Shielding study against high-energy neutrons produced in a proton therapy facility by means of Monte Carlo codes and on-site measurements / Etude de blindages pour un faisceau de protons thérapeutique: simulations par les méthodes de Monte Carlo et mesures au centre de protonthérapie d'Essen

Vanaudenhove, Thibault 12 June 2014 (has links)
Over the last few decades, radiotherapy using high-energy proton beams over the range from 50 MeV to 250 MeV has been increasingly used and developed. Indeed, it offers the possibility to focus the dose in a very narrow area around the tumor cells. The tumor control is improved compared to radiotherapy using photon beams and the healthy cells around the tumor are not irradiated since the range of charged particles is limited. However, due to nuclear reactions of the incident charged particles in the tissue, secondary high-energy radiations, essentially photons and neutrons, are produced and irradiate the treatment room.<p>As a consequence, thick concrete shielding walls are placed around the treatment room to ensure that other people and workers received a dose as small as possible. The dose measurement is performed with specific dosemeters such as the WENDI-II, which gives a conservative estimation of the ambient dose equivalent up to 5 GeV. The dose in working areas may also be estimated by means of numerical calculations by using simulation codes of particle transport such as the GEANT4, MCNPX, FLUKA and PHITS Monte Carlo codes.<p>Secondary particle yields calculated with Monte Carlo codes show discrepancies when different physical models are used but are globally in good agreement with experimental data from the literature. Neutron and photon doses decrease exponentially through concrete shielding wall but the neutron dose is definitely the main component behind a wall with sufficient thickness. Shielding parameters, e.g. attenuation coefficients, vary as functions of emission angle (regarding the incident beam direction), incident proton energy, and target material and composition.<p>The WENDI-II response functions computed by using different hadronic models show also some discrepancies. Thermal treatment of hydrogen in the polyethylene composing the detector is also of great importance to calculate the correct response function and the detector sensitivity.<p>Secondary particle sources in a proton therapy facility are essentially due to losses in cyclotron and beam interactions inside the energy selection system, with the treatment nozzle components and the target - patient or phantom. Numerical and experimental results of the dose in mazes show a good agreement for the most of detection points while they show large discrepancies in control rooms. Indeed, statistical consistency is reached with difficulty for both experimental and calculated results in control rooms since concrete walls are very thick in this case.<p>/<p>La radiothérapie utilisant des faisceaux de protons d’énergie entre 50 MeV et 250 MeV s’est largement développée ces dernières années. Elle a l’immense avantage de pouvoir concentrer la dose due au faisceau incident de manière très efficace et très précise sur la tumeur, en épargnant les éventuels organes sains et sensibles aux radiations situés aux alentours. Cependant, des rayonnements « secondaires » très énergétiques sont créés par les réactions nucléaires subies par les protons lors de leur parcours dans les tissus, et peuvent sortir du patient. Des blindages entourant la salle de traitement et suffisamment épais doivent être présents afin que la dose reçue par les personnes se trouvant aux alentours soit la plus faible possible. La mesure de la dose se fait avec des dosimètres spécifiques et sensibles aux rayonnements de haute énergie, tels que le WENDI-II pour les neutrons. L’estimation de cette dose, et donc la modélisation des blindages, se fait également avec des codes de simulation numérique de transport de particules par les méthodes de Monte Carlo, tels que GEANT4, MCNPX, FLUKA et PHITS.<p>La production de rayonnements secondaires calculée à l’aide de codes Monte Carlo montre des écarts significatifs lorsque différents modèles d’interactions physiques sont utilisés, mais est en bon accord avec des données expérimentales de référence. L’atténuation de la dose due aux neutrons et aux photons secondaires à travers un blindage composé de béton est exponentielle. De plus, la dose due aux neutrons est clairement la composante dominante au-delà d’une certaine épaisseur. Les paramètres d’atténuation, comme par exemple le coefficient d’atténuation, dépendent de l’angle d’émission (par rapport à la direction du faisceau incident), de l’énergie des protons incidents et de la nature et la composition de la cible.<p>La fonction de réponse du dosimètre WENDI-II montre également des variations lorsque différents modèles physiques sont considérés dans les codes Monte Carlo. La prise en compte d’effets fins comme les états de vibration et de rotation des atomes d’hydrogène au sein du polyéthylène composant le détecteur se révèle essentielle afin de caractériser correctement la réponse du détecteur ainsi que sa sensibilité.<p>L’émission secondaire dans un centre de protonthérapie est essentiellement due aux pertes dans le cyclotron et aux interactions du faisceau avec les systèmes de sélection de l’énergie, les composants de la tête de tir et le patient (ou le fantôme). L’évaluation numérique de la dose dans les labyrinthes des différentes salles du centre montre un bon accord avec les données expérimentales. Tandis que pour les points de mesure dans leur salle de contrôle respective, de larges différences peuvent apparaitre. Ceci est en partie dû à la difficulté d’obtenir des résultats statistiquement recevables du point de vue expérimental, mais aussi numérique, au vu de l’épaisseur des blindages entourant les salles de contrôle. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
12

