• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 230
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 238
  • 132
  • 52
  • 38
  • 34
  • 27
  • 27
  • 24
  • 24
  • 24
  • 23
  • 22
  • 20
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Análise de cádmio e chumbo em bijuterias por espectrometria de absorção atômica por chama (F AAS) e voltametria de pulso diferencial (VPD)

Ferreira, Taimara Polidoro 25 February 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-06-14T11:29:23Z No. of bitstreams: 1 taimarapolidoroferreira.pdf: 1182886 bytes, checksum: a5d4b3b0f39cb3072c8ac7463931f8e7 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T14:03:33Z (GMT) No. of bitstreams: 1 taimarapolidoroferreira.pdf: 1182886 bytes, checksum: a5d4b3b0f39cb3072c8ac7463931f8e7 (MD5) / Made available in DSpace on 2016-07-13T14:03:33Z (GMT). No. of bitstreams: 1 taimarapolidoroferreira.pdf: 1182886 bytes, checksum: a5d4b3b0f39cb3072c8ac7463931f8e7 (MD5) Previous issue date: 2016-02-25 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A análise de metais em diversos tipos de amostras, já é algo bem descrito na literatura utilizando a espectrometria de absorção atômica, que é a técnica mais popular para este tipo de análise, entretanto o desenvolvimento de técnicas eletroanalíticas para a análise de metais é algo que vem crescendo nos últimos anos. As técnicas eletroanalíticas apresentam as vantagens de conseguirem determinar baixas concentrações de metais, permitirem a determinação simultânea destes e ainda possuírem um baixo custo se comparada à técnicas espectrométricas. Devido ao aumento da preocupação da qualidade dos metais para a confecção de bijuterias, a análise de metais se torna extremamente importante uma vez que altas concentrações desses metais no organismo, em especial metais tóxicos como cádmio e chumbo, podem trazer malefícios irreversíveis para a saúde. Neste contexto, o objetivo do trabalho foi analisar cádmio e chumbo em amostras de bijuterias por voltametria de pulso diferencial (VPD) com etapa de pré-concentração e comparar com as análises por espectrometria de absorção atômica com chama (F AAS). Os parâmetros utilizados para a análise por voltametria de pulso diferencial foram: o potencial de deposição de -0,9 V com duração de 120 s e a faixa de potencial de -0,9 a 0,1 V. Dois tipos de digestão para as amostras foram testadas, em chapa de aquecimento e em um equipamento de micro-ondas, e após as digestões, as amostras foram analisadas pelas duas técnicas. A digestão por micro-ondas se mostrou mais adequada, assim como as análises por voltametria que apresentaram boa exatidão, que foi avaliada através de estudos de adição e recuperação, com resultados entre 99 a 110% para o cádmio e 99 a 105% para o chumbo. As amostras de bijuterias analisadas pela VPD e digeridas por micro-ondas continham de < LD a 4,05 % m/m de cádmio e de 0,004 a 7,55 % m/m de chumbo. Os limites de detecção foram de 0,75 mg L-1 para o cádmio e de 0,07 mg L-1 para o chumbo para a técnica de absorção atômica e os limites de detecção para a voltametria foram de 0,02 mg L-1 para o cádmio, e de 2,26.10-3 mg L-1 para o chumbo. / The metal analysis of various types of samples, using atomic absorption spectrometry, is well described in the literature. It is the most popular technique for this type of analysis; however the development of electroanalytical techniques for the analysis of metals has been growing in recent years. The electroanalytical techniques have the advantages of be able to determine low concentrations of metals, allow the simultaneous determination of these and have low cost compared to spectrometric techniques. Due to the increased concern for quality of metals for the manufacture of jewelry, the metal analysis is extremely important since high concentrations of these metals in the body, in particular toxic metals such as cadmium and lead can bring irreversible harm to health. In this context, the aim of this study was to analyse cadmium and lead in jewelry samples by differential pulse voltammetry (DPV) with pre-concentration step and compare the results with atomic absorption spectrometry with flame (F AAS). The parameters used for the analysis by differential pulse voltammetry were: deposition potential = -0.9 V, deposition time = 120 s and the potential range from -0.9 to 0.1 V. Two types of samples digestion were tested: hot plate and microwave equipment. After digestions, the samples were analyzed by both techniques (DPV and F AAS). Digestion by microwave proved most suitable, as well as voltammetry results that showed good accuracy, which was evaluated by adding and recovery studies with results from 99 to 110% for cadmium and 99 to 105% for lead. Samples of jewelry and analysed by the DPV digested microwave contained the <LOD to 4.05 % w / w cadmium and 0.004 to 7.55 % w / w of lead. The limits of detection were 0.75 mg L-1 for cadmium and 0.07 mg L-1 for lead for atomic absorption technique and limits of detection for voltammetry was 0.02 mg L-1 for cadmium, and 2.26.10-3 mg L-1 for lead.
102

