• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 534
  • 269
  • 39
  • 39
  • 23
  • 17
  • 17
  • 17
  • 17
  • 16
  • 11
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 1029
  • 457
  • 319
  • 246
  • 131
  • 126
  • 125
  • 115
  • 95
  • 89
  • 84
  • 81
  • 75
  • 73
  • 69
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
661

Desenvolvimento de prótese auditiva retroauricular, digital e de especificações mínimas / Development of digital behind-the-ear hearing aid with minimal specifications

Silvio Pires Penteado 31 August 2009 (has links)
A International Federation of Oto-Rhino-Laryngological Societes (IFOS) estima que cerca de 10% da população americana seja portadora de algum tipo de perda auditiva. O Better Hearing Institute afirma que nos Estados Unidos cerca de 31 milhões de pessoas apresentam algum tipo de perda auditiva, ou cerca de 10% de sua população. Muitas são as causas que contribuem para o aumento do contingente de deficientes auditivos, dentre os quais a presbiacusia, as doenças hereditárias, doenças metabólicas, uso de drogas ototóxicas, traumas acústicos, excesso de ruído, neoplasias, infecções e danos vasculares e causas idiopáticas. Dentre os efeitos perniciosos da perda auditiva estão a frustração, insegurança, paranóia, tensão, nervosismo, irritabilidade, instabilidade, medo, sensação de inferioridade, sensação de confusão, descontentamento, fobia social e depressão. Crianças com perdas auditivas unilaterais tendem a apresentar baixos níveis de aproveitamentos escolares, a demandar por técnicas especiais de linguagem por conta dos efeitos permanentes da incapacidade de cognição, mesmo quando se tratava de perdas auditivas leves. Pelo prisma da audiologia clínica todo portador de deficiência auditiva pode ser considerado um candidato ao uso de prótese auditiva - ou aparelho auditivo - um dispositivo eletrônico cujos componentes principais - processador digital de sinais, microfone e receptor - podem ser adquiridos da cadeia de suprimentos que abastecem os fabricantes internacionais que dominam o mercado mundial. Estes fabricantes procuram ofertar produtos com uma maior densidade de recursos tecnológicos que os seus concorrentes em paga de lucros maiores, a oferecer mais que os clientes necessitam ou estão dispostos a pagar. Estas organizações internacionais trazem produtos cujos preços finais são incompatíveis para os cidadãos de países em desenvolvimento. Um dos objetivos deste estudo é o de entender o modelo de negócios praticado pela indústria de próteses auditivas, notavelmente a prática de varejo, a mais lucrativa. O outro objetivo é o de desenvolver uma prótese auditiva no desenho retroauricular, digital e de especificações mínimas, que possa competir com aquelas fornecidas por organizações lv internacionais para a condução das políticas públicas, segundo a Portaria 587, Anexo IV do Ministério da Saúde. Foi contatada a cadeia de suprimentos destas organizações, solicitadas amostras diversas e montados protótipos funcionais, que depois de vários ensaios permitiram a definição de uma arquitetura eletroeletrônica básica. Esta arquitetura foi novamente ensaiada, tendo como resultado um configuração eletroeletrônica final, a qual definiu uma prótese no desenho retroauricular. De modo a definir os recursos tecnológicos e as especificações eletroacústicas do produto final para o atendimento das especificações do Ministério da Saúde, foram utilizadas as ferramentas de engenharia do fabricante do componente principal (processador digital de sinais), que incluíam o desenvolvimento com base no servidor do fabricante (online), desenvolvimento com auxílio de programas específicos (stand alone), montagem eletroeletrônica e mecânica para finalmente certificar o produto final com a mesma norma internacional das próteses auditivas comercializadas no mercado nacional. Foi possível entender o modelo de negócios praticado na indústria de próteses auditivas com a identificação dos principais atores e como se relacionam. A única prótese auditiva desenvolvida no desenho retroauricular atende a todos os requisitos de Tecnologia A e B, o que corresponde a 85% da demanda das aquisições do Governo Federal. / The International Federation of Oto-Rhino-Laryngological Societies (IFOS) estimates as 10% the total amount of hearing impaired in United States. The Better Hearing Institute asserts that in United States about 31 million people have hearing losses in some degree, say around 10% of total population. Increasing the amount of hearing-impaired there is a list of causes as presbyacusis, hereditary diseases, metabolic diseases, use of ototoxic drugs, acoustic trauma, noise-induced, neoplasia, infections and vascular damages and idiopathic causes. Amongst of perverse effects of hearing losses are frustration, insecurity, paranoia, tension, nervousness, irritability, instability, fearful, sense of inferiority, sense of confusion, discontentment, social phobia and depression. Children with unilateral hearing loss appear to show high grade failures, demands for additional assistance due to permanent effects of cognition inability, even so when they are affected by mild hearing losses. By means of Audiology perspective all hearing impaired are normal applicant to wear a hearing aid, an electronic device whose chief components - digital signal processing, microphone and receiver - can be acquired from the international manufacturers supply chain, whose rule the world market. These manufacturers push products to market with higher density of technological resources than their competitors in exchange of higher profits, to offer more than the customers need or are willing to pay for. Those international organizations bring products which end prices are unmatched to citizen in the developing countries. One of the objectives of the present study is to understand the business model these organizations run, mainly the most profitable one: retail business. The other objective means the developing the digital behind-the-ear hearing aid with minimal specifications, to compete with those hearing aids, same design, supplied by these organizations to the Brazilian Government for its open tender, according to Government directive 587, section sign IV of Health Minister. It was contacted these organizations supply chain, requested samples and assembled some functional prototypes, whose after some experiments lead us to determine a basic electroelectronic architecture. This architecture was submitted to more experiments until final lvii electroelectronic architecture was determined and it was rested inside a behind-the-ear case. To determine end product technological resources and the electroacoustic specifications to fulfill Health Minister specifications it was managed engineering tools of the main component (digital signal processing), which entails being logon on the manufacturer server, also stand alone on a personal computer, to assemble the electro-electronic and mechanical modules to submit the end product to the same international standard the hearing aids already traded in the Brazilian market place. It was possible the understanding the current business model also to identify the main actors and how they interact each other. The only digital behind-the-ear hearing aid developed complies with all requirements labeled as Technology A and B, respective of 85% of all Brazilian Government acquisitions.
662