Développement d'un modèle analytique dédié au calcul des doses secondaires neutroniques aux organes sains des patients en protonthérapie / Development of an analytical model to estimate stray neutron doses to healthy organs of patients undergoing proton therapy treatments

Bonfrate, Anthony 24 November 2016 (has links)
Les doses secondaires neutroniques ne sont actuellement pas estimées lors de la planification de traitement dans les centres de protonthérapie puisque les logiciels de planification de traitement (TPS) ne le proposent pas tandis que les simulations Monte Carlo (MC) et les mesures sont inadaptées pour un environnement clinique. L’objectif de la thèse est de développer un modèle analytique dédié à l’estimation des doses secondaires neutroniques aux organes sains qui reste pratique et simple d’utilisation en routine clinique. Dans un premier temps, la géométrie existante de la gantry installée au Centre de protonthérapie d’Orsay (CPO) de l’institut Curie modélisée avec le code de calcul MCNPX a été étendue à trois configurations de traitement supplémentaires (énergie en entrée de ligne de 162, 192 et 220 MeV). Une approche comparative simulation-mesure a ensuite été entreprise afin de vérifier la capacité de ces modélisations à reproduire les distributions de doses (en profondeur et latérales) des protons primaires ainsi que le champ secondaire neutronique. Des écarts inférieurs à 2 mm ont été observés pour les protons primaires. Pour les neutrons secondaires, les écarts sont plus mitigés avec des rapports simulation sur mesure de ~2 et de ~6, respectivement pour la spectrométrie et les équivalents de dose dans un fantôme physique. L’analyse des résultats a permis d’identifier l’origine de ces écarts et de mettre en perspective la nécessité de conduire de nouvelles études pour améliorer à la fois les mesures expérimentales et les simulations MC. Dans un deuxième temps, une approche purement numérique a été considérée pour calculer les doses neutroniques aux organes sains de fantômes voxélisés représentant des patients d’un an, de dix ans et adulte, traités pour un craniopharyngiome. Une variation de chaque paramètre de traitement a été réalisée afin d’étudier leur influence respective sur les doses neutroniques. Ces paramètres ont pu être ordonnés par ordre décroissant d’influence : incidence de traitement, distance organe-collimateur et organe-champ de traitement, taille/âge des patients, énergie de traitement, largeur de modulation, ouverture du collimateur, etc. Des suggestions ont également été avancées pour réduire les doses neutroniques.Dans un troisième temps, un modèle analytique a été conçu de façon à être utilisable en routine clinique, pour tous les types de tumeur et toutes les installations de protonthérapie. Son entraînement séparé pour trois incidences de traitement a montré des écarts inferieurs à ~30% et ~60 µGy Gy⁻¹ entre les données d’apprentissage (doses neutroniques calculées aux organes sains) et les valeurs prédites par le modèle analytique. La validation a consisté à comparer les doses neutroniques estimées par le modèle analytique à celles calculées avec MCNPX pour des conditions différentes des données d’apprentissage. Globalement, un accord acceptable a été observé avec des écarts moyens de ~30% et ~100 µGy Gy⁻¹. La flexibilité et la fiabilité du modèle analytique ont ainsi été mises en évidence. L’entraînement du modèle analytique à partir d’équivalents de dose neutroniques mesurés dans un fantôme solide au Centre Antoine Lacassagne a confirmé son universalité, bien qu’il requière néanmoins quelques ajustements supplémentaires pour améliorer sa précision. / Stray neutron doses are currently not evaluated during treatment planning within proton therapy centers since treatment planning systems (TPS) do not allow this feature while Monte Carlo (MC) simulations and measurements are unsuitable for routine practice. The PhD aims at developing an analytical model dedicated to the estimation of stray neutron doses to healthy organs which remains easy-to-use in clinical routine. First, the existing MCNPX model of the gantry installed at the Curie institute - proton therapy center of Orsay (CPO) was extended to three additional treatment configurations (energy at the beam line entrance of 162, 192 and 220 MeV). Then, the comparison of simulations and measurements was carried out to verify the ability of the MC model to reproduce primary proton dose distributions (in depth and lateral) as well as the stray neutron field. Errors within 2 mm were observed for primary protons. For stray neutrons, simulations overestimated measurements by up to a factor of ~2 and ~6 for spectrometry and dose equivalent in a solid phantom, respectively. The result analysis enabled to identify the source of these errors and to put into perspective new studies in order to improve both experimental measurements and MC simulations. Secondly, MC simulations were used to calculate neutron doses to healthy organs of a one-year-old, a ten-year-old and an adult voxelized phantoms, treated for a carniopharyngioma. Treatment parameters were individually varied to study their respective influence on neutron doses. Parameters in decreasing order of influence are: beam incidence, organ-to-collimator and organ-to-treatment field distances, patient’ size/age, treatment energy, modulation width, collimator aperture, etc. Based on these calculations, recommendations were given to reduce neutron doses. Thirdly, an analytical model was developed complying with a use in clinical routine, for all tumor localizations and proton therapy facilities. The model was trained to reproduce calculated neutron doses to healthy organs and showed errors within ~30% and ~60 µGy Gy⁻¹ between learning data and predicted values; this was separately done for each beam incidence. Next, the analytical model was validated against neutron dose calculations not considered during the training step. Overall, satisfactory errors were observed within ~30% and ~100 µGy Gy⁻¹. This highlighted the flexibility and reliability of the analytical model. Finally, the training of the analytical model made using neutron dose equivalent measured in a solid phantom at the center Antoine Lacassagne confirmed its universality while also indicating that additional modifications are required to enhance its accuracy.
13

