• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
631

The development of facial prosthetics and adhesives in plastic and reconstructive surgery : a study in the application of prosthetic materials and devices used in plastic and reconstructive surgery together with tissue adhesives as an alternative to conventional ligation

Roberts, Alan Clive January 1988 (has links)
Various silicone elastomers have been evaluated for use in the prosthetic reconstruction of facial defects. Their strength, texture, flexibility, hardness, ease of preparation, pigment receptivity and retention, and their resistance to cleaning were compared and the data consulted when an elastomer was chosen to restore defects, improve aesthetics and reestablish the confidence of a selection of patients. Detailed case reports are provided, together with information on the adhesives or mechanical methods available for retaining the facial prosetheses. Cyanoacrylate adhesives for use on skin surfaces and as tissue adhesives have been studied in detail. A novel n-butyl 413 cyanoacrylate has been developed with a viscosity, haemostatic property and stability to make it particularly suitable for use in skin grafting and tissue repair. It has already been used with good results on patients with severe burns. An improved formulation, containing a fluorescent dye, can be precisely applied through a specially constructed foot-controlled dispenser illuminated by a fibre-optic supplying UV-light. Cyanoacrylates are already being used as tissue adhesives in place of the conventional but potentially disfiguring suture. The availability of improved, imperceptible adhesives and a precision applicator, which can be used in a modern operating theatre, will extend their effectiveness and satisfy some of the needs of Plastic, and Oral and Maxillo-Facial Surgeons. Portable applicators have potential use in battlefield and in veterinary surgery and overcome the imprecision characteristic of earlier methods.
632

Développement de nouvelles matrices de micro-électrodes pour l’analyse et la compréhension du système nerveux central / Development of new Micro Electrode Array to understand dynamics of large neural network

Rousseau, Lionel 13 January 2010 (has links)
La compréhension et l'étude du système nerveux est un des grands enjeux du XXIème siècle à la fois pour la recherche fondamentale, mais également pour la mise au point de neuroprothèses implantables pour la réhabilitation fonctionnelle (exemple : implants rétiniens, implants cochléaires). Depuis quelques années, des systèmes basés sur l'utilisation de multi-électrodes (MEA : Multi-Electrode-Array) offrent la possibilité d'enregistrer des milliers de cellules interconnectées entre-elles sur plusieurs jours sur des tranches de tissu nerveux ou des systèmes nerveux complets. Mais une des limites de cette technique est le faible nombre de voies de ces systèmes (64 voies). Les travaux de cette thèse ont consisté à développer une technologie de fabrication permettant la réalisation d'un système multiélectrode s « haute densité 3D ». Cela passe par le développement d'une nouvelle technologie dans la réalisation de micro pointes basée sur la gravure profonde du silicium (DRIE), qui permet d'obtenir des pointes en silicium de 80 µm de haut espacées de 50 µm. Des matrices 60, 256 et 1024 voies ont été fabriquées par cette technique. L'utilisation de la stimulation est aussi un point important dans l'étude de ces grands réseaux, mais il n'est pas possible actuellement de disposer de système permettant une stimulation focale. Pour résoudre ce problème, nous avons développé des matrices spécifiques permettant d'obtenir des stimulations focales du tissu. Nous avons également dans ces travaux de thèse étudié le comportement de l'interface métal/liquide, qui est cruciale pour la réalisation de MEA, en utilisant des techniques d'électrochimie / One challenge of the XXIème century will be to understand dynamics of large neural networks for research and to develop neuroprothesis implant (ex retinal implant, cochlear implant). Today microelectrodes arrays (MEAs) positioned in contact with the neural tissue offer the opportunity to record and simulate neuronal tissue. But the main drawback of his technique is low number of recording sites (typically 64). During this thesis, we have developed a specific process using deep reactive ions etching (DRIE), to achieve high density 3D MEAs containing several hundreds of microelectrodes. We have fabricated microneedles 80 µm of height with spacing of 50 µm and MEAs with 60 – 256 and 1024 microelectrodes have been built with this process. Microstimulation, which makes use of electrodes on the micron scale, is gaining increasing interest in both fundamental and clinical research, opening the possibility to stimulate small groups of neurons instead of large regions. However, controlling the spatial extent of microstimulation to achieve focal activation of neuron networks is a challenge. We have proposed a new configuration of MEA specifically designed to achieve a local stimulation. We have also characterised the interface metal/liquid, that was very important for MEA and we have used electrochemistry techniques
633

Metodika práce ergoterapeuta u pacientů s myoelektrickou protézou / Occupational therapist's methodics of work for patients with myoelectric prosthesis