Laringectomizados Usuários de Prótese Traqueoesofágica:Princípios e Métodos da Prática Fonoaudiológica

Ghirardi, Ana Carolina de Assis Moura 13 February 2007 (has links)
Made available in DSpace on 2016-04-27T18:12:18Z (GMT). No. of bitstreams: 1 Ana Carolina de Assis Moura Ghirardi.pdf: 819639 bytes, checksum: 6d8ec430913ecbd61df4bd90523f8c8c (MD5) Previous issue date: 2007-02-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of the present study is to analyze the principles and methods present in Speech Therapy of totally laryngectomized patients who use a tracheoesophageal prosthesis. Methods: The participants of the study were three speech therapists with experience in the field of laryngectomy rehabilitation, three head and neck surgeons and three patients using a vocal prosthesis for a minimum period of one year. The subjects were divided into three separate groups, according to their role in the study: Speech therapists (GF), head and neck surgeons (GM) and patients (GU). The speech therapists were submitted to an open interview, in which they assessed their clinical practice with such patients, in detailed manner. After reading the material collected from these interviews, a questionnaire was developed so that the surgeons could consider their expectations towards speech therapy as well as their ideas on clinical success. Likewise, a third questionnaire was developed, targeting the patients views on speech therapy, their recollections on the subject and their references to specific clinical strategies. After all interviews and questionnaires were collected, the material was thoroughly read several times, and the content was organized in different categories which derived from the contents of subjects speech. Speech order was maintained while organizing the categories. Thus, the data analysis was done considering each group separately, since not all categories were the same for the three groups. However, a comparison was made for all groups, with regards to those categories that matched in all three. Results: The time span of therapy was considered small by GF. The most common techniques described by the speech therapists were those aiming stoma occlusion, coordination between occlusion, breathing and speech, speech intelligibility and pitch and loudness modulations. For this group, the main objective of speech therapy is to ensure that the vocal prosthesis is the main way of alaryngeal communication, if the patient so desires. For GM, the main role of speech therapy is to provide vocal expression resources so that the patient can achieve communicative independence. They also feel that speech therapy should be a space where the patients learn to master their prosthesis resources and learn how to care for it effectively. As for GU, the main gain related to speech therapy was improvement in quality of life, due to the re-gaining of speech and voice, leading to greater social interaction. All viewed their time with the speech therapist as a positive one, and do not necessarily consider a short time-span as a main advantage of the tracheoesophageal prosthesis. As a result of the combined analysis, the principles of speech therapy with these patients are: to insure the patients adjustment to their prosthesis, to present them with specific speech techniques and to promote conditions where the patient is free to express himself and thus expand the abilities acquired in therapy to his daily life activities. Conclusions: Therefore, the main goal of speech therapy is a combination of the aspects pointed out by members of the three groups; that is, to provide the patient with independence to handle and use his prosthesis not only in a daily manner, but with mastery of all its resources and expression possibilities, but to promote as well a greater social interaction of these people with their peers, hence improving their overall quality of life / Objetivo: Analisar os princípios e métodos presentes na terapia fonoaudiológica de pacientes laringectomizados totais usuários de prótese traqueoesofágica, do ponto de vista de fonoaudiólogos, médicos e pacientes. Métodos: Os participantes da pesquisa foram três fonoaudiólogas que atuam na área de reabilitação de laringectomizados totais (GF), três médicos cirurgiões de cabeça e pescoço (GM) e três usuários de prótese traqueoesofágica (GU). Os fonoaudiólogos responderam a uma entrevista contendo uma pergunta de caráter aberto, sobre a sua prática na reabilitação desses pacientes. A partir da leitura do material coletado, elaborou-se um questionário para GM, sobre suas expectativas quanto ao processo terapêutico fonoaudiológico, e outro para GU, que versava sobre técnicas específicas, expectativas e lembranças do processo de terapia fonoaudiológica. Após a leitura do material, foram elaborados mapas de associação de idéias, e as falas dos entrevistados foram alocadas em categorias correspondentes. Dessa forma a análise foi realizada de forma individual para cada grupo. Em um segundo momento, as falas dos entrevistados dos três grupos foram comparadas entre si, com base nas categorias elaboradas. Resultados: O trabalho com os usuários de prótese traqueoesofágica é descrito pelas fonoaudiólogas como rápido. A atuação no período pré-operatório consiste de orientações acerca da cirurgia e suas implicações e sobre os métodos alternativos de comunicação disponíveis. Após a cirurgia, a terapia fonoaudiológica consiste, predominantemente, de técnicas específicas para oclusão do estoma, coordenação entre expiração e fonação, fluência de fala, tempo máximo fonatório, e variação de altura e intensidade vocal. O caso é considerado bem sucedido quando o paciente utiliza a prótese como principal forma de comunicação. Para os médicos, a função da terapia fonoaudiológica é dar ao sujeito autonomia de comunicação, por meio de recursos expressivos e domínio do uso da prótese. Para os usuários, o contato com a fonoaudióloga foi positivo e os principais ganhos foram em qualidade de vida, pela re-integração social e retomada da fala. Assim, os princípios da atuação fonoaudiológica foram: mediar a adaptação do paciente à PTE, oferecer técnicas para a fonação e propiciar condições para que ele se expresse. Considerações Finais: Observa-se que a função do fonoaudiólogo é a combinação entre as expectativas dos três grupos: propiciar ao paciente um domínio da prótese por meio da expressão, autonomia no cuidado com a mesma, fazendo com que esse seja seu principal recurso de comunicação. Dessa forma, a melhora da qualidade de vida, pela reintegração na sociedade passa a ser o principal objetivo da atuação com laringectomizados
663