Modélisation et analyse des étapes de simulation des émetteurs de positons générés lors des traitements en protonthérapie - du faisceau à la caméra TEP - pour le suivi des irradiations / Modeling and analysis of all the positron emitters simulation steps generated during the treatment phase in protontherapy - from the beam to the PET camera - for the follow-up of the irradiations

Van Ngoc Ty, Claire 19 December 2012 (has links)
La protonthérapie est une technique innovante de traitement des cancers dans les zones critiques, telles que les yeux ou la base du crâne. Même si le phénomène physique d’interactions des protons dans les tissus est bien connu et présente des avantages pour la protonthérapie, il existe des incertitudes sur le parcours des protons liées aux hétérogénéités des tissus traversés en situation clinique et liées au calcul des paramètres du faisceau dans le planning de traitement qui contrebalancent les avantages théoriques des protons pour la délivrance de la dose. Des méthodes de contrôle de qualité de l’irradiation ont donc été proposées. La plupart reposent sur l’exploitation de la cartographie des émetteurs de positons générés lors de l’irradiation. Ceux-ci peuvent être détectés et quantifiés à l’aide de la tomographie par émission de positons (TEP), une technique d’imagerie médicale utilisée principalement pour établir le bilan d’extension des cancers par imagerie. Des acquisitions TEP ont donc été proposées et validées sur des fantômes et chez des patients après protonthérapie pour le contrôle du parcours des protons. Le contrôle s’effectue en comparant la distribution radioactive mesurée en TEP et la distribution β+ simulée. La simulation de l’activité positronique générée par les protons dans le milieu traversé peut être décomposée en plusieurs étapes : une étape de simulation du faisceau de protons, une étape de modélisation des interactions des protons dans l’objet irradié et une étape d’acquisition TEP. Différentes modélisations de ces étapes sont possibles. Au cours de cette thèse, nous avons proposé plusieurs modélisations pour les 3 étapes et nous avons évalué l’apport pour la qualité du contrôle de l’irradiation. Nous avons restreint notre évaluation à la vérification du parcours des protons. Ce travail de thèse s’appuie sur des irradiations en milieu homogène et inhomogène (dans un modèle de tête) réalisé au centre de protonthérapie d’Orsay. Les objets irradiés ont été transportés dans le Service Hospitalier Frédéric Joliot pour l’acquisition TEP. Nous avons comparé l’incertitude sur le parcours des protons à partir des modélisations de la distribution β+ obtenues : 1) En modélisant l’irradiation par un faisceau de protons sous une forme simplifiée et par simulation Monte Carlo. En modélisant la production des émetteurs β+ dans les tissus par simulation Monte Carlo avec le logiciel GEANT4 en incluant les modèles de physiques des versions 9.2 et 9.4 et en utilisant des sections efficaces ; 2) En modélisant l’acquisition TEP avec une modélisation simplifiée et une modélisation Monte Carlo de l’acquisition par la caméra TEP ; 3) Les résultats montrent qu’une modélisation simplifiée du faisceau n’affecte pas l’estimation du parcours des protons. La modélisation Monte-Carlo de la caméra permet de mieux modéliser le bruit présent dans le signal TEP mesuré en milieu homogène. Des résultats préliminaires de la modélisation de la caméra TEP sont présentés dans un modèle de tête (inhomogène). En conclusion, une modélisation simplifiée de la caméra TEP permet d’évaluer le parcours des protons en milieu homogène à 1 mm près, qui est équivalent à la reproductibilité de la mesure TEP post-irradiation telle qu’elle est mesurée par Knopf et al. (2008). / The protontherapy is an innovative technique for cancer treatment in critical areas, such as the eye or the head. Even though the interaction of protons with human tissues is a well-known physical phenomenon which gives rise to the protontherapy, there are uncertainties on the proton trajectory due to heterogeneities in the irradiated tissue, the calculation of the beam parameters in the planning treatment affects the theoretical benefits of the protons and the chosen dose delivery process. Thus, methods for irradiation quality control have been suggested. Most of them rely on utilizing the mapping of the positron emitters generated during the irradiation. They are detectable and quantifiable thanks to the use of the PET (positron emitter tomography), a medical imaging technique mainly used for the cancer expansion assessment. PET acquisitions were proposed and then realized on phantoms and patients after protontherapy. The quality control relies on comparing the measured radioactive distribution to the simulated β+ distribution. The modeling of the positronic activity generated by protons in the irradiated area can be divided into three steps: the simulation of the proton beam, the modeling of the proton interactions in the irradiated object and the modeling of the PET acquisition. Different ways of simulating these steps are possible. This PhD work suggests different ways of modeling the three steps and evaluates theirs benefits for the irradiation quality control. We have restrained our evaluation to the verification of the proton range and to the uncertainties related to the proton range. This research work utilizes on irradiations in homogenous and inhomogeneous areas in a head model. We have compared the uncertainties on the proton range measured thanks to the following β+ distributions: 1) A β+ distribution obtained by modeling the irradiation with a proton beam simulated analytically and simulated using the complete Monte Carlo method; 2) A Monte Carlo modeling of the proton range using the GEANT4 software (versions 9.2 and 9.4) relying and using cross-sections; 3) A simulation of the PET acquisition using a simplified modeling and a Monte Carlo modeling. Our results show that a simplified modeling of the beam does not affect the estimation of the proton range. Besides, the Monte Carlo modeling of the PET camera enables modeling the noise present in the PET signal measured in a homogeneous area. Preliminary results of the PET camera modeling are presented in a head model (inhomogeneous). Finally, a simplified modeling of the PET camera enables evaluate the proton range in a homogeneous area with a 1mm-precision, which is equivalent to the reproducibility of the PET offline measure as described in (Knopf et al., 2008).
14