Hoidekrová, Kristýna January 2016 (has links)
The aim of this study was to develop methodics of occupational therapy for patients with moelectric prosthesis, which is used by patients with amputation of upper limbs as well as patients with congenital problems. In the Czech republic there are no complex methodics about occupational therapy and myoelectric prosthesis, despite the huge mount of foreign studies of this topic. Myoelectric prosthesis uses the principle of sensing myoelectrical signals which are then transformed to the motor output in the terminal portion of the prosthesis. Occupational therapy intervention begins at the preprosthetic phase, the occupational therapist assesses the general potential for the use of myoelectric prosthesis and picks up myoelectric signals from the stump. In interprosthetic phase occupational therapist is dedicated to the training of activities of daily living with myoelectric prosthesis and training residual stump on the basis of myotest. The phase after prosthetic content of occupational therapy evaluation and assessment, which focus on patients ability of myoelectric control and prosthesis involvement in activities of daily living and training of grip. Within the training of grip, occupational therapist is dedicated to training proper grip within the pace, grip strength and targeted movements. The...
634

Avaliação comparativa da influência do tratamento superficial e do agente cimentante na retenção de núcleos metálicos fundidos em titânio c.p. / Comparative evaluation of the influence of superficial treatment and luting agent to the tensile strength of titanium cast post and cores

Menani, Luiz Ricardo 21 December 2005 (has links)
O uso de núcleos metálicos fundidos é comum na Odontologia Restauradora para promover a substituição de estruturas perdidas em dentes tratados endodonticamente. Estes núcleos podem ser fundidos em ligas nobres ou ligas básicas: as ligas alternativas apresentam vantagens mas são susceptíveis à corrosão. O titânio foi introduzido na Odontologia com o objetivo de compensar as deficiências dos metais básicos, principalmente a corrosão e seus produtos. Então, a proposta deste estudo foi comparar a resistência à tração de núcleos metálicos fundidos confeccionados em liga de ouro tipo III, titânio e titânio tratado superficialmente com solução de Kroll quando fixados com diferentes agentes cimentantes. Quarenta e dois caninos humanos extraídos foram selecionados, a porção coronária foi removida e a raiz remanescente foi tratada endodonticamente. Todos os espécimes foram divididos em seis grupos (n=7). O espaço para pino foi preparado a uma profundidade de 10mm usando-se brocas de Largo. Os núcleos foram fundidos em liga de ouro tipo III e titânio c.p. e fixados com cimento de fosfato de zinco ou cimento resinoso (Panavia F). A resistência à tração foi determinada em uma máquina universal de ensaios a uma velocidade de 0,5mm/min utilizando-se uma célula de carga de 50 Kgf. Os resultados foram analisados estatisticamente por ANOVA, demonstrando que não houve diferença estatisticamente significante entre os grupos. Dentro das limitações deste estudo pode-se concluir que os núcleos metálicos fundidos em titânio c.p. fixados com cimento fosfato de zinco ou cimento resinoso são uma alternativa viável aos núcleos metálicos fundidos em ouro. / The use of cast post and core is common in restorative dentistry to provide long-term tooth structure replacement for endodontically treated teeth. They could be cast in precious or basic alloys: the alternative alloys present advantages but they are susceptible to corrosion and its effects. The titanium was introduced to Dentistry with the objective of compensating the metal basic deficiencies, mainly the corrosion. Then, the purpose of this study was to compare the tensile resistance among gold alloy, titanium, and titanium after a superficial treatment with Kroll’s solution when fixed with different luting agents. Forty two human extracted canines were selected, the coronal aspect of each tooth was removed and the remaining root received endodontic therapy. All specimen were divided into six groups (n=7). The post space was prepared at a depth of 10mm using a Largo’s drill. The cast post and core were manufactured using a type III gold alloy and titanium. Cast post and core were fixed with zinc phosphate or resin luting agent (Panavia F). Tensile bond strength of the specimens was measured with a universal testing machine at a crosshead speed of 0,5mm/min and cell-load of 50 Kgf. Data (Kgf) were statistically analyzed by ANOVA. The results demonstrated that there was not a significant difference among the groups. Within the limitations of this study it has been conclude that the titanium fixed with zinc phosphate or resin luting agent is a viable alternative to the gold alloy to fabricate cast post and cores.
635

Análise fotoelástica comparativa entre pilares protéticos sólidos e de parafuso passante para implantes com conexão cônica instalados em diferentes profundidades ósseas / Comparative photoelastic analysis between standard and regular ankylos abutments in conical abutment connection implants installed in different bone depths