Acionamento e controle de um dedo de uma prótese para membro superior com realimentação proprioceptiva de força e temperatura

Del Cura, Vanderlei de Oliveira 14 June 2005 (has links)
Este trabalho visa contribuir para redução do grau de rejeição de próteses para membros superiores, tornando-as mais funcionais e eficientes. Tais propósitos são almejados por meio do estudo centrado no desenvolvimento de uma plataforma eletrônica de controle e nos demais constituintes de uma prótese. Dentre eles estão os atuadores, sensores, mecanismos e o programa de gerenciamento, que integra todos os componentes para as ações da prótese. Para esse trabalho foi usado somente um dedo para a execução de todos os testes, sendo esse dedo compatível com o desenvolvimento de uma prótese antropomórfica multifunção. O paciente comanda as ações da prótese ao enviar suas decisões à ela por meio de sinal mioelétrico, mas as ações da mesma são executadas de forma inconsciente. Isto é possível devido ao programa de gerenciamento, que controla os movimentos antropomórficos a partir de trajetórias definidas e também pelas informações de sensações de força e temperatura para o paciente, realimentação proprioceptiva. / This work contributes to minimize the rejection level of upper limb prosthesis, keeping it more function and efficient. This achieved by the development of a control electronic platform and the others prosthesis components, like actuators, sensors, mechanisms and the management program, that integrate all the components to actions of prosthesis. In this work was used only one finger to perform of all tests, and this finger is compatible with the development of a multifunction anthropomorphic prosthesis. The user command comes from myoelectric signal, but the actions in the prosthesis are executed unconsciously. The management program control the anthropomorphic movements based on defined trajectory and create information of force and temperature sensation to the user, proprioceptive feedback.
664

Implante experimental de substituto arterial de polidimetilsiloxano com reforço de tecido de poliéster em coelhos / Experimental implant of arterial substitute of polydimethylsiloxane reinforced with polyester fabric in rabbits