Les accélérateurs à champ fixe et gradient alterné FFAG et leur application médicale en protonthérapie.

Fourrier, Joris 17 October 2008 (has links) (PDF)
La radiothérapie utilise des faisceaux de particules dans le but d'irradier et d'éliminer les tumeurs cancéreuses tout en épargnant au maximum les tissus sains. La perte d'énergie en forme de pic de Bragg des protons dans la matière permet une amélioration balistique du dépôt de la dose par rapport aux rayons X. Le volume irradié peut ainsi être précisément ajusté au volume tumoral. Cette thèse, dans le cadre du projet RACCAM, vise à étudier et à mettre au point le design d'une installation de protonthérapie basée sur un accélérateur de particules à champ fixe et à gradient alterné FFAG dans le but de construire un aimant FFAG à secteur spiral pour validation. Nous présentons tout d'abord la protonthérapie pour définir un cahier des charges médicales définissant les critères techniques d'une installation de protonthérapie. Puis nous introduisons les accélérateurs FFAG par une présentation des projets passés et en cours dans le monde avant de développer la théorie de la dynamique faisceau dans le cas de l'optique à focalisation invariante. Nous décrivons ensuite les outils de modélisation et simulation mis au point pour étudier cette dynamique faisceau dans une optique FFAG à focalisation invariante et à secteur spiral. Nous expliquons par la suite la recherche des paramètres de l'optique ayant abouti à la construction d'un aimant prototype. Enfin, nous décrivons l'installation de protonthérapie du projet RACCAM depuis le cyclotron injecteur jusqu'au système d'extraction.
15

Monte Carlo simulation of active scanning proton therapy system with Gate/Geant4 : Towards a better patient dose quality assurance / Simulation Monte Carlo d’un système de protonthérapie à balayage actif avec Gate/Geant4 : Vers une meilleure assurance qualité de la dose délivrée au patient

Grevillot, Loïc 14 October 2011 (has links)
L’hadronthérapie est une technique avancée de traitement du cancer par radiothérapie. Elle offre une ballistique d’irradiation bien supérieure à la radiothérapie conventionnelle, mais nécessite également un contrôle qualité plus poussé. Dans ce travail, nous avons implémenté de nouveaux outils dans la plateforme Monte Carlo GATE, afin de pouvoir recalculer des plans de traitements issus d’un Système de Plannification de Traitement (TPS). Tout d’abord, nous avons défini un environnement de simulation permettant de réaliser des calculs précis et éfficaces. Les simulations ont été validées avec des mesures et d’autres codes Monte Carlo, pour des profils de dose en profondeur et transverses. Un bon accord a été obtenu pour les profils de dose en profondeur, mais des écarts plus marqués ont été observés pour les profils transverses. Ensuite, une méthode de modélisation pour des systèmes de traitement à balayage actif de faisceau étroit (PBS) a été proposée. Elle a été appliquée à un système de protonthérapie IBA et validée par comparaison à des mesures pour des champs complexes. Une interface permettant de faire le lien entre GATE et des fichiers DICOM RT ION PLAN et DICOM RT DOSE a également été réalisée. Enfin, nous avons comparé des distributions de dose TPS et Monte Carlo en milieux homogènes et hétérogènes. Les modèles de faisceau implémentés dans ces deux outils dosimétriques ont montré un accord satisfaisant en milieu homogène, mais les limites du TPS ont été mises en évidence dans des milieux hétérogènes. Un plan de prostate composé de deux champs latéraux opposés a été simulé et comparé avec le TPS, démontrant les nouvelles capacités de la plateforme. Dans cette thèse de doctorat, nous avons montré que la plateforme Monte Carlo GATE est un bon candidat pour la simulation de plans de traitements PBS et peut permettre l’évaluation des algorithmes de calcul de dose implémentés dans les TPSs. Cette plateforme supporte également des applications d’imagerie, telles que l’imagerie PET ou gamma-prompt et ouvre la porte à des recherches multidisciplinaires innovantes. / Hadron Therapy is an advanced radiotherapy technique for cancer treatment. It offers a better irradiation ballistic than conventional techniques and therefore requires appropriate quality assurance procedures. In this work, we upgraded the GEANT4-based GATE Monte Carlo platform in order to recalculate the TPS dose distributions in view of further benchmarking. In a first step, we selected an appropriate simulation environment (physics models and parameters) in order to produce accurate and efficient simulations. GATE simulations were validated using measurements and other Monte Carlo codes for depth-dose and transverse profiles. While a good agreement was found for depth-dose profiles, larger discrepancies were pointed out for transverse profiles. In a second step, we developed a modeling method to simulate active scanning beam delivery systems, which does not require to simulate the components of the treatment nozzle. The method has been successfully applied to an IBA proton therapy system and validated against measurements for complex treatment plans. Interfaces have also been developed in order to link DICOM RT ION PLAN and DICOM RT DOSE with GATE. Finally, we compared in a third step the TPS and Monte Carlo dose distributions in homogeneous and heterogeneous configurations. The beam models of both dose engines were in satisfactory agreement, allowing further evaluation of clinical treatment plans. A two-field prostate plan has been evaluated, showing a satisfactory agreement between the TPS and Monte Carlo, and demonstrating the novel capabilities of the platform for the evaluation of the TPS. To summarize, we selected an appropriate simulation environment for proton therapy, proposed a modeling method for active scanning systems and presented a method to compare the TPS and Monte Carlo dose distributions. All tools developed in GATE were or will be publicly released. A detailed validation stage of the system including absolute dosimetry is still necessary, in order to quantitatively evaluate its accuracy in various homogeneous and heterogeneous configurations. In this thesis, we have demonstrated that the GATE Monte Carlo platform is a good candidate for the simulation of active scanning delivery systems, allowing further TPS benchmarking. Moreover, the GATE platform also handles imaging applications, such as PET or prompt-gamma imaging towards online treatment monitoring and paves the way of interdisciplinary research advances.
16

