellular viability was determined by flow citometry. The results of chemical kinetics indicated that thermal decomposition of meropenem is described by first order reaction. The degraded samples showed a significant reduction in the potency, with formation of degradation products. The chromatographic purification techniques allowed the isolation of one thermal degradation product. For the basic degradation product, it was verified the hidrolysis of β-lactam ring, in a caracterisitc reaction for these compounds. The preliminary citotoxicity evaluation indicated that samples were toxic after 48 hours. The results obtained in this work allowed to conclude that the stability of meropenem is a subject of great importance and should be considered in the handle of the product, in order to avoid quality problems from degraded samples and degradation products.
|
25 |
Cloridrato de milnaciprana cápsulas : metodologia analítica, ensaio de dissolução e estudo de estabilidade / Milnacipran hydrochloride capsules: analytical methodology, dissolution test and study of stabilityDias, Carolina Lupi January 2011 (has links)
O cloridrato de milnaciprana (MNC) é um inibidor da recaptação da serotonina e noradrenalina (IRSN), produzido na forma farmacêutica cápsula, Ixel, Dalcipran e Toledomin, para o tratamento da depressão, e como comprimido, sob o nome comercial Savella, indicado no manejo da fibromialgia. Levando-se em consideração que não existem métodos oficiais para o doseamento do MNC em produto acabado, faz-se necessário o desenvolvimento e validação de métodos para assegurar a qualidade da forma farmacêutica. Deste modo, o objetivo deste trabalho foi a validação de métodos analíticos para o controle de qualidade do MNC cápsulas e a realização de estudo da degradação forçada do fármaco. A identificação e caracterização do fármaco foram realizadas através da análise do ponto de fusão, DSC, rotação específica e IV. Para a quantificação foram validados, segundo normas da ICH, os métodos UV-D2, CLAE e EC. A análise estatística demonstrou equivalência entre os métodos UV-D2 e CLAE, assim como entre CLAE e EC, para doseamento do MNC cápsulas. O teste de dissolução foi desenvolvido e validado utilizando cestas (50 rpm) em HCl 0,01M como meio de dissolução. A porcentagem de fármaco dissolvido foi determinada por ambos os métodos, CLAE e UV-D2. Os parâmetros cinéticos (ED% e t80%) da dissolução foram determinados e o modelo de Hixson-Crowell é o que melhor descreve a cinética de dissolução das cápsulas. A influência das condições de armazenamento da formulação farmacêutica no perfil de dissolução também foi avaliada. No estudo de degradação forçada, o MNC foi submetido à radiação UV (254 nm) e à oxidação com peróxido de hidrogênio. A CLAE foi o método empregado na análise do teor e pureza das amostras submetidas às degradações. Os resultados demonstraram a sensibilidade do fármaco nas condições testadas, havendo redução significativa de seu teor e a formação de produtos de degradação. A fotodegradação do MNC demonstrou cinética de 1ª ordem para o fármaco no estado sólido e para a solução das cápsulas, enquanto para o fármaco em solução demonstrou cinética de ordem zero. / Milnacipran hydrochloride (MNC) is a serotonin and noradrenaline reuptake inhibitor (SNRI), produced as capsules, Ixel, Dalcipran and Toledomin, for the treatment of depression, and as tablets, under the trade name Savella, indicated in the management of fibromyalgia. Considering that there are no official methods for the determination of the MNC capsules, it is necessary to develop and validate methods to ensure the quality of pharmaceutical formulation. Thus, the objective of this study was the validation of analytical methods for quality control of the MNC capsules and the forced degradation studies of the drug. The identification and characterization of the drug were performed by analyzing the melting point, DSC, specific rotation and IR. For the quantification were validated a second-derivative UV spectrophotometric (UV-D2), HPLC and a CE methods, according to ICH guide. Statistical analysis showed that the methods UV-D2 / HPLC, and HPLC / CE were equivalent to assay MNC capsules. The dissolution test was developed and validated using baskets (50 rpm) in 0.01N HCl as dissolution medium. The percentage of dissolved drug was determined by both methods (HPLC and UV-D2). The kinetic parameters (dissolution efficiency% and t80%) of drug release were determined and the Hixson-Crowell model is which best describes the dissolution kinetics of the capsules. The influence of storage conditions of the pharmaceutical formulation in the dissolution rate was also evaluated. In forced degradation study, the MNC was subjected to UV (254nm) and oxidation with hydrogen peroxide. The HPLC method was employed to analyze the assay and purity of samples subjected to degradation. The results showed levels of the drug decreased significantly and the presence of its degradation products. The photodegradation of MNC showed first order kinetics of reaction to the drug at solid state and to capsules solution, but the drug solution presented zero order kinetics.