Ribas, Laila Massad 21 August 2013 (has links)
O presente estudo avaliou próteses vasculares de pequeno calibre feitas de polidimetilsiloxano (PDMS) com reforço de poliéster implantadas em aorta de coelhos através de fluoroscopia. Os objetivos do estudo foram: (1) analisar tubo de PDMS com reforço de poliéster implantado em aorta de coelhos como possível material para prótese vascular, (2) avaliar a patência das próteses através de fluoroscopia, (3) avaliar a condição de implante cirúrgico; (4) avaliar o comportamento macroscópico biológico do implante e (5) analisar o modelo experimental proposto. Próteses vasculares de PDMS foram implantadas na aorta infrarrenal de 64 coelhos cedidos pelo biotério da Faculdade de Medicina da Univesidade de São Paulo. Os exames de fluoroscopia foram realizados em até 150 dias após implantação cirúrgica. As próteses de PDMS foram classificadas em ocluídas e patentes, sendo essas sub-classificadas em diferentes graus de estenose. O tempo de clampeamento da aorta foi aferido durante os procedimentos cirúrgicos. De maneira amostral peças foram encaminhadas para microscopia eletrônica para verificação de endotelização das próteses. As análises estatísticas foram feitas através de teste t-Studant, teste ANOVA e Kaplan-Meier. Dos 64 animais que receberam a prótese, trinta (46,88%) apresentaram boa evolução clínica, vinte e três (35,94%) morreram e onze (17,18%) apresentaram paraplegia de membros posteriores. A patência das próteses em 30 dias foi de 87% (±6,7), em 60 dias foi de 73% (±9,3), em 90 dias foi de 57% (±11) e em 120 dias foi de 48% (±12). Cinquenta por cento (oito) das próteses patente não apresentaram nenhum grau de estenose, 35,5% (seis) apresentaram cinquenta por cento ou menos de estenose e 12,5% (dois) apresentaram estenose entre cinquenta e setenta por cento. Nenhum animal apresentou estenose maior que 70%. O tempo médio de clampeamento da aorta foi de 52 minutos. Não houve diferença significante nem na associação entre tempo de clampeamento da aorta e a evolução clínica dos animais (p=0,67) nem na associação entre o tempo de clampeamento e a patência das próteses (t=1,35; p=0,18). As peças encaminhadas para microscopia apresentaram crescimento endotelial a partir do vaso nativo em direção à prótese de PDMS. Foi possível concluir com este estudo que o PDMS demonstrou-se um material adequado para futuras pesquisas no ramo de próteses vasculares e que o uso da fluoroscopia na avaliação dessas próteses foi de fundamental importância na determinação da patência dos implantes / The present study evaluated small caliber vascular prostheses made of polydimethylsiloxane (PDMS) with polyester reinforcement implanted in the aorta of rabbits by fluoroscopy. The study objectives were: (1) analyze PDMS tube with polyester reinforcement implanted in the aorta of rabbits as possible material for vascular prosthesis, (2) assess the patency of the prosthesis through fluoroscopy, (3) assess the condition of surgical implant (4) evaluate the macroscopic behavior of biological implant and (5) analyze the proposed experimental model. Vascular prostheses were implanted in PDMS infrarenal aorta of 64 rabbits assigned by the animal house of the Faculty of Medicine of the University of São Paulo. Fluoroscopic examinations were performed within 150 days after surgical implantation. The prosthesis of PDMS were classified into occluded and patents, these being sub-classified into different degrees of stenosis. The time of aortic clamping was measured during surgical procedures. Sample pieces were sent for electron microscopy to check endothelialization of prostheses. Statistical analyzes were performed using t-test Studant, ANOVA and Kaplan-Meier. Of the 64 animals that received the prosthesis, thirty (46.88%) showed clinical improvement, twenty-three (35.94%) died and eleven (17.18%) had paraplegia of hind limbs. The patency of the prosthesis in 30 days was 87% (± 6.7), at 60 days was 73% (± 9.3), at 90 days was 57% (± 11) and at 120 days was 48 % (± 12). Fifty percent (eight) of the prosthesis patent did not present any degree of stenosis, 35.5% (six) had fifty percent or less of stenosis and 12.5% (two) had stenosis between fifty and seventy percent. No animal showed stenosis greater than 70%. The mean aortic clamping was 52 minutes. There was no significant difference in the association between duration of aortic clamping and clinical evolution of animals (p = 0.67) nor the association between clamping time and patency of the prosthesis (t = 1.35, p = 0.18). The parts sent for microscopy showed endothelial growth from the native vessel toward the prosthesis PDMS. It can be concluded from this study that the PDMS proved to be a suitable material for future research in the field of vascular prostheses and the use of fluoroscopy in the evaluation of these prostheses was of fundamental importance in determining the patency of the implants
665

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Tiossi, Rodrigo 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92μm), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10μm e Ti cp: 48,41 ± 26,69μm). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76μm, Ni-Cr: 20,13 ± 7,97μm, e Ti cp: 22,28 ± 17,29μm, e no lado contrário: Co-Cr: 118,64 ± 91,48μm, Ni-Cr: 70,66 ± 20,88μm, e Ti cp: 118,56 ± 51,35μm. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08μm). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81μm) e Ti cp (17,70 ± 11,70μm), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36μm) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15μm) e em Ti cp (40,42 ± 27,14μm) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67μm, após a simulação, quando era 41,02 ± 26,15μm após soldagem a laser para o primeiro e, 40,42 ± 27,14μm e 28,05 ± 20,89μm, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92μm), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10μm e Cp Ti: 48.41 ± 26.69μm). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76μm, Ni-Cr: 20.13 ± 7.97μm, and Cp Ti: 22.28 ± 17.29μm, and on the opposite side: Co-Cr: 118.64 ± 91.48μm, Ni-Cr: 70.66 ± 20.88μm, and Cp Ti: 118.56 ± 51.35μm. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08μm). For the other two groups, Ni-Cr alloy (13.10 ± 1.81μm) and Cp Ti (17.70 ± 11.70μm), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36μm) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15μm) and the Cp Ti (40.42 ± 27.14μm) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67μm, after simulation, when was 41.02 ± 26.15μm after laser welding for the first and, 40.42 ± 27.14μm and 28.05 ± 20.89μm, before and after, for the second, though not showing any statistically significant differences.
666

Avaliação da posição do modelo auricular virtual gerado por imagem captada com escâner a laser e desenvolvimento de dispositivo posicionador 3D / Evaluation of the position of the virtual auricular model generated by image captured by laser scanning and development of 3D positioner device