Ritmo não-pulsante: ausência de sensação de pulsação no repertório do século XX

Ribeiro, Nariá Assis 14 July 2014 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-08-02T11:47:49Z No. of bitstreams: 1 nariaassisribeiro.pdf: 10094285 bytes, checksum: 0aa36747f2e32a0358afd66ce9582bd2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-08-02T12:01:23Z (GMT) No. of bitstreams: 1 nariaassisribeiro.pdf: 10094285 bytes, checksum: 0aa36747f2e32a0358afd66ce9582bd2 (MD5) / Made available in DSpace on 2018-08-02T12:01:23Z (GMT). No. of bitstreams: 1 nariaassisribeiro.pdf: 10094285 bytes, checksum: 0aa36747f2e32a0358afd66ce9582bd2 (MD5) Previous issue date: 2014-07-14 / PROQUALI (UFJF) / Os conceitos de métrica incomum com pulso obscuro de Allen Winold e o ritmo não-métrico com acentuações livres e ausência de beat perceptível de Howard Smither são tentativas de caracterizar e refletir sobre as novas formas de estruturar as durações, que surgem com a intensa experimentação musical no século XX. Esta pesquisa visa a aprofundar o conhecimento sobre a ausência de sensação de pulsação em música, ou o ritmo não-pulsante; a explorar quais decisões na interpretação de uma obra musical evidenciam ou não a sensação de pulsação para o ouvinte; e a identificar se a tentativa de construir o ritmo não-pulsante em algumas obras do século XX está ligada a algum movimento estético específico. A primeira etapa da pesquisa consistiu em revisar as definições de termos fundamentais para abordar a pulsação: pulso, beat, acento, métrica e ritmo; utilizando como base teórica os trabalhos de Cooper e Meyer, Simha Arom, Joel Lester, Lerdahl e Jackendoff. Na segunda etapa buscou-se ampliar a discussão que Winold e Smither fizeram sobre o ritmo não-pulsante, selecionando pesquisadores da teoria da música, como Bryan Simms e Leon Dallin; e compositores que pensaram em novas concepções de ritmo e sentido métrico na música do século XX, como John Cage e Pierre Boulez. Na terceira etapa foram realizadas duas análises musicais com foco na interação entre o conceito de ritmo não-pulsante, a escuta e a interpretação a partir da notação musical. / Allen Winold's and Howard Smither’s concepts of unusual metric structure with obscured pulse and nonmetrical rhythm with free accentuation and absence of perceptible beat are attempts to characterize and reflect on new methods of structuring durations that emerge from intense musical experimentation in the twentieth-century. This research aims to improve knowledge of the absence of pulse sensation in music, or nonpulsed rhythm; as well as to explore which performers’ decisions enunciate or not pulse sensation for the listener; and finally to identify whether the attempt to build the nonpulsed rhythm in some twentiethcentury works is linked to a specific aesthetic movement. The first stage of the research consisted of revising the definitions of fundamental terms to approach pulse: pulse, beat, accent, metric and rhythm; using as theoretical basis the theories of Cooper and Meyer, Simha Arom, Joel Lester, Lerdahl and Jackendoff. In the second stage we tried to expand the discussion that Winold and Smither did about nonpulsed rhythm, selecting music theory researchers such as Bryan Simms and Leon Dallin; and composers who thought of new conceptions of rhythm and metric structure in twentieth-century music, such as John Cage and Pierre Boulez. In the third stage, two musical analysis were performed focusing on the interaction between the concept of nonpulsed rhythm, musical listening and performance of notated music.
103

Avaliação da responsividade cardiovascular por meio da variação de pulso com diferentes fluídos em modelo experimental de hemodiluição normovolêmica aguda / Assessment of cardiovascular responsiveness through variation in pulse with different fluids in an experimental model of acute normovolemic hemodilution

Sant\'Ana, Alex Jader 30 June 2009 (has links)
Introdução: A variação da pressão de pulso (PP) tem se mostrado ser uma ferramenta indicadora da responsividade à terapia de fluídos em estudos clínicos e experimentais. Entretanto, esses parâmetros ainda não foram adequadamente estudados em situações de variação aguda da viscosidade sanguínea, como ocorre durante hemodiluição normovolêmica aguda (HNA). O propósito desse estudo é comparar o comportamento do PP em modelo experimental de HNA em suínos com reposição volêmica com solução salina ou colóide. Métodos: Vinte e um suínos de peso médio de 32kg foram anestesiados e randomizados em três grupos de estudo: HES, o sangue removido foi reposto com solução de amido hidroxietílico 6%; SS, solução salina a 0,9% utilizada na reposição volêmica, e grupo controle, no qual os animais foram somente anestesiados. Parâmetros hemodinâmicos foram mensurados no início do procedimento (basal) (T0), metade processo de HNA (T2), 1 hora e 2 horas depois da HNA (T3 e T4 respectivamente), e imediatamente e 1 hora depois da retransfusão sanguínea (T5, T6). Os dados foram submetidos à análise de variância para medidas repetidas, seguida de teste de Tukey. As distribuições das variáveis mensuradas em mais de uma condição de avaliação, sem distribuição normal, foram comparadas com o teste Friedman e os grupos foram comparados com o teste de Mann-Whitney. Os valores de p<0,05 foram considerados estatisticamente significantes. Resultados: Depois da HNA, os parâmetros dinâmicos de responsividade a reposição volêmica, representados pelo PP, foram diferentes quando os animais foram tratados com solução colóide ou cristalóide (6,1 ± 2,5 e 14,1 ± 3,4 respectivamente). Os parâmetros estáticos tais como pressão de oclusão de artéria pulmonar (HES 11 ± 3; SS 8 ± 3) e pressão venosa central (HES 8 ± 2; SS 7 ± 4) são contraditórios quando comparados com PP. Conclusão: Durante o processo de HNA a solução colóide mantém os valores de PP próximos ao basal quando comparado com o grupo solução salina, provavelmente devido à diferença na meia vida do HES e da solução salina no espaço intravascular. / Background: Pulse pressure variation (PPV), have been shown to be useful tools to indicate fluid responsiveness in clinical and experimental studies. However, this parameter has not been adequately explored in situations of acute variation of blood viscosity, as happens in acute normovolemic hemodilution (ANH). The purpose of this research was to compare the behavior of PPV in a porcine model of ANH replaced with either normal saline or starch. Methods: Twenty one pigs 32Kg were anesthetized and randomly allocated in three groups: HES, blood removal was replaced with 6% hydroxyethyl starch; NS, normal saline was utilized as fluid replacement, and CONTROL, animals remained anesthetized without any intervention. Hemodynamic parameters were measured at baseline (T0), middle of ANH (T1), immediately after ANH (T2), 1h and 2h after ANH (T3 and T4 respectively), and immediately and 1h after blood re-infusion (T5,T6). Data were submitted to analysis of variance for repeated measures followed by Tukey test or Friedman test followed by Mann-Whitney test when appropriate. P<0.05 was considered statistically significant. Results: After ANH, dynamic parameters of fluid responsiveness, herein represented by PPV, presented different response when animals were treated with either starch (6,1 ± 2,2) or saline (14,1 ± 3,4). Besides, static parameters: pulmonary artery wedge pressure (HES 11 ± 3; 8 ± 3) and central venous pressure (HES 8 ± 2; NS 7 ± 4) presented contradictory values when compared to PPV. Conclusion: During ANH process colloids restored PPV values to baseline when compared o to normal saline, probably due to a difference in half-lives of HES and normal saline in the intravascular space.
104