Provinciatti, Mauricio Martins 22 January 2016 (has links)
As tensões de baixa intensidade contribuem para a remodelação óssea nos implantes osseointegráveis, enquanto as tensões de alta intensidade causam a reabsorção óssea abaixo da interface implante-pilar. A sobrecarga oclusal afeta a fisiologia do tecido ósseo, rompendo com o equilíbrio entre a neoformação e a reabsorção. Como consequência da desarmonia, lacunas surgem em meio a superfície óssea, criando um ambiente favorável à proliferação de patógenos e ao acúmulo de fibras. Com a continuidade da sobrecarga e com a permanência dos microrganismos o suporte ósseo é comprometido, resultando na falha do implante. Em condições normais de carregamento, os implantes com conexão cônica possibilitam uma distribuição homogênea das tensões. O posicionamento da plataforma protética abaixo da crista óssea determina a transferência das tensões para áreas distantes ao osso cortical. O presente estudo utilizou a análise fotoelástica para avaliar a distribuição de tensão em modelos experimentais com implantes com conexão cônica instalados na posição equicristal, 1,5 mm infraósseo e 3,0 mm infraósseo. Foram propostas reabilitações com coroas protéticas unitárias em cerâmica, cimentadas em pilares protéticos sólidos e de parafuso passante com alturas de transmucoso de 1,5 mm, 3,0 mm e 4,5 mm. Os implantes foram posicionados na posição correspondente ao primeiro molar inferior direito. Segundo as situações adotadas, os conjuntos implante/pilar foram avaliados isoladamente, adjacentes a réplicas do segundo pré-molar inferior direito e do segundo molar inferior direito e apenas adjacentes a réplicas do segundo pré-molar inferior direito. A carga aplicada aos modelos fotoelásticos foi de 200 Ncm para todas as situações. Nos modelos com réplicas dentais foi realizado o carregamento oclusal distribuído, nos modelos com implantes isolados o carregamento foi pontual na fossa central e distal das coroas protéticas. Os resultados obtidos revelaram que a indicação de um pilar protético em detrimento a outro se configurou segundo a presença ou não de elemento dental posterior à coroa protética, assim como também por intermédio da profundidade da plataforma do implante na crista óssea remanescente. Em extremidades livres com implantes infraósseo a distribuição de tensão proporcionada pelo pilar de parafuso passante foi superior a do pilar sólido. Com a presença do segundo molar a distribuição da tensão foi mais eficiente com o pilar sólido, independentemente da profundidade da plataforma do implante. Nos modelos fotoelásticos com extremidade livre, o deslocamento da plataforma para uma posição infraóssea determinou menores tensões ao tecido ósseo. Havendo contatos proximais bilaterais a distribuição da tensão foi favorecida quando o implante ocupou a posição infraóssea a 3,0 mm, estando conectado ao pilar de parafuso passante. Entretanto, quando conectado ao pilar sólido o implante equicristal apresentou melhor distribuição de tensão que os implantes infraósseo. / Low-intensity stresses contribute to bone remodeling, while high intensity stresses cause bone resorption, below implant-abutment junction in dental implants. The occlusal overload affects the physiology of bone tissue, disrupting the balance between new formation and resorption. As a result of the disharmony, gaps arise in the crestal bone, creating a favorable environment for the proliferation of pathogens and fiber accumulation. With the continued overloading and the permanence of microorganisms, the bone support is impaired, resulting in implant failure. In normal loading conditions the tapered connection implants enables a homogeneous distribution of stresses. The subcrestal positioning of the prosthetic platform determines the transfer of stresses to distant areas from the cortical bone. This study used photoelastic analysis to evaluate the stress distribution in experimental models in conical abutment connection implants placed in equicristal position, 1.5 mm and 3.0 mm subcrestal positions. Rehabilitations were proposed for single prosthetic ceramic crowns cemented in standard and regular Ankylos prosthetic abutments with transmucosal height of 1.5 mm, 3.0 mm and 4.5 mm. Implants were placed in the position corresponding to the first lower right molar. According to the chosen situations, sets of implant/abutments were evaluated separately, adjacent to replicas of the second lower right premolar and second lower right molar and just adjacent to replicas of the second right premolar. The load applied to the photoelastic models was 200 Ncm in all cases. In models with dental replicas, distributed occlusal loading was performed; on models with isolated implant, loading was precise in the central and distal fossa of prosthetic crowns. The results showed that the indication of an abutment over another is depended on the presence or absence of a dental element posterior to the prosthetic crown, and of the implant platform depth of the remaining bone crest. In distal extension with subcrestal implants, stress distribution provided by Regular Ankylos prosthetic abutments was better than that provided by the Standard Ankylos abutment. With the presence of the second molar distribution of stress was more efficient with the Standard Ankylos abutment, regardless of the depth of the implant platform. In photoelastic models with distal extension, the platform displacement to a subcrestal position determined lower stress to the bone. Having bilateral proximal contacts, the stress distribution was favored when the implant was placed in a 3.0 mm subcrestal position with Regular Ankylos prosthetic abutments. However, when connected to the Standard Ankylos abutment, implant placed in equicristal position showed better stress distribution than subcrestal implants.
636