Étude des performances d'un système d'imageur proton dans le cadre de l'approche faisceau à faisceau / Performance study of a spot beam approach to proton imaging

Karakaya, Yusuf 11 July 2018 (has links)
L'étalonnage de l’image tomodensitométrique X en pouvoirs d’arrêt relatif est source d'incertitudes pour la planification du traitement en protontherapie. L’imagerie proton permettrait d’obtenir directement les pouvoirs d’arrêt ou les épaisseurs équivalent-eau tout en maîtrisant les incertitudes sur la planification du traitement. Ce travail vise à caractériser et optimiser les performances du système de tomographie proton proposé dans le cadre d’une nouvelle approche faisceau à faisceau, composé d’un trajectographe et d’un range meter. La position et la largeur du faisceau obtenues avec le trajectographe ainsi que la modélisation matricielle de la réponse du range meter par simulation Monte Carlo combinée à la déconvolution de la courbe de Bragg résiduelle ont permis de reconstruire l’épaisseur équivalent-eau traversée pour chaque faisceau. L’évaluation de la qualité des images a permis de montrer que la méthode de déconvolution permettait d’obtenir des images dépourvues d’artefacts et d’estimer le parcours du proton avec une précision de l’ordre de 0,7%. Le travail présenté dans cette thèse démontre la faisabilité d’un tel système d’imagerie. / Calibration of computed tomography image in relative stopping power is a source of uncertainties for the proton therapy treatment planning. Proton imaging could directly obtain stopping powers or equivalent water thicknesses and control uncertainties in the treatment planning. In the context of a new pencil beam approach, this work aims to characterize and optimize the performances of a proton tomography system consisting of a tracker and a range meter. Beam position and width obtained with the tracker and the range meter response matrix modelling by Monte Carlo simulation combined with the unfolding method of the residual Bragg curve enable to reconstruct the water equivalent thickness for each beam. The evaluation of the reconstructed images quality shows that images are artefact free and the proton range is estimated with 0.7% of accurancy by using the unfolding method. This thesis demonstrates the feasibility of such an imaging system.
17

Characterization of the GATE Monte Carlo platform for non-isocentric treatments and patient specific treatment plan verification at MedAustron - Vienna - Austria / Caractérisation de la plate-forme GATE Monte Carlo pour les traitements non isocentriques et vérification du plan de traitement spécifique au patient chez MedAustron - Vienna - Austria