Diversidade beta e funcional do zooplâncton em lagoas marginais com conectividade hidrológica com um rio tropical

Coelho, Paula Nunes January 2020 (has links)
Orientador: Raoul Henry / Resumo: As lagoas marginais são habitats lênticos, laterais ao rio, que podem manter comunicação permanente ou não com o rio. Nesses ecossistemas é encontrada elevada biodiversidade aquática, inclusive de zooplâncton. O objetivo deste estudo foi verificar diferenças na estrutura da comunidade zooplanctônica em lagoas marginais com diferentes níveis de conectividade hidrológica, por meio dos atributos ecológicos (riqueza, abundância, diversidade beta e funcional). Foi analisada a influência da conectividade hidrológica na comunidade de Cladocera e Rotifera em seis lagoas marginais antes e após um pulso de inundação do rio Paranapanema. Os resultados mostram que a estrutura da comunidade de Cladocera e Rotifera tende a ser mais distinta após o pulso de inundação. A diversidade beta foi mais elevada nas lagoas isoladas e na lagoa conectada que possui alta compartimentalização. Outro tema abordado diz respeito à analise da distribuição de Rotifera em um gradiente longitudinal da zona litorânea e envolvendo também a zona pelágica de uma lagoa marginal colonizada por macrófitas, por meio da diversidade taxonômica e funcional. A diversidade taxonômica foi maior na região de ecótono (transição da zona pelágica e litorânea) enquanto a diversidade funcional foi mais elevada na zona litorânea da lagoa. Neste estudo, também foi descrito como os microcrustáceos estão distribuídos em um transecto horizontal da zona litorânea e pelágica de uma lagoa marginal. A comunidade de microcrustáceos foi div... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The marginal lakes are lentic habitats, lateral to the river, that can maintain permanent communication or not with the river. High aquatic biodiversity is found in these ecosystems, including zooplankton. The aim of this study was to o verify differences in the structure of the zooplankton community in marginal lakes with different levels of hydrological connectivity, through ecological attributes (richness, abundance, beta and functional diversity). The influence of hydrological connectivity in the community of Cladocera and Rotifera in six marginal lakes was analyzed before and after the Paranapanema River pulse flood. The beta diversity was higher in isolated lakes and in connected lakes, which has high compartmentalization. Another topic addressed concerns the analysis of the distribution of Rotifera in a longitudinal gradient of the littoral zone and also involving the pelagic zone of a marginal lake colonized by macrophytes, through taxonomic and functional diversity. Taxonomic diversity was greater in the ecotone region (transition from the pelagic and littoral zone) while the functional diversity was higher in the littoral zone of the lake. In this study, it was also described how microcrustaceans are distributed in a horizontal transect of the littoral and pelagic zone of a marginal lake. The microcrustacean community was divided into six functional groups, with a predominance of the G2 group (bosminids) in the lake. Macrophytes had a strong influence on variations ... (Complete abstract click electronic access below) / Doutor
105

Estimação do sinal glotal para padrões acústicos de doenças da laringe / not available