Avaliação da influência da pigmentação, opacificador e envelhecimento nas propriedades físicas e mecânicas de um silicone experimental para prótese bucomaxilofacial / Evaluation of the influence of pigmentation, opacifier and aging on physical and mechanical properties of an experimental silicone for maxillofacial prosthesis

Vomero, Marina Peris 29 January 2015 (has links)
O objetivo deste estudo foi propor a utilização de um novo silicone (Bio-Skin - BS) para prótese bucomaxilofacial. Foram analisadas alteração de cor, dureza Shore A, resistência à tração, características de superfície (MEV) e composição química (EDS) frente à diferentes pigmentações e envelhecimentos. Como parâmetro de comparação foi empregado o silicone MDX4-4210. Foram obtidos 120 espécimes para cada material com formato circular e 160 em forma de haltere, a partir de matrizes metálicas de corte, os quais foram distribuídos em 4 grupos: PI - pigmentação intrínseca (pó de maquiagem); OP - opacificador (sulfato de bário, BaSO4); PIO - associação de PI + OP; SP - sem adição de PI ou OP. Em seguida, os espécimes foram distribuídos aleatoriamente em 3 subgrupos para exposição ao envelhecimento por luz natural (LN, n=10), luz ultravioleta (UV, n=10) e ausência de luz (C, n=10). O período experimental foi de 12 meses. A alteração de cor foi verificada com auxílio de espectrocolorímetro e sistema CIE L*a*b*. Para a dureza foi utilizado um durômetro Shore A e a análise da resistência à tração foi realizada em máquina universal de ensaio. As variáveis de resposta quantitativas foram mensuradas imediatamente após a obtenção dos espécimes e após o período experimental. A análise de superfície foi realizada por microscopia eletrônica de varredura (MEV) e a composição química dos silicones, por espectroscopia por energia dispersiva (EDS). Os dados foram submetidos à análise de variância e teste complementar de Tukey (p<0,05). Os resultados das análises por MEV e EDS foram apresentados em imagens e gráficos. Houve interação entre todos os fatores (p<0,05) e ambos os materiais sofreram variações em função das pigmentações e envelhecimentos. Para alteração de cor, o silicone experimental (BS) apresentou as menores variações de cor. Analisando os silicones em função da pigmentação, o MDX apresentou maiores variações com os espécimes SP e com OP envelhecidos por luz natural e luz UV. Para o BS, houve alteração significativa da cor dos espécimes SP e OP somente após o envelhecimento por LN. Os dois materiais apresentaram aumento da dureza frente a todas as condições, sendo que o silicone BS apresentou a maior variação. O silicone experimental apresentou resistência à tração superior ao MDX em todas as situações. O MDX não sofreu influência significativa na resistência à tração por nenhuma das pigmentações ou envelhecimento, exceto quanto pigmentado com pó de maquiagem e envelhecido por UV, onde houve aumento da resistência. Quanto ao silicone BS, os maiores valores de resistência à tração foram encontrados com a PI e PIO em todos os grupos de envelhecimento. Pode-se considerar que o material experimental apresentou resultados favoráveis em relação à alteração de cor, dureza Shore A e resistência à