|
26 |
Cefpiroma : desenvolvimento e validação de métodos analíticos e estudo da estabilidadeOppe, Tercio Paschke January 2007 (has links)
Neste trabalho, foram desenvolvidos e validados métodos qualitativos e quantitativos para o controle de qualidade de cefpiroma, antibiótico β-lactâmico de amplo espectro utilizado, principalmente, no tratamento de infecções graves e episódios febris em pacientes com neutropenia, na forma farmacêutica pó para solução injetável. A substância química de referência utilizada nas análises foi caracterizada por espectrofotometria no infravermelho e por espectroscopia de ressonância magnética nuclear. A análise qualitativa foi realizada por cromatografia em camada delgada, determinação da faixa de fusão, espectrofotometria nas regiões do ultravioleta e do infravermelho e cromatografia líquida de alta eficiência, possibilitando a identificação da amostra. A determinação quantitativa foi realizada através dos métodos: espectrofotometria no ultravioleta, cromatografia líquida de alta eficiência e ensaio microbiológico pelo método de difusão em ágar – cilindros em placas, delineamento 3 x 3. Os métodos propostos foram validados segundo guias oficiais e demonstraram ser específicos, lineares, precisos e exatos. Os resultados obtidos demonstraram não haver diferença significativa entre os métodos quando comparados estatisticamente pela análise de variância (ANOVA). Outro objetivo deste trabalho foi o estudo da estabilidade da cefpiroma na forma farmacêutica reconstituída com água para injetável. Os fatores de degradação avaliados foram temperatura (40 ºC) e luz (UVC – 254 nm). Os estudos acelerados de estabilidade demonstraram que a cinética de degradação térmica e fotoquímica foi de primeira ordem. Um produto de degradação térmica foi isolado e identificado, por ressonância magnética nuclear, espectrofometria no infravermelho e espectroscopia de massa, como sulfato de 6-7-diidro-5H-ciclopenta[b]piridinium. / The aim of this study was the development and validation of analytical methods to the determination of cefpirome in powder for injectable preparation and the stability study of the drug after reconstitution of the pharmaceutical dosage form with injectable water. Cefpirome is a fourth-generation cephalosporin active against a broad spectrum of gram-negative and gram-positive bacterial infections and its principal indication is in the treatment of patients’ septic shock or several sepsis. The substance used as reference standard in the analysis was characterized by infrared spectroscopy and nuclear magnetic resonance. The qualitative analysis was performed by thin layer chromatography, melting range determination, infrared and ultraviolet spectroscopy and high performance liquid chromatography, allowing the identification of samples. The quantitative determination was performed by ultraviolet spectrophotometry, high performance liquid chromatography and cylinder-plate microbiological assay (3 x 3). The proposed methods were validated following official guides and all of them demonstrated to be specific, linear, precise and accurate. The obtained results were analyzed by the ANOVA method and they are not statistically different. The degradation factors evaluated were the temperature (40 ºC) and light (UVC – 254 nm) and the accelerated stability demonstrated that the degradation kinetics from thermal and photo degradation were first-order reactions. A thermal degradation product was isolated and identified, by nuclear magnetic resonance, infrared spectroscopy and mass spectrometry, as 6-7-dihidro-5Hcyclopenta[ b]pyridinium sulfate.