Guerra, Aparecida de Cássia 03 May 2005 (has links)
Muitas pesquisas tem sido feitas em processamento digital de sinais (PDS) na tentativa de se avaliar o sinal de fala para diagnosticar doenças da laringe. Medidas acústicas têm sido propostas de forma a avaliar indiretamente o trato glotal por meio do sinal de voz coletado através de microfone convencional. Para isso, o modelo paramétrico Liljencrants-Fant (LF) foi desenvolvido para representar o sinal glotal em condições normais e patológicas. Tais parâmetros apresentam vantagens sobre medidas acústicas por possuírem características fisiológicas reais das pregas vocais. Assim, podendo ser empregados para identificação de doenças da laringe. Além da estimação dos parâmetros LF, no domínio do tempo (parâmetros T), a forma de onda da derivativa glotal também pôde ser quantificada através dos parâmetros identificados na literatura por parâmetros R (Rd, Ra, Rk e Rg), parâmetros quocientes Q (SQ, OQ, CQ, AQ e NAQ), parâmetros B1 e B2 que são as extensões de bandas do pulso derivativo LF, e o parâmetro ece, que relaciona os parâmetros &#946 e Ta. Os parâmetros B1 e B2 e ece apesar de serem propostos na literatura, não são encontrados resultados diferentes a essas duas medidas. Os resultados mostraram que os parâmetros B não foram confiáveis na discriminação entre as vozes, por outro lado, o parâmetro ece mostrou-se ser opção na discriminação entre as vozes normais, nódulo e Reinke. O objetivo deste trabalho é direcionar a atenção sobre o sinal glotal, estimando-o automaticamente mediante técnicas de PDS aplicadas ao sinal de fala, visando extrair parâmetros que identifiquem as condições normais e patológicas da laringe. Por fim foram propostos os parâmetros TRp e TRs, visando dissociar os efeitos de primeira ordem dos de ordem superior na fase de retorno do pulso glotal com a finalidade de estimar a real não-linearidade do sub-sistema glotal, retratando as condições normais e patológicas da laringe. Por fim foram propostos os parâmetros TRp e TRs, visando dissociar os efeitos de primeira ordem dos de ordem superior na fase de retorno do pulso glotal com a finalidade de estimar a real não-linearidade do sub-sistema glotal, retratando as condições fisiológicas do movimento das pregas vocais. Com um nível de confiança de 95%, o parâmetro de primeira ordem (TRp) é efetivo na discriminação do Edema de Reinke, porém mostrou-se ineficaz na detecção do nódulo. Em relação ao parâmetro de ordem superior, conclui-se que o TRs é um excelente detetor de vozes patológicas (nódulo e Edema de Reinke), porém não é capaz de discriminar as patologias. / Many researches has been conducted in digital signal processing (DSP) atempting to evaluate the physiological conditions of larynx. Acoustical parameters have been proposed to evaluate the glotal tract from voice signal. One technique proposed is the Liljencrants-Fant model (LF) developed to represent normal and pathologic conditions of the larynx. Those parameters compare favourably as far as real physiologic characteristic of vocal folds is concerned. So, a primary use of the model is the larynx pathologic identification. Beyond LF parameters estimation, (T parameters in the time domain), the waveform of glotal pulse derivative also can be quantified through, R parameters (Rd, Ra, Rk and Rg), quocient parameters (SQ, OQ, CQ, AQ and NAQ), B parameters (B1 and B2) that are band extension of the LF glotal pulse derivative and the ece parameter that in fact, is a relationship between &#946 and Ta. Although proposed in the literature, no results are found, related to B and ece parameters. Our founds show that B parameters do not present good results in voice discrimination, however, ece parameter seems to be good option to discriminate normal voice, nodulo and Reinke edema. The main purpose of this work is to estimate the glotal signal from the voice signal using DSP techniques in order to obtain parameters that identifies the physiological larynx condition. In order to estimate the shape of return phase of glotal pulse, twoparameters have been proposed in this work. The first one evaluates the pulse (TRp, in other words, the first order component of the return phase. The second is responsible to evaluate superior orders components of the return phase (TRs), i.e, the non-linear component of the glotal pulse. With 95% of confidence level, TRp is effective in Reinke edema discrimination however it is inefficient for nodule e dection. By the other hand, the TRs parameter works well to detect pathologic voice however is unable to discriminated them.
106

Influência da anodização pulsada nas propriedades da alumina anódica porosa (AAP) / Influence of pulsed anodization on the properties of porous anodic alumina (AAP)