Marafon, Priscila Galzo 13 March 2013 (has links)
Este trabalho fundamenta a aquisição de modelo digital auricular por meio do escâner de superfície e avalia o posicionamento tridimensional do modelo auricular digital, espelhado segundo medidas antropométricas faciais, com e sem referência anatômica do canal auditivo externo, bem como desenvolve um dispositivo posicionador tridimensional para prótese auricular. Os dados de dez indivíduos voluntários, adultos maiores de 25 anos de idade, não portadores de lesão congênita ou adquirida na região craniofacial e de ambos os gêneros foram submetidos ao Teste dos Postos Sinalizados de Wilcoxon (p0,05) e a medida angular C6 foi avaliada de forma porcentual. Os resultados demonstram que ocorre assimetria nas medidas lineares da posição dos modelos auriculares direitos e esquerdos espelhados nos respectivos lados contralaterais da face sem a referência do conduto auditivo externo, sendo duas vezes mais frequente no espelhamento do modelo auricular esquerdo no lado direito da face. Observa-se menor assimetria dos modelos auriculares direitos espelhados no lado esquerdo da face e simetria na posição dos modelos esquerdos espelhados no lado direito da face, com a referência do conduto auditivo externo. A medida angular C6 apresenta menor assimetria na posição dos modelos auriculares direitos do que nos esquerdos, espelhados nos respectivos lados contralaterais da face, com e sem a referência do conduto auditivo externo. Conclui-se que a utilização do conduto auditivo externo como referência anatômica proporciona melhor simetria linear e angular da posição dos modelos auriculares virtuais direitos e esquerdos, espelhados nos respectivos lados contralaterais da face. O dispositivo posicionador projetado possibilita o ajuste das assimetrias detectadas no espelhamento de modelos auriculares, promovendo a compensação das discrepâncias evidenciadas durante o planejamento virtual para posicionamento do modelo auricular. / This study substantiates the acquisition of auricular digital model, by means of surface scanner, and assesses the placement of three-dimensional auricular digital models, mirrored according to facial anthropometric measurements, with and without anatomical reference of the external auditory canal, as well as developing a prosthetic device for three-dimensional positioning of the mirrored auricular model. The digital data of ten volunteers, adults over 25 years old, not suffering from congenital or acquired lesions in the craniofacial region and of both genders underwent Wilcoxon Ranking Test (p0.05) and angular measurement C6 was assessed as percentage. The results show that occurs asymmetry regarding the linear measurements in the positioning of the right and left ear models when mirrored in their contra lateral side of the face without reference of the external auditory canal, being twice as common in mirroring the left auricular model on the right side of the face. It is observed less asymmetry in the right auricular models mirrored on the left side of the face and symmetry in the positioning of the left models mirrored on the right side of the face, with the reference of the external auditory canal. The angular measurement C6 shows less asymmetry in the positioning of the models right auricular model than in those of the left, mirrored in their contra lateral side of the face, with or without reference to the external auditory canal. The use of the external auditory canal as anatomical reference provides better linear and angular symmetry in positioning the virtual auricular right and left models, mirrored in their contra lateral side of the face The three-dimensional positioner device designed enables the adjustment of the asymmetries found in mirroring the digital auricular models, providing compensation for discrepancies evidenced during the virtual positioning of the auricular model.
667

Influência da inclinação das cúspides, tipo de retenção e envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas sobre implantes / Influence of cusp inclination, type of retention and mechanical aging on fracture strenght of the implant-supported metal-ceramics crowns