Elia, Alessio 08 January 2019 (has links)
L'objectif de cette thèse est de développer et de valider une méthode de calcul de dose indépendante afin de soutenir le travail de mise en service intense d'une installation de traitement par faisceaux d'ions légers (LIBT) et de valider le calcul de dose du système de planification de traitement (SP). Le travail porte sur les traitements de protonthérapie et est organisé en collaboration entre le laboratoire CREATIS (Lyon, France) et le centre de thérapie ionique MedAustron - Vienna - Austria (Wiener Neustadt, Autriche). Chez MedAustron - Vienna - Austria, afin d’exploiter une pénombre latérale aiguë du faisceau de protons et d’améliorer la précision des algorithmes de calcul de la dose TPS, l’intervalle entre la fenêtre de la tête de traitement et le patient est réduit en déplaçant le patient vers la tête de traitement. Par conséquent, les traitements non isocentriques doivent être pris en compte avec précision lors de la modélisation ainsi que lors de la phase de validation, car l'éloignement de la cible de l'isocentre de la pièce peut réduire la précision du traitement. Dans cette étude, la paramétrisation du faisceau de crayons à protons suit les recommandations de Grevillot et al. (2011), mais comprenant une description complète de la buse. Un soin particulier est apporté à la modélisation des propriétés du faisceau de crayon dans des conditions non isocentriques, y compris l'utilisation d'un Range Shifter (RaShi). La caractérisation du faisceau de crayon est basée uniquement sur les profils de fluence mesurés dans le profil de dose d’air et de profondeur acquis dans l’eau. De plus, le modèle présenté est calibré en dose absolue sur la base d'un nouveau formalisme produit-zone-dose présenté dans Palmans et Vatnitsky (2016). Finalement, une validation détaillée est effectuée dans l'eau, pour les distributions de doses tridimensionnelles de forme régulière. Plusieurs paramètres couramment exploités en dosimétrie des protons, tels que la distance parcourue, la pénombre distale, la modulation, la taille des champs et la pénombre latérale pour la dosimétrie protonique sont évalués à des fins de validation. Le modèle optique à faisceau de crayon a atteint une précision de l'exigence clinique de 1 mm / 10% et il n'est pas affecté par la complexité des traitements non isocentriques ni par l'utilisation d'un RaShi. Les plages sont reproduites entre 0,2 et 0,35 mm (déviation maximale) sans et avec le décaleur de plage, respectivement. La différence de dose dans les conditions de référence est de 0,5%. La validation de l'administration de la dose en 3D dans l'eau était à 1,2% maximum. La concordance des paramètres distaux et longitudinaux est généralement meilleure que 1 mm. Les résultats obtenus serviront de référence pour la future mise en œuvre clinique du système de calcul de dose indépendant MedAustron - Vienna - Austria. / The goal of this PhD is to develop and validate an independent dose calculation method in order to support the intense commissioning work of a Light Ion Beam Therapy (LIBT) facility, and to validate the Treatment Planning System (TPS) dose calculation. The work focuses on proton therapy treatments and is held as a collaboration between the CREATIS laboratory (Lyon, France) and the MedAustron - Vienna - Austria Ion Therapy Center (Wiener Neustadt, Austria). At MedAustron - Vienna - Austria, in order to exploit a sharp lateral penumbra for the proton beam as well as to improve the accuracy of the TPS dose calculation algorithms, the air gap between the treatment head window and the patient is reduced by moving the patient towards the treatment head. Therefore, non-isocentric treatments have to be accurately taken into consideration during modeling as well as validation phase as moving the target away from the room isocenter may lead to reduced treatment accuracy. In this study, the parametrization of the proton pencil beam follows the recommendations provided in Grevillot et al. (2011), but including a full nozzle description. Special care is taken to model the pencil beam properties in non-isocentric conditions, including the use of a Range Shifter (RaShi). The characterization of the pencil beam is based solely on fluence profiles measured in air and depth dose profile acquired in water. In addition, the presented model is calibrated in absolute dose based on a newly formalism in dose-area-product presented in Palmans and Vatnitsky (2016). Eventually, a detailed validation is performed in water, for three-dimensional regular-shaped dose distributions. Several parameters commonly exploited in proton dosimetry such as range, distal penumbra, modulation, field sizes and lateral penumbra for proton dosimetry are evaluated for validation purposes. The pencil beam optics model reached an accuracy within the clinical requirement of 1mm/10% and it is not affected by the complexity of non-isocentric treatments and the use of a RaShi. Ranges are reproduced within 0.2 and 0.35 mm (max deviation) without and with range shifter, respectively. The dose difference in reference conditions is within 0.5%. The 3D dose delivery validation in water was within 1.2% at maximum. The agreement of distal and longitudinal parameters is mostly better than 1 mm. The obtained results will be used as a reference for the future clinical implementation of the MedAustron - Vienna - Austria independent dose calculation system. As an example of the potential clinical outcome of the presented work, the patient specific quality assurance measurements performed in water have been successfully reproduced within the clinical requirement of 5% accuracy for a few patients.
18

Design and implementation of a prompt-gamma camera for real-time monitoring of ion beam therapy / Conception et mise en oeuvre d'une caméra Prompt-Gamma pour la surveillance en temps réel de thérapie par faisceau d'ions