|
27 |
Utilização da espectrometria de massas no estudo de produtos de transformação/degradação de fármacos de uso humano e veterinárioSegalin, Jéferson January 2015 (has links)
A espectrometria de massas, acoplada ou não a outras técnicas, tem sido de grande utilidade na determinação de novos compostos, produtos de transformação/degradação, metabólitos e na quantificação em nível de traços nas mais diferentes matrizes, devido à grande versatilidade dessa técnica, especialmente em relação aos modos de análise. Neste trabalho foi sistematizada uma metodologia para a aplicação das técnicas de espectrometria de massas na identificação de produtos de transformação/degradação de fármacos de uso humano e veterinário. Ferramentas da química computacional foram utilizadas para auxiliar na elucidação das estruturas dos compostos formados. A metodologia foi empregada para a identificação e quantificação dos produtos de transformação/degradação da rosuvastatina, gerados durante o processo de fotocatálise heterogênea com ZnO, para a identificação dos produtos de transformação/degradação gerados durante a fotólise em meio aquoso do sulfamentoxazol, ciprofloxacino e norfloxacino, e para a quantificação da amoxicilina transferida ao leite bovino. A viabilidade de se realizar a identificação de metabólitos da amoxicilina presentes no leite bovino por meio do mesmo processo de preparo de amostra e de análise utilizado para a quantificação também foi avaliada. Foram identificados dez principais produtos de transformação/degradação da fotocatálise da rosuvstatina, dez principais produtos de transformação/degradação da fotólise em meio aquoso do sulfametoxazol, quinze principais produtos de transformação/degradação da fotólise em meio aquoso do ciprofloxacino e quinze principais produtos de transformação/degradação da fotólise em meio aquoso do norfloxacino. A metodologia empregada para a quantificação da amoxicilina em leite bovino se demostrou adequada, mas estudos adicionais são necessários para que seja possível identificar os seus metabólitos nessa matriz. Os resultados dos cálculos ab initio que foram utilizados para o estudo dos produtos de transformação/degradação da rosuvastatina e sulfametoxazol mostram que essa técnica pode ser bastante útil na elucidação estrutural dos compostos que são formados. / Mass spectrometry, coupled or not with other techniques, is very useful for the determination of new compounds, transformation/degradation products, metabolites and quantification at trace levels in many different matrices, due to the versatility of such a technique, specially regarding to analysis modes. In the present work a methodology was systematized for the application of mass spectrometry techniques in order to identify metabolites and transformation/degradation products for human and veterinary drugs usage. Computational chemistry tools were used to assist in the elucidation of the structure of the compounds formed during the process. The methodology was employed for identification and quantification of rosuvastatin transformation/degradation products generated during the heterogeneous photocatalysis process with ZnO, for the identification of sulfamethoxazole, ciprofloxacin and norfloxacion transformation/degradation products generated during the photolysis in aqueous medium and for quantifying amoxicillin transferred to bovine milk. The feasibility of identification of amoxicillin metabolites present in bovine milk using the same sample preparation procedure exploited for the quantification analysis was also assessed. Ten main transformation/degradation products of rosuvastatin photocatalysis were identified, as well as ten main transformation/degradation products of sulfamethoxaxole photolysis in aqueous medium, fifteen main transformation/degradation products of ciprofloxacin photolysis in aqueous medium and fifteen main transformation/degradation products of norfloxacin photolysis in aqueous medium. The methodology applied for the bovine milk amoxicillin quantification was demonstrated to be adequate, but additional studies are needed to identify amoxicillin metabolites in the milk matrix. The results of ab initio calculations utilised for the study of rosuvastatin and sulfamethoxazole transformation/degradation products show that this technique can be very useful for the structural elucidation of chemical compounds which are formed.