Rocha, Cibele Oliveira de Melo [UNESP] 31 July 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-31. Added 1 bitstream(s) on 2017-03-14T14:42:44Z : No. of bitstreams: 1 000874660.pdf: 1969189 bytes, checksum: 5bdc581e4bd9de3fcf1b285eb40d888b (MD5) / O objetivo do estudo foi avaliar a influência da inclinação das cúspides, do tipo de retenção e do envelhecimento mecânico na resistência à fratura de coroas metalocerâmicas implanto-suportadas. Para o ensaio estático utilizou-se seis grupos (n=10): coroas cimentadas com cúspide de inclinação padrão (CIP) de 33º ou cúspides de inclinação reduzida (CIR) de 20°, parafusadas com o orifício de acesso ao parafuso (OAP) não-restaurado com CIP ou CIR e parafusadas com OAP restaurado com CIP ou CIR. Para o efeito do envelhecimento, 4 grupos foram utilizados (n=20): cimentadas com CIP ou CIR; e parafusadas com OAP não-restaurado com CIP ou CIR, em que 50 % das amostras de cada grupo foram cicladas mecanicamente previamente ao ensaio estático. Coroas de um segundo molar inferior foram confeccionadas sobre análogos de implante hexágono externo 5.0 (Biomet 3i, West Palm Beach, FL). O ensaio estático foi realizado aplicando-se força até a fratura da porcelana e para o efeito do envelhecimento, a ciclagem foi realizada (1 x 106; 125 N; 10Hz) antes do ensaio de resistência máxima à fratura. Após análise estatística observou-se que as médias de resistência à fratura apresentaram efeito significativo para Forma de Retenção (FR) e Inclinação de cúspide (IC) (p<0,01). Para FR apenas as coroas parafusadas não apresentaram diferenças estatísticas entre si (p>0,05), porém ambas apresentaram valores estatisticamente menores do que as cimentadas. Para IC, CIP apresentaram menores valores de resistência à fratura. Após o envelhecimento mecânico foi observado efeito significativo somente para os fatores isolados Forma de Retenção e Inclinação de cúspide (p<0,01), com melhores resultados para coroas cimentadas e CIR, respectivamente. O fator Envelhecimento Mecânico (p=0,659) não apresentou efeito significativo. Diante dos resultados, conclui-se que isoladamente... (Resumo completo, clicar acesso eletrônica abaixo) / The aim of this study was evaluate the influence of cusp inclination, type of retention and mechanical aging on fracture strength of implant-supported metal-ceramic (MC) single crowns. To static test, six groups were used (n=10): cemented crowns with 33° standard cusp inclination (SCI) or with 20° reduced cusp inclination (RCI), screwed crowns with screw access hole (SAH) not restored with SCI or RCI and screwed crowns with SAH restored with SCI or RCI. To test aging effect, 4 groups were used (n=20): cemented with SCI or RCI; and screw-retained with SAH not restored with SCI or RCI, in which 50% of specimens of each group were submitted to mechanical aging previously to static test. Crowns of a lower second molar were made on the analog implant external hexagon 5.0 (Biomet 3i, West Palm Beach, FL). The cycling (1.106; 125N; 10Hz) will be performed before the fracture resistance test. The static test was performed in a universal testing machine EMIC DL2000, with load application until porcelain failure. After statistical analysis it was observed that the mean fracture resistance of porcelain showed significant effect (p<0.01), to type of retention (TR) and cusp inclination (CI), respectively. To TR, screwed crowns did not show statistical differences (p>0.05), however, both two showed statistically lower values than cemented. To CI, crowns with SCI showed lower values of fracture resistance. After mechanical aging, TR and CI showed significant effect (p<0.01), with better results to cemented crowns and RCI, respectively. The factor mechanical aging did not show significant effect (p=0.659). According to these results, it was concluded that alone, type of retention and the cusp inclination showed influence on fracture resistance of MC crowns, being cemented crowns and reduced cusps mechanically more resistant against a static and cyclic load. The mechanical aging had no significant... (Complete abstract electronic access below)
668

Avaliação comparativa da influência do tratamento superficial e do agente cimentante na retenção de núcleos metálicos fundidos em titânio c.p. / Comparative evaluation of the influence of superficial treatment and luting agent to the tensile strength of titanium cast post and cores

Luiz Ricardo Menani 21 December 2005 (has links)
O uso de núcleos metálicos fundidos é comum na Odontologia Restauradora para promover a substituição de estruturas perdidas em dentes tratados endodonticamente. Estes núcleos podem ser fundidos em ligas nobres ou ligas básicas: as ligas alternativas apresentam vantagens mas são susceptíveis à corrosão. O titânio foi introduzido na Odontologia com o objetivo de compensar as deficiências dos metais básicos, principalmente a corrosão e seus produtos. Então, a proposta deste estudo foi comparar a resistência à tração de núcleos metálicos fundidos confeccionados em liga de ouro tipo III, titânio e titânio tratado superficialmente com solução de Kroll quando fixados com diferentes agentes cimentantes. Quarenta e dois caninos humanos extraídos foram selecionados, a porção coronária foi removida e a raiz remanescente foi tratada endodonticamente. Todos os espécimes foram divididos em seis grupos (n=7). O espaço para pino foi preparado a uma profundidade de 10mm usando-se brocas de Largo. Os núcleos foram fundidos em liga de ouro tipo III e titânio c.p. e fixados com cimento de fosfato de zinco ou cimento resinoso (Panavia F). A resistência à tração foi determinada em uma máquina universal de ensaios a uma velocidade de 0,5mm/min utilizando-se uma célula de carga de 50 Kgf. Os resultados foram analisados estatisticamente por ANOVA, demonstrando que não houve diferença estatisticamente significante entre os grupos. Dentro das limitações deste estudo pode-se concluir que os núcleos metálicos fundidos em titânio c.p. fixados com cimento fosfato de zinco ou cimento resinoso são uma alternativa viável aos núcleos metálicos fundidos em ouro. / The use of cast post and core is common in restorative dentistry to provide long-term tooth structure replacement for endodontically treated teeth. They could be cast in precious or basic alloys: the alternative alloys present advantages but they are susceptible to corrosion and its effects. The titanium was introduced to Dentistry with the objective of compensating the metal basic deficiencies, mainly the corrosion. Then, the purpose of this study was to compare the tensile resistance among gold alloy, titanium, and titanium after a superficial treatment with Kroll’s solution when fixed with different luting agents. Forty two human extracted canines were selected, the coronal aspect of each tooth was removed and the remaining root received endodontic therapy. All specimen were divided into six groups (n=7). The post space was prepared at a depth of 10mm using a Largo’s drill. The cast post and core were manufactured using a type III gold alloy and titanium. Cast post and core were fixed with zinc phosphate or resin luting agent (Panavia F). Tensile bond strength of the specimens was measured with a universal testing machine at a crosshead speed of 0,5mm/min and cell-load of 50 Kgf. Data (Kgf) were statistically analyzed by ANOVA. The results demonstrated that there was not a significant difference among the groups. Within the limitations of this study it has been conclude that the titanium fixed with zinc phosphate or resin luting agent is a viable alternative to the gold alloy to fabricate cast post and cores.
669