tração para sua aplicação clínica em prótese bucomaxilofacial. A associação da pigmentação intrínseca, por meio de pó de maquiagem com opacificador, protegeu o silicone da alteração de cor e promoveu alterações aceitáveis nas propriedades mecânicas dos materiais. Todos os processos de envelhecimento promoveram alterações nas propriedades dos materiais. / The aim of this study was to propose the use of a new silicone (Bio-Skin - BS) for maxillofacial prosthesis. Color change, Shore A hardness, tensile strength, surface characteristics (SEM) and chemical composition (EDS) were analyzed, regarding different pigmentation and aging methods. The MDX4-4210 silicone was used as parameter of comparison. Specimens (120 circular and 160 dumbbell-shaped) were obtained for each material, from metal cutting molds, which were divided into 4 groups: IP - intrinsic pigmentation (makeup powder); OP - opacifier (barium sulfate, BaSO4); IPO - IP + OP association; WP - without adding IP or OP. Then, the specimens were randomly divided into 3 subgroups to aging by exposure to natural light (NL, n = 10), ultraviolet light (UV, n = 10) and without light (C, n = 10). The experimental period was 12 months. The color change was observed with spectrocolorimeter and CIE L*a*b* system. For hardness we used a Shore A durometer and the analysis of tensile strength was performed in a universal testing machine. The quantitative response variables were measured immediately after obtaining the specimens and after the experimental period. The surface analysis was performed by scanning electron microscopy (SEM) and the chemical composition of silicones, by energy dispersive spectroscopy (EDS). Data were submitted to ANOVA and Tukey\'s test (p <0.05). SEM and EDS results were presented in pictures and graphics. There was interaction between all factors (p <0.05) and both materials varied depending on the pigmentation and aging methods. For color change, the experimental silicone (BS) showed the lowest color variations. Analyzing the silicones due to the pigmentation, the MDX showed higher variation with the WP and OP specimens aged in natural light and UV light. For BS, there was significant change in the color of the WP and OP specimens only after aging for NL. The two materials presented an increase in hardness front of all conditions, and the BS silicone showed the greatest variation. The experimental silicone showed superior tensile strength to MDX in all situations. The MDX was not affected in tensile strength by any pigmentation or aging, except for the group pigmented with makeup powder and aged by UV, where there was an increase of resistance. As to BS silicone, the highest tensile strength values were found for the IP and IPO in all age groups. It can be considered that the experimental material showed favorable results regarding color change, Shore A hardness and tensile strength for clinical use in maxillofacial prosthesis. The association of intrinsic pigmentation through makeup powder and opacifier, protected silicone of color change and promoted acceptable changes in mechanical properties of the materials. All the aging processes promoted changes in material properties.
637