Roellinghoff, Frauke 19 March 2014 (has links)
La protonthérapie est une technique prometteuse pour le traitement du cancer, qui se répend de plus en plus. Le pic prononcé de son profil de dose ainsi que la longueur finie du parcours des particules rendent possible un traitement plus ciblé et permettent de mieux éviter d’endommager des tissus sains. Cependant, la précision de l’irradiation s’avère également être le risque principal lors de l’utilisation de cette technique. En effet, une erreur dans la profondeur de pénétration des particules pourrait engendrer des dégâts considérables. A l’heure actuelle, aucune méthode de contrôle n’est systématiquement utilisée pour s’assurer de la qualité du traitement. Dans ce manuscrit, une méthode indirecte de mesure de la distribution de dose, basé sur la détection de gammas prompts émis le long du parcours du faisceau, est étudiée. Deux concepts de caméra collimatée uni-dimensionnelle sont comparés à l’aune de leur utilisation potentielle : une caméra à fentes parallèles et une caméra “knife-edge”. Les deux systèmes sont optimisés par simulations de Monte Carlo et des mesures sont présentés pour valider ces simulations. La comparaison se base sur la précision avec laquelle un décalage dans la chute du profil prompt gamma peut être détecté, la résolution spatiale, le coût et la taille du système. Des recommandations sont émises pour le choix de la meilleure configuration, selon différentes exigeances. Des résultats similaires sont obtenus pour les deux concepts, atteignant une précision de environ 2 mm pour un seul point de “pencil beam” correspondant à 5e7 protons. L’étude se conclue par un tour d’horizon des pistes de recherche futures qui permettraient d’utiliser un système de détection de gammas prompts dans un contexte clinique futur. / Protontherapy is a promising technique for tumor treatment that is becoming more and more widespread. The sharply peaked profile of the dose and the finite particle range allow for very conformal treatment and better sparing of healthy tissue beyond the tumor, but he precise delivery also proves to be the biggest challenge of the technique. Errors in range are a considerable risk in proton therapy and no range monitoring method is currently systematically used for quality control. In this manuscript, an indirect method of measuring the dose distribution, via the detection of secondary prompt gamma radiation emitted along the beam path, is explored. Two different one-dimensional collimated camera concepts, a multi-parallel-slit camera and a knife-edge slit camera are compared with regards to their potential use. Both systems are optimized via Monte Carlo simulation and measurements are presented for validation. The comparison is made on the basis of the precision with which a shift in the prompt gamma profile falloff edge can be retrieved by comparison with a reference profile as well as the spatial resolution, the cost, weight and bulkiness of the system and guidelines are given for choosing the best configuration for different requirements. Similar values can be obtained for both concepts, reaching a precision for the retrieval of the falloff edge of around 2 mm for a single pencil beam spot of 5×107 protons. This study concludes with an outlook on future developments and areas of investigation with the goal of reaching clinical applicability of a prompt gamma detection system.
19

Dual-energy cone-beam CT for proton therapy / Tomodensitométrie conique bi-énergie pour la proton thérapie

Vilches Freixas, Gloria 27 October 2017 (has links)
La proton thérapie est une modalité de traitement du cancer qu’utilise des faisceaux de protons. Les systèmes de planification de traitement actuels se basent sur une image de l’anatomie du patient acquise par tomodensitométrie. Le pouvoir d’arrêt des protons relatif à l’eau (Stopping Power Ratio en Anglais, SPR) est déterminé à partir des unités Hounsfield (Hounsfield Units en Anglais, HU) pour calculer la dose absorbée au patient. Les protons sont plus vulnérables que les photons aux modifications du SPR du tissu dans la direction du faisceau dues au mouvement, désalignement ou changements anatomiques. De plus, les inexactitudes survenues de la CT de planification et intrinsèques à la conversion HU-SPR contribuent énormément à l’incertitude de la portée des protons. Dans la pratique clinique, au volume de traitement s’ajoutent des marges de sécurité pour tenir en compte ces incertitudes en détriment de perdre la capacité d’épargner les tissus autour de la tumeur. L’usage de l’imagerie bi-énergie en proton thérapie a été proposé pour la première fois en 2009 pour mieux estimer le SPR du patient par rapport à l’imagerie mono-énergie. Le but de cette thèse est d’étudier la potentielle amélioration de l’estimation du SPR des protons en utilisant l’imagerie bi-énergie, pour ainsi réduire l’incertitude dans la prédiction de la portée des protons dans le patient. Cette thèse est appliquée à un nouveau système d’imagerie, l’Imaging Ring (IR), un scanner de tomodensitométrie conique (Cone-Beam CT en Anglais, CBCT) développé pour la radiothérapie guidée par l’image. L’IR est équipé d’une source de rayons X avec un système d’alternance rapide du voltage, synchronisé avec une roue contenant des filtres de différents matériaux que permet des acquisitions CBCT multi-énergie. La première contribution est une méthode pour calibrer les modèles de source et la réponse du détecteur pour être utilisés en simulations d’imagerie X. Deuxièmement, les recherches ont évalué les facteurs que peuvent avoir un impact sur les résultats du procès de décomposition bi-énergie, dès paramètres d’acquisition au post-traitement. Les deux domaines, image et basée en la projection, ont été minutieusement étudiés, avec un spéciale accent aux approches basés en la projection. Deux nouvelles bases de décomposition ont été proposées pour estimer le SPR, sans avoir besoin d’une variable intermédiaire comme le nombre atomique effectif. La dernière partie propose une estimation du SPR des fantômes de caractérisation tissulaire et d’un fantôme anthropomorphique à partir d’acquisitions avec l’IR. Il a été implémentée une correction du diffusé, et il a été proposée une routine pour interpoler linéairement les sinogrammes de basse et haute énergie des acquisitions bi-énergie pour pouvoir réaliser des décompositions en matériaux avec données réelles. Les valeurs réconstruits du SPR ont été comparées aux valeurs du SPR expérimentales déterminés avec un faisceau d’ions de carbone. / Proton therapy is a promising radiation treatment modality that uses proton beams to treat cancer. Current treatment planning systems rely on an X-ray computed tomography (CT) image of the patient's anatomy to design the treatment plan. The proton stopping-power ratio relative to water (SPR) is derived from CT numbers (HU) to compute the absorbed dose in the patient. Protons are more vulnerable than photons to changes in tissue SPR in the beam direction caused by movement, misalignment or anatomical changes. In addition, inaccuracies arising from the planning CT and intrinsic to the HU-SPR conversion greatly contribute to the proton range uncertainty. In clinical practice, safety margins are added to the treatment volume to account for these uncertainties at the expense of losing organ-sparing capabilities. The use of dual-energy (DE) in proton therapy was first suggested in 2009 to better estimate the SPR with respect to single-energy X-ray imaging. The aim of this thesis work is to investigate the potential improvement in determining proton SPR using DE to reduce the uncertainty in predicting the proton range in the patient. This PhD work is applied to a new imaging device, the Imaging Ring (IR), which is a cone-beam CT (CBCT) scanner developed for image-guided radiotherapy (IGRT). The IR is equipped with a fast kV switching X-ray source, synchronized with a filter wheel, allowing for multi-energy CBCT imaging. The first contribution of this thesis is a method to calibrate a model for the X-ray source and the detector response to be used in X-ray image simulations. It has been validated experimentally on three CBCT scanners. Secondly, the investigations have evaluated the factors that have an impact on the outcome of the DE decomposition process, from the acquisition parameters to the post-processing. Both image- and projection-based decomposition domains have been thoroughly investigated, with special emphasis on projection-based approaches. Two novel DE decomposition bases have been proposed to estimate proton SPRs, without the need for an intermediate variable such as the effective atomic number. The last part of the thesis proposes an estimation of proton SPR maps of tissue characterization and anthropomorphic phantoms through DE-CBCT acquisitions with the IR. A correction for X-ray scattering has been implemented off-line, and a routine to linearly interpolate low-energy and high-energy sinograms from sequential and fast-switching DE acquisitions has been proposed to perform DE material decomposition in the projection domain with real data. DECT-derived SPR values have been compared with experimentally-determined SPR values in a carbon-ion beam.
20