|
28 |
Métodos analíticos para determinação de delapril e manidipino aplicáveis a estudos de estabilidade e ao desenvolvimento de método de dissolução para a forma farmacêutica comprimidosTodeschini, Vítor January 2013 (has links)
A associação entre os fármacos delapril (DEL) e manidipino (MAN) apresenta um efeito anti-hipertensivo sinérgico de longa duração, sendo considerada uma importante alternativa no tratamento e controle da hipertensão arterial. O presente trabalho faz referência à utilização de diversas técnicas instrumentais para avaliar a qualidade de DEL e MAN na forma farmacêutica e matérias-primas. Neste sentido, amostras de matérias-primas dos fármacos provenientes de diferentes fornecedores foram analisadas utilizando a calorimetria diferencial exploratória, termogravimetria, difração de raios X, espectrofotometria no infravermelho, espectroscopia Raman e microscopia eletrônica de varredura. Os resultados permitiram observar inconsistências entre as amostras de DEL, provavelmente devido à presença de uma impureza em uma das substâncias, demonstrando a importância da pesquisa e controle dos insumos farmacêuticos, bem como de programas de qualificação de fornecedores. Além disso, metodologias analíticas por espectrofotometria derivada, cromatografia líquida com detecção no ultravioleta (CL-UV) e CL acoplada à espectrometria de massas (EM) foram desenvolvidas objetivando a determinação de DEL e MAN nos comprimidos. Os procedimentos foram validados, cumprindo com os requisitos internacionalmente aceitos para especificidade, linearidade, precisão, exatidão, robustez e limites de detecção e quantificação, além de demonstrarem diferença não significativa (p > 0,05) entre si na quantificação simultânea dos fármacos. A estabilidade dos fármacos nas condições alcalina e fotolítica (para o DEL e MAN, respecivamente) também foi investigada. Através dos métodos por CL-UV e CL-EM pode-se propor a identidade dos principais produtos de degradação formados, os quais não apresentaram evidências de citotoxicidade em estudo utilizando células mononucleares humanas. Além disso, os estudos de cinéticas de degradação indicaram que o DEL segue uma cinética de primeira ordem (R2 = 0,9991) enquanto o MAN segue uma reação de ordem zero (R2 = 0,9867). De forma adicional, foi desenvolvido e validado um método de dissolução para avaliação de comprimidos contendo DEL e MAN. O uso de tampão citrato pH 3,2 como meio de dissolução e dispositivo pá a 75 rpm demonstrou resultados satisfatórios para a avaliação da liberação simultânea dos fármacos do produto farmacêutico, bem como capacidade de simular o comportamento in vivo do MAN a partir de dados da literatura. Desse modo, estabeleceram-se procedimentos analíticos que podem ser aplicados para aprimorar o controle da qualidade dos medicamentos a serem comercializados, bem como contribuir para garantir a segurança e eficácia no uso terapêutico. / The association of delapril (DEL) and manidipine (MAN) has a synergic antihypertensive effect and may be regarded as an important alternative to arterial hypertension treatment. The present study refers to use of some instrumental techniques to assess the quality of DEL and MAN in pharmaceutical formulation and raw materials. In this context, samples of the drugs raw materials, obtained from different suppliers, were evaluated using differential scanning calorimetry, thermogravimety, X-ray powder diffraction, infrared spectroscopy, Raman spectroscopy and scanning electron microscopy. Inconsistent results were observed between DEL samples, probably due to an impurity presence in some substance, demonstrating the importance of research and control of pharmaceutical ingredients, as well as the quality programs of pharmaceuticals suppliers. In addition, a derivative spectrophotometric, liquid chromatography (LC) and LC coupled to mass spectrometry (MS) methods were developed for simultaneous analysis of DEL and MAN in commercial tablets. The procedures were validated and the results were in accordance with internationally accepted requirements by specificity, linearity, precision, accuracy, robustness and detection and quantitation limits. Therefore, the methods were successfully applied for the simultaneous quantitative analysis of DEL and MAN in the tablet dosage form, showing non-significant difference (p > 0.05). The drugs stability in alkaline and photolytic conditions (for DEL and MAN, respectively) was also investigated. The main degradation products formed were analyzed by LC-UV and LC-ESI-MS methods and its identity could be suggested, without isolation or purification processes. Additionally, the degradation kinetic of both drugs and the cytotoxicity of the degraded samples were also studied. No evidence of cytotoxicity in human mononuclear cells was observed for drugs degraded samples. Furthermore, the present study also conducted the development and validation of a dissolution method for DEL and MAN combination tablets. The use of citrate buffer pH 3.2 as dissolution medium in combination with paddle at rotation of 75 rpm, resulted in an appropriate dissolution profile of both drugs, allowing the simultaneous quality control of DEL and MAN in combination tablets, as well as the ability to simulate the in vivo behavior of MAN from literature data. Then, the established procedures can be applied to improve the quality control of the products that will be marketed, as well as to contribute for assure the safety and therapeutic efficacy of the drugs.
|
29 |
Antibióticos macrolídeos: determinação e identificação de metabólitos e subprodutos de degradação em efluente hospitalar / Macrolides antibiotics: determination and identification of metabolites and degradation subproducts in hospital effluentMinetto, Luciane 09 August 2013 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Macrolide antibiotics are an important group of prescription drugs; as a consequence of the large and continuous use, they are commonly found in the environment.