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Toledo, Fabiane Lopes 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
638

Análise pelo método de elementos finitos de um implante experimental para mandíbulas com reabsorção severa / Finite element analysis of an experimental implant for mandibles with severe resorption

Echevarría, Eduardo Andrés Borie 24 February 2016 (has links)
A reabsorção óssea mandibular severa é um problema, muitas vezes difícil de ser sanado, devido a largura e altura insuficientes de tecido ósseo, tornando impossível o emprego de implantes convencionais sem realizar qualquer tipo de procedimento para aumento ósseo. Várias técnicas para aumento de rebordo alveolar são empregadas, contudo podem apresentar alguns inconvenientes que dificultam o tratamento. Outra alternativa é a utilização de implantes curtos, mas a disponibilidade óssea pode limitar a utilização dos desenhos convencionais atuais. Assim, o objetivo deste estudo foi avaliar pelo método dos elementos finitos a distribuição de cargas em planejamentos com desenho experimental de implantes, em titânio e zircônia, posicionados na região pré foramen mental em mandíbulas com reabsorção severa e diferentes espessuras de cortical externa (1 e 2mm) e próteses totais fixas implantossuportadas. A mandíbula reabsorvida foi modelada com 12mm de altura, considerando o osso trabecular circundado por 2 mm de osso cortical e 1mm de cortical externa. Posteriormente, foi modelado um implante com geometria prismática e posicionado ao nível do osso, um em cada lado, na região interforaminal. Inicialmente, foi realizado um teste preliminar, simulando aplicação de forças axiais e oblíquas com diferentes direções em implantes de titânio e zircônia e osso cortical com 1mm e 2mm de espessura. Após adequação da geometria do implante, foram realizadas as simulações com as próteses confeccionadas em resina acrílica termopolimerizada apoiadas em uma barra com liga à base de Co-Cr. Foi empregada uma carga resultante dos quatro músculos principais da mastigação. Os implantes e pilares de titânio, e a barra protética foram analisados com tensão equivalente Von Mises, enquanto as tensões perimplantares no osso cortical, na região apical do osso trabecular e nos pilares e implantes de zircônia foram analisadas por tensões máximas e mínimas principais. O deslocamento foi fixado em valores mínimo e máximo para comparação do grau de movimentação entre os modelos. A análise foi realizada por meio da visualização gráfica do mapa de cores. O modelo de titânio com 1 mm de espessura de osso cortical apresentou o menor valor (13,27 MPa) de tensão máxima principal no osso, seguido pelo de 2mm (16,22 MPa) e pelos de zircônia de 1mm (16,94 MPa) e 2mm (18,43 MPa). Já os menores valores de tensão mínima foram evidenciados nos modelos com 1mm de osso cortical de titânio (-28,94 MPa) e zircônia (-33,30 MPa). Modelos com implantes de titânio e zircônia apresentaram valores iguais de deslocamento nas espessuras de 1mm (0,15mm) e 2mm (0,19mm). Pelos valores apresentados conclui-se que todos estão dentro nos limiares fisiológicos, com os implantes de titânio propiciando os menores valores de tensão. / Severe mandibular bone resorption is a problem, often difficult to be treated due insufficient width and height of bone tissue, making it impossible to use conventional implants without performing any procedure for bone augmentation. Several techniques for alveolar ridge augmentation are employed, but may present some drawbacks that hinder the treatment. Another alternative is the use of short implants, but the available bone can limit the use of current conventional designs. Thus, the aim of this study was to evaluate through finite element method the load distribution in plannings with an experimental design of implants, in titanium and zirconia, located in the pre-mental foramen region in mandibles with severe resorption and different external cortical thickness (1 and 2 mm) and complete implant-supported fixed dentures. The resorbed jaw was modeled with 12mm in height, considering the trabecular bone surrounded by an external cortical bone of 2 and 1mm. Subsequently, was modeled an implant with prismatic geometry and located at bone level, one on each side, between the mental foramen region. Initially, a preliminary test was performed simulating the application of axial and oblique forces with different directions over titanium and zirconia implants and with cortical bone thickness of 1mm and 2mm. After adjustment of implant geometry, analyses with prostheses made of heat-polymerized acrylic resin and supported on a Co-Cr framework were performed. It was employed a resultant load of the main four chewing muscles. The titanium implants and abutments and framework were analyzed through equivalent Von Mises stresses, while the stresses in the periimplant cortical bone, at apical region of the trabecular bone and the zirconia implants and abutments were analyzed through maximum and minimum principal stresses. Total deformation was set at minimum and maximum values to compare the degree of movement between the models. The analysis was performed through the graphical visualization of the color map. The model in titanium with 1mm-thick of cortical bone showed the lowest maximum principal stress value (13.27 MPa) at bone, followed by the 2mm-thickness (16.22 MPa) and the zirconia of 1 mm (16.94 MPa) and 2 mm (18.43 MPa). The lowest minimum stress values were observed in models with 1 mm of cortical bone in titanium (-28.94 MPa) and zirconia implants (- 33.30 MPa). Models with titanium and zirconia implants had equal total deformation values in thicknesses of 1mm (0.15 mm) and 2 mm (0.19 mm). By the observed values it may conclude that all models were within the physiological limits, with titanium implants providing the lowest stress values.
639

Próteses parciais fixas apoiadas sobre conexão dente-implante rígida: análise do comportamento biomecânico antes e após ciclagem mecânica / Tooth-implant supported rigid connected fixed partial dentures: Biomechanical behavior analysis before and after mechanical cycling