Simulation et reconstruction 3D à partir de caméra Compton pour l’hadronthérapie : Influence des paramètres d’acquisition / Simulation and reconstruction from Compton caméra for hadrontherapy : Influence of the acquisition parameters

Hilaire, Estelle 18 November 2015 (has links)
L'hadronthérapie est une méthode de traitement du cancer qui emploie des ions (carbone ou proton) au lieu des rayons X. Les interactions entre le faisceau et le patient produisent des radiations secondaires. Il existe une corrélation entre la position d'émission de certaines de ces particules et la position du pic de Bragg. Parmi ces particules, des gamma-prompt sont produits par les fragments nucléaires excités et des travaux actuels ont pour but de concevoir des systèmes de tomographie par émission mono-photonique capable d'imager la position d'émission ces radiations en temps réel, avec une précision millimétrique, malgré le faible nombre de données acquises. Bien que ce ne soit pas actuellement possible, le but in fine est de surveiller le dépôt de dose. La caméra Compton est un des système TEMP qui a été proposé pour imager ce type de particules, car elle offre une meilleure résolution énergétique et la possibilité d'avoir une image 3D. Cependant, en pratique l'acquisition est affectée par le bruit provenant d'autres particules secondaires, et les algorithmes de reconstruction des images Compton sont plus compliqués et encore peu aboutis, mais sur une bonne voie de développement. Dans le cadre de cette thèse, nous avons développé une chaîne complète allant de la simulation de l'irradiation d'un fantôme par un faisceau de protons allant jusqu'à la reconstruction tomographique des images obtenues à partir de données acquises par la caméra Compton. Nous avons étudié différentes méthodes de reconstruction analytiques et itératives, et nous avons développé une méthode de reconstruction itérative capable de prendre en compte les incertitudes de mesure sur l'énergie. Enfin nous avons développé des méthodes pour la détection de la fin du parcours des distributions gamma-prompt reconstruites. / Hadrontherapy is a cancer treatment method which uses ions (proton or carbon) instead of X-rays. Interactions between the beam and the patient produce secondary radiation. It has been shown that there is a correlation between the emission position of some of these particles and the Bragg peak position. Among these particles, prompt-gamma are produced by excited nuclear fragments and current work aims to design SPECT systems able to image the emission position the radiation in real time, with a millimetric precision, despite the low data statistic. Although it is not currently possible, the goal is to monitor the deposited dose. The Compton camera is a SPECT system that proposed for imaging such particles, because it offers a good energy resolution and the possibility of a 3D imaging. However, in practice the acquisition is affected by noise from other secondary particles and the reconstruction algorithms are more complex and not totally completed, but the developments are well advanced. In this thesis, we developed a complete process from the simulation of irradiation of a phantom by a proton beam up to the tomographic reconstruction of images obtained from data acquired by the Compton camera. We studied different reconstruction methods (analytical and iterative), and we have developed an iterative method able to consider the measurement uncertainties on energy. Finally we developed methods to detect the end-of-range of the reconstructed prompt-gamma distributions.