Santos, Caio Guilherme Pereira dos 27 April 2017 (has links)
Submitted by Caio Santos (c.dehly@gmail.com) on 2017-10-26T20:56:53Z No. of bitstreams: 2 Dissertação_Caio.pdf: 6450967 bytes, checksum: 9c0ad5f1b63e4ef97562046030ba0696 (MD5) Carta_Comprovante.pdf: 679811 bytes, checksum: b230eed541e4ff4ea1205d79507474d1 (MD5) / Approved for entry into archive by Milena Rubi ( ri.bso@ufscar.br) on 2017-11-10T12:12:33Z (GMT) No. of bitstreams: 2 Dissertação_Caio.pdf: 6450967 bytes, checksum: 9c0ad5f1b63e4ef97562046030ba0696 (MD5) Carta_Comprovante.pdf: 679811 bytes, checksum: b230eed541e4ff4ea1205d79507474d1 (MD5) / Approved for entry into archive by Milena Rubi ( ri.bso@ufscar.br) on 2017-11-10T12:12:54Z (GMT) No. of bitstreams: 2 Dissertação_Caio.pdf: 6450967 bytes, checksum: 9c0ad5f1b63e4ef97562046030ba0696 (MD5) Carta_Comprovante.pdf: 679811 bytes, checksum: b230eed541e4ff4ea1205d79507474d1 (MD5) / Made available in DSpace on 2017-11-10T12:13:12Z (GMT). No. of bitstreams: 2 Dissertação_Caio.pdf: 6450967 bytes, checksum: 9c0ad5f1b63e4ef97562046030ba0696 (MD5) Carta_Comprovante.pdf: 679811 bytes, checksum: b230eed541e4ff4ea1205d79507474d1 (MD5) Previous issue date: 2017-04-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Porous anodic alumina can be obtained, in addition to conventional methods such as potentiostatic and galvanostatic, or by pulsed method. Among these are the methods of discontinuous pulse, hybrid pulse and polarized pulse methods. The structures formed by these methods can be applied to sensors and photonic materials. In this work the influences of the pulse parameters for the porous anodic alumina were investigated by polarized pulse potentiostatic anodization. Data analysis was presented from the duty cycle seen in the literature, which provides important information about the structure formed for the applied conditions and, in addition, new ways of analyzing the data related to the pulse, such as the analysis of the potential difference and the pulse frequency, this latter complementing the analysis of the duty cycle. As a result it was possible to observe that the porous anodic alumina thickness obtained is proportional to the duty cycle applied, where the higher duty cycle, the greater the thickness obtained. From the potential difference, the differences in the morphological and optical parameters could be analyzed by the influence of the negative minimum voltage applied during the pulsed anodization. The pulse frequency, also discussed in this work, was used to analyze different pulse periods for the same duty cycle, demonstrating that can be obtained structures with different values by varying the value of the pulse frequency. For the porosity calculation, an application was developed that helped to obtain the pore distance, which is one of the variables used to calculate the porosity. With the porosity values, the effective refractive index of each sample was calculated to find the effective optical thickness (EOT) and, finally, the thickness of the obtained anodic alumina film. / A alumina anódica porosa pode ser obtida, além dos métodos convencionais como potenciostático e galvanostático, ou por métodos pulsados. Dentre estes destacam-se os métodos de pulso descontínuo, pulso híbrido e pulso polarizado. As estruturas formadas por estes métodos podem ser aplicadas em sensores e materiais fotônicos. Neste trabalho foram investigadas as influências dos parâmetros de pulso para a obtenção da alumina anódica porosa pelo método de anodização potenciostática com pulso polarizado. Foram apresentadas análises de dados a partir do ciclo de trabalho visto na literatura, onde traz importantes informações sobre a estrutura formada para as condições aplicadas e, além disto, novas formas de analisar os dados referentes aos pulsos, como a análise a partir da diferença de potencial e a frequência de pulso, este último complementando a análise do ciclo de trabalho. Como resultado foi possível observar que a espessura de alumina anódica porosa obtida é proporcional ao ciclo de trabalho aplicado, onde quanto maior o ciclo de trabalho, maior será a espessura obtida. A partir da diferença de potencial pôde-se analisar as diferenças nos parâmetros morfológicos e ópticos pela influência da tensão mínima negativa aplicada durante a anodização pulsada. A frequência de pulso, também abordada neste trabalho, foi utilizada para analisar diferentes períodos de pulsos para o mesmo ciclo de trabalho, demonstrando que variando o valor da frequência de pulso pode-se obter estruturas com valores distintos. Para o cálculo da porosidade foi desenvolvido um aplicativo que auxiliou na obtenção da distância entre poros, que é uma das variáveis utilizadas para o cálculo da porosidade. E com os valores de porosidade foi calculado o índice de refração efetivo de cada amostra para encontrar a sua espessura óptico efetivo (EOT, do inglês Effective Optical Thickness) e, por fim, a espessura do filme de alumina anódica obtido.