"Estudo do comportamento mecânico de protetores bucais confeccionados em copolímero de etileno e acetato de vinila: modelo experimental de arcos dentais obtidos em epóxi" / Study of the mechanical behaviour of mouth protectors prepared with ethylene and vinyl acetate copolymer: experimental model of dental arches produced with epoxy

Coto, Neide Pena 24 March 2006 (has links)
Um modelo experimental de arco dentário, moldado em epóxi, foi utilizado para estudar o comportamento mecânico do copolímero de etileno e acetato de vinila (EVA), na forma de placa plana e protetor bucal. O modelo experimental foi investigado, usando-se um sistema configurado em duas formas diferentes: suporte + arco + placa plana e suporte + arco + protetor bucal. O comportamento mecânico do copolímero de etileno e acetato de vinila foi estudado em função de três variáveis: espessura, temperatura e na ausência e presença de saliva artificial. A avaliação do comportamento mecânico do EVA, na forma de placa e protetor, foi feita usando-se dois planejamentos estatísticos fatoriais, 3x2x2 e 23, respectivamente, numa máquina universal de tração. As propriedades mecânicas do EVA, ao esforço compressivo, avaliadas nas duas configurações (suporte + arco + placa e suporte + arco + protetor) foram: energia aparente absorvida (J.mm-1), tensão máxima (N.mm-1), deslocamento máximo (mm) e força máxima (N). Os efeitos das variáveis, espessura, temperatura e presença ou ausência da saliva artificial foram modelados, matematicamente, usando-se as propriedades mecânicas do EVA ao esforço compressivo, como parâmetros de resposta. Os polinômios ortogonais foram ajustados em função das variáveis e de suas interações significantes, fixando-se o nível de significância igual ou menor de 0,05 ou 5%. Um mecanismo de oclusão do modelo experimental, para explicar a resposta mecânica do EVA, no sistema suporte + arco + placa e suporte + arco + protetor, consistiu em três eventos acoplados: 1) deformação compressiva longitudinal; 2) escorregamento entre os arcos e 3) travamento mecânico ao atingir a máxima oclusão. As variáveis, espessura da placa ou do protetor, temperatura (ambiente e bucal) e saliva (ausência ou presença), bem como algumas interações significantes entre elas, modificaram as propriedades mecânicas do EVA, no sentido de aumentar ou reduzir a resistência oferecida, por este material, ao esforço compressivo, dependendo de como os níveis das respectivas variáveis eram combinados. A resposta mecânica do EVA no sistema suporte + arco + protetor diferiu do sistema suporte + arco + placa, pois os intervalos de espessuras médias dos protetores e das placas foram significativamente diferentes. O mecanismo de oclusão do modelo experimental proposto justifica as diferenças de comportamento mecânico observadas para as duas configurações estudadas. Para placas ou protetores mais finos, da ordem de 2mm, o escorregamento acoplado ao travamento mecânico foram dois eventos determinantes. Para as placas mais espessas, da ordem de 4 mm, o comportamento mecânico pode ser explicado por três eventos acoplados: deformação compressiva longitudinal, escorregamento entre os arcos e travamento mecânico, ao atingir a máxima oclusão. / An experimental model of dental arch, moulded in epoxy, was used to study the mechanic behaviour of a copolymer of ethylene and vinyl acetate (EVA), in the form of a flat plaque or mouth protector in function of three variables: thickness, temperature and the absence or presence of artificial saliva. The evaluation of the mechanical behaviour of EVA, as a plaque or as a mouth protector, was made with the use of two factorial statistical projection, 3x2x2 and 23, respectively, in a universal test machine. The mechanic properties of EVA, at compressive effort, evaluated in two configurations (support + arch + plaque and support + arch + mouth protector) were: maximum absorbed energy (J.mm-1), maximum strain (N.mm-1), maximum displacement (mm) and maximum force (N). The effect of the variables (thickness, temperature and absence or presence of artficial saliva) were shaped, mathematically, by using the mechanical properties of EVA to compressive effort as a reply parameter. The orthogonal polynomials were adjusted in function of the variables and their significant interactions, fixing the level of significancy as 0,05 (5%) or less. A mechanism of occlusion of the experimental model, to explain the mechanic answer of EVA in the system support + arch + plaque and support + arch + protector, consisted of three connected events: 1) longitudinal compressive deformation; 2) sliding between the arches and 3) mechanic lockage on maximum occlusion. The variables, thickness of the plaque or mouth protector, temperature (local or mouth) e saliva (presence or absence), as well as some significant interactions between them, modified the mechanic properties of EVA, in the sense of increasing or reducing the resistence of this material to the compressive effort, depending on the way these variables were combined. The mechanic answer of EVA in the system support + arch + mouth protector differed from the system support + arch + plaque, as the intervals of average thickness of the mouth protectors and of the plaque were significantly distinct. The mechanism of occlusion of the experimental model proposed justifies the differences of mechanical behaviour observed in both configurations studied. In thinner plaques or mouth protectors, approximately of 2 mm, the sliding connected to the mechanic lockage were two determinant events. For thicker plaques, approximately of 4 mm, the mechanical behaviour can be explained by three linked events: longitudinal compressive deformation, sliding between the arches and mechanic locakge, on the maximum occlusion.
670