Rama, Glauber Macedo 10 September 2014 (has links)
A associação entre dente e implante em uma prótese parcial fixa (PPF) vêm sido questionada há muitos anos devido a suas implicações clínicas, incluindo a seleção do melhor tipo de união dos elementos protéticos (conexão rígida ou semi-rígida). Este estudo avaliou próteses dento-implanto-suportadas de conexão rígida do tipo cimentada sobre 3 tipos de conexão protética (hexágono externo - HE, hexágono interno - HI e cone morse - CM) e sua relação com o desajuste vertical e falhas na prótese antes e após ciclagem mecânica, além da análise fotoelástica destas situações. Foram confeccionados 21 corpos de prova (7 HE, 7 HI e 7 CM) sobre um modelo mestre que simulou a perda dentária dos elementos 46 e 47, sendo um implante posicionado na área do 47 e um dente preparado com ligamento periodontal simulado em poliéter na área do 45. Sobre este modelo foram confeccionadas PPFs metalocerâmicas de 3 elementos rígidas cimentadas sobre dente e implante (munhão universal). Os corpos de prova foram preparados e submetidos ao ensaio de ciclagem mecânica com uma carga de 120N por 1.000.000 de ciclos, simulando o uso clínico da prótese por 2 anos. Análises do desajuste vertical foram realizadas por meio de microscopia óptica (40x) em todos os períodos de confecção das PPFs (antes da solda, após solda, após aplicação da cerâmica e após ciclagem). O percentual de falhas nas próteses após ciclagem também foi avaliado (trincas/fraturas/decimentações), além da execução do ensaio fotoelástico (carga pontual dental, bipontual nos pilares e oclusal simultânea). Os resultados obtidos para o desajuste vertical indicaram um aumento significante dos níveis de desajuste para todas as etapas de confecção tanto para dente quanto implante (p<0,0001), porém não significante entre os grupos (p>0,059). Para o percentual de falhas na prótese, encontrou-se um índice decrescente na ordem CM>HI>HE. Para análise fotoelástica, encontrou-se um índice de concentração de tensões crescente na ordem CM&lt;HI&lt;HE. Baseado nos resultados encontrados, dentro das limitações do estudo foi possível concluir que: os níveis de desajuste vertical tendem a aumentar nas etapas de confecção da prótese para todas as conexões protéticas; a fadiga mecânica tende a interferir no grau de desajuste vertical a longo prazo pela deformação da estrutura a depender de sua espessura; o aumento no percentual de falhas da prótese tende a ser proporcional ao aumento da rigidez da conexão protética; apesar da redução da rigidez da conexão protética favorecer a longevidade da PPF, esta também tende a aumentar as tensões nos elementos pilares e stress no osso circundante; a utilização da conexão Morse subcrestal para união dente-implante rígida tende a ser preferível pela preservação dos elementos pilares devido a menor concentração de tensões em detrimento da longevidade da PPF, entretanto esta pode ser substituída caso a falha seja irreversível. / The association between tooth and implant in fixed partial dentures (FPD&prime;s) have been questioned for many years due to its clinical implications, including selecting the best kind of connection design (rigid or semi-rigid connection). This study assessed cemented toothimplant supported rigid connected FPD&prime;s on 3 types of implant connections (external hexagon - EH, internal hexagon - IH and morse taper - MT) and its relationship to the vertical misfit and FPD failure before and after mechanical cycling plus the photoelastic analysis of those situations. 21 specimens (7 EH, 7 IH and 7 MT) were fabricated on a master model that simulated tooth loss of elements 46 and 47, with an implant placed on the 47 area and a prepared tooth with simulated periodontal ligament in polyether on the 45 area. On this model, three-element metalloceramic rigid FPD&prime;s were made, cemented to tooth and implant (universal post). The specimens were prepared and subjected to mechanical cycling with a 120N load under 1,000,000 cycles, simulating a 2-year clinical use of the prosthesis. Analyses of vertical misfit were performed by optical microscopy (40x) in all periods of FPD&prime;s fabrication (before welding, after welding, after application of ceramic and after cycling). The FPD failure percentage after cycling was also evaluated (cracks/fractures/loss of cementation), and photoelastic test was performed (dental load only, simultaneous abutment load and occlusal load). The results for vertical misfit indicated a significant increase in the levels of misfit for all stages of fabrication for both tooth and implant (p<0.0001) but not significant between groups (p>0.059). For the FPD failure percentage, we found a decreasing rate in the order MT>IH>EH. The photoelastic test indicated a major amount of tension increase in the order MT&lt;IH&lt;EH. Based on these results, within the limitations of the study it was concluded that: the levels of vertical misfit tend to increase in the prosthesis fabrication steps for all implant connections; mechanical fatigue tends to interfere on vertical misfit in long term due to deformation of the framework depending on its thickness; the FPD failure percentage tends to be proportional to the rigidity increase of the implant connection; despite the decrease of rigidity of the implant connection favors the longevity of the FPD, this also tends to increase tensions on the abutments and stress on the surrounding bone; the use of subcrestal morse taper connection on rigid tooth-implant FPD&prime;s tends to be preferable for the preservation of the abutments due to the lower abutment stress concentration at the expense of longevity of FPD, though this can be replaced if the failure is irreversible.
640

Estudos eletroquímicos in vitro e in vivo da liga níquel–cromo–molibdênio– titânio aplicada em supraestruturas de implantes orais / In vitro and in vivo electrochemical studies of nickel-chromium-molybdenum-titanium alloy applied to oral implant suprastructures