107

Estimação do sinal glotal para padrões acústicos de doenças da laringe / not available

Aparecida de Cássia Guerra 03 May 2005 (has links)
Muitas pesquisas tem sido feitas em processamento digital de sinais (PDS) na tentativa de se avaliar o sinal de fala para diagnosticar doenças da laringe. Medidas acústicas têm sido propostas de forma a avaliar indiretamente o trato glotal por meio do sinal de voz coletado através de microfone convencional. Para isso, o modelo paramétrico Liljencrants-Fant (LF) foi desenvolvido para representar o sinal glotal em condições normais e patológicas. Tais parâmetros apresentam vantagens sobre medidas acústicas por possuírem características fisiológicas reais das pregas vocais. Assim, podendo ser empregados para identificação de doenças da laringe. Além da estimação dos parâmetros LF, no domínio do tempo (parâmetros T), a forma de onda da derivativa glotal também pôde ser quantificada através dos parâmetros identificados na literatura por parâmetros R (Rd, Ra, Rk e Rg), parâmetros quocientes Q (SQ, OQ, CQ, AQ e NAQ), parâmetros B1 e B2 que são as extensões de bandas do pulso derivativo LF, e o parâmetro ece, que relaciona os parâmetros &#946 e Ta. Os parâmetros B1 e B2 e ece apesar de serem propostos na literatura, não são encontrados resultados diferentes a essas duas medidas. Os resultados mostraram que os parâmetros B não foram confiáveis na discriminação entre as vozes, por outro lado, o parâmetro ece mostrou-se ser opção na discriminação entre as vozes normais, nódulo e Reinke. O objetivo deste trabalho é direcionar a atenção sobre o sinal glotal, estimando-o automaticamente mediante técnicas de PDS aplicadas ao sinal de fala, visando extrair parâmetros que identifiquem as condições normais e patológicas da laringe. Por fim foram propostos os parâmetros TRp e TRs, visando dissociar os efeitos de primeira ordem dos de ordem superior na fase de retorno do pulso glotal com a finalidade de estimar a real não-linearidade do sub-sistema glotal, retratando as condições normais e patológicas da laringe. Por fim foram propostos os parâmetros TRp e TRs, visando dissociar os efeitos de primeira ordem dos de ordem superior na fase de retorno do pulso glotal com a finalidade de estimar a real não-linearidade do sub-sistema glotal, retratando as condições fisiológicas do movimento das pregas vocais. Com um nível de confiança de 95%, o parâmetro de primeira ordem (TRp) é efetivo na discriminação do Edema de Reinke, porém mostrou-se ineficaz na detecção do nódulo. Em relação ao parâmetro de ordem superior, conclui-se que o TRs é um excelente detetor de vozes patológicas (nódulo e Edema de Reinke), porém não é capaz de discriminar as patologias. / Many researches has been conducted in digital signal processing (DSP) atempting to evaluate the physiological conditions of larynx. Acoustical parameters have been proposed to evaluate the glotal tract from voice signal. One technique proposed is the Liljencrants-Fant model (LF) developed to represent normal and pathologic conditions of the larynx. Those parameters compare favourably as far as real physiologic characteristic of vocal folds is concerned. So, a primary use of the model is the larynx pathologic identification. Beyond LF parameters estimation, (T parameters in the time domain), the waveform of glotal pulse derivative also can be quantified through, R parameters (Rd, Ra, Rk and Rg), quocient parameters (SQ, OQ, CQ, AQ and NAQ), B parameters (B1 and B2) that are band extension of the LF glotal pulse derivative and the ece parameter that in fact, is a relationship between &#946 and Ta. Although proposed in the literature, no results are found, related to B and ece parameters. Our founds show that B parameters do not present good results in voice discrimination, however, ece parameter seems to be good option to discriminate normal voice, nodulo and Reinke edema. The main purpose of this work is to estimate the glotal signal from the voice signal using DSP techniques in order to obtain parameters that identifies the physiological larynx condition. In order to estimate the shape of return phase of glotal pulse, twoparameters have been proposed in this work. The first one evaluates the pulse (TRp, in other words, the first order component of the return phase. The second is responsible to evaluate superior orders components of the return phase (TRs), i.e, the non-linear component of the glotal pulse. With 95% of confidence level, TRp is effective in Reinke edema discrimination however it is inefficient for nodule e dection. By the other hand, the TRs parameter works well to detect pathologic voice however is unable to discriminated them.
108