Adaptação de infraestruturas metálicas de próteses fixas sobre implantes instalados na maxila por meio da cirurgia virtual guiada / Adaptation of metal frameworks fixed prostheses on implants placement in the maxilla by guided virtual surgery

Souza, Glaís Ferrari de 20 September 2012 (has links)
Com o avanço tecnológico, a associação da tomografia computadorizada (TC) e da prototipagem rápida (PR) trouxe um recurso valioso em Implantodontia, a cirurgia virtual guiada. Dentre as vantagens dessa técnica está a possibilidade da confecção da prótese dentária previamente ao ato cirúrgico, porém, para isso, ainda há muitas falhas a serem supridas. O objetivo deste estudo foi analisar a adaptação marginal de infraestruturas metálicas de próteses fixas sobre implantes pré-confeccionadas, por meio da cirurgia virtual guiada, em modelos experimentais. Foram confeccionados dez modelos de maxila totalmente desdentada, divididos em dois grupos aleatoriamente: cinco com as guias tomográfica e cirúrgica fixadas pela técnica convencional de cirurgia virtual guiada, denominado Grupo I (GI); cinco com as guias modificadas pela sua fixação ao sistema de encaixe oring de ortoimplantes, representando o grupo II (GII). Com os dados obtidos a partir de tomografia computadorizada foi realizado um planejamento virtual de cada grupo, para a instalação de quatro implantes nas regiões dos dentes 26, 13, 16 e 23 (D, B, A, C), instalados nesta sequência. De acordo com o planejado, foi confeccionada uma guia cirúrgica prototipada e uma infraestrutura metálica de prótese fixa, para cada grupo. A adaptação das estruturas metálicas foi avaliada sob dois aspectos: a passividade (passividade A e D) e desajuste vertical (Todos), usando um microscópio óptico. O desajuste vertical foi mensurado com todos os parafusos protéticos apertados com torque de 10Ncm. Os resultados mostraram que o método de aperto Todos, no GII (A - 0,130 mm; B - 0,110 mm; C - 0,200 mm; D - 0,100 mm), foi a situação mais próxima do aceitável clinicamente, pois somente o implante C apresentou valor maior que 0,150 mm. Tanto no GI quanto no GII, a passividade D obteve melhores resultados do que em passividade A. A partir destes resultados, concluiu-se que: na condição Todos, o GII apresentou melhor adaptação marginal das infraestruturas metálicas quando comparado ao GI; o uso do ortoimplante associado ao sistema de retenção oring auxiliou na estabilidade das guias tomográfica e cirúrgica do GII; infraestruturas metálicas de próteses fixas sobre implantes pré-confeccionadas por meio da cirurgia virtual guiada não alcançaram adaptação marginal aceitável. / The combination of computed tomography (CT) and rapid prototyping (RP) has brought a valuable resource in dental implants, guided virtual surgery. Among the advantages of this technique is the possibility of manufacturing the dental prosthesis prior to surgery, but for this, there are still many failures to be addressed. The objective of this study was to analyze the marginal adaptation of prefabricated metal frameworks of fixed implant prostheses placement by virtual guided surgery in experimental models. Ten models of edentulous maxilla were randomly divided into two groups of five: GI and GII. The tomography guide and prototyping surgery in GI group were installed by conventional technique whereas in GII group they were retained by an orthodontic implants modified with o´ring system. From data obtained by CT, the virtual planning was accomplished for placement of four implants on the region of teeth 26, 13, 16, 23 (D, B, A, C) to be installed on this sequence. A prototyped surgical guide was manufactured for each group from the virtual planning and the metal framework was made using this guide. Four implants were installed in each model according to the planning by guided virtual surgery technique. The marginal adaptation of metal frameworks was evaluated from two aspects: passivity (passivity A and D) and vertical misfit (All). The level of vertical misfit frameworks was measured while all retaining screws tightened with torque 10Ncm. We used a standard method of tightening the screws, DBAC, so that the structure is fixed in the same sequence of installation of the implant. The results showed that the method of tightening of all the screws GII (A-0.130 mm, B-0.110 mm; C-0.200 mm and D-0.100 mm) was the most close to clinically acceptable, since only the implant C vertically, showed values higher than 0.150 mm. Both GI and GII, the passivity method D yielded better results than in passivity A. From the results it is concluded that, provided All the GII showed better marginal adaptation of metal framework when compared to GI, the use of the modified orthodontic implant, helped the stability of surgical guides and tomography of the GII; metal framework fixed prosthesis on implants, prefabricated through guided virtual surgery, did not reach acceptable marginal fit.

Page generated in 0.1239 seconds