In the present study, it was developed and optimized a chromatographic method to assess the occurrence of macrolide antibiotics Azithromycin, Clarithromycin, Erythromycin and Roxithromycin in the effluent of the University Hospital of Santa Maria, in two sampling points, by applying high performance liquid chromatography coupled to mass detection with quadrupole ion trap (HPLC-MS/MS_QTrap) and clean-up/pre-concentration by solid phase extraction with the aid of Surface Methodology Response. The concentrations measured during a week in the hospital effluent were 1.32±0.13 and 0.22±0.06 μg L-1 for Azithromycin and Clarithromycin; in the receptor water sream was 1.12±0.20, 0.20±0.05 and 0.01±0.004 μg L-1 for Azithromycin, Clarithromycin and Erythromycin. Roxithromycin was not detected in all effluent samples. After this, it was done the evaluation of the risk quotient of the macrolide antibiotics. The value of the risk quotient for the hospital effluent for Azithromycin and Clarithromycin was 11 (high risk), and for the receptor water stream the risk quotient was 9.3 and 10.0 for Azithromycin and Clarithromycin; for Erythromycin, a quocient risk value of 0.5 (medium risk).
For degradation of the antibiotics in aqueous solution, it was used UV-photolysis, by which the influence of pH (3-11) was evaluated. Azithromycin showed low degradation by acid pH; for other pH, as well, for all the other antibiotics, the degradation was above 70% after 60 min of treatment. It was conducted a kinetic study of the degradation process of macrolide antibiotics in different pHs, by which Azithromycin revealed a recalcitrant profile, and Roxithromycin, as the more easily degradable one.
For identification of the products formed during the photolysis experiments it was used independent information acquisition and as precursor ions of fragments m/z 116 and 158, characteristic of the macrolide compounds, at three collision energies (30, 45, and 60 V). It was proposed fragmentation routes of the degradation products: 8 products for Azithromycin, 7 for Clarithromycin, 6 of Erythromycin and 8 Roxithromycin. Through the same experiments with independent information acquisition, it was investigated the presence of eventual metabolites in hospital effluent, and three metabolites were found.
By applying photolysis to the hospital effluent fortified, at pH 7, it was observed that the degradation occurs above 80% for all compounds after 60 min of irradiation. It was observed the formation of degradation products previously determined by experiments in aqueous solution. It was also found three degradation products for Azithromycin, 2 for Clarithromycin, 1 for Erythromycin and 3 for Roxithromycin. / Os antibióticos macrolídeos são uma importante classe de fármacos preescritos no tratamento das mais variadas infecções, e como consequência se seu grande e continuo uso são comumente encontradas no ambiente.
No presente estudo foi desenvolvido e otimizado método de cromatografia líquida de alta eficiência acoplada à detector de massas quadrupolo íon trap (HPLC-MS/MS_QTrap) e de clean-up/pré-concentração por extração em fase sólida com auxílio de Metodologia de Superfície de Resposta para avaliar a ocorrência dos antibióticos macrolídeos Azitromicina, Claritromicina, Eritromicina e Roxitromicina no efluente hospitalar do Hospital Universitário de Santa Maria em dois ponto de amostragem. As concentrações médias durante o ciclo de uma semana de amostragem no efluente do pronto atendimento foram de 1,32±0,13 e 0,22±0,06 g L-1 para Azitromicina e Claritromicina; no corpo recpetor foram de 1,12±0,20; 0,20±0,05 e 0,01±0,004 g L-1 para Azitromicina, Claritromicina e Eritromicina, respectivamente. Roxitromicina não foi detectada. Após foi feita a avaliação do quociente de risco dos antibióticos macrolídeos. O quociente de risco no efluente do pronto atendimento para Azitromicina e Claritromicina foi de 11, risco alto, o qual também foi evidenciado no corpo receptor com quociente de risco de 9,3 e 10 para Azitromicina e Claritromicna, e risco médio para Eritromicina de 0,5.
Para degradação dos antibióticos foi utilizado fotólise artificial em solução aquosa, sendo avaliado a influência do pH de 3-11 na degradação destes compostos. Azitromicina apresentou baixa degradação em pH ácido, para os outros pH e demais compostos a degradação foi acima de 70% após 60 min de tratamento. Foi feito um estudo cinético do processo de degradação dos antibióticos macrolídeos em diferentes pH, observando-se que a Azitromicina apresentou um perfil recalcitrante para o processo, e Roxitromicina foi degradada com maior facilidade.