[en] HIGH SENSITIVITY TRANSDUCERS FOR MEASURING ARTERIAL PULSE WAVE VELOCITY, BASED ON IMPEDANCE PHASE READINGS OF GMI SENSORS / [pt] TRANSDUTORES DE ALTA SENSIBILIDADE DESTINADOS À MEDIÇÃO DA VELOCIDADE DA ONDA DE PULSO ARTERIAL, BASEADOS NA LEITURA DA FASE DA IMPEDÂNCIA DE SENSORES GMI

LIZETH STEFANÍA BENAVIDES CABRERA 16 November 2021 (has links)
[pt] A velocidade da onda de pulso (VOP) tem sido identificada como o padrão-ouro para avaliação da rigidez arterial e, recentemente, vem sendo reconhecida como um importante indicador no diagnóstico e tratamento de doenças cardiovasculares. Atualmente, já existem dispositivos comerciais capazes de efetuar a medição da VOP, entretanto, ainda exigem um investimento financeiro significativo e alguns requerem um treinamento especializado para seu correto uso. Os, transdutores de pressão atuais são majoritariamente baseados em sensores piezoresistivos, piezoelétricos e capacitivos. Entretanto, pesquisas recentes demostraram que transdutores de pressão que utilizam sensores magnéticos baseados na magnetoimpedância gigante (GMI) apresentam elevada sensibilidade. Tendo em vista que a VOP é um importante indicador do risco de distúrbios cardiovasculares, e considerando os potenciais beneficios dos sensores GMI em relação às demais alternativas, esta tese de doutorado buscou utilizar-se destes elementos sensores a fim de desenvolver um sistema de medição portátil, não-invasivo, de baixo custo, acessível e simples de usar, capaz de efetuar a medição da VOP. Neste intuito, foram desenvolvidos transdutores de alta sensibilidade, baseados nas características de fase da impedância de sensores de Magnetoimpedância Gigante, destinados à medição da velocidade da onda de pulso arterial. A fim de se otimizar as características de desempenho dos transdutores, foram realizadas avaliações teórico-computacionais dos transdutores na configuração em malha aberta e fechada, bem como ensaios experimentais dos protótipos projetados. As caracterizações e ensaios experimentais realizados com o transdutor de pressão em malha aberta resultaram em uma sensibilidade de 59,6 mV/kPa, e resolução de 192,8 Pa para uma média de 30 amostras, na banda de passagem de 1000 Hz. Por outro lado, a configuração em malha fechada apresentou uma sensibilidade de 54,2 mV/kPa, e resolução de 206,0 Pa para uma média de 30 amostras, na banda de passagem de 32 Hz. Tendo em vista os valores de sensibilidade e resolução obtidos, propõe-se empregar o sistema de transdução de pressão que incorpora uma câmara incompressível para amplificação mecânica, na medição de ondas de pulso arterial. Neste protótipo, uma pequena membrana semirrígida localizada na superfície da câmara incompressível é posicionada sobre a superfície da pele, próxima à artéria de interesse. Deste modo, pequenas mudanças de pressão na superfície da pele, causadas pela onda de pulso arterial, provocam uma variação do campo magnético sobre o elemento sensor. Por outra parte, devido à alta sensibilidade apresentada pelo transdutor magnetico (magnetômetro GMI) na configuração de malha aberta (0,2 mV/nT) e de malha fechada (0,19 mV/nT), estes foram usados para medir diretamente a forma de onda do pulso arterial, sem utilizar uma câmara incompressível para transdução mecânica. Nesta medição, considerando a adequada resolução espacial para as demandas anatômicas, utiliza-se um pequeno marcador magnético, envolto por uma fita adesiva hipoalergênica e flexível, aderida á região da pele sobre a artéria de interesse, e aproxima-se o sensor magnético GMI da superfície da pele onde o marcador foi colocado. Finalmente, as configurações propostas foram analisadas e comparadas, a fim de se identificar aquela com melhor desempenho, a qual foi utilizada para medição da VOP. Como o estudo envolve o registro da onda de pulso em participantes da pesquisa, o projeto foi submetido à apreciação e aprovado pela Comissão da Câmara de Ética em Pesquisa da Pontifícia Universidade Católica do Rio de Janeiro (PUC-Rio) 045/2020 – Protocolo 83/2020. Espera-se que o dispositivo desenvolvido contribua para o avanço tecnológico do ferramental utilizado no setor da saúde. / [en] Pulse wave velocity (PWV) is considered the gold standard for assessing arterial stiffness and recently, it has been recognized as an important indicator in the diagnosis and treatment of cardiovascular disease. Currently, there are commercial devices capable of measuring PWV, however, significant investments are required and some devices requires specialized training for their correct use. Conventional pressure-sensing devices are mainly based on piezoresistive, piezoelectric and capacitive sensors. Recent investigations, however, show that pressure transducer using magnetic sensors based on the giant Magnetoimpedance (GMI) present high-sensitivity. Considering that, PWV is a significant risk factor for future cardiovascular disease and in view of some of the advantages of GMI sensors in relation to another sensing technologies, this doctoral thesis aims to develop a portable measurement system, non-invasive, low-cost, accessible and simple to use, capable of measuring PWV. For this purpose, we have developed a high-sensitivity transducers based on the impedance phase characteristics of GMI sensors, for measuring the arterial pulse wave velocity. In order to improve the performance characteristics of the transducers, computational and theoretical analysis in open and closed loop configuration were performed. The characterizations and experimental tests performed with the open-loop pressure transducer resulted in a sensitivity of 59.6 mV/kPa, and resolution of 192.8 Pa for an average of 30 samples, in the 1000 Hz passband. On the other hand, the closed-loop configuration presented a sensitivity of 54.2 mV/kPa, and a resolution of 206.0 Pa for an average of 30 samples, in the 32 Hz passband. In view of the considerable sensitivity and resolution obtained, it is proposed to employ a pressure transduction system that incorporates an incompressible chamber for mechanical amplification, in the measurement of arterial pulse waves. In this prototype, a small semi-rigid membrane located on the surface of the incompressible chamber is positioned over the surface of the skin, close to the artery of interest. In this way, small pressure changes on the skin surface, caused by the arterial pulse wave, cause a variation of the magnetic field on the sensing element. On the other hand, due to the high sensitivity presented by the magnetic transducer (GMI magnetometer) in the open-loop (0.2 mV/nT) and closed-loop (0.19 mV/nT) configurations, they were used to measure the shape pulse waveform without using an incompressible chamber for mechanical transduction. In this test, considering the adequate spatial resolution for the anatomical demands, a small magnetic marker is used, the magnetic marker is attached to the skin region over the artery of interest, and the GMI magnetic sensor is approached near the marker placed of the skin surface. Finally, the proposed configurations were analyzed and compared in order to identify the one with the best performance, which was used to measure PWV. As the study involves recording the pulse wave in research participants, the project was submitted for consideration and approved by the Research Ethics Committee of the Pontifical Catholic University of Rio de Janeiro (PUC-Rio) 045/2020 – Protocol 83/2020. It is expected that the device developed will contribute to the technological advancement of the tools used in the health sector.
109