Inada, Eduardo 21 October 2005 (has links)
Este trabalho avaliou o comportamento eletroquímico da liga de níquel-cromo-molibdênio- titânio em relação à liga ouro-platina-paládio em meio de NaCl 0,15 mol.L -1 a 36,5ºC. Os estudos in vitro também envolveram a caracterização eletroquímica do titânio, uma vez que as referidas ligas são empregadas em supraestruturas de implantes osseointegrados. Os estudos in vivo foram feitos com as ligas formando par com titânio comercialmente puro grau IV. Nos estudos in vitro, foram utilizadas técnicas de medidas de potencial de circuito aberto, curvas de polarização anódica e espectrofotometria de absorção atômica de chama. Os estudos in vivo foram interpretados utiliza ndo a microscopia eletrônica de varredura e a espectroscopia por dispersão de energia. A liga de ouro-platina-paládio e o titânio apresentaram resultados reprodutíveis. Suas superfícies são homogêneas e os valores de potencial de circuito aberto estacionário dos dois materiais diferem de menos de 100 mV. A permanência da liga ouro-platina-paládio junto do titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, a estabilidade da liga áurica e do titânio. A liga de níquel-cromo-molibdênio-titânio não apresentou reprodutibilidade nos resultados de potencial de circuito aberto e nas curvas de polarização anódica, apresentando uma faixa de pontencial muito reduzida de passividade, 100 mV. Na análise pela espectrofotometria de absorção atômica de chama, a liga ouro-platina-paládio apresentou pequena divergência com os dados fornecidos pelo fabricante, mostrando conter, além do ouro, platina e paládio, cerca de 1% de prata. A liga níquel-cromo-molibdênio-titânio, na análise pela espectrofotometria de absorção atômica, apresentou grandes divergências com os dados fornecidos pelo fabricante, fora da faixa de composição em que foi patenteada. Foi detectada a presença de alumínio em quantidade significativa, elemento não declarado pelo fabricante. O teor de níquel está acima da especificação, enquanto que o teor de titânio e de cromo se encontram abaixo. A análise por microscopia eletrônica de varredura com igual amplificação empregada para o estudo da liga áurica e do titânio, revelou que a liga níquel-cromo-molibdênio-titânio apresenta superfície heterogênea, caracterizada por quatro fases distintas: (fase 1 – rica em titânio; fase 2 – rica em níquel; fase 3 – rica em níquel e cromo; fase 4 – rica em molibdênio). A permanência da liga de níquel-cromo-molibdênio-titânio junto ao titânio, por seis meses no ambiente oral, mostrou por microscopia eletrônica de varredura, na análise por elétrons secundários, depressões na superfície da amostra na fase 2, sugerindo oxidação da fase rica em níquel, evidenciada pela presença de oxigênio superficial, quando comparada à mesma fase na superfície apenas polida. / The electrochemical behavior of the nickel-chromium-molybdenum-titanium (Ni-Cr-Mo-Ti) alloy was studied and compared to a gold-platinum-palladium (Au-Pt-Pd) alloy in 0.15 mol.L -1 NaCl medium at 36.5ºC. In vitro studies also involved the electrochemical titanium characterization since these alloys are employed in osseointegrated implant suprastructures. In vivo studies were made using alloy-titanium (Ti cp) couples. Open circuit potential (OCP) measurements, anodic polarization curves (APC) and flame atomic absortion spectrophotometry (FAAS) were used as techniques in in vitro experiments. Scanning electronic microscopy (SEM) and energy dispersion spectroscopy (EDS) were used in order to interpret in vivo experiments. The Au-Pt-Pd alloy and Ti showed reproducible results. Their surfaces are homogeneous and the stationary OCP values of the two materials differ by a value less than 100 mV. The permanence of Au-Pt-Pd alloy near titanium for six months in oral environment showed by SEM the stability of the two materials. The Ni-Cr- Mo-Ti alloy did not show reproducibility in OCP and APC results, exhibiting narrow potential range of passivity about 100 mV. The Au-Pt-Pd alloy, under FAAS analysis, presented some divergence in the chemical composition when compared to that one previously provided by the manufacturer. FAAS detected 1% weight of silver. The Ni-Cr-Mo-Ti alloy, however, presented significant divergences and a chemical composition different from that one corresponding to the patent. The presence of aluminum not declared by the manufacturer was detected in meaningful amounts. SEM analysis of Ni-Cr-Mo-Ti alloy with the same amplification used for Au-Pt- Pd alloy and Ti showed a heterogeneous surface characterized by four phases: phase 1 – rich in titanium; phase 2 – rich in nickel; phase 3 – rich in nickel and chromium; phase 4 – rich in molybdenum. The permanence of Ni-Cr-Mo-Ti alloy,for six months in oral environment, showed by SEM using secondary electrons, depressions on the phase 2 area, suggesting oxidation of the rich nickel phase, with a significant oxygen presence, when compared to the correspondent area on the polishing surface.

Page generated in 0.1006 seconds