Para a identificação dos produtos formados durante os experimentos de fotodegradação foram montados experimentos de informação independente de aquisição utilizando como íons precursores os íons de m/z 116 e 158 característicos dos compostos macrolídeos em três energias de colisão (30, 45 e 60 V). Foram identificadas e propostas rotas de fragmentação para 8 produtos de degradação de Azitromicina, 7 para Claritromicina, 6 para Eritromicina e 8 produtos de degradação de Roxiromicina. Através dos mesmos experimentos de informação independente de aquisição, foi investigada a presença de possíveis metabólitos no efluente hospitalar sendo encontrados 3 metabólitos. Com a aplicação de fotólise ao efluente hospitalar fortificado, em pH 7, observou-se que ocorre degradação acima de 80% para todos os compostos após 60 min de tratamneto. Foi observada a formação de produtos de degradação, que tinham sido previamente determinados em solução aquosa. Foram encontrados 3 produtos de degradação de Azitromicina, 2 para Claritromicina, 1 para Eritromicina e 3 produtos para Roxitromicina.
|
30 |
Cefpiroma : desenvolvimento e validação de métodos analíticos e estudo da estabilidadeOppe, Tercio Paschke January 2007 (has links)
Neste trabalho, foram desenvolvidos e validados métodos qualitativos e quantitativos para o controle de qualidade de cefpiroma, antibiótico β-lactâmico de amplo espectro utilizado, principalmente, no tratamento de infecções graves e episódios febris em pacientes com neutropenia, na forma farmacêutica pó para solução injetável. A substância química de referência utilizada nas análises foi caracterizada por espectrofotometria no infravermelho e por espectroscopia de ressonância magnética nuclear. A análise qualitativa foi realizada por cromatografia em camada delgada, determinação da faixa de fusão, espectrofotometria nas regiões do ultravioleta e do infravermelho e cromatografia líquida de alta eficiência, possibilitando a identificação da amostra. A determinação quantitativa foi realizada através dos métodos: espectrofotometria no ultravioleta, cromatografia líquida de alta eficiência e ensaio microbiológico pelo método de difusão em ágar – cilindros em placas, delineamento 3 x 3. Os métodos propostos foram validados segundo guias oficiais e demonstraram ser específicos, lineares, precisos e exatos. Os resultados obtidos demonstraram não haver diferença significativa entre os métodos quando comparados estatisticamente pela análise de variância (ANOVA). Outro objetivo deste trabalho foi o estudo da estabilidade da cefpiroma na forma farmacêutica reconstituída com água para injetável. Os fatores de degradação avaliados foram temperatura (40 ºC) e luz (UVC – 254 nm). Os estudos acelerados de estabilidade demonstraram que a cinética de degradação térmica e fotoquímica foi de primeira ordem. Um produto de degradação térmica foi isolado e identificado, por ressonância magnética nuclear, espectrofometria no infravermelho e espectroscopia de massa, como sulfato de 6-7-diidro-5H-ciclopenta[b]piridinium. / The aim of this study was the development and validation of analytical methods to the determination of cefpirome in powder for injectable preparation and the stability study of the drug after reconstitution of the pharmaceutical dosage form with injectable water. Cefpirome is a fourth-generation cephalosporin active against a broad spectrum of gram-negative and gram-positive bacterial infections and its principal indication is in the treatment of patients’ septic shock or several sepsis. The substance used as reference standard in the analysis was characterized by infrared spectroscopy and nuclear magnetic resonance. The qualitative analysis was performed by thin layer chromatography, melting range determination, infrared and ultraviolet spectroscopy and high performance liquid chromatography, allowing the identification of samples. The quantitative determination was performed by ultraviolet spectrophotometry, high performance liquid chromatography and cylinder-plate microbiological assay (3 x 3). The proposed methods were validated following official guides and all of them demonstrated to be specific, linear, precise and accurate. The obtained results were analyzed by the ANOVA method and they are not statistically different. The degradation factors evaluated were the temperature (40 ºC) and light (UVC – 254 nm) and the accelerated stability demonstrated that the degradation kinetics from thermal and photo degradation were first-order reactions. A thermal degradation product was isolated and identified, by nuclear magnetic resonance, infrared spectroscopy and mass spectrometry, as 6-7-dihidro-5Hcyclopenta[ b]pyridinium sulfate.
|
Page generated in 0.0785 seconds