Análise in vitro da morfologia e da resistência de união da resina composta à dentina erodida e irradiada com laser de Er:YAG com largura de pulso super curta / In vitro analysis of morphology and bond strength of composite resin to dentin eroded and irradiated with a super short pulse Er:YAG laser

Cersosimo, Maria Cecília Pereira 29 January 2016 (has links)
Lesões dentais por erosão têm sido cada vez mais presentes na prática clínica. A restauração direta com resina composta é uma das opções de tratamento para lesões severas, em que há comprometimento estético/funcional. Com o aprimoramento da tecnologia, a utilização do laser para pré-tratamento da superfície dentinária, antes do condicionamento ácido, tem sido considerada como método alternativo para melhorar a adesão das resinas compostas às superfícies erodidas. Assim, o objetivo deste estudo in vitro foi avaliar a influência da irradiação com laser de Er:YAG (2,94 ?m), de pulso super-curto, na adesão da resina composta à superfície dentinária erodida. Quarenta e seis discos de dentina foram obtidos a partir de 46 dentes terceiros molares humanos. A dentina oclusal planificada de 40 molares humanos teve metade de sua face protegida com fita UPVC (dentina hígida), enquanto na outra metade foi produzida uma lesão de erosão através da ciclagem em ácido cítrico (0,05 M, pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Metade das amostras foi irradiada com o laser de Er:YAG (50 ?s, 2 Hz, 80 mJ, 12,6 J/cm2) e a outra não (grupo controle). Em cada grupo de tratamento (laser ou controle) (n=10), um sistema adesivo autocondicionante foi utilizado e, então, confeccionados 2 cilindros de resina composta, tanto do lado erodido como no hígido (total de 4 cilindros), os quais foram submetidos à avaliação da Resistência de União através do ensaio de microcisalhamento (1 mm/min), após armazenamento em saliva artificial por 24 h. A análise do padrão de fratura foi realizada em microscópio óptico (40x). Por meio da Microscopia Eletrônica de Varredura (MEV), a morfologia das superfícies dentinárias hígida e submetida ao desafio erosivo, antes e após o tratamento com laser de Er:YAG (n=3), foi avaliada. Os valores obtidos de resistência de união (MPa) foram submetidos ao teste ANOVA e de comparações múltiplas de Tukey (p<0,05) e as análises das eletromicrografias foram feitas de forma descritiva. A análise morfológica da superfície mostrou alterações significativas na dentina hígida irradiada e na submetida à ciclagem erosiva, irradiada ou não. Quanto à resistência de união, houve diferença entre os 4 substratos analisados, sendo: dentina hígida irradiada (12,77±5,09 A), dentina hígida não irradiada (9,76±3,39 B), dentina erodida irradiada (7,62±3,39 C) e dentina erodida não irradiada (5,12±1,72 D). Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que a erosão reduz a adesão em dentina e que o tratamento da superfície dentinária com laser de Er:YAG de largura de pulso super curta aumenta a adesão no substrato erodido ou hígido. / Dental erosion injuries have been increasingly present in clinical practice. Direct restoration with composite resin is one of the treatment options for severe injuries, where there is aesthetic/functional impairment. With the improvement of technology, laser-irradiation for pre-treatment of dentin before surface etching has been considered as an alternative method to improve the adhesion of composite resins to eroded surfaces. The objective of this in vitro study was to evaluate the influence of the irradiation with a super-short pulse Er:YAG (2.94 ?m) laser to the adhesion of composite resin to eroded dentin surface. Forty six dentin discs were obtained from 46 third molars. Forty samples of planned occlusal dentine, obtained from human molars, had half of their surface protected with plastic tape (sound dentin), while the other half was submitted to erosive cycles, consisted on immersion on citric acid (0.05 M, pH 2.3, 10 minutes, 6x/day) and supersaturated solution (pH 7.0, 60 minutes of acid attacks). Half of the samples was irradiated with the Er:YAG laser (50 ?s, 2 Hz, 80 mJ, 12.6 J/cm2) and the other was kept as control. In each treatment group (n = 10), a self-etching adhesive system was used and then two cylinders of composite resin were prepared, on both eroded and sound dentin (total of 4 cylinders). Microshear bond strength test was performed (1 mm/min), after 24 hours storage in artificial saliva. The analysis of the fracture pattern was determined by optical microscopy (40x). The morphology of sound and eroded dentin, before and after treatment with the Er:YAG laser (n = 3) was evaluated under Scanning Electron Microscopy (SEM). Bond strength values (MPa) were subjected to ANOVA and Tukey multiple comparisons test (p<0.05). The analyses of electron micrographs were made descriptively. Morphological analysis of the surface showed significant changes in irradiated and sound dentin subjected to erosive cycling. As for the bond strength, there were differences among the groups, as follows: sound dentin submitted to irradiation (12.77 ± 5.09 A), non-irradiated sound dentin (9.76 ± 3.39 B), eroded dentin submitted to irradiation (7 62 ± 3.39 C) and non-irradiated eroded dentin (5.12 ± 1.72 D). There was a predominance for the adhesive mode of failure. It was concluded that the erosion reduces the adhesion to dentin and that treating the dentin surface with a super-short-pulse Er:YAG laser increases adhesion to both eroded or sound dentin.
110

Modelagem de ondas ultrassônicas refletidas por superfícies de geometrias diversas. / Modeling for ultrasonics waves of reflected surfaces of various geometries.

Formigoni, Paulo Orestes 20 May 2011 (has links)
Neste trabalho são analisados os campos acústicos gerados por transdutores ultrassônicos planos e circulares, do tipo pistão plano, no modo pulso-eco, trabalhando como emissor e receptor de ondas, com freqüências de 1,6 MHz, 2,25 MHz e 5 MHz. As ondas emitidas por esses transdutores interagem com interfaces denominadas alvos, com diversas geometrias de superfícies, como planas e circulares, planas com cavidade do tipo alvéolo circular, e cone reto, todas compostas de alumínio e imersas em tanque com água. O campo acústico refletido varia de acordo com o tipo de geometria do alvo. Para essas analises foram produzidas e comparadas modelagens do campo acústico no software Matlab, por meio de dois modelos teóricos: método da resposta impulsiva e método da representação discreta. Foram analisados o tempo de computação produzido pelo método numérico com relação a discretização dos elementos de área do transdutor e do alvo, alem da influencia da conversão de modo nas respostas impulsivas simuladas para essas superfícies. Os resultados mostraram uma boa correlação entre os dois métodos teóricos, porem o de representação discreta possibilita o estudo em transdutores com geometria diferente do pistão plano, sem o uso de integrais complexas. As diferenças dos resultados experimentais e teóricos podem ser minimizadas por meio de uma escolha adequada da relação entre a discretização e comprimento de onda (Dx/), em que foi considerado um valor aceitável de erro relativo de 15% para Dx/ 0,68. Foi observado que o uso da conversão de modo na interface refletora influi apenas na amplitude do sinal de eco (atenuação) e não na forma do sinal. / This work deals with acoustic fields generated by ultrasonic broadband transducers as a planar circular piston, operating in pulse-echo mode, with frequencies of 1.6 MHz, 2.25 MHz and 5 MHz. The waves emitted by transducers interact with water-immersed aluminum targets of different geometries such as planar circular surfaces, concave circular cavity on plane surfaces, and right circular conical surfaces. The impulse response and the discrete representation methods were applied to model the echo responses, using the Matlab software. The influence of mode conversion over the simulated impulse responses for these surfaces was analyzed. The results show a good correlation between the two theoretical methods, but the discrete representation enables the study of arbitrary aperture transducers, with no need to solve complex integrals. The computational times of the discrete representation method was analyzed were respect to the spatial discretization of both the transducer aperture and the target. Experimental tests were carried out to validate the simulated results. Differences in experimental and theoretical results can be minimized by an appropriate choice of the discretization/wavelength ratio (Dx / ). A relative error of 15% was considered acceptable for Dx / 0,68. It was observed that the use of mode conversion at the reflected interface modifies only the amplitude of the echo signal (attenuation), but not its shape.

Page generated in 0.4381 seconds